Reusable peripheral electrodes for ECG, 31.5x22mm dimensions, have features that
Reusable peripheral electrodes for ECG, 31.5x22mm dimensions, have features that make them absolutely reliable during signal recording with all different ECG recorders on the market. The metallic part is silver coated (Ag/AgCl) allowing a safe and clear signal transmission. F9010SSC-6 thanks to screw and snap connections, can be tapped to all ECG recorders and monitors both with plug and snap. To be used with fasten belts.The product is Latex-free and Nickel-free.
Disposable ECG RADIOLUCENT electrodes with liquid gel, 32x44mm dimensions, Silve
Disposable ECG RADIOLUCENT electrodes with liquid gel, 32x44mm dimensions, Silver/Silver Chloride (SSC) sensor and carbon snap. F9047RM model is suitable both for rest and stress or Holter ECG recording, with a direct application onto the skin.The SSC sensor permits a reliable and stable recording. The peculiar feature of the electrode is the carbon snap that makes it radiolucent. Neither of the components contains any ferromagnetic materials, therefore the electrodes are fully compatible with MRI applications. The electrodes are MRI tested for use up to 3 T electro-magnetic field. The use of the electrodes do not affect the safety and functioning of Magnetic Resonance Imaging Systems. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids
Disposable ECG RADIOLUCENT electrodes with solid gel, 28x44mm dimensions, Silver
Disposable ECG RADIOLUCENT electrodes with solid gel, 28x44mm dimensions, Silver/Silver Chloride(SSC) sensor and carbon snap. F9046RM model is suitable both for rest and stress or Holter ECG recording, with a direct application onto the skin. The SSC sensor permits a reliable and stable recording. The peculiar feature of the electrode is the carbon snap that makes it radiolucent. Neither of the components contains any ferromagnetic materials, therefore the electrodes are fully compatible with MRI applications. The electrodes are MRI tested for use up to 3 T electro-magnetic field. The use of the electrodes do not affect the safety and functioning of Magnetic Resonance Imaging Systems. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids
Disposable ECG electrodes, oval-shaped 50x48mm dimensions,Silver/Silver Chlori
Disposable ECG electrodes, oval-shaped 50x48mm dimensions,Silver/Silver Chloride(SSC) sensor and stainless steel snap. F9060 model is suitable for rest, long term, stress or Holter ECG recording, with a direct application onto the skin. The SSC sensor permits a reliable and stable recording. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids
Disposable ECG electrodes with solid gel, 28x44mm dimensions,Silver/Silver Chlo
Disposable ECG electrodes with solid gel, 28x44mm dimensions,Silver/Silver Chloride(SSC) sensor and stainless steel snap. F9046 model is suitable both for rest and stress or Holter ECG recording, with a direct application onto the skin. The SSC sensor permits a reliable and stable recording. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids.
Disposable oval-shaped ECG electrodes with liquid gel, Silver/Silver Chlor
Disposable oval-shaped ECG electrodes with liquid gel, Silver/Silver Chloride(SSC) sensor, 52x32mm dimensions and with 4mm socket . These electrodes dimensions have features that make them absolutely reliable during signal recording in rest tests, with a direct application onto the skin. The SSC sensor permits a reliable and stable recording and off-centered configuration allows a better quality of ECG signal and reduces artifacts. They comply with ANSI/AAMI EC12:2000 permitting the signal recovery after defibrillator discharge. After opening, the pouch can be folded to ensure a better preservation of the electrodes that remain inside. The products are latex-free.
Disposable round-shaped ECG electrodes with liquid gel, Ø 42mm, Silver/Sil
Disposable round-shaped ECG electrodes with liquid gel, Ø 42mm, Silver/Silver Chloride(SSC) sensor and metal snap. These electrodes are suitable for short and medium term monitoring, stress ECG recording and Holter, with a direct application onto the skin. The SSC sensor permits a reliable and stable recording and off-centered configuration allows a better quality of ECG signal and reduces artifacts.
Disposable round-shaped ECG electrodes with liquid gel, Ø 50mm, Silver/Sil
Disposable round-shaped ECG electrodes with liquid gel, Ø 50mm, Silver/Silver Chloride(SSC) sensor and metal snap. These electrodes are suitable for short and medium term monitoring, stress ECG recording and Holter, with a direct application onto the skin. The SSC sensor permits a reliable and stable recording and off-centered configuration allows a better quality of ECG signal and reduces artifacts.
Disposable round-shaped ECG electrodes with liquid gel, Ø 60mm, Silver/Sil
Disposable round-shaped ECG electrodes with liquid gel, Ø 60mm, Silver/Silver Chloride(SSC) sensor and metal snap. These electrodes are suitable for short and medium term monitoring, stress ECG recording and Holter, with a direct application onto the skin. The SSC sensor permits a reliable and stable recording and off-centered configuration allows a better quality of ECG signal and reduces artifacts.
