Other products from "THERMOPEUTIX, INC."
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 M781S1835401501 S18/35-40-150 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
2 M781S1835201501 S18/35-20-150 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
3 M781S1435401501 S14/35-40-150 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
4 M781S1418601501 S14/18-60-150 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
5 M781P141201501 P14-120-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
6 M781S1435201501 S14/35-20-150 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
7 M781S1418401501 S14/18-40-150 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
8 M781S1418201701 S14/18-20-170 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
9 M781S1418201501 S14/18-20-150 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
10 M781P35601501 P35-60-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
11 M781P35401501 P35-40-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
12 M781P35201501 P35-20-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
13 M781P351201701 P35-120-170 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
14 M781P351201501 P35-120-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
15 M781P18401501 P18-40-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
16 M781P18201501 P18-20-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
17 M781P181201501 P18-120-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
18 M781P1460150HF1 P14-60-150HF The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
19 M781P1440150HF1 P14-40-150HF The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
20 M781P14401501 P14-40-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
21 M781P1420150HF1 P14-20-150HF The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
22 M781P14120150HF1 P14-120-150HF The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
23 M781DFH80115901 DFH80-115/90 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
24 M781DFH80115801 DFH80-115/80 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
25 M781DFH60115901 DFH60-115/90 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
26 M781DFH60115801 DFH60-115/80 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
27 M781DFH10135901 DFH10-135/90 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
28 M781DFH10115901 DFH10-115/90 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
29 M781DFH10115801 DFH10-115/80 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
30 M781DF10115801 DF10-115/80 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
31 M7819680801 96-8080 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
32 M7819660601 96-6060 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
33 M7819645251 96-4525 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
34 M7819610101 96-1010 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
35 M7819445451 94-4545 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
36 M7819280801 92-8080 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
37 M7819260601 92-6060 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
38 M7819260251 92-6025 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
39 M7819245451 92-4545 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
40 M7819245251 92-4525 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
41 M7819210101 92-1010 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
42 M7819180801 91-8080 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
43 M7819180601 91-8060 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
44 M7819180451 91-8045 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
45 M7819180251 91-8025 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
46 M7819160601 91-6060 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
47 M7819160451 91-6045 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
48 M7819160251 91-6025 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
49 M7819145451 91-4545 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
50 M7819145251 91-4525 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlu The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
Other products with the same Product Code "DQY"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 10885074284153 LA8MB1SHD CATHETER LA8MB1SHD 8F 90CM MB1 Launcher MEDTRONIC, INC.
2 10885074064151 LA6MRESS CATHETER LA6MRESS LA 6F 100CM MRESS Launcher MEDTRONIC, INC.
3 10885074064144 LA5MRESS CATHETER LA5MRESS LA 5F 100CM MRESS Launcher MEDTRONIC, INC.
4 10885074064090 LA6RRAD CATHETER LA6RRAD LA 6F 100CM RRAD Launcher MEDTRONIC, INC.
5 10885074064083 LA5RRAD CATHETER LA5RRAD LA 5F 100CM RRAD Launcher MEDTRONIC, INC.
6 10885074050123 LA8JR40K CATHETER LA8JR40K LA 8F 55CM JR40 Launcher MEDTRONIC, INC.
7 10885074050109 LA7JR40K CATHETER LA7JR40K LA 7F 55CM JR40 Launcher MEDTRONIC, INC.
