Other products from "THERMOPEUTIX, INC."
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 M781S1835401501 S18/35-40-150 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
2 M781S1835201501 S18/35-20-150 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
3 M781S1435401501 S14/35-40-150 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
4 M781S1418601501 S14/18-60-150 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
5 M781P141201501 P14-120-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
6 M781S1435201501 S14/35-20-150 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
7 M781S1418401501 S14/18-40-150 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
8 M781S1418201701 S14/18-20-170 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
9 M781S1418201501 S14/18-20-150 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
10 M781P35401501 P35-40-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
11 M781P35201501 P35-20-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
12 M781P351201701 P35-120-170 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
13 M781P351201501 P35-120-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
14 M781P18601501 P18-60-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
15 M781P18401501 P18-40-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
16 M781P18201501 P18-20-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
17 M781P181201501 P18-120-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
18 M781P1460150HF1 P14-60-150HF The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
19 M781P1440150HF1 P14-40-150HF The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
20 M781P14401501 P14-40-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
21 M781P1420150HF1 P14-20-150HF The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
22 M781P14120150HF1 P14-120-150HF The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
23 M781DFH80115901 DFH80-115/90 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
24 M781DFH80115801 DFH80-115/80 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
25 M781DFH60115901 DFH60-115/90 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
26 M781DFH60115801 DFH60-115/80 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
27 M781DFH10135901 DFH10-135/90 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
28 M781DFH10115901 DFH10-115/90 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
29 M781DFH10115801 DFH10-115/80 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
30 M781DF10115801 DF10-115/80 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
31 M7819680801 96-8080 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
32 M7819660601 96-6060 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
33 M7819645251 96-4525 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
34 M7819610101 96-1010 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
35 M7819445451 94-4545 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
36 M7819280801 92-8080 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
37 M7819260601 92-6060 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
38 M7819260251 92-6025 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
39 M7819245451 92-4545 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
40 M7819245251 92-4525 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
41 M7819210101 92-1010 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
42 M7819180801 91-8080 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
43 M7819180601 91-8060 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
44 M7819180451 91-8045 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
45 M7819180251 91-8025 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
46 M7819160601 91-6060 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
47 M7819160451 91-6045 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
48 M7819160251 91-6025 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
49 M7819145451 91-4545 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
50 M7819145251 91-4525 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlu The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
Other products with the same Product Code "DQY"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 04987892077319 NC18151 PN*NA18153H NAVICROSS Support Catheter NAVICROSS TERUMO CORPORATION
2 04987892077296 NC18150 PN*NS18153H NAVICROSS Support Catheter NAVICROSS TERUMO CORPORATION
3 04987892077272 NC18131 PN*NA180N3H NAVICROSS Support Catheter NAVICROSS TERUMO CORPORATION
4 04987892077258 NC18130 PN*NS180N3H NAVICROSS Support Catheter NAVICROSS TERUMO CORPORATION
5 04987892077234 NC18901 PN*NA18093H NAVICROSS Support Catheter NAVICROSS TERUMO CORPORATION
6 04987892077210 NC18900 PN*NS18093H NAVICROSS Support Catheter NAVICROSS TERUMO CORPORATION
7 04987892077197 NC18651 PN*NA180G3H NAVICROSS Support Catheter NAVICROSS TERUMO CORPORATION
8 04987892077173 NC18650 PN*NS180G3H NAVICROSS Support Catheter NAVICROSS TERUMO CORPORATION
9 04987892058875 M3-1430 NC*A853B FineCross M3 Coronary Micro-Guide Catheter FINECROSS TERUMO CORPORATION
10 04987892058851 M3-1450 NC*A855B FineCross M3 Coronary Micro-Guide Catheter FINECROSS TERUMO CORPORATION
11 04987892046636 WG-S7ST1L23A WG-S7ST1L23A R2P SlenGuide Guiding Catheter R2P SLENGUIDE TERUMO CORPORATION
12 04987892046575 WG-S7ST1L53A WG-S7ST1L53A R2P SlenGuide Guiding Catheter R2P SLENGUIDE TERUMO CORPORATION
13 04987350709301 NC35150 WS*NS35153H NAVICROSS Support Catheter NAVICROSS TERUMO CORPORATION
14 04987350709288 NC35130 WS*NS350N3H NAVICROSS Support Catheter NAVICROSS TERUMO CORPORATION
15 04987350709264 NC35900 WS*NS35093H NAVICROSS Support Catheter NAVICROSS TERUMO CORPORATION
16 04987350709240 NC35650 WS*NS350G3H NAVICROSS Support Catheter NAVICROSS TERUMO CORPORATION
17 04987350709226 NC35151 WS*NA35153H NAVICROSS Support Catheter NAVICROSS TERUMO CORPORATION
18 04987350709202 NC35131 WS*NA350N3H NAVICROSS Support Catheter NAVICROSS TERUMO CORPORATION
19 04987350709189 NC35901 WS*NA35093H NAVICROSS Support Catheter NAVICROSS TERUMO CORPORATION
20 04987350709165 NC35651 WS*NA350G3H NAVICROSS Support Catheter NAVICROSS TERUMO CORPORATION
21 04987350609199 MC272156S-J MC272156S Microcatheter Headway MICROVENTION INC.
