A collection of sterile devices including tubing and typically clamps, filters,
A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device.
DWF
Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass
A collection of sterile devices including tubing and typically clamps, filters,
A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device.
DWF
Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass
A plastic device designed to join two or more tubes of a cardiopulmonary bypass
A plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device.
A sterile plastic device designed to join two or more tubes of a cardiopulmonary
A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device.
A sterile plastic device designed to join two or more tubes of a cardiopulmonary
A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device.
A sterile plastic device designed to join two or more tubes of a cardiopulmonary
A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device.
A sterile plastic device designed to join two or more tubes of a cardiopulmonary
A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device.
A plastic device designed to join two or more tubes of a cardiopulmonary bypass
A plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device.
A sterile plastic device designed to join two or more tubes of a cardiopulmonary
A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device.
A sterile plastic device designed to join two or more tubes of a cardiopulmonary
A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device.
A plastic device designed to join two or more tubes of a cardiopulmonary bypass
A plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device.
A sterile device designed to facilitate/regulate the delivery of cardioplegic so
A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device.
A sterile device designed to facilitate/regulate the delivery of cardioplegic so
A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device.
A sterile plastic device designed to join two or more tubes of a cardiopulmonary
A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device.
A sterile plastic device designed to join two or more tubes of a cardiopulmonary
A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device.
A sterile plastic device designed to join two or more tubes of a cardiopulmonary
A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device.
A plastic device designed to join two or more tubes of a cardiopulmonary bypass
A plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device.
A sterile plastic device designed to join two or more tubes of a cardiopulmonary
A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device.
A sterile plastic device designed to join two or more tubes of a cardiopulmonary
A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device.
A sterile plastic device designed to join two or more tubes of a cardiopulmonary
A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device.
A sterile plastic device designed to join two or more tubes of a cardiopulmonary
A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device.
A sterile plastic device designed to join two or more tubes of a cardiopulmonary
A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device.
A sterile plastic device designed to join two or more tubes of a cardiopulmonary
A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device.
A sterile device designed to facilitate/regulate the delivery of cardioplegic so
A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device.
A small, sterile device with a locking/holding mechanism designed to secure most
A small, sterile device with a locking/holding mechanism designed to secure most any kind of tubing or tubing-like device (e.g., cables, cords) to a patient or to a surgical drape during a clinical intervention. It is typically designed as: 1) an adhesive pad (plaster), strip, or bandage intended to attach to the patient's skin or drape with the exposed side (top side) having an integrated fixation mechanism (e.g., Velcro hook/loop closure); or 2) a mechanical closure or gripping system intended to hold the tubing or tubing hub in place. This device is not designed to hold a specific type or brand of tubing. This is a single-use device.
A sterile, semi-rigid tube used in open heart surgery to facilitate the transfer
A sterile, semi-rigid tube used in open heart surgery to facilitate the transfer of priming fluids during the priming of the extracorporeal circuit of a cardiopulmonary bypass system. It is a noninvasive product in the form of a tube or tubing used to channel the fluids (i.e., primer/blood) to facilitate priming of the extracorporeal circuit and connection of the cardiopulmonary bypass system (heart/lung machine) to the patient. It is typically a moulded plastic tube with hard plastic spike at the distal end that connects to the bag or container of primer solution, a connector at the proximal end, and a central pinch clamp. This is a single-use device.
1/2" TUBING TO FIT OVER THE CORONARY PERFUSION OULTET PORT OF AN OXYGENATOR, TO
1/2" TUBING TO FIT OVER THE CORONARY PERFUSION OULTET PORT OF AN OXYGENATOR, TO SECURELY SEAL OFF THE PORT, THUS REDUCING THE POSSIBILITY OF THE PORT BEING INADVERTENTLY OPENED DURING THE HEMOPERFUSION PROCEDURE.
1/2 TUBING TO FIT OVER THE CORONARY PERFUSION OUTLET PORT OF AN OXYGENATOR, TO
1/2 TUBING TO FIT OVER THE CORONARY PERFUSION OUTLET PORT OF AN OXYGENATOR, TO SECURELY SEAL OFF THE PORT, THUS REDUCING THE POSSIBLITY OF THE PORT BEING INADVERTENTLY OPENED DUTING THE HEMOPERFUSION PROCEEDURE.
A sterile device designed to facilitate/regulate the delivery of cardioplegic so
A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device.
