Duns Number:064039514
Device Description: The Non-Activated Clotting Test Kit contains the necessary components for an in vitro diag The Non-Activated Clotting Test Kit contains the necessary components for an in vitro diagnostic test for use with the Sonoclot® Coagulation & Platelet Function Analyzer System. It may be used with native whole blood, citrated whole blood, and plasma. The Non-Activated Kit may either be used as a non-activated clotting test or as a general use test with user provided activators. It is intended for customer designed hemostasis monitoring on the Sonoclot Analyzer. The Non-Activated cuvette allows for coagulation monitoring using tissue activation, thrombin activation, and other custom activators. Some of the applications for the Non-Activated test with the addition of customer determined reagents are monitoring of fibrin formation, fibrinolysis, hyperfibrinolysis and clot retraction. When used with the Sonoclot Analyzer System, the Non-Activated test provides quantitative Onset/ACT and Clot Rate results as well as qualitative and quantitative information on the Sonoclot Signature including: fibrin formation, platelet function, and hyperfibrinolysis. Each kit contains 24 lidded plastic cuvettes, 24 probes, and instructions for use. The cuvettes contain a magnetic stir bar.
Catalog Number
800-0426
Brand Name
Sonoclot® NonActivated Kit
Version/Model Number
800-0426
Device Commercial Distribution Status
In Commercial Distribution
Commercial Distribution End Date
-
Issuing Agency
In HIBCC
MRI safety Status
Labeling does not contain MRI Safety Information
Device required to be labeled as containing natural rubber latex or dry natural rubber (21 CFR 801.437)
-
Device labeled as "Not made with natural rubber latex"
-
For Single-Use
Yes
Prescription Use (Rx)
-
Over the Counter (OTC)
-
Kit
-
Combination Product
-
Human Cell, Tissue or Cellular or Tissue-Based Product (HCT/P)
-
FDA Premarket Submission
K952560,K952560
Product Code
JPA
Product Code Name
System, Multipurpose For In Vitro Coagulation Studies
Public Device Record Key
638534ac-4a42-414e-b1c4-5201f6bc5316
Public Version Date
July 27, 2021
Public Version Number
1
DI Record Publish Date
July 19, 2021
Package DI Number
None
Quantity per Package
-
Contains DI Package
-
Package Discontinue Date
-
Package Status
-
Package Type
-
Device Class | Device Class Description | No of Devices |
---|---|---|
2 | A medical device with a moderate to high risk that requires special controls. | 11 |