No | Primary DI | Version or Model | Catalog Number | Device Description | Product Code | Product Code Name | Device Class | Brand Name |
---|---|---|---|---|---|---|---|---|
1 | M697N600016301 | N60001630 | 1/4" BOX CONNECT/JACOBS CHUCK ADAPTER | HWE | INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT | 1 | Silex Sacroiliac Joint Fusion System | |
2 | M697N600004721 | N60000472 | Capless Screw System Ratcheting T-handle | HXC | WRENCH | 1 | Silex Sacroiliac Joint Fusion System | |
3 | M697CN6000441 | CN60-0044 | Specialty Cervical Distractor - Calix | HWB | EXTRACTOR | 1 | Calix Spinal Implant System | |
4 | M697C07902661 | C079-0266 | SPECIAL 12.5mm GRAFT FUNNEL ASSEMBLY | HXG | Tamp | 1 | Silex Sacroiliac Joint Fusion System | |
5 | M697C07902651 | C079-0265 | SPECIAL GRAFT TAMP | HXG | Tamp | 1 | Silex Sacroiliac Joint Fusion System | |
6 | M697C07902641 | C079-0264 | SPECIAL 7mm ADJUSTMENT IMPLANT DRIVER, CANNULATED | HXX | Screwdriver | 1 | Silex Sacroiliac Joint Fusion System | |
7 | M697C07902631 | C079-0263 | Special Guide Handle Assembly, Soft Tissue Shield | FZX | Guide, Surgical, Instrument | 1 | Silex Sacroiliac Joint Fusion System | |
8 | M697C07902621 | C079-0262 | Special Instrument 8mm x 25cm Bone Funnel Assembly | HXG | Tamp | 1 | Silex Sacroiliac Joint Fusion System | |
9 | M697C07902611 | C079-0261 | Special Instrument 8mm x 25cm Tamp Assembly | HXG | Tamp | 1 | Silex Sacroiliac Joint Fusion System | |
10 | M697C07900581 | C079-0058 | Specialty Silex 800 mm Trocar Steinman Pin w/breakaway pt @500mm | GDF | GUIDE, NEEDLE, SURGICAL | Silex Sacroiliac Joint Fusion System | ||
11 | M697C07900571 | C079-0057 | Specialty Silex Aggressive Tip 7mm drill | HTW | BIT, DRILL | 1 | Silex Sacroiliac Joint Fusion System | |
12 | M697C07900561 | C079-0056 | Specialty Silex Aggressive Tip 12.5mm Drill | HTW | Bit, Drill | 1 | Silex Sacroiliac Joint Fusion System | |
13 | M697C07900551 | C079-0055 | Specialty Silex 800 mm Steinmann pin case | GDF | GUIDE, NEEDLE, SURGICAL | 1 | Silex Sacroiliac Joint Fusion System | |
14 | M697C07900531 | C079-0053 | Silex Tissue Spreader Assembly | EMF | KNIFE, SURGICAL | 1 | Silex Sacroiliac Joint Fusion System | |
15 | M697C07900521 | C079-0052 | Specialty Fully Threaded 2.4mm x 300mm Steinmann Pin | GDF | GUIDE, NEEDLE, SURGICAL | 1 | Silex Sacroiliac Joint Fusion System | |
16 | M697C07900501 | C079-0050 | Specialty Jamshidi Awl Insert | HWJ | AWL | 1 | Silex Sacroiliac Joint Fusion System | |
17 | M697C07900491 | C079-0049 | Specialty Cannulated Awl | HWJ | AWL | 1 | Silex Sacroiliac Joint Fusion System | |
18 | M697C07900481 | C079-0048 | Specialty 800mm Long Steinmann Pinn | GDF | GUIDE, NEEDLE, SURGICAL | 1 | Silex Sacroiliac Joint Fusion System | |
19 | M697C07900441 | C079-0044 | Specialty Silex Drill | HTW | BIT, DRILL | 1 | Silex Sacroiliac Joint Fusion System | |
20 | M697C07900411 | C079-0041 | SPECIALTY THREADED STEINMANN PIN 2.4 X 500MM TROCAR TIP | GDF | GUIDE, NEEDLE, SURGICAL | 1 | Silex Sacroiliac Joint Fusion System | |