8 10878528000959 RC056125 RC056125 REVIVE 056 intermediate catheter 131cm 5.0F (0.66 Inch/1.68mm) I.D. 0.056 Inch ( REVIVE 056 intermediate catheter 131cm 5.0F (0.66 Inch/1.68mm) I.D. 0.056 Inch (1.42mm) 125cm Contents: 1 Intermediate Catheter Minimum Guiding Catheter I.D. in./(mm) 0.070 Inch/1.78mm) REVIVE MEDOS INTERNATIONAL SÀRL
9 10878528000942 RC056115 RC056115 REVIVE 056 intermediate catheter 121cm 5.0F (.066 Inch/1.68mm) I.D. 0.056 Inch ( REVIVE 056 intermediate catheter 121cm 5.0F (.066 Inch/1.68mm) I.D. 0.056 Inch (1.42mm) 115 cm Contents: 1 Intermediate Catheter Minimum Guiding Catheter I.D. in./(mm) 0.070 Inch/(1.78mm) REVIVE MEDOS INTERNATIONAL SÀRL
10 10878528000911 RC044130 RC044130 REVIVE 044 intermediate catheter 136cm 4.1F (.054 Inch/1.37mm) I.D. 0.044 Inch ( REVIVE 044 intermediate catheter 136cm 4.1F (.054 Inch/1.37mm) I.D. 0.044 Inch (1.12mm) 130cm Contents: 1 Intermediate Catheter Minimum Guiding Catheter I.D. in./(mm) 0.060 Inch/(1.52mm) REVIVE MEDOS INTERNATIONAL SÀRL
11 10878528000898 RC044115 RC044115 REVIVE 044 intermediate catheter 121cm 4.1F (.054 Inch/1.37mm) I.D. 0.044 Inch ( REVIVE 044 intermediate catheter 121cm 4.1F (.054 Inch/1.37mm) I.D. 0.044 Inch (1.12mm) 115cm Contents: 1 Intermediate Catheter Minimum Guiding Catheter I.D. in./(mm) 0.060 Inch/(1.52mm) REVIVE MEDOS INTERNATIONAL SÀRL
12 10878528000676 671-258-05D 67125805D ENVOY DA Guiding Catheter MPD 105cm 6F (2.0mm) 0.071 Inches (1.8mm) ENVOY MEDOS INTERNATIONAL SÀRL
13 10878528000669 671-260-05D 67126005D ENVOY DA Guiding Catheter STR 105cm 6F (2.0mm) 0.071 Inches (1.8mm) ENVOY MEDOS INTERNATIONAL SÀRL
14 10878528000652 671-258-95D 67125895D ENVOY DA Guiding Catheter MPD 95cm 6F (2.0mm) 0.071 Inches (1.8mm) ENVOY MEDOS INTERNATIONAL SÀRL
15 10878528000645 671-260-95D 67126095D ENVOY DA Guiding Catheter STR 95cm 6F (2.0mm) 0.071 Inches (1.8mm) ENVOY MEDOS INTERNATIONAL SÀRL
16 10852528005695 035-XC-200-1 7-10043-02 200 cm, 0.035" guidewire compatible, support catheter ViperCath XC CARDIOVASCULAR SYSTEMS, INC.
17 10852528005688 035-XC-200-0 7-10043-01 200 cm, 0.035" guidewire compatible, support catheter ViperCath XC CARDIOVASCULAR SYSTEMS, INC.
18 10850026568254 P1VC-035ANG-150 7-10094-08 ViperCross Support Catheter, 035", 150cm, Angled ViperCross CARDIOVASCULAR SYSTEMS, INC.
19 10850026568247 P1VC-035ANG-135 7-10094-07 ViperCross Support Catheter, 035", 135cm, Angled ViperCross CARDIOVASCULAR SYSTEMS, INC.
20 10850026568230 P1VC-035ANG-090 7-10094-06 ViperCross Support Catheter, 035", 90cm, Angled ViperCross CARDIOVASCULAR SYSTEMS, INC.
21 10850026568223 P1VC-035ANG-065 7-10094-05 ViperCross Support Catheter, 035", 65cm, Angled ViperCross CARDIOVASCULAR SYSTEMS, INC.
22 10850026568216 P1VC-035STR-150 7-10094-04 ViperCross Support Catheter, 035", 150cm, Straight ViperCross CARDIOVASCULAR SYSTEMS, INC.
23 10850026568209 P1VC-035STR-135 7-10094-03 ViperCross Support Catheter, 035", 135cm, Straight ViperCross CARDIOVASCULAR SYSTEMS, INC.
24 10850026568193 P1VC-035STR-090 7-10094-02 ViperCross Support Catheter, 035", 90cm, Straight ViperCross CARDIOVASCULAR SYSTEMS, INC.
