No | Primary DI | Version or Model | Catalog Number | Device Description | Product Code | Product Code Name | Device Class | Brand Name |
---|---|---|---|---|---|---|---|---|
1 | M364119902FD90 | 11-9902-FD9 | 18mm x 21mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedu 18mm x 21mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation. | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | Asfora Bullet Cage® System | |
2 | M364119902FD80 | 11-9902-FD8 | 16mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedu 16mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation. | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | Asfora Bullet Cage® System | |
3 | M364119902FD70 | 11-9902-FD7 | 16mm x 21mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedu 16mm x 21mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation. | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | Asfora Bullet Cage® System | |
4 | M364119902FD60 | 11-9902-FD6 | 14mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedu 14mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation. | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | Asfora Bullet Cage® System | |
5 | M364119902FD50 | 11-9902-FD5 | 14mm x 21mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedu 14mm x 21mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation. | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | Asfora Bullet Cage® System | |
6 | M364119902FD40 | 11-9902-FD4 | 12mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedu 12mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation. | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | Asfora Bullet Cage® System | |
7 | M364119902FD30 | 11-9902-FD3 | 12mm x 21mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedu 12mm x 21mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation. | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | Asfora Bullet Cage® System | |
8 | M364119902FD20 | 11-9902-FD2 | 10mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedu 10mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | Asfora Bullet Cage® System | |
9 | M364119902FD100 | 11-9902-FD10 | 18mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedu 18mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation. | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | Asfora Bullet Cage® System | |
10 | M364119902FD10 | 11-9902-FD1 | 10mm x 21mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedu 10mm x 21mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation. | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | Asfora Bullet Cage® System | ||
11 | M364111109FD920 | 11-1109-FD9-2 | Adjustable Drill Collar | OUR,HWC | Sacroiliac Joint Fixation,Screw, Fixation, Bone | 2 | SAMBA SCREW SYSTEM | |
12 | M364111109FD910 | 11-1109-FD9-1 | Drill Bit | OUR,HWC | Sacroiliac Joint Fixation,Screw, Fixation, Bone | 2 | SAMBA SCREW SYSTEM | |
13 | M364111109FD820 | 11-1109-FD8-2 | Packing Tube | OUR,HWC | Sacroiliac Joint Fixation,Screw, Fixation, Bone | 2 | SAMBA SCREW SYSTEM | |
14 | M364111109FD810 | 11-1109-FD8-1 | Packing Plunger | OUR,HWC | Sacroiliac Joint Fixation,Screw, Fixation, Bone | 2 | SAMBA SCREW SYSTEM | |
15 | M364111109FD730 | 11-1109-FD7-3 | Parallel Guide Sliding Block | OUR,HWC | Sacroiliac Joint Fixation,Screw, Fixation, Bone | 2 | SAMBA SCREW SYSTEM | |
16 | M364111109FD720 | 11-1109-FD7-2 | Parallel Guide Locking Nut | OUR,HWC | Sacroiliac Joint Fixation,Screw, Fixation, Bone | 2 | SAMBA SCREW SYSTEM | |
17 | M364111109FD710 | 11-1109-FD7-1 | Parallel Guide Frame | OUR,HWC | Sacroiliac Joint Fixation,Screw, Fixation, Bone | 2 | SAMBA SCREW SYSTEM | |
