Other products from "HENRY SCHEIN, INC."
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 H65857007811 5700781 5700781 Metal Cutting Turbo Carbide FG 557 EJL BUR, DENTAL Henry Schein
2 H65857007801 5700780 5700780 Metal Cutting Turbo Carbide FG 2 EJL BUR, DENTAL Henry Schein
3 H65857007791 5700779 5700779 Carbide Bur HP 559 EJL BUR, DENTAL Henry Schein
4 H65857007781 5700778 5700778 Carbide Bur HP 701L EJL BUR, DENTAL Henry Schein
5 H65857007771 5700777 5700777 Carbide Bur HP 557 EJL BUR, DENTAL Henry Schein
6 H65857007761 5700776 5700776 Carbide Bur HP 700 EJL BUR, DENTAL Henry Schein
7 H65857007751 5700775 5700775 Carbide Bur HP 702L EJL BUR, DENTAL Henry Schein
8 H65857007741 5700774 5700774 Carbide Bur HP 1702 EJL BUR, DENTAL Henry Schein
9 H65857007731 5700773 5700773 Carbide Bur HP 1703L EJL BUR, DENTAL Henry Schein
10 H65857007721 5700772 5700772 Carbide Bur HP 560 EJL BUR, DENTAL Henry Schein
11 H65857007711 5700771 5700771 Carbide Bur HP 1703 EJL BUR, DENTAL Henry Schein
12 H65857007691 5700769 5700769 Carbide Bur FG 1556 EJL BUR, DENTAL Henry Schein
13 H65857007681 5700768 5700768 Carbide Bur FG 332L EJL BUR, DENTAL Henry Schein
14 00304040015575 1000573 1000573 Scissor Crown & Collar 4" Crvd EIR SCISSORS, COLLAR AND CROWN 1 Henry Schein
15 00304040015568 1000180 1000180 Scissor Crown & Collar 4" Strt EIR SCISSORS, COLLAR AND CROWN 1 Henry Schein
16 00304040015551 1000112 1000112 Scissor 276 Kelly Angled LRW SCISSORS, GENERAL, SURGICAL 1 Henry Schein
17 00304040015544 1003914 1003914 Retreat w/Epi MVL CORD, RETRACTION U Henry Schein
18 00304040015537 1000499 1000499 Retreat w/Epi MVL CORD, RETRACTION U Henry Schein
19 00304040015520 1003619 1003619 Retreat w/Epi MVL CORD, RETRACTION U Henry Schein
20 00304040015513 1002546 1002546 Retreat w/Aluminum Sulfate MVL CORD, RETRACTION U Henry Schein
21 00304040015506 1002020 1002020 Retreat w/Aluminum Sulfate MVL CORD, RETRACTION U Henry Schein
22 00304040015490 1008490 1008490 Retreat w/Aluminum Sulfate MVL CORD, RETRACTION U Henry Schein
23 00304040015476 5700135 5700135 Flowable Composite Compule C3 EBF MATERIAL, TOOTH SHADE, RESIN 2 Henry Schein
24 00304040015469 5700134 5700134 Flowable Composite Compule C1 EBF MATERIAL, TOOTH SHADE, RESIN 2 Henry Schein
25 00304040015452 5700133 5700133 Flowable Composite Compule B3 EBF MATERIAL, TOOTH SHADE, RESIN 2 Henry Schein
26 00304040015445 5700132 5700132 Flowable Composite Compule B1 EBF MATERIAL, TOOTH SHADE, RESIN 2 Henry Schein
27 00304040015414 5700129 5700129 Flowable Composite Compule A2 EBF MATERIAL, TOOTH SHADE, RESIN 2 Henry Schein
28 00304040015407 5700128 5700128 Flowable Composite Compule A1 EBF MATERIAL, TOOTH SHADE, RESIN 2 Henry Schein
29 00304040015391 5700127 5700127 Flowable Nanohybrid Composite Compule B1 EBF MATERIAL, TOOTH SHADE, RESIN 2 Henry Schein
30 00304040015384 5700126 5700126 Flowable Nanohybrid Composite Compule A3.5 EBF MATERIAL, TOOTH SHADE, RESIN 2 Henry Schein
31 00304040015377 5700125 5700125 Flowable Nanohybrid Composite Compule A3 EBF MATERIAL, TOOTH SHADE, RESIN 2 Henry Schein
32 00304040015360 5700124 5700124 Flowable Nanohybrid Composite Compule A2 EBF MATERIAL, TOOTH SHADE, RESIN 2 Henry Schein
33 00304040015353 5700123 5700123 Flowable Nanohybrid Composite Compule A1 EBF MATERIAL, TOOTH SHADE, RESIN 2 Henry Schein
34 00304040015346 9011426 9011426 Zirlux 16+ White 85x40x22 EIH POWDER, PORCELAIN 2 Henry Schein
35 00304040015339 9011254 9011254 Zirlux 16+ D4 85x40x22 EIH POWDER, PORCELAIN 2 Henry Schein
