Other products from "THERMOPEUTIX, INC."
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 M781S1835401501 S18/35-40-150 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
2 M781S1835201501 S18/35-20-150 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
3 M781S1435401501 S14/35-40-150 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
4 M781S1418601501 S14/18-60-150 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
5 M781P141201501 P14-120-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
6 M781S1435201501 S14/35-20-150 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
7 M781S1418401501 S14/18-40-150 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
8 M781S1418201701 S14/18-20-170 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
9 M781S1418201501 S14/18-20-150 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
10 M781P35601501 P35-60-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
11 M781P35401501 P35-40-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
12 M781P35201501 P35-20-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
13 M781P351201701 P35-120-170 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
14 M781P351201501 P35-120-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
15 M781P18601501 P18-60-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
16 M781P18401501 P18-40-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
17 M781P18201501 P18-20-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
18 M781P181201501 P18-120-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
19 M781P1460150HF1 P14-60-150HF The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
20 M781P1440150HF1 P14-40-150HF The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
21 M781P14401501 P14-40-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
22 M781P14120150HF1 P14-120-150HF The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
23 M781DFH80115901 DFH80-115/90 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
24 M781DFH80115801 DFH80-115/80 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
25 M781DFH60115901 DFH60-115/90 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
26 M781DFH60115801 DFH60-115/80 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
27 M781DFH10135901 DFH10-135/90 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
28 M781DFH10115901 DFH10-115/90 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
29 M781DFH10115801 DFH10-115/80 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
30 M781DF10115801 DF10-115/80 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
31 M7819680801 96-8080 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
32 M7819660601 96-6060 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
33 M7819645251 96-4525 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
34 M7819610101 96-1010 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
35 M7819445451 94-4545 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
36 M7819280801 92-8080 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
37 M7819260601 92-6060 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
38 M7819260251 92-6025 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
39 M7819245451 92-4545 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
40 M7819245251 92-4525 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
41 M7819210101 92-1010 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
42 M7819180801 91-8080 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
43 M7819180601 91-8060 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
44 M7819180451 91-8045 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
45 M7819180251 91-8025 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
46 M7819160601 91-6060 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
47 M7819160451 91-6045 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
48 M7819160251 91-6025 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
49 M7819145451 91-4545 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
50 M7819145251 91-4525 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlu The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
Other products with the same Product Code "DQY"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 M6651003600 100360 Femoral Venous Catheter, Silicone Axiom® Femoral Venous AXIOM MEDICAL, INCORPORATED
2 M6651003200 100320 Femoral Venous Catheter, Silicone Axiom® Femoral Venous AXIOM MEDICAL, INCORPORATED
3 M6651002800 100280 Femoral Venous Catheter, Silicone Axiom® Femoral Venous AXIOM MEDICAL, INCORPORATED
4 M20688020 8802 The PiggyBack is intended to be used with guidewires to access the peripheral va The PiggyBack is intended to be used with guidewires to access the peripheral vasculature and to facilitate placement of interventional devices. PiggyBack® wire converter VASCULAR SOLUTIONS, INC.
5 M20688010 8801 The PiggyBack is intended to be used with guidewires to access the peripheral va The PiggyBack is intended to be used with guidewires to access the peripheral vasculature and to facilitate placement of interventional devices. PiggyBack® wire converter VASCULAR SOLUTIONS, INC.
6 M20688000 8800 PiggyBack® wire converter VASCULAR SOLUTIONS, INC.
7 M20683020 8302 The MICRO Elite Snare is intended for use in the retrieval and manipulation of a The MICRO Elite Snare is intended for use in the retrieval and manipulation of atraumatic foreign bodies located in the coronary and peripheral cardiovascular system and the extra-cranial neurovascular anatomy. Micro Elite™ snare VASCULAR SOLUTIONS, INC.
8 M20683010 8301 The MICRO Elite Snare is intended for use in the retrieval and manipulation of a The MICRO Elite Snare is intended for use in the retrieval and manipulation of atraumatic foreign bodies located in the coronary and peripheral cardiovascular system and the extra-cranial neurovascular anatomy. Micro Elite™ snare VASCULAR SOLUTIONS, INC.
9 M20683000 8300 Micro Elite™ snare VASCULAR SOLUTIONS, INC.
10 M20658230 5823 The Venture catheter is indicated for directing, steering, controlling, and supp The Venture catheter is indicated for directing, steering, controlling, and supporting a guidewire to access discrete regions of the peripheral vasculature. It may also be used for manual delivery of saline solution or diagnostic contrast agents. Venture® 038 catheter VASCULAR SOLUTIONS, INC.
