Other products from "GRAMEDICA"
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 M621OW30LBS18MM0 GM-500-18 OW3.0LBS-18MM osteo-WEDGE 3.0mm x 18mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 3.0mm x 18mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. HWC,HRS Screw, Fixation, Bone,Plate, Fixation, Bone 2 osteo-WEDGE 3.0mm x 18mm Locking Bone Screw
2 M621OW30LBS10MM0 GM-500-10 OW3.0LBS-10MM osteo-WEDGE 3.0mm x 10mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 3.0mm x 10mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. HWC,HRS Screw, Fixation, Bone,Plate, Fixation, Bone 2 osteo-WEDGE 3.0mm x 10mm Locking Bone Screw
3 M621OW25LBS10MM0 GM-200-10 OW2.5LBS-10MM osteo-WEDGE 2.5mm x 10mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 2.5mm x 10mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. HWC,HRS Screw, Fixation, Bone,Plate, Fixation, Bone 2 osteo-WEDGE 2.5mm x 10mm Locking Bone Screw
4 M621OTSS0 OT-SS OT-SS The opti-Toe Small Straight Implant is comprised of two mated components (proxim The opti-Toe Small Straight Implant is comprised of two mated components (proximal and middle phalangeal) which join together to form a single intramedullary fixation unit. Indications: The GraMedica opti-Toe Device is indicate for reconstruction of the lesser toes following correction procedures for hammertoe, claw toe, and mallet toe. The GraMedica opti-Toe components are to be cemented in place and assembled for reconstruction of the toe. Patients should protect weight-bearing or heal bearing until healing has occurred. HTY Pin, Fixation, Smooth 2 opti-Toe Small Straight
5 M621OTSA0 OT-SA OT-SA The Opti-Toe-Small Angle Implant is comprised of two mated components (proximal The Opti-Toe-Small Angle Implant is comprised of two mated components (proximal and middle phalangeal) which join together to form a single intramedullary fixation unit. Indications: The GraMedica opti-Toe Device is indicate for reconstruction of the lesser toes following correction procedures for hammertoe, claw toe, and mallet toe. The GraMedica opti-Toe components are to be cemented in place and assembled for reconstruction of the toe. Patients should protect weight-bearing or heal bearing until healing has occurred. HTY Pin, Fixation, Smooth 2 Opti-Toe-Small Angle
6 M621HYPII070 HYP II-07 HYP II-07 HyProCure II Sinus Tarsi Implant Size 07. Indications: HyProCure II (HYP II a HyProCure II Sinus Tarsi Implant Size 07. Indications: HyProCure II (HYP II and HYP IIs) is an implant stabilization device used in the treatment of hyperpronating instability of the hindfoot. The implant is designed to stabilize the talus to prevent excessive anterior, and/or medial, and/or plantarflexion of the talus, while allowing normal talotarsal joint motion. HWC Screw, Fixation, Bone 2 HyProCure II Sinus Tarsi Stent Size 07
7 M621HYPII060 HYP II-06 HYP II-06 HyProCure II Sinus Tarsi Implant Size 06. Indications: HyProCure II (HYP II an HyProCure II Sinus Tarsi Implant Size 06. Indications: HyProCure II (HYP II and HYP IIs) is an implant stabilization device used in the treatment of hyperpronating instability of the hindfoot. The implant is designed to stabilize the talus to prevent excessive anterior, and/or medial, and/or plantarflexion of the talus, while allowing normal talotarsal joint motion. HWC Screw, Fixation, Bone 2 HyProCure II Sinus Tarsi Stent Size 06
8 M621GM504090 GM-504-09 GM-504-09 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. HRS,HWC Plate, Fixation, Bone,Screw, Fixation, Bone 2 osteo-WEDGE2 9 Degree Angulated Bone Plate Implant, Large
9 M621OW25LBS22MM0 GM-200-22 OW2.5LBS-22MM osteo-WEDGE 2.5mm x 22mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 2.5mm x 22mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. HWC,HRS Screw, Fixation, Bone,Plate, Fixation, Bone 2 osteo-WEDGE 2.5mm x 22mm Locking Bone Screw
