Other products from "ORTHOPEDIC DESIGNS NORTH AMERICA, INC."
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 B058ODID105NS1 ODID105NS ODI-D105NS Trocar Tip Guide Wire, 1.6mm x 500mm (Threaded, Non-sterile) LXH Orthopedic Manual Surgical Instrument 1 Trocar Tip Guide Wire
2 B058ODID1051 ODID105 ODI-D105 Trocar Tip Guide Wire, 1.6mm x 500mm (Threaded) LXH Orthopedic Manual Surgical Instrument 1 Trocar Tip Guide Wire
3 B058ODID103NS1 ODID103NS ODI-D103NS Trocar Tip Guide Wire, 1.6mm x 500mm (Non-sterile) LXH Orthopedic Manual Surgical Instrument 1 Trocar Tip Guide Wire
4 B058ODID1031 ODID103 ODI-D103 Trocar Tip Guide Wire, 1.6mm x 500mm LXH Orthopedic Manual Surgical Instrument 1 Trocar Tip Guide Wire
5 B058HTN4103151 HTN410315 HTN-410-315 Talon™ DistalFix™ Humeral Nail 4° Ø10mm 315mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Humeral Nail
6 B058HTN4103001 HTN410300 HTN-410-300 Talon™ DistalFix™ Humeral Nail 4° Ø10mm 300mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Humeral Nail
7 B058HTN4102851 HTN410285 HTN-410-285 Talon™ DistalFix™ Humeral Nail 4° Ø10mm 285mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Humeral Nail
8 B058HTN4102701 HTN410270 HTN-410-270 Talon™ DistalFix™ Humeral Nail 4° Ø10mm 270mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Humeral Nail
9 B058HTN4102551 HTN410255 HTN-410-255 Talon™ DistalFix™ Humeral Nail 4° Ø10mm 255mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Humeral Nail
10 B058HTN4102401 HTN410240 HTN-410-240 Talon™ DistalFix™ Humeral Nail 4° Ø10mm 240mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Humeral Nail
11 B058HTN4102251 HTN410225 HTN-410-225 Talon™ DistalFix™ Humeral Nail 4° Ø10mm 225mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Humeral Nail
12 B058HTN4102101 HTN410210 HTN-410-210 Talon™ DistalFix™ Humeral Nail 4° Ø10mm 210mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Humeral Nail
13 B058HTN4101951 HTN410195 HTN-410-195 Talon™ DistalFix™ Humeral Nail 4° Ø10mm 195mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Humeral Nail
14 B058HTN4101801 HTN410180 HTN-410-180 Talon™ DistalFix™ Humeral Nail 4° Ø10mm 180mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Humeral Nail
15 B058HTN4101651 HTN410165 HTN-410-165 Talon™ DistalFix™ Humeral Nail 4° Ø10mm 165mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Humeral Nail
16 B058HTN4093151 HTN409315 HTN-409-315 Talon™ DistalFix™ Humeral Nail 4° Ø9mm 315mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Humeral Nail
17 B058HTN4093001 HTN409300 HTN-409-300 Talon™ DistalFix™ Humeral Nail 4° Ø9mm 300mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Humeral Nail
18 B058HTN4092851 HTN409285 HTN-409-285 Talon™ DistalFix™ Humeral Nail 4° Ø9mm 285mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Humeral Nail
19 B058HTN4092701 HTN409270 HTN-409-270 Talon™ DistalFix™ Humeral Nail 4° Ø9mm 270mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Humeral Nail
20 B058HTN4092551 HTN409255 HTN-409-255 Talon™ DistalFix™ Humeral Nail 4° Ø9mm 255mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Humeral Nail
21 B058HTN4092401 HTN409240 HTN-409-240 Talon™ DistalFix™ Humeral Nail 4° Ø9mm 240mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Humeral Nail
22 B058HTN4092251 HTN409225 HTN-409-225 Talon™ DistalFix™ Humeral Nail 4° Ø9mm 225mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Humeral Nail
23 B058HTN4092101 HTN409210 HTN-409-210 Talon™ DistalFix™ Humeral Nail 4° Ø9mm 210mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Humeral Nail
24 B058HTN4091951 HTN409195 HTN-409-195 Talon™ DistalFix™ Humeral Nail 4° Ø9mm 195mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Humeral Nail
25 B058HTN4091801 HTN409180 HTN-409-180 Talon™ DistalFix™ Humeral Nail 4° Ø9mm 180mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Humeral Nail
26 B058HTN4091651 HTN409165 HTN-409-165 Talon™ DistalFix™ Humeral Nail 4° Ø9mm 165mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Humeral Nail
27 B058HTN4083151 HTN408315 HTN-408-315 Talon™ DistalFix™ Humeral Nail 4° Ø8mm 315mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Humeral Nail
28 B058HTN4083001 HTN408300 HTN-408-300 Talon™ DistalFix™ Humeral Nail 4° Ø8mm 300mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Humeral Nail
29 B058HTN4082851 HTN408285 HTN-408-285 Talon™ DistalFix™ Humeral Nail 4° Ø8mm 285mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Humeral Nail
30 B058HTN4082701 HTN408270 HTN-408-270 Talon™ DistalFix™ Humeral Nail 4° Ø8mm 270mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Humeral Nail
31 B058HTN4082551 HTN408255 HTN-408-255 Talon™ DistalFix™ Humeral Nail 4° Ø8mm 255mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Humeral Nail
32 B058HTN4082401 HTN408240 HTN-408-240 Talon™ DistalFix™ Humeral Nail 4° Ø8mm 240mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Humeral Nail
33 B058HTN4082251 HTN408225 HTN-408-225 Talon™ DistalFix™ Humeral Nail 4° Ø8mm 225mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Humeral Nail
34 B058HTN4082101 HTN408210 HTN-408-210 Talon™ DistalFix™ Humeral Nail 4° Ø8mm 210mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Humeral Nail
35 B058HTN4081951 HTN408195 HTN-408-195 Talon™ DistalFix™ Humeral Nail 4° Ø8mm 195mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Humeral Nail
36 B058HTN4081801 HTN408180 HTN-408-180 Talon™ DistalFix™ Humeral Nail 4° Ø8mm 180mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Humeral Nail
37 B058HTN4081651 HTN408165 HTN-408-165 Talon™ DistalFix™ Humeral Nail 4° Ø8mm 165mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Humeral Nail
38 B058SLN0110801 SLN011080 Talon™ DistalFix™ Lag Screw 11mm x 80mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Lag Screw
39 B058THNT341 THNT34 THN-T34 Ball Tip Wire, 3mm x 900mm LXH Orthopedic Manual Surgical Instrument 1 Ball Tip Wire
40 B058SLN0110751 SLN011075 Talon™ DistalFix™ Lag Screw 11mm x 75mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Lag Screw
41 B058SLN0111201 SLN011120 Talon™ DistalFix™ Lag Screw 11mm x 120mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Lag Screw
42 B058SLN0111151 SLN011115 Talon™ DistalFix™ Lag Screw 11mm x 115mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Lag Screw
43 B058SLN0111101 SLN011110 Talon™ DistalFix™ Lag Screw 11mm x 110mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Lag Screw
44 B058SLN0111051 SLN011105 Talon™ DistalFix™ Lag Screw 11mm x 105mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Lag Screw
45 B058SLN0111001 SLN011100 Talon™ DistalFix™ Lag Screw 11mm x 100mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Lag Screw
46 B058SLN0110951 SLN011095 Talon™ DistalFix™ Lag Screw 11mm x 95mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Lag Screw
47 B058SLN0110901 SLN011090 Talon™ DistalFix™ Lag Screw 11mm x 90mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Lag Screw
48 B058SLN0110851 SLN011085 Talon™ DistalFix™ Lag Screw 11mm x 85mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Lag Screw
49 B058SLN0110701 SLN011070 Talon™ DistalFix™ Lag Screw 11mm x 70mm HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Lag Screw
50 B058SLN12538L1 SLN12538L Talon™ DistalFix™ Proximal Femoral Nail 125 Degree x 380mm, Left HSB Rod, Fixation, Intramedullary And Accessories 2 Talon™ DistalFix™ Proximal Femoral Nail
Other products with the same Product Code "JDS"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 07290109330204 Humeral Nail 1113530 The nail is intended for use in the fixation of long bone fractures, including d The nail is intended for use in the fixation of long bone fractures, including diaphyseal fractures. It is indicated for shaft fractures 5cm below the surgical neck, and 5cm proximal to the distal end of the medullary canal.Includes nail cap. Fixion Nailing System CARBOFIX ORTHOPEDICS LTD
