Other products from "INSTRUMENTATION INDUSTRIES, INCORPORATED"
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 M996SH7710 SH 77-1 Oropharyngeal airway allows a fast and easy way to establish a patent airway by Oropharyngeal airway allows a fast and easy way to establish a patent airway by holding the tongue up and out of the way. Size - 40 mm. CAE Airway, Oropharyngeal, Anesthesiology SH 77-1 Oropharyngeal Airway
2 M996SH720 SH 7-2 SH 7-2 SH 7-2 Five-in-One Connector connects tubing with inside diameters from 3/16" to SH 7-2 Five-in-One Connector connects tubing with inside diameters from 3/16" to 7/16". Barbed edges on each step help to prevent disconnects. Single Patient Use BYX Tubing, Pressure And Accessories SH 7-2 Five-in-One Connector
3 M996SG1020 SG 102 SG 102 Reducing Adapter for use in breathing/ventilator circuit. - 10mm O.D. x 22mm I.D Reducing Adapter for use in breathing/ventilator circuit. - 10mm O.D. x 22mm I.D. Molded of polycarbonate. Reusable. CAI Circuit, Breathing (W Connector, Adaptor, Y Piece) 1 SG 102 Reducing Adapter
4 M996SG10100 SG 1010 SG 1010 General Adapter 10mm OD x 10mm OD. Fits components of neonatal ventilator circui General Adapter 10mm OD x 10mm OD. Fits components of neonatal ventilator circuits/CPAP systems. Molded of polysulfone. Reusable. CAI Circuit, Breathing (W Connector, Adaptor, Y Piece) 1 SG 1010 Adapter
5 M996SG0662N0 SG 066-2N The SG 066-2N 1 liter latex-free reservoir bag is intended to be used with the S The SG 066-2N 1 liter latex-free reservoir bag is intended to be used with the SG 066 Oxygen Enrichment Kit, while in use on certain ventilators to provide higher concentrations of oxygen to the patient by mixing room air with an oxygen source at the proximal airway. BTC Bag, Reservoir 1 SG 066-2N 1 liter latex-free reservoir bag
6 M996RTC23D0 RTC 23-D RTC 23-D The Instrumentation Industries, Inc. RTC 23-D is an actuator for intermittent de The Instrumentation Industries, Inc. RTC 23-D is an actuator for intermittent delivery of prescribed aerosol medication dispensed in metered dose inhalers. The RTC 23-D Adapter is intended for use only when connected to ventilator tubing or tracheal tubes. For use with metered dose inhaler canisters with standard size metal or plastic stems.The RTC 23-D Adapter is intended for Single Patient Reuse. This device is intended for sale by or on the order of a physician. CAF Nebulizer (Direct Patient Interface) 2 RTC 23-D Metered Dose Inhaler Adapter
7 M996RTC23A0 RTC 23-A RTC 23-A The Instrumentation Industries, Inc. RTC 23-A is an actuator for intermittent de The Instrumentation Industries, Inc. RTC 23-A is an actuator for intermittent delivery of prescribed aerosol medication dispensed in metered dose inhalers. The RTC 23-A Adapter is intended for use only when connected to ventilator tubing or tracheal tubes. For use with metered dose inhaler canisters with standard size metal or plastic stems.The RTC 23-A Adapter is intended for Single Patient Reuse. This device is intended for sale by or on the order of a physician. CAF Nebulizer (Direct Patient Interface) RTC 23-A Metered Dose Inhaler Adapter