F9057PRRM model is a disposable round-shaped ECG monitoring electrodes have feat
F9057PRRM model is a disposable round-shaped ECG monitoring electrodes have features that make them absolutely reliable during long monitoring ECG recording (not longer than 72 hours). F9057PRRM is pre-gelled, Ø 32mm, equipped with 50cm long wire and DIN 42802-1 1.5mm socket. The external surface is made of non woven fabric. The fabric is made of plastic polyethylene fiber (and not natural fiber) that guarantees the transpiration of the skin, but at the same time the resistance to liquids with which they may come into contact during their use. Neonatal and Premature model.F9057PRRM model is radiotranslucent, therefore it allows the user to perform radiographic procedures without removing the electrode.
F9057PR model is a disposable oval-shaped ECG monitoring electrodes have feature
F9057PR model is a disposable oval-shaped ECG monitoring electrodes have features that make them absolutely reliable during long monitoring ECG recording (not longer than 72 hours). F9057PR is pre-gelled, 20x15mm dimensions, equipped with 50cm long wire and DIN 42802-1 1.5mm socket. The external surface is made of non woven fabric. The fabric is made of plastic polyethylene fiber (and not natural fiber) that guarantees the transpiration of the skin, but at the same time the resistance to liquids with which they may come into contact during their use. Neonatal and premature model.
F9057NRM model is a disposable oval-shaped ECG monitoring electrodes have featur
F9057NRM model is a disposable oval-shaped ECG monitoring electrodes have features that make them absolutely reliable during long monitoring ECG recording (not longer than 72 hours). F9057NRM is pre-gelled, 23x30mm dimensions, equipped with 50cm long wire and DIN 42802-1 1.5mm socket. The external surface is made of non woven fabric. The fabric is made of plastic polyethylene fiber (and not natural fiber) that guarantees the transpiration of the skin, but at the same time the resistance to liquids with which they may come into contact during their use. Pediatric and Neonatal model.F9057NRM model is radiotranslucent, therefore it allows the user to perform radiographic procedures without removing the electrode.
F9057N model is a disposable oval-shaped ECG monitoring electrodes have features
F9057N model is a disposable oval-shaped ECG monitoring electrodes have features that make them absolutely reliable during long monitoring ECG recording (not longer than 72 hours). F9057N is pre-gelled, 23x30mm dimensions, equipped with 50cm long wire and DIN 42802-1 1.5mm socket. The external surface is made of non woven fabric. The fabric is made of plastic polyethylene fiber (and not natural fiber) that guarantees the transpiration of the skin, but at the same time the resistance to liquids with which they may come into contact during their use.Pediatric and Neonatal model.
F9057PRM model is a disposable round-shaped ECG monitoring electrodes have featu
F9057PRM model is a disposable round-shaped ECG monitoring electrodes have features that make them absolutely reliable during long monitoring ECG recording (not longer than 72 hours). F9057PRM is pre-gelled, Ø 32mm, equipped with 50cm long wire and DIN 42802-1 1.5mm socket. The external surface is made of non woven fabric. The fabric is made of plastic polyethylene fiber (and not natural fiber) that guarantees the transpiration of the skin, but at the same time the resistance to liquids with which they may come into contact during their use. Adult and Pediatric model.F9057PRM model is radiotranslucent, therefore it allows the user to perform radiographic procedures without removing the electrode.
F9057P model is a disposable round-shaped ECG monitoring electrodes have feature
F9057P model is a disposable round-shaped ECG monitoring electrodes have features that make them absolutely reliable during long monitoring ECG recording (not longer than 72 hours). F9057P is pre-gelled, Ø 32mm and equipped with 50cm long wire with DIN 42802-1 1.5mm socket. The external surface is made of non woven fabric. The fabric is made of plastic polyethylene fiber (and not natural fiber) that guarantees the transpiration of the skin, but at the same time the resistance to liquids with which they may come into contact during their use.
Disposable ECG electrodes, oval-shaped 50x48mm dimensions,Silver/Silver Chlori
Disposable ECG electrodes, oval-shaped 50x48mm dimensions,Silver/Silver Chloride(SSC) sensor and stainless steel snap. F9060/5 model is suitable for rest, long term, stress or Holter ECG recording, with a direct application onto the skin. The SSC sensor permits a reliable and stable recording. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids
Reusable peripheral clamp electrodes for ECG, 30x130mm clamp dimensions. F9024SS
Reusable peripheral clamp electrodes for ECG, 30x130mm clamp dimensions. F9024SSC2W has features that make it absolutely reliable during signal recording with all different ECG devices on the market. The electrode metallic part is made of silver coated material, allowing a safe and clear signal transmission. FIAB peripheral electrodes, thanks to screw and clip connections, can be connected to all ECG devices and monitors with patient cable which have plug or snap connections. Two white clamp packaging.The product is latex-free and without Nickel.
