Other products from "MYOTRONICS NOROMED, INC"
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 D79244500 J5 4450 The J5 Myomonitor TENS unit is a muscle stimulator used to create a physiologica The J5 Myomonitor TENS unit is a muscle stimulator used to create a physiologically relaxed state of the muscles of mastication. NUW Stimulator, Muscle, Powered, Dental J5 Myo-Monitor
2 D79209940 K7/CMS Multiple sensors in an extremely light weight (four ounce) spectacle-like array, Multiple sensors in an extremely light weight (four ounce) spectacle-like array, track the motion of a tiny magnet attached to the lower incisal gingiva with adhesive material. The configuration is totally non-invasive and, unlike clutches, does not interfere with patient function. The opposing sensors are wide apart permitting unobstructed access to the oral cavity for taking bite registrations and other clinical procedures, and the system is virtually immune from effects of slight head motion or nearby metallic or electronic interference. A patient education mode is included to simplify patient understanding and staff training. NFS,IKN,KZM Device, Jaw Tracking, For Monitoring Jaw Positions,Electromyograph, Diagnostic,D Device, Jaw Tracking, For Monitoring Jaw Positions,Electromyograph, Diagnostic,Device, Muscle Monitoring K7 Evaluation System-CMS
3 D79209930 K7/EMG Utilizing high quality bipolar surface electrodes, surface EMG data can be taken Utilizing high quality bipolar surface electrodes, surface EMG data can be taken from up to eight muscle sites simultaneously and in real time. The program permits taking electromyography data either at rest or in function. All eight channels may be displayed simultaneously, for a period of 15 seconds (one visual screen width). The K7/EMG signal processing circuitry provides unsurpassed protection against system noise or motion artifact. The patient education mode permits quick and easy patient education as to status of masticatory muscles. KZM,NFS,IKN Device, Muscle Monitoring,Device, Jaw Tracking, For Monitoring Jaw Positions,Ele Device, Muscle Monitoring,Device, Jaw Tracking, For Monitoring Jaw Positions,Electromyograph, Diagnostic 1 K7 Evaluation System-EMG
4 D79209750 K7/ESG TMJ Vibration (Sound) Evaluation System. A lightweight headset holds highly sens TMJ Vibration (Sound) Evaluation System. A lightweight headset holds highly sensitive vibration transducers over each TM joint, enabling simultaneous, bilateral capture of tissue vibrations emanating from joint sounds. Vibration (sound) data is correlated to vertical dimension of opening and closing, providing clinicians with valuable information to aid in assessing the status of articular disk and joint function. KZM,IKN,NFS,NFQ Device, Muscle Monitoring,Electromyograph, Diagnostic,Device, Jaw Tracking, For Device, Muscle Monitoring,Electromyograph, Diagnostic,Device, Jaw Tracking, For Monitoring Jaw Positions,Device, Dental Sonography, For Monitoring Jaw Sounds 1 K7 Evaluation System-ESG
5 D7921013 101 High quality disposable (single use) electrodes for surface electromyography (EMG). KZM,NUW Device, Muscle Monitoring,Stimulator, Muscle, Powered, Dental 2 Monotrode 101
6 D79240702 4070 Non-jelled TENS Electrodes for use with Myomonitor.Designed for patients with s Non-jelled TENS Electrodes for use with Myomonitor.Designed for patients with sideburns or a beard. NUW Stimulator, Muscle, Powered, Dental 2 Myotrode One without Gel
7 D792N150MES0 Static EMG Scanner Noromed SEMG, with broader operating ranges, greater sensitivity, and unsurpasse Noromed SEMG, with broader operating ranges, greater sensitivity, and unsurpassed ability to eliminate extraneous electrical "noise", provides an SEMG platform you can use with confidence. With Noromed SEMG you know you are getting true, reliable and repeatable results.In evaluating the technological sophistication, superiority and reliability of SEMG systems, the most important factors are sensitivity (usually expressed in microvolts), the monitoring range (again usually expressed in microvolts), and how the instrument eliminates ambient electrical noise. HCC,KZM,IKN Device, Biofeedback,Device, Muscle Monitoring,Electromyograph, Diagnostic MES 9000 Static Electromyography Scanner