8 M996PS54AL0 PS 54AL This reusable exhalation valve is designed for use with ventilators. The exhala This reusable exhalation valve is designed for use with ventilators. The exhalation valve prevents the inspired gases from escaping through the passage that will be made available to expired gases via an inflatable balloon. Also, the re-breathing of the expired gases are prevented by the balloon action. CBP Valve, Non-Rebreathing 2 PS 54AL Low Resistance Exhalation Valve with Water Trap
9 M996PS541A0 PS 54-1A This adapter connects to the exhalation valve for additional versatility. CBP Valve, Non-Rebreathing PS 54-1A Adapter for Exhalation Valves
10 M996PF15150 PF 1515 PF 1515 Straight Connector - 15mm ID x 15mm ID. Fits components of pediatric ventilator Straight Connector - 15mm ID x 15mm ID. Fits components of pediatric ventilator circuits. Molded of silicone rubber. Reusable. CAI Circuit, Breathing (W Connector, Adaptor, Y Piece) PF 1515 Straight Silicone Rubber Connector
11 M996PF10100 PF 1010 PF 1010 Straight Connector - 10mm ID x 10mm ID. Fits components of neonatal ventilator c Straight Connector - 10mm ID x 10mm ID. Fits components of neonatal ventilator circuits. Molded of silicone rubber. Reusable. CAI Circuit, Breathing (W Connector, Adaptor, Y Piece) PF 1010 Straight Silicone Rubber Connector
12 M996NS60TRR0 NS 60-TRR NS 60-TRR The Instrumentation Industries, Inc. NS Series Negative Inspiratory Force (NIF) The Instrumentation Industries, Inc. NS Series Negative Inspiratory Force (NIF) Meters are devices used to measure and monitor patient inspiratory effort. During use the NIF Meter is attached to the patient airway at a point that provides optimal readings of patient respiratory effort. Federal law restricts these devices to sale by or on the order of a physician. BXR Meter, Airway Pressure (Inspiratory Force) 2 NS 60-TRR Negative Inspiratory Force (NIF) Meter
13 M996NS60TBR0 NS 60-TBR NS 60-TBR The Instrumentation Industries, Inc. NS Series Negative Inspiratory Force (NIF) The Instrumentation Industries, Inc. NS Series Negative Inspiratory Force (NIF) Meters are devices used to measure and monitor patient inspiratory effort. During use the NIF Meter is attached to the patient airway at a point that provides optimal readings of patient respiratory effort. Federal law restricts these devices to sale by or on the order of a physician. BXR Meter, Airway Pressure (Inspiratory Force) 2 NS 60-TBR Negative Inspiratory Force (NIF) Meter
14 M996NS30PBR0 NS 30-PBR NS 30-PBR The Instrumentation Industries, Inc. NS Series Negative Inspiratory Force (NIF) The Instrumentation Industries, Inc. NS Series Negative Inspiratory Force (NIF) Meters are devices used to measure and monitor patient inspiratory effort. During use the NIF Meter is attached to the patient airway at a point that provides optimal readings of patient respiratory effort. Federal law restricts these devices to sale by or on the order of a physician. BXR Meter, Airway Pressure (Inspiratory Force) 2 NS 30-PBR Negative Inspiratory Force (NIF) Meter
15 M996NS30115UL0 NS 30-115-UL This reusable exhalation valve is designed for use with ventilators. The exhala This reusable exhalation valve is designed for use with ventilators. The exhalation valve prevents the inspired gases from escaping through the passage that will be made available to expired gases via an inflatable balloon. Also, the re-breathing of the expired gases are prevented by the balloon action. CBP Valve, Non-Rebreathing 2 NS 30-115-UL Low Resistance Exhalation Valve