11 M20658220 5822 The Venture catheter is indicated for directing, steering, controlling, and supp The Venture catheter is indicated for directing, steering, controlling, and supporting a guidewire to access discrete regions of the coronary and peripheral vasculature. It may also be used for manual delivery of saline solution or diagnostic contrast agents. Venture® CS catheter VASCULAR SOLUTIONS, INC.
12 M20658210 5821 The Venture catheter is indicated for directing, steering, controlling, and supp The Venture catheter is indicated for directing, steering, controlling, and supporting a guidewire to access discrete regions of the coronary and peripheral vasculature. It may also be used for manual delivery of saline solution or diagnostic contrast agents. Venture® OTW catheter VASCULAR SOLUTIONS, INC.
13 M20658200 5820 Venture® RX catheter VASCULAR SOLUTIONS, INC.
14 M20657130 5713 The Minnie support catheters are intended to be used in conjunction with steerab The Minnie support catheters are intended to be used in conjunction with steerable guidewires in order to access discrete regions of the arterial and/or coronary vasculature. They may be used to facilitate placement and exchange of guidewires and other interventional devices. The Minnie support catheters also may be used to subselectively infuse/deliver therapeutic agents. Minnie® support catheter VASCULAR SOLUTIONS, INC.
15 M20657120 5712 The Minnie support catheters are intended to be used in conjunction with steerab The Minnie support catheters are intended to be used in conjunction with steerable guidewires in order to access discrete regions of the arterial and/or coronary vasculature. They may be used to facilitate placement and exchange of guidewires and other interventional devices. The Minnie support catheters also may be used to subselectively infuse/deliver therapeutic agents. Minnie® support catheter VASCULAR SOLUTIONS, INC.
16 M20657110 5711 The Minnie support catheters are intended to be used in conjunction with steerab The Minnie support catheters are intended to be used in conjunction with steerable guidewires in order to access discrete regions of the arterial and/or coronary vasculature. They may be used to facilitate placement and exchange of guidewires and other interventional devices. The Minnie support catheters also may be used to subselectively infuse/deliver therapeutic agents. Minnie® support catheter VASCULAR SOLUTIONS, INC.
17 M20657100 5710 The Minnie support catheters are intended to be used in conjunction with steerab The Minnie support catheters are intended to be used in conjunction with steerable guidewires in order to access discrete regions of the arterial and/or coronary vasculature. They may be used to facilitate placement and exchange of guidewires and other interventional devices. The Minnie support catheters also may be used to subselectively infuse/deliver therapeutic agents. Minnie® support catheter VASCULAR SOLUTIONS, INC.
18 M20657080 5708 The Minnie support catheters are intended to be used in conjunction with steerab The Minnie support catheters are intended to be used in conjunction with steerable guidewires in order to access discrete regions of the arterial and/or coronary vasculature. They may be used to facilitate placement and exchange of guidewires and other interventional devices. The Minnie support catheters also may be used to subselectively infuse/deliver therapeutic agents. Minnie® support catheter VASCULAR SOLUTIONS, INC.
19 M20657070 5707 The Minnie support catheters are intended to be used in conjunction with steerab The Minnie support catheters are intended to be used in conjunction with steerable guidewires in order to access discrete regions of the arterial and/or coronary vasculature. They may be used to facilitate placement and exchange of guidewires and other interventional devices. The Minnie support catheters also may be used to subselectively infuse/deliver therapeutic agents. Minnie® support catheter VASCULAR SOLUTIONS, INC.
20 M20657060 5706 The Minnie support catheters are intended to be used in conjunction with steerab The Minnie support catheters are intended to be used in conjunction with steerable guidewires in order to access discrete regions of the arterial and/or coronary vasculature. They may be used to facilitate placement and exchange of guidewires and other interventional devices. The Minnie support catheters also may be used to subselectively infuse/deliver therapeutic agents. Minnie® support catheter VASCULAR SOLUTIONS, INC.
21 M20657050 5705 The Minnie support catheters are intended to be used in conjunction with steerab The Minnie support catheters are intended to be used in conjunction with steerable guidewires in order to access discrete regions of the arterial and/or coronary vasculature. They may be used to facilitate placement and exchange of guidewires and other interventional devices. The Minnie support catheters also may be used to subselectively infuse/deliver therapeutic agents. Minnie® support catheter VASCULAR SOLUTIONS, INC.
22 M20657040 5704 The Minnie support catheters are intended to be used in conjunction with steerab The Minnie support catheters are intended to be used in conjunction with steerable guidewires in order to access discrete regions of the arterial and/or coronary vasculature. They may be used to facilitate placement and exchange of guidewires and other interventional devices. The Minnie support catheters also may be used to subselectively infuse/deliver therapeutic agents. Minnie® support catheter VASCULAR SOLUTIONS, INC.
