Other products from "G.TEC MEDICAL ENGINEERING GMBH"
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 EBCI80600 TD 1.x cortiQ PRO is a system that uses g.HIamp to map high-gamma broad band brain acti cortiQ PRO is a system that uses g.HIamp to map high-gamma broad band brain activity while running an experimental paradigm. The software helps to identify electrode positions coding differences in brain activity by means of experimental paradigm. cortiQ PRO performs the signal analysis in real-time and compares the high-gamma broad band activity during specific tasks. Then it performs a statistical analysis and visualizes electrodes coding the information that are statistically significant. It is abstracted from technical details of data acquisition, channel order and signal processing assuring robust and efficient measurements. OLU,GWL,OLT Normalizing Quantitative Electroencephalograph Software,Amplifier, Physiological Normalizing Quantitative Electroencephalograph Software,Amplifier, Physiological Signal,Non-Normalizing Quantitative Electroencephalograph Software 2 cortiQ PRO
2 EBCI11700 TD 1.x 1170 The g.Estim FES is a programmable constant-current stimulator that can deliver e The g.Estim FES is a programmable constant-current stimulator that can deliver electrical pulses with alternating polarities, lengths, amplitudes as well as trains of such pulses. The applied part is galvanic isolated. The stimulator is powered by a combination of USB bus-power and battery power. The host computer must use Microsoft Windows. The stimulator is controlled via a software API that uses a USB connection. A host application can be situated on top of the API and can control the stimulator. IPF,GZI Stimulator, Muscle, Powered,Stimulator, Neuromuscular, External Functional 2 g.Estim FES
3 EBCI7092US0 16-Channel Amplifier 7092US The g.HIamp is intended to be used for measuring, recording and analysing of ele The g.HIamp is intended to be used for measuring, recording and analysing of electrical activityof the brain and/or through the attachment of multiple electrodes at various locations to aid inmonitoring and diagnosis as routinely found in clinical settings for EEG. It captures the data,converts it into digital form and passes it on to a host computer running appropriate software. Thedevice can be used for adults, children, infants and animals. GWL Amplifier, Physiological Signal 2 g.HIamp
4 EBCI7091US0 32-Channel Amplifier 7091US The g.HIamp is intended to be used for measuring, recording and analysing of ele The g.HIamp is intended to be used for measuring, recording and analysing of electrical activityof the brain and/or through the attachment of multiple electrodes at various locations to aid inmonitoring and diagnosis as routinely found in clinical settings for EEG. It captures the data,converts it into digital form and passes it on to a host computer running appropriate software. Thedevice can be used for adults, children, infants and animals. GWL Amplifier, Physiological Signal 2 g.HIamp
5 EBCI7003US0 256-Channel Amplifier 7003 The g.HIamp is intended to be used for measuring, recording and analysing of ele The g.HIamp is intended to be used for measuring, recording and analysing of electrical activityof the brain and/or through the attachment of multiple electrodes at various locations to aid inmonitoring and diagnosis as routinely found in clinical settings for EEG. It captures the data,converts it into digital form and passes it on to a host computer running appropriate software. Thedevice can be used for adults, children, infants and animals. GWL Amplifier, Physiological Signal 2 g.HIamp
6 EBCI70030 256-Channel Amplifier 7003 The g.HIamp is intended to be used for measuring, recording and analysing of ele The g.HIamp is intended to be used for measuring, recording and analysing of electrical activityof the brain and/or through the attachment of multiple electrodes at various locations to aid inmonitoring and diagnosis as routinely found in clinical settings for EEG. It captures the data,converts it into digital form and passes it on to a host computer running appropriate software. Thedevice can be used for adults, children, infants and animals. GWL Amplifier, Physiological Signal 2 g.HIamp
7 EBCI7002US0 144-Channel Amplifier 7002 The g.HIamp is intended to be used for measuring, recording and analysing of ele The g.HIamp is intended to be used for measuring, recording and analysing of electrical activityof the brain and/or through the attachment of multiple electrodes at various locations to aid inmonitoring and diagnosis as routinely found in clinical settings for EEG. It captures the data,converts it into digital form and passes it on to a host computer running appropriate software. Thedevice can be used for adults, children, infants and animals. GWL Amplifier, Physiological Signal 2 g.HIamp
8 EBCI70020 144-Channel Amplifier 7002 The g.HIamp is intended to be used for measuring, recording and analysing of ele The g.HIamp is intended to be used for measuring, recording and analysing of electrical activityof the brain and/or through the attachment of multiple electrodes at various locations to aid inmonitoring and diagnosis as routinely found in clinical settings for EEG. It captures the data,converts it into digital form and passes it on to a host computer running appropriate software. Thedevice can be used for adults, children, infants and animals. GWL Amplifier, Physiological Signal 2 g.HIamp
