More-Cell-System is intended for use as a tissue containment system during minim
More-Cell-System is intended for use as a tissue containment system during minimally invasive gynecologic laparoscopic surgeryto enable the isolation and containment of tissue considered benign, resected during multi-site laparoscopic surgery for powermorcellation and removal.
PMU
Containment System, Laparoscopic Power Morcellation, With Instrument Port
More-Cell Bag is intended for use as a tissue containment system during minimall
More-Cell Bag is intended for use as a tissue containment system during minimally invasive gynecologic laparoscopic surgery to enable the isolation and containment of tissue considered benign, resected during multi-site laparoscopic surgery for power morcellation and removal.
PMU
Containment System, Laparoscopic Power Morcellation, With Instrument Port
More-Cell-System is intended for use as a tissue containment system during minim
More-Cell-System is intended for use as a tissue containment system during minimally invasive gynecologic laparoscopic surgery to enable the isolation and containment of tissue considered benign, resected during multi-site laparoscopic surgery for power morcellation and removal.
PMU
Containment System, Laparoscopic Power Morcellation, With Instrument Port
FiXcision is an EO‐sterilized, single use, multi‐part, manual cutting instrument
FiXcision is an EO‐sterilized, single use, multi‐part, manual cutting instrument for use during anal fistula surgery in coloproctology. FiXcision enables circumferential tissue removal for the treatment of simple anal fistulae.
Loading unit for blunt dissection for A.M.I.-dock Applicator 10mm.The Bluntdisse
Loading unit for blunt dissection for A.M.I.-dock Applicator 10mm.The Bluntdissect DLU`s are part of the A.M.I.-dock System which is a set of instruments intended for using during laparoscopic surgical procedures.The system consists of:- various A.M.I.-dock Applicators, delivered non sterile,- various A.M.I.-dock DLU’s (Disposable Loading Units), sterile packed, for different applications in the OR.
Handle and instrument for A.M.I. loading units for A.M.I.-dock Applicator 5mm.Th
Handle and instrument for A.M.I. loading units for A.M.I.-dock Applicator 5mm.The A.M.I.-dock Applicator serves as endoscopic multiple use applicator for the A.M.I.-dock Disposable Loading Units (DLU).
Mag for retrieving speciment for 10 mm trocars.The various types of retrieval ba
Mag for retrieving speciment for 10 mm trocars.The various types of retrieval bags belonging to the A.M.I. TissueBag System are intended for safe removal of specimen (appendix, gallbladder, ovaries, fibroid tumours and other tissues, and calculi …) during laparoscopic surgery.fsing.
The Comfort Drain is a flexible, silicone, elastic drain with knotless closure t
The Comfort Drain is a flexible, silicone, elastic drain with knotless closure that facilitates drainage of perianal fistulas.
Handle and instrument for A.M.I. loading units for A.M.I.-dock Applicator 10mm.T
Handle and instrument for A.M.I. loading units for A.M.I.-dock Applicator 10mm.The A.M.I.-dock Applicator serves as endoscopic multiple use carrier to operate the A.M.I.-dock Disposable Loading Units (DLU).
Handle and instrument for A.M.I. loading units for A.M.I.-dock Applicator 5mm.Th
Handle and instrument for A.M.I. loading units for A.M.I.-dock Applicator 5mm.The A.M.I.-dock Applicator serves as endoscopic carrier for the A.M.I.-dock Disposable Loading Units (DLU).
Electronic unit for identifying the localised haemorrhoidal arteries by means of
Electronic unit for identifying the localised haemorrhoidal arteries by means of acoustic signals. Part of the Wi-3 HAL-RAR System.The Wi-3 HAL-RAR System (HAL - Hemorrhoidal Artery Ligation, RAR - Recto Anal Repair) is a Bluetooth-enabled, pulsed Doppler, ultrasound system intended to be used for detecting hemorrhoidal arteries, to manually ligate these arteries (HAL), and subsequently carry out a mucopexy of hemorrhoidal tissue prolapse (RAR) if necessary.
Knot pusher for placing knots for laparoscopic surgery.The various Knotpushers a
Knot pusher for placing knots for laparoscopic surgery.The various Knotpushers are intended for ligature passing and knot tying.
The A.M.I. FasciaCutter Disposable Instrument is a sterile, disposable scalpel t
The A.M.I. FasciaCutter Disposable Instrument is a sterile, disposable scalpel that is used to for enlargement of trocar incisions. The instrument is used in conjunction withan A.M.I. TissueBag for retrieval of specimen bags. The A.M.I. Fascia Cutter Disposable Instrument allows for easy removal of specimens in order to avoid risk of damaging the specimen bag while enlarging the trocar incision.
Loading unit for retrieving specimen for A.M.I.-dock Applicator 10mm.The various
Loading unit for retrieving specimen for A.M.I.-dock Applicator 10mm.The various types of retrieval bags belonging to the A.M.I. TissueBag System are intended for safe removal of specimen (appendix, gallbladder, ovaries, fibroid tumours and other tissues, and calculi) during laparoscopic surgery.