DWF
Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass
24" 1/8 x 1/32 Perfusion Adaptor Set w/Clear 1/4" PAC Male Luer
A sterile, semi-rigid tube used in open heart surgery to facilitate the transfer
A sterile, semi-rigid tube used in open heart surgery to facilitate the transfer of priming fluids during the priming of the extracorporeal circuit of a cardiopulmonary bypass system. It is a noninvasive product in the form of a tube or tubing used to channel the fluids (i.e., primer/blood) to facilitate priming of the extracorporeal circuit and connection of the cardiopulmonary bypass system (heart/lung machine) to the patient. It is typically a moulded plastic tube with hard plastic spike at the distal end that connects to the bag or container of primer solution, a connector at the proximal end, and a central pinch clamp. This is a single-use device.
A sterile plastic device designed to join two or more tubes of a cardiopulmonary
A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device.
A sterile, porous device used in the arterial line of an extracorporeal circuit,
A sterile, porous device used in the arterial line of an extracorporeal circuit, during a cardiopulmonary bypass procedure, to trap and remove potentially harmful gaseous emboli, aggregated blood constituents, and particles greater than a specified size (e.g., 40 microns) to prevent them from flowing into the bloodstream and obstructing extracorporeal circulation. It is commonly referred to as a bubble trap and will typically be used for a specified length of time (e.g., 6 hours). This is a single-use device.
A hand-held device designed to regulate and direct a stream of pressurized fluid
A hand-held device designed to regulate and direct a stream of pressurized fluid (e.g., sterile water or saline) and as an alternative provide aspiration (suction), to a surgical site, for the purpose of irrigating and clearing debris from the field of intervention. It is fitted with a long syringe-like nozzle that is activated by the user, typically through a push-type control(s). This device is typically a component of a surgical irrigation/aspiration system used for ENT or neurological surgery. This is a single-use device.
A general-purpose valve that is used to regulate the direction of a liquid or a
A general-purpose valve that is used to regulate the direction of a liquid or a gas flow. It is typically constructed of a durable material, e.g., plastic and/or metal, and may be used for a variety of general-purpose uses. For stopcocks used in intravenous (IV) lines for injection or removal of fluids see the appropriate GMDN code. This is a single-use device.
A sharp bevel-edged, hollow tubular metal instrument designed to remove fluid fr
A sharp bevel-edged, hollow tubular metal instrument designed to remove fluid from a body cavity or to obtain a biopsy specimen from a patient through aspiration; it is not dedicated to a particular part of the anatomy. The device is typically longer than a hypodermic needle and usually has a wider hub. It is not intended for administration of pharmaceuticals. This is a single-use device.
An assembly of devices designed to evacuate fluid, tissue, gas, or other foreign
An assembly of devices designed to evacuate fluid, tissue, gas, or other foreign materials from a body cavity or lumen by means of suction. It generally consists of a suction pump powered by compressed air or oxygen from a hospital's central gas system, tubing, plastic/glass collection container(s), a vacuum gauge, a regulator, an overflow trap, a moisture filter, and possibly a microbial filter. The pressurized gas enables the pump to create a vacuum in the suction tubing, which is inserted into the body for the removal of materials into the collection container. This system can be used in a wide variety of hospital or other healthcare settings.
A sterile, sharp bevel-edged, hollow tubular metal instrument designed to remove
A sterile, sharp bevel-edged, hollow tubular metal instrument designed to remove fluid from a body cavity or to obtain a biopsy specimen from a patient through aspiration; it is not dedicated to a particular part of the anatomy. The device is typically longer than a hypodermic needle and usually has a wider hub. This is a single-use device.
A collection of sterile devices including tubing and typically clamps, filters,
A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device.
DWF
Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass
A collection of sterile devices including tubing and typically clamps, filters,
A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device.
DWF
Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass
A collection of sterile devices including tubing and typically clamps, filters,
A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device.
DWF
Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass
A collection of sterile devices including tubing and typically clamps, filters,
A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device.
DWF
Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass
A collection of sterile devices including tubing and typically clamps, filters,
A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device.
DWF
Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass
A collection of sterile devices including tubing and typically clamps, filters,
A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device.
DWF
Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass
A collection of sterile devices including tubing and typically clamps, filters,
A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device.
DWF
Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass
A collection of sterile devices including tubing and typically clamps, filters,
A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device.
DWF
Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass
A collection of sterile devices including tubing and typically clamps, filters,
A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device.
