Other products from "THERMOPEUTIX, INC."
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 M781S1835401501 S18/35-40-150 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
2 M781S1835201501 S18/35-20-150 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
3 M781S1435401501 S14/35-40-150 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
4 M781S1418601501 S14/18-60-150 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
5 M781P141201501 P14-120-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
6 M781S1435201501 S14/35-20-150 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
7 M781S1418401501 S14/18-40-150 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
8 M781S1418201701 S14/18-20-170 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
9 M781S1418201501 S14/18-20-150 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
10 M781P35601501 P35-60-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
11 M781P35401501 P35-40-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
12 M781P35201501 P35-20-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
13 M781P351201701 P35-120-170 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
14 M781P351201501 P35-120-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
15 M781P18601501 P18-60-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
16 M781P18401501 P18-40-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
17 M781P18201501 P18-20-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
18 M781P181201501 P18-120-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
19 M781P1460150HF1 P14-60-150HF The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
20 M781P14401501 P14-40-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
21 M781P1420150HF1 P14-20-150HF The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
22 M781P14120150HF1 P14-120-150HF The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
23 M781DFH80115901 DFH80-115/90 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
24 M781DFH80115801 DFH80-115/80 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
25 M781DFH60115901 DFH60-115/90 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
26 M781DFH60115801 DFH60-115/80 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
27 M781DFH10135901 DFH10-135/90 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
28 M781DFH10115901 DFH10-115/90 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
29 M781DFH10115801 DFH10-115/80 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
30 M781DF10115801 DF10-115/80 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
31 M7819680801 96-8080 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
32 M7819660601 96-6060 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
33 M7819645251 96-4525 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
34 M7819610101 96-1010 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
35 M7819445451 94-4545 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
36 M7819280801 92-8080 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
37 M7819260601 92-6060 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
38 M7819260251 92-6025 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
39 M7819245451 92-4545 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
40 M7819245251 92-4525 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
41 M7819210101 92-1010 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
42 M7819180801 91-8080 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
43 M7819180601 91-8060 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
44 M7819180451 91-8045 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
45 M7819180251 91-8025 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
46 M7819160601 91-6060 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
47 M7819160451 91-6045 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
48 M7819160251 91-6025 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
49 M7819145451 91-4545 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
50 M7819145251 91-4525 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlu The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
Other products with the same Product Code "DQY"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 00810170018565 BC0411XC-B BC0411XC Balloon Catheter Scepter XC MICROVENTION INC.
2 00810170018558 BC0420C-B BC0420C Balloon Catheter Scepter C MICROVENTION INC.
3 00810170018541 BC0415C-B BC0415C Balloon Catheter Scepter C MICROVENTION INC.
4 00810170018534 BC0410C-B BC0410C Balloon Catheter Scepter C MICROVENTION INC.
5 00810170016370 BC0411XC BC0411XC Balloon Catheter Scepter XC MICROVENTION INC.
6 00810170016165 MC272150S MC272150S Microcatheter Headway MICROVENTION INC.
7 00810170015823 BC0420C BC0420C Balloon Catheter Scepter C MICROVENTION INC.
8 00810170015816 BC0415C BC0415C Balloon Catheter Scepter C MICROVENTION INC.
9 00810170015809 BC0410C BC0410C Balloon Catheter Scepter C MICROVENTION INC.
10 00810170015519 MC172150JX MC172150JX Microcatheter Headway Advanced MICROVENTION INC.
11 00810170015502 MC172150STX MC172150STX Microcatheter Headway Advanced MICROVENTION INC.
12 00810170015496 MC17215045X MC17215045X Microcatheter Headway Advanced MICROVENTION INC.
13 00810170015489 MC17215090X MC17215090X Microcatheter Headway Advanced MICROVENTION INC.
14 00810170014857 MC212150S MC212150S Microcatheter Headway MICROVENTION INC.
15 00810170014413 MC162167S MC162167S Microcatheter Headway Duo MICROVENTION INC.
16 00810170014345 MC162156S MC162156S Microcatheter Headway Duo MICROVENTION INC.
