Other products from "VITREQ B.V."
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 88719214222655 SQ00.D01 Dye Squeezer HMX Cannula, Ophthalmic 1 VitreQ
2 88719214220859 BF23.D05 23G Retractable Brush BF-Instrument HMX Cannula, Ophthalmic 1 VitreQ
3 88719214220835 BF23.D02 23G Brush Backflush Instrument HMX Cannula, Ophthalmic 1 VitreQ
4 88719214222556 LP25.I05 25G (90°) Directional Illuminated Laser Probes, Iridex® Compatible MPA,HQF,HQB Endoilluminator,Laser, Ophthalmic,Photocoagulator And Accessories 2 VitreQ
5 88719214223454 CT00.D01 CryoTreQ HPS Unit, Cryophthalmic 2 VitreQ
6 88719214222723 FC27.D03 27G Forceps, ILM Endgripping HNR Forceps, Ophthalmic 1 VitreQ
7 88719214222679 SQ00.D02 PFC Squeezer HMX Cannula, Ophthalmic 1 VitreQ
8 88719214222617 LP27.I04 27G 90° Directional Laser Probes, Iridex® Style HQF,HQB Laser, Ophthalmic,Photocoagulator And Accessories 2 VitreQ
9 88719214222594 LP27.A04 25G (90°) Directional Laser Probes, Alcon® Compatible HQF,HQB Laser, Ophthalmic,Photocoagulator And Accessories 2 VitreQ
10 88719214222532 LP25.A05 25G (90°) Directional Illuminated Laser Probes, Alcon® Compatible MPA,HQF,HQB Endoilluminator,Laser, Ophthalmic,Photocoagulator And Accessories 2 VitreQ
11 88719214222495 LP25.I04 25G 90° Directional Laser Probes, Iridex® Compatible HQF,HQB Laser, Ophthalmic,Photocoagulator And Accessories 2 VitreQ
12 88719214222471 LP25.A04 25G 90° Directional Laser Probes, Alcon® Compatible HQF,HQB Laser, Ophthalmic,Photocoagulator And Accessories 2 VitreQ
13 88719214222433 LP23.I05 23G (90°) Directional Illuminated Laser Probes, Iridex® Compatible MPA,HQF,HQB Endoilluminator,Laser, Ophthalmic,Photocoagulator And Accessories 2 VitreQ
14 88719214222419 LP23.A05 23G (90°) Directional Illuminated Laser Probes, Alcon® Compatible MPA,HQF,HQB Endoilluminator,Laser, Ophthalmic,Photocoagulator And Accessories 2 VitreQ
15 88719214222372 LP23.I04 23G 90° Directional Laser Probes, Iridex® Compatible HQF,HQB Laser, Ophthalmic,Photocoagulator And Accessories 2 VitreQ
16 88719214222273 LF29.D02 29G Spotlight, Directional Chandelier MPA Endoilluminator 2 VitreQ
17 88719214222259 LF27.D03 27G 45° Shielded Light Fibers MPA Endoilluminator 2 VitreQ
18 88719214222235 LF27.D02 27G Wide View Light Fibers MPA Endoilluminator 2 VitreQ
19 88719214222211 LF27.D01 27G Standard Light Fibers MPA Endoilluminator 2 VitreQ
20 88719214222198 LF25.D03 25G 45° Shielded Light Fibers MPA Endoilluminator 2 VitreQ
21 88719214222174 LF25.D02 25G Wide View Light Fibers MPA Endoilluminator 2 VitreQ
22 88719214222150 LF25.D01 25G Standard Light Fibers MPA Endoilluminator 2 VitreQ
23 88719214222136 LF23.D03 23G 45° Shielded Light Fibers MPA Endoilluminator 2 VitreQ
24 88719214222112 LF23.D02 23G Wide View Light Fibers MPA Endoilluminator 2 VitreQ
25 88719214222099 LF23.D01 23G Standard Light Fibers MPA Endoilluminator 2 VitreQ
26 88719214221979 FC27.D07 27G Forceps, Shah Xtra Grip HNR Forceps, Ophthalmic 1 VitreQ
27 88719214221955 FC25.D07 25G Forceps, Shah Xtra Grip HNR Forceps, Ophthalmic 1 VitreQ
28 88719214221931 FC23.D07 23G Forceps, Shah Xtra Grip HNR Forceps, Ophthalmic 1 VitreQ
