Other products from "HOBBS MEDICAL, INC."
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 M849G11200400 G1120040 4581-U An assembly of devices that uses radio-frequency (RF) alternating current to dev An assembly of devices that uses radio-frequency (RF) alternating current to develop heat directly within soft-tissue cells (thermodynamic) for cutting and coagulating tissue within a shield of argon (Ar) gas during surgery. It typically includes a generator, a single-use/reusable electrode handpiece with monopolar electrodes, connecting cables, foot-switch, and an argon gas supply system [housed in a separate trolley (cart) or incorporated into the system generator]. The current forms an ionized channel or arc within the argon shield which lessens the charring of tissue and provides rapid, uniform coagulation over large bleeding surfaces (e.g., capillary beds). KNS Unit, Electrosurgical, Endoscopic (With Or Without Accessories) 2 Hobbs Medical TouchSoft Coagulator
2 M84965850 6585 6585 A sterile non-bioabsorbable tubular device intended to be implanted in an obstru A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed pancreatic duct (e.g., due to stricture or malignancy) to maintain luminal patency; it may also be intended to treat a wide variety of conditions in pancreatic endoscopy (e.g., drain pseudocyst, treat fistula or duct disruption). It is made entirely of a synthetic polymer and has a continuous tube design with or without retention flanges. This is a single-use device. FGE Catheter, Biliary, Diagnostic 2 Freeman Pancreatic Flexi-Stent
3 M84965840 6584 6584 A sterile non-bioabsorbable tubular device intended to be implanted in an obstru A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed pancreatic duct (e.g., due to stricture or malignancy) to maintain luminal patency; it may also be intended to treat a wide variety of conditions in pancreatic endoscopy (e.g., drain pseudocyst, treat fistula or duct disruption). It is made entirely of a synthetic polymer and has a continuous tube design with or without retention flanges. This is a single-use device. FGE Catheter, Biliary, Diagnostic 2 Freeman Pancreatic Flexi-Stent
4 M84965820 6582 6582 A sterile non-bioabsorbable tubular device intended to be implanted in an obstru A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed pancreatic duct (e.g., due to stricture or malignancy) to maintain luminal patency; it may also be intended to treat a wide variety of conditions in pancreatic endoscopy (e.g., drain pseudocyst, treat fistula or duct disruption). It is made entirely of a synthetic polymer and has a continuous tube design with or without retention flanges. This is a single-use device. FGE Catheter, Biliary, Diagnostic 2 Freeman Pancreatic Flexi-Stent
5 M84965810 6581 6581 A sterile non-bioabsorbable tubular device intended to be implanted in an obstru A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed pancreatic duct (e.g., due to stricture or malignancy) to maintain luminal patency; it may also be intended to treat a wide variety of conditions in pancreatic endoscopy (e.g., drain pseudocyst, treat fistula or duct disruption). It is made entirely of a synthetic polymer and has a continuous tube design with or without retention flanges. This is a single-use device. FGE Catheter, Biliary, Diagnostic 2 Freeman Pancreatic Flexi-Stent
6 M84965760 6576 6576 A sterile non-bioabsorbable tubular device intended to be implanted in an obstru A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed pancreatic duct (e.g., due to stricture or malignancy) to maintain luminal patency; it may also be intended to treat a wide variety of conditions in pancreatic endoscopy (e.g., drain pseudocyst, treat fistula or duct disruption). It is made entirely of a synthetic polymer and has a continuous tube design with or without retention flanges. This is a single-use device. FGE Catheter, Biliary, Diagnostic 2 Freeman Pancreatic Flexi-Stent
7 M84965750 6575 6575 A sterile non-bioabsorbable tubular device intended to be implanted in an obstru A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed pancreatic duct (e.g., due to stricture or malignancy) to maintain luminal patency; it may also be intended to treat a wide variety of conditions in pancreatic endoscopy (e.g., drain pseudocyst, treat fistula or duct disruption). It is made entirely of a synthetic polymer and has a continuous tube design with or without retention flanges. This is a single-use device. FGE Catheter, Biliary, Diagnostic 2 Freeman Pancreatic Flexi-Stent
8 M84965740 6574 6574 A sterile non-bioabsorbable tubular device intended to be implanted in an obstru A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed pancreatic duct (e.g., due to stricture or malignancy) to maintain luminal patency; it may also be intended to treat a wide variety of conditions in pancreatic endoscopy (e.g., drain pseudocyst, treat fistula or duct disruption). It is made entirely of a synthetic polymer and has a continuous tube design with or without retention flanges. This is a single-use device. FGE Catheter, Biliary, Diagnostic 2 Freeman Pancreatic Flexi-Stent