2 07290109330198 Humeral Nail 1113528 The nail is intended for use in the fixation of long bone fractures, including d The nail is intended for use in the fixation of long bone fractures, including diaphyseal fractures. It is indicated for shaft fractures 5cm below the surgical neck, and 5cm proximal to the distal end of the medullary canal.Includes nail cap. Fixion Nailing System CARBOFIX ORTHOPEDICS LTD
3 07290109330181 Humeral Nail 1113526 The nail is intended for use in the fixation of long bone fractures, including d The nail is intended for use in the fixation of long bone fractures, including diaphyseal fractures. It is indicated for shaft fractures 5cm below the surgical neck, and 5cm proximal to the distal end of the medullary canal.Includes nail cap. Fixion Nailing System CARBOFIX ORTHOPEDICS LTD
4 07290109330174 Humeral Nail 1113524 The nail is intended for use in the fixation of long bone fractures, including d The nail is intended for use in the fixation of long bone fractures, including diaphyseal fractures. It is indicated for shaft fractures 5cm below the surgical neck, and 5cm proximal to the distal end of the medullary canal.Includes nail cap. Fixion Nailing System CARBOFIX ORTHOPEDICS LTD
5 07290109330167 Humeral Nail 1113522 The nail is intended for use in the fixation of long bone fractures, including d The nail is intended for use in the fixation of long bone fractures, including diaphyseal fractures. It is indicated for shaft fractures 5cm below the surgical neck, and 5cm proximal to the distal end of the medullary canal.Includes nail cap. Fixion Nailing System CARBOFIX ORTHOPEDICS LTD
6 07290109330150 Humeral Nail 1113520 The nail is intended for use in the fixation of long bone fractures, including d The nail is intended for use in the fixation of long bone fractures, including diaphyseal fractures. It is indicated for shaft fractures 5cm below the surgical neck, and 5cm proximal to the distal end of the medullary canal.Includes nail cap. Fixion Nailing System CARBOFIX ORTHOPEDICS LTD
7 07290109330143 Humeral Nail 1113518 The nail is intended for use in the fixation of long bone fractures, including d The nail is intended for use in the fixation of long bone fractures, including diaphyseal fractures. It is indicated for shaft fractures 5cm below the surgical neck, and 5cm proximal to the distal end of the medullary canal.Includes nail cap. Fixion Nailing System CARBOFIX ORTHOPEDICS LTD
8 07290109330136 Humeral Nail 1111030 The nail is intended for use in the fixation of long bone fractures, including d The nail is intended for use in the fixation of long bone fractures, including diaphyseal fractures. It is indicated for shaft fractures 5cm below the surgical neck, and 5cm proximal to the distal end of the medullary canal.Includes nail cap. Fixion Nailing System CARBOFIX ORTHOPEDICS LTD
9 07290109330129 Humeral Nail 1111028 The nail is intended for use in the fixation of long bone fractures, including d The nail is intended for use in the fixation of long bone fractures, including diaphyseal fractures. It is indicated for shaft fractures 5cm below the surgical neck, and 5cm proximal to the distal end of the medullary canal.Includes nail cap. Fixion Nailing System CARBOFIX ORTHOPEDICS LTD
10 07290109330112 Humeral Nail 1111026 The nail is intended for use in the fixation of long bone fractures, including d The nail is intended for use in the fixation of long bone fractures, including diaphyseal fractures. It is indicated for shaft fractures 5cm below the surgical neck, and 5cm proximal to the distal end of the medullary canal.Includes nail cap. Fixion Nailing System CARBOFIX ORTHOPEDICS LTD
11 07290109330105 Humeral Nail 1111024 The nail is intended for use in the fixation of long bone fractures, including d The nail is intended for use in the fixation of long bone fractures, including diaphyseal fractures. It is indicated for shaft fractures 5cm below the surgical neck, and 5cm proximal to the distal end of the medullary canal.Includes nail cap. Fixion Nailing System CARBOFIX ORTHOPEDICS LTD
12 07290109330099 Humeral Nail 1111022 The nail is intended for use in the fixation of long bone fractures, including d The nail is intended for use in the fixation of long bone fractures, including diaphyseal fractures. It is indicated for shaft fractures 5cm below the surgical neck, and 5cm proximal to the distal end of the medullary canal.Includes nail cap. Fixion Nailing System CARBOFIX ORTHOPEDICS LTD
13 07290109330082 Humeral Nail 1111020 The nail is intended for use in the fixation of long bone fractures, including d The nail is intended for use in the fixation of long bone fractures, including diaphyseal fractures. It is indicated for shaft fractures 5cm below the surgical neck, and 5cm proximal to the distal end of the medullary canal.Includes nail cap. Fixion Nailing System CARBOFIX ORTHOPEDICS LTD
14 07290109330075 Humeral Nail 1111018 The nail is intended for use in the fixation of long bone fractures, including d The nail is intended for use in the fixation of long bone fractures, including diaphyseal fractures. It is indicated for shaft fractures 5cm below the surgical neck, and 5cm proximal to the distal end of the medullary canal.Includes nail cap. Fixion Nailing System CARBOFIX ORTHOPEDICS LTD
15 07290109330068 Humeral Nail 1110030 The nail is intended for use in the fixation of long bone fractures, including d The nail is intended for use in the fixation of long bone fractures, including diaphyseal fractures. It is indicated for shaft fractures 5cm below the surgical neck, and 5cm proximal to the distal end of the medullary canal.Includes nail cap. Fixion Nailing System CARBOFIX ORTHOPEDICS LTD
16 07290109330051 Humeral Nail 1110028 The nail is intended for use in the fixation of long bone fractures, including d The nail is intended for use in the fixation of long bone fractures, including diaphyseal fractures. It is indicated for shaft fractures 5cm below the surgical neck, and 5cm proximal to the distal end of the medullary canal.Includes nail cap. Fixion Nailing System CARBOFIX ORTHOPEDICS LTD
17 07290109330044 Humeral Nail 1110026 The nail is intended for use in the fixation of long bone fractures, including d The nail is intended for use in the fixation of long bone fractures, including diaphyseal fractures. It is indicated for shaft fractures 5cm below the surgical neck, and 5cm proximal to the distal end of the medullary canal.Includes nail cap. Fixion Nailing System CARBOFIX ORTHOPEDICS LTD
18 07290109330037 Humeral Nail 1110024 The nail is intended for use in the fixation of long bone fractures, including d The nail is intended for use in the fixation of long bone fractures, including diaphyseal fractures. It is indicated for shaft fractures 5cm below the surgical neck, and 5cm proximal to the distal end of the medullary canal.Includes nail cap. Fixion Nailing System CARBOFIX ORTHOPEDICS LTD
19 07290109330020 Humeral Nail 1110022 The nail is intended for use in the fixation of long bone fractures, including d The nail is intended for use in the fixation of long bone fractures, including diaphyseal fractures. It is indicated for shaft fractures 5cm below the surgical neck, and 5cm proximal to the distal end of the medullary canal.Includes nail cap. Fixion Nailing System CARBOFIX ORTHOPEDICS LTD
20 07290109330013 Humeral Nail 1110020 The nail is intended for use in the fixation of long bone fractures, including d The nail is intended for use in the fixation of long bone fractures, including diaphyseal fractures. It is indicated for shaft fractures 5cm below the surgical neck, and 5cm proximal to the distal end of the medullary canal.Includes nail cap. Fixion Nailing System CARBOFIX ORTHOPEDICS LTD