29 88719214221900 FC25.D06 25G Forceps, Kuhn 45° Power Gripping HNR Forceps, Ophthalmic 1 VitreQ
30 88719214221887 FC23.D06 23G Forceps, Kuhn 45° Power Gripping HNR Forceps, Ophthalmic 1 VitreQ
31 88719214221849 TM25.D01 25G Retractable Tissue Manipulator HND Spatula, Ophthalmic 1 VitreQ
32 88719214221825 TM23.D01 23G Retractable Tissue Manipulator HND Spatula, Ophthalmic 1 VitreQ
33 88719214221665 CN27.D05 27G Blunt Needles with luer-lock connector GAA Needle, Aspiration And Injection, Disposable 1 VitreQ
34 88719214221641 CN25.D05 25G Blunt Needles with luer-lock connector GAA Needle, Aspiration And Injection, Disposable 1 VitreQ
35 88719214221627 CN23.D05 23G Blunt Needles with luer-lock connector GAA Needle, Aspiration And Injection, Disposable 1 VitreQ
36 88719214221603 CN25.D04 25G Pick Needles GAA Needle, Aspiration And Injection, Disposable 1 VitreQ
37 88719214221580 CN23.D04 23G Pick Needles GAA Needle, Aspiration And Injection, Disposable 1 VitreQ
38 88719214221528 CN25.D01 25G Silicone Tipped Cannula HMX Cannula, Ophthalmic 1 VitreQ
39 88719214221504 CN23.D01 23G Silicone Tipped Cannula HMX Cannula, Ophthalmic 1 VitreQ
40 88719214221467 CN27.D03 27G VFI Cannula HMX Cannula, Ophthalmic 1 VitreQ
41 88719214221443 CN25.D03 25G VFI Cannula HMX Cannula, Ophthalmic 1 VitreQ
42 88719214221429 CN23.D03 23G VFI Cannula HMX Cannula, Ophthalmic 1 VitreQ
43 88719214221382 MD25.D01 25G PFC Injection Needle GAA Needle, Aspiration And Injection, Disposable 1 VitreQ
44 88719214221368 MD23.D01 23G PFC Injection Needle GAA Needle, Aspiration And Injection, Disposable 1 VitreQ
45 88719214221184 BF25.D52 25G BF Brush Needles GAA Needle, Aspiration And Injection, Disposable 1 VitreQ
46 88719214221160 BF25.D51 25G BF Blunt Needles GAA Needle, Aspiration And Injection, Disposable 1 VitreQ
47 88719214221146 BF23.D52 23G BF Brush Needles GAA Needle, Aspiration And Injection, Disposable 1 VitreQ
48 88719214221122 BF23.D51 23G BF Blunt Needles GAA Needle, Aspiration And Injection, Disposable 1 VitreQ
49 88719214221061 BF00.D53 Disposable Tubing for Active Aspiration HMX Cannula, Ophthalmic 1 VitreQ
50 88719214221047 BF00.D52 Backflush Reservoirs, Active HMX Cannula, Ophthalmic 1 VitreQ
Other products with the same Product Codes "HQF, HQB"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 05055272720380 1205-P-2180 577nm LIO KEELER LIMITED
2 05055272720328 1205-P-2170 514/810nm LIO KEELER LIMITED
3 05055272719674 1205-P-2130 532nm LIO KEELER LIMITED
4 04987669101650 17148-K020 delivery unit is connected to the laser photocoagulator and YAG laser system to delivery unit is connected to the laser photocoagulator and YAG laser system to comprise the photocoagulation system and to treat affected areas using a slit lamp.The photocoagulation system enables photocoagulation using a green laser beam (532 nm) or photodisruption using a Nd:YAG laser beam (1064 nm, hereafter referred to as “YAG laser beam”) or SLT laser (532 nm, for YC-200 S plus only) while observing the patient’s eye with the slit lamp. YAG laser combination delivery unit (YC-200) NIDEK CO.,LTD.
