No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 EBCI80600 TD 1.x cortiQ PRO is a system that uses g.HIamp to map high-gamma broad band brain acti cortiQ PRO is a system that uses g.HIamp to map high-gamma broad band brain activity while running an experimental paradigm. The software helps to identify electrode positions coding differences in brain activity by means of experimental paradigm. cortiQ PRO performs the signal analysis in real-time and compares the high-gamma broad band activity during specific tasks. Then it performs a statistical analysis and visualizes electrodes coding the information that are statistically significant. It is abstracted from technical details of data acquisition, channel order and signal processing assuring robust and efficient measurements. OLU,GWL,OLT Normalizing Quantitative Electroencephalograph Software,Amplifier, Physiological Normalizing Quantitative Electroencephalograph Software,Amplifier, Physiological Signal,Non-Normalizing Quantitative Electroencephalograph Software 2 cortiQ PRO
2 EBCI11700 TD 1.x 1170 The g.Estim FES is a programmable constant-current stimulator that can deliver e The g.Estim FES is a programmable constant-current stimulator that can deliver electrical pulses with alternating polarities, lengths, amplitudes as well as trains of such pulses. The applied part is galvanic isolated. The stimulator is powered by a combination of USB bus-power and battery power. The host computer must use Microsoft Windows. The stimulator is controlled via a software API that uses a USB connection. A host application can be situated on top of the API and can control the stimulator. IPF,GZI Stimulator, Muscle, Powered,Stimulator, Neuromuscular, External Functional 2 g.Estim FES
3 EBCI7092US0 16-Channel Amplifier 7092US The g.HIamp is intended to be used for measuring, recording and analysing of ele The g.HIamp is intended to be used for measuring, recording and analysing of electrical activityof the brain and/or through the attachment of multiple electrodes at various locations to aid inmonitoring and diagnosis as routinely found in clinical settings for EEG. It captures the data,converts it into digital form and passes it on to a host computer running appropriate software. Thedevice can be used for adults, children, infants and animals. GWL Amplifier, Physiological Signal 2 g.HIamp
4 EBCI7091US0 32-Channel Amplifier 7091US The g.HIamp is intended to be used for measuring, recording and analysing of ele The g.HIamp is intended to be used for measuring, recording and analysing of electrical activityof the brain and/or through the attachment of multiple electrodes at various locations to aid inmonitoring and diagnosis as routinely found in clinical settings for EEG. It captures the data,converts it into digital form and passes it on to a host computer running appropriate software. Thedevice can be used for adults, children, infants and animals. GWL Amplifier, Physiological Signal 2 g.HIamp
5 EBCI7003US0 256-Channel Amplifier 7003 The g.HIamp is intended to be used for measuring, recording and analysing of ele The g.HIamp is intended to be used for measuring, recording and analysing of electrical activityof the brain and/or through the attachment of multiple electrodes at various locations to aid inmonitoring and diagnosis as routinely found in clinical settings for EEG. It captures the data,converts it into digital form and passes it on to a host computer running appropriate software. Thedevice can be used for adults, children, infants and animals. GWL Amplifier, Physiological Signal 2 g.HIamp
6 EBCI70030 256-Channel Amplifier 7003 The g.HIamp is intended to be used for measuring, recording and analysing of ele The g.HIamp is intended to be used for measuring, recording and analysing of electrical activityof the brain and/or through the attachment of multiple electrodes at various locations to aid inmonitoring and diagnosis as routinely found in clinical settings for EEG. It captures the data,converts it into digital form and passes it on to a host computer running appropriate software. Thedevice can be used for adults, children, infants and animals. GWL Amplifier, Physiological Signal 2 g.HIamp
