No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 M58800101005611 1 001-010056-1 "The Vdrive® system is intended to stabilize, navigate and remotely control: • C "The Vdrive® system is intended to stabilize, navigate and remotely control: • Compatible Intracardiac Echocardiography (ICE) catheters to facilitate visualization of cardiac structure during theperformance of cardiac procedure when used in conjunction with the V-Sono™ disposable sets in the Vdrive® system, • Compatible loop (circular) mapping catheters to facilitate movement of the catheter during the performance ofelectrophysiological procedures when used in conjunction with the V-Loop™ disposable sets in the Vdrive® system, and • Compatible fixed curve transseptal sheaths and catheters to facilitate movement of the sheath and catheter when usedin conjunction with the V-CAS™ disposable sets in the Vdrive® system and with the Niobe® Magnetic NavigationSystem (MNS). " DXX,DQX System, Catheter Control, Steerable,Wire, Guide, Catheter Vdrive Drape
2 M58800100245210 1 001-002452-1 The Vdrive with V-Loop disposable is indicated to remotely control the advanceme The Vdrive with V-Loop disposable is indicated to remotely control the advancement, retraction, rotation, tip deflection and loop size of compatibile loop catheters inserted across the septum into the left atrium using conventional procedures DXX,DQX System, Catheter Control, Steerable,Wire, Guide, Catheter 2 V-Loop Variable Loop Catheter Manipulator
3 M5880010017711 1 001-001771-1 The Stereotaxis Cardiodrive is intended for automatically advancing and retracti The Stereotaxis Cardiodrive is intended for automatically advancing and retracting only compatible magnetic electrophysiology (EP) mapping and ablation catheters inside the patient's heart when used in conjunction with a Stereotaxis Magnetic Navigation System (MNS). It is not intended to advance the EP mapping and ablation catheters through the coronary vasculature nor the coronary sinus. DQX Wire, Guide, Catheter QuikCAS Hemostasis Adapter
4 M58800100784010 Studio 001-007840-1 The Odyssey Workstation is an optional display and user interface package design The Odyssey Workstation is an optional display and user interface package designed to consolidate the point of control in the Catheter Lab OUG Medical Device Data System 1 Odyssey Cinema
5 M58800100246910 1 001-002469-1 Vdrive with V-Sono is indicated for remotely controlling the advancement, retrac Vdrive with V-Sono is indicated for remotely controlling the advancement, retraction, rotation and anterior-posterior deflection of compatible ultrasound catheters inserted into the right atrium DXX,DQX System, Catheter Control, Steerable,Wire, Guide, Catheter 2 V-Sono Intracardiac Echo Manipulator
6 M58800100790010 Link 001-007900-1 The Odyssey Workstation is an optional display and user interface package design The Odyssey Workstation is an optional display and user interface package designed to consolidate the point of control in the Catheter Lab OUG Medical Device Data System 1 Odyssey
7 M58800100242210 1 001-002422-1 The Vdrive with V-CAS Disposable is indicated for remotely controlling the advan The Vdrive with V-CAS Disposable is indicated for remotely controlling the advancement, retraction, and rotation of compatible magnetic electrophysiology (EP) mapping and ablation catheters inside the patient's heart when used in conjunction with a Stereotaxis Magnetic Navigation System DXX,DQX System, Catheter Control, Steerable,Wire, Guide, Catheter 2 V-CAS Catheter Advancement System
8 M58802000780030 DMS-100 020-007800-3 The Odyssey Workstation is an optional display and user interface package design The Odyssey Workstation is an optional display and user interface package designed to consolidate the point of control in the Catheter Lab OUG Medical Device Data System 1 Cinema MAS & MMS
9 M588020004500360 5.0.7 020-004500-36 The Navigant Navigation Workstation (NWS) is a component of the Magnetic Navigat The Navigant Navigation Workstation (NWS) is a component of the Magnetic Navigation System (MNS). The MNS with NWS is intended to navigate compatible magnetic devices through tissue to designated target sites in the right and left heart and coronary vasculature by orienting the device tip in a desired direction. The Navigant feature provides an enhanced navigation interface for the physician to control the MNS. NDQ System, Catheter Or Guidewire, Steerable (Magnetic) 2 Navigant
