No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 EBCI80600 TD 1.x cortiQ PRO is a system that uses g.HIamp to map high-gamma broad band brain acti cortiQ PRO is a system that uses g.HIamp to map high-gamma broad band brain activity while running an experimental paradigm. The software helps to identify electrode positions coding differences in brain activity by means of experimental paradigm. cortiQ PRO performs the signal analysis in real-time and compares the high-gamma broad band activity during specific tasks. Then it performs a statistical analysis and visualizes electrodes coding the information that are statistically significant. It is abstracted from technical details of data acquisition, channel order and signal processing assuring robust and efficient measurements. OLU,GWL,OLT Normalizing Quantitative Electroencephalograph Software,Amplifier, Physiological Normalizing Quantitative Electroencephalograph Software,Amplifier, Physiological Signal,Non-Normalizing Quantitative Electroencephalograph Software 2 cortiQ PRO
2 EBCI11700 TD 1.x 1170 The g.Estim FES is a programmable constant-current stimulator that can deliver e The g.Estim FES is a programmable constant-current stimulator that can deliver electrical pulses with alternating polarities, lengths, amplitudes as well as trains of such pulses. The applied part is galvanic isolated. The stimulator is powered by a combination of USB bus-power and battery power. The host computer must use Microsoft Windows. The stimulator is controlled via a software API that uses a USB connection. A host application can be situated on top of the API and can control the stimulator. IPF,GZI Stimulator, Muscle, Powered,Stimulator, Neuromuscular, External Functional 2 g.Estim FES
3 EBCI7092US0 16-Channel Amplifier 7092US The g.HIamp is intended to be used for measuring, recording and analysing of ele The g.HIamp is intended to be used for measuring, recording and analysing of electrical activityof the brain and/or through the attachment of multiple electrodes at various locations to aid inmonitoring and diagnosis as routinely found in clinical settings for EEG. It captures the data,converts it into digital form and passes it on to a host computer running appropriate software. Thedevice can be used for adults, children, infants and animals. GWL Amplifier, Physiological Signal 2 g.HIamp
4 EBCI7091US0 32-Channel Amplifier 7091US The g.HIamp is intended to be used for measuring, recording and analysing of ele The g.HIamp is intended to be used for measuring, recording and analysing of electrical activityof the brain and/or through the attachment of multiple electrodes at various locations to aid inmonitoring and diagnosis as routinely found in clinical settings for EEG. It captures the data,converts it into digital form and passes it on to a host computer running appropriate software. Thedevice can be used for adults, children, infants and animals. GWL Amplifier, Physiological Signal 2 g.HIamp
5 EBCI70030 256-Channel Amplifier 7003 The g.HIamp is intended to be used for measuring, recording and analysing of ele The g.HIamp is intended to be used for measuring, recording and analysing of electrical activityof the brain and/or through the attachment of multiple electrodes at various locations to aid inmonitoring and diagnosis as routinely found in clinical settings for EEG. It captures the data,converts it into digital form and passes it on to a host computer running appropriate software. Thedevice can be used for adults, children, infants and animals. GWL Amplifier, Physiological Signal 2 g.HIamp
6 EBCI7002US0 144-Channel Amplifier 7002 The g.HIamp is intended to be used for measuring, recording and analysing of ele The g.HIamp is intended to be used for measuring, recording and analysing of electrical activityof the brain and/or through the attachment of multiple electrodes at various locations to aid inmonitoring and diagnosis as routinely found in clinical settings for EEG. It captures the data,converts it into digital form and passes it on to a host computer running appropriate software. Thedevice can be used for adults, children, infants and animals. GWL Amplifier, Physiological Signal 2 g.HIamp