7 EBCI7002US0 144-Channel Amplifier 7002 The g.HIamp is intended to be used for measuring, recording and analysing of ele The g.HIamp is intended to be used for measuring, recording and analysing of electrical activityof the brain and/or through the attachment of multiple electrodes at various locations to aid inmonitoring and diagnosis as routinely found in clinical settings for EEG. It captures the data,converts it into digital form and passes it on to a host computer running appropriate software. Thedevice can be used for adults, children, infants and animals. GWL Amplifier, Physiological Signal 2 g.HIamp
8 EBCI70020 144-Channel Amplifier 7002 The g.HIamp is intended to be used for measuring, recording and analysing of ele The g.HIamp is intended to be used for measuring, recording and analysing of electrical activityof the brain and/or through the attachment of multiple electrodes at various locations to aid inmonitoring and diagnosis as routinely found in clinical settings for EEG. It captures the data,converts it into digital form and passes it on to a host computer running appropriate software. Thedevice can be used for adults, children, infants and animals. GWL Amplifier, Physiological Signal 2 g.HIamp
9 EBCI7001US0 80-Channel Amplifier 7001 The g.HIamp is intended to be used for measuring, recording and analysing of ele The g.HIamp is intended to be used for measuring, recording and analysing of electrical activityof the brain and/or through the attachment of multiple electrodes at various locations to aid inmonitoring and diagnosis as routinely found in clinical settings for EEG. It captures the data,converts it into digital form and passes it on to a host computer running appropriate software. Thedevice can be used for adults, children, infants and animals. GWL Amplifier, Physiological Signal 2 g.HIamp
10 EBCI70010 80-Channel Amplifier 7001 The g.HIamp is intended to be used for measuring, recording and analysing of ele The g.HIamp is intended to be used for measuring, recording and analysing of electrical activityof the brain and/or through the attachment of multiple electrodes at various locations to aid inmonitoring and diagnosis as routinely found in clinical settings for EEG. It captures the data,converts it into digital form and passes it on to a host computer running appropriate software. Thedevice can be used for adults, children, infants and animals. GWL Amplifier, Physiological Signal 2 g.HIamp
11 EBCI5720PRO0 8 FLEXIBLE channels 5720PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
12 EBCI5710PRO0 16 FLEXIBLE channels 5710PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
13 EBCI5700PRO0 32 FLEXIBLE channels 5700PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
14 EBCI5220PRO0 8-Channel Sahara 5220PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
15 EBCI5212PRO0 16-Channel-rX Sahara 5212PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
16 EBCI5210PRO0 16-Channel Sahara 5210PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
17 EBCI5201PRO0 32-Channel-CSP Sahara 5201PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
18 EBCI5200PRO0 32-Channel Sahara 5200PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
19 EBCI5120PRO0 8-Channel 5120PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GWL,GXY Amplifier, Physiological Signal,Electrode, Cutaneous 2 g.Nautilus PRO
20 EBCI5112PRO0 16-Channel-rX 5112PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
21 EBCI5111PRO0 16-Channel-mB 5111PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
22 EBCI5110PRO0 16-Channel 5110PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
23 EBCI5101PRO0 32-Channel-CSP 5101PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
24 EBCI5100PRO0 32-Channel 5100PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
