Other products from "SUMMUS MEDICAL LASER, LLC"
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 B679SLP4H0 P4H SLP4H Light weight (~2.5 Kg.) and portable therapeutic medical laser device (measuring Light weight (~2.5 Kg.) and portable therapeutic medical laser device (measuring ~258.65mm x 238.43m x 88.86mm) disc shaped, indicated for temporary relief of minor muscle and joint pain, stiffness, minor arthritis pain, muscle spasm, temporary increase in local blood circulation, and temporary relaxation of muscles by means of topical elevated tissue temperature from infrared spectral emissions. The noninvasive laser treatments (Continuous Wave - CW power 28W and Intense Super Pulse - ISP power 30W) are in the form of non-ionizing radiation in which the invisible light wave doses (810nm +/- 10nm, 915nm +/- 10nm, 980nm +/- 10nm) and visible light wave aiming beam (650nm +/- 20nm) are not cumulative and do not create changes in cellular DNA. The presence of a temperature gradient generates an increased local blood circulation through the tissue to reduce inflammation and pain and to enhance the rate of tissue repair. The laser energy increases circulation, drawing water, oxygen, and nutrients to the target area. The increase in circulation provides a healing environment that reduces inflammation, swelling, muscle spasm, stiffness, and pain. The increased circulation of blood speeds up the process of respiratory cellular activity by stimulating an increase in hemoglobin and nutrients at the target cell and a decrease in cellular carbon dioxide and lactic acid waste. The laser light therapy promotes the transport of nutrients across the cell membrane to aid in the natural repair mechanism of the target cells by stimulating an increase in production of Adenosine Triphosphate (ATP) energy in the cell. The increase in ATP energy and the decrease in waste enhances cellular function and tissue repair. ILY Lamp, Infrared, Therapeutic Heating 2 Platinum
2 B679SLP40 SLP4 SLP4 Light weight (~3 Kg.) and portable therapeutic medical laser device (measuring ~ Light weight (~3 Kg.) and portable therapeutic medical laser device (measuring ~195 mm x 195 mm x 275 mm) indicated for temporary relief of minor muscle and joint pain, stiffness, minor arthritis pain, muscle spasm, temporary increase in local blood circulation, and temporary relaxation of muscles by means of topical elevated tissue temperature from infrared spectral emissions. The noninvasive laser treatments are in the form of non-ionizing radiation in which the invisible light wave doses and visible light wave aiming beam are not cumulative and do not create changes in cellular DNA. The presence of a temperature gradient generates an increased local blood circulation through the tissue to reduce inflammation and pain and to enhance the rate of tissue repair. The laser energy increases circulation, drawing water, oxygen, and nutrients to the target area. The increase in circulation provides a healing environment that reduces inflammation, swelling, muscle spasm, stiffness, and pain. The increased circulation of blood speeds up the process of respiratory cellular activity by stimulating an increase in hemoglobin and nutrients at the target cell and a decrease in cellular carbon dioxide and lactic acid waste. The laser light therapy promotes the transport of nutrients across the cell membrane to aid in the natural repair mechanism of the target cells by stimulating an increase in production of Adenosine Triphosphate (ATP) energy in the cell. The increase in ATP energy and the decrease in waste enhances cellular function and tissue repair. ILY Lamp, Infrared, Therapeutic Heating 2 Platinum