21 07290109330006 Humeral Nail 1110018 The nail is intended for use in the fixation of long bone fractures, including d The nail is intended for use in the fixation of long bone fractures, including diaphyseal fractures. It is indicated for shaft fractures 5cm below the surgical neck, and 5cm proximal to the distal end of the medullary canal.Includes nail cap. Fixion Nailing System CARBOFIX ORTHOPEDICS LTD
22 04047844111994 Anvil PBZ0001-12 The SACRONAIL system provides a sustained, stable restoration of dorsal pelvic f The SACRONAIL system provides a sustained, stable restoration of dorsal pelvic fractures and sacral fractures through its intraosseous location and its direct, bi-iliac symmetric anchorage. The implant consists of a nail of various lengths from135mm to 194mm with a constant diameter of 8mm and 2 locking screws in different lengths. This variation ensures adaptation to the respective anatomy of the patient. The intersections of the screw axes to the implant axis have a distance of 15mm to the respective end face of the nail. This ensures a solid support on the lateral cortex of the Ilia. The angle of the screw axes to the implant axis corresponds to the anatomical conditions and is 70°. The locking screw ensures a stable connection of the components. The tips of the locking screws are rounded to facilitate insertion into the nail while the dorsal ends of locking screws are a hexagon. The caps serve to close the instrument connection of the nail. The implants are made from the Titanium alloy (Ti6Al4V) according to ASTM F 136 / ISO 5832-3, with a Type II anodization according to AMS 2488. There are Instruments which are specific to the implantation of the SACRONAIL device. These include, but are not limited to, the Guide Frame, the Guide Bracket, the Fixation Bracket, various Instrument Guides, various dilators and drills, screwdrivers as well as the specific tools for revision of the device. SACRONAIL SIGNUS MEDIZINTECHNIK GMBH
23 04047844111987 Aiming device PBZ0001-1-B The SACRONAIL system provides a sustained, stable restoration of dorsal pelvic f The SACRONAIL system provides a sustained, stable restoration of dorsal pelvic fractures and sacral fractures through its intraosseous location and its direct, bi-iliac symmetric anchorage. The implant consists of a nail of various lengths from135mm to 194mm with a constant diameter of 8mm and 2 locking screws in different lengths. This variation ensures adaptation to the respective anatomy of the patient. The intersections of the screw axes to the implant axis have a distance of 15mm to the respective end face of the nail. This ensures a solid support on the lateral cortex of the Ilia. The angle of the screw axes to the implant axis corresponds to the anatomical conditions and is 70°. The locking screw ensures a stable connection of the components. The tips of the locking screws are rounded to facilitate insertion into the nail while the dorsal ends of locking screws are a hexagon. The caps serve to close the instrument connection of the nail. The implants are made from the Titanium alloy (Ti6Al4V) according to ASTM F 136 / ISO 5832-3, with a Type II anodization according to AMS 2488. There are Instruments which are specific to the implantation of the SACRONAIL device. These include, but are not limited to, the Guide Frame, the Guide Bracket, the Fixation Bracket, various Instrument Guides, various dilators and drills, screwdrivers as well as the specific tools for revision of the device. SACRONAIL SIGNUS MEDIZINTECHNIK GMBH
24 04047844101216 Screw pelvic nail PBZ0001-8-A The SACRONAIL system provides a sustained, stable restoration of dorsal pelvic f The SACRONAIL system provides a sustained, stable restoration of dorsal pelvic fractures and sacral fractures through its intraosseous location and its direct, bi-iliac symmetric anchorage. The implant consists of a nail of various lengths from135mm to 194mm with a constant diameter of 8mm and 2 locking screws in different lengths. This variation ensures adaptation to the respective anatomy of the patient. The intersections of the screw axes to the implant axis have a distance of 15mm to the respective end face of the nail. This ensures a solid support on the lateral cortex of the Ilia. The angle of the screw axes to the implant axis corresponds to the anatomical conditions and is 70°. The locking screw ensures a stable connection of the components. The tips of the locking screws are rounded to facilitate insertion into the nail while the dorsal ends of locking screws are a hexagon. The caps serve to close the instrument connection of the nail. The implants are made from the Titanium alloy (Ti6Al4V) according to ASTM F 136 / ISO 5832-3, with a Type II anodization according to AMS 2488. There are Instruments which are specific to the implantation of the SACRONAIL device. These include, but are not limited to, the Guide Frame, the Guide Bracket, the Fixation Bracket, various Instrument Guides, various dilators and drills, screwdrivers as well as the specific tools for revision of the device. SACRONAIL SIGNUS MEDIZINTECHNIK GMBH
25 04047844101209 Compression sleeve, tip PBZ0001-11-A The SACRONAIL system provides a sustained, stable restoration of dorsal pelvic f The SACRONAIL system provides a sustained, stable restoration of dorsal pelvic fractures and sacral fractures through its intraosseous location and its direct, bi-iliac symmetric anchorage. The implant consists of a nail of various lengths from135mm to 194mm with a constant diameter of 8mm and 2 locking screws in different lengths. This variation ensures adaptation to the respective anatomy of the patient. The intersections of the screw axes to the implant axis have a distance of 15mm to the respective end face of the nail. This ensures a solid support on the lateral cortex of the Ilia. The angle of the screw axes to the implant axis corresponds to the anatomical conditions and is 70°. The locking screw ensures a stable connection of the components. The tips of the locking screws are rounded to facilitate insertion into the nail while the dorsal ends of locking screws are a hexagon. The caps serve to close the instrument connection of the nail. The implants are made from the Titanium alloy (Ti6Al4V) according to ASTM F 136 / ISO 5832-3, with a Type II anodization according to AMS 2488. There are Instruments which are specific to the implantation of the SACRONAIL device. These include, but are not limited to, the Guide Frame, the Guide Bracket, the Fixation Bracket, various Instrument Guides, various dilators and drills, screwdrivers as well as the specific tools for revision of the device. SACRONAIL SIGNUS MEDIZINTECHNIK GMBH
26 04047844062937 Screw plug PBK080020/S DescriptionThe SACRONAIL system provides a sustained, stable restoration of dors DescriptionThe SACRONAIL system provides a sustained, stable restoration of dorsal pelvic fractures and sacral fractures through its intraosseous location and its direct, bi-iliac symmetric anchorage. The implant consists of a nail of various lengths from135mm to 194mm with a constant diameter of 8mm and 2 locking screws in different lengths. This variation ensures adaptation to the respective anatomy of the patient. The intersections of the screw axes to the implant axis have a distance of 15mm to the respective end face of the nail. This ensures a solid support on the lateral cortex of the Ilia. The angle of the screw axes to the implant axis corresponds to the anatomical conditions and is 70°. The locking screw ensures a stable connection of the components. The tips of the locking screws are rounded to facilitate insertion into the nail while the dorsal ends of locking screws are a hexagon. The caps serve to close the instrument connection of the nail. The implants are made from the Titanium alloy (Ti6Al4V) according to ASTM F 136 / ISO 5832-3, with a Type II anodization according to AMS 2488. There are Instruments which are specific to the implantation of the SACRONAIL device. These include, but are not limited to, the Guide Frame, the Guide Bracket, the Fixation Bracket, various Instrument Guides, various dilators and drills, screwdrivers as well as the specific tools for revision of the device. SACRONAIL SIGNUS MEDIZINTECHNIK GMBH