36 00304040015322 9011253 9011253 Zirlux 16+ D3 85x40x22 EIH POWDER, PORCELAIN 2 Henry Schein
37 00304040015315 9011252 9011252 Zirlux 16+ D2 85x40x22 EIH POWDER, PORCELAIN 2 Henry Schein
38 00304040015308 9011251 9011251 Zirlux 16+ C4 85x40x22 EIH POWDER, PORCELAIN 2 Henry Schein
39 00304040015292 9011250 9011250 Zirlux 16+ C3 85x40x22 EIH POWDER, PORCELAIN 2 Henry Schein
40 00304040015285 9011249 9011249 Zirlux 16+ C2 85x40x22 EIH POWDER, PORCELAIN 2 Henry Schein
41 00304040015278 9011248 9011248 Zirlux 16+ C1 85x40x22 EIH POWDER, PORCELAIN 2 Henry Schein
42 00304040015261 9011653 9011653 Zirlux 16+ 0M3 85x40x22 EIH POWDER, PORCELAIN 2 Henry Schein
43 00304040015254 9011652 9011652 Zirlux 16+ 0M2 85x40x22 EIH POWDER, PORCELAIN 2 Henry Schein
44 00304040015247 9011428 9011428 Zirlux 16+ 0M1 85x40x22 EIH POWDER, PORCELAIN 2 Henry Schein
45 00304040015230 9011247 9011247 Zirlux 16+ B4 85x40x22 EIH POWDER, PORCELAIN 2 Henry Schein
46 00304040015223 9011246 9011246 Zirlux 16+ B3 85x40x22 EIH POWDER, PORCELAIN 2 Henry Schein
47 00304040015216 9011245 9011245 Zirlux 16+ B2 85x40x22 EIH POWDER, PORCELAIN 2 Henry Schein
48 00304040015179 9011241 9011241 Zirlux 16+ A3 85x40x22 EIH POWDER, PORCELAIN 2 Henry Schein
49 00304040015162 9011240 9011240 Zirlux 16+ A2 85x40x22 EIH POWDER, PORCELAIN 2 Henry Schein
50 00304040015131 9011238 9011238 Zirlux 16+ D4 65x25x22 EIH POWDER, PORCELAIN 2 Henry Schein
Other products with the same Product Code "OEZ"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 00195451000416 12.0x30mm L6IVL120030 The IVL Catheter is a proprietary lithotripsy device delivered through the perip The IVL Catheter is a proprietary lithotripsy device delivered through the peripheral arterial system of the lower extremities to the site of an otherwise difficult to treat calcified stenosis. Energizing the lithotripsy device will generate pulsatile mechanical energy within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. The IVL Catheter is comprised of an integrated balloon with an array of lithotripsy emitters for the localized delivery of pulsatile mechanical energy. The system consists of an IVL Catheter, an IVL Connector Cable and an IVL Generator. The IVL Catheter is available in four (4) sizes: 8.0 x 30mm, 9.0 x 30mm, 10.0 x 30mm, and 12.0 x 30mm. The L6 Peripheral IVL Catheter is compatible with a 7 or 8F sheath and has a working length of 110cm.The Shockwave L6 Peripheral IVL Catheter shaft contains an inflation lumen, a guidewire lumen, and the lithotripsy emitters. The inflation lumen is used for inflation and deflation of the balloon with 50/50 saline/contrast medium. The guidewire lumen enables the use of a 0.018” guidewire to facilitate advancement of the catheter to and through the target stenosis. The system is designed as ‘Over-the-wire’ (OTW) with 110cm shaft working length, so an exchange length (300cm) guidewire is indicated. The emitters are positioned along the length of the balloon working length for delivery of pulsatile mechanical energy. The balloon is located near the distal tip of the catheter. Two radiopaque marker bands within the balloon denote the length of the balloon to aid in positioning of the balloon during treatment. The balloon is designed to provide an expandable segment of known length and diameter at a specific pressure. The proximal hub has three ports: one for inflation/deflation of the balloon, one for guidewire lumen, and one for connection to the IVL Connector Cable. Shockwave Medical L6 Intravascular Lithotripsy (IVL) Catheter SHOCKWAVE MEDICAL, INC.