8 D79261451 6145 Duotrodes are silver-silver chloride, bi-polar electrodes for surface EMG applications. IKN Electromyograph, Diagnostic Myotronics 6145 Duotrodes
9 D79240602 4060 Non-jelled TENS Electrodes for use with Myomonitor. Designed for patients with s Non-jelled TENS Electrodes for use with Myomonitor. Designed for patients with sideburns or a beard. NUW Stimulator, Muscle, Powered, Dental 2 Myotrode One With Gel
10 D792N9000M0 N9000M Now you can have all of these capabilities in one compact system. Surface EMG, r Now you can have all of these capabilities in one compact system. Surface EMG, rangeof motion and muscle testing – may be purchased separately or in any combination. The modulardesign of the MES 9000 allows you to purchase any combination of modules and expand as yourpractice grows. The MES 9000 --- the modular system that enables you to do a complete, integratedevaluation with objective documentation that supports your diagnosis. KZM,KQX,HCC Device, Muscle Monitoring,Goniometer, Ac-Powered,Device, Biofeedback MES 9000 Musculoskeletal System
11 D792N9200A0 MES 9000 EMG The Dynamic SEMG module of the MES 9000 allows for the recording of up to 8 chan The Dynamic SEMG module of the MES 9000 allows for the recording of up to 8 channels of SEMG simultaneously. The MES 9000 offers you the flexibility to monitor and record the data in its raw state or as integrated data.The powerful and user-friendly software simplifies the recording of multiple muscle groups of antagonist and synergist muscles to facilitate assessment and case documentation. In addition, the system includes pre-programmed protocols and analysis for assessment, muscle education and relaxation training. The clinician may also program custom protocols - quickly and simply. KZM,HCC,IKN Device, Muscle Monitoring,Device, Biofeedback,Electromyograph, Diagnostic 2 MES 9000 Dynamic EMG
12 D792N36010 NT360 By using sophisticated sensors within the inclinometers, the Dynamic ROM system By using sophisticated sensors within the inclinometers, the Dynamic ROM system records the patient's entire ROM through the plane of movement and displays it in a graphical representation on the computer screen. Unlike other systems which simply give you a static endpoint measurement of ROM, Dynamic ROM captures the entire movement. The figure to your left shows a typical Dynamic ROM recording of the dynamic motion of the spine during three repetitions of lumbar flexion and extension. The numbers correspond with the figure to the left showing the patient's motions.The inclinometers are attached to straps placed over T12 and S1. The recording of the sensor at S1 is subtracted from the recording at T12 to produce the DIFFerential recording graph which represents the true motion of the patient's lumbar during lumbar flexion and extension motion. The flattened DIFF tracing line on each repetition during end-point indicates that both sensors are moving at the same rate of speed, and that the lumbar lordosis stopped unfolding before the end-point of trunk flexion had been reached. With this information the clinician can observe and assess the quality and the pattern of the patient's motion as well as the quantity of the ROM. Dynamic Range of Motion from Noromed elevates range of motion testing from a simple measurement tool to a true diagnostic tool. KQX,HCC Goniometer, Ac-Powered,Device, Biofeedback 1 Noromed NT-360 Inclinometer