9 M84965720 6572 6572 A sterile non-bioabsorbable tubular device intended to be implanted in an obstru A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed pancreatic duct (e.g., due to stricture or malignancy) to maintain luminal patency; it may also be intended to treat a wide variety of conditions in pancreatic endoscopy (e.g., drain pseudocyst, treat fistula or duct disruption). It is made entirely of a synthetic polymer and has a continuous tube design with or without retention flanges. This is a single-use device. FGE Catheter, Biliary, Diagnostic 2 Freeman Pancreatic Flexi-Stent
10 M84965710 6571 6571 A sterile non-bioabsorbable tubular device intended to be implanted in an obstru A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed pancreatic duct (e.g., due to stricture or malignancy) to maintain luminal patency; it may also be intended to treat a wide variety of conditions in pancreatic endoscopy (e.g., drain pseudocyst, treat fistula or duct disruption). It is made entirely of a synthetic polymer and has a continuous tube design with or without retention flanges. This is a single-use device. FGE Catheter, Biliary, Diagnostic 2 Freeman Pancreatic Flexi-Stent
11 M84965680 6568 6568 A sterile non-bioabsorbable tubular device intended to be implanted in an obstru A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed pancreatic duct (e.g., due to stricture or malignancy) to maintain luminal patency; it may also be intended to treat a wide variety of conditions in pancreatic endoscopy (e.g., drain pseudocyst, treat fistula or duct disruption). It is made entirely of a synthetic polymer and has a continuous tube design with or without retention flanges. This is a single-use device. FGE Catheter, Biliary, Diagnostic 2 Freeman Pancreatic Flexi-Stent
12 M84965670 6567 6567 A sterile non-bioabsorbable tubular device intended to be implanted in an obstru A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed pancreatic duct (e.g., due to stricture or malignancy) to maintain luminal patency; it may also be intended to treat a wide variety of conditions in pancreatic endoscopy (e.g., drain pseudocyst, treat fistula or duct disruption). It is made entirely of a synthetic polymer and has a continuous tube design with or without retention flanges. This is a single-use device. FGE Catheter, Biliary, Diagnostic 2 Freeman Pancreatic Flexi-Stent
13 M84965660 6566 6566 A sterile non-bioabsorbable tubular device intended to be implanted in an obstru A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed pancreatic duct (e.g., due to stricture or malignancy) to maintain luminal patency; it may also be intended to treat a wide variety of conditions in pancreatic endoscopy (e.g., drain pseudocyst, treat fistula or duct disruption). It is made entirely of a synthetic polymer and has a continuous tube design with or without retention flanges. This is a single-use device. FGE Catheter, Biliary, Diagnostic 2 Freeman Pancreatic Flexi-Stent
14 M84965650 6565 6565 A sterile non-bioabsorbable tubular device intended to be implanted in an obstru A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed pancreatic duct (e.g., due to stricture or malignancy) to maintain luminal patency; it may also be intended to treat a wide variety of conditions in pancreatic endoscopy (e.g., drain pseudocyst, treat fistula or duct disruption). It is made entirely of a synthetic polymer and has a continuous tube design with or without retention flanges. This is a single-use device. FGE Catheter, Biliary, Diagnostic 2 Freeman Pancreatic Flexi-Stent
15 M84965640 6564 6564 A sterile non-bioabsorbable tubular device intended to be implanted in an obstru A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed pancreatic duct (e.g., due to stricture or malignancy) to maintain luminal patency; it may also be intended to treat a wide variety of conditions in pancreatic endoscopy (e.g., drain pseudocyst, treat fistula or duct disruption). It is made entirely of a synthetic polymer and has a continuous tube design with or without retention flanges. This is a single-use device. FGE Catheter, Biliary, Diagnostic 2 Freeman Pancreatic Flexi-Stent
16 M84965620 6562 6562 A sterile non-bioabsorbable tubular device intended to be implanted in an obstru A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed pancreatic duct (e.g., due to stricture or malignancy) to maintain luminal patency; it may also be intended to treat a wide variety of conditions in pancreatic endoscopy (e.g., drain pseudocyst, treat fistula or duct disruption). It is made entirely of a synthetic polymer and has a continuous tube design with or without retention flanges. This is a single-use device. FGE Catheter, Biliary, Diagnostic 2 Freeman Pancreatic Flexi-Stent
