Other products from "MEDIAID INC"
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 B425FMC6469 FMC6469 FMC6469 Thermometer FLL Thermometer, Electronic, Clinical 2 Faichney Medical Company
2 B425POX0209502 POX020-950 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Adhesive Disposable sensor with Micro Foam Tape - Adult
3 B425CST100316292 CST100-31629 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Reusable Sensor - Soft Adult
4 B425CST100313092 CST100-31309 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Reusable Sensor - Soft Adult
5 B425CST10031302 CST100-3130 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Reusable Sensor - Soft Adult
6 B425CST100312692 CST100-31269 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Reusable Sensor - Soft Adult
7 B425CST10031262 CST100-3126 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Reusable Sensor - Soft Adult
8 B425CST100312592 CST100-31259 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Reusable Sensor - Soft Adult
9 B425CST10031252 CST100-3125 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Reusable Sensor - Soft Adult
10 B425CST100312092 CST100-31209 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Reusable Sensor - Soft Adult
11 B425CST10031202 CST100-3120 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Reusable Sensor - Soft Adult
12 B425CST100310792 CST100-31079 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Reusable Sensor - Soft Adult
13 B425CST10031072 CST100-3107 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Reusable Sensor - Soft Adult
14 B425CST100310692 CST100-31069 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Reusable Sensor - Soft Adult
15 B425CST10031062 CST100-3106 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Reusable Sensor - Soft Adult
16 B425CST100310492 CST100-31049 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Reusable Sensor - Soft Adult
17 B425CST1003102 CST100-3104 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Reusable Sensor - Soft Adult
18 B425CST05029642 CST050-2964 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Non-adhesive Disposable sensor with Velcro Tape - Neonatal
19 B425CST05029542 CST050-2954 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Non-adhesive Disposable sensor with Velcro Tape - Neonatal
20 B425CST05029042 CST050-2904 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Non-adhesive Disposable sensor with Velcro Tape - Neonatal
21 B425CST05027042 CST050-2704 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Non-adhesive Disposable sensor with Velcro Tape - Neonatal
22 B425CST05026042 CST050-2604 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Non-adhesive Disposable sensor with Velcro Tape - Neonatal
23 B425CST05024042 CST050-2404 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Non-adhesive Disposable sensor with Velcro Tape - Neonatal
24 B425CST05023042 CST050-2304 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Non-adhesive Disposable sensor with Velcro Tape - Neonatal
25 B425CST05021242 CST050-2124 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Non-adhesive Disposable sensor with Velcro Tape - Neonatal
26 B425CST03229622 CST032-2962 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Adhesive Disposable Sensors with Transpore Tape - Pediatric
27 B425CST03229522 CST032-2952 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Adhesive Disposable Sensors with Transpore Tape - Pediatric
28 B425CST03229022 CST032-2902 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Adhesive Disposable Sensors with Transpore Tape - Pediatric
29 B425CST03227022 CST032-2702 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Adhesive Disposable Sensors with Transpore Tape - Pediatric
30 B425CST03226022 CST032-2602 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Adhesive Disposable Sensors with Transpore Tape - Pediatric
31 B425CST03224022 CST032-2402 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Adhesive Disposable Sensors with Transpore Tape - Pediatric
32 B425CST03223022 CST032-2302 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Adhesive Disposable Sensors with Transpore Tape - Pediatric
33 B425CST03221222 CST032-2122 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Adhesive Disposable Sensors with Transpore Tape - Pediatric
34 B425CST102316292 CST102-31629 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Reusable Sensor - Soft Pedi
35 B425CST10231622 CST102-3162 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Reusable Sensor - Soft Pedi
36 B425CST102313092 CST102-31309 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Reusable Sensor - Soft Pedi
37 B425CST10231302 CST102-3130 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Reusable Sensor - Soft Pedi
38 B425CST102312692 CST102-31269 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Reusable Sensor - Soft Pedi
39 B425CST10231262 CST102-3126 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Reusable Sensor - Soft Pedi
40 B425CST102312592 CST102-31259 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Reusable Sensors - Soft Pedi
41 B425CST10231252 CST102-3125 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Reusable Sensor - Soft Pedi
42 B425CST102312092 CST102-31209 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Reusable Sensor - Soft Pedi
43 B425CST10231202 CST102-3120 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Reusable Sensor - Soft Pedi
44 B425CST102310792 CST102-31079 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Reusable Sensor - Soft Pedi
45 B425CST10231072 CST102-3107 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Reusable Sensor - Soft Pedi
46 B425CST102310692 CST102-31069 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Reusable Sensor - Soft Pedi
47 B425CST10231062 CST102-3106 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Reusable Sensor - Soft Pedi
48 B425CST102310492 CST102-31049 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Reusable Sensor - Soft Pedi
49 B425CST10231042 CST102-3104 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Reusable Sensor - Soft Pedi
50 B425CST060310492 CST060-31049 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. DQA Oximeter 2 Reusable Sensors - Adult Finger
Other products with the same Product Code "DQA"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 00840117310223 36402 Pulse Oximeter, Pediatric Pulse Oximeter DYNAREX CORPORATION
2 00840117310162 36400 Pulse Oximeter Pulse Oximeter DYNAREX CORPORATION
3 00840067103951 302560-200-0000 Oximetry Tape for Nonin 8000J Cadwell CADWELL INDUSTRIES, INC.
4 00840067103616 199306-200 Iomax Earphone Insert Cable Cascade IOMAX CADWELL INDUSTRIES, INC.
5 00840067102862 362061-000 LOW CURRENT INTERFACE CABLE Cascade IOMAX CADWELL INDUSTRIES, INC.