18 | M364111109FD211 | 11-1109-FD21 | Long Blunt Steinmann Pin | OUR,HWC | Sacroiliac Joint Fixation,Screw, Fixation, Bone | SAMBA SCREW SYSTEM | ||
19 | M364111109FD201 | 11-1109-FD20 | Short Blunt Steinmann Pin | OUR,HWC | Sacroiliac Joint Fixation,Screw, Fixation, Bone | SAMBA SCREW SYSTEM | ||
20 | M364111109FD190 | 11-1109-FD19 | Sterilization Case | OUR,HWC | Sacroiliac Joint Fixation,Screw, Fixation, Bone | 2 | SAMBA SCREW SYSTEM | |
21 | M364111109FD180 | 11-1109-FD18 | Drill Bit T-Handle | OUR,HWC | Sacroiliac Joint Fixation,Screw, Fixation, Bone | 2 | SAMBA SCREW SYSTEM | |
22 | M364111109FD170 | 11-1109-FD17 | Torx Bit T-Handle | OUR,HWC | Sacroiliac Joint Fixation,Screw, Fixation, Bone | 2 | SAMBA SCREW SYSTEM | |
23 | M364111109FD161 | 11-1109-FD16 | Sharp Steinmann Pin | OUR,HWC | Sacroiliac Joint Fixation,Screw, Fixation, Bone | SAMBA SCREW SYSTEM | ||
24 | M364111109FD150 | 11-1109-FD15 | Plunger Distance Tool | OUR,HWC | Sacroiliac Joint Fixation,Screw, Fixation, Bone | 2 | SAMBA SCREW SYSTEM | |
25 | M364111109FD140 | 11-1109-FD14 | Cannulated Torx Driver Bit | OUR,HWC | Sacroiliac Joint Fixation,Screw, Fixation, Bone | 2 | SAMBA SCREW SYSTEM | |
26 | M364111109FD130 | 11-1109-FD13 | Striker Tube | OUR,HWC | Sacroiliac Joint Fixation,Screw, Fixation, Bone | 2 | SAMBA SCREW SYSTEM | |
27 | M364111109FD110 | 11-1109-FD11 | Pin Sleeve | OUR,HWC | Sacroiliac Joint Fixation,Screw, Fixation, Bone | 2 | SAMBA SCREW SYSTEM | |
28 | M364111109FD100 | 11-1109-FD10 | Drill Guide | OUR,HWC | Sacroiliac Joint Fixation,Screw, Fixation, Bone | 2 | SAMBA SCREW SYSTEM | |
29 | M111109FD120 | 11-1109-FD12 | Drill Gauge | HWC,OUR | Screw, Fixation, Bone,Sacroiliac Joint Fixation | 2 | SAMBA SCREW SYSTEM | |
30 | M364111106FD9160 | 11-1106-FD9-16 | 16mm Variable Angle Rescue Screw | KWQ | Appliance, Fixation, Spinal Intervertebral Body | 2 | Asfora Anterior Cervical Plate System | |
31 | M364111106FD9140 | 11-1106-FD9-14 | 14mm Variable Angle Rescue Screw | KWQ | Appliance, Fixation, Spinal Intervertebral Body | 2 | Asfora Anterior Cervical Plate System | |
32 | M364111106FD9120 | 11-1106-FD9-12 | 12mm Variable Angle Rescue Screw | KWQ | Appliance, Fixation, Spinal Intervertebral Body | 2 | Asfora Anterior Cervical Plate System | |
33 | M364111106FD8160 | 11-1106-FD8-16 | 16mm Fixed Angle Locking Screw | KWQ | Appliance, Fixation, Spinal Intervertebral Body | 2 | Asfora Anterior Cervical Plate System | |
34 | M364111106FD8140 | 11-1106-FD8-14 | 14mm Fixed Angle Locking Screw | KWQ | Appliance, Fixation, Spinal Intervertebral Body | 2 | Asfora Anterior Cervical Plate System | |
35 | M364111106FD8120 | 11-1106-FD8-12 | 12mm Fixed Angle Locking Screw | KWQ | Appliance, Fixation, Spinal Intervertebral Body | 2 | Asfora Anterior Cervical Plate System | |
36 | M364111106FD7160 | 11-1106-FD7-16 | 16mm Variable Angle Locking Screw | KWQ | Appliance, Fixation, Spinal Intervertebral Body | 2 | Asfora Anterior Cervical Plate System | |
37 | M364111106FD7140 | 11-1106-FD7-14 | 14mm Variable Angle Locking Screw | KWQ | Appliance, Fixation, Spinal Intervertebral Body | 2 | Asfora Anterior Cervical Plate System | |
38 | M364111106FD7120 | 11-1106-FD7-12 | 12mm Variable Angle Locking Screw | KWQ | Appliance, Fixation, Spinal Intervertebral Body | 2 | Asfora Anterior Cervical Plate System | |
