No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 B066SHC060 SHC06 SHC06 A collection of sterile devices including tubing and typically clamps, filters, A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device. DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass 2 1/2" X 3/32" X 72" TUBE PACK
2 B066SFC060 SFC06 SFC06 A collection of sterile devices including tubing and typically clamps, filters, A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device. DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass 2 3/8" X 3/32" X 72" TUBE PACK
3 B066C445B1 C445B C445B A plastic device designed to join two or more tubes of a cardiopulmonary bypass A plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KOC Accessories, Blood Circuit, Hemodialysis CONNECTOR, Y 1/2" X 3/8" X 3/8" W/LUER
4 B066C430S0 C430S C430S A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KOC Accessories, Blood Circuit, Hemodialysis Reducing Conector Y 3/8 x 1/4 x1/4
5 B066C335S0 C335S C335S A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KOC Accessories, Blood Circuit, Hemodialysis Equal Y Connector 3/8 w luer
6 B066C320S0 C320S C320S A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KOC Accessories, Blood Circuit, Hemodialysis Equal Y Connector 1/4
7 B066C310S0 C310S C310S A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KOC Accessories, Blood Circuit, Hemodialysis Equal Y Connector 3/16"
8 B066C245B1 C245B C245B A plastic device designed to join two or more tubes of a cardiopulmonary bypass A plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KOC Accessories, Blood Circuit, Hemodialysis CONNECTOR, REDUCER 3/8" X 1/2" W/LUER
9 B066C145S0 C145S C145S A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KOC Accessories, Blood Circuit, Hemodialysis Straight Connector 1/2 x 1/2 w luer
10 B066C130S0 C130S C130S A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KOC Accessories, Blood Circuit, Hemodialysis Straight Connector 3/8"
11 B066C115S0 C115S C115S A plastic device designed to join two or more tubes of a cardiopulmonary bypass A plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KOC Accessories, Blood Circuit, Hemodialysis CONNECTOR, STRAIGHT 3/16" x 3/16" W/LUER
12 B0664110060000 411006-000 411006-000 A sterile device designed to facilitate/regulate the delivery of cardioplegic so A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device. DTR Heat-Exchanger, Cardiopulmonary Bypass Cardioplegia Administration Set
13 B0664110050000 411005-000 411005-000 A sterile device designed to facilitate/regulate the delivery of cardioplegic so A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device. DTR Heat-Exchanger, Cardiopulmonary Bypass Life Gift Cardiopelgia Administration Set
14 B066342333NS1 342333NS 342333NS A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KRI Accessory Equipment, Cardiopulmonary Bypass CONN, Y 3/8" X 3/8" X 3/8 W/LUER
15 B066342222NS1 342222NS 342222NS A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KRI Accessory Equipment, Cardiopulmonary Bypass CONN, Y 1/4" X 1/4" X 1/4" W/LUER
16 B0663422220000 342222-000 342222-000 A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KRI Accessory Equipment, Cardiopulmonary Bypass CONN, Y 1/4" X 1/4" X 1/4" W/LUER
17 B066341344NS1 341344NS 341344NS A plastic device designed to join two or more tubes of a cardiopulmonary bypass A plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KRI Accessory Equipment, Cardiopulmonary Bypass CONNECTOR, Y 3/8" x 1/2" x 1/2" W/O LUER
18 B0663413440000 341344-000 341344-000 A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KRI Accessory Equipment, Cardiopulmonary Bypass CONN, Y 3/8" X 1/2" X 1/2" W/O LUER
19 B066341232NS1 341232NS 341232NS A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KRI Accessory Equipment, Cardiopulmonary Bypass CONN, Y 1/4" X 3/8" X 1/4" W/O LUER
20 B0663412320000 341232-000 341232-000 A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KRI Accessory Equipment, Cardiopulmonary Bypass CONN, Y 1/4" X 3/8" X 1/4" W/O LUER
21 B066331033NS1 331033NS 331033NS A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KRI Accessory Equipment, Cardiopulmonary Bypass CONN, 3/8" X 3/8" W/O PART LINE
22 B0663310330000 331033-000 331033-000 A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KRI Accessory Equipment, Cardiopulmonary Bypass CONN, 3/8" X 3/8" W/O PART LINE
23 B066301009NS1 301009NS 301009NS A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. DTL Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass CONN, 1/4" PERFUSION ADAPTER