5 04987669101452 YC-200 The OPHTHALMIC YAG LASER SYSTEM YC-200 is an ophthalmic pulsed-laser system cons The OPHTHALMIC YAG LASER SYSTEM YC-200 is an ophthalmic pulsed-laser system consisting of a main body containing the laser, a head rest, a control box, and a connector box. The device uses a 1,064 nm pulsed Nd: YAG laser as the treatment beam source. Laser pulses are generated using a method called passive Q-switching. With this method, short high-power pulses can be emitted. At the target, the emitted pulses cause photodisruption, which is fragmentation of tissue using light energy. Ophthalmic YAG Laser System NIDEK CO.,LTD.
6 04987669101216 GEC01 The delivery unit is connected to the YELLOW LASER PHOTOCOAGULATOR YLC-500 to co The delivery unit is connected to the YELLOW LASER PHOTOCOAGULATOR YLC-500 to comprise the photocoagulation system and to treat affected areas using a slit lamp. The photocoagulation system enables photocoagulation using a yellow laser beam (577 nm) while observing the patient’s eye with the slit lamp. In order to reduce damages to the ocular media, the optical system (SOLIC *1) that ensures low laser power density on the anterior segment is incorporated. The ZEISS SL130 type is available.A delivery unit to be attached to an existing slit lamp mounted on an existing motorized optical table. The delivery unit is then connected to the main laser device to comprise the photocoagulation system (with the scan function). The HAAG BQ900 type type is available: *1 Safety Optics with Low Impact on Cornea Scan Attachable delivery unit (900BQ) NIDEK CO.,LTD.
7 04987669101186 GEB01 The delivery unit is connected to the YELLOW LASER PHOTOCOAGULATOR YLC-500 to co The delivery unit is connected to the YELLOW LASER PHOTOCOAGULATOR YLC-500 to comprise the photocoagulation system and to treat affected areas using a slit lamp. The photocoagulation system enables photocoagulation using a yellow laser beam (577 nm) while observing the patient’s eye with the slit lamp. In order to reduce damages to the ocular media, the optical system (SOLIC *1) that ensures low laser power density on the anterior segment is incorporated.*1 Safety Optics with Low Impact on Cornea Scan slit lamp delivery unit (NIDEK SL) NIDEK CO.,LTD.
8 04987669101179 GEA01 The delivery unit is connected to the YELLOW LASER PHOTOCOAGULATOR YLC-500 to co The delivery unit is connected to the YELLOW LASER PHOTOCOAGULATOR YLC-500 to comprise the photocoagulation system and to treat affected areas using a slit lamp. The photocoagulation system enables photocoagulation using a yellow laser beam (577 nm) while observing the patient’s eye with the slit lamp. In order to reduce damages to the ocular media, the optical system (SOLIC *1) that ensures low laser power density on the anterior segment is incorporated. The ZEISS SL130 type is available.A delivery unit to be attached to an existing slit lamp mounted on an existing motorized optical table. The delivery unit is then connected to the main laser device to comprise the photocoagulation system (with the scan function). The ZEISS SL130 type is available: *1 Safety Optics with Low Impact on Cornea Scan Attachable delivery unit (SL130) NIDEK CO.,LTD.
9 04987669101162 GDD01 The delivery unit is connected to the Yellow Laser Photocoagulator YLC-500 to co The delivery unit is connected to the Yellow Laser Photocoagulator YLC-500 to comprise the photocoagulation system and to treat affected areas using a binocular indirect ophthalmoscope. The photocoagulation system enables photocoagulation using a yellow laser beam (577 nm) while observing the patient’s eye with the binocular indirect ophthalmoscope. Bio delivery unit (OMEGA 500) NIDEK CO.,LTD.
10 04987669101131 GDB01 The delivery unit is connected to the YELLOW LASER PHOTOCOAGULATOR YLC-500 to co The delivery unit is connected to the YELLOW LASER PHOTOCOAGULATOR YLC-500 to comprise the photocoagulation system and to treat affected areas using a slit lamp. The photocoagulation system enables photocoagulation using a yellow laser beam (577 nm) while observing the patient’s eye with the slit lamp. In order to reduce damages to the ocular media, the optical system (SOLIC *1) that ensures low laser power density on the anterior segment is incorporated.*1 Safety Optics with Low Impact on Cornea Slit lamp delivery unit (NIDEK SL) NIDEK CO.,LTD.