16 M996MT1000 MT 100 MT 100 The MT 100 Oxygen Sensor Activation System is designed for use with the Maxtec H The MT 100 Oxygen Sensor Activation System is designed for use with the Maxtec Handi Oxygen Analyzer. By utilizing a check valve in the Tee Adapter, an airtight seal is maintained in-line, unless actuated by the stem of the activator. This system therefore provides the capability of rapid monitoring of the patient breathing environment without the inconvenience of breaking the ventilation circuit. CCL Analyzer, Gas, Oxygen, Gaseous-Phase 2 MT100 Oxygen Sensor Activation System
17 M996MS101400 MS 101-40 MS 101-40 The MS 101-40 Pressure Adapter: Dimensions - Barbed Port fits 3/16" tubing x 1 The MS 101-40 Pressure Adapter: Dimensions - Barbed Port fits 3/16" tubing x 15mm I.D. x 15mm I.D. BYX Tubing, Pressure And Accessories 1 MS 101-40 Pressure Adapter
18 M996KC6PA0 KC 6PA KC 6PA The KC 6PA Pressure Adapter: Dimensions - Capped Luer Lock port x 15mm I.D. x 15mm I.D. BYX Tubing, Pressure And Accessories KC 6PA Pressure Adapter
19 M996KC18901O0 KC 18901-O KC 18901-O 90 degree Elbow Connector with Barbed Port that fits 3/16" ID tubing - 15mm ID/2 90 degree Elbow Connector with Barbed Port that fits 3/16" ID tubing - 15mm ID/22mm OD x15mm OD. Molded of polycarbonate. Reusable. CAI Circuit, Breathing (W Connector, Adaptor, Y Piece) KC 18901-O Elbow Connector
20 M996KC1452230D0 KC 145-2230D KC 145-2230D The KC 145-2230D Hose Connector: Dimensions - 22mm I.D/30mm O.D. x tapered barb The KC 145-2230D Hose Connector: Dimensions - 22mm I.D/30mm O.D. x tapered barb adapter. This is a single patient use device BYX Tubing, Pressure And Accessories KC 145-2230D Hose Connector
21 M996KC060P220 KC 060-P22 KC 060-P22 - 60" length Reusable Ventilator Tubing (15mm ID tube with 22mm ID cu KC 060-P22 - 60" length Reusable Ventilator Tubing (15mm ID tube with 22mm ID cuffs). Cream-colored polyester elastomer tube with cream-colored silicone rubber cuffs. BZO Set, Tubing And Support, Ventilator (W Harness) 1 KC 060-P22 - Reusable Ventilator Tubing (15mm tube with 22mm ID cuffs)
22 M996KC060P0 KC 060-P KC 060-P, 15mm ID, 60" length - Reusable Ventilator Tubing - polyester elastome KC 060-P, 15mm ID, 60" length - Reusable Ventilator Tubing - polyester elastomer tube with silicone rubber cuffs BZO Set, Tubing And Support, Ventilator (W Harness) 1 KC 060-P - 15mm ID Reusable Ventilator Tubing
23 M996KC060GG0 KC 060-GG KC 060-GG, 22mm ID, 60" length - Reusable Ventilator Tubing - gray-colored poly KC 060-GG, 22mm ID, 60" length - Reusable Ventilator Tubing - gray-colored polyester elastomer tube with gray silicone rubber cuffs BZO Set, Tubing And Support, Ventilator (W Harness) 1 KC 060-GG - 22mm ID Reusable Ventilator Tubing
24 M996KC060B0 KC 060-B KC 060-B, 22mm ID, 60" length - Reusable Ventilator Tubing - gray-colored polye KC 060-B, 22mm ID, 60" length - Reusable Ventilator Tubing - gray-colored polyester elastomer tube with blue silicone rubber cuffs BZO Set, Tubing And Support, Ventilator (W Harness) 1 KC 060-B - 22mm ID Reusable Ventilator Tubing
25 M996KC0420 KC 042 KC 042, 22mm ID, 42" length - Reusable Ventilator Tubing - polyester elastomer KC 042, 22mm ID, 42" length - Reusable Ventilator Tubing - polyester elastomer tube with silicone rubber cuffs BZO Set, Tubing And Support, Ventilator (W Harness) 1 KC 042 - 22mm ID Reusable Ventilator Tubing