10 M621OW25LBS20MM0 GM-200-20 OW2.5LBS-20MM osteo-WEDGE 2.5mm x 20mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 2.5mm x 20mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. HWC Screw, Fixation, Bone 2 osteo-WEDGE 2.5mm x 20mm Locking Bone Screw
11 M621OW25LBS14MM0 GM-200-14 OW2.5LBS-14MM osteo-WEDGE 2.5mm x 14mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 2.5mm x 14mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. HWC,HRS Screw, Fixation, Bone,Plate, Fixation, Bone 2 osteo-WEDGE 2.5mm x 14mm Locking Bone Screw
12 M621HYPSTDS0 11-363-11 11cm/4.5" HYP-ST-DS Reusable HyProCure SinusTarsi Decompression Scissors for dissecting and cutting Reusable HyProCure SinusTarsi Decompression Scissors for dissecting and cutting soft tissue. HRR Scissors, Orthopedic, Surgical 1 HYP Sinus Tarsi Decompression Scissors
13 M621HYPII50 HYP II-5 HYP II-5 HyProCure II Driver instrument. For use with the HyProCure II Sinus Tarsi Impla HyProCure II Driver instrument. For use with the HyProCure II Sinus Tarsi Implant System. Indications: The HyProCure II (HYP II and HYP IIs) Implant is an implant stabilization device used in the treatment of hyperpronating instability of the hindfoot. The implant is designed to stabilize the talus to prevent excessive anterior, and/or medial, and/or plantarflexion of the talus, while allowing normal talotarsal joint motion. HWC Screw, Fixation, Bone 2 HyProCure II Driver
14 M621HYPII080 HYP II-08 HYP II-08 HyProCure II Sinus Tarsi Implant Size 08. Indications: HyProCure II (HYP II a HyProCure II Sinus Tarsi Implant Size 08. Indications: HyProCure II (HYP II and HYP IIs) is an implant stabilization device used in the treatment of hyperpronating instability of the hindfoot. The implant is designed to stabilize the talus to prevent excessive anterior, and/or medial, and/or plantarflexion of the talus, while allowing normal talotarsal joint motion. HWC Screw, Fixation, Bone 2 HyProCure II Sinus Tarsi Stent Size 08
15 M621HYPGUIDEWIRES0 HYP-GuideWires HYP-GuideWires Guide Wire, a reusable instrument, for use with the HyProCure or HyProCure II Si Guide Wire, a reusable instrument, for use with the HyProCure or HyProCure II Sinus Tarsi Implant System. Indications: HyProCure is an implant stabilization device used in the treatment of hyperpronating instability of the hindfoot. The implant is designed to stabilize the talus to prevent excessive anterior, and/or medial, and/or plantarflexion of the talus, while allowing normal talotarsal joint motion. HWC Screw, Fixation, Bone 2 Guide Wire
16 M621HYP100 HYP-10 HYP-10 HyProCure Sinus Tarsi Implant Size 10. Indications: HyProCure is a talotarsa HyProCure Sinus Tarsi Implant Size 10. Indications: HyProCure is a talotarsal stabilization device used in the treatment of talotarsal dislocation and resulting sequela. The implant is designed to stabilize the talus on the tarsal mechanism to prevent excessive anterior, and/or medial, and/or plantarflexion of the talus on the tarsal mechanism, while allowing normal talotarsal joint motion. HWC Screw, Fixation, Bone 2 HyProCure Size 10
17 M621HYP080 HYP-08 HYP-08 HyProCure Sinus Tarsi Implant Size 08. Indications: HyProCure is a talotarsa HyProCure Sinus Tarsi Implant Size 08. Indications: HyProCure is a talotarsal stabilization device used in the treatment of talotarsal dislocation and resulting sequela. The implant is designed to stabilize the talus on the tarsal mechanism to prevent excessive anterior, and/or medial, and/or plantarflexion of the talus on the tarsal mechanism, while allowing normal talotarsal joint motion. HWC Screw, Fixation, Bone 2 HyProCure Size 08
18 M621GM504180 GM-504-18 GM-504-18 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. HRS,HWC Plate, Fixation, Bone,Screw, Fixation, Bone 2 osteo-WEDGE2 18 Degree Angulated Bone Plate Implant, Large