22 04960685205427 OPC-0708135 PRESSANA TORAY INDUSTRIES,INC.
23 04960685205038 OPC-0315135 PRESSANA TORAY INDUSTRIES,INC.
24 04960685205021 OPC-0308135 PRESSANA TORAY INDUSTRIES,INC.
25 04547327142793 FBKX-8A110DY FUBUKI XF ASAHI INTECC CO., LTD.
26 04547327142786 FBKX-8S110DY FUBUKI XF ASAHI INTECC CO., LTD.
27 04547327142779 FBKX-8A100DY FUBUKI XF ASAHI INTECC CO., LTD.
28 04547327142762 FBKX-8S100DY FUBUKI XF ASAHI INTECC CO., LTD.
29 04547327142755 FBKX-8A90DY FUBUKI XF ASAHI INTECC CO., LTD.
30 04547327142748 FBKX-8S90DY FUBUKI XF ASAHI INTECC CO., LTD.
31 04547327142731 FBKX-8A80DY FUBUKI XF ASAHI INTECC CO., LTD.
32 04547327142724 FBKX-8S80DY FUBUKI XF ASAHI INTECC CO., LTD.
33 04547327134040 CSAR135-18N ASAHI Corsair Armet 18 ASAHI INTECC CO., LTD.
34 04547327134033 CSAR110-18N ASAHI Corsair Armet 18 ASAHI INTECC CO., LTD.
35 04547327134026 CSAR090-18N ASAHI Corsair Armet 18 ASAHI INTECC CO., LTD.
36 04547327134019 CSAR060-18N ASAHI Corsair Armet 18 ASAHI INTECC CO., LTD.
37 04547327133937 PSC35170C CROSSWALK ASAHI INTECC CO., LTD.
38 04547327133920 PSC35150C CROSSWALK ASAHI INTECC CO., LTD.
39 04547327133913 PSC35135C CROSSWALK ASAHI INTECC CO., LTD.
40 04547327133906 PSC35110C CROSSWALK ASAHI INTECC CO., LTD.
41 04547327133890 PSC35090C CROSSWALK ASAHI INTECC CO., LTD.
42 04547327133883 PSC35170B CROSSWALK ASAHI INTECC CO., LTD.
43 04547327133876 PSC35150B CROSSWALK ASAHI INTECC CO., LTD.
44 04547327133869 PSC35135B CROSSWALK ASAHI INTECC CO., LTD.
45 04547327133852 PSC35110B CROSSWALK ASAHI INTECC CO., LTD.
46 04547327133845 PSC35090B CROSSWALK ASAHI INTECC CO., LTD.
47 04547327133838 PSC18170C CROSSWALK ASAHI INTECC CO., LTD.
48 04547327133821 PSC18150C CROSSWALK ASAHI INTECC CO., LTD.
49 04547327133814 PSC18135C CROSSWALK ASAHI INTECC CO., LTD.
50 04547327133807 PSC18110C CROSSWALK ASAHI INTECC CO., LTD.