Other products from "MEDITECH SPINE, LLC"
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 B167322618110 3-22618-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
2 B167322617110 3-22617-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
3 B167322616110 3-22616-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
4 B167322615110 3-22615-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
5 B167322614110 3-22614-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
6 B167322613110 3-22613-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
7 B167322612110 3-22612-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
8 B167322611110 3-22611-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
9 B167322610110 3-22610-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
10 B167322609110 3-22609-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
11 B167322608110 3-22608-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
12 B167322518110 3-22518-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
13 B167322517110 3-22517-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
14 B167322516110 3-22516-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
15 B167322515110 3-22515-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
16 B167322514110 3-22514-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
17 B167322513110 3-22513-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
18 B167322512110 3-22512-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
19 B167322511110 3-22511-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
20 B167322510110 3-22510-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
21 B167322509110 3-22509-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
22 B167322508110 3-22508-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
23 B167322418110 3-22418-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
24 B167322417110 3-22417-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
25 B167322416110 3-22416-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
26 B167322415110 3-22415-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
27 B167322414110 3-22414-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
28 B167322413110 3-22413-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
29 B167322412110 3-22412-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
30 B167322411110 3-22411-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
31 B167322410110 3-22410-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
32 B167322409110 3-22409-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
33 B167322408110 3-22408-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
34 B167322318110 3-22318-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
35 B167322317110 3-22317-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
36 B167322316110 3-22316-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
37 B167322315110 3-22315-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
38 B167322314110 3-22314-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
39 B167322313110 3-22313-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
40 B167322312110 3-22312-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
41 B167322311110 3-22311-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
42 B167322310110 3-22310-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
43 B167322309110 3-22309-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
44 B167322308110 3-22308-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
45 B167322218110 3-22218-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
46 B167322217110 3-22217-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
47 B167322216110 3-22216-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
48 B167322215110 3-22215-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
49 B167322214110 3-22214-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
50 B167322213110 3-22213-11 MAX Intervertebral fusion device with bone graft, lumbar 2 TALOS® HA PEEK IBF
Other products with the same Product Code "KWQ"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 90814008025537 ALB-60L-35 Buttress Plate Screw 35mm long, 6.0mm circumference, locking. The Boundary Ante Buttress Plate Screw 35mm long, 6.0mm circumference, locking. The Boundary Anterior Lumbar Buttress Plate is intended to stabilize the allograft or autograft at one level (L1-S1) as an aid to spinal fusion and to provide temporary stabilization and augment development of a solid spinal fusion. It may be used alone or with other anterior, anterolateral, or posterior spinal systems made of compatible materials. This device is not intended for load bearing applications. Boundary NVISION BIOMEDICAL TECHNOLOGIES, INC.
2 90814008025520 ALB-60L-30 Buttress Plate Screw 30mm long, 6.0mm circumference, locking. The Boundary Ante Buttress Plate Screw 30mm long, 6.0mm circumference, locking. The Boundary Anterior Lumbar Buttress Plate is intended to stabilize the allograft or autograft at one level (L1-S1) as an aid to spinal fusion and to provide temporary stabilization and augment development of a solid spinal fusion. It may be used alone or with other anterior, anterolateral, or posterior spinal systems made of compatible materials. This device is not intended for load bearing applications. Boundary NVISION BIOMEDICAL TECHNOLOGIES, INC.
3 90814008025513 ALB-60L-25 Buttress Plate Screw 25mm long, 6.0mm circumference, locking. The Boundary Ante Buttress Plate Screw 25mm long, 6.0mm circumference, locking. The Boundary Anterior Lumbar Buttress Plate is intended to stabilize the allograft or autograft at one level (L1-S1) as an aid to spinal fusion and to provide temporary stabilization and augment development of a solid spinal fusion. It may be used alone or with other anterior, anterolateral, or posterior spinal systems made of compatible materials. This device is not intended for load bearing applications. Boundary NVISION BIOMEDICAL TECHNOLOGIES, INC.
4 90814008025506 ALB-60L-20 Buttress Plate Screw 20mm long, 6.0mm circumference, locking. The Boundary Ante Buttress Plate Screw 20mm long, 6.0mm circumference, locking. The Boundary Anterior Lumbar Buttress Plate is intended to stabilize the allograft or autograft at one level (L1-S1) as an aid to spinal fusion and to provide temporary stabilization and augment development of a solid spinal fusion. It may be used alone or with other anterior, anterolateral, or posterior spinal systems made of compatible materials. This device is not intended for load bearing applications. Boundary NVISION BIOMEDICAL TECHNOLOGIES, INC.
