Other products from "ORTHOPAEDIC IMPLANT COMPANY, THE"
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 M696PS5565400 PS5.5-6.5-40 PEDICLE SCREW, POLYAXIAL, 6.5MM X 40MM MNI Orthosis, Spinal Pedicle Fixation 2 OIC Pedicle Screw System
2 M696CPS620S0 CPS-620S CERVICAL CAGE INSERTER ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 C-PS Peek Optima Cervical Interbody Spacer
3 M696CPS610S0 CPS-610S CERVICAL CAGE SIZER 10MM X 15MM ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 C-PS Peek Optima Cervical Interbody Spacer
4 M696CPS609S0 CPS-609S CERVICAL CAGE SIZER 9MM X 15MM ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 C-PS Peek Optima Cervical Interbody Spacer
5 M696CPS608S0 CPS-608S CERVICAL CAGE SIZER 8MM X 15MM ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 C-PS Peek Optima Cervical Interbody Spacer
6 M696CPS607S0 CPS-607S CERVICAL CAGE SIZER 7MM X 15MM ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 C-PS Peek Optima Cervical Interbody Spacer
7 M696CPS606S0 CPS-606S CERVICAL CAGE SIZER 6MM X 15MM ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 C-PS Peek Optima Cervical Interbody Spacer
8 M696CPS605S0 CPS-605S CERVICAL CAGE SIZER 10MM X 12MM ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 C-PS Peek Optima Cervical Interbody Spacer
9 M696CPS604S0 CPS-604S CERVICAL CAGE SIZER 9MM X 12MM ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 C-PS Peek Optima Cervical Interbody Spacer
10 M696CPS603S0 CPS-603S CERVICAL CAGE SIZER 8MM X 12MM ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 C-PS Peek Optima Cervical Interbody Spacer
11 M696CPS602S0 CPS-602S CERVICAL CAGE SIZER 7MM X 12MM ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 C-PS Peek Optima Cervical Interbody Spacer
12 M696CPS601S0 CPS-601S CERVICAL CAGE SIZER 6MM X 12MM ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 C-PS Peek Optima Cervical Interbody Spacer
13 M696CPS600S0 CPS-600S STERILIZATION CASE CERVICAL CAGE SET ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 C-PS Peek Optima Cervical Interbody Spacer
14 M696CPS1015S0 CPS-1015S PEEK CERVICAL CAGE 10MM X 15MM ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 C-PS Peek Optima Cervical Interbody Spacer
15 M696CPS1012S0 CPS-1012S PEEK CERVICAL CAGE 10MM X 12MM ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 C-PS Peek Optima Cervical Interbody Spacer
16 M696CPS0915S0 CPS-0915S PEEK CERVICAL CAGE 9MM X 15MM ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 C-PS Peek Optima Cervical Interbody Spacer
17 M696CPS0912S0 CPS-0912S PEEK CERVICAL CAGE 9MM X 12MM ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 C-PS Peek Optima Cervical Interbody Spacer
18 M696CPS0815S0 CPS-0815S PEEK CERVICAL CAGE 8MM X 15MM ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 C-PS Peek Optima Cervical Interbody Spacer
19 M696CPS0812S0 CPS-0812S PEEK CERVICAL CAGE 8MM X 12MM ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 C-PS Peek Optima Cervical Interbody Spacer
20 M696CPS0715S0 CPS-0715S PEEK CERVICAL CAGE 7MM X 15MM ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 C-PS Peek Optima Cervical Interbody Spacer
21 M696CPS0712S0 CPS-0712S PEEK CERVICAL CAGE 7MM X 12MM ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 C-PS Peek Optima Cervical Interbody Spacer
22 M696CPS0615S0 CPS-0615S PEEK CERVICAL CAGE 6MM X 15MM ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 C-PS Peek Optima Cervical Interbody Spacer