25 EBCI11500 1 1150 g.Estim PRO is a constant current, biphasic electrical stimulator intended for s g.Estim PRO is a constant current, biphasic electrical stimulator intended for stimulation of neural tissue. g.Estim PRO has an applied part of type BF with connectors for bipolar stimulation electrodes (anode and cathode). The device is controlled by a computer via USB connection. It also has digital outputs for synchronization with other devices. A hand-switch allows you to perform stimulation manually. Alternatively, a foot-switch can be used to explicitly enable/disable stimulation. GYC Electrode, Cortical 2 g.Estim PRO
26 EBCI0216US0 USB Biosignal Amplifier 0216US The g.USBamp is inteded to measuring, recording and analysis of electrical activ The g.USBamp is inteded to measuring, recording and analysis of electrical activity of the brain (EEG) and/or through the attachment of multiple electrodes at various locations to aid in monitoring and diagnosis as routinely found in clinical settings for the EEG. GWL Amplifier, Physiological Signal 2 g.USBamp
27 EBCI02160 USB Biosignal Amplifier 0216 The g.USBamp is inteded to measuring, recording and analysis of electrical activ The g.USBamp is inteded to measuring, recording and analysis of electrical activity of the brain (EEG) and/or through the attachment of multiple electrodes at various locations to aid in monitoring and diagnosis as routinely found in clinical settings for the EEG. GWL Amplifier, Physiological Signal 2 g.USBamp
Other products with the same Product Codes "GXY, GWL"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 00816625020190 TENS Lead-Lok Butterfly 200-11 BIO MEDICAL INNOVATIONS
2 00816625020183 TENS 2.0" X 4.0" Oval electrode patch in pouch of 4 each electrodes. TPWT4-8 BIO MEDICAL INNOVATIONS
3 00816625020176 TENS 2.5" Oval electrode patch in pouch of 4 each electrodes. TPWT4-7 BIO MEDICAL INNOVATIONS
4 00816625020169 TENS 3.0" Round electrode patch in pouch of 4 each electrodes. TPWT4-6 BIO MEDICAL INNOVATIONS
5 00816625020152 TENS 2.0" Round electrode patch in pouch of 4 each electrodes. TPWT4-5 BIO MEDICAL INNOVATIONS
6 00816625020145 TENS 1.25" Round electrode patch in pouch of 4 each electrodes. TPWT4-4 BIO MEDICAL INNOVATIONS
7 00816625020138 TENS 2.0" X 2.0" Square electrode patch in pouch of 4 each electrodes. TPWT4-3 BIO MEDICAL INNOVATIONS
8 00816625020121 TENS 2.0" X 2.0" Square electrode patch in pouch of 4 each electrodes. TPWT4-2 BIO MEDICAL INNOVATIONS
9 00816625020114 TENS 3.0" Round electrode patch in pouch of 4 each electrodes SS-6 BIO MEDICAL INNOVATIONS
10 00816625020107 TENS 2.0" Round electrode patch in pouch of 4 each electrodes SS-5 BIO MEDICAL INNOVATIONS
11 00816625020091 TENS 1.75" X 3.75" Rectangular electrode patch in pouch of 4 each electrodes SS-3 BIO MEDICAL INNOVATIONS
12 00816625020084 TENS 2.0" X 2.0" Square electrode patch in pouch of 4 each electrodes SS-2 BIO MEDICAL INNOVATIONS
13 00816625020077 TENS 2.0" X4.0" Oval electrode patch in pouch of 4 each electrodes. BF-8 BIO MEDICAL INNOVATIONS
14 00816625020060 TENS 1.25" X 2.25" Oval electrode patch in pouch of 4 each electrodes. BF-7 BIO MEDICAL INNOVATIONS
15 00816625020053 TENS 3.0" Round electrode patch in pouch of 4 each electrodes. BF-6 BIO MEDICAL INNOVATIONS
16 00816625020046 TENS 2.0" Round electrode patch in pouch of 4 each electrodes. BF-5 BIO MEDICAL INNOVATIONS
17 00816625020039 TENS 1.25" Round electrode patch in pouch of 4 each electrodes. BF-4 BIO MEDICAL INNOVATIONS
18 00816625020022 TENS 1.875" X 3.75" Rectangular electrode patch in pouch of 4 each electrodes. BF-3 BIO MEDICAL INNOVATIONS
19 00816625020015 TENS 2" X 2" Square electrode patch in pouch of 4 each electrodes. BF-2 BIO MEDICAL INNOVATIONS
20 00816312026443 MRQS232415 3 electrode arrays, MR Disposable Quick Connect Slim Cup with 2 MR Conditional R 3 electrode arrays, MR Disposable Quick Connect Slim Cup with 2 MR Conditional Recording Surface Electrodes Rhythmlink® RHYTHMLINK INTERNATIONAL, LLC
21 00816312026191 MRQS33215 3 electrode arrays, 10mm Disposable Quick Connect Slim Cup Electrode Array with 3 electrode arrays, 10mm Disposable Quick Connect Slim Cup Electrode Array with extension cable [28 pack] plus 4 MR Sticky Pads Rhythmlink® RHYTHMLINK INTERNATIONAL, LLC
22 00816312026160 MRQD310100315 3 electrode arrays, 10mm Disposable Quick Connect Deep Cup Electrode Array with 3 electrode arrays, 10mm Disposable Quick Connect Deep Cup Electrode Array with extension cable [23 Pack] Rhythmlink® RHYTHMLINK INTERNATIONAL, LLC