24 B066321222NS1 321222NS 321222NS A sterile device designed to facilitate/regulate the delivery of cardioplegic so A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device. DTL Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass CONN, 1/4" X 1/4" X 1/4" CLEAR PAY
25 B0663110340000 311034-000 311034-000 A small, sterile device with a locking/holding mechanism designed to secure most A small, sterile device with a locking/holding mechanism designed to secure most any kind of tubing or tubing-like device (e.g., cables, cords) to a patient or to a surgical drape during a clinical intervention. It is typically designed as: 1) an adhesive pad (plaster), strip, or bandage intended to attach to the patient's skin or drape with the exposed side (top side) having an integrated fixation mechanism (e.g., Velcro hook/loop closure); or 2) a mechanical closure or gripping system intended to hold the tubing or tubing hub in place. This device is not designed to hold a specific type or brand of tubing. This is a single-use device. DTL Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass PEDIATRIC TUBING ORGANIZER - STERILE
26 B0663011240000 301124-000 301124-000 A sterile, semi-rigid tube used in open heart surgery to facilitate the transfer A sterile, semi-rigid tube used in open heart surgery to facilitate the transfer of priming fluids during the priming of the extracorporeal circuit of a cardiopulmonary bypass system. It is a noninvasive product in the form of a tube or tubing used to channel the fluids (i.e., primer/blood) to facilitate priming of the extracorporeal circuit and connection of the cardiopulmonary bypass system (heart/lung machine) to the patient. It is typically a moulded plastic tube with hard plastic spike at the distal end that connects to the bag or container of primer solution, a connector at the proximal end, and a central pinch clamp. This is a single-use device. DTL Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass QUICKIE PRIME - 24" W/CLAMP
27 B066301094NS1 301094NS 301094NS 1/2" TUBING TO FIT OVER THE CORONARY PERFUSION OULTET PORT OF AN OXYGENATOR, TO 1/2" TUBING TO FIT OVER THE CORONARY PERFUSION OULTET PORT OF AN OXYGENATOR, TO SECURELY SEAL OFF THE PORT, THUS REDUCING THE POSSIBILITY OF THE PORT BEING INADVERTENTLY OPENED DURING THE HEMOPERFUSION PROCEDURE. DTL Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass 1/2" CORONARY PERFUSION PLUG
28 B0663010940000 301094-000 301094-000 1/2 TUBING TO FIT OVER THE CORONARY PERFUSION OUTLET PORT OF AN OXYGENATOR, TO 1/2 TUBING TO FIT OVER THE CORONARY PERFUSION OUTLET PORT OF AN OXYGENATOR, TO SECURELY SEAL OFF THE PORT, THUS REDUCING THE POSSIBLITY OF THE PORT BEING INADVERTENTLY OPENED DUTING THE HEMOPERFUSION PROCEEDURE. DTL Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass 1/2" CORONARY PERFUSION PLUG
29 B0663010220000 301022-000 301022-000 A sterile device designed to facilitate/regulate the delivery of cardioplegic so A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device. DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass 24" 1/8 x 1/32 Perfusion Adaptor Set w/Clear 1/4" PAC Male Luer
30 B0663010120000 301012-000 301012-000 A sterile, semi-rigid tube used in open heart surgery to facilitate the transfer A sterile, semi-rigid tube used in open heart surgery to facilitate the transfer of priming fluids during the priming of the extracorporeal circuit of a cardiopulmonary bypass system. It is a noninvasive product in the form of a tube or tubing used to channel the fluids (i.e., primer/blood) to facilitate priming of the extracorporeal circuit and connection of the cardiopulmonary bypass system (heart/lung machine) to the patient. It is typically a moulded plastic tube with hard plastic spike at the distal end that connects to the bag or container of primer solution, a connector at the proximal end, and a central pinch clamp. This is a single-use device. DTL Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass QUICKIE PRIME - 1/4" X 3/32"
31 B0663010090000 301009-000 301009-000 A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. DTL Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass CONN, 1/4" PERFUSION ADAPTER
32 B0663010010000 301001-000 301001-000 A sterile, porous device used in the arterial line of an extracorporeal circuit, A sterile, porous device used in the arterial line of an extracorporeal circuit, during a cardiopulmonary bypass procedure, to trap and remove potentially harmful gaseous emboli, aggregated blood constituents, and particles greater than a specified size (e.g., 40 microns) to prevent them from flowing into the bloodstream and obstructing extracorporeal circulation. It is commonly referred to as a bubble trap and will typically be used for a specified length of time (e.g., 6 hours). This is a single-use device. KRI Accessory Equipment, Cardiopulmonary Bypass FILTER, GAS/OXYGEN