DWF
Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass
A plastic device designed to join two or more tubes of a cardiopulmonary bypass
A plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device.
A sterile plastic device designed to join two or more tubes of a cardiopulmonary
A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device.
A sterile plastic device designed to join two or more tubes of a cardiopulmonary
A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device.
A sterile plastic device designed to join two or more tubes of a cardiopulmonary
A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device.
The IBC Mini Sucker is a component of Blood Recovery Suction Systems for use in
The IBC Mini Sucker is a component of Blood Recovery Suction Systems for use in open heart procedures, autologus blood recovery or blood suction. It is a disposable, single use component.
The IBC Suction Wand is a component of Blood Recovery Suction Systems for use in
The IBC Suction Wand is a component of Blood Recovery Suction Systems for use in open heart procedures, autologus blood recovery or blood suction. It is a disposable, single use component.
Intracardiac Sucker, Adult Flat Handle at 40 Degree Angle, has 5/16" barbed end.
Intracardiac Sucker, Adult Flat Handle at 40 Degree Angle, has 5/16" barbed end. Works with the following tips Tips 1450-05 10.5 mm diameter, 1450-06 8.8 mm diameter, 1450-07 8.0 mm diameter, 1450-08 6.4 mm diameter, & 1480-03 7.0 mm diameter tip.
Intracardiac Sucker Tip, 7.0 mm diameter. Tips are grooved and slotted to allow
Intracardiac Sucker Tip, 7.0 mm diameter. Tips are grooved and slotted to allow for better flow and prevent clogging.For use with the Round Adult Handle 30 Degree Angle (1450-01), the Round Adult Handle 90 Degree Angle (1450-01-90) OR the Flat Adult Handle (1480-04)
Intracardiac Sucker Set with four Tips - Round, Flat Handle at 40 Degree Angle.
Intracardiac Sucker Set with four Tips - Round, Flat Handle at 40 Degree Angle. Comes with Adult Tips 1450-05 10.5 mm diameter, 1450-06 8.8 mm diameter, 1450-07 8.0 mm diameter, 1450-08 6.4 mm diameter; can also use 1480-03 7.0 mm diameter tip. NOTE: All tips also fit 1480-04 sucker handle. Tips are grooved and slotted to allow for better flow and prevent clogging. Suckers have 5/16" barbed end. * Handles and tips may be ordered as separate items.
Intracardiac Sucker Set with two Tips – Round, Pediatric Flat at 40 Degree Angle
Intracardiac Sucker Set with two Tips – Round, Pediatric Flat at 40 Degree Angle. Comes with Pediatric Tips 1450-15 6.4 mm diameter, 1450-16 4.0 mm diameter. Also fits 1450-17 2.0mm diameter & 1450-17L 2.0mm diameter long. 1450-15 Tip is grooved and slotted to allow for better flow and prevent clogging. Suckers have 5/16" barbed end. * Handles and tips may be ordered as separate items.
Intracardiac Sucker: Flat, Pediatric Handle Fixed Tip, 4.7 mm diameter. Handle
Intracardiac Sucker: Flat, Pediatric Handle Fixed Tip, 4.7 mm diameter. Handle is 11.0 inches long with a 40 Degree Angle. Tip is grooved and slotted to allow for better flow and prevent clogging. Suckers have 5/16" barbed end.
Intracardiac Sucker: Flat, Pediatric Handle Fixed Tip, 3.2 mm diameter. Handle
Intracardiac Sucker: Flat, Pediatric Handle Fixed Tip, 3.2 mm diameter. Handle is 7.5 inches long with a 30 Degree Angle. Tips are grooved and slotted to allow for better flow and prevent clogging. Suckers have 5/16" barbed end. Alternate tip and handle styles are available.
Intracardiac Sucker Set with two Tips – Round, Pediatric Handle at 90 Degree Ang
Intracardiac Sucker Set with two Tips – Round, Pediatric Handle at 90 Degree Angle. Comes with Pediatric Tips 1450-15 6.4 mm diameter, 1450-16 4.0 mm diameter. Also fits 1450-17 2.0mm diameter & 1450-17L 2.0mm diameter long. 1450-15 Tip is grooved and slotted to allow for better flow and prevent clogging. Suckers have 3/8" barbed end. * Handles and tips may be ordered as separate items.