9 EBCI7001US0 80-Channel Amplifier 7001 The g.HIamp is intended to be used for measuring, recording and analysing of ele The g.HIamp is intended to be used for measuring, recording and analysing of electrical activityof the brain and/or through the attachment of multiple electrodes at various locations to aid inmonitoring and diagnosis as routinely found in clinical settings for EEG. It captures the data,converts it into digital form and passes it on to a host computer running appropriate software. Thedevice can be used for adults, children, infants and animals. GWL Amplifier, Physiological Signal 2 g.HIamp
10 EBCI70010 80-Channel Amplifier 7001 The g.HIamp is intended to be used for measuring, recording and analysing of ele The g.HIamp is intended to be used for measuring, recording and analysing of electrical activityof the brain and/or through the attachment of multiple electrodes at various locations to aid inmonitoring and diagnosis as routinely found in clinical settings for EEG. It captures the data,converts it into digital form and passes it on to a host computer running appropriate software. Thedevice can be used for adults, children, infants and animals. GWL Amplifier, Physiological Signal 2 g.HIamp
11 EBCI5720PRO0 8 FLEXIBLE channels 5720PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
12 EBCI5710PRO0 16 FLEXIBLE channels 5710PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
13 EBCI5700PRO0 32 FLEXIBLE channels 5700PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
14 EBCI5220PRO0 8-Channel Sahara 5220PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
15 EBCI5212PRO0 16-Channel-rX Sahara 5212PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
16 EBCI5210PRO0 16-Channel Sahara 5210PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
17 EBCI5201PRO0 32-Channel-CSP Sahara 5201PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
18 EBCI5200PRO0 32-Channel Sahara 5200PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
19 EBCI5120PRO0 8-Channel 5120PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GWL,GXY Amplifier, Physiological Signal,Electrode, Cutaneous 2 g.Nautilus PRO
20 EBCI5112PRO0 16-Channel-rX 5112PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
21 EBCI5111PRO0 16-Channel-mB 5111PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
22 EBCI5110PRO0 16-Channel 5110PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
23 EBCI5101PRO0 32-Channel-CSP 5101PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
24 EBCI5100PRO0 32-Channel 5100PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
25 EBCI11500 1 1150 g.Estim PRO is a constant current, biphasic electrical stimulator intended for s g.Estim PRO is a constant current, biphasic electrical stimulator intended for stimulation of neural tissue. g.Estim PRO has an applied part of type BF with connectors for bipolar stimulation electrodes (anode and cathode). The device is controlled by a computer via USB connection. It also has digital outputs for synchronization with other devices. A hand-switch allows you to perform stimulation manually. Alternatively, a foot-switch can be used to explicitly enable/disable stimulation. GYC Electrode, Cortical 2 g.Estim PRO
26 EBCI0216US0 USB Biosignal Amplifier 0216US The g.USBamp is inteded to measuring, recording and analysis of electrical activ The g.USBamp is inteded to measuring, recording and analysis of electrical activity of the brain (EEG) and/or through the attachment of multiple electrodes at various locations to aid in monitoring and diagnosis as routinely found in clinical settings for the EEG. GWL Amplifier, Physiological Signal 2 g.USBamp
27 EBCI02160 USB Biosignal Amplifier 0216 The g.USBamp is inteded to measuring, recording and analysis of electrical activ The g.USBamp is inteded to measuring, recording and analysis of electrical activity of the brain (EEG) and/or through the attachment of multiple electrodes at various locations to aid in monitoring and diagnosis as routinely found in clinical settings for the EEG. GWL Amplifier, Physiological Signal 2 g.USBamp
Other products with the same Product Codes "GXY, GWL"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 00682891210678 21067 Electrodes 2"x3.5" (4pcs.) Zewa ZEWA, INC.
2 00682891210647 21064 Mini Go Replacement Electrodes Zewa ZEWA, INC.
3 00682891210593 21059 Electrodes Deluxe 3.5"x5" (4pcs.) Zewa ZEWA, INC.
4 00682891210579 21057 Electrodes Belt (4pcs.) Zewa ZEWA, INC.
5 00682891210555 21055 Electrodes Deluxe 2"x2" (4pcs.) Zewa ZEWA, INC.
6 00682891210517 21051 Electrodes 2"x2" (8pcs.) Zewa ZEWA, INC.
7 00682891210500 21050 Electrodes Deluxe 2"x2" (8pcs.) Zewa ZEWA, INC.
8 00682891210494 21049 Electrodes Deluxe 2"x2" (4pcs.) Zewa ZEWA, INC.
9 00682891210487 21048 Electrodes 2"x2" (4pcs.) Zewa ZEWA, INC.
10 00677346310867 CB900S 2" x 3.5" Butterfly w/Snap Freedom Stim PEPIN MANUFACTURING, INC.
11 00677346310850 500 2" x 3.5" Butterfly w/ Snap Regentex PEPIN MANUFACTURING, INC.
12 00677346310843 WTEK Multi-Kit Tricot Advantrode PEPIN MANUFACTURING, INC.
13 00677346310836 WTPK Multi-Kit Tricot Advantrode PEPIN MANUFACTURING, INC.
14 00677346310829 rX-WWS125o 1.5" x 2.5" (4cm x 6.5cm) Oval White Spunlace Advantrode PEPIN MANUFACTURING, INC.
15 00677346310812 20-0570 1.875" Rd Conductive Fabric AdvanTrode PEPIN MANUFACTURING, INC.