21 | M697C07900391 | C079-0039 | SPECIALTY #3 STS MORE AGGRESSIVE TIP | FZX | Guide, surgical, instrument | 1 | Silex Sacroiliac Joint Fusion System | |
22 | M697C07900381 | C079-0038 | SPECIALTY #2 STS MORE AGGRESSIVE TIP | HWX | TAP, BONE | 1 | Silex Sacroiliac Joint Fusion System | |
23 | M697C07900371 | C079-0037 | SPECIALTY SILEX WASHER REMOVAL TOOL ASSEMBLY | HWB | EXTRACTOR | 1 | Silex Sacroiliac Joint Fusion System | |
24 | M697C07900301 | C079-0030 | SPECIALTY GUIDE TUBE HANDLE | FZX | Guide, surgical, instrument | 1 | Silex Sacroiliac Joint Fusion System | |
25 | M697C07900271 | C079-0027 | Specialty Silex 12.5mm Tap Aggressive Tip | HWX | TAP, BONE | 1 | Silex Sacroiliac Joint Fusion System | |
26 | M697C07900261 | C079-0026 | CUSTOM IMPACTION DRIVER | HWA | IMPACTOR | 1 | Silex Sacroiliac Joint Fusion System | |
27 | M697C07900251 | C079-0025 | Specialty Silex #3 STS | FZX | Guide, surgical, instrument | 1 | Silex Sacroiliac Joint Fusion System | |
28 | M697C07900241 | C079-0024 | Specialty Silex #2 STS | FZX | Guide, surgical, instrument | 1 | Silex Sacroiliac Joint Fusion System | |
29 | M697C07900111 | C079-0011 | SPECIALTY 12.5 mm IMPLANT DRIVER | HXX | SCREWDRIVER | 1 | Silex Sacroiliac Joint Fusion System | |
30 | M697C07900031 | C079-0003 | SPECIAL 12.5MM TAP | HWX | TAP, BONE | 1 | Silex Sacroiliac Joint Fusion System | |
31 | M697C07900021 | C079-0002 | SPECIAL 12.5MM DRILL | HTW | BIT, DRILL | 1 | Silex Sacroiliac Joint Fusion System | |
32 | M697C07900011 | C079-0001 | CUSTOM #1 SOFT TISSUE SHIELD | FZX | Guide, surgical, instrument | 1 | Silex Sacroiliac Joint Fusion System | |
33 | M697C07600061 | C076-0006 | Specialty Luer Lock adapter for Osteosponge putty syringe | MJG | DEVICE, PERCUTANEOUS, BIOPSY | 1 | Zyfix Spinal Facet Screw System | |
34 | M697C07600051 | C076-0005 | Specialty Luer Lock adapter for Osteosponge putty syringe | MJG | DEVICE, PERCUTANEOUS, BIOPSY | 1 | Zyfix Spinal Facet Screw System | |
35 | M697C07600041 | C076-0004 | Specialty Luer Lock adapter for Osteosponge putty syringe | MJG | DEVICE, PERCUTANEOUS, BIOPSY | 1 | Zyfix Spinal Facet Screw System | |
36 | M697X07900341 | X079-0034 | 7mm DRILL BIT, CANNULATED | HTW | BIT, DRILL | 1 | Silex Sacroiliac Joint Fusion System | |
37 | 00849777011969 | C024-0025-PTYV | ONE (1) PACKAGE - CONTAINING 2.5cc | MBP,MQV | Filler, Bone Void, Osteoinduction (W/O Human Growth Factor),Filler, Bone Void, C Filler, Bone Void, Osteoinduction (W/O Human Growth Factor),Filler, Bone Void, Calcium Compound | 2 | CuriGraft DBM Putty, 2.5cc | |
38 | 00849777011921 | IFLX-CR-05 | ONE (1) PACKAGE - CONTAINING 5.0cc | MBP,MQV | Filler, Bone Void, Osteoinduction (W/O Human Growth Factor),Filler, Bone Void, C Filler, Bone Void, Osteoinduction (W/O Human Growth Factor),Filler, Bone Void, Calcium Compound | 2 | Influx Plus Crunch 5.0cc - Syringe | |
39 | 00849777011754 | MFC-5 | ONE (1) PACKAGE - CONTAINING 5.0cc | MBP,MQV | Filler, Bone Void, Osteoinduction (W/O Human Growth Factor),Filler, Bone Void, C Filler, Bone Void, Osteoinduction (W/O Human Growth Factor),Filler, Bone Void, Calcium Compound | 2 | MAXX™ Fuse DBM Putty with Chips 5cc | |
