No | Primary DI | Version or Model | Catalog Number | Device Description | Product Code | Product Code Name | Device Class | Brand Name |
---|---|---|---|---|---|---|---|---|
1 | 90814008025315 | PLE-015-S | PLIF Encoded 10x22 15mm 0 Degrees | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | nvp | |
2 | 90814008024974 | PLE-010-L | PLIF Encoded 10x30 10mm 0 Degree | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | nvp | |
3 | 90814008024967 | PLE-009-L | PLIF Encoded 10x30 9mm 0 Degree | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | nvp | |
4 | 90814008024950 | PLE-008-L | PLIF Encoded 10x30 8mm 0 Degree | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | nvp | |
5 | 90814008024943 | PLE-007-L | PLIF Encoded 10x30 7mm 0 Degree | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | nvp | |
6 | 90814008024936 | PLE-006-L | PLIF Encoded 10x30 6mm 0 Degree | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | nvp | |
7 | 90814008024929 | PLE-615-M | PLIF Encoded 10x26 15mm 6 Degree | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | nvp | |
8 | 90814008024912 | PLE-614-M | PLIF Encoded 10x26 14mm 6 Degree | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | nvp | |
9 | 90814008024905 | PLE-613-M | PLIF Encoded 10x26 13mm 6 Degree | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | nvp | |
10 | 90814008024899 | PLE-612-M | PLIF Encoded 10x26 12mm 6 Degree | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | nvp | |
11 | 90814008024882 | PLE-611-M | PLIF Encoded 10x26 11mm 6 Degree | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | nvp | |
12 | 90814008024875 | PLE-610-M | PLIF Encoded 10x26 10mm 6 Degree | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | nvp | |
13 | 90814008024868 | PLE-609-M | PLIF Encoded 10x26 9mm 6 Degree | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | nvp | |
14 | 90814008024851 | PLE-608-M | PLIF Encoded 10x26 8mm 6 Degree | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | nvp | |
15 | 90814008024844 | PLE-607-M | PLIF Encoded 10x26 7mm 6 Degree | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | nvp | |
16 | 90814008024837 | PLE-015-M | PLIF Encoded 10x26 15mm 0 Degrees | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | nvp | |
17 | 90814008024820 | PLE-014-M | PLIF Encoded 10x26 14mm 0 Degrees | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | nvp | |
18 | 90814008024813 | PLE-013-M | PLIF Encoded 10x26 13mm 0 Degrees | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | nvp | |
19 | 90814008024806 | PLE-012-M | PLIF Encoded 10x26 12mm 0 Degrees | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | nvp | |
20 | 90814008024790 | PLE-011-M | PLIF Encoded 10x26 11mm 0 Degrees | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | nvp | |
21 | 90814008024783 | PLE-010-M | PLIF Encoded 10x26 10mm 0 Degrees | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | nvp | |
22 | 90814008024776 | PLE-009-M | PLIF Encoded 10x26 9mm 0 Degrees | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | nvp | |
23 | 90814008024769 | PLE-008-M | PLIF Encoded 10x26 8mm 0 Degrees | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | nvp | |
24 | 90814008024752 | PLE-007-M | PLIF Encoded 10x26 7mm 0 Degrees | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | nvp | |
25 | 90814008024745 | PLE-006-M | PLIF Encoded 10x26 6mm 0 Degrees | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | nvp | |
26 | 90814008024738 | PLE-014-S | PLIF Encoded 10x22 14mm 0 Degrees | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | nvp | |
27 | 90814008024721 | PLE-013-S | PLIF Encoded 10x22 13mm 0 Degrees | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | nvp | |
28 | 90814008024714 | PLE-012-S | PLIF Encoded 10x22 12mm 0 Degrees | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | nvp | |
29 | 90814008024707 | PLE-011-S | PLIF Encoded 10x22 11mm 0 Degrees | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | nvp | |
30 | 90814008024691 | PLE-010-S | PLIF Encoded 10x22 10mm 0 Degrees | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | nvp | |