26 M996KC04030 KC 040-3 KC 040-3 - 22mm ID, 40" length - Reusable Ventilator Tubing - cream-colored poly KC 040-3 - 22mm ID, 40" length - Reusable Ventilator Tubing - cream-colored polyester elastomer tube with Integral Cuffs. Recommended usage: 50 sanitizing cycles. Actual cycle life depends on end-user handling precautions. BZO Set, Tubing And Support, Ventilator (W Harness) 1 KC 040-3 22mm ID Ventilator Tubing with Integral Cuffs
27 M996KC036P0 KC 036-P KC 036-P, 15mm ID, 36" length - Reusable Ventilator Tubing - polyester elastome KC 036-P, 15mm ID, 36" length - Reusable Ventilator Tubing - polyester elastomer tube with silicone rubber cuffs BZO Set, Tubing And Support, Ventilator (W Harness) 1 KC 036-P - 15mm ID Reusable Ventilator Tubing
28 M996KC036N0 KC 036-N KC 036-N, 10mm ID, 36" length - Reusable Ventilator Tubing - polyester elastome KC 036-N, 10mm ID, 36" length - Reusable Ventilator Tubing - polyester elastomer tube with silicone rubber cuffs BZO Set, Tubing And Support, Ventilator (W Harness) 1 KC 036-N - 10mm ID Reusable Ventilator Tubing
29 M996KC036BC0 KC 036-BC KC 036-BC, 22mm ID, 36" length - Reusable Ventilator Tubing - cream-colored pol KC 036-BC, 22mm ID, 36" length - Reusable Ventilator Tubing - cream-colored polyester elastomer tube with blue silicone rubber cuffs BZO Set, Tubing And Support, Ventilator (W Harness) 1 KC 036-BC - 22mm ID Reusable Ventilator Tubing
30 M996KC0365N0 KC 036-5N KC 036-5N - 36" length, 10mm ID, Clear Ventilator Tubing with Integral Cuffs. F KC 036-5N - 36" length, 10mm ID, Clear Ventilator Tubing with Integral Cuffs. For Single Patient Use. BZO Set, Tubing And Support, Ventilator (W Harness) 1 KC 036-5N 10mm ID Ventilator Tubing with Integral Cuffs
31 M996KC0360 KC 036 KC 036, 22mm ID, 36" length - Reusable Ventilator Tubing - polyester elastomer KC 036, 22mm ID, 36" length - Reusable Ventilator Tubing - polyester elastomer tube with silicone rubber cuffs BZO Set, Tubing And Support, Ventilator (W Harness) 1 KC 036 - 22mm ID Reusable Ventilator Tubing
32 M996KC030P0 KC 030-P KC 030-P, 15mm ID, 30" length - Reusable Ventilator Tubing - polyester elastome KC 030-P, 15mm ID, 30" length - Reusable Ventilator Tubing - polyester elastomer tube with silicone rubber cuffs BZO Set, Tubing And Support, Ventilator (W Harness) 1 KC 030-P - 15mm ID Reusable Ventilator Tubing
33 M996KC030N0 KC 030-N KC 030-N, 10mm ID, 30" length - Reusable Ventilator Tubing - polyester elastome KC 030-N, 10mm ID, 30" length - Reusable Ventilator Tubing - polyester elastomer tube with silicone rubber cuffs BZO Set, Tubing And Support, Ventilator (W Harness) 1 KC 030-N - 10mm ID Reusable Ventilator Tubing
34 M996KC030BC0 KC 030-BC KC 030-BC, 22mm ID, 30" length - Reusable Ventilator Tubing - cream-colored pol KC 030-BC, 22mm ID, 30" length - Reusable Ventilator Tubing - cream-colored polyester elastomer tube with blue silicone rubber cuffs BZO Set, Tubing And Support, Ventilator (W Harness) 1 KC 030-BC - 22mm ID Reusable Ventilator Tubing
35 M996KC03019R0 KC 030-19R KC 030-19R, 19mm ID, 30" length - Reusable Ventilator Tubing - cream-colored po KC 030-19R, 19mm ID, 30" length - Reusable Ventilator Tubing - cream-colored polyester elastomer tube with red silicone rubber cuffs BZO Set, Tubing And Support, Ventilator (W Harness) 1 KC 030-19R - 19mm ID Reusable Ventilator Tubing