40 | 00849777011570 | X055-0045 | 10.0cc (Jar) | MBP,MQV | Filler, Bone Void, Osteoinduction (W/O Human Growth Factor),Filler, Bone Void, C Filler, Bone Void, Osteoinduction (W/O Human Growth Factor),Filler, Bone Void, Calcium Compound | 2 | DMB Putty 10.0cc | |
41 | 00849777010535 | IS59P025 | ONE (1) PACKAGE - CONTAINING 2.5cc | MBP,MQV | Filler, Bone Void, Osteoinduction (W/O Human Growth Factor),Filler, Bone Void, C Filler, Bone Void, Osteoinduction (W/O Human Growth Factor),Filler, Bone Void, Calcium Compound | 2 | DBM Putty 2.5cc-Syringe | |
42 | 00849777010184 | BX-600-005-M | ONE (1) PACKAGE - CONTAINING 0.5cc | MBP,MQV | Filler, Bone Void, Osteoinduction (W/O Human Growth Factor),Filler, Bone Void, C Filler, Bone Void, Osteoinduction (W/O Human Growth Factor),Filler, Bone Void, Calcium Compound | 2 | DBM Putty 0.5cc | |
43 | 00849777009683 | BM895005 | ONE (1) PACKAGE - CONTAINING 0.5cc | MBP,MQV | Filler, Bone Void, Osteoinduction (W/O Human Growth Factor),Filler, Bone Void, C Filler, Bone Void, Osteoinduction (W/O Human Growth Factor),Filler, Bone Void, Calcium Compound | 2 | DBM Putty 0.5cc | |
44 | 00849777008778 | 27800418 | ONE (1) PACKAGE - CONTAINING 5.0cc | MQV,MBP | Filler, Bone Void, Calcium Compound,Filler, Bone Void, Osteoinduction (W/O Human Filler, Bone Void, Calcium Compound,Filler, Bone Void, Osteoinduction (W/O Human Growth Factor) | 2 | Reficio DBM Putty 5cc | |
45 | 00849777008761 | 27800218 | ONE (1) PACKAGE - CONTAINING 1.0cc | MQV,MBP | Filler, Bone Void, Calcium Compound,Filler, Bone Void, Osteoinduction (W/O Human Filler, Bone Void, Calcium Compound,Filler, Bone Void, Osteoinduction (W/O Human Growth Factor) | 2 | Reficio DBM Putty 1cc | |
46 | 00849777008532 | DU-25PS | ONE (1) PACKAGE - CONTAINING 2.5cc | MBP,MQV | Filler, Bone Void, Osteoinduction (W/O Human Growth Factor),Filler, Bone Void, C Filler, Bone Void, Osteoinduction (W/O Human Growth Factor),Filler, Bone Void, Calcium Compound | 2 | DBM Putty 2.5cc Syringe | |
47 | 00849777008372 | X090-0015-PT0.5CCJ | ONE (1) PACKAGE - CONTAINING 0.5cc | MBP,MQV | Filler, Bone Void, Osteoinduction (W/O Human Growth Factor),Filler, Bone Void, C Filler, Bone Void, Osteoinduction (W/O Human Growth Factor),Filler, Bone Void, Calcium Compound | 2 | Axograft DBM Putty 0.5cc - Jar | |
48 | 00849777008136 | BXS-600-025-M | ONE (1) PACKAGE - CONTAINING 2.5cc | MQV,MBP | Filler, Bone Void, Calcium Compound,Filler, Bone Void, Osteoinduction (W/O Human Filler, Bone Void, Calcium Compound,Filler, Bone Void, Osteoinduction (W/O Human Growth Factor) | 2 | DBM Putty 2.5cc in a Syringe | |
49 | 00849777007733 | NUX-02P | ONE (1) PACKAGE - CONTAINING 2.5cc | MQV,MBP | Filler, Bone Void, Calcium Compound,Filler, Bone Void, Osteoinduction (W/O Human Filler, Bone Void, Calcium Compound,Filler, Bone Void, Osteoinduction (W/O Human Growth Factor) | 2 | DBM Putty 2.5cc in a Syringe | |
50 | 00849777007474 | XT-309025 | 2.5cc | MQV,MBP | Filler, Bone Void, Calcium Compound,Filler, Bone Void, Osteoinduction (W/O Human Filler, Bone Void, Calcium Compound,Filler, Bone Void, Osteoinduction (W/O Human Growth Factor) | 2 | KBM STERILE PUTTY |