3 B679SLP30 SLP3 SLP3 Light weight (~2 Kg.) and portable therapeutic medical laser device (measuring ~ Light weight (~2 Kg.) and portable therapeutic medical laser device (measuring ~225 mm x 150 mm x 150 mm) indicated for temporary relief of minor muscle and joint pain, stiffness, minor arthritis pain, muscle spasm, temporary increase in local blood circulation, and temporary relaxation of muscles by means of topical elevated tissue temperature from infrared spectral emissions. The noninvasive laser treatments are in the form of non-ionizing radiation in which the invisible light wave doses and visible light wave aiming beam are not cumulative and do not create changes in cellular DNA. The presence of a temperature gradient generates an increased local blood circulation through the tissue to reduce inflammation and pain and to enhance the rate of tissue repair. The laser energy increases circulation, drawing water, oxygen, and nutrients to the target area. The increase in circulation provides a healing environment that reduces inflammation, swelling, muscle spasm, stiffness, and pain. The increased circulation of blood speeds up the process of respiratory cellular activity by stimulating an increase in hemoglobin and nutrients at the target cell and a decrease in cellular carbon dioxide and lactic acid waste. The laser light therapy promotes the transport of nutrients across the cell membrane to aid in the natural repair mechanism of the target cells by stimulating an increase in production of Adenosine Triphosphate (ATP) energy in the cell. The increase in ATP energy and the decrease in waste enhances cellular function and tissue repair. ILY Lamp, Infrared, Therapeutic Heating 2 Platinum
4 B679SLP10 SLP1 SLP1 Light weight (~3 Kg.) and portable therapeutic medical laser device (measuring ~ Light weight (~3 Kg.) and portable therapeutic medical laser device (measuring ~195 mm x 195 mm x 275 mm) indicated for temporary relief of minor muscle and joint pain, stiffness, minor arthritis pain, muscle spasm, temporary increase in local blood circulation, and temporary relaxation of muscles by means of topical elevated tissue temperature from infrared spectral emissions. The noninvasive laser treatments are in the form of non-ionizing radiation in which the invisible light wave doses and visible light wave aiming beam are not cumulative and do not create changes in cellular DNA. The presence of a temperature gradient generates an increased local blood circulation through the tissue to reduce inflammation and pain and to enhance the rate of tissue repair. The laser energy increases circulation, drawing water, oxygen, and nutrients to the target area. The increase in circulation provides a healing environment that reduces inflammation, swelling, muscle spasm, stiffness, and pain. The increased circulation of blood speeds up the process of respiratory cellular activity by stimulating an increase in hemoglobin and nutrients at the target cell and a decrease in cellular carbon dioxide and lactic acid waste. The laser light therapy promotes the transport of nutrients across the cell membrane to aid in the natural repair mechanism of the target cells by stimulating an increase in production of Adenosine Triphosphate (ATP) energy in the cell. The increase in ATP energy and the decrease in waste enhances cellular function and tissue repair. ILY Lamp, Infrared, Therapeutic Heating 2 Platinum
5 B679SLH10 SLH1 SLH1 Light weight (~2 Kg.) and portable therapeutic medical laser device (measuring ~ Light weight (~2 Kg.) and portable therapeutic medical laser device (measuring ~225 mm x 150 mm x 150 mm) indicated for temporary relief of minor muscle and joint pain, stiffness, minor arthritis pain, muscle spasm, temporary increase in local blood circulation, and temporary relaxation of muscles by means of topical elevated tissue temperature from infrared spectral emissions. The noninvasive laser treatments are in the form of non-ionizing radiation in which the invisible light wave doses and visible light wave aiming beam are not cumulative and do not create changes in cellular DNA. The presence of a temperature gradient generates an increased local blood circulation through the tissue to reduce inflammation and pain and to enhance the rate of tissue repair. The laser energy increases circulation, drawing water, oxygen, and nutrients to the target area. The increase in circulation provides a healing environment that reduces inflammation, swelling, muscle spasm, stiffness, and pain. The increased circulation of blood speeds up the process of respiratory cellular activity by stimulating an increase in hemoglobin and nutrients at the target cell and a decrease in cellular carbon dioxide and lactic acid waste. The laser light therapy promotes the transport of nutrients across the cell membrane to aid in the natural repair mechanism of the target cells by stimulating an increase in production of Adenosine Triphosphate (ATP) energy in the cell. The increase in ATP energy and the decrease in waste enhances cellular function and tissue repair. ILY Lamp, Infrared, Therapeutic Heating 2 Platinum
