Other products from "G.TEC MEDICAL ENGINEERING GMBH"
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 EBCI80600 TD 1.x cortiQ PRO is a system that uses g.HIamp to map high-gamma broad band brain acti cortiQ PRO is a system that uses g.HIamp to map high-gamma broad band brain activity while running an experimental paradigm. The software helps to identify electrode positions coding differences in brain activity by means of experimental paradigm. cortiQ PRO performs the signal analysis in real-time and compares the high-gamma broad band activity during specific tasks. Then it performs a statistical analysis and visualizes electrodes coding the information that are statistically significant. It is abstracted from technical details of data acquisition, channel order and signal processing assuring robust and efficient measurements. OLU,GWL,OLT Normalizing Quantitative Electroencephalograph Software,Amplifier, Physiological Normalizing Quantitative Electroencephalograph Software,Amplifier, Physiological Signal,Non-Normalizing Quantitative Electroencephalograph Software 2 cortiQ PRO
2 EBCI11700 TD 1.x 1170 The g.Estim FES is a programmable constant-current stimulator that can deliver e The g.Estim FES is a programmable constant-current stimulator that can deliver electrical pulses with alternating polarities, lengths, amplitudes as well as trains of such pulses. The applied part is galvanic isolated. The stimulator is powered by a combination of USB bus-power and battery power. The host computer must use Microsoft Windows. The stimulator is controlled via a software API that uses a USB connection. A host application can be situated on top of the API and can control the stimulator. IPF,GZI Stimulator, Muscle, Powered,Stimulator, Neuromuscular, External Functional 2 g.Estim FES
3 EBCI7092US0 16-Channel Amplifier 7092US The g.HIamp is intended to be used for measuring, recording and analysing of ele The g.HIamp is intended to be used for measuring, recording and analysing of electrical activityof the brain and/or through the attachment of multiple electrodes at various locations to aid inmonitoring and diagnosis as routinely found in clinical settings for EEG. It captures the data,converts it into digital form and passes it on to a host computer running appropriate software. Thedevice can be used for adults, children, infants and animals. GWL Amplifier, Physiological Signal 2 g.HIamp
4 EBCI7091US0 32-Channel Amplifier 7091US The g.HIamp is intended to be used for measuring, recording and analysing of ele The g.HIamp is intended to be used for measuring, recording and analysing of electrical activityof the brain and/or through the attachment of multiple electrodes at various locations to aid inmonitoring and diagnosis as routinely found in clinical settings for EEG. It captures the data,converts it into digital form and passes it on to a host computer running appropriate software. Thedevice can be used for adults, children, infants and animals. GWL Amplifier, Physiological Signal 2 g.HIamp
5 EBCI7003US0 256-Channel Amplifier 7003 The g.HIamp is intended to be used for measuring, recording and analysing of ele The g.HIamp is intended to be used for measuring, recording and analysing of electrical activityof the brain and/or through the attachment of multiple electrodes at various locations to aid inmonitoring and diagnosis as routinely found in clinical settings for EEG. It captures the data,converts it into digital form and passes it on to a host computer running appropriate software. Thedevice can be used for adults, children, infants and animals. GWL Amplifier, Physiological Signal 2 g.HIamp
6 EBCI70030 256-Channel Amplifier 7003 The g.HIamp is intended to be used for measuring, recording and analysing of ele The g.HIamp is intended to be used for measuring, recording and analysing of electrical activityof the brain and/or through the attachment of multiple electrodes at various locations to aid inmonitoring and diagnosis as routinely found in clinical settings for EEG. It captures the data,converts it into digital form and passes it on to a host computer running appropriate software. Thedevice can be used for adults, children, infants and animals. GWL Amplifier, Physiological Signal 2 g.HIamp
7 EBCI7002US0 144-Channel Amplifier 7002 The g.HIamp is intended to be used for measuring, recording and analysing of ele The g.HIamp is intended to be used for measuring, recording and analysing of electrical activityof the brain and/or through the attachment of multiple electrodes at various locations to aid inmonitoring and diagnosis as routinely found in clinical settings for EEG. It captures the data,converts it into digital form and passes it on to a host computer running appropriate software. Thedevice can be used for adults, children, infants and animals. GWL Amplifier, Physiological Signal 2 g.HIamp
8 EBCI70020 144-Channel Amplifier 7002 The g.HIamp is intended to be used for measuring, recording and analysing of ele The g.HIamp is intended to be used for measuring, recording and analysing of electrical activityof the brain and/or through the attachment of multiple electrodes at various locations to aid inmonitoring and diagnosis as routinely found in clinical settings for EEG. It captures the data,converts it into digital form and passes it on to a host computer running appropriate software. Thedevice can be used for adults, children, infants and animals. GWL Amplifier, Physiological Signal 2 g.HIamp