No | Primary DI | Version or Model | Catalog Number | Device Description | Brand Name | Organization Name |
---|---|---|---|---|---|---|
1 | 08033390167574 | 9084.20.087 | 9084.20.087 | Dia. 3,2 mm Helix Drill | SMR Shoulder | LIMACORPORATE SPA |
2 | 08033390127066 | 9CC0.30.030 | 9CC0.30.030 | Drill Bit - Dia. 4,5 mm L. 120 mm | SMR Shoulder | LIMACORPORATE SPA |
3 | 08033390119412 | 9013.79.216 | 9013.79.216 | Quick Connection Drill Dia. 5 mm - SMR Shoulder | SMR Shoulder system | LIMACORPORATE SPA |
4 | 08033390118354 | 9084.20.084 | 9084.20.084 | Dia. 4 mm, L 40 mm Helix Drill | SMR Shoulder system | LIMACORPORATE SPA |
5 | 08033390114332 | 9013.79.211 | 9013.79.211 | Cannulated Drill Dia. 5 mm | SMR Shoulder system | LIMACORPORATE SPA |
6 | 08033390107587 | 9CCA.13.002 | 9CCA.13.002 | Drill Dia. 5 mm, L. 190 mm | SMR Shoulder system | LIMACORPORATE SPA |
7 | 08033390106009 | 9C66.40.061 | 9C66.40.061 | Cannullated drill Dia. 5 mm | SMR Shoulder system | LIMACORPORATE SPA |
8 | 08033390099684 | 9084.20.086 | 9084.20.086 | Long Helix Drill Dia 3.5 mm, L. 79 mm | SMR Shoulder system | LIMACORPORATE SPA |
9 | 08033390099677 | 9084.20.081 | 9084.20.081 | Helix Drill Dia. 3.5 mm | SMR Shoulder system | LIMACORPORATE SPA |
10 | 08032909620517 | Drill ø5/7.5 mm Jacobs joint | 50166 | Orthopaedic Surgical Instruments | CITIEFFE SRL | |
11 | 08032909620333 | Cannulated drill bit ø6.5mm Jacobs joint | 50169 | Orthopaedic Surgical Instruments | CITIEFFE SRL | |
12 | 07708626670999 | 0 | /BARC2.8-W3 | Drill 2 mm | SAMPEDRO | INDUSTRIAS MEDICAS SAMPEDRO S A S |
13 | 07708626670876 | 0 | /BGC2.8AT | Short Drill Bit Ø 2,8mm | SAMPEDRO | INDUSTRIAS MEDICAS SAMPEDRO S A S |
14 | 07708626670746 | 0 | /BAR35195 | Drill Bit Ø 3.5mm X 195mm | SAMPEDRO | INDUSTRIAS MEDICAS SAMPEDRO S A S |
15 | 07708626670715 | 0 | /B25195 | Drill Bit φ2.5 | SAMPEDRO | INDUSTRIAS MEDICAS SAMPEDRO S A S |
16 | 07708626670524 | 0 | /BAR2516 | Drill bit Ø 2.5mm X 160/135mm | SAMPEDRO | INDUSTRIAS MEDICAS SAMPEDRO S A S |
17 | 07708626670500 | 0 | /BGL2.8AT | Long Drill Bit Ø 2,8mm | SAMPEDRO | INDUSTRIAS MEDICAS SAMPEDRO S A S |
18 | 07708604560878 | 0 | /FC20AO | Cannulated drill 2.0MM AO | SAMPEDRO | INDUSTRIAS MEDICAS SAMPEDRO S A S |
19 | 07708604560847 | 0 | /BAR2.0M-W | Drill Bit 2 mm x 100/75mm, AO | SAMPEDRO | INDUSTRIAS MEDICAS SAMPEDRO S A S |
20 | 07708604560809 | 0 | /GBB20E-W | Locking drill guide 2.0 with measuring scale | SAMPEDRO | INDUSTRIAS MEDICAS SAMPEDRO S A S |
21 | 07708604560441 | 0 | /BAR20125 | Drill bit 2 mm x 125/100mm, AO | SAMPEDRO | INDUSTRIAS MEDICAS SAMPEDRO S A S |
22 | 07708604560328 | 0 | /BAR25147 | Drill Bit 2.5 Mm, AO Quick Couplin | SAMPEDRO | INDUSTRIAS MEDICAS SAMPEDRO S A S |
23 | 07708604560311 | 0 | /BAR2516 | Drill Bit 2,5 mm x 160/135mm | SAMPEDRO | INDUSTRIAS MEDICAS SAMPEDRO S A S |
24 | 07708604560298 | 0 | /B20-W3 | Drill 2 mm | SAMPEDRO | INDUSTRIAS MEDICAS SAMPEDRO S A S |
25 | 07708604560090 | 0 | /BARC20125 | Drill bit 2 mm x 125/100mm, AO | SAMPEDRO | INDUSTRIAS MEDICAS SAMPEDRO S A S |