11 04987669101124 GDA01 The delivery unit is connected to the YELLOW LASER PHOTOCOAGULATOR YLC-500 to co The delivery unit is connected to the YELLOW LASER PHOTOCOAGULATOR YLC-500 to comprise the photocoagulation system and to treat affected areas using a slit lamp. The photocoagulation system enables photocoagulation using a yellow laser beam (577 nm) while observing the patient’s eye with the slit lamp. In order to reduce damages to the ocular media, the optical system (SOLIC *1) that ensures low laser power density on the anterior segment is incorporated. The ZEISS SL130 type is available.*1 Safety Optics with Low Impact on Cornea Attachable delivery unit (SL130) NIDEK CO.,LTD.
12 04987669101117 YLC-500 The NIDEK YELLOW LASER PHOTOCOAGULATOR YLC-500 is an ophthalmic laser photocoagu The NIDEK YELLOW LASER PHOTOCOAGULATOR YLC-500 is an ophthalmic laser photocoagulator consisting of a main laser device, a control box, and a power supply. With various types of laser delivery units, it comprises a photocoagulation system. The YLC-500 uses a 577 nm optically pumped semiconductor laser (yellow laser beam) as the treatment beam source. The pumped yellow laser beam (treatment beam) and the aiming beam (635 nm, red laser beam) are fed coaxially into the fiber optic cable. The output terminal of the fiber optic cable is connected to a delivery unit. The laser beam is formed into the desired spot size by the optical system, then the laser beam is emitted to the target area. The delivery units are equipped with a protective filter that protects the physician’s eyes from exposure to the treatment beam reflected from the patient’s eye or contact lens. Yellow Laser Photocoagulator NIDEK CO.,LTD.
13 04987669100981 11143-0000(9M5P) The delivery unit is used for endophotocoagulation. The photocoagulation system The delivery unit is used for endophotocoagulation. The photocoagulation system can be easily comprised by connecting the optional sterilized endophotoprobe or optional sterilized coaxial illumination probe to the Multicolor Laser Photocoagulator System MC-500, and attaching the protective filter to the main laser device as well as the surgical microscope. This photocoagulation system enables laser endophotocoagulation while observing the affected area through the surgical microscope. Endophotocoagulation Delivery Unit NIDEK CO.,LTD.
14 04987669100974 11143-0000(9G4P) The delivery unit is used for endophotocoagulation. The photocoagulation system The delivery unit is used for endophotocoagulation. The photocoagulation system can be easily comprised by connecting the optional sterilized endophotoprobe or optional sterilized coaxial illumination probe to the Green Laser Photocoagulator GYC-1000 and GYC-500, and attaching the protective filter to the main laser device as well as the surgical microscope. This photocoagulation system enables laser endophotocoagulation while observing the affected area through the surgical microscope. Endophotocoagulation Delivery Unit NIDEK CO.,LTD.
15 04987669100967 17166-6100 Expansion box is the optional accessory that is used to connect a scan delivery Expansion box is the optional accessory that is used to connect a scan delivery unit and the external devices (LAN cable, barcode scanner, or magnetic card reader) to the GYC-500. Expansion box NIDEK CO.,LTD.
16 04987669100950 17428-0000 The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to com The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to comprise the photocoagulation system and to treat affected areas using a slit lamp. The photocoagulation system enables photocoagulation using a green laser beam (532 nm) while observing the patient’s eye with the slit lamp. In order to reduce damages to the ocular media, the optical system that ensures low laser power density on the anterior segment is incorporated.configuration in which the delivery unit comes together with a slit lamp mounted on a motorized optical table so that the photocoagulation system (with the scan function) can be comprised by simply connecting to the main laser device. NIDEK SL-1800 type is available. Scan slit lamp delivery unit (SL-1800) NIDEK CO.,LTD.
17 04987669100943 17457-0000 The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to com The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to comprise the photocoagulation system and to treat affected areas using a slit lamp. The photocoagulation system enables photocoagulation using a green laser beam (532 nm) while observing the patient’s eye with the slit lamp. In order to reduce damages to the ocular media, the optical system that ensures low laser power density on the anterior segment is incorporated. A delivery unit to be attached to an existing slit lamp mounted on an existing motorized optical table. The delivery unit is then connected to the main laser device to comprise the photocoagulation system (with the scan function). HAAG 900 BQ type is available. Scan attachable delivery unit (900BQ) NIDEK CO.,LTD.