17 M84965610 6561 6561 A sterile non-bioabsorbable tubular device intended to be implanted in an obstru A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed pancreatic duct (e.g., due to stricture or malignancy) to maintain luminal patency; it may also be intended to treat a wide variety of conditions in pancreatic endoscopy (e.g., drain pseudocyst, treat fistula or duct disruption). It is made entirely of a synthetic polymer and has a continuous tube design with or without retention flanges. This is a single-use device. FGE Catheter, Biliary, Diagnostic 2 Freeman Pancreatic Flexi-Stent
18 M84965550 6555 6555 A sterile non-bioabsorbable tubular device intended to be implanted in an obstru A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed pancreatic duct (e.g., due to stricture or malignancy) to maintain luminal patency; it may also be intended to treat a wide variety of conditions in pancreatic endoscopy (e.g., drain pseudocyst, treat fistula or duct disruption). It is made entirely of a synthetic polymer and has a continuous tube design with or without retention flanges. This is a single-use device. FGE Catheter, Biliary, Diagnostic 2 Freeman Pancreatic Flexi-Stent
19 M84965540 6554 6554 A sterile non-bioabsorbable tubular device intended to be implanted in an obstru A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed pancreatic duct (e.g., due to stricture or malignancy) to maintain luminal patency; it may also be intended to treat a wide variety of conditions in pancreatic endoscopy (e.g., drain pseudocyst, treat fistula or duct disruption). It is made entirely of a synthetic polymer and has a continuous tube design with or without retention flanges. This is a single-use device. FGE Catheter, Biliary, Diagnostic 2 Freeman Pancreatic Flexi-Stent
20 M84965520 6552 6552 A sterile non-bioabsorbable tubular device intended to be implanted in an obstru A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed pancreatic duct (e.g., due to stricture or malignancy) to maintain luminal patency; it may also be intended to treat a wide variety of conditions in pancreatic endoscopy (e.g., drain pseudocyst, treat fistula or duct disruption). It is made entirely of a synthetic polymer and has a continuous tube design with or without retention flanges. This is a single-use device. FGE Catheter, Biliary, Diagnostic 2 Freeman Pancreatic Flexi-Stent
21 M84965510 6551 6551 A sterile non-bioabsorbable tubular device intended to be implanted in an obstru A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed pancreatic duct (e.g., due to stricture or malignancy) to maintain luminal patency; it may also be intended to treat a wide variety of conditions in pancreatic endoscopy (e.g., drain pseudocyst, treat fistula or duct disruption). It is made entirely of a synthetic polymer and has a continuous tube design with or without retention flanges. This is a single-use device. FGE Catheter, Biliary, Diagnostic 2 Freeman Pancreatic Flexi-Stent
22 M84965480 6548 6548 A sterile non-bioabsorbable tubular device intended to be implanted in an obstru A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed pancreatic duct (e.g., due to stricture or malignancy) to maintain luminal patency; it may also be intended to treat a wide variety of conditions in pancreatic endoscopy (e.g., drain pseudocyst, treat fistula or duct disruption). It is made entirely of a synthetic polymer and has a continuous tube design with or without retention flanges. This is a single-use device. FGE Catheter, Biliary, Diagnostic 2 Freeman Pancreatic Flexi-Stent
23 M84965470 6547 6547 A sterile non-bioabsorbable tubular device intended to be implanted in an obstru A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed pancreatic duct (e.g., due to stricture or malignancy) to maintain luminal patency; it may also be intended to treat a wide variety of conditions in pancreatic endoscopy (e.g., drain pseudocyst, treat fistula or duct disruption). It is made entirely of a synthetic polymer and has a continuous tube design with or without retention flanges. This is a single-use device. FGE Catheter, Biliary, Diagnostic 2 Freeman Pancreatic Flexi-Stent
24 M84965460 6546 6546 A sterile non-bioabsorbable tubular device intended to be implanted in an obstru A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed pancreatic duct (e.g., due to stricture or malignancy) to maintain luminal patency; it may also be intended to treat a wide variety of conditions in pancreatic endoscopy (e.g., drain pseudocyst, treat fistula or duct disruption). It is made entirely of a synthetic polymer and has a continuous tube design with or without retention flanges. This is a single-use device. FGE Catheter, Biliary, Diagnostic 2 Freeman Pancreatic Flexi-Stent
25 M84965450 6545 6545 A sterile non-bioabsorbable tubular device intended to be implanted in an obstru A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed pancreatic duct (e.g., due to stricture or malignancy) to maintain luminal patency; it may also be intended to treat a wide variety of conditions in pancreatic endoscopy (e.g., drain pseudocyst, treat fistula or duct disruption). It is made entirely of a synthetic polymer and has a continuous tube design with or without retention flanges. This is a single-use device. FGE Catheter, Biliary, Diagnostic 2 Freeman Pancreatic Flexi-Stent
