Other products from "NOVOSCI CORP."
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 B066SHC060 SHC06 SHC06 A collection of sterile devices including tubing and typically clamps, filters, A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device. DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass 2 1/2" X 3/32" X 72" TUBE PACK
2 B066SFC060 SFC06 SFC06 A collection of sterile devices including tubing and typically clamps, filters, A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device. DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass 2 3/8" X 3/32" X 72" TUBE PACK
3 B066C445B1 C445B C445B A plastic device designed to join two or more tubes of a cardiopulmonary bypass A plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KOC Accessories, Blood Circuit, Hemodialysis CONNECTOR, Y 1/2" X 3/8" X 3/8" W/LUER
4 B066C430S0 C430S C430S A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KOC Accessories, Blood Circuit, Hemodialysis Reducing Conector Y 3/8 x 1/4 x1/4
5 B066C335S0 C335S C335S A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KOC Accessories, Blood Circuit, Hemodialysis Equal Y Connector 3/8 w luer
6 B066C320S0 C320S C320S A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KOC Accessories, Blood Circuit, Hemodialysis Equal Y Connector 1/4
7 B066C310S0 C310S C310S A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KOC Accessories, Blood Circuit, Hemodialysis Equal Y Connector 3/16"
8 B066C245B1 C245B C245B A plastic device designed to join two or more tubes of a cardiopulmonary bypass A plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KOC Accessories, Blood Circuit, Hemodialysis CONNECTOR, REDUCER 3/8" X 1/2" W/LUER
9 B066C145S0 C145S C145S A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KOC Accessories, Blood Circuit, Hemodialysis Straight Connector 1/2 x 1/2 w luer
10 B066C130S0 C130S C130S A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KOC Accessories, Blood Circuit, Hemodialysis Straight Connector 3/8"
11 B066C115S0 C115S C115S A plastic device designed to join two or more tubes of a cardiopulmonary bypass A plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KOC Accessories, Blood Circuit, Hemodialysis CONNECTOR, STRAIGHT 3/16" x 3/16" W/LUER
12 B0664110060000 411006-000 411006-000 A sterile device designed to facilitate/regulate the delivery of cardioplegic so A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device. DTR Heat-Exchanger, Cardiopulmonary Bypass Cardioplegia Administration Set
13 B0664110050000 411005-000 411005-000 A sterile device designed to facilitate/regulate the delivery of cardioplegic so A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device. DTR Heat-Exchanger, Cardiopulmonary Bypass Life Gift Cardiopelgia Administration Set
14 B066342333NS1 342333NS 342333NS A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KRI Accessory Equipment, Cardiopulmonary Bypass CONN, Y 3/8" X 3/8" X 3/8 W/LUER
15 B066342222NS1 342222NS 342222NS A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KRI Accessory Equipment, Cardiopulmonary Bypass CONN, Y 1/4" X 1/4" X 1/4" W/LUER
16 B0663422220000 342222-000 342222-000 A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KRI Accessory Equipment, Cardiopulmonary Bypass CONN, Y 1/4" X 1/4" X 1/4" W/LUER