33 B0662013010000 201301-000 201301-000 A hand-held device designed to regulate and direct a stream of pressurized fluid A hand-held device designed to regulate and direct a stream of pressurized fluid (e.g., sterile water or saline) and as an alternative provide aspiration (suction), to a surgical site, for the purpose of irrigating and clearing debris from the field of intervention. It is fitted with a long syringe-like nozzle that is activated by the user, typically through a push-type control(s). This device is typically a component of a surgical irrigation/aspiration system used for ENT or neurological surgery. This is a single-use device. DTS Sucker, Cardiotomy Return, Cardiopulmonary Bypass Tonsil Tip Sucker
34 B0662010110000 201011-000 201011-000 A general-purpose valve that is used to regulate the direction of a liquid or a A general-purpose valve that is used to regulate the direction of a liquid or a gas flow. It is typically constructed of a durable material, e.g., plastic and/or metal, and may be used for a variety of general-purpose uses. For stopcocks used in intravenous (IV) lines for injection or removal of fluids see the appropriate GMDN code. This is a single-use device. DTZ Oxygenator, Cardiopulmonary Bypass STOPCOCK, TMP 3-WAY W/LUER LOCK
35 B066201010NS1 201010NS 201010NS A sharp bevel-edged, hollow tubular metal instrument designed to remove fluid fr A sharp bevel-edged, hollow tubular metal instrument designed to remove fluid from a body cavity or to obtain a biopsy specimen from a patient through aspiration; it is not dedicated to a particular part of the anatomy. The device is typically longer than a hypodermic needle and usually has a wider hub. It is not intended for administration of pharmaceuticals. This is a single-use device. DWS Instruments, Surgical, Cardiovascular MODIFIED AIR ASPIRATOR NEEDLE W/GREEN CAP
36 B066201035NS1 201035NS 201035NS An assembly of devices designed to evacuate fluid, tissue, gas, or other foreign An assembly of devices designed to evacuate fluid, tissue, gas, or other foreign materials from a body cavity or lumen by means of suction. It generally consists of a suction pump powered by compressed air or oxygen from a hospital's central gas system, tubing, plastic/glass collection container(s), a vacuum gauge, a regulator, an overflow trap, a moisture filter, and possibly a microbial filter. The pressurized gas enables the pump to create a vacuum in the suction tubing, which is inserted into the body for the removal of materials into the collection container. This system can be used in a wide variety of hospital or other healthcare settings. DTS Sucker, Cardiotomy Return, Cardiopulmonary Bypass ADULT GROOVED - TIP SUCKER
37 B0662010150000 201015-000 201015-000 A sterile, sharp bevel-edged, hollow tubular metal instrument designed to remove A sterile, sharp bevel-edged, hollow tubular metal instrument designed to remove fluid from a body cavity or to obtain a biopsy specimen from a patient through aspiration; it is not dedicated to a particular part of the anatomy. The device is typically longer than a hypodermic needle and usually has a wider hub. This is a single-use device. DWS Instruments, Surgical, Cardiovascular 18ga Pediatric Air Aspirator Needle w/Pink Cap
38 B066VAVRSCP0 VAVRSCP VAVRSCP A collection of sterile devices including tubing and typically clamps, filters, A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device. DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass 2 STANDARD VAVR CONVERSION PAC
39 B066SFC120 SFC12 SFC12 A collection of sterile devices including tubing and typically clamps, filters, A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device. DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass 2 3/8" X 3/32" X 144" TUBE PACK
40 B066SFC080 SFC08 SFC08 A collection of sterile devices including tubing and typically clamps, filters, A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device. DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass 3/8" X 3/32" X 96" TUBE PACK
41 B066SFB100 SFB10 SFB10 A collection of sterile devices including tubing and typically clamps, filters, A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device. DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass 2 3/8" X 1/16" X 120" TUBE PACK