9 EBCI7001US0 80-Channel Amplifier 7001 The g.HIamp is intended to be used for measuring, recording and analysing of ele The g.HIamp is intended to be used for measuring, recording and analysing of electrical activityof the brain and/or through the attachment of multiple electrodes at various locations to aid inmonitoring and diagnosis as routinely found in clinical settings for EEG. It captures the data,converts it into digital form and passes it on to a host computer running appropriate software. Thedevice can be used for adults, children, infants and animals. GWL Amplifier, Physiological Signal 2 g.HIamp
10 EBCI70010 80-Channel Amplifier 7001 The g.HIamp is intended to be used for measuring, recording and analysing of ele The g.HIamp is intended to be used for measuring, recording and analysing of electrical activityof the brain and/or through the attachment of multiple electrodes at various locations to aid inmonitoring and diagnosis as routinely found in clinical settings for EEG. It captures the data,converts it into digital form and passes it on to a host computer running appropriate software. Thedevice can be used for adults, children, infants and animals. GWL Amplifier, Physiological Signal 2 g.HIamp
11 EBCI5720PRO0 8 FLEXIBLE channels 5720PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
12 EBCI5710PRO0 16 FLEXIBLE channels 5710PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
13 EBCI5700PRO0 32 FLEXIBLE channels 5700PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
14 EBCI5220PRO0 8-Channel Sahara 5220PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
15 EBCI5212PRO0 16-Channel-rX Sahara 5212PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
16 EBCI5211PRO0 16-Channel-mB Sahara 5211PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
17 EBCI5210PRO0 16-Channel Sahara 5210PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
18 EBCI5201PRO0 32-Channel-CSP Sahara 5201PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
19 EBCI5200PRO0 32-Channel Sahara 5200PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
20 EBCI5120PRO0 8-Channel 5120PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GWL,GXY Amplifier, Physiological Signal,Electrode, Cutaneous 2 g.Nautilus PRO
21 EBCI5112PRO0 16-Channel-rX 5112PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
22 EBCI5110PRO0 16-Channel 5110PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
23 EBCI5101PRO0 32-Channel-CSP 5101PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
24 EBCI5100PRO0 32-Channel 5100PRO The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (E The g.Nautilus PRO is intended to be used to acquire the electroencephalogram (EEG) and transmit it wirelessly to a computer. GXY,GWL Electrode, Cutaneous,Amplifier, Physiological Signal 2 g.Nautilus PRO
25 EBCI11500 1 1150 g.Estim PRO is a constant current, biphasic electrical stimulator intended for s g.Estim PRO is a constant current, biphasic electrical stimulator intended for stimulation of neural tissue. g.Estim PRO has an applied part of type BF with connectors for bipolar stimulation electrodes (anode and cathode). The device is controlled by a computer via USB connection. It also has digital outputs for synchronization with other devices. A hand-switch allows you to perform stimulation manually. Alternatively, a foot-switch can be used to explicitly enable/disable stimulation. GYC Electrode, Cortical 2 g.Estim PRO
26 EBCI0216US0 USB Biosignal Amplifier 0216US The g.USBamp is inteded to measuring, recording and analysis of electrical activ The g.USBamp is inteded to measuring, recording and analysis of electrical activity of the brain (EEG) and/or through the attachment of multiple electrodes at various locations to aid in monitoring and diagnosis as routinely found in clinical settings for the EEG. GWL Amplifier, Physiological Signal 2 g.USBamp
27 EBCI02160 USB Biosignal Amplifier 0216 The g.USBamp is inteded to measuring, recording and analysis of electrical activ The g.USBamp is inteded to measuring, recording and analysis of electrical activity of the brain (EEG) and/or through the attachment of multiple electrodes at various locations to aid in monitoring and diagnosis as routinely found in clinical settings for the EEG. GWL Amplifier, Physiological Signal 2 g.USBamp
Other products with the same Product Codes "GXY, GWL"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 00840067103906 302295-000-032 Ring Electrode with 32in lead attached length Cadwell CADWELL INDUSTRIES, INC.
2 00840067103081 302295-000-020 Ring Electrode with 20in lead attached length Cadwell CADWELL INDUSTRIES, INC.
3 00840067102824 199283-000-025 ESSENTIA REMOTE INPUT CABLE, 25FT Arc Essentia CADWELL INDUSTRIES, INC.
4 00840067102817 199283-000-010 ESSENTIA REMOTE INPUT CABLE, 10FT Arc Essentia CADWELL INDUSTRIES, INC.
5 00840067102770 302767-200 Cadwell EEG Gold Cup Electrode CADWELL INDUSTRIES, INC.
6 00840067102725 203104-200 ELECTRODE, EXG GOLD CUP, 6 LEAD/36 IN Cadwell Gold Cup Electrode CADWELL INDUSTRIES, INC.
7 00840067102268 190301-200 Apollo 32 Channel Amplifier Apollo CADWELL INDUSTRIES, INC.
8 00840067102251 190302-200 Apollo 64 Channel Amplifier Apollo CADWELL INDUSTRIES, INC.