10 M588020004500260 5.0.2 020-004500-26 The Navigant Navigation Workstation is a component of the Niobe MNS. The Niobe M The Navigant Navigation Workstation is a component of the Niobe MNS. The Niobe MNS with NWS is intended to navigate compatible magnetic devices through tissue to designated target sites in the right and left heart and coronary vasculature by orienting the device tip in a desired direction. The Navigant feature provides an enhanced navigation interface for the physician to control the MNS NDQ System, Catheter Or Guidewire, Steerable (Magnetic) 2 Navigant
11 M588020004500220 4.6.5 020-004500-22 The Navigant Navigation Workstation is a component of the Niobe MNS. The Niobe M The Navigant Navigation Workstation is a component of the Niobe MNS. The Niobe MNS with NWS is intended to navigate compatible magnetic devices through tissue to designated target sites in the right and left heart and coronary vasculature by orienting the device tip in a desired direction. The Navigant feature provides an enhanced navigation interface for the physician to control the MNS NDQ System, Catheter Or Guidewire, Steerable (Magnetic) 2 Navigant
12 M588020004500210 4.6.4 020-004500-21 The Navigant Navigation Workstation is a component of the Niobe MNS. The Niobe M The Navigant Navigation Workstation is a component of the Niobe MNS. The Niobe MNS with NWS is intended to navigate compatible magnetic devices through tissue to designated target sites in the right and left heart and coronary vasculature by orienting the device tip in a desired direction. The Navigant feature provides an enhanced navigation interface for the physician to control the MNS NDQ System, Catheter Or Guidewire, Steerable (Magnetic) 2 Navigant
13 M58800100230720 Duo 001-002307-2 "The Vdrive® system is intended to stabilize, navigate and remotely control: • C "The Vdrive® system is intended to stabilize, navigate and remotely control: • Compatible Intracardiac Echocardiography (ICE) catheters to facilitate visualization of cardiac structure during theperformance of cardiac procedure when used in conjunction with the V-Sono™ disposable sets in the Vdrive® system, • Compatible loop (circular) mapping catheters to facilitate movement of the catheter during the performance ofelectrophysiological procedures when used in conjunction with the V-Loop™ disposable sets in the Vdrive® system, and • Compatible fixed curve transseptal sheaths and catheters to facilitate movement of the sheath and catheter when usedin conjunction with the V-CAS™ disposable sets in the Vdrive® system and with the Niobe® Magnetic NavigationSystem (MNS). " DXX,DQX System, Catheter Control, Steerable,Wire, Guide, Catheter 2 Vdrive System
14 M58800100610010 ES Philips 001-006100-1 Stereotaxis Niobe Magnetic Navigation System (MNS) with Navigant Navigation Work Stereotaxis Niobe Magnetic Navigation System (MNS) with Navigant Navigation Workstation. The Niobe MNS with Navigant NWS is intended to navigate compatible magnetic devices through tissue to designated target sites in the right and left heart, coronary vasculature, neurovasculature and peripheral vasculature by orienting the device tip in a desired direction NDQ System, Catheter Or Guidewire, Steerable (Magnetic) 2 Niobe MNS Philips
15 M58800100230710 Single Arm 001-002307-1 "The Vdrive® system is intended to stabilize, navigate and remotely control: • C "The Vdrive® system is intended to stabilize, navigate and remotely control: • Compatible Intracardiac Echocardiography (ICE) catheters to facilitate visualization of cardiac structure during theperformance of cardiac procedure when used in conjunction with the V-Sono™ disposable sets in the Vdrive® system, • Compatible loop (circular) mapping catheters to facilitate movement of the catheter during the performance ofelectrophysiological procedures when used in conjunction with the V-Loop™ disposable sets in the Vdrive® system, and • Compatible fixed curve transseptal sheaths and catheters to facilitate movement of the sheath and catheter when usedin conjunction with the V-CAS™ disposable sets in the Vdrive® system and with the Niobe® Magnetic NavigationSystem (MNS). " DXX,DQX System, Catheter Control, Steerable,Wire, Guide, Catheter 2 Vdrive System
16 M58800100175110 1 001-001751-1 The Stereotaxis Cardiodrive is intended for automatically advancing and retracti The Stereotaxis Cardiodrive is intended for automatically advancing and retracting only compatible magnetic electrophysiology (EP) mapping and ablation catheters inside the patient's heart when used in conjunction with a Stereotaxis Magnetic Navigation System (MNS). It is not intended to advance the EP mapping and ablation catheters through the coronary vasculature nor the coronary sinus. DQX Wire, Guide, Catheter 2 QuikCAS Cardiodrive Sterile Components