26 M84965440 6544 6544 A sterile non-bioabsorbable tubular device intended to be implanted in an obstru A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed pancreatic duct (e.g., due to stricture or malignancy) to maintain luminal patency; it may also be intended to treat a wide variety of conditions in pancreatic endoscopy (e.g., drain pseudocyst, treat fistula or duct disruption). It is made entirely of a synthetic polymer and has a continuous tube design with or without retention flanges. This is a single-use device. FGE Catheter, Biliary, Diagnostic 2 Freeman Pancreatic Flexi-Stent
27 M84965420 6542 6542 A sterile non-bioabsorbable tubular device intended to be implanted in an obstru A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed pancreatic duct (e.g., due to stricture or malignancy) to maintain luminal patency; it may also be intended to treat a wide variety of conditions in pancreatic endoscopy (e.g., drain pseudocyst, treat fistula or duct disruption). It is made entirely of a synthetic polymer and has a continuous tube design with or without retention flanges. This is a single-use device. FGE Catheter, Biliary, Diagnostic 2 Freeman Pancreatic Flexi-Stent
28 M84965410 6541 6541 A sterile non-bioabsorbable tubular device intended to be implanted in an obstru A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed pancreatic duct (e.g., due to stricture or malignancy) to maintain luminal patency; it may also be intended to treat a wide variety of conditions in pancreatic endoscopy (e.g., drain pseudocyst, treat fistula or duct disruption). It is made entirely of a synthetic polymer and has a continuous tube design with or without retention flanges. This is a single-use device. FGE Catheter, Biliary, Diagnostic 2 Freeman Pancreatic Flexi-Stent
29 M84965350 6535 6535 A sterile non-bioabsorbable tubular device intended to be implanted in an obstru A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed pancreatic duct (e.g., due to stricture or malignancy) to maintain luminal patency; it may also be intended to treat a wide variety of conditions in pancreatic endoscopy (e.g., drain pseudocyst, treat fistula or duct disruption). It is made entirely of a synthetic polymer and has a continuous tube design with or without retention flanges. This is a single-use device. FGE Catheter, Biliary, Diagnostic 2 Freeman Pancreatic Flexi-Stent
30 M84965340 6534 6534 A sterile non-bioabsorbable tubular device intended to be implanted in an obstru A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed pancreatic duct (e.g., due to stricture or malignancy) to maintain luminal patency; it may also be intended to treat a wide variety of conditions in pancreatic endoscopy (e.g., drain pseudocyst, treat fistula or duct disruption). It is made entirely of a synthetic polymer and has a continuous tube design with or without retention flanges. This is a single-use device. FGE Catheter, Biliary, Diagnostic 2 Freeman Pancreatic Flexi-Stent
31 M84965330 6533 6533 A sterile non-bioabsorbable tubular device intended to be implanted in an obstru A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed pancreatic duct (e.g., due to stricture or malignancy) to maintain luminal patency; it may also be intended to treat a wide variety of conditions in pancreatic endoscopy (e.g., drain pseudocyst, treat fistula or duct disruption). It is made entirely of a synthetic polymer and has a continuous tube design with or without retention flanges. This is a single-use device. FGE Catheter, Biliary, Diagnostic 2 Freeman Pancreatic Flexi-Stent
32 M84965320 6532 6532 A sterile non-bioabsorbable tubular device intended to be implanted in an obstru A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed pancreatic duct (e.g., due to stricture or malignancy) to maintain luminal patency; it may also be intended to treat a wide variety of conditions in pancreatic endoscopy (e.g., drain pseudocyst, treat fistula or duct disruption). It is made entirely of a synthetic polymer and has a continuous tube design with or without retention flanges. This is a single-use device. FGE Catheter, Biliary, Diagnostic 2 Freeman Pancreatic Flexi-Stent
33 M84963520 6352 6352 A sterile non-bioabsorbable tubular device intended to be implanted in an obstru A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed pancreatic duct (e.g., due to stricture or malignancy) to maintain luminal patency; it may also be intended to treat a wide variety of conditions in pancreatic endoscopy (e.g., drain pseudocyst, treat fistula or duct disruption). It is made entirely of a synthetic polymer and has a continuous tube design with or without retention flanges. This is a single-use device. FGE Catheter, Biliary, Diagnostic 2 Freeman Pancreatic Flexi-Stent