36 M996KC006GG0 KC 006-GG KC 006-GG, 22mm ID, 6" length - Reusable Ventilator Tubing - gray-colored polye KC 006-GG, 22mm ID, 6" length - Reusable Ventilator Tubing - gray-colored polyester elastomer tube with gray silicone rubber cuffs BZO Set, Tubing And Support, Ventilator (W Harness) 1 KC 006-GG - 22mm ID Reusable Ventilator Tubing
37 M996KC005N2P0 KC 00.5N-2P KC 00.5N-2P The KC 00.5N-2P is a 1/2-liter neoprene reservoir bag intended to store breathin The KC 00.5N-2P is a 1/2-liter neoprene reservoir bag intended to store breathing gas during the respiratory cycle. The breathing bag may be on the inspiratory or expiratory limb of a breathing circuit depending on the breathing circuit design. This is a single-use device. BTC Bag, Reservoir 1 KC 00.5N-2P 1/2-liter reservoir bag
38 M996KC004BC0 KC 004-BC KC 004-BC, 22mm ID, 4" length - Reusable Ventilator Tubing - cream-colored poly KC 004-BC, 22mm ID, 4" length - Reusable Ventilator Tubing - cream-colored polyester elastomer tube with blue silicone rubber cuffs BZO Set, Tubing And Support, Ventilator (W Harness) 1 KC 004-BC - 22mm ID Reusable Ventilator Tubing
39 M996KC002N2P0 KC 002N-2P KC 002N-2P The KC 002N-2P is a 2-liter neoprene reservoir bag intended to store breathing g The KC 002N-2P is a 2-liter neoprene reservoir bag intended to store breathing gas during the respiratory cycle. The breathing bag may be on the inspiratory or expiratory limb of a breathing circuit depending on the breathing circuit design. This is a single-use device. BTC Bag, Reservoir 1 KC 002N-2P 2-liter reservoir bag
40 M996BE183SUR0 BE 183-SUR BE 183-SUR The BE 183-SUR Manual Jet Ventilator is designed to provide trans-tracheal venti The BE 183-SUR Manual Jet Ventilator is designed to provide trans-tracheal ventilation in specific emergency situations of upper airway obstructions. This system is used in conjunction with a trans-tracheal catheter, or cricothyrotomy needle, which is inserted through the cricothyroid membrane. Ventilation is accomplished by the manual, intermittent jetting of oxygen through the catheter for subsequent lung inflation. BTL Ventilator, Emergency, Powered (Resuscitator) 2 Manual Jet Ventilator
41 M996BE183SUR120 BE 183-SUR-12 BE 183-SUR-12 The BE 183-SUR-12 Manual Jet Ventilator is designed to provide trans-tracheal ve The BE 183-SUR-12 Manual Jet Ventilator is designed to provide trans-tracheal ventilation in specific emergency situations of upper airway obstructions. This system is used in conjunction with a trans-tracheal catheter, or cricothyrotomy needle, which is inserted through the cricothyroid membrane. Ventilation is accomplished by the manual, intermittent jetting of oxygen through the catheter for subsequent lung inflation. BTL Ventilator, Emergency, Powered (Resuscitator) 2 Manual Jet Ventilator
42 M996BE148510 BE 148-5-1 BE 148-5-1 The BE 148-5-1 Gauge Clamp is an accessory to the NS Series Vacuum/Pressure Gaug The BE 148-5-1 Gauge Clamp is an accessory to the NS Series Vacuum/Pressure Gauges. The BE 148-5-1 securely mounts Gauges with a rear 1/4" NPT thread to 3/4" diameter poles. CAP Monitor, Airway Pressure (Includes Gauge And/Or Alarm) 2 BE 148-5-1 Gauge Clamp