42 B066SDC040 SDC04 SDC04 A collection of sterile devices including tubing and typically clamps, filters, A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device. DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass 2 1/4" X 3/32" X 48" TUBE PACK
43 B066SDB060 SDB06 SDB06 A collection of sterile devices including tubing and typically clamps, filters, A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device. DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass 1/4" X 1/16" X 72" TUBE PACK
44 B066SDB020 SDB02 SDB02 A collection of sterile devices including tubing and typically clamps, filters, A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device. DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass 2 1/4" X 1/16" X 24" TUBE PACK
45 B066SCB080 SCB08 SCB08 A collection of sterile devices including tubing and typically clamps, filters, A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device. DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass 2 3/16" X 1/16" X 96" TUBE PACK
46 B066RHC020 RHC02 RHC02 A collection of sterile devices including tubing and typically clamps, filters, A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device. DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass 2 1/2" X 3/32" BULK TUBING - 100 FEET
47 B066C490B1 C490B C490B A plastic device designed to join two or more tubes of a cardiopulmonary bypass A plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KOC Accessories, Blood Circuit, Hemodialysis CONNECTOR, Y 1/2" X 1/2" X 1/4"
48 B066C445S0 C445S C445S A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KOC Accessories, Blood Circuit, Hemodialysis Reducing Connector Y 1/2 x 3/8 x 3/8 w luer
49 B066C340S0 C340S C340S A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KOC Accessories, Blood Circuit, Hemodialysis Equal Y Connector 1/2
50 B066C240S0 C240S C240S A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KOC Accessories, Blood Circuit, Hemodialysis Reducer Straight Connector 3/8 x 1/2
Other products with the same Product Code "DTL"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 04543660023515 GLGMF-YOK0A This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with kit and one(1) sterile pouch with a GM-30 Inflation Device.The OKAY® II Y-Connector Set reduces blood loss during procedures through the use of a hemostatic valve not featured on conventional Y-connectors. Its large 3.33mm (10F) inner diameter facilitates a variety of PCI devices and techniques, and a new feature has been added that allows the one-touch style hemostatic valve to be locked in the open position. Includes Y-connector, torque device, and introducer. (YOK0A)The GM-30 30atm-25cc inflation device features standard length, 31 cm, high pressure tubing and 4 position stopcock for single or dual angioplasty balloon inflation and deflation. (GM-30NF)Indications for Use:1. The Y-connector is designed to work in conjunction with guiding catheters, etc. to reduce blood loss while assisting in manipulation of catheters, etc., injection of contrast solution from a side port, injection of medicine or saline solution, and measurement of blood pressure.2. The inflation device is recommended for use with balloon dilation catheters to create and monitor pressure in the balloon, and to deflate the balloon. GM-30 Accessory Kit INFRAREDX, INC.
2 04543660023508 GLGMN-YOK0A This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with kit and one(1) sterile pouch with a GM-30 Inflation Device.OKAY® II Y-Connector Set with Extension Tube reduces blood loss during procedures through the use of a hemostatic valve not featured on conventional Y connectors. Its large 3.33mm (10F) inner diameter facilitates a variety of PCI devices and techniques, and a new feature has been added that allows the one-touch style hemostatic valve to be locked in the open position. Includes Y-connector, torque device, and introducer. (YOK0A)The GM-30 30atm-25cc inflation device features standard length, 31 cm, high pressure tubing and 3 position stopcock for single angioplasty balloon inflation and deflation. (GM-30N)Indications for Use:1. The Y-connector is designed to work in conjunction with guiding catheters, etc. to reduce blood loss while assisting in manipulation of catheters, etc., injection of contrast solution from a side port, injection of medicine or saline solution, and measurement of blood pressure.2. The inflation device is recommended for use with balloon dilation catheters to create and monitor pressure in the balloon, and to deflate the balloon. GM-30 Accessory Kit INFRAREDX, INC.