27 04047844062920 Screw plug PBK080005/S DescriptionThe SACRONAIL system provides a sustained, stable restoration of dors DescriptionThe SACRONAIL system provides a sustained, stable restoration of dorsal pelvic fractures and sacral fractures through its intraosseous location and its direct, bi-iliac symmetric anchorage. The implant consists of a nail of various lengths from135mm to 194mm with a constant diameter of 8mm and 2 locking screws in different lengths. This variation ensures adaptation to the respective anatomy of the patient. The intersections of the screw axes to the implant axis have a distance of 15mm to the respective end face of the nail. This ensures a solid support on the lateral cortex of the Ilia. The angle of the screw axes to the implant axis corresponds to the anatomical conditions and is 70°. The locking screw ensures a stable connection of the components. The tips of the locking screws are rounded to facilitate insertion into the nail while the dorsal ends of locking screws are a hexagon. The caps serve to close the instrument connection of the nail. The implants are made from the Titanium alloy (Ti6Al4V) according to ASTM F 136 / ISO 5832-3, with a Type II anodization according to AMS 2488. There are Instruments which are specific to the implantation of the SACRONAIL device. These include, but are not limited to, the Guide Frame, the Guide Bracket, the Fixation Bracket, various Instrument Guides, various dilators and drills, screwdrivers as well as the specific tools for revision of the device. SACRONAIL SIGNUS MEDIZINTECHNIK GMBH
28 04047844057704 Clamping screw PBZ0001-9 The SACRONAIL system provides a sustained, stable restoration of dorsal pelvic f The SACRONAIL system provides a sustained, stable restoration of dorsal pelvic fractures and sacral fractures through its intraosseous location and its direct, bi-iliac symmetric anchorage. The implant consists of a nail of various lengths from135mm to 194mm with a constant diameter of 8mm and 2 locking screws in different lengths. This variation ensures adaptation to the respective anatomy of the patient. The intersections of the screw axes to the implant axis have a distance of 15mm to the respective end face of the nail. This ensures a solid support on the lateral cortex of the Ilia. The angle of the screw axes to the implant axis corresponds to the anatomical conditions and is 70°. The locking screw ensures a stable connection of the components. The tips of the locking screws are rounded to facilitate insertion into the nail while the dorsal ends of locking screws are a hexagon. The caps serve to close the instrument connection of the nail. The implants are made from the Titanium alloy (Ti6Al4V) according to ASTM F 136 / ISO 5832-3, with a Type II anodization according to AMS 2488. There are Instruments which are specific to the implantation of the SACRONAIL device. These include, but are not limited to, the Guide Frame, the Guide Bracket, the Fixation Bracket, various Instrument Guides, various dilators and drills, screwdrivers as well as the specific tools for revision of the device. SACRONAIL SIGNUS MEDIZINTECHNIK GMBH
29 04047844057681 Fixation screw PBZ0001-7 The SACRONAIL system provides a sustained, stable restoration of dorsal pelvic f The SACRONAIL system provides a sustained, stable restoration of dorsal pelvic fractures and sacral fractures through its intraosseous location and its direct, bi-iliac symmetric anchorage. The implant consists of a nail of various lengths from135mm to 194mm with a constant diameter of 8mm and 2 locking screws in different lengths. This variation ensures adaptation to the respective anatomy of the patient. The intersections of the screw axes to the implant axis have a distance of 15mm to the respective end face of the nail. This ensures a solid support on the lateral cortex of the Ilia. The angle of the screw axes to the implant axis corresponds to the anatomical conditions and is 70°. The locking screw ensures a stable connection of the components. The tips of the locking screws are rounded to facilitate insertion into the nail while the dorsal ends of locking screws are a hexagon. The caps serve to close the instrument connection of the nail. The implants are made from the Titanium alloy (Ti6Al4V) according to ASTM F 136 / ISO 5832-3, with a Type II anodization according to AMS 2488. There are Instruments which are specific to the implantation of the SACRONAIL device. These include, but are not limited to, the Guide Frame, the Guide Bracket, the Fixation Bracket, various Instrument Guides, various dilators and drills, screwdrivers as well as the specific tools for revision of the device. SACRONAIL SIGNUS MEDIZINTECHNIK GMBH
30 04047844057674 Fixation arm PBZ0001-6 The SACRONAIL system provides a sustained, stable restoration of dorsal pelvic f The SACRONAIL system provides a sustained, stable restoration of dorsal pelvic fractures and sacral fractures through its intraosseous location and its direct, bi-iliac symmetric anchorage. The implant consists of a nail of various lengths from135mm to 194mm with a constant diameter of 8mm and 2 locking screws in different lengths. This variation ensures adaptation to the respective anatomy of the patient. The intersections of the screw axes to the implant axis have a distance of 15mm to the respective end face of the nail. This ensures a solid support on the lateral cortex of the Ilia. The angle of the screw axes to the implant axis corresponds to the anatomical conditions and is 70°. The locking screw ensures a stable connection of the components. The tips of the locking screws are rounded to facilitate insertion into the nail while the dorsal ends of locking screws are a hexagon. The caps serve to close the instrument connection of the nail. The implants are made from the Titanium alloy (Ti6Al4V) according to ASTM F 136 / ISO 5832-3, with a Type II anodization according to AMS 2488. There are Instruments which are specific to the implantation of the SACRONAIL device. These include, but are not limited to, the Guide Frame, the Guide Bracket, the Fixation Bracket, various Instrument Guides, various dilators and drills, screwdrivers as well as the specific tools for revision of the device. SACRONAIL SIGNUS MEDIZINTECHNIK GMBH