31 | 90814008024684 | PLE-009-S | PLIF Encoded 10x22 9mm 0 Degrees | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | nvp | |
32 | 90814008024677 | PLE-008-S | PLIF Encoded 10x22 8mm 0 Degrees | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | nvp | |
33 | 90814008024660 | PLE-007-S | PLIF Encoded 10x22 7mm 0 Degrees | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | nvp | |
34 | 90814008024653 | PLE-006-S | PLIF Encoded 10x22 6mm 0 Degrees | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | nvp | |
35 | 00810005664905 | PD-1000C-750 | Caddy 7.5 Screws. The FOCUS Pedicle Screw System is intended for use in the non Caddy 7.5 Screws. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion. | LRP | Tray, Surgical | 1 | Focus | |
36 | 00810005664899 | PD-1000C-650 | Caddy 6.5 Screws. The FOCUS Pedicle Screw System is intended for use in the non Caddy 6.5 Screws. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion. | LRP | Tray, Surgical | 1 | Focus | |
37 | 00810005662253 | PD-1000C-475 | Caddy 4.75 Screws. The FOCUS Pedicle Screw System is intended for use in the no Caddy 4.75 Screws. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion. | LRP | Tray, Surgical | 1 | Focus | |
38 | 00810005662246 | PD-1000C-SS | Caddy Set Screws. The FOCUS Pedicle Screw System is intended for use in the non Caddy Set Screws. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion. | LRP | Tray, Surgical | 1 | Focus | |
39 | 00810005662239 | PD-1000C-CC | Caddy CrossLinks. The FOCUS Pedicle Screw System is intended for use in the non Caddy CrossLinks. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion. | LRP | Tray, Surgical | 1 | Focus | |
40 | 00810005662222 | PD-1000C-LR | Caddy Lordotic Rods. The FOCUS Pedicle Screw System is intended for use in the Caddy Lordotic Rods. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion. | LRP | Tray, Surgical | 1 | Focus | |
41 | 00810005662215 | PD-1000C-SR | Caddy Straight Rods. The FOCUS Pedicle Screw System is intended for use in the Caddy Straight Rods. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion. | LRP | Tray, Surgical | 1 | Focus | |
42 | 90814008024981 | PLE-011-L | PLIF Encoded 10x30 11mm 0 Degree | MAX | Intervertebral Fusion Device With Bone Graft, Lumbar | 2 | nvp | |
43 | 00810005662208 | PD-1000C-106 | Pedicle Screw Case 4 INSERT 4 Instruments. The FOCUS Pedicle Screw System is in Pedicle Screw Case 4 INSERT 4 Instruments. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion. | LRP | Tray, Surgical | 1 | Focus | |
44 | 00810005662192 | PD-1000C-105 | Pedicle Screw Case 4 INSERT 3 Instruments. The FOCUS Pedicle Screw System is in Pedicle Screw Case 4 INSERT 3 Instruments. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion. | LRP | Tray, Surgical | 1 | Focus | |
45 | 00810005662185 | PD-1000C-104 | Pedicle Screw Case 3 INSERT 2 Instruments. The FOCUS Pedicle Screw System is in Pedicle Screw Case 3 INSERT 2 Instruments. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion. | LRP | Tray, Surgical | 1 | Focus | |
46 | 00810005662178 | PD-1000C-103 | Pedicle Screw Case 3 INSERT 1 Instruments. The FOCUS Pedicle Screw System is in Pedicle Screw Case 3 INSERT 1 Instruments. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion. | LRP | Tray, Surgical | 1 | Focus | |
47 | 00810005662161 | PD-1000C-102 | Pedicle Screw Case, Instruments. The FOCUS Pedicle Screw System is intended for Pedicle Screw Case, Instruments. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion. | LRP | Tray, Surgical | 1 | Focus | |
48 | 00810005662154 | PD-1000C-204 | Pedicle Screw Case 2 INSERT 3. The FOCUS Pedicle Screw System is intended for u Pedicle Screw Case 2 INSERT 3. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion. | LRP | Tray, Surgical | 1 | Focus | |
49 | 00810005662147 | PD-1000C-211 | Pedicle Screw Case 2 Base, Implants. The FOCUS Pedicle Screw System is intended Pedicle Screw Case 2 Base, Implants. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion. | LRP | Tray, Surgical | 1 | Focus | |