17 B066341344NS1 341344NS 341344NS A plastic device designed to join two or more tubes of a cardiopulmonary bypass A plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KRI Accessory Equipment, Cardiopulmonary Bypass CONNECTOR, Y 3/8" x 1/2" x 1/2" W/O LUER
18 B0663413440000 341344-000 341344-000 A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KRI Accessory Equipment, Cardiopulmonary Bypass CONN, Y 3/8" X 1/2" X 1/2" W/O LUER
19 B066341232NS1 341232NS 341232NS A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KRI Accessory Equipment, Cardiopulmonary Bypass CONN, Y 1/4" X 3/8" X 1/4" W/O LUER
20 B0663412320000 341232-000 341232-000 A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KRI Accessory Equipment, Cardiopulmonary Bypass CONN, Y 1/4" X 3/8" X 1/4" W/O LUER
21 B066331033NS1 331033NS 331033NS A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KRI Accessory Equipment, Cardiopulmonary Bypass CONN, 3/8" X 3/8" W/O PART LINE
22 B0663310330000 331033-000 331033-000 A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KRI Accessory Equipment, Cardiopulmonary Bypass CONN, 3/8" X 3/8" W/O PART LINE
23 B066301009NS1 301009NS 301009NS A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. DTL Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass CONN, 1/4" PERFUSION ADAPTER
24 B066321222NS1 321222NS 321222NS A sterile device designed to facilitate/regulate the delivery of cardioplegic so A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device. DTL Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass CONN, 1/4" X 1/4" X 1/4" CLEAR PAY
25 B0663110340000 311034-000 311034-000 A small, sterile device with a locking/holding mechanism designed to secure most A small, sterile device with a locking/holding mechanism designed to secure most any kind of tubing or tubing-like device (e.g., cables, cords) to a patient or to a surgical drape during a clinical intervention. It is typically designed as: 1) an adhesive pad (plaster), strip, or bandage intended to attach to the patient's skin or drape with the exposed side (top side) having an integrated fixation mechanism (e.g., Velcro hook/loop closure); or 2) a mechanical closure or gripping system intended to hold the tubing or tubing hub in place. This device is not designed to hold a specific type or brand of tubing. This is a single-use device. DTL Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass PEDIATRIC TUBING ORGANIZER - STERILE
26 B0663011240000 301124-000 301124-000 A sterile, semi-rigid tube used in open heart surgery to facilitate the transfer A sterile, semi-rigid tube used in open heart surgery to facilitate the transfer of priming fluids during the priming of the extracorporeal circuit of a cardiopulmonary bypass system. It is a noninvasive product in the form of a tube or tubing used to channel the fluids (i.e., primer/blood) to facilitate priming of the extracorporeal circuit and connection of the cardiopulmonary bypass system (heart/lung machine) to the patient. It is typically a moulded plastic tube with hard plastic spike at the distal end that connects to the bag or container of primer solution, a connector at the proximal end, and a central pinch clamp. This is a single-use device. DTL Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass QUICKIE PRIME - 24" W/CLAMP