23 M20657030 5703 The Minnie support catheters are intended to be used in conjunction with steerab The Minnie support catheters are intended to be used in conjunction with steerable guidewires in order to access discrete regions of the arterial and/or coronary vasculature. They may be used to facilitate placement and exchange of guidewires and other interventional devices. The Minnie support catheters also may be used to subselectively infuse/deliver therapeutic agents. Minnie® support catheter VASCULAR SOLUTIONS, INC.
24 M20657020 5702 The Minnie support catheters are intended to be used in conjunction with steerab The Minnie support catheters are intended to be used in conjunction with steerable guidewires in order to access discrete regions of the arterial and/or coronary vasculature. They may be used to facilitate placement and exchange of guidewires and other interventional devices. The Minnie support catheters also may be used to subselectively infuse/deliver therapeutic agents. Minnie® support catheter VASCULAR SOLUTIONS, INC.
25 M20657010 5701 The Minnie support catheters are intended to be used in conjunction with steerab The Minnie support catheters are intended to be used in conjunction with steerable guidewires in order to access discrete regions of the arterial and/or coronary vasculature. They may be used to facilitate placement and exchange of guidewires and other interventional devices. The Minnie support catheters also may be used to subselectively infuse/deliver therapeutic agents. Minnie® support catheter VASCULAR SOLUTIONS, INC.
26 M20657000 5700 Minnie® support catheter VASCULAR SOLUTIONS, INC.
27 M20656430 5643 The Turnpike catheters are intended to be used to access discrete regions of the The Turnpike catheters are intended to be used to access discrete regions of the coronary and/or peripheral vasculature. They may be used to facilitate placement and exchange of guidewires and to subselectively infuse/deliver diagnostic and therapeutic agents. Turnpike® catheter VASCULAR SOLUTIONS, INC.
28 M20656420 5642 The Turnpike catheters are intended to be used to access discrete regions of the The Turnpike catheters are intended to be used to access discrete regions of the coronary and/or peripheral vasculature. They may be used to facilitate placement and exchange of guidewires and to subselectively infuse/deliver diagnostic and therapeutic agents. Turnpike® catheter VASCULAR SOLUTIONS, INC.
29 M20656410 5641 The Turnpike catheters are intended to be used to access discrete regions of the The Turnpike catheters are intended to be used to access discrete regions of the coronary and/or peripheral vasculature. They may be used to facilitate placement and exchange of guidewires and to subselectively infuse/deliver diagnostic and therapeutic agents. Turnpike® Spiral catheter VASCULAR SOLUTIONS, INC.
30 M20656400 5640 The Turnpike catheters are intended to be used to access discrete regions of the The Turnpike catheters are intended to be used to access discrete regions of the coronary and/or peripheral vasculature. They may be used to facilitate placement and exchange of guidewires and to subselectively infuse/deliver diagnostic and therapeutic agents. Turnpike® Spiral catheter VASCULAR SOLUTIONS, INC.
31 M20656390 5639 The Turnpike catheters are intended to be used to access discrete regions of the The Turnpike catheters are intended to be used to access discrete regions of the coronary and/or peripheral vasculature. They may be used to facilitate placement and exchange of guidewires and to subselectively infuse/deliver diagnostic and therapeutic agents. Turnpike® LP catheter VASCULAR SOLUTIONS, INC.
32 M20656380 5638 The Turnpike catheters are intended to be used to access discrete regions of the The Turnpike catheters are intended to be used to access discrete regions of the coronary and/or peripheral vasculature. They may be used to facilitate placement and exchange of guidewires and to subselectively infuse/deliver diagnostic and therapeutic agents. Turnpike® LP catheter VASCULAR SOLUTIONS, INC.
33 M20656220 5622 The Turnpike catheters are intended to be used to access discrete regions of the The Turnpike catheters are intended to be used to access discrete regions of the coronary and/or peripheral vasculature. They may be used to facilitate placement and exchange of guidewires and to subselectively infuse/deliver diagnostic and therapeutic agents. Turnpike® Gold catheter VASCULAR SOLUTIONS, INC.
34 M20656210 5621 Turnpike® Gold catheter VASCULAR SOLUTIONS, INC.
35 M20655760 5576 GuideLiner XL catheter is intended to be used in conjunction with a guide cathet GuideLiner XL catheter is intended to be used in conjunction with a guide catheter to access discrete regions of the coronary and/or peripheral vasculature, and to facilitate placement of interventional devices. GuideLiner® XL catheter VASCULAR SOLUTIONS, INC.
36 M20655730 5573 GuideLiner catheters are intended to be used in conjunction with guide catheters GuideLiner catheters are intended to be used in conjunction with guide catheters to access discrete regions of the coronary and/or peripheral vasculature, and to facilitate placement of interventional devices. GuideLiner® V3 catheter VASCULAR SOLUTIONS, INC.
