Other products from "MEDICAL DESIGNS LLC"
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 M364119902FD90 11-9902-FD9 18mm x 21mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedu 18mm x 21mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation. MAX Intervertebral Fusion Device With Bone Graft, Lumbar 2 Asfora Bullet Cage® System
2 M364119902FD80 11-9902-FD8 16mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedu 16mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation. MAX Intervertebral Fusion Device With Bone Graft, Lumbar 2 Asfora Bullet Cage® System
3 M364119902FD70 11-9902-FD7 16mm x 21mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedu 16mm x 21mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation. MAX Intervertebral Fusion Device With Bone Graft, Lumbar 2 Asfora Bullet Cage® System
4 M364119902FD60 11-9902-FD6 14mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedu 14mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation. MAX Intervertebral Fusion Device With Bone Graft, Lumbar 2 Asfora Bullet Cage® System
5 M364119902FD50 11-9902-FD5 14mm x 21mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedu 14mm x 21mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation. MAX Intervertebral Fusion Device With Bone Graft, Lumbar 2 Asfora Bullet Cage® System
6 M364119902FD40 11-9902-FD4 12mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedu 12mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation. MAX Intervertebral Fusion Device With Bone Graft, Lumbar 2 Asfora Bullet Cage® System
7 M364119902FD30 11-9902-FD3 12mm x 21mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedu 12mm x 21mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation. MAX Intervertebral Fusion Device With Bone Graft, Lumbar 2 Asfora Bullet Cage® System
8 M364119902FD20 11-9902-FD2 10mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedu 10mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation MAX Intervertebral Fusion Device With Bone Graft, Lumbar 2 Asfora Bullet Cage® System
9 M364119902FD100 11-9902-FD10 18mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedu 18mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation. MAX Intervertebral Fusion Device With Bone Graft, Lumbar 2 Asfora Bullet Cage® System
10 M364119902FD10 11-9902-FD1 10mm x 21mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedu 10mm x 21mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation. MAX Intervertebral Fusion Device With Bone Graft, Lumbar Asfora Bullet Cage® System
11 M364111109FD920 11-1109-FD9-2 Adjustable Drill Collar OUR,HWC Sacroiliac Joint Fixation,Screw, Fixation, Bone 2 SAMBA SCREW SYSTEM
12 M364111109FD910 11-1109-FD9-1 Drill Bit OUR,HWC Sacroiliac Joint Fixation,Screw, Fixation, Bone 2 SAMBA SCREW SYSTEM
13 M364111109FD820 11-1109-FD8-2 Packing Tube OUR,HWC Sacroiliac Joint Fixation,Screw, Fixation, Bone 2 SAMBA SCREW SYSTEM
14 M364111109FD810 11-1109-FD8-1 Packing Plunger OUR,HWC Sacroiliac Joint Fixation,Screw, Fixation, Bone 2 SAMBA SCREW SYSTEM
15 M364111109FD730 11-1109-FD7-3 Parallel Guide Sliding Block OUR,HWC Sacroiliac Joint Fixation,Screw, Fixation, Bone 2 SAMBA SCREW SYSTEM
16 M364111109FD720 11-1109-FD7-2 Parallel Guide Locking Nut OUR,HWC Sacroiliac Joint Fixation,Screw, Fixation, Bone 2 SAMBA SCREW SYSTEM
17 M364111109FD710 11-1109-FD7-1 Parallel Guide Frame OUR,HWC Sacroiliac Joint Fixation,Screw, Fixation, Bone 2 SAMBA SCREW SYSTEM
18 M364111109FD211 11-1109-FD21 Long Blunt Steinmann Pin OUR,HWC Sacroiliac Joint Fixation,Screw, Fixation, Bone SAMBA SCREW SYSTEM