5 90814008025490 ALB-60S-35 Buttress Plate Screw 35mm long, 6.0mm circumference, non-locking. The Boundary Buttress Plate Screw 35mm long, 6.0mm circumference, non-locking. The Boundary Anterior Lumbar Buttress Plate is intended to stabilize the allograft or autograft at one level (L1-S1) as an aid to spinal fusion and to provide temporary stabilization and augment development of a solid spinal fusion. It may be used alone or with other anterior, anterolateral, or posterior spinal systems made of compatible materials. This device is not intended for load bearing applications. Boundary NVISION BIOMEDICAL TECHNOLOGIES, INC.
6 90814008025483 ALB-60S-30 Buttress Plate Screw 30mm long, 6.0mm circumference, non-locking. The Boundary Buttress Plate Screw 30mm long, 6.0mm circumference, non-locking. The Boundary Anterior Lumbar Buttress Plate is intended to stabilize the allograft or autograft at one level (L1-S1) as an aid to spinal fusion and to provide temporary stabilization and augment development of a solid spinal fusion. It may be used alone or with other anterior, anterolateral, or posterior spinal systems made of compatible materials. This device is not intended for load bearing applications. Boundary NVISION BIOMEDICAL TECHNOLOGIES, INC.
7 90814008025476 ALB-60S-25 Buttress Plate Screw 25mm long, 6.0mm circumference, non-locking. The Boundary Buttress Plate Screw 25mm long, 6.0mm circumference, non-locking. The Boundary Anterior Lumbar Buttress Plate is intended to stabilize the allograft or autograft at one level (L1-S1) as an aid to spinal fusion and to provide temporary stabilization and augment development of a solid spinal fusion. It may be used alone or with other anterior, anterolateral, or posterior spinal systems made of compatible materials. This device is not intended for load bearing applications. Boundary NVISION BIOMEDICAL TECHNOLOGIES, INC.
8 90814008025469 ALB-60S-20 Buttress Plate Screw 20mm long, 6.0mm circumference, non-locking. The Boundary Buttress Plate Screw 20mm long, 6.0mm circumference, non-locking. The Boundary Anterior Lumbar Buttress Plate is intended to stabilize the allograft or autograft at one level (L1-S1) as an aid to spinal fusion and to provide temporary stabilization and augment development of a solid spinal fusion. It may be used alone or with other anterior, anterolateral, or posterior spinal systems made of compatible materials. This device is not intended for load bearing applications. Boundary NVISION BIOMEDICAL TECHNOLOGIES, INC.
9 90814008025452 ALB-55L-35 Buttress Plate Screw 35mm long, 5.5mm circumference, locking. The Boundary Ante Buttress Plate Screw 35mm long, 5.5mm circumference, locking. The Boundary Anterior Lumbar Buttress Plate is intended to stabilize the allograft or autograft at one level (L1-S1) as an aid to spinal fusion and to provide temporary stabilization and augment development of a solid spinal fusion. It may be used alone or with other anterior, anterolateral, or posterior spinal systems made of compatible materials. This device is not intended for load bearing applications. Boundary NVISION BIOMEDICAL TECHNOLOGIES, INC.
10 90814008025445 ALB-55L-30 Buttress Plate Screw 30mm long, 5.5mm circumference, locking. The Boundary Ante Buttress Plate Screw 30mm long, 5.5mm circumference, locking. The Boundary Anterior Lumbar Buttress Plate is intended to stabilize the allograft or autograft at one level (L1-S1) as an aid to spinal fusion and to provide temporary stabilization and augment development of a solid spinal fusion. It may be used alone or with other anterior, anterolateral, or posterior spinal systems made of compatible materials. This device is not intended for load bearing applications. Boundary NVISION BIOMEDICAL TECHNOLOGIES, INC.
11 90814008025438 ALB-55L-25 Buttress Plate Screw 25mm long, 5.5mm circumference, locking. The Boundary Ante Buttress Plate Screw 25mm long, 5.5mm circumference, locking. The Boundary Anterior Lumbar Buttress Plate is intended to stabilize the allograft or autograft at one level (L1-S1) as an aid to spinal fusion and to provide temporary stabilization and augment development of a solid spinal fusion. It may be used alone or with other anterior, anterolateral, or posterior spinal systems made of compatible materials. This device is not intended for load bearing applications. Boundary NVISION BIOMEDICAL TECHNOLOGIES, INC.