7 EBCI70020 144-Channel Amplifier 7002 The g.HIamp is intended to be used for measuring, recording and analysing of ele The g.HIamp is intended to be used for measuring, recording and analysing of electrical activityof the brain and/or through the attachment of multiple electrodes at various locations to aid inmonitoring and diagnosis as routinely found in clinical settings for EEG. It captures the data,converts it into digital form and passes it on to a host computer running appropriate software. Thedevice can be used for adults, children, infants and animals. GWL Amplifier, Physiological Signal 2 g.HIamp
8 EBCI7001US0 80-Channel Amplifier 7001 The g.HIamp is intended to be used for measuring, recording and analysing of ele The g.HIamp is intended to be used for measuring, recording and analysing of electrical activityof the brain and/or through the attachment of multiple electrodes at various locations to aid inmonitoring and diagnosis as routinely found in clinical settings for EEG. It captures the data,converts it into digital form and passes it on to a host computer running appropriate software. Thedevice can be used for adults, children, infants and animals. GWL Amplifier, Physiological Signal 2 g.HIamp
9 EBCI70010 80-Channel Amplifier 7001 The g.HIamp is intended to be used for measuring, recording and analysing of ele The g.HIamp is intended to be used for measuring, recording and analysing of electrical activityof the brain and/or through the attachment of multiple electrodes at various locations to aid inmonitoring and diagnosis as routinely found in clinical settings for EEG. It captures the data,converts it into digital form and passes it on to a host computer running appropriate software. Thedevice can be used for adults, children, infants and animals. GWL Amplifier, Physiological Signal 2 g.HIamp
10 EBCI5720PRO0 8 FLEXIBLE channels 5720PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
11 EBCI5710PRO0 16 FLEXIBLE channels 5710PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
12 EBCI5700PRO0 32 FLEXIBLE channels 5700PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
13 EBCI5220PRO0 8-Channel Sahara 5220PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
14 EBCI5212PRO0 16-Channel-rX Sahara 5212PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
15 EBCI5211PRO0 16-Channel-mB Sahara 5211PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
16 EBCI5210PRO0 16-Channel Sahara 5210PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
17 EBCI5201PRO0 32-Channel-CSP Sahara 5201PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
18 EBCI5200PRO0 32-Channel Sahara 5200PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
19 EBCI5120PRO0 8-Channel 5120PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GWL,GXY Amplifier, Physiological Signal,Electrode, Cutaneous 2 g.Nautilus PRO
20 EBCI5112PRO0 16-Channel-rX 5112PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
21 EBCI5111PRO0 16-Channel-mB 5111PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
22 EBCI5110PRO0 16-Channel 5110PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
23 EBCI5101PRO0 32-Channel-CSP 5101PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
24 EBCI5100PRO0 32-Channel 5100PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
25 EBCI11500 1 1150 g.Estim PRO is a constant current, biphasic electrical stimulator intended for s g.Estim PRO is a constant current, biphasic electrical stimulator intended for stimulation of neural tissue. g.Estim PRO has an applied part of type BF with connectors for bipolar stimulation electrodes (anode and cathode). The device is controlled by a computer via USB connection. It also has digital outputs for synchronization with other devices. A hand-switch allows you to perform stimulation manually. Alternatively, a foot-switch can be used to explicitly enable/disable stimulation. GYC Electrode, Cortical 2 g.Estim PRO