13 D792N12011 N120 NOROTRODES are silver-silver chloride electrodes for surface EMG applications. C NOROTRODES are silver-silver chloride electrodes for surface EMG applications. Contact surfaces pre-jelled with hypoallergenic jel that is water soluble for quick cleanup. Mounted on hypoallergenic adhesive. Silver snap connectors. IKN Electromyograph, Diagnostic Norotrode 20
14 D79245000 BNS-40 4500 The BNS-40 is a miniaturized version of the Myomonitor designed to allow the pat The BNS-40 is a miniaturized version of the Myomonitor designed to allow the patient to safely apply electrical stimulation while at home to relax tense muscles. NUW Stimulator, Muscle, Powered, Dental 2 BNS-40 Home Treatment Unit
15 D79243001 4300 36 single-use electrodes per pouch, 2 pouches per box (72 electrodes total).A re 36 single-use electrodes per pouch, 2 pouches per box (72 electrodes total).A revolutionary electrode designed especially for use with the Myomonitor and BNS-40 unit. NUW Stimulator, Muscle, Powered, Dental Myotrode SG Solid Gel TENS Electrodes
16 D79209950 EMG 0995 Utilizing high quality bipolar surface electrodes, surface EMG data can be taken Utilizing high quality bipolar surface electrodes, surface EMG data can be taken from up to eight muscle sites simultaneously and in real time. The program permits taking electromyography data either at rest or in function. All eight channels may be displayed simultaneously, for a period of 15 seconds (one visual screen width). The K7/EMG signal processing circuitry provides unsurpassed protection against system noise or motion artifact. The patient education mode permits quick and easy patient education as to status of masticatory muscles. KZM Device, Muscle Monitoring 2 K7 EMG Electromyograph
17 D79209960 K7 CMS Sensor Array 0996 Multiple sensors in an extremely light weight (four ounce) spectacle-like array, Multiple sensors in an extremely light weight (four ounce) spectacle-like array, track the motion of a tiny magnet attached to the lower incisal gingiva with adhesive material. The configuration is totally non-invasive and, unlike clutches, does not interfere with patient function. The opposing sensors are wide apart permitting unobstructed access to the oral cavity for taking bite registrations and other clinical procedures, and the system is virtually immune from effects of slight head motion or nearby metallic or electronic interference. A patient education mode is included to simplify patient understanding and staff training. NFS Device, Jaw Tracking, For Monitoring Jaw Positions 1 K7 CMS Sensor Array
18 D79209830 ESG-2 0983 TMJ Vibration (Sound) Evaluation System. A lightweight headset holds highly sens TMJ Vibration (Sound) Evaluation System. A lightweight headset holds highly sensitive vibration transducers over each TM joint, enabling simultaneous, bilateral capture of tissue vibrations emanating from joint sounds. Vibration (sound) data is correlated to vertical dimension of opening and closing, providing clinicians with valuable information to aid in assessing the status of articular disk and joint function. NFQ Device, Dental Sonography, For Monitoring Jaw Sounds 1 K7 ESG-2 Electrosonograph
Other products with the same Product Codes "HCC, KZM"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 00890477000296 900-014-2 Insight Discovery Thermal (w/cable) SRS MEDICAL SYSTEMS, INC.
2 00890477000180 900-026 EMG Sensor SRS MEDICAL SYSTEMS, INC.
3 00890477000173 900-023 Insight Discovery PWP (w/cable) SRS MEDICAL SYSTEMS, INC.
4 00890477000166 900-010 Discovery Base Unit SRS MEDICAL SYSTEMS, INC.
5 00890477000159 900-015-2 Insight Discovery Algometer SRS MEDICAL SYSTEMS, INC.
6 00890477000104 900-024-2 Insight Discovery Dual Inclinometer SRS MEDICAL SYSTEMS, INC.
7 00890477000098 900-037 Insight Discovery EMG SRS MEDICAL SYSTEMS, INC.
8 00890477000081 900-036 Insight Discovery PWP SRS MEDICAL SYSTEMS, INC.
9 00890477000074 900-034 Insight Discovery Thermal SRS MEDICAL SYSTEMS, INC.