6 B679KP40 KP4 KP4 Therapeutic medical laser device indicated for temporary relief of minor muscle Therapeutic medical laser device indicated for temporary relief of minor muscle and joint pain, stiffness, minor arthritis pain, muscle spasm, temporary increase in local blood circulation, and temporary relaxation of muscles by means of topical elevated tissue temperature from infrared spectral emissions.The noninvasive laser treatments are in the form of non ionizing radiation in which the invisible light wave doses and visible light wave aiming beam are not cumulative and do not create changes in cellular DNA.The presence of a temperature gradient generates an increased local blood circulation through the tissue to reduce inflammation and pain and to enhance the rate of tissue repair.The laser energy increases circulation, drawing water, oxygen, and nutrients to the target area. The increase in circulation provides a healing environment that reduces inflammation, swelling, muscle spasm, stiffness, and pain. The increased circulation of blood speeds up the process of respiratory cellular activity by stimulating an increase in hemoglobin and nutrients at the target cell and a decrease in cellular carbon dioxide and lactic acid waste.The laser light therapy promotes the transport of nutrients across the cell membrane to aid in the natural repair mechanism of the target cells by stimulating an increase in production of Adenosine Triphosphate (ATP) energy in the cell. The increase in ATP energy and the decrease in waste enhances cellular function and tissue repair. ILY Lamp, Infrared, Therapeutic Heating 2 Platinum
7 B679KP30 KP3 KP3 Therapeutic medical laser device indicated for temporary relief of minor muscle Therapeutic medical laser device indicated for temporary relief of minor muscle and joint pain, stiffness, minor arthritis pain, muscle spasm, temporary increase in local blood circulation, and temporary relaxation of muscles by means of topical elevated tissue temperature from infrared spectral emissions.The noninvasive laser treatments are in the form of non ionizing radiation in which the invisible light wave doses and visible light wave aiming beam are not cumulative and do not create changes in cellular DNA.The presence of a temperature gradient generates an increased local blood circulation through the tissue to reduce inflammation and pain and to enhance the rate of tissue repair.The laser energy increases circulation, drawing water, oxygen, and nutrients to the target area. The increase in circulation provides a healing environment that reduces inflammation, swelling, muscle spasm, stiffness, and pain. The increased circulation of blood speeds up the process of respiratory cellular activity by stimulating an increase in hemoglobin and nutrients at the target cell and a decrease in cellular carbon dioxide and lactic acid waste.The laser light therapy promotes the transport of nutrients across the cell membrane to aid in the natural repair mechanism of the target cells by stimulating an increase in production of Adenosine Triphosphate (ATP) energy in the cell. The increase in ATP energy and the decrease in waste enhances cellular function and tissue repair. ILY Lamp, Infrared, Therapeutic Heating 2 Platinum
