Other products from "NOVOSCI CORP."
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 B066SHC060 SHC06 SHC06 A collection of sterile devices including tubing and typically clamps, filters, A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device. DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass 2 1/2" X 3/32" X 72" TUBE PACK
2 B066SFC060 SFC06 SFC06 A collection of sterile devices including tubing and typically clamps, filters, A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device. DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass 2 3/8" X 3/32" X 72" TUBE PACK
3 B066C445B1 C445B C445B A plastic device designed to join two or more tubes of a cardiopulmonary bypass A plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KOC Accessories, Blood Circuit, Hemodialysis CONNECTOR, Y 1/2" X 3/8" X 3/8" W/LUER
4 B066C430S0 C430S C430S A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KOC Accessories, Blood Circuit, Hemodialysis Reducing Conector Y 3/8 x 1/4 x1/4
5 B066C335S0 C335S C335S A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KOC Accessories, Blood Circuit, Hemodialysis Equal Y Connector 3/8 w luer
6 B066C320S0 C320S C320S A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KOC Accessories, Blood Circuit, Hemodialysis Equal Y Connector 1/4
7 B066C310S0 C310S C310S A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KOC Accessories, Blood Circuit, Hemodialysis Equal Y Connector 3/16"
8 B066C245B1 C245B C245B A plastic device designed to join two or more tubes of a cardiopulmonary bypass A plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KOC Accessories, Blood Circuit, Hemodialysis CONNECTOR, REDUCER 3/8" X 1/2" W/LUER
9 B066C145S0 C145S C145S A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KOC Accessories, Blood Circuit, Hemodialysis Straight Connector 1/2 x 1/2 w luer
10 B066C130S0 C130S C130S A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KOC Accessories, Blood Circuit, Hemodialysis Straight Connector 3/8"
11 B066C115S0 C115S C115S A plastic device designed to join two or more tubes of a cardiopulmonary bypass A plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KOC Accessories, Blood Circuit, Hemodialysis CONNECTOR, STRAIGHT 3/16" x 3/16" W/LUER
12 B0664110060000 411006-000 411006-000 A sterile device designed to facilitate/regulate the delivery of cardioplegic so A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device. DTR Heat-Exchanger, Cardiopulmonary Bypass Cardioplegia Administration Set
13 B0664110050000 411005-000 411005-000 A sterile device designed to facilitate/regulate the delivery of cardioplegic so A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device. DTR Heat-Exchanger, Cardiopulmonary Bypass Life Gift Cardiopelgia Administration Set
14 B066342333NS1 342333NS 342333NS A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KRI Accessory Equipment, Cardiopulmonary Bypass CONN, Y 3/8" X 3/8" X 3/8 W/LUER
15 B066342222NS1 342222NS 342222NS A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KRI Accessory Equipment, Cardiopulmonary Bypass CONN, Y 1/4" X 1/4" X 1/4" W/LUER
16 B0663422220000 342222-000 342222-000 A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KRI Accessory Equipment, Cardiopulmonary Bypass CONN, Y 1/4" X 1/4" X 1/4" W/LUER
17 B066341344NS1 341344NS 341344NS A plastic device designed to join two or more tubes of a cardiopulmonary bypass A plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KRI Accessory Equipment, Cardiopulmonary Bypass CONNECTOR, Y 3/8" x 1/2" x 1/2" W/O LUER
18 B0663413440000 341344-000 341344-000 A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KRI Accessory Equipment, Cardiopulmonary Bypass CONN, Y 3/8" X 1/2" X 1/2" W/O LUER
19 B066341232NS1 341232NS 341232NS A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KRI Accessory Equipment, Cardiopulmonary Bypass CONN, Y 1/4" X 3/8" X 1/4" W/O LUER
20 B0663412320000 341232-000 341232-000 A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KRI Accessory Equipment, Cardiopulmonary Bypass CONN, Y 1/4" X 3/8" X 1/4" W/O LUER
21 B066331033NS1 331033NS 331033NS A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KRI Accessory Equipment, Cardiopulmonary Bypass CONN, 3/8" X 3/8" W/O PART LINE
22 B0663310330000 331033-000 331033-000 A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KRI Accessory Equipment, Cardiopulmonary Bypass CONN, 3/8" X 3/8" W/O PART LINE
23 B066301009NS1 301009NS 301009NS A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. DTL Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass CONN, 1/4" PERFUSION ADAPTER
24 B066321222NS1 321222NS 321222NS A sterile device designed to facilitate/regulate the delivery of cardioplegic so A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device. DTL Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass CONN, 1/4" X 1/4" X 1/4" CLEAR PAY
25 B0663110340000 311034-000 311034-000 A small, sterile device with a locking/holding mechanism designed to secure most A small, sterile device with a locking/holding mechanism designed to secure most any kind of tubing or tubing-like device (e.g., cables, cords) to a patient or to a surgical drape during a clinical intervention. It is typically designed as: 1) an adhesive pad (plaster), strip, or bandage intended to attach to the patient's skin or drape with the exposed side (top side) having an integrated fixation mechanism (e.g., Velcro hook/loop closure); or 2) a mechanical closure or gripping system intended to hold the tubing or tubing hub in place. This device is not designed to hold a specific type or brand of tubing. This is a single-use device. DTL Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass PEDIATRIC TUBING ORGANIZER - STERILE
