Duns Number:008999906
Device Description: Each Vascular Solutions D-Stat® flowable hemostat (D-Stat) includes the following componen Each Vascular Solutions D-Stat® flowable hemostat (D-Stat) includes the following components: Thrombin vial (5,000 units); Collagen (200mg), contained in 10ml syringe with attached mixing luer; Diluent vial (5ml); Mixing accessories (10ml syringe and needleless, non-coring vial access device); Applicator tips: (1) small bore tip, (1) 20-Gauge, 2.75" needle.The thrombin is a protein substance produced through a conversion reaction in which prothrombin of bovine origin is activated by tissue thromboplastin of bovine-origin in the presence of calcium chloride. It is supplied as a sterile powder that has been freeze-dried in the final container. Also contained in the thrombin vial are mannitol and sodium chloride. Mannitol is included to make the dried product friable and more readily soluble. The material contains no preservative and has been chromatographically purified. Thrombin requires no intermediate physiological agent for its reaction. It converts fibrinogen directly to fibrin.The collagen is a soft, white, pliable, absorbent hemostatic agent derived from purified bovine deep flexor tendon. It is prepared in a loose fibrous form. Collagen attracts platelets that adhere to the fibrils and undergo the release phenomenon to trigger aggregation of platelets into thrombi in the interstices of the fibrous mass. The collagen provides a three-dimensional matrix for additional strengthening of the clot. The effect on platelet adhesion and aggregation is not inhibited by heparin in vitro.The diluent is a sterile solution of calcium chloride and water, buffered with tromethamine (TRIS). Using the mixing accessories, both the thrombin and collagen are reconstituted with the diluent prior to use. The hemostat is delivered to the intended treatment site using the provided applicator tips. Hemostasis is achieved by the physiological coagulation-inducing properties of the D-Stat. The D-Stat is biocompatible, non-pyrogenic, and intended to be left in situ.
Catalog Number
-
Brand Name
D-Stat® Flowable Hemostat
Version/Model Number
4000
Device Commercial Distribution Status
In Commercial Distribution
Commercial Distribution End Date
-
Issuing Agency
In HIBCC
MRI safety Status
Labeling does not contain MRI Safety Information
Device required to be labeled as containing natural rubber latex or dry natural rubber (21 CFR 801.437)
-
Device labeled as "Not made with natural rubber latex"
-
For Single-Use
Yes
Prescription Use (Rx)
Yes
Over the Counter (OTC)
-
Kit
-
Combination Product
Yes
Human Cell, Tissue or Cellular or Tissue-Based Product (HCT/P)
-
FDA Premarket Submission
-
Product Code
FRO
Product Code Name
Dressing, Wound, Drug
Public Device Record Key
a29d4773-e315-41a7-8436-1b903fb53977
Public Version Date
June 19, 2020
Public Version Number
3
DI Record Publish Date
September 19, 2014
Package DI Number
M20640001
Quantity per Package
5
Contains DI Package
M20640000
Package Discontinue Date
-
Package Status
In Commercial Distribution
Package Type
Box
Device Class | Device Class Description | No of Devices |
---|---|---|
1 | A medical device with low to moderate risk that requires general controls | 6 |
2 | A medical device with a moderate to high risk that requires special controls. | 238 |
U | Unclassified | 12 |