31 04047844057667 Instrument guide PBZ0001-5 The SACRONAIL system provides a sustained, stable restoration of dorsal pelvic f The SACRONAIL system provides a sustained, stable restoration of dorsal pelvic fractures and sacral fractures through its intraosseous location and its direct, bi-iliac symmetric anchorage. The implant consists of a nail of various lengths from135mm to 194mm with a constant diameter of 8mm and 2 locking screws in different lengths. This variation ensures adaptation to the respective anatomy of the patient. The intersections of the screw axes to the implant axis have a distance of 15mm to the respective end face of the nail. This ensures a solid support on the lateral cortex of the Ilia. The angle of the screw axes to the implant axis corresponds to the anatomical conditions and is 70°. The locking screw ensures a stable connection of the components. The tips of the locking screws are rounded to facilitate insertion into the nail while the dorsal ends of locking screws are a hexagon. The caps serve to close the instrument connection of the nail. The implants are made from the Titanium alloy (Ti6Al4V) according to ASTM F 136 / ISO 5832-3, with a Type II anodization according to AMS 2488. There are Instruments which are specific to the implantation of the SACRONAIL device. These include, but are not limited to, the Guide Frame, the Guide Bracket, the Fixation Bracket, various Instrument Guides, various dilators and drills, screwdrivers as well as the specific tools for revision of the device. SACRONAIL SIGNUS MEDIZINTECHNIK GMBH
32 04047844057650 Instrument guide PBZ0001-4 The SACRONAIL system provides a sustained, stable restoration of dorsal pelvic f The SACRONAIL system provides a sustained, stable restoration of dorsal pelvic fractures and sacral fractures through its intraosseous location and its direct, bi-iliac symmetric anchorage. The implant consists of a nail of various lengths from135mm to 194mm with a constant diameter of 8mm and 2 locking screws in different lengths. This variation ensures adaptation to the respective anatomy of the patient. The intersections of the screw axes to the implant axis have a distance of 15mm to the respective end face of the nail. This ensures a solid support on the lateral cortex of the Ilia. The angle of the screw axes to the implant axis corresponds to the anatomical conditions and is 70°. The locking screw ensures a stable connection of the components. The tips of the locking screws are rounded to facilitate insertion into the nail while the dorsal ends of locking screws are a hexagon. The caps serve to close the instrument connection of the nail. The implants are made from the Titanium alloy (Ti6Al4V) according to ASTM F 136 / ISO 5832-3, with a Type II anodization according to AMS 2488. There are Instruments which are specific to the implantation of the SACRONAIL device. These include, but are not limited to, the Guide Frame, the Guide Bracket, the Fixation Bracket, various Instrument Guides, various dilators and drills, screwdrivers as well as the specific tools for revision of the device. SACRONAIL SIGNUS MEDIZINTECHNIK GMBH
33 04047844057643 Instrument guide PBZ0001-3 The SACRONAIL system provides a sustained, stable restoration of dorsal pelvic f The SACRONAIL system provides a sustained, stable restoration of dorsal pelvic fractures and sacral fractures through its intraosseous location and its direct, bi-iliac symmetric anchorage. The implant consists of a nail of various lengths from135mm to 194mm with a constant diameter of 8mm and 2 locking screws in different lengths. This variation ensures adaptation to the respective anatomy of the patient. The intersections of the screw axes to the implant axis have a distance of 15mm to the respective end face of the nail. This ensures a solid support on the lateral cortex of the Ilia. The angle of the screw axes to the implant axis corresponds to the anatomical conditions and is 70°. The locking screw ensures a stable connection of the components. The tips of the locking screws are rounded to facilitate insertion into the nail while the dorsal ends of locking screws are a hexagon. The caps serve to close the instrument connection of the nail. The implants are made from the Titanium alloy (Ti6Al4V) according to ASTM F 136 / ISO 5832-3, with a Type II anodization according to AMS 2488. There are Instruments which are specific to the implantation of the SACRONAIL device. These include, but are not limited to, the Guide Frame, the Guide Bracket, the Fixation Bracket, various Instrument Guides, various dilators and drills, screwdrivers as well as the specific tools for revision of the device. SACRONAIL SIGNUS MEDIZINTECHNIK GMBH
34 04047844057636 Instrument guide PBZ0001-2 The SACRONAIL system provides a sustained, stable restoration of dorsal pelvic f The SACRONAIL system provides a sustained, stable restoration of dorsal pelvic fractures and sacral fractures through its intraosseous location and its direct, bi-iliac symmetric anchorage. The implant consists of a nail of various lengths from135mm to 194mm with a constant diameter of 8mm and 2 locking screws in different lengths. This variation ensures adaptation to the respective anatomy of the patient. The intersections of the screw axes to the implant axis have a distance of 15mm to the respective end face of the nail. This ensures a solid support on the lateral cortex of the Ilia. The angle of the screw axes to the implant axis corresponds to the anatomical conditions and is 70°. The locking screw ensures a stable connection of the components. The tips of the locking screws are rounded to facilitate insertion into the nail while the dorsal ends of locking screws are a hexagon. The caps serve to close the instrument connection of the nail. The implants are made from the Titanium alloy (Ti6Al4V) according to ASTM F 136 / ISO 5832-3, with a Type II anodization according to AMS 2488. There are Instruments which are specific to the implantation of the SACRONAIL device. These include, but are not limited to, the Guide Frame, the Guide Bracket, the Fixation Bracket, various Instrument Guides, various dilators and drills, screwdrivers as well as the specific tools for revision of the device. SACRONAIL SIGNUS MEDIZINTECHNIK GMBH
35 04047844057612 Compression sleeve, handle PBZ0001-10 The SACRONAIL system provides a sustained, stable restoration of dorsal pelvic f The SACRONAIL system provides a sustained, stable restoration of dorsal pelvic fractures and sacral fractures through its intraosseous location and its direct, bi-iliac symmetric anchorage. The implant consists of a nail of various lengths from135mm to 194mm with a constant diameter of 8mm and 2 locking screws in different lengths. This variation ensures adaptation to the respective anatomy of the patient. The intersections of the screw axes to the implant axis have a distance of 15mm to the respective end face of the nail. This ensures a solid support on the lateral cortex of the Ilia. The angle of the screw axes to the implant axis corresponds to the anatomical conditions and is 70°. The locking screw ensures a stable connection of the components. The tips of the locking screws are rounded to facilitate insertion into the nail while the dorsal ends of locking screws are a hexagon. The caps serve to close the instrument connection of the nail. The implants are made from the Titanium alloy (Ti6Al4V) according to ASTM F 136 / ISO 5832-3, with a Type II anodization according to AMS 2488. There are Instruments which are specific to the implantation of the SACRONAIL device. These include, but are not limited to, the Guide Frame, the Guide Bracket, the Fixation Bracket, various Instrument Guides, various dilators and drills, screwdrivers as well as the specific tools for revision of the device. SACRONAIL SIGNUS MEDIZINTECHNIK GMBH
