Software, TomoApps, Version 5.1.2Operating Software for TomoTherapy systems (inc
Software, TomoApps, Version 5.1.2Operating Software for TomoTherapy systems (including TomoH®, TomoHD®, TomoHDA) and Onrad Treatment System™
CyberKnife® M6™ Series (including configurations: M6 Neuro, M6 FI, M6 FIM, & M6
CyberKnife® M6™ Series (including configurations: M6 Neuro, M6 FI, M6 FIM, & M6 FM)The CyberKnife M6 Systems are computer-controlled medical systems for planning and performing minimally invasive stereotactic radiosurgery and precision radiotherapy. They use a 6 MV linear accelerator mounted on a manipulator (robot) and a target locating subsystem to accurately deliver high-energy radiation (1000 MU/minute dose rate) to the treatment target. The target locating subsystem provides X-rays of the treatment area that lets the user know the position of the target.The CyberKnife M6 Systems use skull tracking, fiducial tracking (tracking of implanted radiographic markers), skeletal structure tracking, lung tumor tracking, Lung Optimized Treatment, and Synchrony Respiratory Tracking for dynamic positioning and pointing of the linear accelerator. The fixed, variable aperture and multileaf collimators are available as various beam-limiting secondary collimators.
Software, Version 1.1.1, Accuray Precision Treatment Planning SystemThe Accuray
Software, Version 1.1.1, Accuray Precision Treatment Planning SystemThe Accuray Precision Treatment Planning System is a radiation therapy planning system used for creation and assessment of treatment plans for delivery by radiation therapy, stereotactic radiotherapy or stereotactic radiosurgery treatment systems.
Software, Version 1.0.0.1, Accuray Precision Treatment Planning System, The Accu
Software, Version 1.0.0.1, Accuray Precision Treatment Planning System, The Accuray Precision Treatment Planning System is a radiation therapy planning system used for creation and assessment of treatment plans for delivery by radiation therapy, stereotactic radiotherapy or stereotactic radiosurgery treatment systems.
Software, Version 1.0, Precision Treatment Planning SystemThe Accuray Precision
Software, Version 1.0, Precision Treatment Planning SystemThe Accuray Precision Treatment Planning System is indicated for creation and assessment of external photon beam irradiation treatment plans for radiation therapy, stereotactic radiotherapy or stereotactic radiosurgery for lesions, tumors and conditions anywhere in the body when radiation treatment is indicated. A treatment plan provides an estimate of the dose distribution and the parameters utilized by the radiation delivery system. Plans must be reviewed and approved by qualified medical practitioners prior to delivery.
Software, Version 2.0, Accuray Precision Treatment Planning SystemThe Accuray Pr
Software, Version 2.0, Accuray Precision Treatment Planning SystemThe Accuray Precision Treatment Planning System is a radiation therapy planning system used for creation and assessment of treatment plans for delivery by radiation therapy, stereotactic radiotherapy or stereotactic radiosurgery treatment systems.
Software, TomoApps, Version 5.1.3Operating Software for TomoTherapy systems (inc
Software, TomoApps, Version 5.1.3Operating Software for TomoTherapy systems (including TomoH, TomoHD, TomoHDA) and Onrad Treatment System.
Software, Accuray Precision Treatment Planning System, (Version 1.1.1.1)The Accu
Software, Accuray Precision Treatment Planning System, (Version 1.1.1.1)The Accuray Precision Treatment Planning System is a radiation therapy planning system used for creation and assessment of treatment plans for delivery by radiation therapy, stereotactic radiotherapy or stereotactic radiosurgery treatment systems.
MUJ,IYE
System,Planning,Radiation Therapy Treatment,Accelerator, Linear, Medical
The CyberKnife VSI System is a computer controlled medical systems for planning
The CyberKnife VSI System is a computer controlled medical systems for planning and performing minimally invasive stereotactic radiosurgery and precision radiotherapy using a treatment radiation generator, linear accelerator, manipulator (robot), and a target locating subsystem to accurately deliver radiation to the treatment target. The target locating system provides X-rays of the treatment area taken by a diagnostic X-ray system that lets the user know the position of the target. The CyberKnife VSI Systems use skull tracking, fiducial tracking, Xsight® Spine Tracking, Xsight® Lung Tracking, and Synchrony® Respiratory Tracking for dynamic positioning and pointing of the linear accelerator. The system uses a 6 MV linear accelerator to provide a dose rate up to 1000 MU/minute.
The Radixact Treatment Delivery System is a radiation therapy delivery system th
The Radixact Treatment Delivery System is a radiation therapy delivery system that provides Image Guided Radiation Therapy (IGRT) using integral megavoltage CTimaging capabilities and delivers helical (rotational) and fixed-angle (non-rotational) radiation therapy to tumors and other targeted tissues.The Radixact Treatment Delivery System is a prescription device that delivers radiation in accordance with a physician approved plan. The Radixact Treatment Delivery System does not diagnose disease, recommend treatment regimens or quantify treatment effectiveness. It is not intended for diagnostic use.