26 | 07640450863157 | SPE-US 00 73-N | SPE-US 00 73-N | ANGLED TRIAL R-SIDE APPROACH 21MM H14 LORDOSIS 8° | JULIET ® LL | SPINEART SA |
27 | 07640450863140 | SPE-US 00 72-N | SPE-US 00 72-N | ANGLED TRIAL R-SIDE APPROACH 21MM H12 LORDOSIS 8° | JULIET ® LL | SPINEART SA |
28 | 07640450863133 | SPE-US 00 71-N | SPE-US 00 71-N | ANGLED TRIAL R-SIDE APPROACH 21MM H10 LORDOSIS 8° | JULIET ® LL | SPINEART SA |
29 | 07640450863126 | SPE-US 00 70-N | SPE-US 00 70-N | ANGLED TRIAL R-SIDE APPROACH 21MM H08 LORDOSIS 8° | JULIET ® LL | SPINEART SA |
30 | 07640450863119 | SPE-US 00 69-N | SPE-US 00 69-N | ANGLED TRIAL R-SIDE APPROACH 17MM H14 LORDOSIS 8 | JULIET ® LL | SPINEART SA |
31 | 07640450863102 | SPE-US 00 68-N | SPE-US 00 68-N | ANGLED TRIAL R-SIDE APPROACH 17MM H12 LORDOSIS 8° | JULIET ® LL | SPINEART SA |
32 | 07640450863096 | SPE-US 00 67-N | SPE-US 00 67-N | ANGLED TRIAL R-SIDE APPROACH 17MM H10 LORDOSIS 8 | JULIET ® LL | SPINEART SA |
33 | 07640450863089 | SPE-US 00 66-N | SPE-US 00 66-N | ANGLED TRIAL R-SIDE APPROACH 17MM H08 LORDOSIS 8° | JULIET ® LL | SPINEART SA |
34 | 07640187914184 | T882 | T882 | The drills with or without coupling for attachment to a power tool are re-usable The drills with or without coupling for attachment to a power tool are re-usable rotary cutting instruments used in surgery for drilling cylindrical holes into bone. The cutting action is determined by the cutting edges.Two kind of coupling, permitting the connection with the power tool, exist: an AO coupling or a chuck coupling. A range of diameter and length is proposed.The drills are used with a power tool. | Drill little AO coupling Ø3 x 146 mm | MPS PRECIMED SA |
35 | 07640187913965 | T2314 | T2314 | The drills with a transversal pin, permitting the transmission of the torque, ar The drills with a transversal pin, permitting the transmission of the torque, are re-usable rotary cutting instruments used in surgery for drilling cylindrical holes into bone. The cutting action is determined by the cutting edges. A range of diameter and length is proposed.The drills are used with a power tool. | Bayonet drill Ø3.2 x 42 mm | MPS PRECIMED SA |
36 | 07640187913958 | T2313 | T2313 | The drills with a transversal pin, permitting the transmission of the torque, ar The drills with a transversal pin, permitting the transmission of the torque, are re-usable rotary cutting instruments used in surgery for drilling cylindrical holes into bone. The cutting action is determined by the cutting edges. A range of diameter and length is proposed.The drills are used with a power tool. | Bayonet drill Ø3.2 x 62 mm | MPS PRECIMED SA |
37 | 07640187913941 | T2288 | T2288 | The drills with a transversal pin, permitting the transmission of the torque, ar The drills with a transversal pin, permitting the transmission of the torque, are re-usable rotary cutting instruments used in surgery for drilling cylindrical holes into bone. The cutting action is determined by the cutting edges. A range of diameter and length is proposed.The drills are used with a power tool. | Bayonet drill Ø3.2 x 52 mm | MPS PRECIMED SA |
