No | Primary DI | Version or Model | Catalog Number | Device Description | Product Code | Product Code Name | Device Class | Brand Name |
---|---|---|---|---|---|---|---|---|
1 | M266EC22000 | EC2200 | The Whitney Medical Solutions’ eShield consists of polyethylene film (and an adh The Whitney Medical Solutions’ eShield consists of polyethylene film (and an adhesive pad in some models) with tear guide tape and a zipper that allows thecover to be torn fairly straight across it. There is also a double sided tape below the zipper that is used as a redundant closure method with the cover beingfolded twice and sealed against it. The device is provided to the user sterile, is labeled for single use only and not intended for resterilization or reprocessing. The sterile eShield is sterilized using a validated irradiation sterilization method. | KKX | Drape, Surgical | 2 | eShield Digital Camera Size | |
2 | M266EC23000 | EC2300 | The Whitney Medical Solutions’ eShield consists of polyethylene film (and an adh The Whitney Medical Solutions’ eShield consists of polyethylene film (and an adhesive pad in some models) with tear guide tape and a zipper that allows thecover to be torn fairly straight across it. There is also a double sided tape below the zipper that is used as a redundant closure method with the cover beingfolded twice and sealed against it. The device is provided to the user sterile, is labeled for single use only and not intended for resterilization or reprocessing.The sterile eShield is sterilized using a validated irradiation sterilization method. | KKX | Drape, Surgical | 2 | eShield Tablet Size | |
3 | M266EC21000 | EC2100 | The Whitney Medical Solutions’ eShield consists of polyethylene film (and an adh The Whitney Medical Solutions’ eShield consists of polyethylene film (and an adhesive pad in some models) with tear guide tape and a zipper that allows thecover to be torn fairly straight across it. There is also a double sided tape below the zipper that is used as a redundant closure method with the cover being folded twice and sealed against it. The device is provided to the user sterile, is labeled for single use only and not intended for resterilization or reprocessing.The sterile eShield is sterilized using a validated irradiation sterilization method. | KKX | Drape, Surgical | 2 | eShield Cell Phone Size | |
4 | M266OR12020 | OR1202 | OR1202 | No-Scratch ™ Large Whitney Curette ™ is a single-use, plastic curette for quickl No-Scratch ™ Large Whitney Curette ™ is a single-use, plastic curette for quickly applying, manipulating and removing bone cement during hip and knee replacement surgery. The plastic is softer than steel instruments, reducing the risk of damaging the prosthesis with metal instruments. The large curette’s 20mm tip removes excess cement from replacement hips and knees. Easy-to-maneuver, the large yellow curette lets you remove cement from all edges of the prosthesis.No-Scratch Large Whitney Curette Features:SAFER THAN STEEL- Made of plastic - sturdy yet softer than surgical steel.HANDIER- Each tool has a molded-in thumb indentation instantly orienting the tool.- Easier to maneuver in hard to see places.- Color-coded for easy identification.FASTER- Comes individually packaged in sterile, peel open pouch, ready to go.- Applies, manipulates, or removes cement with fingertip precision.ECONOMICAL- The cost of a single revision dwarfs the cost of a single-use curette. - Disposable – there’s no need to waste time removing hardened cement or re-sterilizing tools.- Less expensive to buy and inventory - order only the tool you use.- Packaged 25 individually wrapped tools to a carton for convenient shelf storage. | LXH | Orthopedic Manual Surgical Instrument | 1 | Whitney No-Scratch Curette (Large) |