8 B679KP10 KP1 KP1 Therapeutic medical laser device indicated for temporary relief of minor muscle Therapeutic medical laser device indicated for temporary relief of minor muscle and joint pain, stiffness, minor arthritis pain, muscle spasm, temporary increase in local blood circulation, and temporary relaxation of muscles by means of topical elevated tissue temperature from infrared spectral emissions.The noninvasive laser treatments are in the form of non ionizing radiation in which the invisible light wave doses and visible light wave aiming beam are not cumulative and do not create changes in cellular DNA.The presence of a temperature gradient generates an increased local blood circulation through the tissue to reduce inflammation and pain and to enhance the rate of tissue repair.The laser energy increases circulation, drawing water, oxygen, and nutrients to the target area. The increase in circulation provides a healing environment that reduces inflammation, swelling, muscle spasm, stiffness, and pain. The increased circulation of blood speeds up the process of respiratory cellular activity by stimulating an increase in hemoglobin and nutrients at the target cell and a decrease in cellular carbon dioxide and lactic acid waste.The laser light therapy promotes the transport of nutrients across the cell membrane to aid in the natural repair mechanism of the target cells by stimulating an increase in production of Adenosine Triphosphate (ATP) energy in the cell. The increase in ATP energy and the decrease in waste enhances cellular function and tissue repair. ILY Lamp, Infrared, Therapeutic Heating 2 Platinum
Other products with the same Product Code "ILY"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 00854103007325 PRD-000721-000 BDA Xl Rolling Pin Attachment XL Rolling Pin LITECURE LLC
2 00854103007318 PRD-000644-000 BDA Attachment XL Cone XL Cone LITECURE LLC
3 00854103007288 PRD-000230-000-L BDA Attachment Head Large Cone Large Cone LITECURE LLC
4 00854103007271 PRD-000229-000-L BDA Attachment head Large Ball Large Massage Ball LITECURE LLC
5 00854103007264 PRD-000232-000-L BDA Attachment head Small Cone Small Cone LITECURE LLC
6 00854103007257 PRD-000721-000-L BDA Xl Rolling Pin Attachment XL Rolling Pin LITECURE LLC
7 00854103007240 PRD-000644-000-L BDA Attachment XL Cone XL Cone LITECURE LLC
8 00854103007233 PRD-000233-000-L BDA Attachment head Flat Window Flat Window LITECURE LLC
9 00854103007226 PRD-000231-000-L BDA Attachment head Small Ball Small Massage Ball LITECURE LLC
10 00854103007219 PRD-000230-010-L BDA Attachment Head Large Cone Large Cone LITECURE LLC
11 00854103007202 PRD-000229-010-00-L BDA Attachment head Large Ball Large Massage Ball LITECURE LLC
12 00854103007196 PRD-000477-000-04-L Legacy Hand Piece 600um Fiber Hand Piece w/ Finger Switch, Dark Gray Empower Delivery System LITECURE LLC
13 00854103007189 PRD-000477-000-03-L Legacy Hand Piece 600um Fiber Hand Piece w/ Finger Switch, Cool Gray Empower Delivery System LITECURE LLC
14 00854103007172 PRD-000477-000-02-L Legacy Hand Piece 800um Fiber Hand Piece w/ Finger Switch, Dark Gray Empower Delivery System LITECURE LLC
15 00854103007165 PRD-000477-000-01-L Legacy Hand Piece 800um Fiber Hand Piece w/ Finger Switch, Cool Gray Empower Delivery System LITECURE LLC
16 00854103007134 PRD-000758-010-00-L Smart Hand Piece (SHP)_800um Fiber Assy v2 Empower IQ Delivery System LITECURE LLC
17 00854103007110 PRD-000424-010-01-L Basic Hand Piece (BHP)_600um Fiber Assy (White) Empower Delivery System LITECURE LLC
18 00854103007103 LTS-2500-L-S8 Mains powered, infrared phototherapy device emitting up to 25 W at 980/810nm in Mains powered, infrared phototherapy device emitting up to 25 W at 980/810nm in CW or pulsed modes with a 10" touch screen display. Compatible with New Empower IQ delivery system. LightForce XPi LITECURE LLC
19 00854103007097 LTC-1510-L-B6 Infrared phototherapy device emitting up to 15 W at 980/810nm in CW or pulsed m Infrared phototherapy device emitting up to 15 W at 980/810nm in CW or pulsed modes. The device can be powered through its battery pack or mains power and has a 10" touch-screen display. Compatible with new empower delivery system with integrated emission control button and LED indicator. LightForce FXi LITECURE LLC