37 M20655720 5572 GuideLiner catheters are intended to be used in conjunction with guide catheters GuideLiner catheters are intended to be used in conjunction with guide catheters to access discrete regions of the coronary and/or peripheral vasculature, and to facilitate placement of interventional devices. GuideLiner® V3 catheter VASCULAR SOLUTIONS, INC.
38 M20655710 5571 GuideLiner catheters are intended to be used in conjunction with guide catheters GuideLiner catheters are intended to be used in conjunction with guide catheters to access discrete regions of the coronary and/or peripheral vasculature, and to facilitate placement of interventional devices. GuideLiner® V3 catheter VASCULAR SOLUTIONS, INC.
39 M20655700 5570 GuideLiner catheters are intended to be used in conjunction with guide catheters GuideLiner catheters are intended to be used in conjunction with guide catheters to access discrete regions of the coronary and/or peripheral vasculature, and to facilitate placement of interventional devices. GuideLiner® V3 catheter VASCULAR SOLUTIONS, INC.
40 M20655690 5569 GuideLiner® V3 catheter VASCULAR SOLUTIONS, INC.
41 M20655680 5568 The TrapLiner catheter is intended for use in conjunction with guide catheters t The TrapLiner catheter is intended for use in conjunction with guide catheters to access discrete regions of the coronary and/or peripheral vasculature, to facilitate placement of interventional device while maintaining the position of a guidewire within the vasculature. TrapLiner™ catheter VASCULAR SOLUTIONS, INC.
42 M20655670 5567 The TrapLiner catheter is intended for use in conjunction with guide catheters t The TrapLiner catheter is intended for use in conjunction with guide catheters to access discrete regions of the coronary and/or peripheral vasculature, to facilitate placement of interventional device while maintaining the position of a guidewire within the vasculature. TrapLiner™ catheter VASCULAR SOLUTIONS, INC.
43 M20655660 5566 The TrapLiner catheter is intended for use in conjunction with guide catheters t The TrapLiner catheter is intended for use in conjunction with guide catheters to access discrete regions of the coronary and/or peripheral vasculature, to facilitate placement of interventional device while maintaining the position of a guidewire within the vasculature. TrapLiner™ catheter VASCULAR SOLUTIONS, INC.
44 M20654730 5473 Navigation catheters are intended to be used in conjunction with guide catheters Navigation catheters are intended to be used in conjunction with guide catheters to access discrete regions of the coronary and/or peripheral vasculature, and to facilitate placement of guidewires and other interventional devices. GuideLiner® Navigation™ catheter VASCULAR SOLUTIONS, INC.
45 M20654720 5472 Navigation catheters are intended to be used in conjunction with guide catheters Navigation catheters are intended to be used in conjunction with guide catheters to access discrete regions of the coronary and/or peripheral vasculature, and to facilitate placement of guidewires and other interventional devices. GuideLiner® Navigation™ catheter VASCULAR SOLUTIONS, INC.
46 M20654710 5471 Navigation catheters are intended to be used in conjunction with guide catheters Navigation catheters are intended to be used in conjunction with guide catheters to access discrete regions of the coronary and/or peripheral vasculature, and to facilitate placement of guidewires and other interventional devices. GuideLiner® Navigation™ catheter VASCULAR SOLUTIONS, INC.
47 M20654700 5470 GuideLiner® Navigation™ catheter VASCULAR SOLUTIONS, INC.
48 M20653410 5341 The SuperCross microcatheter is intended to be used in conjunction with steerabl The SuperCross microcatheter is intended to be used in conjunction with steerable guidewires to access discrete regions of the coronary and/or peripheral vasculature. It may be used to facilitate placement and exchange of guidewires and other interventional devices and to subselectively infuse/deliver diagnostic and therapeutic agents. SuperCross™ FT microcatheter VASCULAR SOLUTIONS, INC.
49 M20653400 5340 The SuperCross microcatheter is intended to be used in conjunction with steerabl The SuperCross microcatheter is intended to be used in conjunction with steerable guidewires to access discrete regions of the coronary and/or peripheral vasculature. It may be used to facilitate placement and exchange of guidewires and other interventional devices and to subselectively infuse/deliver diagnostic and therapeutic agents. SuperCross™ FT microcatheter VASCULAR SOLUTIONS, INC.
50 M20653090 5309 The SuperCross microcatheter is intended to be used in conjunction with steerabl The SuperCross microcatheter is intended to be used in conjunction with steerable guidewires to access discrete regions of the coronary and/or peripheral vasculature. It may be used to facilitate placement and exchange of guidewires and other interventional devices and to subselectively infuse/deliver diagnostic and therapeutic agents. SuperCross™ AT microcatheter VASCULAR SOLUTIONS, INC.