34 M84963510 6351 6351 A sterile non-bioabsorbable tubular device intended to be implanted in an obstru A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed pancreatic duct (e.g., due to stricture or malignancy) to maintain luminal patency; it may also be intended to treat a wide variety of conditions in pancreatic endoscopy (e.g., drain pseudocyst, treat fistula or duct disruption). It is made entirely of a synthetic polymer and has a continuous tube design with or without retention flanges. This is a single-use device. FGE Catheter, Biliary, Diagnostic 2 Freeman Pancreatic Flexi-Stent
35 M84963420 6342 6342 A sterile non-bioabsorbable tubular device intended to be implanted in an obstru A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed pancreatic duct (e.g., due to stricture or malignancy) to maintain luminal patency; it may also be intended to treat a wide variety of conditions in pancreatic endoscopy (e.g., drain pseudocyst, treat fistula or duct disruption). It is made entirely of a synthetic polymer and has a continuous tube design with or without retention flanges. This is a single-use device. FGE Catheter, Biliary, Diagnostic 2 Freeman Pancreatic Flexi-Stent
36 M84963410 6341 6341 A sterile non-bioabsorbable tubular device intended to be implanted in an obstru A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed pancreatic duct (e.g., due to stricture or malignancy) to maintain luminal patency; it may also be intended to treat a wide variety of conditions in pancreatic endoscopy (e.g., drain pseudocyst, treat fistula or duct disruption). It is made entirely of a synthetic polymer and has a continuous tube design with or without retention flanges. This is a single-use device. FGE Catheter, Biliary, Diagnostic 2 Freeman Pancreatic Flexi-Stent
37 M84961300 6130 6130 The Guiding Catheter is a sterile device inserted through a compatible flexible The Guiding Catheter is a sterile device inserted through a compatible flexible endoscope to aid in the initial placement of a stent, typically into a pancreatic or biliary duct in order to maintain patency. It is made of polytetrafluoroethylene (PTFE) with a radiopaque marker on the distal end. This is a single-use device. FGE Catheter, Biliary, Diagnostic 2 Hobbs Guiding Catheter
38 M84960150 6015 6015 Biliary Amsterdam Stent Kit includes Stent, Guide Wire, Push Catheter and Guide Catheter. FGE Catheter, Biliary, Diagnostic 2 Hobbs Biliary Amsterdam Stent Kit
39 M84960140 6014 6014 Biliary Amsterdam Stent Kit includes Stent, Guide Wire, Push Catheter and Guide Catheter. FGE Catheter, Biliary, Diagnostic 2 Hobbs Biliary Amsterdam Stent Kit
40 M84960130 6013 6013 Biliary Amsterdam Stent Kit includes Stent, Guide Wire, Push Catheter and Guide Catheter. FGE Catheter, Biliary, Diagnostic 2 Hobbs Biliary Amsterdam Stent Kit
41 M84960120 6012 6012 Biliary Amsterdam Stent Kit includes Stent, Guide Wire, Push Catheter and Guide Catheter. FGE Catheter, Biliary, Diagnostic 2 Hobbs Biliary Amsterdam Stent Kit
42 M84960110 6011 6011 Biliary Amsterdam Stent Kit includes Stent, Guide Wire, Push Catheter and Guide Catheter. FGE Catheter, Biliary, Diagnostic 2 Hobbs Biliary Amsterdam Stent Kit
43 M84960090 6009 6009 Biliary Amsterdam Stent Kit includes Stent, Guide Wire, Push Catheter and Guide Catheter. FGE Catheter, Biliary, Diagnostic 2 Hobbs Biliary Amsterdam Stent Kit
44 M84960060 6006 6006 Biliary Amsterdam Stent Kit includes Stent, Guide Wire, Push Catheter and Guide Catheter. FGE Catheter, Biliary, Diagnostic 2 Hobbs Biliary Amsterdam Stent Kit
45 M84960050 6005 6005 Biliary Amsterdam Stent Kit includes Stent, Guide Wire, Push Catheter and Guide Catheter. FGE Catheter, Biliary, Diagnostic 2 Hobbs Biliary Amsterdam Stent Kit
46 M84933060 3306 3306 A long flexible tube with an inflatable balloon at its distal tip used to dilate A long flexible tube with an inflatable balloon at its distal tip used to dilate gastrointestinal strictures of the lower esophageal schinctor. The balloon is inflated to its prescribed diameter to widen the affected passage of the tract. The device is multi-lumen and wire-guided. This is a single-use device. KNQ Dilator, Esophageal 2 Hobbs Achalasia Dilation Balloon
47 M84943520 4352 4352 The Hobbs Microbiology Brush is intended to be used in combination with a compat The Hobbs Microbiology Brush is intended to be used in combination with a compatible flexible endoscope to collect cells of the mucosa for pathological diagnosis during endoscopy. It is inserted through the working channel of the endoscope and consists of a flexible insertion portion made of a metal coil inside a plastic tube, whose distal end is equipped with plastic bristles for harvesting and protecting mucosal cells, e.g., during endoscopy. This is a single-use device. FDX Endoscopic Cytology Brush 2 Hobbs Microbiology Brush