39 | M364111106FD4940 | 11-1106-FD4-94 | 4 Level, 94mm Cervical Plate; The Asfora Anterior Cervical Plate System is inten 4 Level, 94mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporarystabilization to the anterior spine during the development of cervical spinefusions (C2-T1) for the following indications: degenerative disc disease (DDD)(defined as neck pain of discogenic origin with degeneration of the discconfirmed by history and radiographic studies), spondylolisthesis, trauma (i.e.,fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis,kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion. | KWQ | Appliance, Fixation, Spinal Intervertebral Body | 2 | Asfora Anterior Cervical Plate System | |
40 | M364111106FD4900 | 11-1106-FD4-90 | 4 Level, 90mm Cervical Plate; The Asfora Anterior Cervical Plate System is inten 4 Level, 90mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporarystabilization to the anterior spine during the development of cervical spinefusions (C2-T1) for the following indications: degenerative disc disease (DDD)(defined as neck pain of discogenic origin with degeneration of the discconfirmed by history and radiographic studies), spondylolisthesis, trauma (i.e.,fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis,kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion. | KWQ | Appliance, Fixation, Spinal Intervertebral Body | 2 | Asfora Anterior Cervical Plate System | |
41 | M364111106FD4860 | 11-1106-FD4-86 | 4 Level, 86mm Cervical Plate; The Asfora Anterior Cervical Plate System is inten 4 Level, 86mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporarystabilization to the anterior spine during the development of cervical spinefusions (C2-T1) for the following indications: degenerative disc disease (DDD)(defined as neck pain of discogenic origin with degeneration of the discconfirmed by history and radiographic studies), spondylolisthesis, trauma (i.e.,fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis,kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion. | KWQ | Appliance, Fixation, Spinal Intervertebral Body | 2 | Asfora Anterior Cervical Plate System | |
42 | M364111106FD4820 | 11-1106-FD4-82 | 4 Level, 82mm Cervical Plate; The Asfora Anterior Cervical Plate System is inten 4 Level, 82mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporarystabilization to the anterior spine during the development of cervical spinefusions (C2-T1) for the following indications: degenerative disc disease (DDD)(defined as neck pain of discogenic origin with degeneration of the discconfirmed by history and radiographic studies), spondylolisthesis, trauma (i.e.,fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis,kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion. | KWQ | Appliance, Fixation, Spinal Intervertebral Body | 2 | Asfora Anterior Cervical Plate System | |
43 | M364111106FD4780 | 11-1106-FD4-78 | 4 Level, 78mm Cervical Plate; The Asfora Anterior Cervical Plate System is inten 4 Level, 78mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporarystabilization to the anterior spine during the development of cervical spinefusions (C2-T1) for the following indications: degenerative disc disease (DDD)(defined as neck pain of discogenic origin with degeneration of the discconfirmed by history and radiographic studies), spondylolisthesis, trauma (i.e.,fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis,kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion. | KWQ | Appliance, Fixation, Spinal Intervertebral Body | 2 | Asfora Anterior Cervical Plate System | |