20 00854103007073 LTS-4000-L The LightForce XLi is a professional musculoskeletal/physical therapy laser emit The LightForce XLi is a professional musculoskeletal/physical therapy laser emitting up to 40W at 810/980nm wavelengths. The LightForce XLi is indicated for emitting energy in the visible and near infrared spectrum to provide topical heating for the purpose of elevating tissue temperature for a temporary relief of minor muscle and joint pain and stiffness, minor arthritis pain, or muscle spasm; the temporary increase in local blood circulation; and the temporary relaxation of muscle. The XLi laser system includes a therapeutic laser console and optical delivery system. The optical delivery system consists of a flexible optical fiber connected to a hand piece with interchangeable treatment heads and provides motion feedback to the user. A custom software application allows the user to select from built-in treatment protocols that adjust dosage and wavelength based on patient characteristics and condition. The device also provides the ability to set custom treatment parameters including output power, treatment time, and pulse rate. LightForce XLi LITECURE LLC
21 00854103007066 LTC-1510-SOLA Infrared phototherapy device emitting up to 8W at 810/980nm, battery option, 10" display SoLa Therapy Laser LITECURE LLC
22 00854103007059 LTS-2500 Mains powered, infrared phototherapy and nail laser phototherapy device emitting Mains powered, infrared phototherapy and nail laser phototherapy device emitting up to 25 W at 980/810nm in CW or pulsed modes with a 10" touch screen display. LightForce EXPi LITECURE LLC
23 00854103007042 LTC-1500 Infrared phototherapy device emitting up to 15 W at 980/810nm in CW or pulsed mo Infrared phototherapy device emitting up to 15 W at 980/810nm in CW or pulsed modes. The device can be powered through its battery pack or mains power and has a 10" touch-screen display. LightForce FXi LITECURE LLC
24 00854103007035 LTS-1500P Mains powered, infrared and nail laser phototherapy device emitting up to 15 W a Mains powered, infrared and nail laser phototherapy device emitting up to 15 W at 810 & 980 nm and up to 25 W at 980 nm. At 810 & 980 nm, the LightForce EXP (LTS-1500P) is indicated for emitting energy in the infrared spectrum to provide topical heating for the purpose of elevating tissue temperature for temporary relief of minor muscle and joint pain, muscle spasm, pain and stiffness associated with arthritis and promoting relaxation of the muscle tissue and to temporarily increase local blood circulation. At 980 nm, the EXP is indicated for use for the temporary increase of clear nail in patients with onychomycosis (e.g. dermatophytes, Trichophyton rubrum and Tmentagrophytes, and/or yeasts Candida albicans, etc.). The EXP is a portable medical laser therapy system. The laser light delivery system consists of a flexible optical fiber threaded through a lightweight hand piece. Activation occurs when the operator enables the laser and presses the finger switch, or optional foot switch. Depending on laser system configuration, the finger switch can function as an on/off switch. A touch-screen display panel allows the operator to adjust or set laser output level. The laser can operate in continuous wave mode or controlled pulse mode. LightForce EXP LITECURE LLC
25 00854103007028 LTS-1500 Mains powered, Infrared phototherapy device emitting up to 15 W at 810 & 980 nm. Mains powered, Infrared phototherapy device emitting up to 15 W at 810 & 980 nm. The LightForce EX (LTS-1500) is indicated for emitting energy in the infrared spectrum to provide topical heating for the purpose of elevating tissue temperature for temporary relief of minor muscle and joint pain, muscle spasm, pain and stiffness associated with arthritis and promoting relaxation of the muscle tissue and to temporarily increase local blood circulation. The EX is a portable medical laser therapy system. The laser light delivery system consists of a flexible optical fiber threaded through a lightweight hand piece. Activation occurs when the operator enables the laser and presses the finger switch, or optional foot switch. Depending on laser system configuration, the finger switch can function as an on/off switch. A touch-screen display panel allows the operator to adjust or set laser output level. The laser can operate in continuous wave mode or controlled pulse mode. LightForce EX LITECURE LLC