19 M621GM503210 GM-503-21 GM-503-21 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. HRS,HWC Plate, Fixation, Bone,Screw, Fixation, Bone 2 osteo-WEDGE2 21 Degree Angulated Bone Plate Implant, Small
20 M621GM503120 GM-503-12 GM-503-12 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. HRS,HWC Plate, Fixation, Bone,Screw, Fixation, Bone 2 osteo-WEDGE2 12 Degree Angulated Bone Plate Implant, Small
21 M621GM503090 GM-503-09 GM-503-09 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. HRS,HWC Plate, Fixation, Bone,Screw, Fixation, Bone 2 osteo-WEDGE2 9 Degree Angulated Bone Plate Implant, Small
22 M621GM150010 GM-150-01 GM-150-01 osteo-WEDGE Depth Gauge Sleeve, a reusable instrument, for use with the osteo-WE osteo-WEDGE Depth Gauge Sleeve, a reusable instrument, for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. HRS,HWC Plate, Fixation, Bone,Screw, Fixation, Bone 2 osteo-WEDGE Depth Gauge Sleeve
23 M621CP1510FG0 CP15-10-FG CP15-10-FG HyProCure Sizer 10. Reusable instrument, for use with the HyProCure Sinus Tar HyProCure Sizer 10. Reusable instrument, for use with the HyProCure Sinus Tarsi Implant System. Indications: HyProCure is a talotarsal stabilization device used in the treatment of talotarsal dislocation and resulting sequela. The implant is designed to stabilize the talus on the tarsal mechanism to prevent excessive anterior, and/or medial, and/or plantarflexion of the talus on the tarsal mechanism, while allowing normal talotarsal joint motion. HWC Screw, Fixation, Bone 2 HyProCure Sizer 10
24 M621CARRYINGCASE20 CarryingCase2 CarryingCase2 osteo-WEDGE2 Opening Wedge Bone Locking System -Kit (containing non-sterile sing osteo-WEDGE2 Opening Wedge Bone Locking System -Kit (containing non-sterile single use implants (2.5mm locking bone screws, 3.0mm locking bone screws and bone plates), non-sterile single use temporary tacks and non-sterile reusable instruments). The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. HWC,HRS Screw, Fixation, Bone,Plate, Fixation, Bone 2 osteo-WEDGE2 Open Wedge Bone Locking System
25 M621OW30LBS26MM0 GM-500-26 OW3.0LBS-26MM osteo-WEDGE 3.0mm x 26mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 3.0mm x 26mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. HWC,HRS Screw, Fixation, Bone,Plate, Fixation, Bone 2 osteo-WEDGE 3.0mm x 26mm Locking Bone Screw
26 M621OW30LBS14MM0 GM-500-14 OW3.0LBS-14MM osteo-WEDGE 3.0mm x 14mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 3.0mm x 14mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. HWC,HRS Screw, Fixation, Bone,Plate, Fixation, Bone 2 osteo-WEDGE 3.0mm x 14mm Locking Bone Screw
27 M621HYPIITS120 HYP II-TS-12 HYP II-TS-12 HyProCure II Trial Sizer 12 instrument. For use with the HyProCure II Sinus Tar HyProCure II Trial Sizer 12 instrument. For use with the HyProCure II Sinus Tarsi Implant System. Indications: The HyProCure II (HYP II and HYP IIs) Implant is an implant stabilization device used in the treatment of hyperpronating instability of the hindfoot. The implant is designed to stabilize the talus to prevent excessive anterior, and/or medial, and/or plantarflexion of the talus, while allowing normal talotarsal joint motion. HWC Screw, Fixation, Bone 2 HyProCure II Trial Sizer 12
28 M621HYPIIINSTRAY0 HYPII-INS-TRAY HYPII-INS-TRAY HyProCure II (reusable) Instrument Tray-Kit. The Instrument kit contains seven HyProCure II (reusable) Instrument Tray-Kit. The Instrument kit contains seven Trial Sizers (06mm thru 12mm) one Driver, one Positioning Sleeve and three Guide Wires). For use with the HyProCure II Sinus Tarsi Implants. Indications: The HyProCure II (HYP II and HYP IIs) Implant is an implant stabilization device used in the treatment of hyperpronating instability of the hindfoot. The implant is designed to stabilize the talus to prevent excessive anterior, and/or medial, and/or plantarflexion of the talus, while allowing normal talotarsal joint motion HWC Screw, Fixation, Bone 2 HyProCure II Instrument Tray-Set
