D-Stat® Flowable Hemostat - Each Vascular Solutions D-Stat® flowable hemostat - Vascular Solutions, Inc.

Duns Number:008999906

Device Description: Each Vascular Solutions D-Stat® flowable hemostat (D-Stat) includes the following componen Each Vascular Solutions D-Stat® flowable hemostat (D-Stat) includes the following components: Thrombin vial (5,000 units); Collagen (200mg), contained in 10ml syringe with attached mixing luer; Diluent vial (5ml); Mixing accessories (10ml syringe and needleless, non-coring vial access device); Applicator tips: (1) small bore tip, (1) 20-Gauge, 2.75" needle.The thrombin is a protein substance produced through a conversion reaction in which prothrombin of bovine origin is activated by tissue thromboplastin of bovine-origin in the presence of calcium chloride. It is supplied as a sterile powder that has been freeze-dried in the final container. Also contained in the thrombin vial are mannitol and sodium chloride. Mannitol is included to make the dried product friable and more readily soluble. The material contains no preservative and has been chromatographically purified. Thrombin requires no intermediate physiological agent for its reaction. It converts fibrinogen directly to fibrin.The collagen is a soft, white, pliable, absorbent hemostatic agent derived from purified bovine deep flexor tendon. It is prepared in a loose fibrous form. Collagen attracts platelets that adhere to the fibrils and undergo the release phenomenon to trigger aggregation of platelets into thrombi in the interstices of the fibrous mass. The collagen provides a three-dimensional matrix for additional strengthening of the clot. The effect on platelet adhesion and aggregation is not inhibited by heparin in vitro.The diluent is a sterile solution of calcium chloride and water, buffered with tromethamine (TRIS). Using the mixing accessories, both the thrombin and collagen are reconstituted with the diluent prior to use. The hemostat is delivered to the intended treatment site using the provided applicator tips. Hemostasis is achieved by the physiological coagulation-inducing properties of the D-Stat. The D-Stat is biocompatible, non-pyrogenic, and intended to be left in situ.

Want to know more about this Product? Request more information now!


More Product Details

Catalog Number

-

Brand Name

D-Stat® Flowable Hemostat

Version/Model Number

4000

Device Commercial Distribution Status

In Commercial Distribution

Commercial Distribution End Date

-

Issuing Agency

In HIBCC

Product Characteristics

MRI safety Status

Labeling does not contain MRI Safety Information

Device required to be labeled as containing natural rubber latex or dry natural rubber (21 CFR 801.437)

-

Device labeled as "Not made with natural rubber latex"

-

For Single-Use

Yes

Prescription Use (Rx)

Yes

Over the Counter (OTC)

-

Kit

-

Combination Product

Yes

Human Cell, Tissue or Cellular or Tissue-Based Product (HCT/P)

-

FDA Premarket Submission

-

Product Code Details

Product Code

FRO

Product Code Name

Dressing, Wound, Drug

Device Record Status

Public Device Record Key

a29d4773-e315-41a7-8436-1b903fb53977

Public Version Date

June 19, 2020

Public Version Number

3

DI Record Publish Date

September 19, 2014

Additional Identifiers

Package DI Number

M20640001

Quantity per Package

5

Contains DI Package

M20640000

Package Discontinue Date

-

Package Status

In Commercial Distribution

Package Type

Box

"VASCULAR SOLUTIONS, INC." Characteristics
Device Class Device Class Description No of Devices
1 A medical device with low to moderate risk that requires general controls 6
2 A medical device with a moderate to high risk that requires special controls. 238
U Unclassified 12