23 00816312026153 MRQD33020 Kit of 3 Electrode Arrays, 10mm Disposable Quick Connect Deep Up Electrod Array Kit of 3 Electrode Arrays, 10mm Disposable Quick Connect Deep Up Electrod Array with extension cable [28 Pack] Plus 2 MR Recording Sticky Pads Rhythmlink® RHYTHMLINK INTERNATIONAL, LLC
24 00816312026122 RLITCTGNL1.0 Kit of 21 1.0m Guardian Needle Electrodes and 1 Standard Template (Large) Rhythmlink® RHYTHMLINK INTERNATIONAL, LLC
25 00816312026115 RLITCTGNM1.0 Kit of 21 1.0m Guardian Needle Electrodes and 1 Standard Template (Medium) Rhythmlink® RHYTHMLINK INTERNATIONAL, LLC
26 00816312026085 RLSPGSP120 40x50mm Ground Sticky Pads Electrodes Rhythmlink® RHYTHMLINK INTERNATIONAL, LLC
27 00816312025996 MRQS308080815 3 electrode arrays, MR Disposable Quick Connect Slim Cup Electrode Array [24 pack] Rhythmlink® RHYTHMLINK INTERNATIONAL, LLC
28 00816312025958 MRQW309090615 3 electrode arrays, Disposable Quick Connect Webb Electrode Array [24 pack] Rhythmlink® RHYTHMLINK INTERNATIONAL, LLC
29 00816312025941 MRQS2070715 2 electrode arrays, Disposable Quick Connect Slim Cups with extension cable [14 pack] Rhythmlink® RHYTHMLINK INTERNATIONAL, LLC
30 00816312025934 MRQS310100315 3 electrode arrays, Disposable Quick Connect Slim Cups with extension cable [23 pack] Rhythmlink® RHYTHMLINK INTERNATIONAL, LLC
31 00816312025897 STMRECG261525 Kit of Ground, Recording, and Stimulating Sticky Pad Electrodes Rhythmlink® RHYTHMLINK INTERNATIONAL, LLC
32 00816312025880 RLITD2910 Kit of 25 Deep Cup Electrodes and 4 Recording Sticky Pad Electrodes Rhythmlink® RHYTHMLINK INTERNATIONAL, LLC
33 00816312025859 MRQD309070915 3 electrode arrays, 10mm Disposable Quick Connect Deep Cup Electrode Array with 3 electrode arrays, 10mm Disposable Quick Connect Deep Cup Electrode Array with extension cable [25 Pack] Rhythmlink® RHYTHMLINK INTERNATIONAL, LLC
34 00816312025835 445-10G-120PTP Reusable Disc Electrodes, EEG, Gold Plated Discs, 120 inch Twisted Leadwire Rhythmlink® RHYTHMLINK INTERNATIONAL, LLC
35 00816312025828 445-10G-96PTP Reusable Disc Electrodes, EEG, Gold Plated Discs, 96 inch Twisted Leadwire Rhythmlink® RHYTHMLINK INTERNATIONAL, LLC
36 00816312025811 445-10G-72PTP Reusable Disc Electrodes, EEG, Gold Plated Discs, 72 inch Twisted Leadwire Rhythmlink® RHYTHMLINK INTERNATIONAL, LLC
37 00816312025804 445-10G-60PTP Reusable Disc Electrodes, EEG, Gold Plated Discs, 60 inch Twisted Leadwire Rhythmlink® RHYTHMLINK INTERNATIONAL, LLC
38 00816312025798 445-10G-48PTP Reusable Disc Electrodes, EEG, Gold Plated Discs, 48 inch Twisted Leadwire Rhythmlink® RHYTHMLINK INTERNATIONAL, LLC
39 00816312025606 295-2-36STP Reusable Finger Clip Electrode, EMG, 36 inch Shielded Leadwire Rhythmlink® RHYTHMLINK INTERNATIONAL, LLC
40 00816312025590 295-2-48TP Reusable Finger Clip Electrode, EMG, 48 inch Leadwire Rhythmlink® RHYTHMLINK INTERNATIONAL, LLC
41 00816312025583 295-2-24TP Reusable Finger Clip Electrode, EMG, 24 inch Leadwire Rhythmlink® RHYTHMLINK INTERNATIONAL, LLC
42 00816312025576 293-2SL-48TP Reusable Ring Electrode w/Slide Lock, EMG, 48 inch Leadwire Rhythmlink® RHYTHMLINK INTERNATIONAL, LLC
43 00816312025569 293-2SL-24TP Reusable Ring Electrode w/Slide Lock, EMG, 24 inch Leadwire Rhythmlink® RHYTHMLINK INTERNATIONAL, LLC
44 00816312025552 293-2-36STP Reusable Ring Electrode, EMG, 36 inch Shielded Leadwire Rhythmlink® RHYTHMLINK INTERNATIONAL, LLC
45 00816312025545 293-2-48TP Reusable Ring Electrode, EMG, 48 inch Leadwire Rhythmlink® RHYTHMLINK INTERNATIONAL, LLC
46 00816312025538 293-2-24TP Reusable Ring Electrode, EMG, 24 inch Leadwire Rhythmlink® RHYTHMLINK INTERNATIONAL, LLC
47 00816312025521 285-32-48TP Reusable Ground Electrode, EMG, 32 mm Nickel Plated Disc Rhythmlink® RHYTHMLINK INTERNATIONAL, LLC
48 00816312025514 285-32-24TP Reusable Ground Electrode, EMG, 32 mm Nickel Plated Disc Rhythmlink® RHYTHMLINK INTERNATIONAL, LLC
49 00816312025460 266-9S-36STP Reusable Paired Disc Electrode, EMG, 9 mm Silver Discs, Shielded Leadwire Rhythmlink® RHYTHMLINK INTERNATIONAL, LLC