29 M621GM503030 GM-503-03 GM-503-03 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. HRS,HWC Plate, Fixation, Bone,Screw, Fixation, Bone 2 osteo-WEDGE2 3 Degree Angulated Bone Plate Implant, Small
30 M621GM501040 GM-501-04 GM-501-04 osteo-WEDGE Bone Plate 04mm. Non-sterile single use implant for use with the os osteo-WEDGE Bone Plate 04mm. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. HRS,HWC Plate, Fixation, Bone,Screw, Fixation, Bone 2 osteo-WEDGE Bone Plate 04mm
31 M621GM501000 GM-501-00 GM-501-00 osteo-WEDGE Bone Plate 00mm. Non-sterile single use implant for use with the os osteo-WEDGE Bone Plate 00mm. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. HRS,HWC Plate, Fixation, Bone,Screw, Fixation, Bone 2 osteo-WEDGE Bone Plate 00mm
32 M621CP1505FG0 CP15-05-FG CP15-05-FG HyProCure Sizer 05. Reusable instrument, for use with the HyProCure Sinus Tarsi HyProCure Sizer 05. Reusable instrument, for use with the HyProCure Sinus Tarsi Implant System. Indications: HyProCure is a talotarsal stabilization device used in the treatment of talotarsal dislocation and resulting sequela. The implant is designed to stabilize the talus on the tarsal mechanism to prevent excessive anterior, and/or medial, and/or plantarflexion of the talus on the tarsal mechanism, while allowing normal talotarsal joint motion. HWC Screw, Fixation, Bone 2 HyProCure Sizer 05
33 M621CARRYINGCASE0 OWCarryingCase-Kit CarryingCase osteo-WEDGE Opening Wedge Bone Locking System -Kit (containing non-sterile singl osteo-WEDGE Opening Wedge Bone Locking System -Kit (containing non-sterile single use implants (2.5mm locking bone screws, 3.0mm locking bone screws and bone plates), non-sterile single use temporary tacks and non-sterile reusable instruments). The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. HRS,HWC Plate, Fixation, Bone,Screw, Fixation, Bone 2 osteo-WEDGE Opening Wedge Bone Locking System
34 M621OW30LBS08MM0 GM-500-08 OW3.0LBS-08MM osteo-WEDGE 3.0mm x 08mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 3.0mm x 08mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. HWC,HRS Screw, Fixation, Bone,Plate, Fixation, Bone 2 osteo-WEDGE 3.0mm x 08mm Locking Bone Screw
35 M621OW25LBS12MM0 GM-200-12 OW2.5LBS-12MM osteo-WEDGE 2.5mm x 12mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 2.5mm x 12mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. HWC,HRS Screw, Fixation, Bone,Plate, Fixation, Bone 2 osteo-WEDGE 2.5mm x 12mm Locking Bone Screw
36 M621HYPIITS100 HYP II-TS-10 HYP II-TS-10 HyProCure II Trial Sizer 10 instrument. For use with the HyProCure II Sinus Tar HyProCure II Trial Sizer 10 instrument. For use with the HyProCure II Sinus Tarsi Implant System. Indications: The HyProCure II (HYP II and HYP IIs) Implant is an implant stabilization device used in the treatment of hyperpronating instability of the hindfoot. The implant is designed to stabilize the talus to prevent excessive anterior, and/or medial, and/or plantarflexion of the talus, while allowing normal talotarsal joint motion. HWC Screw, Fixation, Bone 2 HyProCure II Trial Sizer 10
37 M621HYPII110 HYP II-11 HYP II-11 HyProCure II Sinus Tarsi Implant Size 11. Indications: HyProCure II (HYP II a HyProCure II Sinus Tarsi Implant Size 11. Indications: HyProCure II (HYP II and HYP IIs) is an implant stabilization device used in the treatment of hyperpronating instability of the hindfoot. The implant is designed to stabilize the talus to prevent excessive anterior, and/or medial, and/or plantarflexion of the talus, while allowing normal talotarsal joint motion. HWC Screw, Fixation, Bone 2 HyProCure II Sinus Tarsi Stent Size 11