50 | 00810005662130 | PD-1000C-202 | Pedicle Screw Case 1 INSERT 2. The FOCUS Pedicle Screw System is intended for u Pedicle Screw Case 1 INSERT 2. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion. | LRP | Tray, Surgical | 1 | Focus |
No | Primary DI | Version or Model | Catalog Number | Device Description | Brand Name | Organization Name |
---|---|---|---|---|---|---|
1 | 04047844014059 | Cervical cage, angled | WK101212 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 5° | SIGNUS MEDIZINTECHNIK GMBH |
2 | 04047844014042 | Cervical cage, angled | WK091212 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 5° | SIGNUS MEDIZINTECHNIK GMBH |
3 | 04047844010617 | Cervical cage | NB121317 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | NUBIC | SIGNUS MEDIZINTECHNIK GMBH |
4 | 04047844010600 | Cervical cage | NB111317 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | NUBIC | SIGNUS MEDIZINTECHNIK GMBH |
5 | 04047844010594 | Cervical cage | NB101317 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | NUBIC | SIGNUS MEDIZINTECHNIK GMBH |
6 | 04047844010587 | Cervical cage | NB091317 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | NUBIC | SIGNUS MEDIZINTECHNIK GMBH |
7 | 04047844010570 | Cervical cage | NB081317 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | NUBIC | SIGNUS MEDIZINTECHNIK GMBH |
8 | 04047844010563 | Cervical cage | NB071317 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | NUBIC | SIGNUS MEDIZINTECHNIK GMBH |
9 | 04047844010556 | Cervical cage | NB061317 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | NUBIC | SIGNUS MEDIZINTECHNIK GMBH |
10 | 04047844010549 | Cervical cage | NB051317 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | NUBIC | SIGNUS MEDIZINTECHNIK GMBH |
11 | 04047844010532 | Cervical cage | NB041317 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | NUBIC | SIGNUS MEDIZINTECHNIK GMBH |
12 | 04047844009192 | Cervical cage | NB111314 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | NUBIC | SIGNUS MEDIZINTECHNIK GMBH |
13 | 04047844009178 | Cervical cage with strut | N111314 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | NUBIC | SIGNUS MEDIZINTECHNIK GMBH |
14 | 04047844009161 | Cervical cage with strut | N101314 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | NUBIC | SIGNUS MEDIZINTECHNIK GMBH |
15 | 04047844009154 | Cervical cage with strut | N091314 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | NUBIC | SIGNUS MEDIZINTECHNIK GMBH |
16 | 04047844002414 | Connection screw | ATM309 | The ATHLET VBR System is a lordotic, modular vertebral body replacement system. The ATHLET VBR System is a lordotic, modular vertebral body replacement system. Caudal and cranial components are offered in a variety of heights and are assembled to create a device construct. An intermediate component is also available and is used between one caudal and one cranial component. The device construct comprises a central cannula for bone graft and lateral fenestrations for bony in-growth. | ATHLET | SIGNUS MEDIZINTECHNIK GMBH |
17 | 04047844002056 | Cervical cage with strut | N081314 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | NUBIC | SIGNUS MEDIZINTECHNIK GMBH |
18 | 04047844002049 | Cervical cage with strut | N071314 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | NUBIC | SIGNUS MEDIZINTECHNIK GMBH |
19 | 04047844002032 | Cervical cage with strut | N061314 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | NUBIC | SIGNUS MEDIZINTECHNIK GMBH |
20 | 04047844002025 | Cervical cage with strut | N051314 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | NUBIC | SIGNUS MEDIZINTECHNIK GMBH |
21 | 04047844002018 | Cervical cage with strut | N041314 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | NUBIC | SIGNUS MEDIZINTECHNIK GMBH |
22 | 04047844000694 | Cervical cage, angled | WK081414 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 5° | SIGNUS MEDIZINTECHNIK GMBH |