48 M84943200 4320 4320 The Hobbs Microbiology Brush is intended to be used in combination with a compat The Hobbs Microbiology Brush is intended to be used in combination with a compatible flexible endoscope to collect cells of the mucosa for pathological diagnosis during endoscopy. It is inserted through the working channel of the endoscope and consists of a flexible insertion portion made of a metal coil inside a plastic tube, whose distal end is equipped with plastic bristles for harvesting and protecting mucosal cells, e.g., during endoscopy. This is a single-use device. FDX Endoscopic Cytology Brush 2 Hobbs Microbiology Brush
49 M84943100 4310 4310 The Hobbs Microbiology Brush is intended to be used in combination with a compat The Hobbs Microbiology Brush is intended to be used in combination with a compatible flexible endoscope to collect cells of the mucosa for pathological diagnosis during endoscopy. It is inserted through the working channel of the endoscope and consists of a flexible insertion portion made of a metal coil inside a plastic tube, whose distal end is equipped with plastic bristles for harvesting and protecting mucosal cells, e.g., during endoscopy. This is a single-use device. FDX Endoscopic Cytology Brush Hobbs Microbiology Brush
50 M84933040 3304 3304 A long flexible tube with an inflatable balloon at its distal tip used to dilate A long flexible tube with an inflatable balloon at its distal tip used to dilate gastrointestinal strictures of the lower esophageal schinctor. The balloon is inflated to its prescribed diameter to widen the affected passage of the tract. The device is multi-lumen and wire-guided. This is a single-use device. KNQ Dilator, Esophageal 2 Hobbs Achalasia Dilation Balloon
Other products with the same Product Code "FAD"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 05708932703932 BCHT77 BCHT77 ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 07 leng ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 07 length 22 cm with steerable pusher CH FR 06 and Orchestra™ guidewire and Flush ureteric catheter CH FR 06 Porges Coloplast COLOPLAST A/S
2 05708932703901 BCHT72 BCHT72 ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 07 leng ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 07 length 20 cm with steerable pusher CH FR 06 and Orchestra™ guidewire and Flush ureteric catheter CH FR 06 Porges Coloplast COLOPLAST A/S
3 05708932703871 BCHT71 BCHT71 ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 07 leng ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 07 length 16 cm with steerable pusher CH FR 06 and Orchestra™ guidewire and Flush ureteric catheter CH FR 06 Porges Coloplast COLOPLAST A/S
4 05708932703840 BCHT66 BCHT66 ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 06 leng ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 06 length 30 cm with steerable pusher CH FR 06 and Orchestra™ guidewire and Flush ureteric catheter CH FR 06 Porges Coloplast COLOPLAST A/S
5 05708932703819 BCHT65 BCHT65 ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 06 leng ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 06 length 28 cm with steerable pusher CH FR 06 and Orchestra™ guidewire and Flush ureteric catheter CH FR 06 Porges Coloplast COLOPLAST A/S
6 05708932703789 BCHT64 BCHT64 ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 06 leng ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 06 length 26 cm with steerable pusher CH FR 06 and Orchestra™ guidewire and Flush ureteric catheter CH FR 06 Porges Coloplast COLOPLAST A/S
7 05708932703734 BCHT63 BCHT63 ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 06 leng ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 06 length 24 cm with steerable pusher CH FR 06 and Orchestra™ guidewire and Flush ureteric catheter CH FR 06 Porges Coloplast COLOPLAST A/S
8 05708932703703 BCHT67 BCHT67 ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 06 leng ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 06 length 22 cm with steerable pusher CH FR 06 and Orchestra™ guidewire and Flush ureteric catheter CH FR 06 Porges Coloplast COLOPLAST A/S
9 05708932703673 BCHT62 BCHT62 ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 06 leng ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 06 length 20 cm with steerable pusher CH FR 06 and Orchestra™ guidewire and Flush ureteric catheter CH FR 06 Porges Coloplast COLOPLAST A/S
10 05708932703642 BCHT61 BCHT61 ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 06 leng ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 06 length 16 cm with steerable pusher CH FR 06 and Orchestra™ guidewire and Flush ureteric catheter CH FR 06 Porges Coloplast COLOPLAST A/S
11 05708932703611 BCHS86 BCHS86 ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 08 leng ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 08 length 30cm with steerable pusher CH FR 08 and Orchestra™ guidewire Porges Coloplast COLOPLAST A/S
12 05708932703581 BCHS85 BCHS85 ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 08 leng ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 08 length 28 cm with steerable pusher CH FR 08 and Orchestra™ guidewire Porges Coloplast COLOPLAST A/S