38 M621HYPII100 HYP II-10 HYP II-10 HyProCure II Sinus Tarsi Implant Size 10. Indications: HyProCure II (HYP II a HyProCure II Sinus Tarsi Implant Size 10. Indications: HyProCure II (HYP II and HYP IIs) is an implant stabilization device used in the treatment of hyperpronating instability of the hindfoot. The implant is designed to stabilize the talus to prevent excessive anterior, and/or medial, and/or plantarflexion of the talus, while allowing normal talotarsal joint motion. HWC Screw, Fixation, Bone 2 HyProCure II Sinus Tarsi Stent Size 10
39 M621HYP050 HYP-05 HYP-05 HyProCure Sinus Tarsi Implant Size 05. Indications: HyProCure is a talotarsal HyProCure Sinus Tarsi Implant Size 05. Indications: HyProCure is a talotarsal stabilization device used in the treatment of talotarsal dislocation and resulting sequela. The implant is designed to stabilize the talus on the tarsal mechanism to prevent excessive anterior, and/or medial, and/or plantarflexion of the talus on the tarsal mechanism, while allowing normal talotarsal joint motion. HWC Screw, Fixation, Bone 2 HyProCure Size 05
40 M621GMDSLS0 11-470-11-S (14cm/5.5") GM-DS-LS Reusable Graham Decompression Scissors, straight, for cutting soft tissue. HRR Scissors, Orthopedic, Surgical 1 Graham Decompression Scissors, Straight
41 M621GM504150 GM-504-15 GM-504-15 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. HRS,HWC Plate, Fixation, Bone,Screw, Fixation, Bone 2 osteo-WEDGE2 15 Degree Angulated Bone Plate Implant, Large
42 M621GM503060 GM-503-06 GM-503-06 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. HRS,HWC Plate, Fixation, Bone,Screw, Fixation, Bone 2 osteo-WEDGE2 6 Degree Angulated Bone Plate Implant, Small
43 M621GM160040 GM-160-04 GM-160-04 osteo-WEDGE2 Drill Guide, a reusable instrument, for use with the osteo-WEDGE O osteo-WEDGE2 Drill Guide, a reusable instrument, for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. HRS,HWC Plate, Fixation, Bone,Screw, Fixation, Bone 2 osteo-WEDGE2 Drill Guide
44 M621GM160030 GM-160-03 GM-160-03 osteo-WEDGE2 Drill Guide, a reusable instrument, for use with the osteo-WEDGE O osteo-WEDGE2 Drill Guide, a reusable instrument, for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. HRS,HWC Plate, Fixation, Bone,Screw, Fixation, Bone 2 osteo-WEDGE2 Drill Guide
45 M621CP1509FG0 CP15-09-FG CP15-09-FG HyProCure Sizer 09. Reusable instrument, for use with the HyProCure Sinus Tars HyProCure Sizer 09. Reusable instrument, for use with the HyProCure Sinus Tarsi Implant System. Indications: HyProCure is a talotarsal stabilization device used in the treatment of talotarsal dislocation and resulting sequela. The implant is designed to stabilize the talus on the tarsal mechanism to prevent excessive anterior, and/or medial, and/or plantarflexion of the talus on the tarsal mechanism, while allowing normal talotarsal joint motion. HWC Screw, Fixation, Bone 2 HyProCure Sizer 09
46 M621OW30LBS24MM0 GM-500-24 OW3.0LBS-24MM osteo-WEDGE 3.0mm x 24mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 3.0mm x 24mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. HWC,HRS Screw, Fixation, Bone,Plate, Fixation, Bone 2 osteo-WEDGE 3.0mm x 24mm Locking Bone Screw
47 M621OW24TT12MM0 GM-100-12 OW2.4TT-12MM osteo-WEDGE Temporary Tack, 2.4mm x 12mm. Non-sterile single use (disposable) a osteo-WEDGE Temporary Tack, 2.4mm x 12mm. Non-sterile single use (disposable) accessory for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. HWC,HRS Screw, Fixation, Bone,Plate, Fixation, Bone 2 osteo-WEDGE Temporary Tack 2.4mm x 12mm