17 M58800100411590 II 001-004115-9 The Stereotaxis Cardiodrive is intended for automatically advancing and retracti The Stereotaxis Cardiodrive is intended for automatically advancing and retracting only compatible magnetic electrophysiology (EP) mapping and ablation catheters inside the patient's heart when used in conjunction with a Stereotaxis Magnetic Navigation System (MNS). It is not intended to advance the EP mapping and ablation catheters through the coronary vasculature nor the coronary sinus. DQX Wire, Guide, Catheter 2 Cardiodrive System
18 M588001004115120 II 001-004115-12 The Stereotaxis Cardiodrive is intended for automatically advancing and retracti The Stereotaxis Cardiodrive is intended for automatically advancing and retracting only compatible magnetic electrophysiology (EP) mapping and ablation catheters inside the patient's heart when used in conjunction with a Stereotaxis Magnetic Navigation System (MNS). It is not intended to advance the EP mapping and ablation catheters through the coronary vasculature nor the coronary sinus. DQX Wire, Guide, Catheter 2 Cardiodrive System
19 M588001004115110 II 001-004115-11 The Stereotaxis Cardiodrive is intended for automatically advancing and retracti The Stereotaxis Cardiodrive is intended for automatically advancing and retracting only compatible magnetic electrophysiology (EP) mapping and ablation catheters inside the patient's heart when used in conjunction with a Stereotaxis Magnetic Navigation System (MNS). It is not intended to advance the EP mapping and ablation catheters through the coronary vasculature nor the coronary sinus. DQX Wire, Guide, Catheter 2 Cardiodrive System
20 M58800100111411 IV-1 0010011141 Hemostasis Adapter IV Spares, Box, Device Count(5) DQX Wire, Guide, Catheter 2 Hemostasis Adapter
21 M58800100600010 ES Siemens 001-006000-1 Stereotaxis Niobe Magnetic Navigation System (MNS) with Navigant Navigation Work Stereotaxis Niobe Magnetic Navigation System (MNS) with Navigant Navigation Workstation. The Niobe MNS with Navigant NWS is intended to navigate compatible magnetic devices through tissue to designated target sites in the right and left heart, coronary vasculature, neurovasculature and peripheral vasculature by orienting the device tip in a desired direction NDQ System, Catheter Or Guidewire, Steerable (Magnetic) 2 Niobe MNS Siemens
22 M5880010017712 1 001-001771-2 The Stereotaxis Cardiodrive is intended for automatically advancing and retracti The Stereotaxis Cardiodrive is intended for automatically advancing and retracting only compatible magnetic electrophysiology (EP) mapping and ablation catheters inside the patient's heart when used in conjunction with a Stereotaxis Magnetic Navigation System (MNS). It is not intended to advance the EP mapping and ablation catheters through the coronary vasculature nor the coronary sinus. DQX Wire, Guide, Catheter Cardiodrive Hemostasis Adapter - SJ
23 M58800101100010 1.1 Siemens 001-011000-1 Genesis MNS is intended to navigate compatible magnetic devices through tissue t Genesis MNS is intended to navigate compatible magnetic devices through tissue to designated target sites in the right andleft heart and coronary vasculature, neurovascular and peripheral vasculature by orienting the device tip in a desireddirection. PJB,NDQ Catheter Remote Control System,System, Catheter Or Guidewire, Steerable (Magnetic) 2 Genesis (MNS) with Siemens
24 M58800101100030 1.1 Model-S 001-011000-3 "Genesis MNS is intended to navigate compatible magnetic devices through tissue "Genesis MNS is intended to navigate compatible magnetic devices through tissue to designated target sites in the right andleft heart and coronary vasculature, neurovascular and peripheral vasculature by orienting the device tip in a desireddirection. " PJB,NDQ Catheter Remote Control System,System, Catheter Or Guidewire, Steerable (Magnetic) 2 Genesis MNS with Model-S
25 M58800100781010 EIF 001-007810-1 The Odyssey Workstation is an optional display and user interface package design The Odyssey Workstation is an optional display and user interface package designed to consolidate the point of control in the Catheter Lab OUG Medical Device Data System 1 Odyssey Enterprise Interface
26 M58800100591011 1 001-005910-1 Stereotaxis Niobe Magnetic Navigation System (MNS) with Navigant Navigation Work Stereotaxis Niobe Magnetic Navigation System (MNS) with Navigant Navigation Workstation. The Niobe MNS with Navigant NWS is intended to navigate compatible magnetic devices through tissue to designated target sites in the right and left heart, coronary vasculature, neurovasculature and peripheral vasculature by orienting the device tip in a desired direction NDQ System, Catheter Or Guidewire, Steerable (Magnetic) Niobe Cover Drape
Other products with the same Product Code "DXX"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 00816280023192 319 319 CorPath GRX Cassette Duo CORINDUS, INC.