26 B0663011240000 301124-000 301124-000 A sterile, semi-rigid tube used in open heart surgery to facilitate the transfer A sterile, semi-rigid tube used in open heart surgery to facilitate the transfer of priming fluids during the priming of the extracorporeal circuit of a cardiopulmonary bypass system. It is a noninvasive product in the form of a tube or tubing used to channel the fluids (i.e., primer/blood) to facilitate priming of the extracorporeal circuit and connection of the cardiopulmonary bypass system (heart/lung machine) to the patient. It is typically a moulded plastic tube with hard plastic spike at the distal end that connects to the bag or container of primer solution, a connector at the proximal end, and a central pinch clamp. This is a single-use device. DTL Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass QUICKIE PRIME - 24" W/CLAMP
27 B066301094NS1 301094NS 301094NS 1/2" TUBING TO FIT OVER THE CORONARY PERFUSION OULTET PORT OF AN OXYGENATOR, TO 1/2" TUBING TO FIT OVER THE CORONARY PERFUSION OULTET PORT OF AN OXYGENATOR, TO SECURELY SEAL OFF THE PORT, THUS REDUCING THE POSSIBILITY OF THE PORT BEING INADVERTENTLY OPENED DURING THE HEMOPERFUSION PROCEDURE. DTL Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass 1/2" CORONARY PERFUSION PLUG
28 B0663010940000 301094-000 301094-000 1/2 TUBING TO FIT OVER THE CORONARY PERFUSION OUTLET PORT OF AN OXYGENATOR, TO 1/2 TUBING TO FIT OVER THE CORONARY PERFUSION OUTLET PORT OF AN OXYGENATOR, TO SECURELY SEAL OFF THE PORT, THUS REDUCING THE POSSIBLITY OF THE PORT BEING INADVERTENTLY OPENED DUTING THE HEMOPERFUSION PROCEEDURE. DTL Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass 1/2" CORONARY PERFUSION PLUG
29 B0663010220000 301022-000 301022-000 A sterile device designed to facilitate/regulate the delivery of cardioplegic so A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device. DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass 24" 1/8 x 1/32 Perfusion Adaptor Set w/Clear 1/4" PAC Male Luer
30 B0663010120000 301012-000 301012-000 A sterile, semi-rigid tube used in open heart surgery to facilitate the transfer A sterile, semi-rigid tube used in open heart surgery to facilitate the transfer of priming fluids during the priming of the extracorporeal circuit of a cardiopulmonary bypass system. It is a noninvasive product in the form of a tube or tubing used to channel the fluids (i.e., primer/blood) to facilitate priming of the extracorporeal circuit and connection of the cardiopulmonary bypass system (heart/lung machine) to the patient. It is typically a moulded plastic tube with hard plastic spike at the distal end that connects to the bag or container of primer solution, a connector at the proximal end, and a central pinch clamp. This is a single-use device. DTL Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass QUICKIE PRIME - 1/4" X 3/32"
31 B0663010090000 301009-000 301009-000 A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. DTL Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass CONN, 1/4" PERFUSION ADAPTER
32 B0663010010000 301001-000 301001-000 A sterile, porous device used in the arterial line of an extracorporeal circuit, A sterile, porous device used in the arterial line of an extracorporeal circuit, during a cardiopulmonary bypass procedure, to trap and remove potentially harmful gaseous emboli, aggregated blood constituents, and particles greater than a specified size (e.g., 40 microns) to prevent them from flowing into the bloodstream and obstructing extracorporeal circulation. It is commonly referred to as a bubble trap and will typically be used for a specified length of time (e.g., 6 hours). This is a single-use device. KRI Accessory Equipment, Cardiopulmonary Bypass FILTER, GAS/OXYGEN
33 B0662013010000 201301-000 201301-000 A hand-held device designed to regulate and direct a stream of pressurized fluid A hand-held device designed to regulate and direct a stream of pressurized fluid (e.g., sterile water or saline) and as an alternative provide aspiration (suction), to a surgical site, for the purpose of irrigating and clearing debris from the field of intervention. It is fitted with a long syringe-like nozzle that is activated by the user, typically through a push-type control(s). This device is typically a component of a surgical irrigation/aspiration system used for ENT or neurological surgery. This is a single-use device. DTS Sucker, Cardiotomy Return, Cardiopulmonary Bypass Tonsil Tip Sucker
34 B0662010110000 201011-000 201011-000 A general-purpose valve that is used to regulate the direction of a liquid or a A general-purpose valve that is used to regulate the direction of a liquid or a gas flow. It is typically constructed of a durable material, e.g., plastic and/or metal, and may be used for a variety of general-purpose uses. For stopcocks used in intravenous (IV) lines for injection or removal of fluids see the appropriate GMDN code. This is a single-use device. DTZ Oxygenator, Cardiopulmonary Bypass STOPCOCK, TMP 3-WAY W/LUER LOCK