5 | M266OR12010 | OR1201 | OR1201 | No-Scratch ™ Small Whitney Curette ™ is a single-use, plastic curette for quickl No-Scratch ™ Small Whitney Curette ™ is a single-use, plastic curette for quickly applying, manipulating and removing bone cement during hip and knee replacement surgery. The plastic is softer than steel instruments, reducing the risk of damaging the prosthesis with metal instruments. The curette’s 6mm tip removes excess cement from replacement hips and knees. Easy-to-maneuver, the small blue curette lets you remove cement from all edges of the prosthesis.No-Scratch Whitney Small Curette Features:SAFER THAN STEEL- Made of plastic - sturdy yet softer than surgical steel.HANDIER- Each tool has a molded-in thumb indentation instantly orienting the tool.- Easier to maneuver in hard to see places.- Color-coded for easy identification.FASTER- Comes individually packaged in sterile, peel open pouch, ready to go.- Applies, manipulates, or removes cement with fingertip precision.ECONOMICAL- The cost of a single revision dwarfs the cost of a single-use curette. - Disposable – there’s no need to waste time removing hardened cement or re-sterilizing tools.- Less expensive to buy and inventory - order only the tool you use.- Packaged 25 individually wrapped tools to a carton for convenient shelf storage. | LXH | Orthopedic Manual Surgical Instrument | 1 | Whitney No-Scratch Curette (Small) |
6 | M266OR12050 | OR1205 | OR1205 | No-Scratch ™ Whitney Valitome ™ is a single-use, sterile, plastic instrument, in No-Scratch ™ Whitney Valitome ™ is a single-use, sterile, plastic instrument, in the shape of an osteotome, for quickly applying, manipulating, spreading, and removing bone cement during hip and knee replacement surgery. The plastic is softer than steel instruments, reducing the risk of damaging the prosthesis with metal instruments. The Valitome’s 12mm wide tip removes excess cement from replacement hips and knees, and can also be used to apply or spread cement. Easy-to-maneuver, the teal Valitome lets you remove cement from all edges of the prosthesis.No-Scratch Whitney Valitome Features:SAFER THAN STEEL- Made of plastic - sturdy yet softer than surgical steel.HANDIER- Each tool has a molded-in thumb indentation instantly orienting the tool.- Easier to maneuver in hard to see places.- Color-coded for easy identification.FASTER- Comes individually packaged in sterile, peel open pouch, ready to go.- Applies, manipulates, or removes cement with fingertip precision.ECONOMICAL- The cost of a single revision dwarfs the cost of a single-use instrument. - Disposable – there’s no need to waste time removing hardened cement or re-sterilizing tools.- Less expensive to buy and inventory - order only the tool you use.- Packaged 25 individually wrapped tools to a carton for convenient shelf storage. | LXH | Orthopedic Manual Surgical Instrument | 1 | Whitney No-Scratch Valitome |