23 M696CPS0612S0 CPS-0612S PEEK CERVICAL CAGE 6MM X 12MM ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 C-PS Peek Optima Cervical Interbody Spacer
24 M69601CPS020 01-CPS02 STERILIZATION CASE CERVICAL SPACER COMPLETE ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 C-PS Peek Optima Cervical Interbody Spacer
25 M69601CPS010 01-CPS01 STERILIZATION CASE CERVICAL SPACER INNER ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 C-PS Peek Optima Cervical Interbody Spacer
26 10811998034871 PHP-05124R PROXIMAL HUMERUS PLATE 5 HOLE RIGHT HRS Plate, Fixation, Bone 2 OIC Variable Angle Small Fragment Locking Plate System
27 10811998034864 PHP-05124L PROXIMAL HUMERUS PLATE 5 HOLE LEFT HRS Plate, Fixation, Bone 2 OIC Variable Angle Small Fragment Locking Plate System
28 10811998034857 PHP-03100R PROXIMAL HUMERUS PLATE 3 HOLE RIGHT HRS Plate, Fixation, Bone 2 OIC Variable Angle Small Fragment Locking Plate System
29 10811998034840 PHP-03100L PROXIMAL HUMERUS PLATE 3 HOLE LEFT HRS Plate, Fixation, Bone 2 OIC Variable Angle Small Fragment Locking Plate System
30 10811998034833 MDT-16252R MEDIAL DISTAL TIBIA PLATE 16 HOLE RIGHT HRS Plate, Fixation, Bone 2 OIC Variable Angle Small Fragment Locking Plate System
31 10811998034826 MDT-16252L MEDIAL DISTAL TIBIA PLATE 16 HOLE LEFT HRS Plate, Fixation, Bone 2 OIC Variable Angle Small Fragment Locking Plate System
32 10811998034819 MDT-13214R MEDIAL DISTAL TIBIA PLATE 13 HOLE RIGHT HRS Plate, Fixation, Bone 2 OIC Variable Angle Small Fragment Locking Plate System
33 10811998034802 MDT-13214L MEDIAL DISTAL TIBIA PLATE 13 HOLE LEFT HRS Plate, Fixation, Bone 2 OIC Variable Angle Small Fragment Locking Plate System
34 10811998034796 MDT-10177R MEDIAL DISTAL TIBIA PLATE 10 HOLE RIGHT HRS Plate, Fixation, Bone 2 OIC Variable Angle Small Fragment Locking Plate System
35 10811998034789 MDT-10177L MEDIAL DISTAL TIBIA PLATE 10 HOLE LEFT HRS Plate, Fixation, Bone 2 OIC Variable Angle Small Fragment Locking Plate System
36 10811998034772 MDT-08152R MEDIAL DISTAL TIBIA PLATE 8 HOLE RIGHT HRS Plate, Fixation, Bone 2 OIC Variable Angle Small Fragment Locking Plate System
37 10811998034765 MDT-08152L MEDIAL DISTAL TIBIA PLATE 8 HOLE LEFT HRS Plate, Fixation, Bone 2 OIC Variable Angle Small Fragment Locking Plate System
38 10811998034758 MDT-06127R MEDIAL DISTAL TIBIA PLATE 6 HOLE RIGHT HRS Plate, Fixation, Bone 2 OIC Variable Angle Small Fragment Locking Plate System
39 10811998034741 MDT-06127L MEDIAL DISTAL TIBIA PLATE 6 HOLE LEFT HRS Plate, Fixation, Bone 2 OIC Variable Angle Small Fragment Locking Plate System
40 10811998034734 MDT-03089R MEDIAL DISTAL TIBIA PLATE 3 HOLE RIGHT HRS Plate, Fixation, Bone 2 OIC Variable Angle Small Fragment Locking Plate System
41 10811998034727 MDT-03089L MEDIAL DISTAL TIBIA PLATE 3 HOLE LEFT HRS Plate, Fixation, Bone 2 OIC Variable Angle Small Fragment Locking Plate System
42 10811998034710 LS-3585 3.5MM X 85MM LOCKING SCREW HWC Screw, Fixation, Bone 2 OIC Variable Angle Small Fragment Locking Plate System
43 10811998034703 LS-3580 3.5MM X 80MM LOCKING SCREW HWC Screw, Fixation, Bone 2 OIC Variable Angle Small Fragment Locking Plate System
44 10811998034697 LS-3575 3.5MM X 75MM LOCKING SCREW HWC Screw, Fixation, Bone 2 OIC Variable Angle Small Fragment Locking Plate System
45 10811998034680 LS-3570 3.5MM X 70MM LOCKING SCREW HWC Screw, Fixation, Bone 2 OIC Variable Angle Small Fragment Locking Plate System
46 10811998034673 LS-3565 3.5MM X 65MM LOCKING SCREW HWC Screw, Fixation, Bone 2 OIC Variable Angle Small Fragment Locking Plate System