35 B066201010NS1 201010NS 201010NS A sharp bevel-edged, hollow tubular metal instrument designed to remove fluid fr A sharp bevel-edged, hollow tubular metal instrument designed to remove fluid from a body cavity or to obtain a biopsy specimen from a patient through aspiration; it is not dedicated to a particular part of the anatomy. The device is typically longer than a hypodermic needle and usually has a wider hub. It is not intended for administration of pharmaceuticals. This is a single-use device. DWS Instruments, Surgical, Cardiovascular MODIFIED AIR ASPIRATOR NEEDLE W/GREEN CAP
36 B066201035NS1 201035NS 201035NS An assembly of devices designed to evacuate fluid, tissue, gas, or other foreign An assembly of devices designed to evacuate fluid, tissue, gas, or other foreign materials from a body cavity or lumen by means of suction. It generally consists of a suction pump powered by compressed air or oxygen from a hospital's central gas system, tubing, plastic/glass collection container(s), a vacuum gauge, a regulator, an overflow trap, a moisture filter, and possibly a microbial filter. The pressurized gas enables the pump to create a vacuum in the suction tubing, which is inserted into the body for the removal of materials into the collection container. This system can be used in a wide variety of hospital or other healthcare settings. DTS Sucker, Cardiotomy Return, Cardiopulmonary Bypass ADULT GROOVED - TIP SUCKER
37 B0662010150000 201015-000 201015-000 A sterile, sharp bevel-edged, hollow tubular metal instrument designed to remove A sterile, sharp bevel-edged, hollow tubular metal instrument designed to remove fluid from a body cavity or to obtain a biopsy specimen from a patient through aspiration; it is not dedicated to a particular part of the anatomy. The device is typically longer than a hypodermic needle and usually has a wider hub. This is a single-use device. DWS Instruments, Surgical, Cardiovascular 18ga Pediatric Air Aspirator Needle w/Pink Cap
38 B066VAVRSCP0 VAVRSCP VAVRSCP A collection of sterile devices including tubing and typically clamps, filters, A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device. DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass 2 STANDARD VAVR CONVERSION PAC
39 B066SFC120 SFC12 SFC12 A collection of sterile devices including tubing and typically clamps, filters, A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device. DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass 2 3/8" X 3/32" X 144" TUBE PACK
40 B066SFC080 SFC08 SFC08 A collection of sterile devices including tubing and typically clamps, filters, A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device. DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass 3/8" X 3/32" X 96" TUBE PACK
41 B066SFB100 SFB10 SFB10 A collection of sterile devices including tubing and typically clamps, filters, A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device. DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass 2 3/8" X 1/16" X 120" TUBE PACK
42 B066SDC040 SDC04 SDC04 A collection of sterile devices including tubing and typically clamps, filters, A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device. DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass 2 1/4" X 3/32" X 48" TUBE PACK
43 B066SDB060 SDB06 SDB06 A collection of sterile devices including tubing and typically clamps, filters, A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device. DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass 1/4" X 1/16" X 72" TUBE PACK
44 B066SDB020 SDB02 SDB02 A collection of sterile devices including tubing and typically clamps, filters, A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device. DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass 2 1/4" X 1/16" X 24" TUBE PACK
45 B066SCB080 SCB08 SCB08 A collection of sterile devices including tubing and typically clamps, filters, A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device. DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass 2 3/16" X 1/16" X 96" TUBE PACK
46 B066RHC020 RHC02 RHC02 A collection of sterile devices including tubing and typically clamps, filters, A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device. DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass 2 1/2" X 3/32" BULK TUBING - 100 FEET
47 B066C490B1 C490B C490B A plastic device designed to join two or more tubes of a cardiopulmonary bypass A plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KOC Accessories, Blood Circuit, Hemodialysis CONNECTOR, Y 1/2" X 1/2" X 1/4"
48 B066C445S0 C445S C445S A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KOC Accessories, Blood Circuit, Hemodialysis Reducing Connector Y 1/2 x 3/8 x 3/8 w luer
49 B066C340S0 C340S C340S A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KOC Accessories, Blood Circuit, Hemodialysis Equal Y Connector 1/2
50 B066C240S0 C240S C240S A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. KOC Accessories, Blood Circuit, Hemodialysis Reducer Straight Connector 3/8 x 1/2
Other products with the same Product Code "DTL"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 M20682800 8280 The GATOR is intended to be used with 12F to 24F introducer sheaths to maintain The GATOR is intended to be used with 12F to 24F introducer sheaths to maintain a hemostatic seal around 0.035" or 0.038" guidewires. Gator® clipseal plug VASCULAR SOLUTIONS, INC.