26 EBCI0216US0 USB Biosignal Amplifier 0216US The g.USBamp is inteded to measuring, recording and analysis of electrical activ The g.USBamp is inteded to measuring, recording and analysis of electrical activity of the brain (EEG) and/or through the attachment of multiple electrodes at various locations to aid in monitoring and diagnosis as routinely found in clinical settings for the EEG. GWL Amplifier, Physiological Signal 2 g.USBamp
27 EBCI02160 USB Biosignal Amplifier 0216 The g.USBamp is inteded to measuring, recording and analysis of electrical activ The g.USBamp is inteded to measuring, recording and analysis of electrical activity of the brain (EEG) and/or through the attachment of multiple electrodes at various locations to aid in monitoring and diagnosis as routinely found in clinical settings for the EEG. GWL Amplifier, Physiological Signal 2 g.USBamp
Other products with the same Product Code "GWL"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 B195EE511 EE-511 physiological signal amplfier eego amplifier EEMAGINE MEDICAL IMAGING SOLUTIONS GMBH
2 B195EE430 EE-430 physiological signal amplfier eego amplifier EEMAGINE MEDICAL IMAGING SOLUTIONS GMBH
3 B195EE411 EE-411 physiological signal amplfier eego amplifier EEMAGINE MEDICAL IMAGING SOLUTIONS GMBH
4 B195EE224 EE-224 physiological signal amplfier eego amplifier EEMAGINE MEDICAL IMAGING SOLUTIONS GMBH
5 B195EE222 EE-222 physiological signal amplfier eego amplifier EEMAGINE MEDICAL IMAGING SOLUTIONS GMBH
6 B195EE221 EE-221 physiological signal amplfier eego amplifier EEMAGINE MEDICAL IMAGING SOLUTIONS GMBH
7 B195EE213 EE-213 physiological signal amplfier eego amplifier EEMAGINE MEDICAL IMAGING SOLUTIONS GMBH
8 B195EE212 EE-212 physiological signal amplfier eego amplifier EEMAGINE MEDICAL IMAGING SOLUTIONS GMBH
9 B195EE211 EE-211 physiological signal amplfier eego amplifier EEMAGINE MEDICAL IMAGING SOLUTIONS GMBH
10 10867718000299 ATLAS-HS-36-CHET-D18 31-0601-0082 The ATLAS-HS-36-CHET-D18 is a clinical headstage that allows two 18 contact DIXI The ATLAS-HS-36-CHET-D18 is a clinical headstage that allows two 18 contact DIXI electrode connectors to interface with the ATLAS Data Acquisition System. The ATLAS-HS-36-CHET-D18 uses electronic components to buffer single unit activity sensed by the electrodes and sends it to the ATLAS Data Acquisition System to be digitized. ATLAS-HS-36-CHET-D18 NEURALYNX, INC.
11 10850011306243 ATLAS MICROMED JB INTERFACE 31-0601-0088 The ATLAS MICROMED JB INTERFACE is a buffered interface between Micromed Jackbox The ATLAS MICROMED JB INTERFACE is a buffered interface between Micromed Jackbox and ATLAS. The ATLAS MICROMED JB INTERFACE uses electronic components to buffer single unit activity sensed by the electrodes and sends it to the ATLAS Data Acquisition System to be digitized. ATLAS MICROMED JB INTERFACE NEURALYNX, INC.
12 10850011306229 ATLAS-HS-36-CHET-IDC10 31-0601-0087 The ATLAS-HS-36-CHET-IDC10 is a clinical headstage that allows four X 3M 10 Pin The ATLAS-HS-36-CHET-IDC10 is a clinical headstage that allows four X 3M 10 Pin Receptacle Connector (e.g. 8510-4500PL) connectors to interface with the ATLAS Data Acquisition System. The ATLAS-HS-36-CHET-IDC10 uses electronic components to buffer single unit activity sensed by the electrodes and sends it to the ATLAS Data Acquisition System to be digitized. ATLAS-HS-36-CHET-IDC10 NEURALYNX, INC.
13 10850011306212 ATLAS-HS-36-CHET-A9 31-0601-0086 The ATLAS-HS-36-CHET-A9 is a clinical headstage that allows four X 9 contact Adt The ATLAS-HS-36-CHET-A9 is a clinical headstage that allows four X 9 contact Adtech electrode connectors to interface with the ATLAS Data Acquisition System. The ATLAS-HS-36-CHET-A9 uses electronic components to buffer single unit activity sensed by the electrodes and sends it to the ATLAS Data Acquisition System to be digitized. ATLAS-HS-36-CHET-A9 NEURALYNX, INC.