38 | 07640187913934 | T2287 | T2287 | The drills with a transversal pin, permitting the transmission of the torque, ar The drills with a transversal pin, permitting the transmission of the torque, are re-usable rotary cutting instruments used in surgery for drilling cylindrical holes into bone. The cutting action is determined by the cutting edges. A range of diameter and length is proposed.The drills are used with a power tool. | Bayonet drill Ø4.5 x 62 mm | MPS PRECIMED SA |
39 | 07640187913927 | T2284 | T2284 | The drills with a transversal pin, permitting the transmission of the torque, ar The drills with a transversal pin, permitting the transmission of the torque, are re-usable rotary cutting instruments used in surgery for drilling cylindrical holes into bone. The cutting action is determined by the cutting edges. A range of diameter and length is proposed.The drills are used with a power tool. | Bayonet drill Ø4.5 x 70 mm | MPS PRECIMED SA |
40 | 07640187913910 | T2282 | T2282 | The drills with a transversal pin, permitting the transmission of the torque, ar The drills with a transversal pin, permitting the transmission of the torque, are re-usable rotary cutting instruments used in surgery for drilling cylindrical holes into bone. The cutting action is determined by the cutting edges. A range of diameter and length is proposed.The drills are used with a power tool. | Bayonet drill Ø4.5 x 50 mm | MPS PRECIMED SA |
41 | 07640187913903 | T1926 | T1926 | The drills with a transversal pin, permitting the transmission of the torque, ar The drills with a transversal pin, permitting the transmission of the torque, are re-usable rotary cutting instruments used in surgery for drilling cylindrical holes into bone. The cutting action is determined by the cutting edges. A range of diameter and length is proposed.The drills are used with a power tool. | Bayonet drill Ø4.5 x 42 mm | MPS PRECIMED SA |
42 | 07640187913897 | T1262 | T1262 | The drills with a transversal pin, permitting the transmission of the torque, ar The drills with a transversal pin, permitting the transmission of the torque, are re-usable rotary cutting instruments used in surgery for drilling cylindrical holes into bone. The cutting action is determined by the cutting edges. A range of diameter and length is proposed.The drills are used with a power tool. | Bayonet drill Ø4.5 x 70 mm | MPS PRECIMED SA |
43 | 07640187913873 | T3313 | T3313 | The drills with a transversal pin, permitting the transmission of the torque, ar The drills with a transversal pin, permitting the transmission of the torque, are re-usable rotary cutting instruments used in surgery for drilling cylindrical holes into bone. The cutting action is determined by the cutting edges. A range of diameter and length is proposed.The drills are used with a power tool. | Bayonet drill Ø4.5 x 56 mm | MPS PRECIMED SA |
44 | 07640187913866 | T2754 | T2754 | The drills with a transversal pin, permitting the transmission of the torque, ar The drills with a transversal pin, permitting the transmission of the torque, are re-usable rotary cutting instruments used in surgery for drilling cylindrical holes into bone. The cutting action is determined by the cutting edges. A range of diameter and length is proposed.The drills are used with a power tool. | Bayonet drill Ø4.5 x 50 mm | MPS PRECIMED SA |