13 05708932703550 BCHS84 BCHS84 ImaJin™ Silicone hydro-coatedDouble loop ureteral stent open/open CH FR 08 lengt ImaJin™ Silicone hydro-coatedDouble loop ureteral stent open/open CH FR 08 length 26 cm with steerable pusher CH FR 08 and Orchestra™ guidewire Porges Coloplast COLOPLAST A/S
14 05708932703529 BCHS83 BCHS83 ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 08 leng ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 08 length 24 cm with steerable pusher CH FR 08 and Orchestra™ guidewire Porges Coloplast COLOPLAST A/S
15 05708932703499 BCHS82 BCHS82 ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 08 leng ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 08 length 20 cm with steerable pusher CH FR 08 and Orchestra™ guidewire Porges Coloplast COLOPLAST A/S
16 05708932703468 BCHS81 BCHS81 ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 08 leng ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 08 length 16 cm with steerable pusher CH FR 08 and Orchestra™ guidewire Porges Coloplast COLOPLAST A/S
17 05708932703437 BCHS76 BCHS76 ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 07 leng ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 07 length 30 cm with steerable pusher CH FR 06 and Orchestra™ guidewire Porges Coloplast COLOPLAST A/S
18 05708932703406 BCHS75 BCHS75 ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 07 leng ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 07 length 28 cm with steerable pusher CH FR 06 and Orchestra™ guidewire Porges Coloplast COLOPLAST A/S
19 05708932703376 BCHS74 BCHS74 ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 07 leng ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 07 length 26 cm with steerable pusher CH FR 06 and Orchestra™ guidewire Porges Coloplast COLOPLAST A/S
20 05708932703345 BCHS73 BCHS73 ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 07 leng ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 07 length 24 cm with steerable pusher CH FR 06 and Orchestra™ guidewire Porges Coloplast COLOPLAST A/S
21 05708932703314 BCHS77 BCHS77 ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 07 leng ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 07 length 22 cm with steerable pusher CH FR 06 and Orchestra™ guidewire Porges Coloplast COLOPLAST A/S
22 05708932703284 BCHS72 BCHS72 ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 07 leng ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 07 length 20 cm with steerable pusher CH FR 06 and Orchestra™ guidewire Porges Coloplast COLOPLAST A/S
23 05708932703253 BCHS71 BCHS71 ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 07 leng ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 07 length 16 cm with steerable pusher CH FR 06 and Orchestra™ guidewire Porges Coloplast COLOPLAST A/S
24 05708932703222 BCHS66 BCHS66 ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 06 leng ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 06 length 30 cm with steerable pusher CH FR 06 and Orchestra™ guidewire Porges Coloplast COLOPLAST A/S
25 05708932703192 BCHS65 BCHS65 ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 06 leng ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 06 length 28 cm with steerable pusher CH FR 06 and Orchestra™ guidewire Porges Coloplast COLOPLAST A/S
26 05708932703161 BCHS64 BCHS64 ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 06 leng ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 06 length 26 cm with steerable pusher CH FR 06 and Orchestra™ guidewire Porges Coloplast COLOPLAST A/S
27 05708932703130 BCHS63 BCHS63 ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 06 leng ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 06 length 24 cm with steerable pusher CH FR 06 and Orchestra™ guidewire Porges Coloplast COLOPLAST A/S
28 05708932703109 BCHS67 BCHS67 ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 06 leng ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 06 length 22 cm with steerable pusher CH FR 06 and Orchestra™ guidewire Porges Coloplast COLOPLAST A/S
29 05708932703079 BCHS62 BCHS62 ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 06 leng ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 06 length 20 cm with steerable pusher CH FR 06 and Orchestra™ guidewire Porges Coloplast COLOPLAST A/S
30 05708932703048 BCHS61 BCHS61 ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 06 leng ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 06 length 16 cm with steerable pusher CH FR 06 and Orchestra™ guidewire Porges Coloplast COLOPLAST A/S
31 05708932064323 BCFT67 BCFT67 VORTEK® Double loop ureteral stent with hydrogel coating open/open CH FR 06 leng VORTEK® Double loop ureteral stent with hydrogel coating open/open CH FR 06 length 22 cm with steerable pusher CH FR 06 and Orchestra™ guidewire and Flush ureteric catheter CH FR 06 Porges Coloplast COLOPLAST A/S
32 05708932064293 BCFT66 BCFT66 VORTEK® Double loop ureteral stent with hydrogel coating open/open CH FR 06 leng VORTEK® Double loop ureteral stent with hydrogel coating open/open CH FR 06 length 30 cm with steerable pusher CH FR 06 and Orchestra™ guidewire and Flush ureteric catheter CH FR 06 Porges Coloplast COLOPLAST A/S