48 M621HYPIITS110 HYP II-TS-11 HYP II-TS-11 HyProCure II Trial Sizer 11 instrument. For use with the HyProCure II Sinus Tar HyProCure II Trial Sizer 11 instrument. For use with the HyProCure II Sinus Tarsi Implant System. Indications: The HyProCure II (HYP II and HYP IIs) Implant is an implant stabilization device used in the treatment of hyperpronating instability of the hindfoot. The implant is designed to stabilize the talus to prevent excessive anterior, and/or medial, and/or plantarflexion of the talus, while allowing normal talotarsal joint motion.. HWC Screw, Fixation, Bone 2 HyProCure II Trial Sizer 11
49 M621HYPIITS080 HYP II-TS-08 HYP II-TS-08 HyProCure II Trial Sizer 08 instrument. For use with the HyProCure II Sinus Tar HyProCure II Trial Sizer 08 instrument. For use with the HyProCure II Sinus Tarsi Implants. The HyProCure II (HYP II and HYP IIs) Sinus Tarsi Implant system is an implant stabilization device used in the treatment of hyperpronating instability of the hindfoot. The implant is designed to stabilize the talus to prevent excessive anterior, and/or medial, and/or plantarflexion of the talus, while allowing normal talotarsal joint motion. HWC Screw, Fixation, Bone 2 HyProCure II Trial Sizer 08
50 M621HYPIIPS0 HYPII-PS HYPII-PS HyProCure II Positioning Sleeve instrument. For use with the HyProCure II Sinus HyProCure II Positioning Sleeve instrument. For use with the HyProCure II Sinus Tarsi Implant System. Indications: The HyProCure II (HYP II and HYP IIs) Implant is an implant stabilization device used in the treatment of hyperpronating instability of the hindfoot. The implant is designed to stabilize the talus to prevent excessive anterior, and/or medial, and/or plantarflexion of the talus, while allowing normal talotarsal joint motion. HWC Screw, Fixation, Bone 2 HyProCure II Positioning Sleeve
Other products with the same Product Codes "HWC, HRS"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 04050659536531 SO-1002-17 TI Snap-off Screw,self-drilling+ _x000D_tapping,17mm TI Snap-off Screw,self-drilling+ _x000D_tapping,17mm _x000D_ mahe medical GmbH MAHE MEDICAL GMBH
2 04050659536517 SO-1002-16 TI Snap-off Screw,self-drilling+ _x000D_tapping,16mm TI Snap-off Screw,self-drilling+ _x000D_tapping,16mm _x000D_ mahe medical GmbH MAHE MEDICAL GMBH
3 04050659536494 SO-1002-15 TI Snap-off Screw,self-drilling+ _x000D_tapping,15mm TI Snap-off Screw,self-drilling+ _x000D_tapping,15mm _x000D_ mahe medical GmbH MAHE MEDICAL GMBH
4 04050659536470 SO-1002-14 TI Snap-off Screw,self-drilling+ _x000D_tapping,14mm TI Snap-off Screw,self-drilling+ _x000D_tapping,14mm _x000D_ mahe medical GmbH MAHE MEDICAL GMBH
5 04050659536456 SO-1002-13 TI Snap-off Screw,self-drilling+ _x000D_tapping,13mm TI Snap-off Screw,self-drilling+ _x000D_tapping,13mm _x000D_ mahe medical GmbH MAHE MEDICAL GMBH
6 04050659536432 SO-1002-12 TI Snap-off Screw,self-drilling+ _x000D_tapping,12mm TI Snap-off Screw,self-drilling+ _x000D_tapping,12mm _x000D_ mahe medical GmbH MAHE MEDICAL GMBH
7 04050659536418 SO-1002-11 TI Snap-off Screw,self-drilling+ _x000D_tapping,11mm TI Snap-off Screw,self-drilling+ _x000D_tapping,11mm _x000D_ mahe medical GmbH MAHE MEDICAL GMBH
8 04050659536395 SO-1002-10 TI Snap-off Screw,self-drilling+ _x000D_tapping,10mm TI Snap-off Screw,self-drilling+ _x000D_tapping,10mm _x000D_ mahe medical GmbH MAHE MEDICAL GMBH
9 04050659485921 KW-1000-080 HBS-Guide Wire ø 1.0x80mm _x000D_ HBS-Guide Wire ø 1.0x80mm _x000D_ _x000D_ mahe medical GmbH MAHE MEDICAL GMBH
10 04050659465794 HBS-1003-30S TI HBS self-drilling high compression _x000D_screw,cannulated,30mm TI HBS self-drilling high compression _x000D_screw,cannulated,30mm _x000D_Ø3.2/2.5mm mahe medical GmbH MAHE MEDICAL GMBH
11 04050659465770 HBS-1003-28S TI HBS self-drilling high compression _x000D_screw,cannulated,28mm TI HBS self-drilling high compression _x000D_screw,cannulated,28mm _x000D_Ø3.2/2.5mm mahe medical GmbH MAHE MEDICAL GMBH
