No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 M781S1835401501 S18/35-40-150 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
2 M781S1835201501 S18/35-20-150 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
3 M781S1435401501 S14/35-40-150 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
4 M781S1418601501 S14/18-60-150 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
5 M781S1435201501 S14/35-20-150 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
6 M781S1418401501 S14/18-40-150 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
7 M781S1418201701 S14/18-20-170 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
8 M781S1418201501 S14/18-20-150 The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine The Secondi™ Support Catheter is a dual lumen catheter with an integrated spine wire and two guidewire lumens designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one proximally located guidewire for another while maintaining access to the distal vasculature over a second distal guidewire. The Secondi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of each of the catheter’s guide wire lumens. DQY Catheter, Percutaneous 2 Secondi™ Support Catheter
9 M781P35601501 P35-60-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
10 M781P35401501 P35-40-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
11 M781P35201501 P35-20-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
12 M781P351201701 P35-120-170 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
13 M781P351201501 P35-120-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
14 M781P18601501 P18-60-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
15 M781P18401501 P18-40-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
16 M781P18201501 P18-20-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
17 M781P181201501 P18-120-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
18 M781P1460150HF1 P14-60-150HF The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
19 M781P1440150HF1 P14-40-150HF The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
20 M781P14401501 P14-40-150 The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
21 M781P1420150HF1 P14-20-150HF The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
22 M781P14120150HF1 P14-120-150HF The Primi™ Support Catheter is a single lumen catheter with an integrated spine The Primi™ Support Catheter is a single lumen catheter with an integrated spine wire and guidewire lumen designed for use in the peripheral vasculature. The catheter provides support for guidewires during interventional procedures and allows for the exchange of one distally located guidewire for another while maintaining access to the distal vasculature. The Primi™ Support Catheter has a hydrophilic coating on the distal portion of the catheter, and is compatible with various guidewire diameters and lengths. The catheter has a single radiopaque marker band located at the distal tip of the catheter. DQY Catheter, Percutaneous 2 Primi™ Support Catheter
23 M781DFH80115901 DFH80-115/90 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
24 M781DFH80115801 DFH80-115/80 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
25 M781DFH60115901 DFH60-115/90 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
26 M781DFH60115801 DFH60-115/80 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
27 M781DFH10135901 DFH10-135/90 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
28 M781DFH10115901 DFH10-115/90 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
29 M781DFH10115801 DFH10-115/80 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
30 M781DF10115801 DF10-115/80 The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TwinFlo™ Catheter
31 M7819680801 96-8080 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
32 M7819660601 96-6060 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
33 M7819645251 96-4525 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
34 M7819610101 96-1010 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
35 M7819445451 94-4545 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
36 M7819280801 92-8080 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
37 M7819260601 92-6060 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
38 M7819260251 92-6025 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
39 M7819245451 92-4545 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
40 M7819245251 92-4525 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
41 M7819210101 92-1010 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
42 M7819180801 91-8080 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
43 M7819180601 91-8060 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
44 M7819180451 91-8045 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
45 M7819180251 91-8025 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