27 B066301094NS1 301094NS 301094NS 1/2" TUBING TO FIT OVER THE CORONARY PERFUSION OULTET PORT OF AN OXYGENATOR, TO 1/2" TUBING TO FIT OVER THE CORONARY PERFUSION OULTET PORT OF AN OXYGENATOR, TO SECURELY SEAL OFF THE PORT, THUS REDUCING THE POSSIBILITY OF THE PORT BEING INADVERTENTLY OPENED DURING THE HEMOPERFUSION PROCEDURE. DTL Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass 1/2" CORONARY PERFUSION PLUG
28 B0663010940000 301094-000 301094-000 1/2 TUBING TO FIT OVER THE CORONARY PERFUSION OUTLET PORT OF AN OXYGENATOR, TO 1/2 TUBING TO FIT OVER THE CORONARY PERFUSION OUTLET PORT OF AN OXYGENATOR, TO SECURELY SEAL OFF THE PORT, THUS REDUCING THE POSSIBLITY OF THE PORT BEING INADVERTENTLY OPENED DUTING THE HEMOPERFUSION PROCEEDURE. DTL Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass 1/2" CORONARY PERFUSION PLUG
29 B0663010220000 301022-000 301022-000 A sterile device designed to facilitate/regulate the delivery of cardioplegic so A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device. DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass 24" 1/8 x 1/32 Perfusion Adaptor Set w/Clear 1/4" PAC Male Luer
30 B0663010120000 301012-000 301012-000 A sterile, semi-rigid tube used in open heart surgery to facilitate the transfer A sterile, semi-rigid tube used in open heart surgery to facilitate the transfer of priming fluids during the priming of the extracorporeal circuit of a cardiopulmonary bypass system. It is a noninvasive product in the form of a tube or tubing used to channel the fluids (i.e., primer/blood) to facilitate priming of the extracorporeal circuit and connection of the cardiopulmonary bypass system (heart/lung machine) to the patient. It is typically a moulded plastic tube with hard plastic spike at the distal end that connects to the bag or container of primer solution, a connector at the proximal end, and a central pinch clamp. This is a single-use device. DTL Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass QUICKIE PRIME - 1/4" X 3/32"
31 B0663010090000 301009-000 301009-000 A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. DTL Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass CONN, 1/4" PERFUSION ADAPTER
32 B0663010010000 301001-000 301001-000 A sterile, porous device used in the arterial line of an extracorporeal circuit, A sterile, porous device used in the arterial line of an extracorporeal circuit, during a cardiopulmonary bypass procedure, to trap and remove potentially harmful gaseous emboli, aggregated blood constituents, and particles greater than a specified size (e.g., 40 microns) to prevent them from flowing into the bloodstream and obstructing extracorporeal circulation. It is commonly referred to as a bubble trap and will typically be used for a specified length of time (e.g., 6 hours). This is a single-use device. KRI Accessory Equipment, Cardiopulmonary Bypass FILTER, GAS/OXYGEN
33 B0662013010000 201301-000 201301-000 A hand-held device designed to regulate and direct a stream of pressurized fluid A hand-held device designed to regulate and direct a stream of pressurized fluid (e.g., sterile water or saline) and as an alternative provide aspiration (suction), to a surgical site, for the purpose of irrigating and clearing debris from the field of intervention. It is fitted with a long syringe-like nozzle that is activated by the user, typically through a push-type control(s). This device is typically a component of a surgical irrigation/aspiration system used for ENT or neurological surgery. This is a single-use device. DTS Sucker, Cardiotomy Return, Cardiopulmonary Bypass Tonsil Tip Sucker