3 04543660023492 GLGMF-YOK0E This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with kit and extension tube and one(1) sterile pouch with a GM-30 Inflation Device.OKAY® II Y-Connector Set with Extension Tube reduces blood loss during procedures through the use of a hemostatic valve not featured on conventional Y connectors. Its large 3.33mm (10F) inner diameter facilitates a variety of PCI devices and techniques, and a new feature has been added that allows the one-touch style hemostatic valve to be locked in the open position. Includes Y-connector, torque device, introducer, and extension tube. (YOK0E)The GM-30 30atm-25cc inflation device features standard length, 31 cm, high pressure tubing and 4 position stopcock for single or dual angioplasty balloon inflation and deflation. (GM-30NF)Indications for Use:1. The Y-connector is designed to work in conjunction with guiding catheters, etc. to reduce blood loss while assisting in manipulation of catheters, etc., injection of contrast solution from a side port, injection of medicine or saline solution, and measurement of blood pressure.2. The inflation device is recommended for use with balloon dilation catheters to create and monitor pressure in the balloon, and to deflate the balloon. GM-30 Accessory Kit INFRAREDX, INC.
4 04543660023485 GLGMN-YOK0E This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with kit and extension tube and one(1) sterile pouch with a GM-30 Inflation Device.OKAY® II Y-Connector Set with Extension Tube reduces blood loss during procedures through the use of a hemostatic valve not featured on conventional Y connectors. Its large 3.33mm (10F) inner diameter facilitates a variety of PCI devices and techniques, and a new feature has been added that allows the one-touch style hemostatic valve to be locked in the open position. Includes Y-connector, torque device, introducer, and extension tube. (YOK0E)The GM-30 30atm-25cc inflation device features standard length, 31 cm, high pressure tubing and 3 position stopcock for single angioplasty balloon inflation and deflation. (GM-30N)Indications for Use:1. The Y-connector is designed to work in conjunction with guiding catheters, etc. to reduce blood loss while assisting in manipulation of catheters, etc., injection of contrast solution from a side port, injection of medicine or saline solution, and measurement of blood pressure.2. The inflation device is recommended for use with balloon dilation catheters to create and monitor pressure in the balloon, and to deflate the balloon. GM-30 Accessory Kit INFRAREDX, INC.
5 04543660022358 YOK0E OKAY II reduces blood loss during procedures through the use of a hemostatic val OKAY II reduces blood loss during procedures through the use of a hemostatic valve not featured on conventional Y connectors. Its large 3.33mm (10F) inner diameter facilitates a variety of PCI devices and techniques, and a new feature has been added that allows the one-touch style hemostatic valve to be locked in the open position. Includes Y-connector, torque device, introducer, and extension tube.Indications for Use:1. This product is designed to work in conjunction with guiding catheters, etc. to reduce blood loss while assisting in manipulation of catheters, etc., injection of contrast solution from a side port, injection of medicine or saline solution, and measurement of blood pressure. OKAY® II Y-Connector Set with Extension Tube INFRAREDX, INC.
6 04543660022341 YOK0B OKAY II reduces blood loss during procedures through the use of a hemostatic val OKAY II reduces blood loss during procedures through the use of a hemostatic valve not featured on conventional Y connectors. Its large 3.33mm (10F) inner diameter facilitates a variety of PCI devices and techniques, and a new feature has been added that allows the one-touch style hemostatic valve to be locked in the open position. Includes Y-connector.Indications for Use:1. This product is designed to work in conjunction with guiding catheters, etc. to reduce blood loss while assisting in manipulation of catheters, etc., injection of contrast solution from a side port, injection of medicine or saline solution, and measurement of blood pressure. OKAY® II Y-Connector INFRAREDX, INC.
7 04543660022334 YOK0A OKAY II reduces blood loss during procedures through the use of a hemostatic val OKAY II reduces blood loss during procedures through the use of a hemostatic valve not featured on conventional Y connectors. Its large 3.33mm (10F) inner diameter facilitates a variety of PCI devices and techniques, and a new feature has been added that allows the one-touch style hemostatic valve to be locked in the open position. Includes Y-connector, torque device, and introducer.Indications for Use:1. This product is designed to work in conjunction with guiding catheters, etc. to reduce blood loss while assisting in manipulation of catheters, etc., injection of contrast solution from a side port, injection of medicine or saline solution, and measurement of blood pressure. OKAY® II Y-Connector Set INFRAREDX, INC.
8 04046964183669 456080 456080 DMA 1000 Dual Male Adapter Connector B. BRAUN MEDICAL INC.