47 10811998034666 LS-3560 3.5MM X 60MM LOCKING SCREW HWC Screw, Fixation, Bone 2 OIC Variable Angle Small Fragment Locking Plate System
48 10811998034659 LS-3555 3.5MM X 55MM LOCKING SCREW HWC Screw, Fixation, Bone 2 OIC Variable Angle Small Fragment Locking Plate System
49 10811998034642 LS-3550 3.5MM X 50MM LOCKING SCREW HWC Screw, Fixation, Bone 2 OIC Variable Angle Small Fragment Locking Plate System
50 10811998034635 LS-3545 3.5MM X 45MM LOCKING SCREW HWC Screw, Fixation, Bone 2 OIC Variable Angle Small Fragment Locking Plate System
Other products with the same Product Code "HRS"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 M621OW30LBS26MM0 GM-500-26 OW3.0LBS-26MM osteo-WEDGE 3.0mm x 26mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 3.0mm x 26mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE 3.0mm x 26mm Locking Bone Screw GRAMEDICA
2 M621OW30LBS24MM0 GM-500-24 OW3.0LBS-24MM osteo-WEDGE 3.0mm x 24mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 3.0mm x 24mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE 3.0mm x 24mm Locking Bone Screw GRAMEDICA
3 M621OW30LBS22MM0 GM-500-22 OW3.0LBS-22MM osteo-WEDGE 3.0mm x 22mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 3.0mm x 22mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE 3.0mm x 22mm Locking Bone Screw GRAMEDICA
4 M621OW30LBS20MM0 GM-500-20 OW3.0LBS-20MM osteo-WEDGE 3.0mm x 20mm Locking Bone Screw. For use with the osteo-WEDGE Openi osteo-WEDGE 3.0mm x 20mm Locking Bone Screw. For use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE 3.0mm x 20mm Locking Bone Screw GRAMEDICA
5 M621OW30LBS18MM0 GM-500-18 OW3.0LBS-18MM osteo-WEDGE 3.0mm x 18mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 3.0mm x 18mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE 3.0mm x 18mm Locking Bone Screw GRAMEDICA
6 M621OW30LBS16MM0 GM-500-16 OW3.0LBS-16MM osteo-WEDGE 3.0mm x 16mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 3.0mm x 16mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE 3.0mm x 16mm Locking Bone Screw GRAMEDICA
7 M621OW30LBS14MM0 GM-500-14 OW3.0LBS-14MM osteo-WEDGE 3.0mm x 14mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 3.0mm x 14mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE 3.0mm x 14mm Locking Bone Screw GRAMEDICA
8 M621OW30LBS12MM0 GM-500-12 OW3.0LBS-12MM osteo-WEDGE 3.0mm x 12mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 3.0mm x 12mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE 3.0mm x 12mm Locking Bone Screw GRAMEDICA
9 M621OW30LBS10MM0 GM-500-10 OW3.0LBS-10MM osteo-WEDGE 3.0mm x 10mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 3.0mm x 10mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE 3.0mm x 10mm Locking Bone Screw GRAMEDICA
10 M621OW30LBS08MM0 GM-500-08 OW3.0LBS-08MM osteo-WEDGE 3.0mm x 08mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 3.0mm x 08mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE 3.0mm x 08mm Locking Bone Screw GRAMEDICA
11 M621OW25LBS22MM0 GM-200-22 OW2.5LBS-22MM osteo-WEDGE 2.5mm x 22mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 2.5mm x 22mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE 2.5mm x 22mm Locking Bone Screw GRAMEDICA
12 M621OW25LBS18MM0 GM-200-18 OW2.5LBS-18MM osteo-WEDGE 2.5mm x 18mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 2.5mm x 18mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE 2.5mm x 18mm Locking Bone Screw GRAMEDICA