45 | 07640187913804 | T718 | T718 | The drills with a transversal pin, permitting the transmission of the torque, ar The drills with a transversal pin, permitting the transmission of the torque, are re-usable rotary cutting instruments used in surgery for drilling cylindrical holes into bone. The cutting action is determined by the cutting edges. A range of diameter and length is proposed.The drills are used with a power tool. | Bayonet drill Ø3.5 x 50 mm | MPS PRECIMED SA |
46 | 07640187913781 | T717 | T717 | The drills with a transversal pin, permitting the transmission of the torque, ar The drills with a transversal pin, permitting the transmission of the torque, are re-usable rotary cutting instruments used in surgery for drilling cylindrical holes into bone. The cutting action is determined by the cutting edges. A range of diameter and length is proposed.The drills are used with a power tool. | Bayonet drill Ø3.2 x 70 mm | MPS PRECIMED SA |
47 | 07640187913750 | T6029 | T6029 | The drills with a transversal pin, permitting the transmission of the torque, ar The drills with a transversal pin, permitting the transmission of the torque, are re-usable rotary cutting instruments used in surgery for drilling cylindrical holes into bone. The cutting action is determined by the cutting edges. A range of diameter and length is proposed.The drills are used with a power tool. | Bayonet drill Ø3.2 x 59 mm | MPS PRECIMED SA |
48 | 07640187913743 | T830 | T830 | The drills with a transversal pin, permitting the transmission of the torque, ar The drills with a transversal pin, permitting the transmission of the torque, are re-usable rotary cutting instruments used in surgery for drilling cylindrical holes into bone. The cutting action is determined by the cutting edges. A range of diameter and length is proposed.The drills are used with a power tool. | Bayonet drill Ø3.2 x 56 mm | MPS PRECIMED SA |
49 | 07640187913705 | T6028 | T6028 | The drills with a transversal pin, permitting the transmission of the torque, ar The drills with a transversal pin, permitting the transmission of the torque, are re-usable rotary cutting instruments used in surgery for drilling cylindrical holes into bone. The cutting action is determined by the cutting edges. A range of diameter and length is proposed.The drills are used with a power tool. | Bayonet drill Ø3.2 x 40 mm | MPS PRECIMED SA |
50 | 07640187910926 | T1276 | T1276 | The drills with a transversal pin, permitting the transmission of the torque, ar The drills with a transversal pin, permitting the transmission of the torque, are re-usable rotary cutting instruments used in surgery for drilling cylindrical holes into bone. The cutting action is determined by the cutting edges. A range of diameter and length is proposed.The drills are used with a power tool. | Bayonet drill Ø3.2 x 35 mm | MPS PRECIMED SA |