18 04987669100936 17454-0000 The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to com The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to comprise the photocoagulation system and to treat affected areas using a slit lamp. The photocoagulation system enables photocoagulation using a green laser beam (532 nm) while observing the patient’s eye with the slit lamp. In order to reduce damages to the ocular media, the optical system that ensures low laser power density on the anterior segment is incorporated. A delivery unit to be attached to an existing slit lamp mounted on an existing motorized optical table. The delivery unit is then connected to the main laser device to comprise the photocoagulation system (with the scan function). ZEISS SL130 type is available. Scan attachable delivery unit (SL130) NIDEK CO.,LTD.
19 04987669100929 17452-0000 The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to com The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to comprise the photocoagulation system and to treat affected areas using a slit lamp. The photocoagulation system enables photocoagulation using a green laser beam (532 nm) while observing the patient’s eye with the slit lamp. In order to reduce damages to the ocular media, the optical system that ensures low laser power density on the anterior segment is incorporated. A delivery unit to be attached to an existing slit lamp mounted on an existing motorized optical table. The delivery unit is then connected to the main laser device to comprise the photocoagulation system (with the scan function). NIDEK SL-1800 type is available. Scan attachable delivery unit (SL-1800) NIDEK CO.,LTD.
20 04987669100912 17451-0000 The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to com The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to comprise the photocoagulation system and to treat affected areas using a slit lamp. The photocoagulation system enables photocoagulation using a green laser beam (532 nm) while observing the patient’s eye with the slit lamp. In order to reduce damages to the ocular media, the optical system that ensures low laser power density on the anterior segment is incorporated. A delivery unit to be attached to an existing slit lamp mounted on an existing motorized optical table. The delivery unit is then connected to the main laser device to comprise the photocoagulation system (with the scan function). ZEISS 30 SL type is available. Scan attachable delivery unit (30SL/M) NIDEK CO.,LTD.
21 04987669100905 17441-0000 The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to com The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to comprise the photocoagulation system and to treat affected areas using a slit lamp. The photocoagulation system enables photocoagulation using a green laser beam (532 nm) while observing the patient’s eye with the slit lamp. In order to reduce damages to the ocular media, the optical system that ensures low laser power density on the anterior segment is incorporated.A delivery unit to be attached to an existing slit lamp mounted on an existing motorized optical table. The delivery unit is then connected to the main laser device to comprise the photocoagulation system. HAAG 900 series type is available. Attachable delivery unit (900BQ) NIDEK CO.,LTD.
22 04987669100899 17434-0000 The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to com The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to comprise the photocoagulation system and to treat affected areas using a slit lamp. The photocoagulation system enables photocoagulation using a green laser beam (532 nm) while observing the patient’s eye with the slit lamp. In order to reduce damages to the ocular media, the optical system that ensures low laser power density on the anterior segment is incorporated.A delivery unit to be attached to an existing slit lamp mounted on an existing motorized optical table. The delivery unit is then connected to the main laser device to comprise the photocoagulation system.ZEISS SL130 type is available. Attachable delivery unit (SL130) NIDEK CO.,LTD.
23 04987669100882 17432-0000 The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to com The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to comprise the photocoagulation system and to treat affected areas using a slit lamp. The photocoagulation system enables photocoagulation using a green laser beam (532 nm) while observing the patient’s eye with the slit lamp. In order to reduce damages to the ocular media, the optical system that ensures low laser power density on the anterior segment is incorporated.A delivery unit to be attached to an existing slit lamp mounted on an existing motorized optical table. The delivery unit is then connected to the main laser device to comprise the photocoagulation system. NIDEK SL-1800 type is available. Attachable delivery unit (SL-1800) NIDEK CO.,LTD.