13 M621OW25LBS16MM0 GM-200-16 OW2.5LBS-16MM osteo-WEDGE 2.5mm x 16mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 2.5mm x 16mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE 2.5mm x 16mm Locking Bone Screw GRAMEDICA
14 M621OW25LBS14MM0 GM-200-14 OW2.5LBS-14MM osteo-WEDGE 2.5mm x 14mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 2.5mm x 14mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE 2.5mm x 14mm Locking Bone Screw GRAMEDICA
15 M621OW25LBS12MM0 GM-200-12 OW2.5LBS-12MM osteo-WEDGE 2.5mm x 12mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 2.5mm x 12mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE 2.5mm x 12mm Locking Bone Screw GRAMEDICA
16 M621OW25LBS10MM0 GM-200-10 OW2.5LBS-10MM osteo-WEDGE 2.5mm x 10mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 2.5mm x 10mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE 2.5mm x 10mm Locking Bone Screw GRAMEDICA
17 M621OW25LBS08MM0 GM-200-08 OW2.5LBS-08MM osteo-WEDGE 2.5mm x 08mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 2.5mm x 08mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE 2.5mm x 08mm Locking Bone Screw GRAMEDICA
18 M621OW24TT12MM0 GM-100-12 OW2.4TT-12MM osteo-WEDGE Temporary Tack, 2.4mm x 12mm. Non-sterile single use (disposable) a osteo-WEDGE Temporary Tack, 2.4mm x 12mm. Non-sterile single use (disposable) accessory for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE Temporary Tack 2.4mm x 12mm GRAMEDICA
19 M621GM504300 GM-504-30 GM-504-30 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 30 Degree Angulated Bone Plate Implant, Large GRAMEDICA
20 M621GM504270 GM-504-27 GM-504-27 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 27 Degree Angulated Bone Plate Implant, Large GRAMEDICA
21 M621GM504240 GM-504-24 GM-504-24 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 24 Degree Angulated Bone Plate Implant, Large GRAMEDICA
22 M621GM504210 GM-504-21 GM-504-21 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 21 Degree Angulated Bone Plate Implant, Large GRAMEDICA
23 M621GM504180 GM-504-18 GM-504-18 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 18 Degree Angulated Bone Plate Implant, Large GRAMEDICA
24 M621GM504150 GM-504-15 GM-504-15 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 15 Degree Angulated Bone Plate Implant, Large GRAMEDICA
25 M621GM504120 GM-504-12 GM-504-12 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 12 Degree Angulated Bone Plate Implant, Large GRAMEDICA
26 M621GM504090 GM-504-09 GM-504-09 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 9 Degree Angulated Bone Plate Implant, Large GRAMEDICA
27 M621GM504060 GM-504-06 GM-504-06 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 6 Degree Angulated Bone Plate Implant, Large GRAMEDICA
28 M621GM504030 GM-504-03 GM-504-03 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 3 Degree Angulated Bone Plate Implant, Large GRAMEDICA
29 M621GM503300 GM-503-30 GM-503-30 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 30 Degree Angulated Bone Plate Implant, Small GRAMEDICA
30 M621GM503270 GM-503-27 GM-503-27 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 27 Degree Angulated Bone Plate Implant, Small GRAMEDICA
31 M621GM503240 GM-503-24 GM-503-24 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 24 Degree Angulated Bone Plate Implant, Small GRAMEDICA
32 M621GM503210 GM-503-21 GM-503-21 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 21 Degree Angulated Bone Plate Implant, Small GRAMEDICA
33 M621GM503180 GM-503-18 GM-503-18 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 18 Degree Angulated Bone Plate Implant-Small GRAMEDICA