2 00816280023123 312 312 CorPath GRX Extended Reach Arm CORINDUS, INC.
3 00816280023116 311 311 CorPath GRX Drape, Control Console CORINDUS, INC.
4 00816280023093 309 309 CorPath GRX Drape, Robotic Drive and Arm CORINDUS, INC.
5 00816280023079 307 307 CorPath GRX Drive Gear CORINDUS, INC.
6 00816280023055 305 305 CorPath GRX Cassette CORINDUS, INC.
7 00816280023031 303 303 CorPath GRX Robotic Drive CORINDUS, INC.
8 00816280023024 302 302 CorPath GRX Extended Reach Arm CORINDUS, INC.
9 00816280023017 301 301 CorPath GRX Control Console CORINDUS, INC.
10 00816280022133 160-00828 160-00828 CorPath 200 Robotic Drive Drape CORINDUS, INC.
11 00816280022119 160-00692 160-00692 CorPath 200 Joystick Covers CORINDUS, INC.
12 00816280022096 160-00981 160-00981 CorPath 200 Control Console Drape CORINDUS, INC.
13 00816280022072 160-00876 160-00876 CorPath 200 POGO Pin Caps CORINDUS, INC.
14 00816280022041 160-00173-NC 160-00173-NC CorPath 200 Cassette CORINDUS, INC.
15 00816280022034 160-00050 160-00050 CorPath 200 Robotic Drive CORINDUS, INC.
16 00816280022027 160-00807 160-00807 CorPath 200 Articulated Arm CORINDUS, INC.
17 00816280022010 160-00043 160-00043 CorPath 200 Control Console CORINDUS, INC.
18 00815671020321 MAR100 MAR100 Magellan Robotic System 120V Magellan™ HANSEN MEDICAL, INC.
19 00815671020314 MTS100 MTS100 Magellan Transport System Magellan™ HANSEN MEDICAL, INC.
20 00815671020284 11132 11132 Magellan Robotic System 120V Magellan™ HANSEN MEDICAL, INC.
21 00815671020260 SRS200 SRS200 Sensei X2 Robotic System 120V Sensei® HANSEN MEDICAL, INC.
22 00815671020246 08257 08257 Sensei X Robotic System Reconditioned 120V Sensei® HANSEN MEDICAL, INC.
23 00815671020215 MAE95 MAE95 Magellan Robotic Catheter eKit Accessory Kit 95cm Magellan™ HANSEN MEDICAL, INC.
24 00815671020208 MAE60 MAE60 Magellan Robotic Catheter eKit Accessory Kit 60cm Magellan™ HANSEN MEDICAL, INC.
25 00815671020147 MA6F95 MA6F95 Magellan Robotic Catheter 6Fr Accessory Kit 95cm Magellan™ HANSEN MEDICAL, INC.
26 00815671020130 MA6F60 MA6F60 Magellan Robotic Catheter 6Fr Accessory Kit 60cm Magellan™ HANSEN MEDICAL, INC.
27 00815671020079 MRCCAD MRCCAD Magellan Robotic Catheter 9Fr & 10Fr Caddy Magellan™ HANSEN MEDICAL, INC.
28 00815671020062 MACC80 MACC80 Magellan Robotic Catheter 9Fr & 10Fr Accessory Kit 80cm Magellan™ HANSEN MEDICAL, INC.
29 00815671020055 MACC65 MACC65 Magellan Robotic Catheter 9Fr & 10Fr Accessory Kit 65cm Magellan™ HANSEN MEDICAL, INC.
30 00815671020048 MACC50 MACC50 Magellan Robotic Catheter 9Fr & 10Fr Accessory Kit 50cm Magellan™ HANSEN MEDICAL, INC.