2 00195451000409 10.0x30mm L6IVL100030 The IVL Catheter is a proprietary lithotripsy device delivered through the perip The IVL Catheter is a proprietary lithotripsy device delivered through the peripheral arterial system of the lower extremities to the site of an otherwise difficult to treat calcified stenosis. Energizing the lithotripsy device will generate pulsatile mechanical energy within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. The IVL Catheter is comprised of an integrated balloon with an array of lithotripsy emitters for the localized delivery of pulsatile mechanical energy. The system consists of an IVL Catheter, an IVL Connector Cable and an IVL Generator. The IVL Catheter is available in four (4) sizes: 8.0 x 30mm, 9.0 x 30mm, 10.0 x 30mm, and 12.0 x 30mm. The L6 Peripheral IVL Catheter is compatible with a 7 or 8F sheath and has a working length of 110cm.The Shockwave L6 Peripheral IVL Catheter shaft contains an inflation lumen, a guidewire lumen, and the lithotripsy emitters. The inflation lumen is used for inflation and deflation of the balloon with 50/50 saline/contrast medium. The guidewire lumen enables the use of a 0.018” guidewire to facilitate advancement of the catheter to and through the target stenosis. The system is designed as ‘Over-the-wire’ (OTW) with 110cm shaft working length, so an exchange length (300cm) guidewire is indicated. The emitters are positioned along the length of the balloon working length for delivery of pulsatile mechanical energy. The balloon is located near the distal tip of the catheter. Two radiopaque marker bands within the balloon denote the length of the balloon to aid in positioning of the balloon during treatment. The balloon is designed to provide an expandable segment of known length and diameter at a specific pressure. The proximal hub has three ports: one for inflation/deflation of the balloon, one for guidewire lumen, and one for connection to the IVL Connector Cable. Shockwave Medical L6 Intravascular Lithotripsy (IVL) Catheter SHOCKWAVE MEDICAL, INC.
3 00195451000393 9.0x30mm L6IVL090030 The IVL Catheter is a proprietary lithotripsy device delivered through the perip The IVL Catheter is a proprietary lithotripsy device delivered through the peripheral arterial system of the lower extremities to the site of an otherwise difficult to treat calcified stenosis. Energizing the lithotripsy device will generate pulsatile mechanical energy within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. The IVL Catheter is comprised of an integrated balloon with an array of lithotripsy emitters for the localized delivery of pulsatile mechanical energy. The system consists of an IVL Catheter, an IVL Connector Cable and an IVL Generator. The IVL Catheter is available in four (4) sizes: 8.0 x 30mm, 9.0 x 30mm, 10.0 x 30mm, and 12.0 x 30mm. The L6 Peripheral IVL Catheter is compatible with a 7 or 8F sheath and has a working length of 110cm.The Shockwave L6 Peripheral IVL Catheter shaft contains an inflation lumen, a guidewire lumen, and the lithotripsy emitters. The inflation lumen is used for inflation and deflation of the balloon with 50/50 saline/contrast medium. The guidewire lumen enables the use of a 0.018” guidewire to facilitate advancement of the catheter to and through the target stenosis. The system is designed as ‘Over-the-wire’ (OTW) with 110cm shaft working length, so an exchange length (300cm) guidewire is indicated. The emitters are positioned along the length of the balloon working length for delivery of pulsatile mechanical energy. The balloon is located near the distal tip of the catheter. Two radiopaque marker bands within the balloon denote the length of the balloon to aid in positioning of the balloon during treatment. The balloon is designed to provide an expandable segment of known length and diameter at a specific pressure. The proximal hub has three ports: one for inflation/deflation of the balloon, one for guidewire lumen, and one for connection to the IVL Connector Cable. Shockwave Medical L6 Intravascular Lithotripsy (IVL) Catheter SHOCKWAVE MEDICAL, INC.