Software, Version 11.0, CyberKnife(Operating Software group for CyberKnife Treat
Software, Version 11.0, CyberKnife(Operating Software group for CyberKnife Treatment Delivery System)
The Onrad™ Treatment System is a radiation therapy system that integrates planni
The Onrad™ Treatment System is a radiation therapy system that integrates planning, dosecalculation, megavoltage CT imaging for IGRT functionality, and fixed beam (non-rotational)radiation therapy treatment capabilities into a single comprehensive system.The Onrad™ Treatment System is a prescription device. It delivers radiation in accordancewith a physician approved plan. The device does not diagnose disease, recommend treatmentregimens, or quantify treatment effectiveness. The megavoltage CT imaging functionality isnot intended for diagnostic use.
Software, CyberKnife Version 11.1 (Software group that operates CyberKnife Treat
Software, CyberKnife Version 11.1 (Software group that operates CyberKnife Treatment Delivery System)
The CyberKnife® Treatment Delivery System (CKTDS) is a computer-controlled radia
The CyberKnife® Treatment Delivery System (CKTDS) is a computer-controlled radiation treatment delivery system for performing minimally invasive stereotactic radiosurgery and precision radiotherapy. The CyberKnife Treatment Delivery System is intended to work with Accuray Precision® Treatment Planning System and iDMS™ Data Management System.
The TomoTherapy Treatment Delivery System with iDMS is indicated for the deliver
The TomoTherapy Treatment Delivery System with iDMS is indicated for the delivery of radiation therapy, stereotactic radiotherapy or stereotactic radiosurgery to tumors or other targeted tissues anywhere in the body under the direction of a licensed medical practitioner.
The TomoTherapy Treatment Delivery System with iDMS is indicated for the deliver
The TomoTherapy Treatment Delivery System with iDMS is indicated for the delivery of radiation therapy, stereotactic radiotherapy or stereotactic radiosurgery to tumors or other targeted tissues anywhere in the body under the direction of a licensed medical practitioner.
The TomoTherapy Treatment Delivery System with iDMS is indicated for the deliver
The TomoTherapy Treatment Delivery System with iDMS is indicated for the delivery of radiation therapy, stereotactic radiotherapy or stereotactic radiosurgery to tumors or other targeted tissues anywhere in the body under the direction of a licensed medical practitioner.
The CyberKnife VSI System is a computer controlled medical systems for planning
The CyberKnife VSI System is a computer controlled medical systems for planning and performing minimally invasive stereotactic radiosurgery and precision radiotherapy using a treatment radiation generator, linear accelerator, manipulator (robot), and a target locating subsystem to accurately deliver radiation to the treatment target. The target locating system provides X-rays of the treatment area taken by a diagnostic X-ray system that lets the user know the position of the target. The CyberKnife VSI Systems use skull tracking, fiducial tracking, Xsight® Spine Tracking, Xsight® Lung Tracking, and Synchrony® Respiratory Tracking for dynamic positioning and pointing of the linear accelerator. The system uses a 6 MV linear accelerator to provide a dose rate up to 1000 MU/minute.
Software, Version 2.0, iDMS Data Management SystemThe iDMS Data Management Syste
Software, Version 2.0, iDMS Data Management SystemThe iDMS Data Management System is indicated for the storage, retrieval, and processing of data utilized in the practice of radiotherapy, stereotactic radiotherapy and stereotactic radiosurgery.
Software, TomoApps, Version 2.1.1, Build # 5.1.1(Operating Software for TomoTher
Software, TomoApps, Version 2.1.1, Build # 5.1.1(Operating Software for TomoTherapy systems, including TomoH®, TomoHD®, TomoHDA™ and Onrad™)
Software, Version 1.1, iDMS™ Data Management SystemThe iDMS™ Data Management Sys
Software, Version 1.1, iDMS™ Data Management SystemThe iDMS™ Data Management System is indicated for the storage, retrieval, and processing of data utilized in the practice of radiotherapy, stereotactic radiotherapy and stereotactic radiosurgery.
Software, Version 1.0, iDMS™ Data Management SystemThe iDMS™ Data Management Sys
Software, Version 1.0, iDMS™ Data Management SystemThe iDMS™ Data Management System is indicated for the storage, retrieval, and processing of data utilized in the practice of radiotherapy, stereotactic radiotherapy and stereotactic radiosurgery.
Software, iDMS™ Data Management System, (Version 1.1.1.1)The iDMS™ Data Manageme
Software, iDMS™ Data Management System, (Version 1.1.1.1)The iDMS™ Data Management System is indicated for the storage, retrieval, and processing of data utilized in the practice of radiotherapy, stereotactic radiotherapy and stereotactic radiosurgery.