31 10815671020083 MD6PK MD6PK Magellan Robotic System Sterile Drape Magellan™ HANSEN MEDICAL, INC.
32 10815671020007 06196 06196 Artisan Family Catheter Sterile Drape Artisan® HANSEN MEDICAL, INC.
33 M58800101005611 1 001-010056-1 "The Vdrive® system is intended to stabilize, navigate and remotely control: • C "The Vdrive® system is intended to stabilize, navigate and remotely control: • Compatible Intracardiac Echocardiography (ICE) catheters to facilitate visualization of cardiac structure during theperformance of cardiac procedure when used in conjunction with the V-Sono™ disposable sets in the Vdrive® system, • Compatible loop (circular) mapping catheters to facilitate movement of the catheter during the performance ofelectrophysiological procedures when used in conjunction with the V-Loop™ disposable sets in the Vdrive® system, and • Compatible fixed curve transseptal sheaths and catheters to facilitate movement of the sheath and catheter when usedin conjunction with the V-CAS™ disposable sets in the Vdrive® system and with the Niobe® Magnetic NavigationSystem (MNS). " Vdrive Drape STEREOTAXIS, INC.
34 M58800100701020 Quad HD 001-007010-2 The Odyssey Workstation is an optional display and user interface package design The Odyssey Workstation is an optional display and user interface package designed to consolidate the point of control in the Catheter Lab Odyssey STEREOTAXIS, INC.
35 M58800100246910 1 001-002469-1 Vdrive with V-Sono is indicated for remotely controlling the advancement, retrac Vdrive with V-Sono is indicated for remotely controlling the advancement, retraction, rotation and anterior-posterior deflection of compatible ultrasound catheters inserted into the right atrium V-Sono Intracardiac Echo Manipulator STEREOTAXIS, INC.
36 M58800100245210 1 001-002452-1 The Vdrive with V-Loop disposable is indicated to remotely control the advanceme The Vdrive with V-Loop disposable is indicated to remotely control the advancement, retraction, rotation, tip deflection and loop size of compatibile loop catheters inserted across the septum into the left atrium using conventional procedures V-Loop Variable Loop Catheter Manipulator STEREOTAXIS, INC.
37 M58800100242210 1 001-002422-1 The Vdrive with V-CAS Disposable is indicated for remotely controlling the advan The Vdrive with V-CAS Disposable is indicated for remotely controlling the advancement, retraction, and rotation of compatible magnetic electrophysiology (EP) mapping and ablation catheters inside the patient's heart when used in conjunction with a Stereotaxis Magnetic Navigation System V-CAS Catheter Advancement System STEREOTAXIS, INC.
38 M58800100230720 Duo 001-002307-2 "The Vdrive® system is intended to stabilize, navigate and remotely control: • C "The Vdrive® system is intended to stabilize, navigate and remotely control: • Compatible Intracardiac Echocardiography (ICE) catheters to facilitate visualization of cardiac structure during theperformance of cardiac procedure when used in conjunction with the V-Sono™ disposable sets in the Vdrive® system, • Compatible loop (circular) mapping catheters to facilitate movement of the catheter during the performance ofelectrophysiological procedures when used in conjunction with the V-Loop™ disposable sets in the Vdrive® system, and • Compatible fixed curve transseptal sheaths and catheters to facilitate movement of the sheath and catheter when usedin conjunction with the V-CAS™ disposable sets in the Vdrive® system and with the Niobe® Magnetic NavigationSystem (MNS). " Vdrive System STEREOTAXIS, INC.
39 M58800100230710 Single Arm 001-002307-1 "The Vdrive® system is intended to stabilize, navigate and remotely control: • C "The Vdrive® system is intended to stabilize, navigate and remotely control: • Compatible Intracardiac Echocardiography (ICE) catheters to facilitate visualization of cardiac structure during theperformance of cardiac procedure when used in conjunction with the V-Sono™ disposable sets in the Vdrive® system, • Compatible loop (circular) mapping catheters to facilitate movement of the catheter during the performance ofelectrophysiological procedures when used in conjunction with the V-Loop™ disposable sets in the Vdrive® system, and • Compatible fixed curve transseptal sheaths and catheters to facilitate movement of the sheath and catheter when usedin conjunction with the V-CAS™ disposable sets in the Vdrive® system and with the Niobe® Magnetic NavigationSystem (MNS). " Vdrive System STEREOTAXIS, INC.