2 M20682160 8216 Guardian® II NC hemostasis valve VASCULAR SOLUTIONS, INC.
3 M20682150 8215 The Guardian hemostasis valves are intended to maintain hemostasis during the us The Guardian hemostasis valves are intended to maintain hemostasis during the use of diagnostic or interventional devices. Guardian hemostasis valves are indicated for maintaining a seal around diagnostic/interventional devices with outside diameters up to 8F (0.105" or 2.67mm) during diagnostic/interventional procedures. Guardian® II NC hemostasis valve VASCULAR SOLUTIONS, INC.
4 M20682110 8211 The Guardian hemostasis valves are intended to maintain hemostasis during the us The Guardian hemostasis valves are intended to maintain hemostasis during the use of diagnostic or interventional devices. Guardian hemostasis valves are indicated for maintaining a seal around diagnostic/interventional devices with outside diameters up to 8F (0.105" or 2.67mm) during diagnostic/interventional procedures. The torque device is provided as an aid for steering the guidewire within the vascular anatomy. Guardian® II hemostasis valve VASCULAR SOLUTIONS, INC.
5 M20682100 8210 The Guardian hemostasis valves are intended to maintain hemostasis during the us The Guardian hemostasis valves are intended to maintain hemostasis during the use of diagnostic or interventional devices. Guardian hemostasis valves are indicated for maintaining a seal around diagnostic/interventional devices with outside diameters up to 8F (0.105" or 2.67mm) during diagnostic/interventional procedures. Guardian® II hemostasis valve VASCULAR SOLUTIONS, INC.
6 08717648013997 1003331 1003331 COPILOT Bleedback Control Valve Copilot ABBOTT VASCULAR INC.
7 08717648013973 1003327 1003327 COPILOT Kit includes Bleedback Control Valve 20/30 INDEFLATOR Inflation Device 3 COPILOT Kit includes Bleedback Control Valve 20/30 INDEFLATOR Inflation Device 30 atm 20 cc / Guide Wire Introducer / Torque Device Indeflator ABBOTT VASCULAR INC.
8 08717648013362 23242 23242 Rotating Hemostatic Valve .096" RHV ABBOTT VASCULAR INC.
9 08714729965787 H74939343020 H74939343020 Hemostasis Valve WATCHDOG™ BOSTON SCIENTIFIC CORPORATION
10 08714729734604 M001153220 Y-Adapter GateWay™ PLUS BOSTON SCIENTIFIC CORPORATION
11 08714729071280 H74904483100 Y-Adapter GateWay™ PLUS BOSTON SCIENTIFIC CORPORATION
12 H965914002350 91400235 Tri-Adaptor Kit NAMIC NAVILYST MEDICAL, INC.
13 H965914002310 91400231 Tri-Adaptor Kit NAMIC NAVILYST MEDICAL, INC.
14 H965914002280 91400228 Y-Adaptor Kit NAMIC NAVILYST MEDICAL, INC.
15 H965914002250 91400225 Y-Adaptor Kit NAMIC NAVILYST MEDICAL, INC.
16 H965914002210 91400221 Y-Adaptor Kit NAMIC NAVILYST MEDICAL, INC.
17 H965914000350 91400035 Tri-Adaptor NAMIC NAVILYST MEDICAL, INC.
18 H965914000310 91400031 Tri-Adaptor NAMIC NAVILYST MEDICAL, INC.
19 H965914000280 91400028 Y-Adaptor NAMIC NAVILYST MEDICAL, INC.
20 H965914000250 91400025 Y-Adaptor NAMIC NAVILYST MEDICAL, INC.
21 H965914000230 91400023 Y-Adaptor NAMIC NAVILYST MEDICAL, INC.
22 H965914000210 91400021 Y-Adaptor NAMIC NAVILYST MEDICAL, INC.
23 H965913013030 91301303 NAMIC Standard Angiographic Kit with 3 Valve Manifold, On Handles NAMIC NAVILYST MEDICAL, INC.
24 H965913013010 91301301 NAMIC Standard Angiographic Kit with 3 Valve Manifold, Off Handles NAMIC NAVILYST MEDICAL, INC.