12 04050659465756 HBS-1003-26S TI HBS self-drilling high compression _x000D_screw,cannulated,26mm TI HBS self-drilling high compression _x000D_screw,cannulated,26mm _x000D_Ø3.2/2.5mm mahe medical GmbH MAHE MEDICAL GMBH
13 04050659465732 HBS-1003-24S TI HBS self-drilling high compression _x000D_screw,cannulated,24mm TI HBS self-drilling high compression _x000D_screw,cannulated,24mm _x000D_Ø3.2/2.5mm mahe medical GmbH MAHE MEDICAL GMBH
14 04050659465718 HBS-1003-22S TI HBS self-drilling high compression _x000D_screw,cannulated,22mm TI HBS self-drilling high compression _x000D_screw,cannulated,22mm _x000D_Ø3.2/2.5mm mahe medical GmbH MAHE MEDICAL GMBH
15 04050659465695 HBS-1003-20S TI HBS self-drilling high compression _x000D_screw,cannulated,20mm TI HBS self-drilling high compression _x000D_screw,cannulated,20mm _x000D_Ø3.2/2.5mm mahe medical GmbH MAHE MEDICAL GMBH
16 04050659465671 HBS-1003-18S TI HBS self-drilling high compression _x000D_screw,cannulated,18mm TI HBS self-drilling high compression _x000D_screw,cannulated,18mm _x000D_Ø3.2/2.5mm mahe medical GmbH MAHE MEDICAL GMBH
17 04050659465657 HBS-1003-16S TI HBS self-drilling high compression _x000D_screw,cannulated,16mm TI HBS self-drilling high compression _x000D_screw,cannulated,16mm _x000D_Ø3.2/2.5mm mahe medical GmbH MAHE MEDICAL GMBH
18 04050659465633 HBS-1003-14S TI HBS self-drilling high compression _x000D_screw,cannulated,14mm TI HBS self-drilling high compression _x000D_screw,cannulated,14mm _x000D_Ø3.2/2.5mm mahe medical GmbH MAHE MEDICAL GMBH
19 04050659465619 HBS-1003-12S TI HBS self-drilling high compression _x000D_screw,cannulated,12mm TI HBS self-drilling high compression _x000D_screw,cannulated,12mm _x000D_Ø3.2/2.5mm mahe medical GmbH MAHE MEDICAL GMBH
20 04050659465596 HBS-1003-10S TI HBS self-drilling high compression _x000D_screw,cannulated,10mm TI HBS self-drilling high compression _x000D_screw,cannulated,10mm _x000D_Ø3.2/2.5mm mahe medical GmbH MAHE MEDICAL GMBH
21 04050659465510 HBS-1002-40S TI HBS self-drilling high compression _x000D_screw,cannulated,40mm TI HBS self-drilling high compression _x000D_screw,cannulated,40mm _x000D_ mahe medical GmbH MAHE MEDICAL GMBH
22 04050659465497 HBS-1002-38S TI HBS self-drilling high compression _x000D_screw,cannulated,38mm TI HBS self-drilling high compression _x000D_screw,cannulated,38mm _x000D_ mahe medical GmbH MAHE MEDICAL GMBH
23 04050659465473 HBS-1002-36S TI HBS self-drilling high compression _x000D_screw,cannulated,36mm TI HBS self-drilling high compression _x000D_screw,cannulated,36mm _x000D_ mahe medical GmbH MAHE MEDICAL GMBH
24 04050659465459 HBS-1002-34S TI HBS self-drilling high compression _x000D_screw,cannulated,34mm TI HBS self-drilling high compression _x000D_screw,cannulated,34mm _x000D_ mahe medical GmbH MAHE MEDICAL GMBH
25 04050659465435 HBS-1002-32S TI HBS self-drilling high compression _x000D_screw,cannulated,32mm TI HBS self-drilling high compression _x000D_screw,cannulated,32mm _x000D_ mahe medical GmbH MAHE MEDICAL GMBH
26 04050659465411 HBS-1002-30S TI HBS self-drilling high compression _x000D_screw,cannulated,30mm TI HBS self-drilling high compression _x000D_screw,cannulated,30mm _x000D_ mahe medical GmbH MAHE MEDICAL GMBH
27 04050659465398 HBS-1002-28S TI HBS self-drilling high compression _x000D_screw,cannulated,28mm TI HBS self-drilling high compression _x000D_screw,cannulated,28mm _x000D_ mahe medical GmbH MAHE MEDICAL GMBH
28 04050659465374 HBS-1002-26S TI HBS self-drilling high compression _x000D_screw,cannulated,26mm TI HBS self-drilling high compression _x000D_screw,cannulated,26mm _x000D_ mahe medical GmbH MAHE MEDICAL GMBH
29 04050659465350 HBS-1002-24S TI HBS self-drilling high compression _x000D_screw,cannulated,24mm TI HBS self-drilling high compression _x000D_screw,cannulated,24mm _x000D_ mahe medical GmbH MAHE MEDICAL GMBH