34 B0662010110000 201011-000 201011-000 A general-purpose valve that is used to regulate the direction of a liquid or a A general-purpose valve that is used to regulate the direction of a liquid or a gas flow. It is typically constructed of a durable material, e.g., plastic and/or metal, and may be used for a variety of general-purpose uses. For stopcocks used in intravenous (IV) lines for injection or removal of fluids see the appropriate GMDN code. This is a single-use device. DTZ Oxygenator, Cardiopulmonary Bypass STOPCOCK, TMP 3-WAY W/LUER LOCK
35 B066201010NS1 201010NS 201010NS A sharp bevel-edged, hollow tubular metal instrument designed to remove fluid fr A sharp bevel-edged, hollow tubular metal instrument designed to remove fluid from a body cavity or to obtain a biopsy specimen from a patient through aspiration; it is not dedicated to a particular part of the anatomy. The device is typically longer than a hypodermic needle and usually has a wider hub. It is not intended for administration of pharmaceuticals. This is a single-use device. DWS Instruments, Surgical, Cardiovascular MODIFIED AIR ASPIRATOR NEEDLE W/GREEN CAP
36 B066201035NS1 201035NS 201035NS An assembly of devices designed to evacuate fluid, tissue, gas, or other foreign An assembly of devices designed to evacuate fluid, tissue, gas, or other foreign materials from a body cavity or lumen by means of suction. It generally consists of a suction pump powered by compressed air or oxygen from a hospital's central gas system, tubing, plastic/glass collection container(s), a vacuum gauge, a regulator, an overflow trap, a moisture filter, and possibly a microbial filter. The pressurized gas enables the pump to create a vacuum in the suction tubing, which is inserted into the body for the removal of materials into the collection container. This system can be used in a wide variety of hospital or other healthcare settings. DTS Sucker, Cardiotomy Return, Cardiopulmonary Bypass ADULT GROOVED - TIP SUCKER
37 B0662010150000 201015-000 201015-000 A sterile, sharp bevel-edged, hollow tubular metal instrument designed to remove A sterile, sharp bevel-edged, hollow tubular metal instrument designed to remove fluid from a body cavity or to obtain a biopsy specimen from a patient through aspiration; it is not dedicated to a particular part of the anatomy. The device is typically longer than a hypodermic needle and usually has a wider hub. This is a single-use device. DWS Instruments, Surgical, Cardiovascular 18ga Pediatric Air Aspirator Needle w/Pink Cap
38 B066VAVRSCP0 VAVRSCP VAVRSCP A collection of sterile devices including tubing and typically clamps, filters, A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device. DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass 2 STANDARD VAVR CONVERSION PAC
39 B066SFC120 SFC12 SFC12 A collection of sterile devices including tubing and typically clamps, filters, A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device. DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass 2 3/8" X 3/32" X 144" TUBE PACK
40 B066SFC080 SFC08 SFC08 A collection of sterile devices including tubing and typically clamps, filters, A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device. DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass 3/8" X 3/32" X 96" TUBE PACK