4 00195451000386 8.0x30mm L6IVL080030 The IVL Catheter is a proprietary lithotripsy device delivered through the perip The IVL Catheter is a proprietary lithotripsy device delivered through the peripheral arterial system of the lower extremities to the site of an otherwise difficult to treat calcified stenosis. Energizing the lithotripsy device will generate pulsatile mechanical energy within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. The IVL Catheter is comprised of an integrated balloon with an array of lithotripsy emitters for the localized delivery of pulsatile mechanical energy. The system consists of an IVL Catheter, an IVL Connector Cable and an IVL Generator. The IVL Catheter is available in four (4) sizes: 8.0 x 30mm, 9.0 x 30mm, 10.0 x 30mm, and 12.0 x 30mm. The L6 Peripheral IVL Catheter is compatible with a 7 or 8F sheath and has a working length of 110cm.The Shockwave L6 Peripheral IVL Catheter shaft contains an inflation lumen, a guidewire lumen, and the lithotripsy emitters. The inflation lumen is used for inflation and deflation of the balloon with 50/50 saline/contrast medium. The guidewire lumen enables the use of a 0.018” guidewire to facilitate advancement of the catheter to and through the target stenosis. The system is designed as ‘Over-the-wire’ (OTW) with 110cm shaft working length, so an exchange length (300cm) guidewire is indicated. The emitters are positioned along the length of the balloon working length for delivery of pulsatile mechanical energy. The balloon is located near the distal tip of the catheter. Two radiopaque marker bands within the balloon denote the length of the balloon to aid in positioning of the balloon during treatment. The balloon is designed to provide an expandable segment of known length and diameter at a specific pressure. The proximal hub has three ports: one for inflation/deflation of the balloon, one for guidewire lumen, and one for connection to the IVL Connector Cable. Shockwave Medical L6 Intravascular Lithotripsy (IVL) Catheter SHOCKWAVE MEDICAL, INC.
5 00195451000348 4.0x40mm S4IVLK4040 The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array o The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The distal catheter and balloon are hydrophilic coated to increase lubricity. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave S4 SHOCKWAVE MEDICAL, INC.
6 00195451000331 3.5x40mm S4IVLK3540 The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array o The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The distal catheter and balloon are hydrophilic coated to increase lubricity. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave S4 SHOCKWAVE MEDICAL, INC.
7 00195451000324 3.0x40mm S4IVLK3040 The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array o The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The distal catheter and balloon are hydrophilic coated to increase lubricity. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave S4 SHOCKWAVE MEDICAL, INC.
8 00195451000317 2.5x40mm S4IVLK2540 The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array o The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The distal catheter and balloon are hydrophilic coated to increase lubricity. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave S4 SHOCKWAVE MEDICAL, INC.
9 00195451000287 8.0x60mm M5PIVL8060 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
10 00195451000270 7.0x60mm M5PIVL7060 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
11 00195451000263 6.5x60mm M5PIVL6560 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
12 00195451000256 6.0x60mm M5PIVL6060 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
13 00195451000249 5.5x60mm M5PIVL5560 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
14 00195451000232 5.0x60mm M5PIVL5060 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
15 00195451000225 4.5x60mm M5PIVL4560 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
16 00195451000218 4.0x60mm M5PIVL4060 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
17 00195451000201 3.5x60mm M5PIVL3560 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
18 00191072178947 LAPM00J PACEMAKER ACS AMERICAN CONTRACT SYSTEMS, INC.