36 04047844039922 Pelvic nail PBX080194 DescriptionThe SACRONAIL system provides a sustained, stable restoration of dors DescriptionThe SACRONAIL system provides a sustained, stable restoration of dorsal pelvic fractures and sacral fractures through its intraosseous location and its direct, bi-iliac symmetric anchorage. The implant consists of a nail of various lengths from135mm to 194mm with a constant diameter of 8mm and 2 locking screws in different lengths. This variation ensures adaptation to the respective anatomy of the patient. The intersections of the screw axes to the implant axis have a distance of 15mm to the respective end face of the nail. This ensures a solid support on the lateral cortex of the Ilia. The angle of the screw axes to the implant axis corresponds to the anatomical conditions and is 70°. The locking screw ensures a stable connection of the components. The tips of the locking screws are rounded to facilitate insertion into the nail while the dorsal ends of locking screws are a hexagon. The caps serve to close the instrument connection of the nail. The implants are made from the Titanium alloy (Ti6Al4V) according to ASTM F 136 / ISO 5832-3, with a Type II anodization according to AMS 2488. There are Instruments which are specific to the implantation of the SACRONAIL device. These include, but are not limited to, the Guide Frame, the Guide Bracket, the Fixation Bracket, various Instrument Guides, various dilators and drills, screwdrivers as well as the specific tools for revision of the device. SACRONAIL SIGNUS MEDIZINTECHNIK GMBH
37 04047844039915 Pelvic nail PBX080190 DescriptionThe SACRONAIL system provides a sustained, stable restoration of dors DescriptionThe SACRONAIL system provides a sustained, stable restoration of dorsal pelvic fractures and sacral fractures through its intraosseous location and its direct, bi-iliac symmetric anchorage. The implant consists of a nail of various lengths from135mm to 194mm with a constant diameter of 8mm and 2 locking screws in different lengths. This variation ensures adaptation to the respective anatomy of the patient. The intersections of the screw axes to the implant axis have a distance of 15mm to the respective end face of the nail. This ensures a solid support on the lateral cortex of the Ilia. The angle of the screw axes to the implant axis corresponds to the anatomical conditions and is 70°. The locking screw ensures a stable connection of the components. The tips of the locking screws are rounded to facilitate insertion into the nail while the dorsal ends of locking screws are a hexagon. The caps serve to close the instrument connection of the nail. The implants are made from the Titanium alloy (Ti6Al4V) according to ASTM F 136 / ISO 5832-3, with a Type II anodization according to AMS 2488. There are Instruments which are specific to the implantation of the SACRONAIL device. These include, but are not limited to, the Guide Frame, the Guide Bracket, the Fixation Bracket, various Instrument Guides, various dilators and drills, screwdrivers as well as the specific tools for revision of the device. SACRONAIL SIGNUS MEDIZINTECHNIK GMBH
38 04047844039908 Pelvic nail PBX080186 DescriptionThe SACRONAIL system provides a sustained, stable restoration of dors DescriptionThe SACRONAIL system provides a sustained, stable restoration of dorsal pelvic fractures and sacral fractures through its intraosseous location and its direct, bi-iliac symmetric anchorage. The implant consists of a nail of various lengths from135mm to 194mm with a constant diameter of 8mm and 2 locking screws in different lengths. This variation ensures adaptation to the respective anatomy of the patient. The intersections of the screw axes to the implant axis have a distance of 15mm to the respective end face of the nail. This ensures a solid support on the lateral cortex of the Ilia. The angle of the screw axes to the implant axis corresponds to the anatomical conditions and is 70°. The locking screw ensures a stable connection of the components. The tips of the locking screws are rounded to facilitate insertion into the nail while the dorsal ends of locking screws are a hexagon. The caps serve to close the instrument connection of the nail. The implants are made from the Titanium alloy (Ti6Al4V) according to ASTM F 136 / ISO 5832-3, with a Type II anodization according to AMS 2488. There are Instruments which are specific to the implantation of the SACRONAIL device. These include, but are not limited to, the Guide Frame, the Guide Bracket, the Fixation Bracket, various Instrument Guides, various dilators and drills, screwdrivers as well as the specific tools for revision of the device. SACRONAIL SIGNUS MEDIZINTECHNIK GMBH
39 04047844039892 Pelvic nail PBX080182 DescriptionThe SACRONAIL system provides a sustained, stable restoration of dors DescriptionThe SACRONAIL system provides a sustained, stable restoration of dorsal pelvic fractures and sacral fractures through its intraosseous location and its direct, bi-iliac symmetric anchorage. The implant consists of a nail of various lengths from135mm to 194mm with a constant diameter of 8mm and 2 locking screws in different lengths. This variation ensures adaptation to the respective anatomy of the patient. The intersections of the screw axes to the implant axis have a distance of 15mm to the respective end face of the nail. This ensures a solid support on the lateral cortex of the Ilia. The angle of the screw axes to the implant axis corresponds to the anatomical conditions and is 70°. The locking screw ensures a stable connection of the components. The tips of the locking screws are rounded to facilitate insertion into the nail while the dorsal ends of locking screws are a hexagon. The caps serve to close the instrument connection of the nail. The implants are made from the Titanium alloy (Ti6Al4V) according to ASTM F 136 / ISO 5832-3, with a Type II anodization according to AMS 2488. There are Instruments which are specific to the implantation of the SACRONAIL device. These include, but are not limited to, the Guide Frame, the Guide Bracket, the Fixation Bracket, various Instrument Guides, various dilators and drills, screwdrivers as well as the specific tools for revision of the device. SACRONAIL SIGNUS MEDIZINTECHNIK GMBH
40 04047844039885 Pelvic nail PBX080178 DescriptionThe SACRONAIL system provides a sustained, stable restoration of dors DescriptionThe SACRONAIL system provides a sustained, stable restoration of dorsal pelvic fractures and sacral fractures through its intraosseous location and its direct, bi-iliac symmetric anchorage. The implant consists of a nail of various lengths from135mm to 194mm with a constant diameter of 8mm and 2 locking screws in different lengths. This variation ensures adaptation to the respective anatomy of the patient. The intersections of the screw axes to the implant axis have a distance of 15mm to the respective end face of the nail. This ensures a solid support on the lateral cortex of the Ilia. The angle of the screw axes to the implant axis corresponds to the anatomical conditions and is 70°. The locking screw ensures a stable connection of the components. The tips of the locking screws are rounded to facilitate insertion into the nail while the dorsal ends of locking screws are a hexagon. The caps serve to close the instrument connection of the nail. The implants are made from the Titanium alloy (Ti6Al4V) according to ASTM F 136 / ISO 5832-3, with a Type II anodization according to AMS 2488. There are Instruments which are specific to the implantation of the SACRONAIL device. These include, but are not limited to, the Guide Frame, the Guide Bracket, the Fixation Bracket, various Instrument Guides, various dilators and drills, screwdrivers as well as the specific tools for revision of the device. SACRONAIL SIGNUS MEDIZINTECHNIK GMBH