24 04987669100875 17431-0000 The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to com The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to comprise the photocoagulation system and to treat affected areas using a slit lamp. The photocoagulation system enables photocoagulation using a green laser beam (532 nm) while observing the patient’s eye with the slit lamp. In order to reduce damages to the ocular media, the optical system that ensures low laser power density on the anterior segment is incorporated.A delivery unit to be attached to an existing slit lamp mounted on an existing motorized optical table. The delivery unit is then connected to the main laser device to comprise the photocoagulation system. The ZEISS 30 SL type is availabe. Attachable delivery unit (30SL/M) NIDEK CO.,LTD.
25 04987669100868 17426-0000 The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to com The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to comprise the photocoagulation system and to treat affected areas using the SLIT LAMP SL-1800. The photocoagulation system enables photocoagulation using a green laser beam (532 nm) while observing the patient’s eye with the slit lamp. In order to reduce damages to the ocular media, the optical system that ensures low laser power density on the anterior segment is incorporated.A configuration in which the delivery unit comes together with a slit lamp mounted on a motorized optical table so that the photocoagulation system can be comprised by simply connecting to the main laser device. Slit lamp delivery unit (SL-1800) NIDEK CO.,LTD.
26 04987669100851 GYC-500 The NIDEK Green Laser Photocoagulator GYC-500 is a laser photocoagulator for oph The NIDEK Green Laser Photocoagulator GYC-500 is a laser photocoagulator for ophthalmology using a 532 nm diode-pumped solid-state laser (green laser beam) as the treatment beam source. The device incorporates a diode-pumped laser that enables efficient laser beam emission at 532 nm. For the laser beam delivery, various types of delivery units may be employed. This allows performance of transpupillary photocoagulation using a slit lamp or binocular indirect ophthalmoscope. Green Laser Photocoagulator NIDEK CO.,LTD.
27 04987669100196 17482-0000 This delivery unit is connected to the NIDEK Multicolor Laser Photocoagulator, M This delivery unit is connected to the NIDEK Multicolor Laser Photocoagulator, Model MC-500 main body to comprise the photocoagulation system and to treat affected areas using the slit lamp, NIDEK SL-1800/SL-1600. A scan slit lamp delivery unit that includes the SL-1800 comprises a photocoagulation system in connection with the MC-500 main body. A scan attachable delivery unit is mainly comprised of a photocoagulation unit and a protective filter unit. They are attached to the NIDEK SL-1800/SL-1600 slit lamp for lasers to comprise a scan slit lamp delivery unit. The comprised scan slit lamp delivery unit is connected to the MC-500 to comprise a photocoagulation system. A photocoagulation system allows the operator to select among photocoagulation with the red (647 nm), yellow (577 nm), or green (532 nm) laser beam and observation of the affected area with the slit lamp. Scan slit lamp delivery unit (SL-1800) NIDEK CO.,LTD.
28 04987669100189 17468-0000 The scan attachable delivery unit is mainly comprised of a photocoagulation unit The scan attachable delivery unit is mainly comprised of a photocoagulation unit and a protective filter unit. They are attached to the HAAG 900BQ slit lamp to comprise a scan slit lamp delivery unit. The comprised scan slit lamp delivery unit is connected to the NIDEK Multicolor Laser Photocoagulator,Model MC-500 main body to comprise the photocoagulation system. A photocoagulation system allows the operator to select among photocoagulation with the red (647 nm), yellow (577 nm), or green (532 nm) laser beam and observation of the affected area with the slit lamp. Scan attachable delivery unit (900BQ) NIDEK CO.,LTD.
29 04987669100172 17467-0000 The scan attachable delivery unit is mainly comprised of a photocoagulation unit The scan attachable delivery unit is mainly comprised of a photocoagulation unit and a protective filter unit. They are attached to the Carl Zeiss Meditec SL 130 (Zeiss SL 130) to comprise a scan slit lamp delivery unit. The comprised scan slit lamp delivery unit is connected to the NIDEK Multicolor Laser Photocoagulator, Model MC-500 to comprise a photocoagulation system. The photocoagulation system allows the operator to select among photocoagulation with the red (647 nm), yellow (577 nm), or green (532 nm) laser beam and observation of the affected area with the slit lamp. Scan attachable delivery unit (SL130) NIDEK CO.,LTD.