7 | M266EC24000 | EC2400 | The Whitney Medical Solutions’ eShield consists of polyethylene film (and an adh The Whitney Medical Solutions’ eShield consists of polyethylene film (and an adhesive pad in some models) with tear guide tape and a zipper that allows thecover to be torn fairly straight across it. There is also a double sided tape below the zipper that is used as a redundant closure method with the cover beingfolded twice and sealed against it. The device is provided to the user sterile, is labeled for single use only and not intended for resterilization or reprocessing.The sterile eShield is sterilized using a validated irradiation sterilization method. | KKX | Drape, Surgical | 2 | eShield SLR Camera Size |
No | Primary DI | Version or Model | Catalog Number | Device Description | Brand Name | Organization Name |
---|---|---|---|---|---|---|
1 | B267110023750 | 110-02-375 | 110-02-375 | 3.6 mm Flow-Drill Guide | Flow-Drill™ | FLOW-FX |
2 | B267110010 | 110-01 | 110-01 | Ratchet Handle | Flow-Drill™ | FLOW-FX |
3 | B26710281650 | 102-81-65 | 102-81-65 | FS 6.5/7/3mm Short IO Adapter | Flow-Screw™ | FLOW-FX |
4 | B26710281450 | 102-81-45 | 102-81-45 | FS 3.5/4.5mm Short IO Adapter | Flow-Screw™ | FLOW-FX |
5 | B26710280650 | 102-80-65 | 102-80-65 | FS IO Adapter Long 6.5MM | Flow-Screw™ | FLOW-FX |
6 | B26710280550 | 102-80-55 | 102-80-55 | FS IO Adapter Long 5.5MM | Flow-Screw™ | FLOW-FX |
7 | B26710280450 | 102-80-45 | 102-80-45 | FS IO Adapter Long 4.5MM | Flow-Screw™ | FLOW-FX |
8 | B2671025102D0 | 102-51-02D | 102-51-02D | Plunger, 6.5/7/3 Screw | Flow-Screw™ | FLOW-FX |
9 | B26710251020 | 102-51-02 | 102-51-02 | FS 6.5/7.3mm SPC Plunger | Flow-Screw™ | FLOW-FX |
10 | B2671025101D0 | 102-51-01D | 102-51-01D | Plunger, 5.5 mm Screw | Flow-Screw™ | FLOW-FX |
11 | B26710251010 | 102-51-01 | 102-51-01 | FS SPC Plunger 5.5mm | Flow-Screw™ | FLOW-FX |
12 | B26710213010 | 102-13-01 | 102-13-01 | FS Length Gauge 5.5mm | Flow-Screw™ | FLOW-FX |
13 | B26710213000 | 102-13-00 | 102-13-00 | FS Length Gauge 4.5mm | Flow-Screw™ | FLOW-FX |
14 | B267102080 | 102-08 | 102-08 | FS Bisek/Hudson Adapter | Flow-Screw™ | FLOW-FX |
15 | B26710172D0 | 101-72D | 101-72D | FN Plunger, Single Use | Flow-Nail™ | FLOW-FX |
16 | B26710101K0 | 101-01K | 101-01K | T-Handle, Keyed | Flow-Nail™ | FLOW-FX |
17 | B1830870000220 | Panama™ | 08-7000-022 | Screw Retaining Sleeve | Panama™ | FLOSPINE LLC |
18 | B1830870000200 | Panama™ | 08-7000-020 | AO Pull-Connect Ratchet Handle | Panama™ | FLOSPINE LLC |
19 | B1830870000150 | Panama™ | 08-7000-015 | Variable-Angle Drill Guide | Panama™ | FLOSPINE LLC |
20 | B1830870000140 | Panama™ | 08-7000-014 | Fixed-Angle Drill Guide | Panama™ | FLOSPINE LLC |
21 | B1830870000130 | Panama™ | 08-7000-013 | Temporary Fixation Pin Holder | Panama™ | FLOSPINE LLC |
22 | B1830870000120 | Panama™ | 08-7000-012 | Temporary Fixation Pin | Panama™ | FLOSPINE LLC |
23 | B1830870000110 | Panama™ | 08-7000-011 | Cervical Plate Holder | Panama™ | FLOSPINE LLC |
24 | B1830870000100 | Panama™ | 08-70000-010 | AO Pull-Connect Handle | Panama™ | FLOSPINE LLC |
25 | B14211000100010 | 1100-01-0001 | Inserter Retention | Cohere | VERTERA, INC. | |
26 | B14211000000160 | 1100-00-0016 | Inserter Body, 14x16, Cohere Interbody Fusion Device | Cohere | VERTERA, INC. | |
27 | B14211000000140 | 1100-00-0014 | Inserter Body, 12x14, Cohere Interbody Fusion Device | Cohere | VERTERA, INC. | |
28 | B14211000000010 | 1100-00-0001 | Inserter Body, Cohere Interbody Fusion Device | Cohere | VERTERA, INC. | |
29 | B114310150 | 15mm Straight | 310-15 | Trial for 15mm straight lumbar inter-vertebral body spacer | Lumbar Interbody Spacer Trial | CALVARY SPINE, LLC |