The CNMC Model 206 is a medical dosimeter, or medical electrometer that is capab
The CNMC Model 206 is a medical dosimeter, or medical electrometer that is capable of performing measurements of diagnostic and therapeutic amounts of ionizing radiation when an appropriate ionization chamber or diode dosimeter is connected.
Radiance V4 is a software system intended for treatment planning and analysis of
Radiance V4 is a software system intended for treatment planning and analysis of radiation therapy administered with devices suitable for intraoperative radiotherapy.The treatment plans provide treatment unit set-up parameters and estimates of dose distributions expected during the proposed treatment, and may be used to administer treatments after review and approval by the intended user.The system functionality can be configured based on user needs.The intended users of Radiance V4 shall be clinically qualified radiation therapy staff trained in using the system.
Radiance V3 is a software system intended for treatment planning and analysis of
Radiance V3 is a software system intended for treatment planning and analysis of radiation therapy administered with devices suitable for intraoperative radiotherapy.The treatment plans provide treatment unit set-up parameters and estimates of dose distributions expected during the proposed treatment, and may be used to administer treatments after review and approval by the intended user.The system functionality can be configured based on user needs.The intended users of Radiance V3 shall be clinically qualified radiation therapy staff trained in using the system.
The NOVAC 11 is an electron linear accelerator used for radiation therapy during
The NOVAC 11 is an electron linear accelerator used for radiation therapy duringsurgical procedures in an operating room for the treatment of malignant and benignconditions. Known as Intraoperative Radiation Therapy (IORT), this technique allowsdelivery of high doses of radiation directly aimed at tumors or other sites while avoidingdosage to surgically mobilized normal tissues.The NOVAC 11 is a mobile and articulated machine that can be moved towards thepatient and put in the appropriate position to carry out the necessary radiotherapy.
The absorber shields are discs used to radioprotect the patient’s organs. They s
The absorber shields are discs used to radioprotect the patient’s organs. They shall be inserted below the tissue treated during the surgery. They can be inserted within the surgical incision.
The absorber shields are discs used to radioprotect the patient’s organs. They s
The absorber shields are discs used to radioprotect the patient’s organs. They shall be inserted below the tissue treated during the surgery. They can be inserted within the surgical incision.
The absorber shields are discs used to radioprotect the patient’s organs. They s
The absorber shields are discs used to radioprotect the patient’s organs. They shall be inserted below the tissue treated during the surgery. They can be inserted within the surgical incision.
The absorber shields are discs used to radioprotect the patient’s organs. They s
The absorber shields are discs used to radioprotect the patient’s organs. They shall be inserted below the tissue treated during the surgery. They can be inserted within the surgical incision.
The absorber shields are discs used to radioprotect the patient’s organs. They s
The absorber shields are discs used to radioprotect the patient’s organs. They shall beinserted below the tissue treated during the surgery. They can be inserted within the surgicalincision.
The absorber shields are discs used to radioprotect the patient’s organs . They
The absorber shields are discs used to radioprotect the patient’s organs . They shall beinserted below the tissue treated during the surgery. They can be inserted within the surgicalincision.
LIAC is intended for use in radiation therapy in the operating theatre on a pati
LIAC is intended for use in radiation therapy in the operating theatre on a patient from whom the surgeon has just removed a neoplasia.The device may solely be used for oncological radiation therapy. The contraindications are related to use on non-oncological patients.To this end, the mobile structure with its equipment is moved to the patient at the appropriate time and placed in a position such that the applicator can be connected.At this point, the operating theatre is evacuated and the radiation command given from the console outside, after which the mobile structure is removed and surgery completed.The radiation time is normally not more than two minutes and therefore does not significantly affect the surgery time. The machine may only be used by radiation therapy or surgery staff previously trained for its use.In order to reduce the dose to the healthy tissues of the patient during the therapeutic treatment, the specific Abdominal Radiation Protection Screens must be used. The control console normally does not require sterilization but only regular cleaning.LIAC is intended to be used in a public and private health environment.LIAC is intended to be handled by trained personnel (operators)authorised by the user (authority responsible).
LIAC is intended for use in radiation therapy in the operating theatre on a pati
LIAC is intended for use in radiation therapy in the operating theatre on a patient from whom the surgeon has just removed a neoplasia.The device may solely be used for oncological radiation therapy. The contraindications are related to use on non-oncological patients.To this end, the mobile structure with its equipment is moved to the patient at the appropriate time and placed in a position such that the applicator can be connected.At this point, the operating theatre is evacuated and the radiation command given from the console outside, after which the mobile structure is removed and surgery completed.The radiation time is normally not more than two minutes and therefore does not significantly affect the surgery time. The machine may only be used by radiation therapy or surgery staff previously trained for its use.In order to reduce the dose to the healthy tissues of the patient during the therapeutic treatment, the specific Abdominal Radiation Protection Screens must be used. The control console normally does not require sterilization but only regular cleaning.LIAC is intended to be used in a public and private health environment.LIAC is intended to be handled by trained personnel (operators)authorised by the user (authority responsible).