43 M996BE183SU120 BE 183-SU-12 BE 183-SU-12 The BE 183-SU-12 Manual Jet Ventilator is designed to provide trans-tracheal ven The BE 183-SU-12 Manual Jet Ventilator is designed to provide trans-tracheal ventilation in specific emergency situations of upper airway obstructions. This system is used in conjunction with a trans-tracheal catheter, or cricothyrotomy needle, which is inserted through the cricothyroid membrane. Ventilation is accomplished by the manual, intermittent jetting of oxygen through the catheter for subsequent lung inflation. BTL Ventilator, Emergency, Powered (Resuscitator) 2 Manual Jet Ventilator
44 M996BE14910 BE 149-1 BE 149-1 The Instrumentation Industries, Inc. BE 149-1 Gauge Adapter has a 1/4" NPT conne The Instrumentation Industries, Inc. BE 149-1 Gauge Adapter has a 1/4" NPT connection on one end and a 15 mm I.D./22 mm O.D. connection on the other end for inspiratory monitoring.The BE 149-1 is designed to work with III Vacuum/Pressure Gauges and NIF Meters.The adapter is made of polycarbonate. BXR Meter, Airway Pressure (Inspiratory Force) 2 BE 149-1 Gauge Adapter
45 M996BE1250 BE 125 BE 125 The BE 125 Tee Adapter is intended for use in a ventilator, oxygen or BIPAP circ The BE 125 Tee Adapter is intended for use in a ventilator, oxygen or BIPAP circuit. Dimensions: 22mm O.D. x 15mm I.D./22mm O.D. x 15mm O.D./22mm O.D Reusable. CAI Circuit, Breathing (W Connector, Adaptor, Y Piece) 1 BE 125 ReusableTee Adapter
46 M996BE1145TB0 BE 114-5TB BE 114-5TB The BE114-5TB Flexible Support Arm Single Tubing Clamp holds a ventilator tube i The BE114-5TB Flexible Support Arm Single Tubing Clamp holds a ventilator tube in place when attached to an III "Flexible Support Arm". Made of polypropylene with phenolic ball knob mount. Made in the USA. JAY Support, Breathing Tube 1 BE114-5TB Flexible Support Arm Single Tubing Clamp
47 M996BE11420 BE 114-2 BE 114-2 The BE 114-2 Flexible Support Arm Pole Bracket permits mounting of "Flexible Sup The BE 114-2 Flexible Support Arm Pole Bracket permits mounting of "Flexible Support Arms" to poles up to 1.5" in diameter. Components and materials: bracket body: anodized aluminum; screw: steel with phenolic handle. Made in the USA. JAY Support, Breathing Tube 1 BE 114-2 Flexible Support Arm Pole Bracket
48 M996BE1060 BE 106 BE 106 Specialty Adapter with Vent - 15mm ID/22mm OD/15mm ID/22mm OD. Fits components o Specialty Adapter with Vent - 15mm ID/22mm OD/15mm ID/22mm OD. Fits components of adult ventilator circuits. Molded of polycarbonate. Reusable. BZA Connector, Airway (Extension) 1 BE 106 Adult Adapter with Vent
49 M996BE1052X22D0 BE 105-2X22D BE 105-2X22D General Adapter - 22mm ID x 22mm ID adapter for use in breathing/ventilator circ General Adapter - 22mm ID x 22mm ID adapter for use in breathing/ventilator circuit. Molded of polystyrene butadiene, Single Patient Use. CAI Circuit, Breathing (W Connector, Adaptor, Y Piece) BE 105-2X22D Adapter
50 M996BE1052X220 BE 105-2X22 BE 105-2X22 General Adapter - 22mm ID x 22mm ID adapter for use in breathing/ventilator circ General Adapter - 22mm ID x 22mm ID adapter for use in breathing/ventilator circuit. Molded of polycarbonate. Reusable. CAI Circuit, Breathing (W Connector, Adaptor, Y Piece) BE 105-2X22 Adapter
Other products with the same Product Code "BTL"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 35019517062209 124002 BCI SMITHS MEDICAL MD, INC.