44 | M364111106FD4740 | 11-1106-FD4-74 | 4 Level, 74mm Cervical Plate; The Asfora Anterior Cervical Plate System is inten 4 Level, 74mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporarystabilization to the anterior spine during the development of cervical spinefusions (C2-T1) for the following indications: degenerative disc disease (DDD)(defined as neck pain of discogenic origin with degeneration of the discconfirmed by history and radiographic studies), spondylolisthesis, trauma (i.e.,fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis,kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion. | KWQ | Appliance, Fixation, Spinal Intervertebral Body | 2 | Asfora Anterior Cervical Plate System | |
45 | M364111106FD430 | 11-1106-FD43 | Axial Driver Handle | KWQ | Appliance, Fixation, Spinal Intervertebral Body | 2 | Asfora Anterior Cervical Plate System | |
46 | M364111106FD420 | 11-1106-FD42 | Axial Drill Bit Handle | KWQ | Appliance, Fixation, Spinal Intervertebral Body | 2 | Asfora Anterior Cervical Plate System | |
47 | M364111106FD410 | 11-1106-FD41 | Fixed Angle Drill Guide | KWQ | Appliance, Fixation, Spinal Intervertebral Body | 2 | Asfora Anterior Cervical Plate System | |
48 | M364111106FD3750 | 11-1106-FD3-75 | 3 Level, 75mm Cervical Plate; The Asfora Anterior Cervical Plate System is inten 3 Level, 75mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporarystabilization to the anterior spine during the development of cervical spinefusions (C2-T1) for the following indications: degenerative disc disease (DDD)(defined as neck pain of discogenic origin with degeneration of the discconfirmed by history and radiographic studies), spondylolisthesis, trauma (i.e.,fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis,kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion. | KWQ | Appliance, Fixation, Spinal Intervertebral Body | 2 | Asfora Anterior Cervical Plate System | |
49 | M364111106FD3720 | 11-1106-FD3-72 | 3 Level, 72mm Cervical Plate; The Asfora Anterior Cervical Plate System is inten 3 Level, 72mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporarystabilization to the anterior spine during the development of cervical spinefusions (C2-T1) for the following indications: degenerative disc disease (DDD)(defined as neck pain of discogenic origin with degeneration of the discconfirmed by history and radiographic studies), spondylolisthesis, trauma (i.e.,fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis,kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion. | KWQ | Appliance, Fixation, Spinal Intervertebral Body | 2 | Asfora Anterior Cervical Plate System | |
50 | M364111106FD370 | 11-1106-FD37 | Sterilization Case | KWQ | Appliance, Fixation, Spinal Intervertebral Body | 2 | Asfora Anterior Cervical Plate System |
No | Primary DI | Version or Model | Catalog Number | Device Description | Brand Name | Organization Name |
---|---|---|---|---|---|---|
1 | 00819824025126 | 67000003 | 67000003 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR ACP SYSTEM - TRAYS | MET 1 TECHNOLOGIES, LLC |
2 | 00819824025119 | 67000002 | 67000002 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR ACP SYSTEM - PLATE CADDIE | MET 1 TECHNOLOGIES, LLC |
3 | 00819824025102 | 67000001 | 67000001 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR ACP SYSTEM - SCREW CADDIE | MET 1 TECHNOLOGIES, LLC |
4 | 00819824025096 | 66000018 | 66000018 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR ACP SYSTEM - DRILL 18 MM | MET 1 TECHNOLOGIES, LLC |
5 | 00819824025089 | 66000016 | 66000016 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR ACP SYSTEM - DRILL 16 MM | MET 1 TECHNOLOGIES, LLC |
6 | 00819824025072 | 66000014 | 66000014 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR ACP SYSTEM - DRILL 14 MM | MET 1 TECHNOLOGIES, LLC |
7 | 00819824025065 | 66000012 | 66000012 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR ACP SYSTEM - DRILL 12 MM | MET 1 TECHNOLOGIES, LLC |