46 M7819160601 91-6060 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
47 M7819160451 91-6045 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
48 M7819160251 91-6025 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
49 M7819145451 91-4545 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
50 M7819145251 91-4525 The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlu The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. MJN Catheter, Intravascular Occluding, Temporary 2 TAPAS® Catheter
Other products with the same Product Code "DQY"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 00643169996175 SC-035-150 PS SC-035-150 TRAILBLAZER V04 TrailBlazer™ COVIDIEN LP
2 00643169996168 SC-035-135 PS SC-035-135 TRAILBLAZER V04 TrailBlazer™ COVIDIEN LP
3 00643169996151 SC-035-090 PS SC-035-090 TRAILBLAZER V04 TrailBlazer™ COVIDIEN LP
4 00643169996144 SC-035-065 PS SC-035-065 TRAILBLAZER V04 TrailBlazer™ COVIDIEN LP
5 00643169996137 SC-018-150 PS SC-018-150 TRAILBLAZER V04 TrailBlazer™ COVIDIEN LP
6 00643169996120 SC-018-135 PS SC-018-135 TRAILBLAZER V04 TrailBlazer™ COVIDIEN LP
7 00643169996113 SC-018-090 PS SC-018-090 TRAILBLAZER V04 TrailBlazer™ COVIDIEN LP
8 00643169996106 SC-014-150 PS SC-014-150 TRAILBLAZER V04 TrailBlazer™ COVIDIEN LP
9 00643169996090 SC-014-135 PS SC-014-135 TRAILBLAZER V04 TrailBlazer™ COVIDIEN LP
10 00643169974593 AB35W12060135 PTA AB35W12060135 EVERCROSS 035 V08 EverCross™ EV3, INC
11 00643169974586 AB35W12060080 PTA AB35W12060080 EVERCROSS 035 V08 EverCross™ EV3, INC
12 00643169974579 AB35W12040135 PTA AB35W12040135 EVERCROSS 035 V08 EverCross™ EV3, INC
13 00643169974562 AB35W12040080 PTA AB35W12040080 EVERCROSS 035 V08 EverCross™ EV3, INC
14 00643169974555 AB35W12020135 PTA AB35W12020135 EVERCROSS 035 V08 EverCross™ EV3, INC
15 00643169974548 AB35W12020080 PTA AB35W12020080 EVERCROSS 035 V08 EverCross™ EV3, INC
16 00643169974531 AB35W10060135 PTA AB35W10060135 EVERCROSS 035 V08 EverCross™ EV3, INC
17 00643169974524 AB35W10060080 PTA AB35W10060080 EVERCROSS 035 V08 EverCross™ EV3, INC
18 00643169974517 AB35W10040135 PTA AB35W10040135 EVERCROSS 035 V08 EverCross™ EV3, INC
19 00643169974500 AB35W10040080 PTA AB35W10040080 EVERCROSS 035 V08 EverCross™ EV3, INC
20 00643169974494 AB35W10030135 PTA AB35W10030135 EVERCROSS 035 V08 EverCross™ EV3, INC
21 00643169974487 AB35W10030080 PTA AB35W10030080 EVERCROSS 035 V08 EverCross™ EV3, INC
22 00643169974470 AB35W10020135 PTA AB35W10020135 EVERCROSS 035 V08 EverCross™ EV3, INC
23 00643169974463 AB35W10020080 PTA AB35W10020080 EVERCROSS 035 V08 EverCross™ EV3, INC
24 00643169974456 AB35W09080135 PTA AB35W09080135 EVERCROSS 035 V08 EverCross™ EV3, INC
25 00643169974449 AB35W09080080 PTA AB35W09080080 EVERCROSS 035 V08 EverCross™ EV3, INC
26 00643169974432 AB35W09060135 PTA AB35W09060135 EVERCROSS 035 V08 EverCross™ EV3, INC
27 00643169974425 AB35W09060080 PTA AB35W09060080 EVERCROSS 035 V08 EverCross™ EV3, INC
28 00643169974418 AB35W09040135 PTA AB35W09040135 EVERCROSS 035 V08 EverCross™ EV3, INC
29 00643169974401 AB35W09040080 TA AB35W09040080 EVERCROSS 035 V08 EverCross™ EV3, INC
30 00643169974395 AB35W09030135 PTA AB35W09030135 EVERCROSS 035 V08 EverCross™ EV3, INC
31 00643169974388 AB35W09030080 PTA AB35W09030080 EVERCROSS 035 V08 EverCross™ EV3, INC
32 00643169974371 AB35W09020135 PTA AB35W09020135 EVERCROSS 035 V08 EverCross™ EV3, INC
33 00643169974364 AB35W09020080 PTA AB35W09020080 EVERCROSS 035 V08 EverCross™ EV3, INC
34 00643169974357 AB35W08080135 PTA AB35W08080135 EVERCROSS 035 V08 EverCross™ EV3, INC
35 00643169974340 AB35W08080080 PTA AB35W08080080 EVERCROSS 035 V08 EverCross™ EV3, INC
36 00643169974333 AB35W08060135 PTA AB35W08060135 EVERCROSS 035 V08 EverCross™ EV3, INC
37 00643169974326 AB35W08060080 PTA AB35W08060080 EVERCROSS 035 V08 EverCross™ EV3, INC
38 00643169974319 AB35W08060040 PTA AB35W08060040 EVERCROSS 035 V08 EverCross™ EV3, INC
39 00643169974302 AB35W08040135 PTA AB35W08040135 EVERCROSS 035 V08 EverCross™ EV3, INC
40 00643169974296 AB35W08040080 PTA AB35W08040080 EVERCROSS 035 V08 EverCross™ EV3, INC
41 00643169974289 AB35W08040040 PTA AB35W08040040 EVERCROSS 035 V08 EverCross™ EV3, INC
42 00643169974272 AB35W08030135 PTA AB35W08030135 EVERCROSS 035 V08 EverCross™ EV3, INC
43 00643169974265 AB35W08030080 PTA AB35W08030080 EVERCROSS 035 V08 EverCross™ EV3, INC
44 00643169974258 AB35W08020135 PTA AB35W08020135 EVERCROSS 035 V08 EverCross™ EV3, INC
45 00643169974241 AB35W08020080 PTA AB35W08020080 EVERCROSS 035 V08 EverCross™ EV3, INC
46 00643169974234 AB35W08020040 PTA AB35W08020040 EVERCROSS 035 V08 EverCross™ EV3, INC
47 00643169974227 AB35W07200135 PTA AB35W07200135 EVERCROSS 035 V08 EverCross™ EV3, INC
48 00643169974210 AB35W07200080 PTA AB35W07200080 EVERCROSS 035 V08 EverCross™ EV3, INC
49 00643169974203 AB35W07150135 PTA AB35W07150135 EVERCROSS 035 V08 EverCross™ EV3, INC
50 00643169974197 AB35W07150080 PTA AB35W07150080 EVERCROSS 035 V08 EverCross™ EV3, INC