2 35019517062179 124006 BCI SMITHS MEDICAL MD, INC.
3 35019517053849 125003 BCI SMITHS MEDICAL MD, INC.
4 35019315107478 530A1167 Pneupac SMITHS MEDICAL INTERNATIONAL LTD
5 35019315107270 P300NUS Pneupac SMITHS MEDICAL INTERNATIONAL LTD
6 35019315107263 P310NUS Pneupac SMITHS MEDICAL INTERNATIONAL LTD
7 35019315074862 VR1AIRNUS Pneupac SMITHS MEDICAL INTERNATIONAL LTD
8 35019315074183 V200DNUS Pneupac SMITHS MEDICAL INTERNATIONAL LTD
9 35019315072738 P200DNUS Pneupac SMITHS MEDICAL INTERNATIONAL LTD
10 35019315071892 B100NUS Pneupac SMITHS MEDICAL INTERNATIONAL LTD
11 M996BE183SUR120 BE 183-SUR-12 BE 183-SUR-12 The BE 183-SUR-12 Manual Jet Ventilator is designed to provide trans-tracheal ve The BE 183-SUR-12 Manual Jet Ventilator is designed to provide trans-tracheal ventilation in specific emergency situations of upper airway obstructions. This system is used in conjunction with a trans-tracheal catheter, or cricothyrotomy needle, which is inserted through the cricothyroid membrane. Ventilation is accomplished by the manual, intermittent jetting of oxygen through the catheter for subsequent lung inflation. Manual Jet Ventilator INSTRUMENTATION INDUSTRIES, INCORPORATED
12 M996BE183SUR0 BE 183-SUR BE 183-SUR The BE 183-SUR Manual Jet Ventilator is designed to provide trans-tracheal venti The BE 183-SUR Manual Jet Ventilator is designed to provide trans-tracheal ventilation in specific emergency situations of upper airway obstructions. This system is used in conjunction with a trans-tracheal catheter, or cricothyrotomy needle, which is inserted through the cricothyroid membrane. Ventilation is accomplished by the manual, intermittent jetting of oxygen through the catheter for subsequent lung inflation. Manual Jet Ventilator INSTRUMENTATION INDUSTRIES, INCORPORATED
13 M996BE183SU120 BE 183-SU-12 BE 183-SU-12 The BE 183-SU-12 Manual Jet Ventilator is designed to provide trans-tracheal ven The BE 183-SU-12 Manual Jet Ventilator is designed to provide trans-tracheal ventilation in specific emergency situations of upper airway obstructions. This system is used in conjunction with a trans-tracheal catheter, or cricothyrotomy needle, which is inserted through the cricothyroid membrane. Ventilation is accomplished by the manual, intermittent jetting of oxygen through the catheter for subsequent lung inflation. Manual Jet Ventilator INSTRUMENTATION INDUSTRIES, INCORPORATED
14 M996BE183SU0 BE 183-SU BE 183-SU The BE 183-SU Manual Jet Ventilator is designed to provide trans-tracheal ventil The BE 183-SU Manual Jet Ventilator is designed to provide trans-tracheal ventilation in specific emergency situations of upper airway obstructions. This system is used in conjunction with a trans-tracheal catheter, or cricothyrotomy needle, which is inserted through the cricothyroid membrane. Ventilation is accomplished by the manual, intermittent jetting of oxygen through the catheter for subsequent lung inflation. Manual Jet Ventilator INSTRUMENTATION INDUSTRIES, INCORPORATED
15 20637320035005 VM-3500 VM-3500 The VAR-Monitor is mounted onto the exhalation side of the VAR and has no direct The VAR-Monitor is mounted onto the exhalation side of the VAR and has no direct patient contact during its operation. If the VAR stops cycling, the VAR-Monitorâ„¢ detects the non-cycling condition and generates both an audible sound and a visible blinking (red color LED) light alerting the clinician who is attending the patient. VAR-Monitor VORTRAN MEDICAL TECHNOLOGY 1, INC
16 15019517189520 520A1126NESNONEU Pneupac SMITHS MEDICAL ASD, INC.