19 M364111109FD201 11-1109-FD20 Short Blunt Steinmann Pin OUR,HWC Sacroiliac Joint Fixation,Screw, Fixation, Bone SAMBA SCREW SYSTEM
20 M364111109FD190 11-1109-FD19 Sterilization Case OUR,HWC Sacroiliac Joint Fixation,Screw, Fixation, Bone 2 SAMBA SCREW SYSTEM
21 M364111109FD180 11-1109-FD18 Drill Bit T-Handle OUR,HWC Sacroiliac Joint Fixation,Screw, Fixation, Bone 2 SAMBA SCREW SYSTEM
22 M364111109FD170 11-1109-FD17 Torx Bit T-Handle OUR,HWC Sacroiliac Joint Fixation,Screw, Fixation, Bone 2 SAMBA SCREW SYSTEM
23 M364111109FD161 11-1109-FD16 Sharp Steinmann Pin OUR,HWC Sacroiliac Joint Fixation,Screw, Fixation, Bone SAMBA SCREW SYSTEM
24 M364111109FD150 11-1109-FD15 Plunger Distance Tool OUR,HWC Sacroiliac Joint Fixation,Screw, Fixation, Bone 2 SAMBA SCREW SYSTEM
25 M364111109FD140 11-1109-FD14 Cannulated Torx Driver Bit OUR,HWC Sacroiliac Joint Fixation,Screw, Fixation, Bone 2 SAMBA SCREW SYSTEM
26 M364111109FD130 11-1109-FD13 Striker Tube OUR,HWC Sacroiliac Joint Fixation,Screw, Fixation, Bone 2 SAMBA SCREW SYSTEM
27 M364111109FD110 11-1109-FD11 Pin Sleeve OUR,HWC Sacroiliac Joint Fixation,Screw, Fixation, Bone 2 SAMBA SCREW SYSTEM
28 M364111109FD100 11-1109-FD10 Drill Guide OUR,HWC Sacroiliac Joint Fixation,Screw, Fixation, Bone 2 SAMBA SCREW SYSTEM
29 M111109FD120 11-1109-FD12 Drill Gauge HWC,OUR Screw, Fixation, Bone,Sacroiliac Joint Fixation 2 SAMBA SCREW SYSTEM
30 M364111106FD9160 11-1106-FD9-16 16mm Variable Angle Rescue Screw KWQ Appliance, Fixation, Spinal Intervertebral Body 2 Asfora Anterior Cervical Plate System
31 M364111106FD9140 11-1106-FD9-14 14mm Variable Angle Rescue Screw KWQ Appliance, Fixation, Spinal Intervertebral Body 2 Asfora Anterior Cervical Plate System
32 M364111106FD9120 11-1106-FD9-12 12mm Variable Angle Rescue Screw KWQ Appliance, Fixation, Spinal Intervertebral Body 2 Asfora Anterior Cervical Plate System
33 M364111106FD8160 11-1106-FD8-16 16mm Fixed Angle Locking Screw KWQ Appliance, Fixation, Spinal Intervertebral Body 2 Asfora Anterior Cervical Plate System
34 M364111106FD8140 11-1106-FD8-14 14mm Fixed Angle Locking Screw KWQ Appliance, Fixation, Spinal Intervertebral Body 2 Asfora Anterior Cervical Plate System
35 M364111106FD8120 11-1106-FD8-12 12mm Fixed Angle Locking Screw KWQ Appliance, Fixation, Spinal Intervertebral Body 2 Asfora Anterior Cervical Plate System
36 M364111106FD7160 11-1106-FD7-16 16mm Variable Angle Locking Screw KWQ Appliance, Fixation, Spinal Intervertebral Body 2 Asfora Anterior Cervical Plate System
37 M364111106FD7140 11-1106-FD7-14 14mm Variable Angle Locking Screw KWQ Appliance, Fixation, Spinal Intervertebral Body 2 Asfora Anterior Cervical Plate System
38 M364111106FD7120 11-1106-FD7-12 12mm Variable Angle Locking Screw KWQ Appliance, Fixation, Spinal Intervertebral Body 2 Asfora Anterior Cervical Plate System
39 M364111106FD4940 11-1106-FD4-94 4 Level, 94mm Cervical Plate; The Asfora Anterior Cervical Plate System is inten 4 Level, 94mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporarystabilization to the anterior spine during the development of cervical spinefusions (C2-T1) for the following indications: degenerative disc disease (DDD)(defined as neck pain of discogenic origin with degeneration of the discconfirmed by history and radiographic studies), spondylolisthesis, trauma (i.e.,fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis,kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion. KWQ Appliance, Fixation, Spinal Intervertebral Body 2 Asfora Anterior Cervical Plate System