41 B066SFB100 SFB10 SFB10 A collection of sterile devices including tubing and typically clamps, filters, A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device. DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass 2 3/8" X 1/16" X 120" TUBE PACK
42 B066SDC040 SDC04 SDC04 A collection of sterile devices including tubing and typically clamps, filters, A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device. DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass 2 1/4" X 3/32" X 48" TUBE PACK
43 B066SDB060 SDB06 SDB06 A collection of sterile devices including tubing and typically clamps, filters, A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device. DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass 1/4" X 1/16" X 72" TUBE PACK
44 B066SDB020 SDB02 SDB02 A collection of sterile devices including tubing and typically clamps, filters, A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device. DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass 2 1/4" X 1/16" X 24" TUBE PACK
45 B066SCB080 SCB08 SCB08 A collection of sterile devices including tubing and typically clamps, filters, A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device. DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass 2 3/16" X 1/16" X 96" TUBE PACK
46 B066RHC020 RHC02 RHC02 A collection of sterile devices including tubing and typically clamps, filters, A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device. DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass 2 1/2" X 3/32" BULK TUBING - 100 FEET
47 B066C490B1 C490B C490B A plastic device designed to join two or more tubes of a cardiopulmonary bypass A plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KOC Accessories, Blood Circuit, Hemodialysis CONNECTOR, Y 1/2" X 1/2" X 1/4"
48 B066C445S0 C445S C445S A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KOC Accessories, Blood Circuit, Hemodialysis Reducing Connector Y 1/2 x 3/8 x 3/8 w luer
49 B066C340S0 C340S C340S A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KOC Accessories, Blood Circuit, Hemodialysis Equal Y Connector 1/2
50 B066C240S0 C240S C240S A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KOC Accessories, Blood Circuit, Hemodialysis Reducer Straight Connector 3/8 x 1/2
Other products with the same Product Code "DWF"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 00008544382026 TS3 Sentara Tubing Set Global Blood Resources GLOBAL BLOOD RESOURCES LLC
2 B270CVCP040080 CV.CP04008 CV.CP04008 Ostial Perfusion Cannula Ostial Sprit Cannulae SPYDER MEDICAL
3 B270CVCP040070 CV.CP04007 CV.CP04007 Ostial Perfusion Cannula Ostial Sprit Cannulae SPYDER MEDICAL
4 B270CVCP040060 CV.CP04006 CV.CP4006 Ostial Perfusion Cannula Ostial Sprit Cannulae SPYDER MEDICAL
5 B270CVCP040050 CV.CP04005 CV.CP04005 Ostial Perfusion Cannula Ostial Sprit Cannulae SPYDER MEDICAL
6 B270CVCP040040 CV.CP04004 CV.CP04004 Ostial Perfusion Cannula Ostial Sprit Cannulae SPYDER MEDICAL
7 B270CVCP030080 CV.CP03008 CV.CP03008 Ostial Perfusion Cannula Ostial Sprit Cannulae SPYDER MEDICAL
8 B270CVCP030070 CV.CP03007 CV.CP03007 Ostial Perfusion Cannula Ostial Sprit Cannulae SPYDER MEDICAL
9 B270CVCP030060 CV.CP03006 CV.CP03006 Ostial Perfusion Cannula Ostial Sprit Cannula SPYDER MEDICAL
10 B270CVCP030050 CV.CP03005 CV.CP03005 Ostial Sprit Cannula Ostial Sprit Cannulae SPYDER MEDICAL
11 B270CVCP030040 CV.CP03004 CV.CP03004 Ostial Perfusion Cannulae Ostial Sprit Cannulae SPYDER MEDICAL