30 04050659465336 HBS-1002-22S TI HBS self-drilling high compression _x000D_screw,cannulated,22mm TI HBS self-drilling high compression _x000D_screw,cannulated,22mm _x000D_ mahe medical GmbH MAHE MEDICAL GMBH
31 04050659465329 HBS-1002-20S-ST5 TI HBS self-drilling high compression _x000D_screw,cannulated,20mm,5 pcs./unit TI HBS self-drilling high compression _x000D_screw,cannulated,20mm,5 pcs./unit _x000D_ mahe medical GmbH MAHE MEDICAL GMBH
32 04050659465305 HBS-1002-20S TI HBS self-drilling high compression _x000D_screw,cannulated,20mm TI HBS self-drilling high compression _x000D_screw,cannulated,20mm _x000D_ mahe medical GmbH MAHE MEDICAL GMBH
33 04050659465282 HBS-1002-18S-ST5 TI HBS self-drilling high compression _x000D_screw,cannulated,18mm,5 pcs./unit TI HBS self-drilling high compression _x000D_screw,cannulated,18mm,5 pcs./unit _x000D_ mahe medical GmbH MAHE MEDICAL GMBH
34 04050659465268 HBS-1002-18S TI HBS self-drilling high compression _x000D_screw,cannulated,18mm TI HBS self-drilling high compression _x000D_screw,cannulated,18mm _x000D_ mahe medical GmbH MAHE MEDICAL GMBH
35 04050659465251 HBS-1002-16S-ST5 TI HBS self-drilling high compression _x000D_screw,cannulated,16mm,5 pcs./unit TI HBS self-drilling high compression _x000D_screw,cannulated,16mm,5 pcs./unit _x000D_ mahe medical GmbH MAHE MEDICAL GMBH
36 04050659465237 HBS-1002-16S TI HBS self-drilling high compression _x000D_screw,cannulated,16mm TI HBS self-drilling high compression _x000D_screw,cannulated,16mm _x000D_ mahe medical GmbH MAHE MEDICAL GMBH
37 04050659465213 HBS-1002-14S TI HBS self-drilling high compression _x000D_screw,cannulated,14mm TI HBS self-drilling high compression _x000D_screw,cannulated,14mm _x000D_ mahe medical GmbH MAHE MEDICAL GMBH
38 04050659465190 HBS-1002-12S TI HBS self-drilling high compression _x000D_screw,cannulated,12mm TI HBS self-drilling high compression _x000D_screw,cannulated,12mm _x000D_ mahe medical GmbH MAHE MEDICAL GMBH
39 04050659433731 932999016 Dia. 7.0/3.9mm Washer s/s _x000D_ Dia. 7.0/3.9mm Washer s/s _x000D_ _x000D_ mahe medical GmbH MAHE MEDICAL GMBH
40 04050659433724 932999015 6.5mm Washer s/s for 2.7mm screws _x000D_ 6.5mm Washer s/s for 2.7mm screws _x000D_ _x000D_ mahe medical GmbH MAHE MEDICAL GMBH
41 04050659433717 932999014 2.7mm Ligament Washer-Spiked _x000D_ 2.7mm Ligament Washer-Spiked _x000D_ _x000D_ mahe medical GmbH MAHE MEDICAL GMBH
42 04050659433250 931140014 Cancellous screws (full thread),4.0/14mm_x000D_'fat neck' Cancellous screws (full thread),4.0/14mm_x000D_'fat neck' _x000D_ mahe medical GmbH MAHE MEDICAL GMBH
43 04050659432741 930545034 Screw 4.5 x 34mm s/s _x000D_self-tapping Screw 4.5 x 34mm s/s _x000D_self-tapping _x000D_ mahe medical GmbH MAHE MEDICAL GMBH
44 04050659432710 930545028 Screw 4.5 x 28mm s/s _x000D_self-tapping Screw 4.5 x 28mm s/s _x000D_self-tapping _x000D_ mahe medical GmbH MAHE MEDICAL GMBH
45 04050659432680 930545022 Screw 4.5 x 22mm s/s _x000D_self-tapping Screw 4.5 x 22mm s/s _x000D_self-tapping _x000D_ mahe medical GmbH MAHE MEDICAL GMBH
46 04050659349766 200-0247-372 2.7mm LCP (TM) Plate 8 Holes _x000D_ 2.7mm LCP (TM) Plate 8 Holes _x000D_ _x000D_ mahe medical GmbH MAHE MEDICAL GMBH
47 04050659349759 200-0241-005 3.5mm Proximal Tibia Plate 4 Holes Left 3.5mm Proximal Tibia Plate 4 Holes Left _x000D_ _x000D_ mahe medical GmbH MAHE MEDICAL GMBH
48 04050659349742 200-0241-004 3.5mm Proximal Tibia Plate 4 Holes Right 3.5mm Proximal Tibia Plate 4 Holes Right _x000D_ _x000D_ mahe medical GmbH MAHE MEDICAL GMBH
49 04050659349735 200-0224-756 4.5mm/3.5mm LCP Metaphyseal Plate _x000D 4.5mm/3.5mm LCP Metaphyseal Plate _x000D_ _x000D_ mahe medical GmbH MAHE MEDICAL GMBH
50 04050659349728 200-0224-755 4.5mm/3.5mm LCP Metaphyseal Plate _x000D_ 4.5mm/3.5mm LCP Metaphyseal Plate _x000D_ _x000D_ mahe medical GmbH MAHE MEDICAL GMBH