40 M364111106FD4900 11-1106-FD4-90 4 Level, 90mm Cervical Plate; The Asfora Anterior Cervical Plate System is inten 4 Level, 90mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporarystabilization to the anterior spine during the development of cervical spinefusions (C2-T1) for the following indications: degenerative disc disease (DDD)(defined as neck pain of discogenic origin with degeneration of the discconfirmed by history and radiographic studies), spondylolisthesis, trauma (i.e.,fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis,kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion. KWQ Appliance, Fixation, Spinal Intervertebral Body 2 Asfora Anterior Cervical Plate System
41 M364111106FD4860 11-1106-FD4-86 4 Level, 86mm Cervical Plate; The Asfora Anterior Cervical Plate System is inten 4 Level, 86mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporarystabilization to the anterior spine during the development of cervical spinefusions (C2-T1) for the following indications: degenerative disc disease (DDD)(defined as neck pain of discogenic origin with degeneration of the discconfirmed by history and radiographic studies), spondylolisthesis, trauma (i.e.,fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis,kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion. KWQ Appliance, Fixation, Spinal Intervertebral Body 2 Asfora Anterior Cervical Plate System
42 M364111106FD4820 11-1106-FD4-82 4 Level, 82mm Cervical Plate; The Asfora Anterior Cervical Plate System is inten 4 Level, 82mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporarystabilization to the anterior spine during the development of cervical spinefusions (C2-T1) for the following indications: degenerative disc disease (DDD)(defined as neck pain of discogenic origin with degeneration of the discconfirmed by history and radiographic studies), spondylolisthesis, trauma (i.e.,fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis,kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion. KWQ Appliance, Fixation, Spinal Intervertebral Body 2 Asfora Anterior Cervical Plate System
43 M364111106FD4780 11-1106-FD4-78 4 Level, 78mm Cervical Plate; The Asfora Anterior Cervical Plate System is inten 4 Level, 78mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporarystabilization to the anterior spine during the development of cervical spinefusions (C2-T1) for the following indications: degenerative disc disease (DDD)(defined as neck pain of discogenic origin with degeneration of the discconfirmed by history and radiographic studies), spondylolisthesis, trauma (i.e.,fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis,kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion. KWQ Appliance, Fixation, Spinal Intervertebral Body 2 Asfora Anterior Cervical Plate System
44 M364111106FD4740 11-1106-FD4-74 4 Level, 74mm Cervical Plate; The Asfora Anterior Cervical Plate System is inten 4 Level, 74mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporarystabilization to the anterior spine during the development of cervical spinefusions (C2-T1) for the following indications: degenerative disc disease (DDD)(defined as neck pain of discogenic origin with degeneration of the discconfirmed by history and radiographic studies), spondylolisthesis, trauma (i.e.,fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis,kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion. KWQ Appliance, Fixation, Spinal Intervertebral Body 2 Asfora Anterior Cervical Plate System