26 00854103007011 LTC-1500 Infrared phototherapy device emitting up to 15 W at 980 & 810 nm. The device ca Infrared phototherapy device emitting up to 15 W at 980 & 810 nm. The device can be powered through its battery pack or mains power. The LightForce FX (LTC-1500) is indicated for emitting energy in the infrared spectrum to provide topical heating for the purpose of elevating tissue temperature for temporary relief of minor muscle and joint pain, muscle spasm, pain and stiffness associated with arthritis and promoting. relaxation of the muscle tissue and to temporarily increase local blood circulation. The FX is a compact, portable, and mobile medical laser therapy system. The laser light delivery system consists of a flexible optical fiber threaded through a lightweight hand piece. Activation occurs when the operator enables the laser and presses the finger switch, or optional foot switch. Depending on laser system configuration, the finger switch can function as an on/off switch. A touch-screen display panel allows the operator to adjust or set laser output level. The laser can operate in continuous wave mode or controlled pulse mode. LightForce FX LITECURE LLC
27 00854103007004 LTC-900 Mains powered, infrared phototherapy device emitting up to 9 W at 980 nm. The Mains powered, infrared phototherapy device emitting up to 9 W at 980 nm. The LightForce PRO (LTC-900) is indicated for emitting energy in the infrared spectrum to provide topical heating for the purpose of elevating tissue temperature for temporary relief of minor muscle and joint pain, muscle spasm, pain and stiffness associated with arthritis and promoting. relaxation of the muscle tissue and to temporarily increase local blood circulation. The PRO is a compact, portable medical laser therapy system. The laser light delivery system consists of a flexible optical fiber threaded through a lightweight hand piece. Activation occurs when the operator enables the laser and presses the finger switch. Depending on laser system configuration, the finger switch can function as an on/off switch. A touch-screen display panel allows the operator to adjust or set laser output level. The laser can operate in continuous wave mode or controlled pulse mode. LightForce PRO LITECURE LLC
28 00852753008969 Handheld, HH Apollo laser handheld Apollo PIVOTAL HEALTH SOLUTIONS, INC.
29 00852753008891 Portable, AP2-PT Apollo portable laser system Apollo PIVOTAL HEALTH SOLUTIONS, INC.
30 00852753008884 Desktop AP2-DT Desktop laser Apollo PIVOTAL HEALTH SOLUTIONS, INC.
31 00852556007343 PainAway Home Care 600-204 PainAway MULTI RADIANCE MEDICAL
32 00852556007336 PainAway 600-200 PainAway MULTI RADIANCE MEDICAL
33 00852556007329 MR5 Activ Pro LaserStim G U600-408G MR5 MULTI RADIANCE MEDICAL
34 00852556007312 MR5 Activ Pro G U600-400G MR5 MULTI RADIANCE MEDICAL
35 00852556007305 MR5 Activ Pro Laser Shower G U600-500G MR5 MULTI RADIANCE MEDICAL
36 00852556007299 PainAway U800-100 Painaway MULTI RADIANCE MEDICAL
37 00852556007282 PainAway Homecare U800-305 Painaway MULTI RADIANCE MEDICAL
38 00852556007275 MR5 Activ Pro Laser Shower U600-500 MR5 MULTI RADIANCE MEDICAL
39 00852556007268 TQ Solo Laser U800-300K TerraQuant MULTI RADIANCE MEDICAL
40 00852556007251 MR5 Activ Pro LaserStim U600-408 MR5 MULTI RADIANCE MEDICAL
41 00852556007244 MR5 Activ Pro U600-400 MR5 MULTI RADIANCE MEDICAL
42 00852556007220 MR4 LaserShower 50 4-D Emitter G 650-114G MR4 MULTI RADIANCE MEDICAL
43 00852556007213 MR4 LaserStim Emitter G 650-108G MR4 MULTI RADIANCE MEDICAL
44 00852556007206 MR4 Super Pulsed Laser Console G 600G MR4 MULTI RADIANCE MEDICAL
45 00852556007190 Gameday Laser G U300-200G GameDay MULTI RADIANCE MEDICAL
46 00852556007183 MR4 Activ G U600-300G MR4 MULTI RADIANCE MEDICAL
47 00852556007176 MR4 Laser System G U600G MR4 MULTI RADIANCE MEDICAL
48 00852556007169 TruDenta Laser System U801 TruDenta MULTI RADIANCE MEDICAL
49 00852556007152 TQ LaserShower 50 4-D Emitter 850-114 TerraQuant MULTI RADIANCE MEDICAL
50 00852556007145 TQ SE25 Standard Emitter 850-113 TerraQuant MULTI RADIANCE MEDICAL