Intracardiac Sucker Set with two Tips – Round, Pediatric Handle at 30 Degree Ang
Intracardiac Sucker Set with two Tips – Round, Pediatric Handle at 30 Degree Angle. Comes with Pediatric Tips 1450-15 6.4 mm diameter, 1450-16 4.0 mm diameter. Also fits 1450-17 2.0mm diameter & 1450-17L 2.0mm diameter long. 1450-15 Tip is grooved and slotted to allow for better flow and prevent clogging. Suckers have 3/8" barbed end. * Handles and tips may be ordered as separate items.
Intracardiac Sucker Set with four Tips - Round, Adult Handle at 90 Degree Angle.
Intracardiac Sucker Set with four Tips - Round, Adult Handle at 90 Degree Angle. Comes with Adult Tips 1450-05 10.5 mm diameter, 1450-06 8.8 mm diameter, 1450-07 8.0 mm diameter, 1450-08 6.4 mm diameter ; can also use 1480-03 7.0 mm diameter tip. NOTE: All tips also fit 1480-04 sucker handle. Tips are grooved and slotted to allow for better flow and prevent clogging. Suckers have 3/8" & 1/2" barbed end. * Handles and tips may be ordered as separate items.
Pediatric Intracardiac Sucker Tip - 2.0 mm diameter, Long. For use with the Rou
Pediatric Intracardiac Sucker Tip - 2.0 mm diameter, Long. For use with the Round Pediatric Handle 30 Degree Angle (1450JR-01), the Round Pediatric Handle 90 Degree Angle (1450JR-01-90), and Flat Pediatric Handle 40 Degree Angle (1470JR-01)
Pediatric Intracardiac Sucker Tip - 2.0 mm diameter. For use with the Round Ped
Pediatric Intracardiac Sucker Tip - 2.0 mm diameter. For use with the Round Pediatric Handle 30 Degree Angle (1450JR-01), the Round Pediatric Handle 90 Degree Angle (1450JR-01-90), and Flat Pediatric Handle 40 Degree Angle (1470JR-01)
Pediatric Intracardiac Sucker Tip - 4.0 mm diameter. For use with the Round Ped
Pediatric Intracardiac Sucker Tip - 4.0 mm diameter. For use with the Round Pediatric Handle 30 Degree Angle (1450JR-01), the Round Pediatric Handle 90 Degree Angle (1450JR-01-90), and Flat Pediatric Handle 40 Degree Angle (1470JR-01)
Pediatric Intracardiac Sucker Tip - 6.4 mm diameter. Tips are grooved and slott
Pediatric Intracardiac Sucker Tip - 6.4 mm diameter. Tips are grooved and slotted to allow for better flow and prevent clogging.For use with the Round Pediatric Handle 30 Degree Angle (1450JR-01), the Round Pediatric Handle 90 Degree Angle (1450JR-01-90), and Flat Pediatric Handle 40 Degree Angle (1470JR-01)
Adult Intracardiac Sucker Tip - 6.4 mm diameter. Tips are grooved and slotted t
Adult Intracardiac Sucker Tip - 6.4 mm diameter. Tips are grooved and slotted to allow for better flow and prevent clogging.For use with the Round Adult Handle 30 Degree Angle (1450-01), the Round Adult Handle 90 Degree Angle (1450-01-90) OR the Flat Adult Handle (1480-04)
Adult Intracardiac Sucker Tip - 8.0 mm diameter. Tips are grooved and slotted t
Adult Intracardiac Sucker Tip - 8.0 mm diameter. Tips are grooved and slotted to allow for better flow and prevent clogging.For use with the Round Adult Handle 30 Degree Angle (1450-01), the Round Adult Handle 90 Degree Angle (1450-01-90) OR the Flat Adult Handle (1480-04)
Adult Intracardiac Sucker Tip - 8.8 mm diameter. Tips are grooved and slotted t
Adult Intracardiac Sucker Tip - 8.8 mm diameter. Tips are grooved and slotted to allow for better flow and prevent clogging.For use with the Round Adult Handle 30 Degree Angle (1450-01), the Round Adult Handle 90 Degree Angle (1450-01-90) OR the Flat Adult Handle (1480-04)
Adult Intracardiac Sucker Tip - 10.5 mm diameter. Tips are grooved and slotted
Adult Intracardiac Sucker Tip - 10.5 mm diameter. Tips are grooved and slotted to allow for better flow and prevent clogging.For use with the Round Adult Handle 30 Degree Angle (1450-01), the Round Adult Handle 90 Degree Angle (1450-01-90) OR the Flat Adult Handle (1480-04)
Intracardiac Sucker, Adult Round Handle at 90 Degree Angle has 3/8" & 1/2" barbe
Intracardiac Sucker, Adult Round Handle at 90 Degree Angle has 3/8" & 1/2" barbed end. Works with the following tips Tips 1450-05 10.5 mm diameter, 1450-06 8.8 mm diameter, 1450-07 8.0 mm diameter, 1450-08 6.4 mm diameter, and 1480-03 7.0 mm diameter.