12 90814008025421 ALB-55L-20 Buttress Plate Screw 20mm long, 5.5mm circumference, locking. The Boundary Ante Buttress Plate Screw 20mm long, 5.5mm circumference, locking. The Boundary Anterior Lumbar Buttress Plate is intended to stabilize the allograft or autograft at one level (L1-S1) as an aid to spinal fusion and to provide temporary stabilization and augment development of a solid spinal fusion. It may be used alone or with other anterior, anterolateral, or posterior spinal systems made of compatible materials. This device is not intended for load bearing applications. Boundary NVISION BIOMEDICAL TECHNOLOGIES, INC.
13 90814008025414 ALB-55S-35 Buttress Plate Screw 35mm long, 5.5mm circumference, non locking. The Boundary Buttress Plate Screw 35mm long, 5.5mm circumference, non locking. The Boundary Anterior Lumbar Buttress Plate is intended to stabilize the allograft or autograft at one level (L1-S1) as an aid to spinal fusion and to provide temporary stabilization and augment development of a solid spinal fusion. It may be used alone or with other anterior, anterolateral, or posterior spinal systems made of compatible materials. This device is not intended for load bearing applications. Boundary NVISION BIOMEDICAL TECHNOLOGIES, INC.
14 90814008025407 ALB-55S-30 Buttress Plate Screw 30mm long, 5.5mm circumference, non locking. The Boundary Buttress Plate Screw 30mm long, 5.5mm circumference, non locking. The Boundary Anterior Lumbar Buttress Plate is intended to stabilize the allograft or autograft at one level (L1-S1) as an aid to spinal fusion and to provide temporary stabilization and augment development of a solid spinal fusion. It may be used alone or with other anterior, anterolateral, or posterior spinal systems made of compatible materials. This device is not intended for load bearing applications. Boundary NVISION BIOMEDICAL TECHNOLOGIES, INC.
15 90814008025391 ALB-55S-25 Buttress Plate Screw 25mm long, 5.5mm circumference, non locking. The Boundary Buttress Plate Screw 25mm long, 5.5mm circumference, non locking. The Boundary Anterior Lumbar Buttress Plate is intended to stabilize the allograft or autograft at one level (L1-S1) as an aid to spinal fusion and to provide temporary stabilization and augment development of a solid spinal fusion. It may be used alone or with other anterior, anterolateral, or posterior spinal systems made of compatible materials. This device is not intended for load bearing applications. Boundary NVISION BIOMEDICAL TECHNOLOGIES, INC.
16 90814008025384 ALB-55S-20 Buttress Plate Screw 20mm long, 5.5mm circumference, non locking. The Boundary Buttress Plate Screw 20mm long, 5.5mm circumference, non locking. The Boundary Anterior Lumbar Buttress Plate is intended to stabilize the allograft or autograft at one level (L1-S1) as an aid to spinal fusion and to provide temporary stabilization and augment development of a solid spinal fusion. It may be used alone or with other anterior, anterolateral, or posterior spinal systems made of compatible materials. This device is not intended for load bearing applications. Boundary NVISION BIOMEDICAL TECHNOLOGIES, INC.
17 90814008025377 AL-BUT-250 Buttress Plate 25mm long, 0 degree. The Boundary Anterior Lumbar Buttress Plate Buttress Plate 25mm long, 0 degree. The Boundary Anterior Lumbar Buttress Plate is intended to stabilize the allograft or autograft at one level (L1-S1) as an aid to spinal fusion and to provide temporary stabilization and augment development of a solid spinal fusion. It may be used alone or with other anterior, anterolateral, or posterior spinal systems made of compatible materials. This device is not intended for load bearing applications. Boundary NVISION BIOMEDICAL TECHNOLOGIES, INC.
18 90814008025360 AL-BUT-258 Buttress Plate 25mm long, 8 degree. The Boundary Anterior Lumbar Buttress Plate Buttress Plate 25mm long, 8 degree. The Boundary Anterior Lumbar Buttress Plate is intended to stabilize the allograft or autograft at one level (L1-S1) as an aid to spinal fusion and to provide temporary stabilization and augment development of a solid spinal fusion. It may be used alone or with other anterior, anterolateral, or posterior spinal systems made of compatible materials. This device is not intended for load bearing applications. Boundary NVISION BIOMEDICAL TECHNOLOGIES, INC.