30 04987669100165 17466-0000 This delivery unit is connected to the NIDEK Multicolor Laser Photocoagulator, M This delivery unit is connected to the NIDEK Multicolor Laser Photocoagulator, Model MC-500 main body to comprise the photocoagulation system and to treat affected areas using the slit lamp, NIDEK SL-1800/SL-1600. A scan attachable delivery unit is mainly comprised of a photocoagulation unit and a protective filter unit. They are attached to the NIDEK SL-1800/SL-1600 slit lamp for lasers to comprise a scan slit lamp delivery unit. The comprised scan slit lamp delivery unit is connected to the MC-500 to comprise a photocoagulation system. A photocoagulation system allows the operator to select among photocoagulation with the red (647 nm), yellow (577 nm), or green (532 nm) laser beam and observation of the affected area with the slit lamp. Scan attachable delivery unit (SL-1800) NIDEK CO.,LTD.
31 04987669100158 17465-0000 The attachable delivery unit is attached to the Carl Zeiss 30SL/M (hereafter cal The attachable delivery unit is attached to the Carl Zeiss 30SL/M (hereafter called Zeiss 30SL/M) to comprise a slit lamp delivery unit. The comprised scan slit lamp delivery unit is connected to the MC-500 to comprise a photocoagulation system. The photocoagulation system allows the operator to select among photocoagulation with the red (647 nm), yellow (577 nm), or green (532 nm) laser beam and observation of the affected area with the slit lamp. The attachable delivery unit is mainly comprised of a photocoagulation unit, a protective filter unit, and a split mirror illumination unit. Scan attachable delivery unit (30SL/M) NIDEK CO.,LTD.
32 04987669100141 17464-0000 The attachable delivery unit is attached to the Carl Zeiss Meditec SL 130 (herea The attachable delivery unit is attached to the Carl Zeiss Meditec SL 130 (hereafter called Zeiss SL 130) to comprise a slit lamp delivery unit. The comprised slit lamp delivery unit is connected to the NIDEK Multicolor Laser Photocoagulator, Model MC-500 to comprise a photocoagulation system.The photocoagulation system allows the operator to select among photocoagulation with the red (647 nm), yellow (577 nm), or green (532 nm) laser beam and observation of the affected area with the slit lamp. The attachable delivery unit is mainly comprised of a photocoagulation unit, a protective filter unit, and a split mirror illumination unit. Attachable delivery unit (SL130) NIDEK CO.,LTD.
33 04987669100134 17462-0000 This delivery unit is connected to the NIDEK Multicolor Laser Photocoagulator, M This delivery unit is connected to the NIDEK Multicolor Laser Photocoagulator, Model MC-500 main body to comprise the photocoagulation system and to treat affected areas using the slit lamp, NIDEK SL-1800/SL-1600. A slit lamp delivery unit that includes the SL-1800 comprises a photocoagulation system in connection with the MC-500 main body. A attachable delivery unit is mainly comprised of a photocoagulation unit and a protective filter unit.They are attached to the NIDEK SL-1800/SL-1600 slit lamp for lasers to comprise a slit lamp delivery unit. The comprised slit lamp delivery unit is connected to the MC-500 to comprise a photocoagulation system. A photocoagulation system allows the operator to select among photocoagulation with the red (647 nm), yellow (577 nm), or green (532 nm) laser beam and observation of the affected area with the slit lamp. Attachable delivery unit (SL-1800) NIDEK CO.,LTD.
34 04987669100127 17461-0000 This delivery unit is connected to the NIDEK Multicolor Laser Photocoagulator, M This delivery unit is connected to the NIDEK Multicolor Laser Photocoagulator, Model MC-500 main body, to comprise the photocoagulation system and to treat affected areas using the slit lamp, Carl Zeiss Meditec 30 SL/M. This delivery unit is mainly comprised of the delivery unit, protective filter unit, and the split illumination mirror unit. This photocoagulation system allows the operator to select among photocoagulation with the red (647 nm), yellow (577 nm), or green (532 nm) laser beam and observation of the affected area with the slit lamp. This delivery unit can be attached only to the Carl Zeiss Meditec 30 SL/M. Attachable delivery unit (30SL) NIDEK CO.,LTD.