9 00840067102237 190304-200 Apollo Recorder Apollo CADWELL INDUSTRIES, INC.
10 00840067102015 302736-200 Cadwell EEG Gold Cup Electrode Pak CADWELL INDUSTRIES, INC.
11 00840067101681 302703-200 Cadwell Feld Pads CADWELL INDUSTRIES, INC.
12 00840067101674 302768-200 Cadwell EEG Gold Cup Electrode CADWELL INDUSTRIES, INC.
13 00840067101667 302695-200 Cadwell EEG Gold Cup Electrode CADWELL INDUSTRIES, INC.
14 00840067101650 302691-200 Cadwell EEG Gold Cup Electrode Pak CADWELL INDUSTRIES, INC.
15 00840067101643 302694-200 Cadwell Paired Disc Electrode CADWELL INDUSTRIES, INC.
16 00840067101636 302647-200 Cadwell EEG Gold Cup Electrode CADWELL INDUSTRIES, INC.
17 00840067101629 302644-200 Cadwell EEG Gold Cup Electrode CADWELL INDUSTRIES, INC.
18 00840067101612 302641-200 Cadwell EEG Gold Cup Electrode CADWELL INDUSTRIES, INC.
19 00840067101599 302087-200 Cadwell Single Disc Electrode CADWELL INDUSTRIES, INC.
20 00840067101582 302085-200 Cadwell Bar Electrode CADWELL INDUSTRIES, INC.
21 00840067101575 302786-200 Cadwell Bar Electrode CADWELL INDUSTRIES, INC.
22 00840067101568 302787-200 Cadwell Single Disc Electrode CADWELL INDUSTRIES, INC.
23 00840067101551 302788-200 Cadwell Ring Electrode CADWELL INDUSTRIES, INC.
24 00840067101414 302291-000 Cadwell Disposable Disc Electrodes CADWELL INDUSTRIES, INC.
25 00840067101407 302290-000 Cadwell Disposable Disc Electrodes CADWELL INDUSTRIES, INC.
26 00840067101391 302288-000 Cadwell Disposable Ground Electrodes CADWELL INDUSTRIES, INC.
27 00840067101384 302287-000 Cadwell Bar Electrodes CADWELL INDUSTRIES, INC.
28 00840067101377 302286-000 Cadwell Disposable Ring Electrodes CADWELL INDUSTRIES, INC.
29 00840067101360 302221-200 Cadwell Disposable Patient Starter Kit CADWELL INDUSTRIES, INC.
30 00840067101346 302120-000 Cadwell Disposable Patient Pak Refill CADWELL INDUSTRIES, INC.
31 00840067101247 302217-000 Cadwell Disposable Tab Electrodes CADWELL INDUSTRIES, INC.
32 00840067101162 302285-000 Cadwell Disposable Tab Electrodes CADWELL INDUSTRIES, INC.
33 00840067101155 302247-200 Cadwell Bar Electrode CADWELL INDUSTRIES, INC.
34 00840067101148 302197-200 Cadwell Single Disc Electrode CADWELL INDUSTRIES, INC.
35 00840067101131 302196-200 Cadwell Single Disc Electrode CADWELL INDUSTRIES, INC.
36 00840067101124 302189-200 Cadwell Ground Plate Electrode CADWELL INDUSTRIES, INC.
37 00840067101117 302172-200 Cadwell Ring Electrode CADWELL INDUSTRIES, INC.
38 00840067101100 302058-200 Cadwell EEG Gold Cup Electrode CADWELL INDUSTRIES, INC.
39 00840067101087 302155-200 Cadwell EEG Gold Cup Electrode CADWELL INDUSTRIES, INC.
40 00840067101070 302150-200 Cadwell Ground Plate Electrode CADWELL INDUSTRIES, INC.
41 00840067101063 302147-200 Cadwell Bar Electrode CADWELL INDUSTRIES, INC.
42 00840067101049 302136-200 Cadwell Single Disc Electrode CADWELL INDUSTRIES, INC.
43 00840067101032 302135-200 Cadwell Single Disc Electrode CADWELL INDUSTRIES, INC.
44 00840067101025 302132-200 Cadwell EEG Gold Cup Electrode CADWELL INDUSTRIES, INC.
45 00840067100929 302294-000-120 Cadwell Disposable Disc Electrode CADWELL INDUSTRIES, INC.
46 00840067100912 302294-000-080 Cadwell Disposable Disc Electrode CADWELL INDUSTRIES, INC.
47 00840067100905 302294-000-040 Cadwell Disposable Disc Electrode CADWELL INDUSTRIES, INC.
48 00840067100899 302294-000-020 Cadwell Disposable Disc Electrode CADWELL INDUSTRIES, INC.
49 00840067100882 302854-000-100 Cadwell Disposable Surface Electrode CADWELL INDUSTRIES, INC.
50 00840067100875 302854-000-060 Cadwell Disposable Surface Electrode CADWELL INDUSTRIES, INC.