17 15019517189513 520A1125NONEU Pneupac SMITHS MEDICAL ASD, INC.
18 15019517181173 510A1960NONEU Pneupac SMITHS MEDICAL ASD, INC.
19 15019517180381 530A1167NFRNONEU Pneupac SMITHS MEDICAL ASD, INC.
20 15019517180374 530A1166NFRNONEU Pneupac SMITHS MEDICAL ASD, INC.
21 15019517180367 530A1166NONEU Pneupac SMITHS MEDICAL ASD, INC.
22 15019517178845 530A1167NONEU Pneupac SMITHS MEDICAL INTERNATIONAL LTD
23 15019517160222 100/905/341-CH Pneupac SMITHS MEDICAL INTERNATIONAL LTD
24 15019517160215 100/905/340-CH Pneupac SMITHS MEDICAL INTERNATIONAL LTD
25 15019517159660 100/905/320-CH Pneupac SMITHS MEDICAL INTERNATIONAL LTD
26 15019517159646 100/905/302-CH Pneupac SMITHS MEDICAL INTERNATIONAL LTD
27 15019517159608 100/905/301-CH Pneupac SMITHS MEDICAL INTERNATIONAL LTD
28 15019517159127 100/905/300-CH Pneupac SMITHS MEDICAL INTERNATIONAL LTD
29 15019315061080 100/905/302 Portex SMITHS MEDICAL INTERNATIONAL LTD
30 15019315061073 100/905/301 Portex SMITHS MEDICAL INTERNATIONAL LTD
31 15019315061066 100/905/300 Portex SMITHS MEDICAL INTERNATIONAL LTD
32 10807141000169 100627 MOVES Clamps MOVES THORNHILL RESEARCH INC
33 10807141000152 100626 MOVES Clamps MOVES THORNHILL RESEARCH INC
34 10807141000145 111422 Assy, Power Supply Charger Unit MOVES THORNHILL RESEARCH INC
35 10807141000138 100823 Assy, Battery Pack MOVES THORNHILL RESEARCH INC
36 10807141000121 124847 Assy, MOVES SLC, Accessory Case MOVES SLC THORNHILL RESEARCH INC
37 10807141000114 124846 ASSY, MOVES SLC System in Case MOVES SLC THORNHILL RESEARCH INC
38 10807141000084 124241 Hose, 0.04" x 0.0625", Nafion w/ Label MOVES THORNHILL RESEARCH INC
39 10807141000077 111560 ASSY, MOVES System Case MOVES THORNHILL RESEARCH INC
40 10807141000060 111559 ASSY, MOVES Accessory Case MOVES THORNHILL RESEARCH INC
41 10807141000046 101211 Assy, O2 Mask Breathing Circuit MOVES THORNHILL RESEARCH INC
42 10807141000022 101210 Assy, Ventilator Breathing Circuit MOVES THORNHILL RESEARCH INC
43 10807141000015 100696 Assy, O2 Mask Cartridge MOVES THORNHILL RESEARCH INC
44 10807141000008 100695 Assy, Ventilator Cartridge MOVES THORNHILL RESEARCH INC
45 10641043553282 10-55328 Neo-Tee Tubing Kit MERCURY ENTERPRISES, INC.
46 10641043515068 10-51506 Resusa-Tee T-Piece Resuscitator MERCURY ENTERPRISES, INC.
47 10641043515051 10-51505 Resusa-Tee T-Piece Resuscitator MERCURY ENTERPRISES, INC.
48 10641043515044 10-51504 Resusa-Tee T-Piece Resuscitator MERCURY ENTERPRISES, INC.
49 10641043515037 10-51503 Resusa-Tee T-Piece Resuscitator MERCURY ENTERPRISES, INC.
50 10641043515020 10-51502 Resusa-Tee T-Piece Resuscitator MERCURY ENTERPRISES, INC.