45 M364111106FD430 11-1106-FD43 Axial Driver Handle KWQ Appliance, Fixation, Spinal Intervertebral Body 2 Asfora Anterior Cervical Plate System
46 M364111106FD420 11-1106-FD42 Axial Drill Bit Handle KWQ Appliance, Fixation, Spinal Intervertebral Body 2 Asfora Anterior Cervical Plate System
47 M364111106FD410 11-1106-FD41 Fixed Angle Drill Guide KWQ Appliance, Fixation, Spinal Intervertebral Body 2 Asfora Anterior Cervical Plate System
48 M364111106FD3750 11-1106-FD3-75 3 Level, 75mm Cervical Plate; The Asfora Anterior Cervical Plate System is inten 3 Level, 75mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporarystabilization to the anterior spine during the development of cervical spinefusions (C2-T1) for the following indications: degenerative disc disease (DDD)(defined as neck pain of discogenic origin with degeneration of the discconfirmed by history and radiographic studies), spondylolisthesis, trauma (i.e.,fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis,kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion. KWQ Appliance, Fixation, Spinal Intervertebral Body 2 Asfora Anterior Cervical Plate System
49 M364111106FD3720 11-1106-FD3-72 3 Level, 72mm Cervical Plate; The Asfora Anterior Cervical Plate System is inten 3 Level, 72mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporarystabilization to the anterior spine during the development of cervical spinefusions (C2-T1) for the following indications: degenerative disc disease (DDD)(defined as neck pain of discogenic origin with degeneration of the discconfirmed by history and radiographic studies), spondylolisthesis, trauma (i.e.,fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis,kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion. KWQ Appliance, Fixation, Spinal Intervertebral Body 2 Asfora Anterior Cervical Plate System
50 M364111106FD370 11-1106-FD37 Sterilization Case KWQ Appliance, Fixation, Spinal Intervertebral Body 2 Asfora Anterior Cervical Plate System
Other products with the same Product Code "HTW"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 07613154755219 91-23441 91-23441 Drill, WL 40mm, Dental Shaft VARIAX STRYKER TRAUMA SA
2 07613154755196 91-23341 91-23341 Drill, WL 40mm, AO Shaft VARIAX STRYKER TRAUMA SA
3 07613154755189 91-20485 91-20485 Drill, WL 41mm, Dental Shaft End VARIAX STRYKER TRAUMA SA
4 07613154755134 91-19440 91-19440 Drill, WL 41mm, Dental Shaft VARIAX STRYKER TRAUMA SA
5 07613154755042 91-10422 91-10422 Drill, WL 23mm, Dental Shaft PROFYLE STRYKER TRAUMA SA
6 07613154754823 45-35005S 45-35005S Tap for 3.5mm Screws, AO,WL 70mm VARIAX STRYKER TRAUMA SA
7 07613154754809 45-27005S 45-27005S Tap for 2.7mm Screws, AO,WL 50mm VARIAX STRYKER TRAUMA SA
8 07613154730537 92-13006 92-13006 DRILL F. 6MM SCREWS, DENTAL SHAFT NA STRYKER LEIBINGER GMBH & CO. KG
9 07613154583928 92-60190 92-60190 Twist Drill, Twist Length 39mm, AO-Shaft PROFYLE STRYKER TRAUMA SA
10 07613154583904 92-60130 92-60130 Twist Drill, Twist Length 22mm, AO-Shaft PROFYLE STRYKER TRAUMA SA
11 07613154583898 92-60090 92-60090 Twist Drill, Twist Length 22mm, AO-Shaft PROFYLE STRYKER TRAUMA SA
12 07613154583850 60-10322 60-10322 DRILL F. 1.2MM SCREW,WL 22MM,AO,QUICK PROFYLE STRYKER TRAUMA SA
13 07613154567201 3910-004-037 3910-004-037 3.5MM X 24MM XCEL ANCHOR RC DRILL Xcel STRYKER CORPORATION
14 07613154481965 92-00331 92-00331 TROCAR HANDLE WITH SERRATED TROCAR NA STRYKER LEIBINGER GMBH & CO. KG
15 07613154155484 92-19912 92-19912 DRILL F. 12MM SCREWS, DENTAL SHAFT NA STRYKER LEIBINGER GMBH & CO. KG