6 00840067102831 199291-200 IOMAX EARPHONE INSERT CABLE Cascade IOMAX CADWELL INDUSTRIES, INC.
7 00840067102763 190309-200 IOMAX 32 Channel Amplifier Cascade IOMAX Intraoperative Monitor CADWELL INDUSTRIES, INC.
8 00840067102718 199305-200 IOMAX 3M VEP LED GOGGLES Cascade IOMAX Intraoperative Monitor CADWELL INDUSTRIES, INC.
9 00840067102688 362072-000 16 Channel Amplifier Input Adapter IOMAX Adapter CADWELL INDUSTRIES, INC.
10 00840067102671 362071-000 16 Channel Input Extender IOMAX Extender Pod CADWELL INDUSTRIES, INC.
11 00840067102664 362069-000 TCS-9 Output Adapter IOMAX Adapter CADWELL INDUSTRIES, INC.
12 00840067102657 362068-000 TCS-9 Output Extender IOMAX Extender Pod CADWELL INDUSTRIES, INC.
13 00840067102244 197278-000 Disposable Goggle Foam, 10pk Cadwell Disposable Goggle Foam CADWELL INDUSTRIES, INC.
14 00840067102220 190299-200 LCSwap IOMAX Cascade IOMAX Intraoperative Monitor CADWELL INDUSTRIES, INC.
15 00840067102053 199289-200 Cascade IOMAX VEP LED Goggles Cascade IOMAX CADWELL INDUSTRIES, INC.
16 00840067100653 190296-200 Cascade IOMAX Cortical Module Cascade IOMAX Intraoperative Monitor CADWELL INDUSTRIES, INC.
17 00840067100646 190295-200 Cascade IOMAX Limb Module Cascade IOMAX Intraoperative Monitor CADWELL INDUSTRIES, INC.
18 00840067100639 190291-200 Cascade IOMAX Base Module Cascade IOMAX Intraoperative Monitor CADWELL INDUSTRIES, INC.
19 00840067100615 198232-200 Oximeter, USB 3012LP Arc Essentia CADWELL INDUSTRIES, INC.
20 00840067100493 190211-200 EasyNet SpO2 EasyNet CADWELL INDUSTRIES, INC.
21 00833166000627 8000JFW Flexiwrap Nonin NONIN MEDICAL, INC.
22 00833166001082 UNI-RA-0 Universal Cable, Right Angle Nonin NONIN MEDICAL, INC.
23 00833166001075 UNI-EXT-9 Universal Extension cable Nonin NONIN MEDICAL, INC.
24 00833166001068 UNI-EXT-6 Universal Extension Cable Nonin NONIN MEDICAL, INC.
25 00833166001051 UNI-EXT-3 Universal Extension cable Nonin NONIN MEDICAL, INC.
26 00833166000818 8000TW Toe Wrap Nonin NONIN MEDICAL, INC.
27 00833166000795 8000FW Finger Wrap Nonin NONIN MEDICAL, INC.
28 00833166000658 3100I Adapter Cable Nonin NONIN MEDICAL, INC.
29 00833166000641 8008JFW Flexiwrap Nonin NONIN MEDICAL, INC.
30 00833166000634 8001JFW Neonatal FlexiWrap® Single Use Sensor Wrap Nonin NONIN MEDICAL, INC.
31 00833166009798 7500 Tabletop Pulse Oximeter Nonin NONIN MEDICAL, INC.
32 00833166009262 Lanyard. GO2 Lanyard Nonin NONIN MEDICAL, INC.
33 00833166009040 9600NC-6 Nurse Call Cable Nonin NONIN MEDICAL, INC.
34 00833166009033 9600NC-10 Nurse Call Cable Nonin NONIN MEDICAL, INC.
35 00833166009026 9600NC-10X Nurse Call Cable Nonin NONIN MEDICAL, INC.
36 00833166008838 LS1 PS Power Supply, LS1 Nonin NONIN MEDICAL, INC.
37 00833166008241 NCell N Cell Battery Nonin NONIN MEDICAL, INC.
38 00833166008227 UNI-RA-0 Universal Cable, Right Angle Nonin NONIN MEDICAL, INC.
39 00833166007558 7500PS Power Supply for use with Model 7500 Nonin NONIN MEDICAL, INC.
40 00833166007206 9500 Lanyard & lock Nonin NONIN MEDICAL, INC.
41 00833166004786 3100I-DS Interface Cable Nonin NONIN MEDICAL, INC.
42 00833166004557 8000AA-1 Adult Articulated Clip Sensor, Reusable, Respironics Nonin NONIN MEDICAL, INC.
43 00833166004120 3150IW Interface Cable Nonin NONIN MEDICAL, INC.
44 00833166004113 3150SC Serial Cable, WristOx2 Nonin NONIN MEDICAL, INC.
45 00833166004083 6500MA Single-Patient Use, Disposable Pulse Oximeter Sensor Nonin NONIN MEDICAL, INC.
46 00833166003932 Pole Mount Clamp Pole Mount Clamp Nonin NONIN MEDICAL, INC.
47 00833166003475 3150I Interface Cable Nonin NONIN MEDICAL, INC.
48 00833166002140 X-100EC-1 1 Meter Extension Cable Nonin NONIN MEDICAL, INC.
49 00833166001303 3150 Wrist Strap Nonin NONIN MEDICAL, INC.
50 00833166001259 3013FH Xpod LP with 600CA, 7000A for use with GE Apex Pro FH Nonin NONIN MEDICAL, INC.