14 08719481170028 8 Physiologic data acquisition device TMSi TMSI
15 08719481170011 7 Porti TMSi TMSI
16 08437017440796 WF Enobio is a Wireless EEG, performs electroencephalographic measures with non-inv Enobio is a Wireless EEG, performs electroencephalographic measures with non-invasive technology.Enobio is a Wireless, battery-operated and portable electrophysiology sensor system for the recording of the electroencephalogram (EEG). It has been designated for use in a clinical environment or hospital. Enobio use must be controlled by specialized medical personnel able to guarantee the correct recording. ENOBIO NEUROELECTRICS BARCELONA SL
17 08056446900956 B8830073320 Patient-interface for EEG ambulatory recorder BE Micro PLUG-IN HEADBOX 19 CH MONO+2CH BIPOL EB NEURO SPA
18 08056446900949 B8830073310 Patient-interface for EEG ambulatory recorder BE Micro 21 CH MONO PLUG-IN HEADBOX EB NEURO SPA
19 08056446900376 B9700066010 EEG/EMG/EP Amplifier NeMus 2 EB NEURO SPA
20 08056446900369 B9800066010 EEG/EMG/EP Amplifier with accessories NeMus 2 EB NEURO SPA
21 08056446900154 B9100780100 Battery Charger for Battery Pack Battery Charger EB NEURO SPA
22 08056446900147 B9100820200 Battery Pack for EEG Amplifier BE PLUS LTM Battery Pack EB NEURO SPA
23 08056446900130 B9630082050 64 channels (193-256) patient-interface for EEG amplifier BE PLUS LTM PLUG-IN HEADBOX, 64CH (193-256) EB NEURO SPA
24 08056446900123 B9630082040 64 channels (129-192) patient-interface for EEG amplifier BE PLUS LTM PLUG-IN HEADBOX, 64CH (129-192) EB NEURO SPA
25 08056446900116 B9630082030 64 channels (65-128) patient-interface for EEG amplifier BE PLUS LTM PLUG-IN HEADBOX, 64CH (65-128) EB NEURO SPA
26 08056446900109 B9630082020 64 channels patient-interface for EEG amplifier BE PLUS LTM PLUG-IN HEADBOX, 64-CHANNELS EB NEURO SPA
27 08056446900093 B9630082010 32 channels patient-interface for EEG amplifier BE PLUS LTM PLUG-IN HEADBOX, 32-CHANNELS EB NEURO SPA
28 08056446900086 B9700082000 EEG Amplifier BE PLUS LTM EB NEURO SPA
29 08056446900079 B9800082000 EEG Amplifier with accessories BE PLUS LTM EB NEURO SPA
30 08056446900055 B9630073000 Patient-interface for EEG ambulatory recorder BE Micro Headbox EB NEURO SPA
31 08056446900048 B9630073300 Patient-interface for EEG ambulatory recorder BE Micro PLUG-IN HEADBOX EB NEURO SPA
32 08056446900024 B8830073000 USB interface for EEG ambulatory recorder BE Micro USB BRIDGE EB NEURO SPA
33 08056446900017 B9700073000 EEG Long Term-Abulatory Recorder BE Micro Recorder EB NEURO SPA
34 08056446900000 B9800073000 EEG Long Term-Abulatory System BE Micro EB NEURO SPA
35 05704736009546 9015A0012JP CLAVIS, DEVICE COMPLETE Alpine BioMed ALPINE BIOMED APS
36 05704736004091 8015A0012 CLAVIS, DEVICE COMPLETE Alpine BioMed ALPINE BIOMED APS
37 05704736002745 9015A0012 Clavis EMG/ Stim Device Alpine BioMed ALPINE BIOMED APS
38 05060275450783 Amp + BT + WI-FI Kit 2607 R-40 (24) LIFELINES LIMITED
39 05060275450776 Amp + WI-FI Kit 2606 R-40 (24) LIFELINES LIMITED
40 05060275450769 Amp + BT Kit 2605 R-40 (24) LIFELINES LIMITED
41 05060275450752 Amp Kit 2604 R-40 (24) LIFELINES LIMITED
42 05060275450745 Amp + BT + WI-FI 1414 R-40 (24) LIFELINES LIMITED
43 05060275450738 Amp + WI-FI 1413 R-40 (24) LIFELINES LIMITED
44 05060275450721 Amp + BT 1412 R-40 (24) LIFELINES LIMITED
45 05060275450714 Amp 1411 R-40 (24) LIFELINES LIMITED
46 05060275450653 T4A Kit 2800 Trackit T4A LIFELINES LIMITED
47 05060275450646 T4A 1600 Trackit T4A LIFELINES LIMITED
48 05060275450615 T4-32 + BT + WI-FI Kit Trackit T4 LIFELINES LIMITED
49 05060275450608 T4-32 + WI-FI Kit Trackit T4 LIFELINES LIMITED
50 05060275450592 T4-32 + BT Kit Trackit T4 LIFELINES LIMITED