Patient Interface Kit for VICTUS™ Femtosecond Laser Platform (software version 2
Patient Interface Kit for VICTUS™ Femtosecond Laser Platform (software version 2.7 and higher).Kit consists of Patient Interface and Suction Clip 125.
Patient Interface Kit for VICTUS™ Femtosecond Laser Platform (software version 2
Patient Interface Kit for VICTUS™ Femtosecond Laser Platform (software version 2.7 and higher).Kit consists of Patient Interface 125 and Suction Clip 125.
The VisuMax laser keratome is a femtosecond laser. It generates a beam of ultra-
The VisuMax laser keratome is a femtosecond laser. It generates a beam of ultra-short laser pulses whichare guided through the aperture in the treatment objective .The optical system focuses the laser beam into the corneal tissue.The VisuMax femtosecond laser is indicated for use in ophthalmic surgery for the creation of corneal incisions in patients undergoing the following treatments:• In the creation of a corneal flap in patients undergoing LASIK surgery or other treatment requiring initial lamellar resection of the cornea• In patients undergoing surgery or other treatment requiring initial lamellar resection of the cornea• In the creation of a lamellar cut/resection of the cornea for lamellar keratoplasty• In the creation of a cut/incision for penetrating keratoplasty and corneal harvesting• Surgery or other treatment requiring initial lamellar resection of the cornea to create tunnels for placement of corneal ring segments.Additionally under class III: The VisuMax Femtosecond Laser is indicated for use in small incisionlenticule extraction (SMILE) for the reduction or elimination ofmyopia with or without astigmatism• for spherical refractive error (in minus cylinder format) from -1.00 diopters through -10.00 diopters,• for cylinder from -0.75 diopters through -3.00 diopters,• when refraction spherical equivalent is no greater in magnitude than 10.00 diopters,in patients 22 years of age or older with documentation of stable manifest refraction over the past year as demonstrated by a change in sphere and cylinder of ≤ 0.50 D in magnitude.
VISULAS green is intended for use in photocoagulation of tissues in the posterio
VISULAS green is intended for use in photocoagulation of tissues in the posterior and anterior segments of the eye including trabeculoplasty and iridotomy.The DI number characterizes the laser console which has a dual fiber port. The laser console with dual fiber port forms part of both models, VISULAS green classic and VISULAS green comfort.
VISULAS green is intended for use in photocoagulation of tissues in the posterio
VISULAS green is intended for use in photocoagulation of tissues in the posterior and anterior segments of the eye including trabeculoplasty and iridotomy.The DI number characterizes the laser console which has one single fiber port. The laser console with single fiber port forms part of both models, VISULAS green classic and VISULAS green comfort.
VISULAS green is intended for use in photocoagulation of tissues in the posterio
VISULAS green is intended for use in photocoagulation of tissues in the posterior and anterior segments of the eye including trabeculoplasty and iridotomy.The DI number characterizes the laser slit lamp LSL green comfort. This laser slit lamp forms part of the model VISULAS green comfort.
VISULAS green is intended for use in photocoagulation of tissues in the posterio
VISULAS green is intended for use in photocoagulation of tissues in the posterior and anterior segments of the eye including trabeculoplasty and iridotomy.The DI number characterizes the laser slit lamp LSL green classic. This laser slit lamp forms part of the model VISULAS green classic.
The VISULAS Trion Laser System is intended for use in single-spot laser photocoa
The VISULAS Trion Laser System is intended for use in single-spot laser photocoagulation of ocular tissues for the treatment of diseases of the eye, such as:* Photocoagulation of the retina* Trabeculoplasty for treatment of glaucoma* Iridotomy for treatment of glaucoma.The VISULAS Trion Laser System with the VITE option is intended for use in multispot retinal, panretinal, focal and grid photocoagulation of ocular tissues in the treatment of diseases of the eye including:* Proliferative and nonproliferative diabetic retinopathy* Macular edema* Branch and central retinal vein occlusion* Lattice degeneration* Retinal tears and detachments* Choroidal neovascularization associated with wet age-related macular degeneration.
The laser (577 nm Fiber Techology Laser SingleSpot, MultiSpot and Subliminal mod
The laser (577 nm Fiber Techology Laser SingleSpot, MultiSpot and Subliminal mode and Slit Lamp Zeiss mode) is a photocoagulator device intended for the treatment of retinal diseases.
The Vitra 810 is a laser system which emits a treatment beam at 810 nm and is in
The Vitra 810 is a laser system which emits a treatment beam at 810 nm and is intended for use in photocoagulation of ocular tissues in the treatment of diseases of the eye. The laser is used to treat the retinal diseases and glaucoma.
The laser (577 nm Fiber Techology Laser SingleSpot, MultiSpot and Subliminal mod
The laser (577 nm Fiber Techology Laser SingleSpot, MultiSpot and Subliminal mode and Slit Lamp Haag Streit mode) is a photocoagulator device intended for the treatment of retinal diseases.