23 | 04047844000687 | Cervical cage, angled | WK081214 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 5° | SIGNUS MEDIZINTECHNIK GMBH |
24 | 04047844000670 | Cervical cage, angled | WK081212 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 5° | SIGNUS MEDIZINTECHNIK GMBH |
25 | 04047844000663 | Cervical cage, angled | WK071414 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 5° | SIGNUS MEDIZINTECHNIK GMBH |
26 | 04047844000656 | Cervical cage, angled | WK071212 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 5° | SIGNUS MEDIZINTECHNIK GMBH |
27 | 04047844000649 | Cervical cage, angled | WK061414 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 5° | SIGNUS MEDIZINTECHNIK GMBH |
28 | 04047844000632 | Cervical cage, angled | WK061212 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 5° | SIGNUS MEDIZINTECHNIK GMBH |
29 | 04047844000625 | Cervical cage, angled | WK051414 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 5° | SIGNUS MEDIZINTECHNIK GMBH |
30 | 04047844000618 | Cervical cage, angled | WK051212 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 5° | SIGNUS MEDIZINTECHNIK GMBH |
31 | 04047844000601 | Cervical cage, angled | WK041414 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 5° | SIGNUS MEDIZINTECHNIK GMBH |
32 | 04047844000595 | Cervical cage, angled | WK041212 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 5° | SIGNUS MEDIZINTECHNIK GMBH |
33 | 04047844000588 | Cervical cage, straight | PK101214 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 0° | SIGNUS MEDIZINTECHNIK GMBH |
34 | 04047844000571 | Cervical cage, straight | PK101212 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 0° | SIGNUS MEDIZINTECHNIK GMBH |
35 | 04047844000564 | Cervical cage, straight | PK091214 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 0° | SIGNUS MEDIZINTECHNIK GMBH |
36 | 04047844000557 | Cervical cage, straight | PK091212 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 0° | SIGNUS MEDIZINTECHNIK GMBH |
37 | 04047844000540 | Cervical cage, straight | PK081414 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 0° | SIGNUS MEDIZINTECHNIK GMBH |
38 | 04047844000533 | Cervical cage, straight | PK081216 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 0° | SIGNUS MEDIZINTECHNIK GMBH |
39 | 04047844000526 | Cervical cage, straight | PK081212 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 0° | SIGNUS MEDIZINTECHNIK GMBH |
40 | 04047844000519 | Cervical cage, straight | PK071414 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 0° | SIGNUS MEDIZINTECHNIK GMBH |
41 | 04047844000502 | Cervical cage, straight | PK071216 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 0° | SIGNUS MEDIZINTECHNIK GMBH |
42 | 04047844000496 | Cervical cage, straight | PK071212 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 0° | SIGNUS MEDIZINTECHNIK GMBH |
43 | 04047844000489 | Cervical cage, straight | PK061414 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 0° | SIGNUS MEDIZINTECHNIK GMBH |
44 | 04047844000472 | Cervical cage, straight | PK061216 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 0° | SIGNUS MEDIZINTECHNIK GMBH |
45 | 04047844000465 | Cervical cage, straight | PK061212 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 0° | SIGNUS MEDIZINTECHNIK GMBH |
46 | 04047844000458 | Cervical cage, straight | PK051414 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 0° | SIGNUS MEDIZINTECHNIK GMBH |
47 | 04047844000441 | Cervical cage, straight | PK051216 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 0° | SIGNUS MEDIZINTECHNIK GMBH |
48 | 04047844000434 | Cervical cage, straight | PK051212 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 0° | SIGNUS MEDIZINTECHNIK GMBH |
49 | 04047844000427 | Cervical cage, straight | PK041414 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 0° | SIGNUS MEDIZINTECHNIK GMBH |
50 | 04047844000410 | Cervical cage, straight | PK041216 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 0° | SIGNUS MEDIZINTECHNIK GMBH |