33 05708932064262 BCFT65 BCFT65 VORTEK® Double loop ureteral stent with hydrogel coating open/open CH FR 06 leng VORTEK® Double loop ureteral stent with hydrogel coating open/open CH FR 06 length 28 cm with steerable pusher CH FR 06 and Orchestra™ guidewire and Flush ureteric catheter CH FR 06 Porges Coloplast COLOPLAST A/S
34 05708932064231 BCFT64 BCFT64 VORTEK® Double loop ureteral stent with hydrogel coating open/open CH FR 06 leng VORTEK® Double loop ureteral stent with hydrogel coating open/open CH FR 06 length 26 cm with steerable pusher CH FR 06 and Orchestra™ guidewire and Flush ureteric catheter CH FR 06 Porges Coloplast COLOPLAST A/S
35 05708932064200 BCFT63 BCFT63 VORTEK® Double loop ureteral stent with hydrogel coating open/open CH FR 06 leng VORTEK® Double loop ureteral stent with hydrogel coating open/open CH FR 06 length 24 cm with steerable pusher CH FR 06 and Orchestra™ guidewire and Flush ureteric catheter CH FR 06 Porges Coloplast COLOPLAST A/S
36 05708932064170 BCFT57 BCFT57 VORTEK® Double loop ureteral stent with hydrogel coating open/open CH FR 4.8 len VORTEK® Double loop ureteral stent with hydrogel coating open/open CH FR 4.8 length 22 cm with non steerable pusher CH FR 4.8 and Orchestra™ guidewire and Flush ureteric catheter CH FR 06 Porges Coloplast COLOPLAST A/S
37 05708932704021 BCHT75 BCHT75 ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 07 leng ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 07 length 28 cm with steerable pusher CH FR 06 and Orchestra™ guidewire and Flush ureteric catheter CH FR 06 Porges Coloplast COLOPLAST A/S
38 05708932703994 BCHT74 BCHT74 ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 07 leng ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 07 length 26 cm with steerable pusher CH FR 06 and Orchestra™ guidewire and Flush ureteric catheter CH FR 06 Porges Coloplast COLOPLAST A/S
39 05708932703963 BCHT73 BCHT73 ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 07 leng ImaJin™ Silicone hydro-coated Double loop ureteral stent open/open CH FR 07 length 24 cm with steerable pusher CH FR 06 and Orchestra™ guidewire and Flush ureteric catheter CH FR 06 Porges Coloplast COLOPLAST A/S
40 05708932705424 BCHJ86 BCHJ86 ImaJin™ Double loop ureteral stent silicone hydro-coated open/open CH FR 08 leng ImaJin™ Double loop ureteral stent silicone hydro-coated open/open CH FR 08 length 30 cm with steerable pusher Porges Coloplast COLOPLAST A/S
41 05708932705394 BCHJ85 BCHJ85 ImaJin™ Double loop ureteral stent silicone hydro-coated open/open CH FR 08 leng ImaJin™ Double loop ureteral stent silicone hydro-coated open/open CH FR 08 length 28 cm with steerable pusher Porges Coloplast COLOPLAST A/S
42 05708932705363 BCHJ84 BCHJ84 ImaJin™ Double loop ureteral stent silicone hydro-coated open/open CH FR 08 leng ImaJin™ Double loop ureteral stent silicone hydro-coated open/open CH FR 08 length 26 cm with steerable pusher Porges Coloplast COLOPLAST A/S
43 05708932705332 BCHJ83 BCHJ83 ImaJin™ Double loop ureteral stent silicone hydro-coated open/open CH FR 08 leng ImaJin™ Double loop ureteral stent silicone hydro-coated open/open CH FR 08 length 24 cm with steerable pusher Porges Coloplast COLOPLAST A/S
44 05708932705301 BCHJ82 BCHJ82 ImaJin™ Double loop ureteral stent silicone hydro-coated open/open CH FR 08 leng ImaJin™ Double loop ureteral stent silicone hydro-coated open/open CH FR 08 length 20 cm with steerable pusher Porges Coloplast COLOPLAST A/S
45 05708932705271 BCHJ81 BCHJ81 ImaJin™ Double loop ureteral stent silicone hydro-coated open/open CH FR 08 leng ImaJin™ Double loop ureteral stent silicone hydro-coated open/open CH FR 08 length 16 cm with steerable pusher Porges Coloplast COLOPLAST A/S
46 05708932705240 BCHJ76 BCHJ76 ImaJin™ Double loop ureteral stent silicone hydro-coated open/open CH FR 07 leng ImaJin™ Double loop ureteral stent silicone hydro-coated open/open CH FR 07 length 30 cm with steerable pusher Porges Coloplast COLOPLAST A/S
47 05708932705219 BCHJ75 BCHJ75 ImaJin™ Double loop ureteral stent silicone hydro-coated open/open CH FR 07 leng ImaJin™ Double loop ureteral stent silicone hydro-coated open/open CH FR 07 length 28 cm with steerable pusher Porges Coloplast COLOPLAST A/S
48 05708932705189 BCHJ74 BCHJ74 ImaJin™ Double loop ureteral stent silicone hydro-coated open/open CH FR 07 leng ImaJin™ Double loop ureteral stent silicone hydro-coated open/open CH FR 07 length 26 cm with steerable pusher Porges Coloplast COLOPLAST A/S
49 05708932705158 BCHJ73 BCHJ73 ImaJin™ Double loop ureteral stent silicone hydro-coated open/open CH FR 07 leng ImaJin™ Double loop ureteral stent silicone hydro-coated open/open CH FR 07 length 24 cm with steerable pusher Porges Coloplast COLOPLAST A/S
50 05708932705127 BCHJ77 BCHJ77 ImaJin™ Double loop ureteral stent silicone hydro-coated open/open CH FR 07 leng ImaJin™ Double loop ureteral stent silicone hydro-coated open/open CH FR 07 length 22 cm with steerable pusher Porges Coloplast COLOPLAST A/S