17 00810170013751 MC172150SX MC172150SX Microcatheter Headway Advanced MICROVENTION INC.
18 00810170013744 MC172150S MC172150S Microcatheter Headway Advanced Soft MICROVENTION INC.
19 00810170013379 GC695BUHH GC695BUHH Guides Chaperon Guiding Catheter MICROVENTION INC.
20 00810170013362 GC695BUST GC695BUST Guides Chaperon Guiding Catheter MICROVENTION INC.
21 00810170013355 GC695BUSI GC695BUSI Guides Chaperon Guiding Catheter MICROVENTION INC.
22 00810170013348 GC695BUVT GC695BUVT Guides Chaperon Guiding Catheter MICROVENTION INC.
23 00810170013331 GC695BUJB GC695BUJB Guides Chaperon Guiding Catheter MICROVENTION INC.
24 00810170013324 GC695BU GC695BU Guides Chaperon Guiding Catheter MICROVENTION INC.
25 00810170013317 GC695M2HH GC695M2HH Guides Chaperon Guiding Catheter MICROVENTION INC.
26 00810170013300 GC695M2ST GC695M2ST Guides Chaperon Guiding Catheter MICROVENTION INC.
27 00810170013294 GC695M2SI GC695M2SI Guides Chaperon Guiding Catheter MICROVENTION INC.
28 00810170013287 GC695M1HH GC695M1HH Guides Chaperon Guiding Catheter MICROVENTION INC.
29 00810170013270 GC695M1ST GC695M1ST Guides Chaperon Guiding Catheter MICROVENTION INC.
30 00810170013263 GC695M1SI GC695M1SI Guides Chaperon Guiding Catheter MICROVENTION INC.
31 00810170013256 GC695STHH GC695STHH Guides Chaperon Guiding Catheter MICROVENTION INC.
32 00810170013249 GC695STST GC695STST Guides Chaperon Guiding Catheter MICROVENTION INC.
33 00810170013232 GC695STSI GC695STSI Guides Chaperon Guiding Catheter MICROVENTION INC.
34 00810170013225 GC595BUHH GC595BUHH Guides Chaperon Guiding Catheter MICROVENTION INC.
35 00810170013218 GC595BUST GC595BUST Guides Chaperon Guiding Catheter MICROVENTION INC.
36 00810170013201 GC595BUSI GC595BUSI Guides Chaperon Guiding Catheter MICROVENTION INC.
37 00810170013195 GC595BUVT GC595BUVT Guides Chaperon Guiding Catheter MICROVENTION INC.
38 00810170013188 GC595BUJB GC595BUJB Guides Chaperon Guiding Catheter MICROVENTION INC.
39 00810170013171 GC595BU GC595BU Guides Chaperon Guiding Catheter MICROVENTION INC.
40 00810170013164 GC595M2HH GC595M2HH Guides Chaperon Guiding Catheter MICROVENTION INC.
41 00810170013157 GC695M2VT GC695M2VT Guides Chaperon Guiding Catheter MICROVENTION INC.
42 00810170013140 GC695M2JB GC695M2JB Guides Chaperon Guiding Catheter MICROVENTION INC.
43 00810170013133 GC695M2 GC695M2 Guides Chaperon Guiding Catheter MICROVENTION INC.
44 00810170012877 GC595M2ST GC595M2ST Guides Chaperon Guiding Catheter MICROVENTION INC.
45 00810170012860 GC595M2SI GC595M2SI Guides Chaperon Guiding Catheter MICROVENTION INC.
46 00810170012853 GC595M1HH GC595M1HH Guides Chaperon Guiding Catheter MICROVENTION INC.
47 00810170012846 GC595M1ST GC595M1ST Guides Chaperon Guiding Catheter MICROVENTION INC.
48 00810170012839 GC595M1SI GC595M1SI Guides Chaperon Guiding Catheter MICROVENTION INC.
49 00810170012822 GC595STHH GC595STHH Guides Chaperon Guiding Catheter MICROVENTION INC.
50 00810170012815 GC595STST GC595STST Guides Chaperon Guiding Catheter MICROVENTION INC.