The Wi-3 Arm is used to fix the outer (white) HAL-RAR sleeve in place to enhance
The Wi-3 Arm is used to fix the outer (white) HAL-RAR sleeve in place to enhance gradual opening of the RAR window when mucopexy is performed, allowing the surgeon, the nurse or any assistant to comfortably hold the system in position.The Wi-3 HAL-RAR System (HAL - Hemorrhoidal Artery Ligation, RAR - Recto Anal Repair) is a Bluetooth-enabled, pulsed Doppler, ultrasound system intended to be used for detecting hemorrhoidal arteries, to manually ligate these arteries (HAL), and subsequently carry out a mucopexy of hemorrhoidal tissue prolapse (RAR) if necessary.
Bag for retrieving specimen. The various types of retrieval bags belonging to th
Bag for retrieving specimen. The various types of retrieval bags belonging to the A.M.I. TissueBag System are intended for safe removal of specimen (appendix, gallbladder, ovaries, fibroid tumours and other tissues, and calculi) during laparoscopic surgery.
For easy closure the Comfort Drain Grasper can be used as a helpful instrument t
For easy closure the Comfort Drain Grasper can be used as a helpful instrument to connect the couplingpiece with the cut / trimmed drain during the implantation of a Comfort Drain.
The monopolar hook are reusable (40 uses) endoscopic instrument. It is connected
The monopolar hook are reusable (40 uses) endoscopic instrument. It is connected to the control handle and is used with the single-use Monopolar Protection sleeve (ref. M-1304). Each Arm is composed of an insulated shaft, a connection cover and an articulated instrument that provides distal mobility1. Tilting the tip with respect to the axis of the shaft2. Rotation of the tip around its own axis3. Opening-closing the tip/needle holder
The monopolar maryland are reusable (40 uses) endoscopic instrument. It is conne
The monopolar maryland are reusable (40 uses) endoscopic instrument. It is connected to the control handle and is used with the single-use Monopolar Protection sleeve (ref. M-1304). Each Arm is composed of an insulated shaft, a connection cover and an articulated instrument that provides distal mobility1. Tilting the tip with respect to the axis of the shaft2. Rotation of the tip around its own axis3. Opening-closing the tip/needle holder
The monopolar scissors are reusable (20 uses) endoscopic instrument. It is conne
The monopolar scissors are reusable (20 uses) endoscopic instrument. It is connected to the control handle and is used with the single-use Monopolar Protection sleeve (ref. M-1304). Each Arm is composed of an insulated shaft, a connection cover and an articulated instrument that provides distal mobility1. Tilting the tip with respect to the axis of the shaft2. Rotation of the tip around its own axis3. Opening-closing the tip/needle holder
The arm needle holder is a reusable (40 uses) endoscopic instrument. It is conne
The arm needle holder is a reusable (40 uses) endoscopic instrument. It is connected to the control handle and is used with the single-use Protection sleeve (ref. 2090-MDS). Each Arm is composed of a shaft, a connection cover and an articulated instrument followed by the needle holder tip that provides distal mobility.1. Tilting the tip with respect to the axis of the shaft2. Rotation of the tip around its own axis3. Opening-closing the tip/needle holder
The Sleeve applicator tool purpose is to help the installation of Protection sle
The Sleeve applicator tool purpose is to help the installation of Protection sleeve 2090-MDS onto the tip of Arm Needle holder B-1301
Monopolar protection sleeve is designed to be installed onto Monopolar Arms B-13
Monopolar protection sleeve is designed to be installed onto Monopolar Arms B-1304, B-1505 and B-1506 and to remain there for the duration of the surgical procedure. It is provided non-sterile and is single use; it must be sterilize before the use. Its purpose is to protect the gear mechanism from its environment and guarantee the electrical insulation. It prevents the distal part of the arms (except for the tip) from coming into contact with the patient's tissues, thereby preventing the risk of lesions and burning subsequent to such contact.
Protection sleeve 2090-MDS is designed to be placed on the Needle holder arm and
Protection sleeve 2090-MDS is designed to be placed on the Needle holder arm and to remain there for the duration of the surgical procedure. Its purpose is to protect the gear mechanism from its environment. It also helps prevent the gears from coming into contact with the patient's tissues, thereby preventing the risk of lesion formation subsequent to such mechanical contact. It is provided non-sterile and is single use; it must be sterilize before the use.
The DEX Device control handle for left handed is comprised of an ergonomic hand
The DEX Device control handle for left handed is comprised of an ergonomic hand piece that can turn on its own axis thanks to the comfort joint. This axis can also allow the user to perform a complete manual prono-supination movement without moving his shoulder.The control handle has command buttons that activate the different degrees of freedom or the Arm. The three axes are motorized: Open/Close, Tilt (Left/Right), Rotation+/Rotation-.
The DEX Device control handle is comprised of an ergonomic hand piece that can t
The DEX Device control handle is comprised of an ergonomic hand piece that can turn on its own axis thanks to the comfort joint. This axis can also allow the user to perform a complete manual prono-supination movement without moving his shoulder.The control handle has command buttons that activate the different degrees of freedom or the Arm. The three axes are motorized: Open/Close, Tilt (Left/Right), Rotation+/Rotation-.