10 00888912567176 13-8085 VITALSTIM PLUS HAND SWITCH CHATTANOOGA DJO, LLC
11 00888912368926 70004 NEO MODULE STIM CHANNELS 1 & 2 + EMG CHATTANOOGA DJO, LLC
12 00888912294829 2799 EMG MODULE PKG CHATTANOOGA DJO, LLC
13 00888912293334 2772MC INT ADVANCED COMBO MONOCHROMEINT'L STD CHATTANOOGA DJO, LLC
14 00885859004962 MC-200 The Myolab II was specifically designed for use in fitting and troubleshooting t The Myolab II was specifically designed for use in fitting and troubleshooting the Utah Arm and ProPlus myoelectric prostheses. It can be used to locate muscle activity down to 0.2 microvolts in the remnant limb. The adjustable gain feature allows the device to test and train muscle EMG for any single or dual-channel myoelectric control system. MYOLAB II MOTION CONTROL, INC
15 00867606000304 EVO-002-400-000 The eVox System is intended for the acquisition, display, and storage, of electr The eVox System is intended for the acquisition, display, and storage, of electrical activityof a patient’s brain including electroencephalograph (EEG) and event-related potentials(ERP) obtained by placing two or more electrodes on the head to aid in diagnosisThe medical system includes the “eVox System” amplifier device, accessories, and acomputer (laptop computer or tablet device with internal battery and power cord).The hardware and ancillary components used in conjunction with the eVox System includean EEG cap, the eVox Amplifier, a charging kit (that consists of a USB cable, clip kit, andwall adapter), a Subject Response Device and a Base Station laptop computer. Thesoftware on the Base Station laptop computer is intended for device functioning eVox System EVOKE NEUROSCIENCE, INC.
16 00864267000421 PL-21-1000 NeuroEDUCATOR CONTROL BIONICS INCORPORATED
17 00864021000391 D11-D7 D11-D7 Solo Vision Hub with ScanVision Static sEMG Scaners MyoVision Wirefree System PRECISION BIOMETRICS INC
18 00864021000384 D11-D6 D11-D6 Solo Vision Hub with DynaVision Dynamic sEMG MyoVision Wirefree System PRECISION BIOMETRICS INC
19 00864021000377 D11-D5 FlexLite Solo Vision Hub with FlexVision FlexLite Inclinometers MyoVision Wirefree System PRECISION BIOMETRICS INC
20 00864021000360 D11-D5 D11-D5 Solo Vision Hub with FlexVision Inclinometers MyoVision Wirefree System PRECISION BIOMETRICS INC
21 00864021000353 D7 D7 MyoVision ScanVision Static sEMG Scanners PRECISION BIOMETRICS INC
22 00864021000346 D6 D6 MyoVision DynaVision Dynamic sEMG PRECISION BIOMETRICS INC
23 00864021000339 D11 MyoVision SoloVision Hub PRECISION BIOMETRICS INC
24 00864021000322 D5 D5 MyoVision FlexVision Inclinometers PRECISION BIOMETRICS INC
25 00864021000315 D3 D3 MyoVision PhysioMonitor Hub PRECISION BIOMETRICS INC
26 00863712000337 BI2612/BK2613 mTrigger Biofeedback System mTrigger MTRIGGER, LLC
27 00861410000246 1 NA4 nfant® Mobile App NFANT LABS LLC
28 00861410000239 1 NC2-1 nfant® Coupling NFANT LABS LLC
29 00861410000215 1 NS1 nfant® SSB Sensor NFANT LABS LLC
30 00861410000208 1 ND3 nfant® Patient Database NFANT LABS LLC
31 00860001651911 1 SA7525HHS The HindexRV® Monitoring System is a physiological monitoring device that collec The HindexRV® Monitoring System is a physiological monitoring device that collects and transmits measurements (heart rate, respiration rate and muscle activity) using sensors. The HindexRV® monitoring system monitors the sympathetic and parasympathetic nervous system using accurate recordings of heart rate (HR) from EKG and provides statistical data as well as heart rate variability (HRV) data. HindexRV HHS SYSTEMS, INC.