41 04047844039878 Pelvic nail PBX080174 DescriptionThe SACRONAIL system provides a sustained, stable restoration of dors DescriptionThe SACRONAIL system provides a sustained, stable restoration of dorsal pelvic fractures and sacral fractures through its intraosseous location and its direct, bi-iliac symmetric anchorage. The implant consists of a nail of various lengths from135mm to 194mm with a constant diameter of 8mm and 2 locking screws in different lengths. This variation ensures adaptation to the respective anatomy of the patient. The intersections of the screw axes to the implant axis have a distance of 15mm to the respective end face of the nail. This ensures a solid support on the lateral cortex of the Ilia. The angle of the screw axes to the implant axis corresponds to the anatomical conditions and is 70°. The locking screw ensures a stable connection of the components. The tips of the locking screws are rounded to facilitate insertion into the nail while the dorsal ends of locking screws are a hexagon. The caps serve to close the instrument connection of the nail. The implants are made from the Titanium alloy (Ti6Al4V) according to ASTM F 136 / ISO 5832-3, with a Type II anodization according to AMS 2488. There are Instruments which are specific to the implantation of the SACRONAIL device. These include, but are not limited to, the Guide Frame, the Guide Bracket, the Fixation Bracket, various Instrument Guides, various dilators and drills, screwdrivers as well as the specific tools for revision of the device. SACRONAIL SIGNUS MEDIZINTECHNIK GMBH
42 04047844039861 Pelvic nail PBX080170 DescriptionThe SACRONAIL system provides a sustained, stable restoration of dors DescriptionThe SACRONAIL system provides a sustained, stable restoration of dorsal pelvic fractures and sacral fractures through its intraosseous location and its direct, bi-iliac symmetric anchorage. The implant consists of a nail of various lengths from135mm to 194mm with a constant diameter of 8mm and 2 locking screws in different lengths. This variation ensures adaptation to the respective anatomy of the patient. The intersections of the screw axes to the implant axis have a distance of 15mm to the respective end face of the nail. This ensures a solid support on the lateral cortex of the Ilia. The angle of the screw axes to the implant axis corresponds to the anatomical conditions and is 70°. The locking screw ensures a stable connection of the components. The tips of the locking screws are rounded to facilitate insertion into the nail while the dorsal ends of locking screws are a hexagon. The caps serve to close the instrument connection of the nail. The implants are made from the Titanium alloy (Ti6Al4V) according to ASTM F 136 / ISO 5832-3, with a Type II anodization according to AMS 2488. There are Instruments which are specific to the implantation of the SACRONAIL device. These include, but are not limited to, the Guide Frame, the Guide Bracket, the Fixation Bracket, various Instrument Guides, various dilators and drills, screwdrivers as well as the specific tools for revision of the device. SACRONAIL SIGNUS MEDIZINTECHNIK GMBH
43 04047844039854 Pelvic nail PBX080166 DescriptionThe SACRONAIL system provides a sustained, stable restoration of dors DescriptionThe SACRONAIL system provides a sustained, stable restoration of dorsal pelvic fractures and sacral fractures through its intraosseous location and its direct, bi-iliac symmetric anchorage. The implant consists of a nail of various lengths from135mm to 194mm with a constant diameter of 8mm and 2 locking screws in different lengths. This variation ensures adaptation to the respective anatomy of the patient. The intersections of the screw axes to the implant axis have a distance of 15mm to the respective end face of the nail. This ensures a solid support on the lateral cortex of the Ilia. The angle of the screw axes to the implant axis corresponds to the anatomical conditions and is 70°. The locking screw ensures a stable connection of the components. The tips of the locking screws are rounded to facilitate insertion into the nail while the dorsal ends of locking screws are a hexagon. The caps serve to close the instrument connection of the nail. The implants are made from the Titanium alloy (Ti6Al4V) according to ASTM F 136 / ISO 5832-3, with a Type II anodization according to AMS 2488. There are Instruments which are specific to the implantation of the SACRONAIL device. These include, but are not limited to, the Guide Frame, the Guide Bracket, the Fixation Bracket, various Instrument Guides, various dilators and drills, screwdrivers as well as the specific tools for revision of the device. SACRONAIL SIGNUS MEDIZINTECHNIK GMBH
44 04047844039847 Pelvic nail PBX080163 DescriptionThe SACRONAIL system provides a sustained, stable restoration of dors DescriptionThe SACRONAIL system provides a sustained, stable restoration of dorsal pelvic fractures and sacral fractures through its intraosseous location and its direct, bi-iliac symmetric anchorage. The implant consists of a nail of various lengths from135mm to 194mm with a constant diameter of 8mm and 2 locking screws in different lengths. This variation ensures adaptation to the respective anatomy of the patient. The intersections of the screw axes to the implant axis have a distance of 15mm to the respective end face of the nail. This ensures a solid support on the lateral cortex of the Ilia. The angle of the screw axes to the implant axis corresponds to the anatomical conditions and is 70°. The locking screw ensures a stable connection of the components. The tips of the locking screws are rounded to facilitate insertion into the nail while the dorsal ends of locking screws are a hexagon. The caps serve to close the instrument connection of the nail. The implants are made from the Titanium alloy (Ti6Al4V) according to ASTM F 136 / ISO 5832-3, with a Type II anodization according to AMS 2488. There are Instruments which are specific to the implantation of the SACRONAIL device. These include, but are not limited to, the Guide Frame, the Guide Bracket, the Fixation Bracket, various Instrument Guides, various dilators and drills, screwdrivers as well as the specific tools for revision of the device. SACRONAIL SIGNUS MEDIZINTECHNIK GMBH
45 04047844039830 Pelvic nail PBX080160 DescriptionThe SACRONAIL system provides a sustained, stable restoration of dors DescriptionThe SACRONAIL system provides a sustained, stable restoration of dorsal pelvic fractures and sacral fractures through its intraosseous location and its direct, bi-iliac symmetric anchorage. The implant consists of a nail of various lengths from135mm to 194mm with a constant diameter of 8mm and 2 locking screws in different lengths. This variation ensures adaptation to the respective anatomy of the patient. The intersections of the screw axes to the implant axis have a distance of 15mm to the respective end face of the nail. This ensures a solid support on the lateral cortex of the Ilia. The angle of the screw axes to the implant axis corresponds to the anatomical conditions and is 70°. The locking screw ensures a stable connection of the components. The tips of the locking screws are rounded to facilitate insertion into the nail while the dorsal ends of locking screws are a hexagon. The caps serve to close the instrument connection of the nail. The implants are made from the Titanium alloy (Ti6Al4V) according to ASTM F 136 / ISO 5832-3, with a Type II anodization according to AMS 2488. There are Instruments which are specific to the implantation of the SACRONAIL device. These include, but are not limited to, the Guide Frame, the Guide Bracket, the Fixation Bracket, various Instrument Guides, various dilators and drills, screwdrivers as well as the specific tools for revision of the device. SACRONAIL SIGNUS MEDIZINTECHNIK GMBH