12 B270CVCP020080 CV.CP02008 CV.CP02008 Ostial Perfusion Cannula Ostial Sprit Cannulae SPYDER MEDICAL
13 B270CVCP020070 CV.CP02007 CV.CP02007 Ostial Perfusion Cannula Ostial Sprit Cannulae SPYDER MEDICAL
14 B270CVCP020060 CV.CP02005 CV.CP02005 Ostial Perfusion Cannula Ostial Sprit Cannulae SPYDER MEDICAL
15 B270CVCP020050 CV.CP02005 CV.CP02005 Ostial Perfusion Cannula Ostial Sprit Cannulae SPYDER MEDICAL
16 B270CVCP020040 CV.CP02004 CV.CP02004 Ostial Perfusion Cannula Ostial Sprit Cannulae SPYDER MEDICAL
17 B270CVCP010080 CV.CP01008 CV.CP01008 Ostial Perfusion Cannula Ostial Sprit Cannulae SPYDER MEDICAL
18 B270CVCP010070 CV.CP01007 CV.CP01007 Ostial Perfusion Cannula Ostial Sprit Cannulae SPYDER MEDICAL
19 B270CVCP010060 CV.CP01006 CV.CP01006 Ostial Perfusion Cannula Ostial Sprit Cannulae SPYDER MEDICAL
20 B270CVCP010050 CV.CP01005 CV.CP01005 Ostial Perfusion Cannula Ostial Sprit Cannulae SPYDER MEDICAL
21 B270CVCP010040 CV.CP01004 CV.CP01004 Ostial Perfusion Cannulae Ostial Sprit Cannulae SPYDER MEDICAL
22 B1521580T088MM900 1580-T-08-8MM-90 1580-T-08-8MM-90 Perfusion Cannula. Tube Handle 9.5 inches long. Style # 8 Fixed Tip - 8 MM Tip Perfusion Cannula. Tube Handle 9.5 inches long. Style # 8 Fixed Tip - 8 MM Tip Diameter. 90 Degree Bend.Also available in: Large, Flag, & Small, Handle Styles PEMCO INC PEMCO INC
23 B1521580T088MM1200 1580-T-08-8MM-120 1580-T-08-8MM-120 Perfusion Cannula. Tube Handle 9.5 inches long. Style # 8 Fixed Tip - 8 MM Tip Perfusion Cannula. Tube Handle 9.5 inches long. Style # 8 Fixed Tip - 8 MM Tip Diameter. 120 Degree Bend.Also available in: Large, Flag, & Small, Handle Styles PEMCO INC PEMCO INC
24 B1521580T087MM900 1580-T-08-7MM-90 1580-T-08-7MM-90 Perfusion Cannula. Tube Handle 9.5 inches long. Style # 8 Fixed Tip - 7 MM Tip Perfusion Cannula. Tube Handle 9.5 inches long. Style # 8 Fixed Tip - 7 MM Tip Diameter. 90 Degree Bend.Also available in: Large, Flag, & Small, Handle Styles PEMCO INC PEMCO INC
25 B1521580T087MM1200 1580-T-08-7MM-120 1580-T-08-7MM-120 Perfusion Cannula. Tube Handle 9.5 inches long. Style # 8 Fixed Tip - 7 MM Tip Perfusion Cannula. Tube Handle 9.5 inches long. Style # 8 Fixed Tip - 7 MM Tip Diameter. 120 Degree Bend.Also available in: Large, Flag, & Small, Handle Styles PEMCO INC PEMCO INC
26 B1521580T086MM900 1580-T-08-6MM-90 1580-T-08-6MM-90 Perfusion Cannula. Tube Handle 9.5 inches long. Style # 8 Fixed Tip - 6 MM Tip Perfusion Cannula. Tube Handle 9.5 inches long. Style # 8 Fixed Tip - 6 MM Tip Diameter. 90 Degree Bend.Also available in: Large, Flag, & Small, Handle Styles PEMCO INC PEMCO INC
27 B1521580T086MM1200 1580-T-08-6MM-120 1580-T-08-6MM-120 Perfusion Cannula. Tube Handle 9.5 inches long. Style # 8 Fixed Tip - 6 MM Tip Perfusion Cannula. Tube Handle 9.5 inches long. Style # 8 Fixed Tip - 6 MM Tip Diameter. 120 Degree Bend.Also available in: Large, Flag, & Small, Handle Styles PEMCO INC PEMCO INC
28 B1521580T085MM900 1580-T-08-5MM-90 1580-T-08-5MM-90 Perfusion Cannula. Tube Handle 9.5 inches long. Style # 8 Fixed Tip - 5 MM Tip Perfusion Cannula. Tube Handle 9.5 inches long. Style # 8 Fixed Tip - 5 MM Tip Diameter. 90 Degree Bend.Also available in: Large, Flag, & Small, Handle Styles PEMCO INC PEMCO INC
29 B1521580T085MM1200 1580-T-08-5MM-120 1580-T-08-5MM-120 Perfusion Cannula. Tube Handle 9.5 inches long. Style # 8 Fixed Tip - 5 MM Tip Perfusion Cannula. Tube Handle 9.5 inches long. Style # 8 Fixed Tip - 5 MM Tip Diameter. 120 Degree Bend.Also available in: Large, Flag, & Small, Handle Styles PEMCO INC PEMCO INC