32 00860001651904 1 SA7525HHS The HindexRV® Monitoring System is a physiological monitoring device that collec The HindexRV® Monitoring System is a physiological monitoring device that collects and transmits measurements (heart rate, respiration rate and muscle activity) using sensors. The HindexRV® monitoring system monitors the sympathetic and parasympathetic nervous system using accurate recordings of heart rate (HR) from EKG and provides statistical data as well as heart rate variability (HRV) data. HindexRV HHS SYSTEMS, INC.
33 00860000688611 A10002 A10002 NTrainer System NTrainer INNARA HEALTH, INC.
34 00860000688604 A00002 A00002 NTrainer System NTrainer INNARA HEALTH, INC.
35 00853818007460 D2-D6 D2-D6 VisionHUB with DynaVision Dynamic sEMG MyoVision Wirefree System PRECISION BIOMETRICS INC
36 00853818007453 D2-D5 D2-D5-D5 SERIES-5 VisionHUB with FlexVision Inclinometers SERIES-5 MyoVision FlexVision System PRECISION BIOMETRICS INC
37 00853818007446 D2-D7-D7 D2-D7-D7 SERIES-5 VisionHUB with ScanVision Static sEMG Scanners SERIES-5 MyoVision ScanVision PRECISION BIOMETRICS INC
38 00853818007439 D2-D7 D2-D7 SERIES-5 VisionHUB with ScanVision Static sEMG Scanner SERIES-5 MyoVision ScanVision PRECISION BIOMETRICS INC
39 00853818007422 D2-D5-D6-D7L D2-D5-D6-D7L VisionHub with FlexVision Inclinometers, DynaVision Dynamic sEMG and ScanVision VisionHub with FlexVision Inclinometers, DynaVision Dynamic sEMG and ScanVision Static sEMG Scanner SERIES-5 MyoVision Full System PRECISION BIOMETRICS INC
40 00853818007415 D2-D5-D6 D2-D5-D6 VisionHub with FlexVision Inclinometers and DynaVision Dynamic sEMG MyoVision Wirefree System PRECISION BIOMETRICS INC
41 00853818007392 Feature Pack G Software MyoVision Software PRECISION BIOMETRICS INC
42 00853818007378 PB-220-1 USB Charging Cable for use with ScanVision, FlexVision, ThermoVision USB Charging Cable PRECISION BIOMETRICS INC
43 00853818007354 D3-D5-D6-D7L D3-D5-D6-D7L PhysioMonitor Hub with FlexVision Inclinomters DynaVision Dynamic sEMG and ScanV PhysioMonitor Hub with FlexVision Inclinomters DynaVision Dynamic sEMG and ScanVision Lite Static sEMG Scanner MyoVision Wirefree System PRECISION BIOMETRICS INC
44 00853818007347 D11-D7L D11-D7L Solo Vision Hub with ScanVision Lite Static sEMG Scaner MyoVision Wirefree System PRECISION BIOMETRICS INC
45 00853818007330 PB-205 USB Wall Charger USB Charger PRECISION BIOMETRICS INC
46 00853818007323 PB-202 PB-202 3 ft. USB 2.0 cable for connecting a PhysioMonitor, SoloVision or VisionPort to a computer USB 2.0 Cable (WireFree) PRECISION BIOMETRICS INC
47 00853818007316 PB-225 PB-225 PB-225 Flexlite Charging Cable Flexlite Charging Cable PRECISION BIOMETRICS INC
48 00853818007309 PB-220 PB-220 PB-220 Myovision Charging Cable Myovision Charging Cable PRECISION BIOMETRICS INC
49 00853818007293 PB-204 Power Supply for WireFree System Hubs (WireFree) Power Supply for WireFree PRECISION BIOMETRICS INC
50 00853818007286 PB-40 40" Dynamic Lead Wire Set (WireFree) Dynamic Lead Wire Set PRECISION BIOMETRICS INC