16 07613154155477 92-16912 92-16912 DRILL F. 12MM SCREWS, DENTAL SHAFT NA STRYKER LEIBINGER GMBH & CO. KG
17 07613154132881 60-88417 60-88417 Bi-Diameter Drill, WL 27.5mm, Dental-Shaft PROFYLE STRYKER TRAUMA SA
18 07613154131822 92-13512 92-13512 DRILL F. 12MM SCREWS, DENTAL SHAFT NA STRYKER LEIBINGER GMBH & CO. KG
19 07613154131815 92-13506 92-13506 DRILL F. 6MM SCREWS, DENTAL SHAFT NA STRYKER LEIBINGER GMBH & CO. KG
20 07613154126804 91-19426 91-19426 Drill, WL 27mm, Dental-Shaft PROFYLE STRYKER TRAUMA SA
21 07613154126798 91-14426 91-14426 Drill, WL 27mm, Dental-Shaft PROFYLE STRYKER TRAUMA SA
22 07613154126781 91-10415 91-10415 Drill, WL 16mm, Dental-Shaft PROFYLE STRYKER TRAUMA SA
23 07613154083299 3910-004-031 3910-004-031 3MM X 24MM XCEL DRILL Xcel STRYKER CORPORATION
24 07613154028238 60-88423 60-88423 Bi-Diameter Drill, WL 27.5mm, Dental-Shaft PROFYLE STRYKER TRAUMA SA
25 07613154028221 60-88412 60-88412 Bi-Diameter Drill, WL 16.5mm, Dental-Shaft PROFYLE STRYKER TRAUMA SA
26 07613154028214 60-88323 60-88323 Bi-Diameter Drill, WL 40mm, AO-Shaft PROFYLE STRYKER TRAUMA SA
27 07613154028207 60-88317 60-88317 Bi-Diameter Drill, WL 27.5mm, AO-Shaft PROFYLE STRYKER TRAUMA SA
28 07613154028191 60-88312 60-88312 Bi-Diameter Drill, WL 16mm, AO-Shaft PROFYLE STRYKER TRAUMA SA
29 07613153173731 92-23126 92-23126 2.3mm Over Drill Bit, WL 26mm, Stryker-Shaft PROFYLE STRYKER TRAUMA SA
30 07613153173458 92-17126 92-17126 1.7mm Over Drill Bit, WL 26mm, Stryker-Shaft PROFYLE STRYKER TRAUMA SA
31 07613153171096 62-32440 62-32440 UNIVERSAL BONE REPOSITIONING INSTRUMENT NA STRYKER LEIBINGER GMBH & CO. KG
32 07613153169352 07-30428 07-30428 Drill Guide For 2.5mm Drill PROFYLE STRYKER TRAUMA SA
33 07613153169345 07-30427 07-30427 Drill Guide For 1.9mm Drill PROFYLE STRYKER TRAUMA SA
34 07613153169338 07-30426 07-30426 Drill Guide For 1.4mm Drill PROFYLE STRYKER TRAUMA SA
35 07613153169321 07-30425 07-30425 Drill Guide For 1.0mm Drill PROFYLE STRYKER TRAUMA SA
36 07613153159957 60-88123 60-88123 Bi-Diameter Drill, WL 27.5mm, Stryker-Shaft PROFYLE STRYKER TRAUMA SA
37 07613153159940 60-88117 60-88117 Bi-Diameter Drill, WL27.5mm, Stryker-Shaft PROFYLE STRYKER TRAUMA SA
38 07613153159933 60-88112 60-88112 Bi-Diameter Drill, WL 16.5mm, Stryker-Shaft PROFYLE STRYKER TRAUMA SA
39 07613153149156 60-10422 60-10422 Drill, WL 23mm, Dental Shaft PROFYLE STRYKER TRAUMA SA
40 07613153149149 60-10122 60-10122 Drill, WL 23mm, Stryker Shaft PROFYLE STRYKER TRAUMA SA
41 07613153149132 60-19140 60-19140 Drill, WL 41mm, Stryker Shaft PROFYLE STRYKER TRAUMA SA
42 07613153068501 60-19440 60-19440 Drill, WL 41mm, Dental Shaft PROFYLE STRYKER TRAUMA SA
43 07611996117738 75100384 75100384 PROMOS REVERSE GLENOID DRILL DIA4 PROMOS SMITH & NEPHEW, INC.
44 07611996087710 75005286 75005286 PROMOS CANNULATED DRILL DIA6.5/3MM PROMOS SMITH & NEPHEW, INC.
45 07540194012791 PEG-CSE100 PEG-CSE100 EMPTY PEG IMPLANT & INSTRUMENT CASE FASSIER-DUVAL TELESCOPIC IM SYSTEM PEGA MEDICAL INC
46 07540194012784 PEG-CEM-28 PEG-CEM-28 EMPTY 2.8mm PEG CADDY FASSIER-DUVAL TELESCOPIC IM SYSTEM PEGA MEDICAL INC
47 07540194012777 PEG-CEM-24 PEG-CEM-24 EMPTY 2.4mm PEG CADDY FASSIER-DUVAL TELESCOPIC IM SYSTEM PEGA MEDICAL INC
48 07540194012760 PEG-CEM-20 PEG-CEM-20 EMPTY 2.0mm PEG CADDY FASSIER-DUVAL TELESCOPIC IM SYSTEM PEGA MEDICAL INC
49 07540194012555 PEG-PGD128 PEG-PGD128 PEG DRILL 2.8 mm FASSIER-DUVAL TELESCOPIC IM SYSTEM PEGA MEDICAL INC
50 07540194012548 PEG-PGD124 PEG-PGD124 PEG DRILL 2.4 mm FASSIER-DUVAL TELESCOPIC IM SYSTEM PEGA MEDICAL INC