Intracardiac Sucker, Adult Round Handle at 30 Degree Angle, has 3/8" & 1/2" barb
Intracardiac Sucker, Adult Round Handle at 30 Degree Angle, has 3/8" & 1/2" barbed end. Works with the following tips Tips 1450-05 10.5 mm diameter, 1450-06 8.8 mm diameter, 1450-07 8.0 mm diameter, 1450-08 6.4 mm diameter, & 1480-03 7.0 mm diameter tip.
Intracardiac Sucker Set with four Tips - Round, Adult Handle at 30 Degree Angle.
Intracardiac Sucker Set with four Tips - Round, Adult Handle at 30 Degree Angle. Comes with Adult Tips 1450-05 10.5 mm diameter, 1450-06 8.8 mm diameter, 1450-07 8.0 mm diameter, 1450-08 6.4 mm diameter; can also use 1480-03 7.0 mm diameter tip. NOTE: All tips also fit 1480-04 sucker handle. Tips are grooved and slotted to allow for better flow and prevent clogging. Suckers have 3/8" & 1/2" barbed end. * Handles and tips may be ordered as separate items..
An assembly of devices designed to evacuate fluid, tissue, gas, or other foreign
An assembly of devices designed to evacuate fluid, tissue, gas, or other foreign materials from a body cavity or lumen by means of suction. It generally consists of a suction pump powered by compressed air or oxygen from a hospital's central gas system, tubing, plastic/glass collection container(s), a vacuum gauge, a regulator, an overflow trap, a moisture filter, and possibly a microbial filter. The pressurized gas enables the pump to create a vacuum in the suction tubing, which is inserted into the body for the removal of materials into the collection container. This system can be used in a wide variety of hospital or other healthcare settings.
A hand-held device designed to regulate and direct a stream of pressurized fluid
A hand-held device designed to regulate and direct a stream of pressurized fluid (e.g., sterile water or saline) and as an alternative provide aspiration (suction), to a surgical site, for the purpose of irrigating and clearing debris from the field of intervention. It is fitted with a long syringe-like nozzle that is activated by the user, typically through a push-type control(s). This device is typically a component of a surgical irrigation/aspiration system used for ENT or neurological surgery. This is a single-use device.
An assembly of devices designed to evacuate fluid, tissue, gas, or other foreign
An assembly of devices designed to evacuate fluid, tissue, gas, or other foreign materials from a body cavity or lumen by means of suction. It generally consists of a suction pump powered by compressed air or oxygen from a hospital's central gas system, tubing, plastic/glass collection container(s), a vacuum gauge, a regulator, an overflow trap, a moisture filter, and possibly a microbial filter. The pressurized gas enables the pump to create a vacuum in the suction tubing, which is inserted into the body for the removal of materials into the collection container. This system can be used in a wide variety of hospital or other healthcare settings.
A hand-held device designed to regulate and direct a stream of pressurized fluid
A hand-held device designed to regulate and direct a stream of pressurized fluid (e.g., sterile water or saline) and as an alternative provide aspiration (suction), to a surgical site, for the purpose of irrigating and clearing debris from the field of intervention. It is fitted with a long syringe-like nozzle that is activated by the user, typically through a push-type control(s). This device is typically a component of a surgical irrigation/aspiration system used for ENT or neurological surgery. This is a single-use device.
An assembly of devices designed to evacuate fluid, tissue, gas, or other foreign
An assembly of devices designed to evacuate fluid, tissue, gas, or other foreign materials from a body cavity or lumen by means of suction. It generally consists of a suction pump powered by compressed air or oxygen from a hospital's central gas system, tubing, plastic/glass collection container(s), a vacuum gauge, a regulator, an overflow trap, a moisture filter, and possibly a microbial filter. The pressurized gas enables the pump to create a vacuum in the suction tubing, which is inserted into the body for the removal of materials into the collection container. This system can be used in a wide variety of hospital or other healthcare settings.