30 | B114310140 | 14mm Straight | 310-14 | Trial for 14mm straight lumbar inter-vertebral body spacer | Lumbar Interbody Spacer Trial | CALVARY SPINE, LLC |
31 | B114310130 | 13mm Straight | 310-13 | Trial for 13mm straight lumbar inter-vertebral body spacer | Lumbar Interbody Spacer Trial | CALVARY SPINE, LLC |
32 | B114310120 | 12mm Straight | 310-12 | Trial for 12mm straight lumbar inter-vertebral body spacer | Lumbar Interbody Spacer Trial | CALVARY SPINE, LLC |
33 | B114310110 | 11mm Straight | 310-11 | Trial for 11mm straight lumbar inter-vertebral body spacer | Lumbar Interbody Spacer Trial | CALVARY SPINE, LLC |
34 | B114310100 | 10mm Straight | 310-10 | Trial for 10mm straight lumbar inter-vertebral body spacer | Lumbar Interbody Spacer Trial | CALVARY SPINE, LLC |
35 | B114310090 | 9mm Straight | 310-09 | Trial for 9mm straight lumbar inter-vertebral body spacer | Lumbar Interbody Spacer Trial | CALVARY SPINE, LLC |
36 | B114310080 | 8mm Straight | 310-08 | Trial for 8mm straight lumbar inter-vertebral body spacer | Lumbar Interbody Spacer Trial | CALVARY SPINE, LLC |
37 | B114310070 | 7mm Straight | 310-07 | Trial for 7mm straight lumbar inter-vertebral body spacer | Lumbar Interbody Spacer Trial | CALVARY SPINE, LLC |
38 | B114285010 | Cervical Instrument Tray | 285-01 | Sterilization container for Calvary Cervical instruments | Cervical Instrument Tray | CALVARY SPINE, LLC |
39 | B114280010 | Cervical Implant Caddy | 280-01 | Sterilization container for Calvary Cervical implants | Cervical Implant Caddy | CALVARY SPINE, LLC |
40 | B114215000 | Cervical Double sidedRasp | 215-00 | Bone Rasp used for site prep for cervical inter-vertebral body spacers | Cervical Double Sided Rasp | CALVARY SPINE, LLC |
41 | B114214000 | Mallet | 214-00 | Mallet used for cervical inter-vertebral body spacer placement | Mallet | CALVARY SPINE, LLC |
42 | B114213000 | Cervical Spacer Inserter | 213-00 | Inserter used for cervical inter-vertebral body spacer placement | Cervical Spacer Inserter | CALVARY SPINE, LLC |
43 | B114212000 | Cervical Tamp | 212-00 | Tamp used for cervical inter-vertebral body spacer placement | Cervical Tamp | CALVARY SPINE, LLC |
44 | B114211090 | 9mm Dual Head Trial | 211-09 | Dual Head Trial for 9mm standard and large cervical inter-vertebral body spacers | Cervical Interbody Spacer Trial | CALVARY SPINE, LLC |
45 | B114211080 | 8mm Dual Head Trial | 211-08 | Dual Head Trial for 8mm standard and large cervical inter-vertebral body spacers | Cervical Interbody Spacer Trial | CALVARY SPINE, LLC |
46 | B114211070 | 7mm Dual Head Trial | 211-07 | Dual Head Trial for 7mm standard and large cervical inter-vertebral body spacers | Cervical Interbody Spacer Trial | CALVARY SPINE, LLC |
47 | B114211060 | 6mm Dual Head Trial | 211-06 | Dual Head Trial for 6mm standard and large cervical inter-vertebral body spacers | Cervical Interbody Spacer Trial | CALVARY SPINE, LLC |
48 | B114211050 | 5mm Dual Head Trial | 211-05 | Dual Head Trial for 5mm standard and large cervical inter-vertebral body spacers | Cervical Interbody Spacer Trial | CALVARY SPINE, LLC |
49 | B114211000 | Cervical Rasp | 211-00 | Bone Rasp used for site prep for cervical inter-vertebral body spacers | Cervical Rasp | CALVARY SPINE, LLC |
50 | B114210090 | 9mm Trial | 210-09 | Trial for 9mm standard cervical inter-vertebral body spacer | Cervical Interbody Spacer Trial | CALVARY SPINE, LLC |