9 04037691242743 Ven.Cath.,2-stage,reinf.,ell.,Light.tip 70100.5721 Venous Catheter, two-stage, SLIM, complete reinforcement, elliptic proximal body Venous Catheter, two-stage, SLIM, complete reinforcement, elliptic proximal body, Lighthouse tip, with connector NA MAQUET CARDIOPULMONARY AG
10 04037691242576 Ven.Cath.,2-stage,reinf.,Bullet tip 70100.5672 Venous Catheter, two-stage, complete reinforcement, Bullet tip, with connector NA MAQUET CARDIOPULMONARY AG
11 04037691123820 Ven.Cath.,2-stage,reinf.,ell.,Light.tip 70101.4232 Venous Catheter, two-stage, SLIM, complete reinforcement, elliptic proximal body Venous Catheter, two-stage, SLIM, complete reinforcement, elliptic proximal body, Lighthouse tip, with connector NA MAQUET CARDIOPULMONARY AG
12 04037691085111 Ven.Cath.,2-stage,reinf.,Bullet tip 70100.5713 Venous Catheter, two-stage, SLIM, complete reinforcement, Bullet tip, without connector NA MAQUET CARDIOPULMONARY AG
13 04037691085104 Ven.Cath.,2-stage,reinf.,Bullet tip 70100.5686 Venous Catheter, two-stage, complete reinforcement, Bullet tip, without connector NA MAQUET CARDIOPULMONARY AG
14 04037691085098 Ven.Cath.,2-stage,reinf.,Bullet tip 70100.5668 Venous Catheter, two-stage, complete reinforcement, Bullet tip, without connector NA MAQUET CARDIOPULMONARY AG
15 04037691085043 Ven.Cath.,2-stage,reinf.,Bullet tip 70100.5716 Venous Catheter, two-stage, SLIM, complete reinforcement, Bullet tip, with Lur l Venous Catheter, two-stage, SLIM, complete reinforcement, Bullet tip, with Lur lock connector NA MAQUET CARDIOPULMONARY AG
16 04037691085036 Ven.Cath.,2-stage,reinf.,Lighthouse tip 70100.5720 Venous Catheter, two-stage, SLIM, complete reinforcement, Lighthouse tip, with connector NA MAQUET CARDIOPULMONARY AG
17 04037691085005 Ven.Cath.,2-stage,reinf.,Bullet tip 70100.5714 Venous Catheter, two-stage, SLIM, complete reinforcement, Bullet tip, with connector NA MAQUET CARDIOPULMONARY AG
18 04037691084961 Ven.Cath.,2-stage,reinf.,Bullet tip 70100.5670 Venous Catheter, two-stage, complete reinforcement, Bullet tip, with connector NA MAQUET CARDIOPULMONARY AG
19 04037691064338 Ven.Cath.,2-stage,reinf.,Light.tip,bent 70101.3029 Venous Catheter, two-stage, SLIM, complete reinforcement, Lighthouse tip, pre-be Venous Catheter, two-stage, SLIM, complete reinforcement, Lighthouse tip, pre-bent 120°, without connector NA MAQUET CARDIOPULMONARY AG
20 03660812136532 876.20 00087620 Vycliccolor VYGON VYGON
21 03660812038409 876.20 876.20 Vyclic 3-way stopcock VYGON VYGON
22 03660812009386 879.00 879.00 4 way stopcock for exchange transfusion VYGON VYGON
23 03660812009232 873.04 00087304 Ramp of stopcocks Luer-lock with extension tube L.50cm - 4 one-way stopcocks VYGON VYGON
24 03660812009201 872.10 872.10 Lockable one-way stopcock VYGON VYGON
25 00886333208678 197248 197248 Contrast Injection Line 48" (122cm) M/F (PVC) 1000 PSI Contrast Injection Line ARGON MEDICAL DEVICES, INC.
26 00886333208661 196590 196590 3 Way Stopcock w/ Rotating Adapter(1050psi) Stopcock ARGON MEDICAL DEVICES, INC.
27 00886333207602 193403 193403 Manifold Kit #4 500 PSI Right/On/Open Body Manifold Kit #4 ARGON MEDICAL DEVICES, INC.
28 00886333207589 193382 193382 Contrast Line 96"(244cm) Female/Rotating Adapter Polyurethane, Braided 1200 PSI Contrast Line ARGON MEDICAL DEVICES, INC.