19 90814008025353 AL-BUT-200 Buttress Plate 20mm long, 0 degree. The Boundary Anterior Lumbar Buttress Plate Buttress Plate 20mm long, 0 degree. The Boundary Anterior Lumbar Buttress Plate is intended to stabilize the allograft or autograft at one level (L1-S1) as an aid to spinal fusion and to provide temporary stabilization and augment development of a solid spinal fusion. It may be used alone or with other anterior, anterolateral, or posterior spinal systems made of compatible materials. This device is not intended for load bearing applications. Boundary NVISION BIOMEDICAL TECHNOLOGIES, INC.
20 90814008025346 AL-BUT-208 Buttress Plate 20mm long, 8 degree. The Boundary Anterior Lumbar Buttress Plate Buttress Plate 20mm long, 8 degree. The Boundary Anterior Lumbar Buttress Plate is intended to stabilize the allograft or autograft at one level (L1-S1) as an aid to spinal fusion and to provide temporary stabilization and augment development of a solid spinal fusion. It may be used alone or with other anterior, anterolateral, or posterior spinal systems made of compatible materials. This device is not intended for load bearing applications. Boundary NVISION BIOMEDICAL TECHNOLOGIES, INC.
21 90814008025339 AL-BUT-150 Buttress Plate 15mm long, 0 degree. The Boundary Anterior Lumbar Buttress Plate Buttress Plate 15mm long, 0 degree. The Boundary Anterior Lumbar Buttress Plate is intended to stabilize the allograft or autograft at one level (L1-S1) as an aid to spinal fusion and to provide temporary stabilization and augment development of a solid spinal fusion. It may be used alone or with other anterior, anterolateral, or posterior spinal systems made of compatible materials. This device is not intended for load bearing applications. Boundary NVISION BIOMEDICAL TECHNOLOGIES, INC.
22 90814008025322 AL-BUT-158 Buttress Plate 15mm long, 8 degree. The Boundary Anterior Lumbar Buttress Plate Buttress Plate 15mm long, 8 degree. The Boundary Anterior Lumbar Buttress Plate is intended to stabilize the allograft or autograft at one level (L1-S1) as an aid to spinal fusion and to provide temporary stabilization and augment development of a solid spinal fusion. It may be used alone or with other anterior, anterolateral, or posterior spinal systems made of compatible materials. This device is not intended for load bearing applications. Boundary NVISION BIOMEDICAL TECHNOLOGIES, INC.
23 90814008023847 ACP-425-20V Anterior Cervical Plating System, 4.25mm dia. 20mm long variable screw. The Tan Anterior Cervical Plating System, 4.25mm dia. 20mm long variable screw. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. Itis to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis tangis NVISION BIOMEDICAL TECHNOLOGIES, INC.
24 90814008023830 ACP-475-20V Anterior Cervical Plating System, 4.75mm dia. 20mm long variable screw tangis NVISION BIOMEDICAL TECHNOLOGIES, INC.
25 90814008023823 ACP-475-18V Anterior Cervical Plating System, 4.75mm dia. 18mm long variable screw tangis NVISION BIOMEDICAL TECHNOLOGIES, INC.
26 90814008023816 ACP-475-16V Anterior Cervical Plating System, 4.75mm dia. 16mm long variable screw tangis NVISION BIOMEDICAL TECHNOLOGIES, INC.
27 90814008023809 ACP-475-14V ACP-475-14V Anterior Cervical Plating System, 4.75mm dia. 14mm long variable screw. The Tan Anterior Cervical Plating System, 4.75mm dia. 14mm long variable screw. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis tangis NVISION BIOMEDICAL TECHNOLOGIES, INC.
28 90814008023793 ACP-475-12V Anterior Cervical Plating System, 4.75mm dia. 12mm long variable screw tangis NVISION BIOMEDICAL TECHNOLOGIES, INC.
29 90814008023786 ACP-475-10V Anterior Cervical Plating System, 4.75mm dia. 10mm long variable screw tangis NVISION BIOMEDICAL TECHNOLOGIES, INC.