16 00677346310805 T-TF900S 2" x 3.5" Butterfly w/ Snap Freedom Stim PEPIN MANUFACTURING, INC.
17 00677346310799 K-TF900S 2" x 3.5" Butterfly w/ Snap Freedom Stim PEPIN MANUFACTURING, INC.
18 00677346310782 WFP900S 2"x 3.5" Pediatric Butterfly w/ Snap Freedom Stim PEPIN MANUFACTURING, INC.
19 00677346310775 TF900L 2" x 3.5" Butterfly w/ Lead Freedom Stim PEPIN MANUFACTURING, INC.
20 00677346310768 TF900S 2"x 3.5" Butterfly w/ Snap Freedom Stim PEPIN MANUFACTURING, INC.
21 00677346310751 NC89800-P 2" x 3.5" Pediatric Butterfly w/ Snap Freedom Stim PEPIN MANUFACTURING, INC.
22 00677346310744 NC89800 2" x 3.5" Butterfly w/ snap Freedom Stim PEPIN MANUFACTURING, INC.
23 00677346310737 800FLY-PIN Butterfly w/ Lead Connector AdvanTrode PEPIN MANUFACTURING, INC.
24 00677346310720 1000LC 1" Rd w/ lead connector AdvanTrode PEPIN MANUFACTURING, INC.
25 00677346310713 800LC .8" Rd. w/ Lead Connector AdvanTrode PEPIN MANUFACTURING, INC.
26 00677346310706 800-FLY-SNAP Butterfly w/ Mini-Snap Connector AdvanTrode PEPIN MANUFACTURING, INC.
27 00677346310690 1000MSC 1" Round w/ Mini-Snap Connector AdvanTrode PEPIN MANUFACTURING, INC.
28 00677346310683 800MSC .8" Round w/ Mini-Snap Connector AdvanTrode PEPIN MANUFACTURING, INC.
29 00677346310676 BLST185 1.875" x 5" (4.8cm x 12.7cm) Square AdvanTrode PEPIN MANUFACTURING, INC.
30 00677346310669 BLST18 1.875" x 1.875" (4.8cm x4.8cm) Square AdvanTrode PEPIN MANUFACTURING, INC.
31 00677346310652 SSB22 2" x 2" (5cm x 5cm) Square AdvanTrode PEPIN MANUFACTURING, INC.
32 00677346310638 PT24 2" x 4" (5cm x 10cm) Rectangle AdvanTrode PEPIN MANUFACTURING, INC.
33 00677346310621 PT22 2" x 2" (5cm x 5cm) Square AdvanTrode PEPIN MANUFACTURING, INC.
34 00677346310614 PC13NG 1.75" x 3.75" (4.5cm x 9.5cm) Rectangle - No Gel AdvanTrode PEPIN MANUFACTURING, INC.
35 00677346310607 PC13 1.75" x 3.75" (4.5cm x 9.5cm) Rectangle AdvanTrode PEPIN MANUFACTURING, INC.
36 00677346310591 PC11NG 1.75" x 1.75" (4.5cm x 4.5cm) Square - No Gel AdvanTrode PEPIN MANUFACTURING, INC.
37 00677346310584 PC11 1.75" x 1.75" (4.5cm x 4.5cm) Square AdvanTrode PEPIN MANUFACTURING, INC.
38 00677346310577 WWS3ET 3" (7.5cm) Round AdvanTrode PEPIN MANUFACTURING, INC.
39 00677346310560 WWS24oET 2" x 4" (5cm x 10cm) Oval AdvanTrode PEPIN MANUFACTURING, INC.
40 00677346310553 WWS13ET 1.75" x 3.75" (4.5cm x 9.5cm) Rectangle AdvanTrode PEPIN MANUFACTURING, INC.
41 00677346310546 WWS22ET 2" x 2" (5cm x 5cm) Square AdvanTrode PEPIN MANUFACTURING, INC.
42 00677346310539 WWS2ET 2" (5cm) Round AdvanTrode PEPIN MANUFACTURING, INC.
43 00677346310522 BWT35 3" x 5" (7.5cm x 13cm) Rectangle AdvanTrode PEPIN MANUFACTURING, INC.
44 00677346310515 BST13 1.75" x 3.75" (4.5cm x 9.5cm) Rectangle with Snap AdvanTrode PEPIN MANUFACTURING, INC.
45 00677346310508 BWT13 1.75" x 3.75" (4.5cm x 9.5cm) Rectangle AdvanTrode PEPIN MANUFACTURING, INC.
46 00677346310492 BST11 1.75" x 1.75" (4.5cm x 4.5cm) Square with Snap AdvanTrode PEPIN MANUFACTURING, INC.
47 00677346310485 BWT11 1.75" x 1.75" (4.5cm x 4.5cm) Square AdvanTrode PEPIN MANUFACTURING, INC.
48 00677346310461 WF1315 13" x 1.5" (33cm x 4cm) Backlasp AdvanTrode PEPIN MANUFACTURING, INC.
49 00677346310454 WF58 5" x 8" (13cm x 20cm) Rectangle AdvanTrode PEPIN MANUFACTURING, INC.