30 B1521580T084MM900 1580-T-08-4MM-90 1580-T-08-4MM-90 Perfusion Cannula. Tube Handle 9.5 inches long. Style # 8 Fixed Tip - 4 MM Tip Perfusion Cannula. Tube Handle 9.5 inches long. Style # 8 Fixed Tip - 4 MM Tip Diameter. 90 Degree Bend.Also available in: Large, Flag, & Small, Handle Styles PEMCO INC PEMCO INC
31 B1521580T084MM1200 1580-T-08-4MM-120 1580-T-08-4MM-120 Perfusion Cannula. Tube Handle 9.5 inches long. Style # 8 Fixed Tip - 4 MM Tip Perfusion Cannula. Tube Handle 9.5 inches long. Style # 8 Fixed Tip - 4 MM Tip Diameter. 120 Degree Bend.Also available in: Large, Flag, & Small, Handle Styles PEMCO INC PEMCO INC
32 B1521580T083MM900 1580-T-08-3MM-90 1580-T-08-3MM-90 Perfusion Cannula. Tube Handle 9.5 inches long. Style # 8 Fixed Tip - 3 MM Tip Perfusion Cannula. Tube Handle 9.5 inches long. Style # 8 Fixed Tip - 3 MM Tip Diameter. 90 Degree Bend.Also available in: Large, Flag, & Small, Handle Styles PEMCO INC PEMCO INC
33 B1521580T083MM1200 1580-T-08-3MM-120 1580-T-08-3MM-120 Perfusion Cannula. Tube Handle 9.5 inches long. Style # 8 Fixed Tip - 3 MM Tip Perfusion Cannula. Tube Handle 9.5 inches long. Style # 8 Fixed Tip - 3 MM Tip Diameter. 120 Degree Bend.Also available in: Large, Flag, & Small, Handle Styles PEMCO INC PEMCO INC
34 B1521580T082MM900 1580-T-08-2MM-90 1580-T-08-2MM-90 Perfusion Cannula. Tube Handle 9.5 inches long. Style # 8 Fixed Tip - 2 MM Tip Perfusion Cannula. Tube Handle 9.5 inches long. Style # 8 Fixed Tip - 2 MM Tip Diameter. 90 Degree Bend.Also available in: Large, Flag, & Small, Handle Styles PEMCO INC PEMCO INC
35 B1521580T082MM1200 1580-T-08-2MM-120 1580-T-08-2MM-120 Perfusion Cannula. Tube Handle 9.5 inches long. Style # 8 Fixed Tip - 2 MM Tip Perfusion Cannula. Tube Handle 9.5 inches long. Style # 8 Fixed Tip - 2 MM Tip Diameter. 120 Degree Bend.Also available in: Large, Flag, & Small, Handle Styles PEMCO INC PEMCO INC
36 B1521580P105MM650 1580-P-10-5MM-65 1580-P-10-5MM-65 Perfusion Cannula. Small Handle 7.5 inches long. Style # 10 Fixed Tip with sid Perfusion Cannula. Small Handle 7.5 inches long. Style # 10 Fixed Tip with side holes - 5 MM Tip Diameter. 65 Degree Bend.Also available in: Large, Flag, & Tube Handle Styles PEMCO INC PEMCO INC
37 B1521580P104MM650 1580-P-10-4MM-65 1580-P-10-4MM-65 Perfusion Cannula. Small Handle 7.5 inches long. Style # 10 Fixed Tip with sid Perfusion Cannula. Small Handle 7.5 inches long. Style # 10 Fixed Tip with side holes - 4 MM Tip Diameter. 65 Degree Bend.Also available in: Large, Flag, & Tube Handle Styles PEMCO INC PEMCO INC
38 B1521580P103MM650 1580-P-10-3MM-65 1580-P-10-3MM-65 Perfusion Cannula. Small Handle 7.5 inches long. Style # 10 Fixed Tip with sid Perfusion Cannula. Small Handle 7.5 inches long. Style # 10 Fixed Tip with side holes - 3 MM Tip Diameter. 65 Degree Bend.Also available in: Large, Flag, & Tube Handle Styles PEMCO INC PEMCO INC
39 B1521580P102MM650 1580-P-10-2MM-65 1580-P-10-2MM-65 Perfusion Cannula. Small Handle 7.5 inches long. Style # 10 Fixed Tip with side Perfusion Cannula. Small Handle 7.5 inches long. Style # 10 Fixed Tip with side holes - 2 MM Tip Diameter. 65 Degree Bend.Also available in: Large, Flag, & Tube Handle Styles PEMCO INC PEMCO INC