8 | 00819824025058 | 66000010 | 66000010 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR ACP SYSTEM - DRILL 10 MM | MET 1 TECHNOLOGIES, LLC |
9 | 00819824025041 | 66000009 | 66000009 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR ACP SYSTEM - SCREW REMOVAL DRAW ROD | MET 1 TECHNOLOGIES, LLC |
10 | 00819824025034 | 66000008 | 66000008 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR ACP SYSTEM - SCREW REMOVAL DRIVER | MET 1 TECHNOLOGIES, LLC |
11 | 00819824025027 | 66000007 | 66000007 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR ACP SYSTEM - SCREW REMOVAL TUBE | MET 1 TECHNOLOGIES, LLC |
12 | 00819824025010 | 66000006 | 66000006 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR ACP SYSTEM - INSERTION TACK | MET 1 TECHNOLOGIES, LLC |
13 | 00819824025003 | 66000005 | 66000005 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR ACP SYSTEM - SCREW INSERTER - SCREW ON | MET 1 TECHNOLOGIES, LLC |
14 | 00819824024990 | 66000021 | 66000021 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR ACP SYSTEM - SCREW INSERTER - STAB & GRAB | MET 1 TECHNOLOGIES, LLC |
15 | 00819824024983 | 66000004 | 66000004 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR ACP SYSTEM - SINGLE BARREL DRILL GUIDE VARIABLE | MET 1 TECHNOLOGIES, LLC |
16 | 00819824024976 | 66000003 | 66000003 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR ACP SYSTEM - DOUBLE BARREL DRILL GUIDE FIXED | MET 1 TECHNOLOGIES, LLC |
17 | 00819824024969 | 66000002 | 66000002 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR ACP SYSTEM - ALL IN 1 DOUBLE DRILL GUIDE VARIABLE | MET 1 TECHNOLOGIES, LLC |
18 | 00819824024952 | 66000001 | 66000001 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR ACP SYSTEM - ALL IN 1 SINGLE DRILL GUIDE VARIABLE | MET 1 TECHNOLOGIES, LLC |
19 | 00819824024945 | 65000005 | 65000005 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR ACP SYSTEM - AWL | MET 1 TECHNOLOGIES, LLC |
20 | 00819824024938 | 65000004 | 65000004 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR ACP SYSTEM - RATCHETING AO HANDLE | MET 1 TECHNOLOGIES, LLC |
21 | 00819824024921 | 65000003 | 65000003 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR ACP SYSTEM - PLATE BENDER | MET 1 TECHNOLOGIES, LLC |
22 | 00819824024914 | 65000002 | 65000002 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR ACP SYSTEM - CALIPER | MET 1 TECHNOLOGIES, LLC |
23 | 00819824024907 | 65000001 | 65000001 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR ACP SYSTEM - PLATE HOLDER | MET 1 TECHNOLOGIES, LLC |
24 | 00819824024891 | 64510118 | 64510118 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR FIXED SELF TAPPING SCREW 4.5 | MET 1 TECHNOLOGIES, LLC |
25 | 00819824024884 | 64510116 | 64510116 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR FIXED SELF TAPPING SCREW 4.5 | MET 1 TECHNOLOGIES, LLC |
26 | 00819824024877 | 64510114 | 64510114 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR FIXED SELF TAPPING SCREW 4.5 | MET 1 TECHNOLOGIES, LLC |
27 | 00819824024860 | 64510112 | 64510112 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR FIXED SELF TAPPING SCREW 4.5 | MET 1 TECHNOLOGIES, LLC |
28 | 00819824024853 | 64510110 | 64510110 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR FIXED SELF TAPPING SCREW 4.5 | MET 1 TECHNOLOGIES, LLC |
29 | 00819824024846 | 64010118 | 64010118 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR FIXED SELF TAPPING SCREW 4.0 | MET 1 TECHNOLOGIES, LLC |
30 | 00819824024839 | 64010116 | 64010116 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR FIXED SELF TAPPING SCREW 4.0 | MET 1 TECHNOLOGIES, LLC |