25 10850026568186 P1VC-035STR-065 7-10094-01 ViperCross Support Catheter, 035", 65cm, Straight ViperCross CARDIOVASCULAR SYSTEMS, INC.
26 10850026568179 P1VC-018STR-150 7-10093-04 ViperCross Support Catheter, 018", 150cm, Straight ViperCross CARDIOVASCULAR SYSTEMS, INC.
27 10850026568162 P1VC-018STR-135 7-10093-03 ViperCross Support Catheter, 018", 135cm, Straight ViperCross CARDIOVASCULAR SYSTEMS, INC.
28 10850026568155 P1VC-018STR-090 7-10093-02 ViperCross Support Catheter, 018", 90cm, Straight ViperCross CARDIOVASCULAR SYSTEMS, INC.
29 10850026568148 P1VC-018STR-065 7-10093-01 ViperCross Support Catheter, 018", 65cm Straight ViperCross CARDIOVASCULAR SYSTEMS, INC.
30 10850026568131 P1VC-014STR-150 7-10092-02 ViperCross Support Catheter, 014", 150cm, Straight ViperCross CARDIOVASCULAR SYSTEMS, INC.
31 10850026568124 P1VC-014STR-135 7-10092-01 ViperCross Support Catheter, 014", 135cm, Straight ViperCross CARDIOVASCULAR SYSTEMS, INC.
32 10841156109141 IPN915843 5573 GuideLiner 8F GUIDELINER TELEFLEX INCORPORATED
33 10841156109134 IPN915842 5572 GuideLiner 7F GUIDELINER TELEFLEX INCORPORATED
34 10841156109127 IPN922787 5571 GuideLiner V3.5 6F GUIDELINER TELEFLEX INCORPORATED
35 10841156109110 IPN915840 5570 GuideLiner V3 5.5F GUIDELINER TELEFLEX INCORPORATED
36 10841156109097 IPN922914 5201 Twin-Pass Torque TWIN-PASS TELEFLEX INCORPORATED
37 10841156108953 IPN920313 5270 GuideLiner Coast,3.5,5.5F GUIDELINER TELEFLEX INCORPORATED
38 10841156108946 IPN920316 5273 GuideLiner Coast,3.5,8F GUIDELINER TELEFLEX INCORPORATED
39 10841156108939 IPN920315 5272 GuideLiner Coast,3.5,7F GUIDELINER TELEFLEX INCORPORATED
40 10841156108922 IPN920314 5271 GuideLiner Coast,3.5,6F GUIDELINER TELEFLEX INCORPORATED
41 10841156108786 IPN917518 5643 Turnpike Smooth, 150cm, TCT TURNPIKE TELEFLEX INCORPORATED
42 10841156108779 IPN917517 5642 Turnpike Smooth, 135cm, TCT TURNPIKE TELEFLEX INCORPORATED
43 10841156108762 IPN917516 5641 Turnpike Spiral, 150cm, TCT TURNPIKE TELEFLEX INCORPORATED
44 10841156108755 IPN917515 5640 Turnpike Spiral, 135cm, TCT TURNPIKE TELEFLEX INCORPORATED
45 10841156108748 IPN917514 5639 Turnpike LP, 150cm, TCT TURNPIKE TELEFLEX INCORPORATED
46 10841156108731 IPN917513 5638 Turnpike LP, 135cm, TCT TURNPIKE TELEFLEX INCORPORATED
47 10841156108724 IPN917512 5622 Turnpike Gold, 150cm, TCT TURNPIKE TELEFLEX INCORPORATED
48 10841156108717 IPN917511 5621 Turnpike Gold, 135cm, TCT TURNPIKE TELEFLEX INCORPORATED
49 10841156107475 IPN916131 5309 SuperCross 014 AT, 90 Degree XT, 150cm SUPERCROSS TELEFLEX INCORPORATED
50 10841156107468 IPN916130 5308 SuperCross 014 AT, 90 Degree XT, 130cm SUPERCROSS TELEFLEX INCORPORATED