40 B1521580P101MM1450 1580-P-10-1MM-145 1580-P-10-1MM-145 Perfusion Cannula. Small Handle 7.5 inches long. Style # 10 Fixed Tip with sid Perfusion Cannula. Small Handle 7.5 inches long. Style # 10 Fixed Tip with side holes - 1 MM Tip Diameter. 145 Degree Bend.Also available in: Large, Flag, & Tube Handle Styles PEMCO INC PEMCO INC
41 B1521580P095MM900 1580-P-09-5MM-90 1580-P-09-5MM-90 Perfusion Cannula. Small Handle 6.5 inches long. Style # 9 Fixed Tip - 5 MM Tip Perfusion Cannula. Small Handle 6.5 inches long. Style # 9 Fixed Tip - 5 MM Tip Diameter. 90 Degree Bend.Also available in: Large, Flag, & Tube Handle Styles PEMCO INC PEMCO INC
42 B1521580P094MM900 1580-P-09-4MM-90 1580-P-09-4MM-90 Perfusion Cannula. Small Handle 6.5 inches long. Style #9 Fixed Tip - 4 MM Tip Perfusion Cannula. Small Handle 6.5 inches long. Style #9 Fixed Tip - 4 MM Tip Diameter. 90 Degree Bend.Also available in: Large, Flag, & Tube Handle Styles PEMCO INC PEMCO INC
43 B1521580P093MM900 1580-P-09-3MM-90 1580-P-09-3MM-90 Perfusion Cannula. Small Handle 6.5 inches long. Style # 9 Fixed Tip - 3 MM Ti Perfusion Cannula. Small Handle 6.5 inches long. Style # 9 Fixed Tip - 3 MM Tip Diameter. 90 Degree Bend.Also available in: Large, Flag, & Tube Handle Styles PEMCO INC PEMCO INC
44 B1521580P092MM900 1580-P-09-2MM-90 1580-P-09-2MM-90 Perfusion Cannula. Small Handle 6.5 inches long. Style # 9 Fixed Tip - 2 MM Ti Perfusion Cannula. Small Handle 6.5 inches long. Style # 9 Fixed Tip - 2 MM Tip Diameter. 90 Degree Bend.Also available in: Large, Flag, & Tube Handle Styles PEMCO INC PEMCO INC
45 B1521580P075MM750 1580-P-07-5MM-75 1580-P-07-5MM-75 Perfusion Cannula. Small Handle 6.5 inches long. Style # 7 Swivel Tip - 5 MM T Perfusion Cannula. Small Handle 6.5 inches long. Style # 7 Swivel Tip - 5 MM Tip Diameter. 75 Degree Bend.Also available in: Large, Flag, & Tube Handle Styles PEMCO INC PEMCO INC
46 B1521580P074MM750 1580-P-07-4MM-75 1580-P-07-4MM-75 Perfusion Cannula. Small Handle 6.5 inches long. Style # 7 Swivel Tip - 4 MM T Perfusion Cannula. Small Handle 6.5 inches long. Style # 7 Swivel Tip - 4 MM Tip Diameter. 75 Degree Bend.Also available in: Large, Flag, & Tube Handle Styles PEMCO INC PEMCO INC
47 B1521580P073MM750 1580-P-07-3MM-75 1580-P-07-3MM-75 Perfusion Cannula. Small Handle 6.5 inches long. Style # 7 Swivel Tip - 3 MM T Perfusion Cannula. Small Handle 6.5 inches long. Style # 7 Swivel Tip - 3 MM Tip Diameter. 75 Degree Bend.Also available in: Large, Flag, & Tube Handle Styles PEMCO INC PEMCO INC
48 B1521580P072MM750 1580-P-07-2MM-75 1580-P-07-2MM-75 Perfusion Cannula. Small Handle 6.5 inches long. Style # 7 Swivel Tip - 2 MM T Perfusion Cannula. Small Handle 6.5 inches long. Style # 7 Swivel Tip - 2 MM Tip Diameter. 75 Degree Bend.Also available in: Large, Flag, & Tube Handle Styles PEMCO INC PEMCO INC
49 B1521580P065MM1200 1580-P-06-5MM-120 1580-P-06-5MM-120 Perfusion Cannula. Small Handle 6.5 inches long. Style # 6 Fixed Tip with side Perfusion Cannula. Small Handle 6.5 inches long. Style # 6 Fixed Tip with side holes - 5 MM Tip Diameter. 120 Degree Bend.Also available in: Large, Flag, & Tube Handle Styles PEMCO INC PEMCO INC
50 B1521580P064MM1200 1580-P-06-4MM-120 1580-P-06-4MM-120 Perfusion Cannula. Small Handle 6.5 inches long. Style # 6 Fixed Tip with side Perfusion Cannula. Small Handle 6.5 inches long. Style # 6 Fixed Tip with side holes - 4 MM Tip Diameter. 120 Degree Bend.Also available in: Large, Flag, & Tube Handle Styles PEMCO INC PEMCO INC