46 04047844039823 Pelvic nail PBX080157 DescriptionThe SACRONAIL system provides a sustained, stable restoration of dors DescriptionThe SACRONAIL system provides a sustained, stable restoration of dorsal pelvic fractures and sacral fractures through its intraosseous location and its direct, bi-iliac symmetric anchorage. The implant consists of a nail of various lengths from135mm to 194mm with a constant diameter of 8mm and 2 locking screws in different lengths. This variation ensures adaptation to the respective anatomy of the patient. The intersections of the screw axes to the implant axis have a distance of 15mm to the respective end face of the nail. This ensures a solid support on the lateral cortex of the Ilia. The angle of the screw axes to the implant axis corresponds to the anatomical conditions and is 70°. The locking screw ensures a stable connection of the components. The tips of the locking screws are rounded to facilitate insertion into the nail while the dorsal ends of locking screws are a hexagon. The caps serve to close the instrument connection of the nail. The implants are made from the Titanium alloy (Ti6Al4V) according to ASTM F 136 / ISO 5832-3, with a Type II anodization according to AMS 2488. There are Instruments which are specific to the implantation of the SACRONAIL device. These include, but are not limited to, the Guide Frame, the Guide Bracket, the Fixation Bracket, various Instrument Guides, various dilators and drills, screwdrivers as well as the specific tools for revision of the device. SACRONAIL SIGNUS MEDIZINTECHNIK GMBH
47 04047844039816 Pelvic nail PBX080154 DescriptionThe SACRONAIL system provides a sustained, stable restoration of dors DescriptionThe SACRONAIL system provides a sustained, stable restoration of dorsal pelvic fractures and sacral fractures through its intraosseous location and its direct, bi-iliac symmetric anchorage. The implant consists of a nail of various lengths from135mm to 194mm with a constant diameter of 8mm and 2 locking screws in different lengths. This variation ensures adaptation to the respective anatomy of the patient. The intersections of the screw axes to the implant axis have a distance of 15mm to the respective end face of the nail. This ensures a solid support on the lateral cortex of the Ilia. The angle of the screw axes to the implant axis corresponds to the anatomical conditions and is 70°. The locking screw ensures a stable connection of the components. The tips of the locking screws are rounded to facilitate insertion into the nail while the dorsal ends of locking screws are a hexagon. The caps serve to close the instrument connection of the nail. The implants are made from the Titanium alloy (Ti6Al4V) according to ASTM F 136 / ISO 5832-3, with a Type II anodization according to AMS 2488. There are Instruments which are specific to the implantation of the SACRONAIL device. These include, but are not limited to, the Guide Frame, the Guide Bracket, the Fixation Bracket, various Instrument Guides, various dilators and drills, screwdrivers as well as the specific tools for revision of the device. SACRONAIL SIGNUS MEDIZINTECHNIK GMBH
48 04047844039809 Pelvic nail PBX080151 DescriptionThe SACRONAIL system provides a sustained, stable restoration of dors DescriptionThe SACRONAIL system provides a sustained, stable restoration of dorsal pelvic fractures and sacral fractures through its intraosseous location and its direct, bi-iliac symmetric anchorage. The implant consists of a nail of various lengths from135mm to 194mm with a constant diameter of 8mm and 2 locking screws in different lengths. This variation ensures adaptation to the respective anatomy of the patient. The intersections of the screw axes to the implant axis have a distance of 15mm to the respective end face of the nail. This ensures a solid support on the lateral cortex of the Ilia. The angle of the screw axes to the implant axis corresponds to the anatomical conditions and is 70°. The locking screw ensures a stable connection of the components. The tips of the locking screws are rounded to facilitate insertion into the nail while the dorsal ends of locking screws are a hexagon. The caps serve to close the instrument connection of the nail. The implants are made from the Titanium alloy (Ti6Al4V) according to ASTM F 136 / ISO 5832-3, with a Type II anodization according to AMS 2488. There are Instruments which are specific to the implantation of the SACRONAIL device. These include, but are not limited to, the Guide Frame, the Guide Bracket, the Fixation Bracket, various Instrument Guides, various dilators and drills, screwdrivers as well as the specific tools for revision of the device. SACRONAIL SIGNUS MEDIZINTECHNIK GMBH
49 04047844039793 Pelvic nail PBX080148 DescriptionThe SACRONAIL system provides a sustained, stable restoration of dors DescriptionThe SACRONAIL system provides a sustained, stable restoration of dorsal pelvic fractures and sacral fractures through its intraosseous location and its direct, bi-iliac symmetric anchorage. The implant consists of a nail of various lengths from135mm to 194mm with a constant diameter of 8mm and 2 locking screws in different lengths. This variation ensures adaptation to the respective anatomy of the patient. The intersections of the screw axes to the implant axis have a distance of 15mm to the respective end face of the nail. This ensures a solid support on the lateral cortex of the Ilia. The angle of the screw axes to the implant axis corresponds to the anatomical conditions and is 70°. The locking screw ensures a stable connection of the components. The tips of the locking screws are rounded to facilitate insertion into the nail while the dorsal ends of locking screws are a hexagon. The caps serve to close the instrument connection of the nail. The implants are made from the Titanium alloy (Ti6Al4V) according to ASTM F 136 / ISO 5832-3, with a Type II anodization according to AMS 2488. There are Instruments which are specific to the implantation of the SACRONAIL device. These include, but are not limited to, the Guide Frame, the Guide Bracket, the Fixation Bracket, various Instrument Guides, various dilators and drills, screwdrivers as well as the specific tools for revision of the device. SACRONAIL SIGNUS MEDIZINTECHNIK GMBH
50 04047844039786 Pelvic nail PBX080145 DescriptionThe SACRONAIL system provides a sustained, stable restoration of dors DescriptionThe SACRONAIL system provides a sustained, stable restoration of dorsal pelvic fractures and sacral fractures through its intraosseous location and its direct, bi-iliac symmetric anchorage. The implant consists of a nail of various lengths from135mm to 194mm with a constant diameter of 8mm and 2 locking screws in different lengths. This variation ensures adaptation to the respective anatomy of the patient. The intersections of the screw axes to the implant axis have a distance of 15mm to the respective end face of the nail. This ensures a solid support on the lateral cortex of the Ilia. The angle of the screw axes to the implant axis corresponds to the anatomical conditions and is 70°. The locking screw ensures a stable connection of the components. The tips of the locking screws are rounded to facilitate insertion into the nail while the dorsal ends of locking screws are a hexagon. The caps serve to close the instrument connection of the nail. The implants are made from the Titanium alloy (Ti6Al4V) according to ASTM F 136 / ISO 5832-3, with a Type II anodization according to AMS 2488. There are Instruments which are specific to the implantation of the SACRONAIL device. These include, but are not limited to, the Guide Frame, the Guide Bracket, the Fixation Bracket, various Instrument Guides, various dilators and drills, screwdrivers as well as the specific tools for revision of the device. SACRONAIL SIGNUS MEDIZINTECHNIK GMBH