34 M621GM503150 GM-503-15 GM-503-15 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 15 Degree Angulated Bone Plate Implant, Small GRAMEDICA
35 M621GM503120 GM-503-12 GM-503-12 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 12 Degree Angulated Bone Plate Implant, Small GRAMEDICA
36 M621GM503090 GM-503-09 GM-503-09 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 9 Degree Angulated Bone Plate Implant, Small GRAMEDICA
37 M621GM503060 GM-503-06 GM-503-06 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 6 Degree Angulated Bone Plate Implant, Small GRAMEDICA
38 M621GM503030 GM-503-03 GM-503-03 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 3 Degree Angulated Bone Plate Implant, Small GRAMEDICA
39 M621GM503000 GM-503-00 GM-503-00 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 0 Degree, Flat Bone Plate Implant, Small GRAMEDICA
40 M621GM501100 GM-501-10 GM-501-10 osteo-WEDGE Bone Plate 10mm. Non-sterile single use implant for use with the ost osteo-WEDGE Bone Plate 10mm. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE Bone Plate 10mm GRAMEDICA
41 M621GM501080 GM-501-08 GM-501-08 osteo-WEDGE Bone Plate 08mm. Non-sterile single use implant for use with the os osteo-WEDGE Bone Plate 08mm. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE Bone Plate 08mm GRAMEDICA
42 M621GM501060 GM-501-06 GM-501-06 osteo-WEDGE Bone Plate 06mm. Non-sterile single use implant for use with the os osteo-WEDGE Bone Plate 06mm. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE Bone Plate 06mm GRAMEDICA
43 M621GM501040 GM-501-04 GM-501-04 osteo-WEDGE Bone Plate 04mm. Non-sterile single use implant for use with the os osteo-WEDGE Bone Plate 04mm. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE Bone Plate 04mm GRAMEDICA
44 M621GM501020 GM-501-02 GM-501-02 osteo-WEDGE Bone Plate 02mm. Non-sterile single use implant for use with the os osteo-WEDGE Bone Plate 02mm. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE Bone Plate 02mm GRAMEDICA
45 M621GM501000 GM-501-00 GM-501-00 osteo-WEDGE Bone Plate 00mm. Non-sterile single use implant for use with the os osteo-WEDGE Bone Plate 00mm. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE Bone Plate 00mm GRAMEDICA
46 M621GM160040 GM-160-04 GM-160-04 osteo-WEDGE2 Drill Guide, a reusable instrument, for use with the osteo-WEDGE O osteo-WEDGE2 Drill Guide, a reusable instrument, for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 Drill Guide GRAMEDICA
47 M621GM160030 GM-160-03 GM-160-03 osteo-WEDGE2 Drill Guide, a reusable instrument, for use with the osteo-WEDGE O osteo-WEDGE2 Drill Guide, a reusable instrument, for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 Drill Guide GRAMEDICA
48 M621GM160010 GM-160-01 GM-160-01 osteo-WEDGE Drill Guide, a reusable instrument, for use with the osteo-WEDGE Op osteo-WEDGE Drill Guide, a reusable instrument, for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE Drill Guide GRAMEDICA
49 M621GM150040 GM-150-04 GM-150-04 osteo-WEDGE Screw Retainer Sleeve, a reusable instrument, for use with the oste osteo-WEDGE Screw Retainer Sleeve, a reusable instrument, for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE Screw Retainer Sleeve GRAMEDICA
50 M621GM150030 GM-150-03 GM-150-03 osteo-WEDGE Driver, a reusable instrument, for use with the osteo-WEDGE Opening osteo-WEDGE Driver, a reusable instrument, for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE Driver GRAMEDICA