35 04987669100110 17379-0000 The Binocular Indirect Ophthalmoscope (hereafter called BIO) delivery unit is co The Binocular Indirect Ophthalmoscope (hereafter called BIO) delivery unit is connected to the NIDEK Multicolor Laser Photocoagulator, Model MC-500 (main body), to comprise the photocoagulation system and applied to the treatment of the affected area using the BIO delivery unit (HEINE OMEGA 500). The comprised photocoagulation system allows the operator to select between thermal photocoagulation with the multicolor laser beam (treatment beam) (wavelength: green (532 nm), yellow (577 nm), and red (647nm)) and observation with the BIO. BIO delivery unit (Heine OMEGA) NIDEK CO.,LTD.
36 04987669100103 17367-0000 This combination delivery unit is need to comprise the combination system which This combination delivery unit is need to comprise the combination system which enables radiation of the red, yellow, or green laser beam or YAG laser beam while performing the observation with the slit lamp of the YAG laser system. This delivery unit is mounted on the slit lamp of the YAG laser system and connected to the NIDEK Multicolor Laser Photocoagulator MC-500 using the MC connecting cable and fiber optic cable. The combination system allows selection between photocoagulation with the red (647 nm), yellow (577 nm), or green (532 nm) laser beam and YAG laser beam (wavelength: 1064 nm (pulse laser)). In addition, they are selected easily by changing the optical path of the laser beam with the laser selectlever, and various kinds of safety devices are integrated into the system to make sure that only the selected laser beam is radiated. This combination delivery unit is the only delivery unit that can be connected both to the NIDEK Multicolor Laser Photocoagulator MC-500 and the NIDEK Ophthalmic YAG Laser System YC-1800. YAG laser combination delivery unit (YC-1800) NIDEK CO.,LTD.
37 04987669100097 17481-0000 This delivery unit is connected to the NIDEK Multicolor Laser Photocoagulator, M This delivery unit is connected to the NIDEK Multicolor Laser Photocoagulator, Model MC-500 main body to comprise the photocoagulation system and to treat affected areas using the slit lamp, NIDEK SL-1800. A slit lamp delivery unit that includes the SL-1800 comprises a photocoagulation system in connection with the MC-500 main body. Slit lamp delivery unit (SL-1800) NIDEK CO.,LTD.
38 04987669100080 MC-500 The NIDEK Multicolor Laser Photocoagulator MC-500 is a laser photocoagulator for The NIDEK Multicolor Laser Photocoagulator MC-500 is a laser photocoagulator for ophthalmology with the light source of wavelengths 647, 577, and 532 nm. As the conventional laser photocoagulators, the MC-500 can be used for retinal photocoagulation for treatment of ocular fundus diseases like diabetic retinopathy, age-related macular degeneration, retinopathy of prematurity, and retinal detachment, or for laser iridotomy and laser trabeculoplasty for treatment of glaucoma. The device incorporates two types of lasers (diode-pumped solid state laser and laser diode) which enable efficient obtainment of laser beam oscillation of each wavelength. As the conventional device, various types of laser delivery units can be used. Therefore, transpupillary photocoagulation can be performed using various delivery units such as slit lamps and binocular indirect ophthalmoscope. Multicolor Laser Photocoagulator NIDEK CO.,LTD.
39 04712826771083 ST0026 Lightlas SeLecTor Deux LIGHTMED CORPORATION
40 04712826771076 ST0025 Lightlas SeLecTor Deux LIGHTMED CORPORATION
41 04712826771069 YL0027 SYL-9000 YAG Laser LIGHTMED CORPORATION
42 04712826771052 YL0026 SYL-9000 YAG Laser LIGHTMED CORPORATION
43 04712826771014 YC0001(2W) LightLas 561 LIGHTMED CORPORATION
44 04712826771007 TP0022 TruScan Pro LIGHTMED CORPORATION
45 04712826770994 TP0021 TruScan Pro LIGHTMED CORPORATION
46 04712826770987 TP0016 TruScan Pro LIGHTMED CORPORATION
47 04712826770970 TP0013 TruScan Pro LIGHTMED CORPORATION
48 04712826770963 ST0024 Lightlas SeLecTor Deux LIGHTMED CORPORATION
49 04712826770956 ST0023 Lightlas SeLecTor Deux LIGHTMED CORPORATION
50 04712826770949 ST0022 Lightlas SeLecTor Deux LIGHTMED CORPORATION