31 | 00819824024822 | 64010114 | 64010114 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR FIXED SELF TAPPING SCREW 4.0 | MET 1 TECHNOLOGIES, LLC |
32 | 00819824024815 | 64010112 | 64010112 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR FIXED SELF TAPPING SCREW 4.0 | MET 1 TECHNOLOGIES, LLC |
33 | 00819824024808 | 64010110 | 64010110 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR FIXED SELF TAPPING SCREW 4.0 | MET 1 TECHNOLOGIES, LLC |
34 | 00819824024792 | 64510018 | 64510018 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR VARIABLE SELF TAPPING SCREW 4.5 | MET 1 TECHNOLOGIES, LLC |
35 | 00819824024785 | 64510016 | 64510016 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR VARIABLE SELF TAPPING SCREW 4.5 | MET 1 TECHNOLOGIES, LLC |
36 | 00819824024778 | 64510014 | 64510014 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR VARIABLE SELF TAPPING SCREW 4.5 | MET 1 TECHNOLOGIES, LLC |
37 | 00819824024761 | 64510012 | 64510012 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR VARIABLE SELF TAPPING SCREW 4.5 | MET 1 TECHNOLOGIES, LLC |
38 | 00819824024754 | 64510010 | 64510010 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR VARIABLE SELF TAPPING SCREW 4.5 | MET 1 TECHNOLOGIES, LLC |
39 | 00819824024747 | 64010018 | 64010018 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR VARIABLE SELF TAPPING SCREW 4.0 | MET 1 TECHNOLOGIES, LLC |
40 | 00819824024730 | 64010016 | 64010016 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR VARIABLE SELF TAPPING SCREW 4.0 | MET 1 TECHNOLOGIES, LLC |
41 | 00819824024723 | 64010014 | 64010014 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR VARIABLE SELF TAPPING SCREW 4.0 | MET 1 TECHNOLOGIES, LLC |
42 | 00819824024716 | 64010012 | 64010012 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR VARIABLE SELF TAPPING SCREW 4.0 | MET 1 TECHNOLOGIES, LLC |
43 | 00819824024709 | 64010010 | 64010010 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR VARIABLE SELF TAPPING SCREW 4.0 | MET 1 TECHNOLOGIES, LLC |
44 | 00819824024693 | 64500118 | 64500118 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR FIXED SELF DRILLING SCREW 4.5 | MET 1 TECHNOLOGIES, LLC |
45 | 00819824024686 | 64500116 | 64500116 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR FIXED SELF DRILLING SCREW 4.5 | MET 1 TECHNOLOGIES, LLC |
46 | 00819824024679 | 64500114 | 64500114 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR FIXED SELF DRILLING SCREW 4.5 | MET 1 TECHNOLOGIES, LLC |
47 | 00819824024662 | 64500112 | 64500112 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR FIXED SELF DRILLING SCREW 4.5 | MET 1 TECHNOLOGIES, LLC |
48 | 00819824024655 | 64500110 | 64500110 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR FIXED SELF DRILLING SCREW 4.5 | MET 1 TECHNOLOGIES, LLC |
49 | 00819824024648 | 64000118 | 64000118 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR FIXED SELF DRILLING SCREW 4.0 | MET 1 TECHNOLOGIES, LLC |
50 | 00819824024631 | 64000116 | 64000116 | THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBO THE MET ONE CZAR ANTERIOR CERVICAL PLATE SYSTEM IS INTENDED FOR ANTERIOR INTERBODY SCREW FIXATION OF THE CERVICAL SPINE. THE SYSTEM INCLUDES SCREWS, PLATES, AND A SET OF INSTRUMENTS TO INSERT THE IMPLANTS. PLATES ARE AVAILABLE IN A VARIETY OF LENGTHS TO ACCOMODATE FUSION PROCEDURES FROM ONE TO FOUR LEVELS OF THE CERVICAL SPINE. FIXATION IS ACHIEVED BY INSERTING THE SCREWS THROUGH THE OPENINGS IN THE PLATE INTO VERTEBRAL BODIES OF THE CERVICAL SPINE. THE PLATES ARE MANUFACTURED FROM TITANIUM 6 A1-4V ELI PER ASTM F136 AND INVIBIO PEEK-OPTIMA LT1 PER ASTM F2026. | CZAR FIXED SELF DRILLING SCREW 4.0 | MET 1 TECHNOLOGIES, LLC |