30 90814008023779 ACP-425-18V Anterior Cervical Plating System, 4.25mm dia. 18mm long variable screw tangis NVISION BIOMEDICAL TECHNOLOGIES, INC.
31 90814008023762 ACP-425-16V Anterior Cervical Plating System, 4.25mm dia. 16mm long variable screw tangis NVISION BIOMEDICAL TECHNOLOGIES, INC.
32 90814008023755 ACP-425-14V Anterior Cervical Plating System, 4.25mm dia. 14mm long variable screw tangis NVISION BIOMEDICAL TECHNOLOGIES, INC.
33 90814008023748 ACP-425-12V ACP-425-12V Anterior Cervical Plating System, 4.25mm dia. 12mm long variable screw. The Tan Anterior Cervical Plating System, 4.25mm dia. 12mm long variable screw. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis tangis NVISION BIOMEDICAL TECHNOLOGIES, INC.
34 90814008023731 ACP-425-10V Anterior Cervical Plating System, 4.25mm dia. 10mm long variable scew tangis NVISION BIOMEDICAL TECHNOLOGIES, INC.
35 90814008023724 ACP-375-20V Anterior Cervical Plating System, 3.75mm dia. 20mm long variable screw tangis NVISION BIOMEDICAL TECHNOLOGIES, INC.
36 90814008023717 ACP-375-18V Anterior Cervical Plating System, 3.75mm dia. 18mm long variable screw tangis NVISION BIOMEDICAL TECHNOLOGIES, INC.
37 90814008023700 ACP-375-16V Anterior Cervical Plating System, 3.75mm dia. 16mm long variable screw tangis NVISION BIOMEDICAL TECHNOLOGIES, INC.
38 90814008023694 ACP-375-14V Anterior Cervical Plating System, 3.75mm dia. 14mm long variable screw tangis NVISION BIOMEDICAL TECHNOLOGIES, INC.
39 90814008023687 ACP-375-12V Anterior Cervical Plating System, 3.75mm dia. 12mm long variable screw tangis NVISION BIOMEDICAL TECHNOLOGIES, INC.
40 90814008023670 ACP-375-10V Anterior Cervical Plating System, 3.75mm dia. 10mm long variable screw tangis NVISION BIOMEDICAL TECHNOLOGIES, INC.
41 90814008023663 ACP-425-20F Anterior Cervical Plating System, 4.25mm dia. 20mm long fixed screw tangis NVISION BIOMEDICAL TECHNOLOGIES, INC.
42 90814008023656 ACP-425-18F Anterior Cervical Plating System, 4.25mm dia. 18mm long fixed screw tangis NVISION BIOMEDICAL TECHNOLOGIES, INC.
43 90814008023649 ACP-425-16F Anterior Cervical Plating System, 4.25mm dia. 16mm long fixed screw tangis NVISION BIOMEDICAL TECHNOLOGIES, INC.
44 90814008023632 ACP-425-14F Anterior Cervical Plating System, 4.25mm dia. 14mm long fixed screw tangis NVISION BIOMEDICAL TECHNOLOGIES, INC.
45 90814008023625 ACP-425-12F ACP-425-12F Anterior Cervical Plating System, 4.25mm dia. 12mm long fixed screw. The Tangis Anterior Cervical Plating System, 4.25mm dia. 12mm long fixed screw. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. Itis to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis tangis NVISION BIOMEDICAL TECHNOLOGIES, INC.
46 90814008023618 ACP-425-10F Anterior Cervical Plating System, 4.25mm dia. 10mm long fixed screw tangis NVISION BIOMEDICAL TECHNOLOGIES, INC.
47 90814008023601 ACP-375-20F Anterior Cervical Plating System, 3.75mm dia. 20mm long fixed screw tangis NVISION BIOMEDICAL TECHNOLOGIES, INC.
48 90814008023595 ACP-375-18F Anterior Cervical Plating System, 3.75mm dia. 18mm long fixed screw tangis NVISION BIOMEDICAL TECHNOLOGIES, INC.
49 90814008023588 ACP-375-16F Anterior Cervical Plating System, 3.75mm dia. 16mm long fixed screw tangis NVISION BIOMEDICAL TECHNOLOGIES, INC.
50 90814008023571 ACP-375-14F Anterior Cervical Plating System, 3.75mm dia. 14mm long fixed screw tangis NVISION BIOMEDICAL TECHNOLOGIES, INC.