A hand-held device designed to regulate and direct a stream of pressurized fluid
A hand-held device designed to regulate and direct a stream of pressurized fluid (e.g., sterile water or saline) and as an alternative provide aspiration (suction), to a surgical site, for the purpose of irrigating and clearing debris from the field of intervention. It is fitted with a long syringe-like nozzle that is activated by the user, typically through a push-type control(s). This device is typically a component of a surgical irrigation/aspiration system used for ENT or neurological surgery. This is a single-use device.
An assembly of devices designed to evacuate fluid, tissue, gas, or other foreign
An assembly of devices designed to evacuate fluid, tissue, gas, or other foreign materials from a body cavity or lumen by means of suction. It generally consists of a suction pump powered by compressed air or oxygen from a hospital's central gas system, tubing, plastic/glass collection container(s), a vacuum gauge, a regulator, an overflow trap, a moisture filter, and possibly a microbial filter. The pressurized gas enables the pump to create a vacuum in the suction tubing, which is inserted into the body for the removal of materials into the collection container. This system can be used in a wide variety of hospital or other healthcare settings.
A hand-held device designed to regulate and direct a stream of pressurized fluid
A hand-held device designed to regulate and direct a stream of pressurized fluid (e.g., sterile water or saline) and as an alternative provide aspiration (suction), to a surgical site, for the purpose of irrigating and clearing debris from the field of intervention. It is fitted with a long syringe-like nozzle that is activated by the user, typically through a push-type control(s). This device is typically a component of a surgical irrigation/aspiration system used for ENT or neurological surgery. This is a single-use device.
An assembly of devices designed to evacuate fluid, tissue, gas, or other foreign
An assembly of devices designed to evacuate fluid, tissue, gas, or other foreign materials from a body cavity or lumen by means of suction. It generally consists of a suction pump powered by compressed air or oxygen from a hospital's central gas system, tubing, plastic/glass collection container(s), a vacuum gauge, a regulator, an overflow trap, a moisture filter, and possibly a microbial filter. The pressurized gas enables the pump to create a vacuum in the suction tubing, which is inserted into the body for the removal of materials into the collection container. This system can be used in a wide variety of hospital or other healthcare settings.
A hand-held device designed to regulate and direct a stream of pressurized fluid
A hand-held device designed to regulate and direct a stream of pressurized fluid (e.g., sterile water or saline) and as an alternative provide aspiration (suction), to a surgical site, for the purpose of irrigating and clearing debris from the field of intervention. It is fitted with a long syringe-like nozzle that is activated by the user, typically through a push-type control(s). This device is typically a component of a surgical irrigation/aspiration system used for ENT or neurological surgery. This is a single-use device.
An assembly of devices designed to evacuate fluid, tissue, gas, or other foreign
An assembly of devices designed to evacuate fluid, tissue, gas, or other foreign materials from a body cavity or lumen by means of suction. It generally consists of a suction pump powered by compressed air or oxygen from a hospital's central gas system, tubing, plastic/glass collection container(s), a vacuum gauge, a regulator, an overflow trap, a moisture filter, and possibly a microbial filter. The pressurized gas enables the pump to create a vacuum in the suction tubing, which is inserted into the body for the removal of materials into the collection container. This system can be used in a wide variety of hospital or other healthcare settings.
A hand-held device designed to regulate and direct a stream of pressurized fluid
A hand-held device designed to regulate and direct a stream of pressurized fluid (e.g., sterile water or saline) and as an alternative provide aspiration (suction), to a surgical site, for the purpose of irrigating and clearing debris from the field of intervention. It is fitted with a long syringe-like nozzle that is activated by the user, typically through a push-type control(s). This device is typically a component of a surgical irrigation/aspiration system used for ENT or neurological surgery. This is a single-use device.
An assembly of devices designed to evacuate fluid, tissue, gas, or other foreign
An assembly of devices designed to evacuate fluid, tissue, gas, or other foreign materials from a body cavity or lumen by means of suction. It generally consists of a suction pump powered by compressed air or oxygen from a hospital's central gas system, tubing, plastic/glass collection container(s), a vacuum gauge, a regulator, an overflow trap, a moisture filter, and possibly a microbial filter. The pressurized gas enables the pump to create a vacuum in the suction tubing, which is inserted into the body for the removal of materials into the collection container. This system can be used in a wide variety of hospital or other healthcare settings.