25 H965814001240 81400124 Y-ADAPTOR,LG.BORE,FINE THREAD W/10" FLEXCIL EXT.-OEM NAMIC ANGIODYNAMICS, INC.
26 H965814001230 81400123 NAMIC 0.113" Large Bore Y-Adaptor NAMIC NAVILYST MEDICAL, INC.
27 H965814000250 81400025 NAMIC 0.125" Option 125 Y-Adaptor NAMIC NAVILYST MEDICAL, INC.
28 H965814000210 81400021 NAMIC 0.1" Y-Adaptor NAMIC NAVILYST MEDICAL, INC.
29 H965808000030 80800003 Male Luer Lock Fitting for SOSA Tubing NAMIC NAVILYST MEDICAL, INC.
30 H965807510040 80751004 NAMIC Male Vented Threaded Port Protector NAMIC NAVILYST MEDICAL, INC.
31 H965807510030 80751003 NAMIC Male-Female Vented Port Protector NAMIC NAVILYST MEDICAL, INC.
32 H965807510000 80751000 NAMIC Male Non Vented Threaded Port Protector NAMIC NAVILYST MEDICAL, INC.
33 H965807500000 80750000 NAMIC Male Non Vented Threaded Port Protector NAMIC NAVILYST MEDICAL, INC.
34 H965805169010 80516901 NAMIC Four-Way 200 psi Stopcock with 3 Female Luer Lockes NAMIC NAVILYST MEDICAL, INC.
35 H965805153510 80515351 NAMIC Three-Way 200 psi Stopcock with Rotating Collar NAMIC NAVILYST MEDICAL, INC.
36 H965805151120 80515112 NAMIC Three-Way 400 psi Stopcock with Rotating Collar NAMIC NAVILYST MEDICAL, INC.
37 H965800550170 80055017 NAMIC One-Way 1050 psi Stopcock with Fixed Male Luer Lock NAMIC NAVILYST MEDICAL, INC.
38 H965800550090 80055009 NAMIC Three-Way 1050 psi Stopcock with Rotating Adaptor NAMIC NAVILYST MEDICAL, INC.
39 H965800550080 80055008 NAMIC Three-Way 1050 psi Stopcock with Rotating Adaptor NAMIC NAVILYST MEDICAL, INC.
40 H965800550030 80055003 NAMIC Three-Way Stopcock 1050 psi with Fixed Male Luer Lock NAMIC NAVILYST MEDICAL, INC.
41 H965800393030 80039303 NAMIC Angiographic Medium Pressure 3 Valve Manifold, On Handles, Ports on Right NAMIC NAVILYST MEDICAL, INC.
42 H965800393010 80039301 NAMIC Angiographic Medium Pressure 3 Valve Manifold, Off Handles, Ports on Right NAMIC NAVILYST MEDICAL, INC.
43 H965800382120 80038212 NAMIC Angiographic Medium Pressure 2 Valve Manifold, Off Handles, Ports on Left NAMIC NAVILYST MEDICAL, INC.
44 H965800373010 80037301 NAMIC Angiographic High Pressure 3 Valve Manifold, Off Handles, Ports on Right NAMIC NAVILYST MEDICAL, INC.
45 H965800372020 80037202 NAMIC Angiographic High Pressure 2 Valve Manifold, On Handles, Ports on Right NAMIC NAVILYST MEDICAL, INC.
46 H965800350130 80035013 NAMIC Four-Way 400 psi Stopcock with Fixed Male Luer Lock NAMIC NAVILYST MEDICAL, INC.
47 H965800350090 80035009 NAMIC Three-Way 400 psi Stopcock with Rotating Adaptor NAMIC NAVILYST MEDICAL, INC.
48 H965800350080 80035008 NAMIC Three-Way 400 psi Stopcock with Rotating Adaptor NAMIC NAVILYST MEDICAL, INC.
49 H965800350020 80035002 NAMIC Three-Way 400 psi Stopcock with Rotating Collar NAMIC NAVILYST MEDICAL, INC.
50 H965800271800 80027180 NAMIC Male Luer Lock to Rotating Adaptor Connector NAMIC NAVILYST MEDICAL, INC.