19 00191072178787 BLPA73P PACEMAKER PACK ACS AMERICAN CONTRACT SYSTEMS, INC.
20 00191072178633 BLCV74L CV OR BASIN DRAPE PACK B ACS AMERICAN CONTRACT SYSTEMS, INC.
21 00191072178541 SAVT92F VEIN TRAY ACS AMERICAN CONTRACT SYSTEMS, INC.
22 00191072178510 SAPA90Z PACEMAKER ACS AMERICAN CONTRACT SYSTEMS, INC.
23 00191072178367 BLCV78M CV OR PACK A ACS AMERICAN CONTRACT SYSTEMS, INC.
24 00191072178251 FHPM10R PACEMAKER PACK ACS AMERICAN CONTRACT SYSTEMS, INC.
25 00191072178244 FHPE19J PERIPHERAL PACK ACS AMERICAN CONTRACT SYSTEMS, INC.
26 00191072178176 FHHR16V CUSTOM HEART PACK II ACS AMERICAN CONTRACT SYSTEMS, INC.
27 00191072178053 SACV80L OPEN HEART (SACV01/SACV02) ACS AMERICAN CONTRACT SYSTEMS, INC.
28 00191072178046 SACV02L HEART PART 2 ACS AMERICAN CONTRACT SYSTEMS, INC.
29 00191072178039 SACV01L HEART PART 1 ACS AMERICAN CONTRACT SYSTEMS, INC.
30 00191072178022 FHHP15Y CUSTOM HEART PACK I ACS AMERICAN CONTRACT SYSTEMS, INC.
31 00191072178015 BHVP49K VASCULAR ADD ON PACK ACS AMERICAN CONTRACT SYSTEMS, INC.
32 00191072177988 BHTY48P THORACOTOMY ACS AMERICAN CONTRACT SYSTEMS, INC.
33 00191072177896 BHPM65O PACEMAKER ACS AMERICAN CONTRACT SYSTEMS, INC.
34 00191072177872 BHOH95O OPEN HEART MAYFIELD B ACS AMERICAN CONTRACT SYSTEMS, INC.
35 00191072177865 BHOH94L OPEN HEART BACK TABLE A ACS AMERICAN CONTRACT SYSTEMS, INC.
36 00191072177414 CEVS11P VASCULAR PACK ACS AMERICAN CONTRACT SYSTEMS, INC.
37 00191072176196 FRVH22I VEIN HARVEST ACS AMERICAN CONTRACT SYSTEMS, INC.
38 00191072176189 FRVA25K VASCULAR PACK ACS AMERICAN CONTRACT SYSTEMS, INC.
39 00191072176097 FRCA60AF CABG PACK ACS AMERICAN CONTRACT SYSTEMS, INC.
40 00191072175892 RWAA01H ANEURYSM--LF ACS AMERICAN CONTRACT SYSTEMS, INC.
41 00191072175748 CXPA35R PACER ACS AMERICAN CONTRACT SYSTEMS, INC.
42 00191072175687 CXIM40F IMPLANT PACK ACS AMERICAN CONTRACT SYSTEMS, INC.
43 00191072175588 CXCV91Z CV THORACOTOMY ACS AMERICAN CONTRACT SYSTEMS, INC.
44 00191072175571 CXCV03AV OPEN HEART DRAPE I & II ACS AMERICAN CONTRACT SYSTEMS, INC.
45 00191072175564 CXCV02AT OPEN HEART PACK PART II ACS AMERICAN CONTRACT SYSTEMS, INC.
46 00191072175557 CXCV01AV OPEN HEART PACK PART I ACS AMERICAN CONTRACT SYSTEMS, INC.
47 00191072175465 FTVC35H VEIN CLOSURE ACS AMERICAN CONTRACT SYSTEMS, INC.
48 00191072175403 FTPM87J PACEMAKER PACK ACS AMERICAN CONTRACT SYSTEMS, INC.
49 00191072175069 SLPT76G PARACENTESIS THORACENTE ACS AMERICAN CONTRACT SYSTEMS, INC.
50 00191072174987 SLEP03H EP PACK ACS AMERICAN CONTRACT SYSTEMS, INC.