29 00886333207572 193381 193381 Contrast Line 96"(244cm) Male/Female Polyurethane, Braided 1200 PSI Contrast Line ARGON MEDICAL DEVICES, INC.
30 00886333207565 193378 193378 Contrast Line 72"(183cm) Female/Rotating Adapter Polyurethane, Braided 1200 PSI Contrast Line ARGON MEDICAL DEVICES, INC.
31 00886333207558 193377 193377 Contrast Line 72"(183cm) Male/Female Polyurethane, Braided 1200 PSI Contrast Line ARGON MEDICAL DEVICES, INC.
32 00886333207541 193376 193376 Contrast Line 60"(152cm) Male/Female Polyurethane, Braided 1200 PSI Contrast Line ARGON MEDICAL DEVICES, INC.
33 00886333207534 193375 193375 Contrast Line 60"(152cm) Female/Rotating Adapter Polyurethane, Braided 1200 PSI Contrast Line ARGON MEDICAL DEVICES, INC.
34 00886333207527 193373 193373 Contrast Line 72"(183cm) Female/Rotating Adapter (PVC) 1200 PSI Contrast Line ARGON MEDICAL DEVICES, INC.
35 00886333207510 193368 193368 Contrast Line 60"(152cm) Female/Rotating Adapter (PVC) 1200 PSI Contrast Line ARGON MEDICAL DEVICES, INC.
36 00886333207503 193366 193366 Contrast Line 72"(183cm) Male/Female PVC 1200 PSI Contrast Line ARGON MEDICAL DEVICES, INC.
37 00886333207497 193365 193365 Contrast Line 48"(122cm) Female/Rotating Adapter Polyurethane, Braided 1200 PSI Contrast Line ARGON MEDICAL DEVICES, INC.
38 00886333207480 193364 193364 Contrast Line 30"(75cm) Female/Rotating Adapter Polyurethane, Braided 1200 PSI Contrast Line ARGON MEDICAL DEVICES, INC.
39 00886333207473 193363 193363 Contrast Line 20"(50cm) Female/Rotating Adapter Polyurethane, Braided 1200 PSI Contrast Line ARGON MEDICAL DEVICES, INC.
40 00886333207466 193362 193362 Contrast Line 10"(25cm) Female/Rotating Adapter Polyurethane, Braided 1200 PSI Contrast Line ARGON MEDICAL DEVICES, INC.
41 00886333207459 193361 193361 Contrast Line 48"(122cm) Male/Female Polyurethane, Braided 1200 PSI Contrast Line ARGON MEDICAL DEVICES, INC.
42 00886333207442 193360 193360 Contrast Line 30"(75cm) M/F (Braided) 1200 PSI Contrast Line ARGON MEDICAL DEVICES, INC.
43 00886333207435 193359 193359 Contrast Line 20"(50cm) M/F (Braided) 1200 PSI Contrast Line ARGON MEDICAL DEVICES, INC.
44 00886333207428 193358 193358 Contrast Line 10"(25cm) Male/Female Polyurethane, Braided 1200 PSI Contrast Line ARGON MEDICAL DEVICES, INC.
45 00886333207411 193357 193357 Contrast Line 48"(122cm) Female/Rotating Adapter PVC 1200 PSI Contrast Line ARGON MEDICAL DEVICES, INC.
46 00886333207404 193356 193356 Contrast Line 30"(75cm) Female/Rotating Adapter PVC 1200 PSI Contrast Line ARGON MEDICAL DEVICES, INC.
47 00886333207398 193355 193355 Contrast Line 20"(50cm) Female/Rotating Adapter PVC 1200 PSI Contrast Line ARGON MEDICAL DEVICES, INC.
48 00886333207381 193354 193354 Contrast Line 10"(25cm) Female/Rotating Adapter PVC 1200 PSI Contrast Line ARGON MEDICAL DEVICES, INC.
49 00886333207374 193353 193353 Contrast Line 48"(122cm) Male/Female PVC 1200 PSI Contrast Line ARGON MEDICAL DEVICES, INC.
50 00886333207367 193352 193352 Contrast Line 30"(75cm) Male/Female PVC 1200 PSI Contrast Line ARGON MEDICAL DEVICES, INC.