Disposable ECG monitoring electrodes have features that make them abs
Disposable ECG monitoring electrodes have features that make them absolutely reliable during long monitoring ECG recording (not longer than 72 hours). F9053N/55 model is oval-shaped electrodes, 30x23mm dimensions, equipped with 55cm long wire and 4mm socket, pre-gelled and it can be easily connected to the ECG monitor, avoiding pressure on the skin. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids.
Disposable ECG monitoring electrodes have features that make them abs
Disposable ECG monitoring electrodes have features that make them absolutely reliable during long monitoring ECG recording (not longer than 72 hours). F9053P/55 model is round-shaped electrodes, Ø 32mm, equipped with 55cm long wire and 4mm socket, pre-gelled and it can be easily connected to the ECG monitor, avoiding pressure on the skin. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids.
F9070RM model is disposable ECG RADIOLUCENT electrode with solid gel, rou
F9070RM model is disposable ECG RADIOLUCENT electrode with solid gel, round-shaped Ø 50mm, Silver/Silver Chloride (SSC) sensor and carbon snapThe SSC sensor permits a reliable and stable recording. The peculiar feature of the electrode is the carbon snap that makes it radiolucent. Neither of the components contains any ferromagnetic materials, therefore the electrodes are fully compatible with MRI applications. The electrodes are MRI tested for use up to 3 T electro-magnetic field. The use of the electrodes do not affect the safety and functioning of Magnetic Resonance Imaging Systems. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids
Disposable ECG pediatric electrodes with solid gel, 36x32mm dimension, Silver/Si
Disposable ECG pediatric electrodes with solid gel, 36x32mm dimension, Silver/Silver Chloride(SSC) sensor and stainless steel snap. F9089P/100 model are suitable both for rest and stress or Holter ECG recording, with a direct application onto the skin. The SSC sensor permits a reliable and stable recording and permits the signal recovery after defibrillator discharge . The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids.
Disposable ECG electrodes with solid gel, 40x36mm dimension, Silver/Silver Chlor
Disposable ECG electrodes with solid gel, 40x36mm dimension, Silver/Silver Chloride(SSC) sensor and stainless steel snap. F9089/100 model are suitable both for rest and stress or Holter ECG recording, with a direct application onto the skin. The SSC sensor permits a reliable and stable recording and permits the signal recovery after defibrillator discharge . The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids.
Disposable ECG electrodes with solid gel and SSC sensor, oval-shaped 32x36mm and
Disposable ECG electrodes with solid gel and SSC sensor, oval-shaped 32x36mm and and stainless steel snap. F9079P/100 model is suitable both for rest and stress or Holter ECG recording, with a direct application onto the skin. The SSC sensor permits a reliable and stable recording. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids.
Disposable ECG electrodes, oval-shaped 48x34mm dimensions with solid gel,
Disposable ECG electrodes, oval-shaped 48x34mm dimensions with solid gel, Silver/Silver Chloride (SSC) sensor and stainless steel snap. F9049/100 model is suitable for rest, long term, stress or Holter ECG recording, with a direct application onto the skin. The SSC sensor permits a reliable and stable recording. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids.
Disposable ECG monitoring electrodes have features that make them abs
Disposable ECG monitoring electrodes have features that make them absolutely reliable during long monitoring ECG recording (not longer than 72 hours). F9053PRRM/80 model are oval-shaped electrodes, 20x15mm dimensions, equipped with 80cm long wire and 4mm socket, pre-gelled and they can be easily connected to the ECG monitor, avoiding pressure on the skin. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids.F9053PRRM/80 model is radiotranslucent, therefore it allows the user to perform radiographic procedures without removing the electrode.
Disposable ECG electrodes with solid gel, round-shaped Ø 40mm, Silver/Silver Ch
Disposable ECG electrodes with solid gel, round-shaped Ø 40mm, Silver/Silver Chloride(SSC) sensor and stainless steel snap. F2080P model is is made of non woven fabric. The fabric is made of plastic polyethylene fiber (and not natural fiber) that guarantees the transpiration of the skin, but at the same time the resistance to liquids with which they may come into contact during their use. F2080P is suitable for rest, long term, stress or Holter ECG recording, with a direct application onto
Disposable ECG electrodes with solid gel, round-shaped Ø 55mm, Silver/Silver Ch
Disposable ECG electrodes with solid gel, round-shaped Ø 55mm, Silver/Silver Chloride(SSC) sensor and stainless steel snap. F2080 model is is made of non woven fabric. The fabric is made of plastic polyethylene fiber (and not natural fiber) that guarantees the transpiration of the skin, but at the same time the resistance to liquids with which they may come into contact during their use. F2080 is suitable for rest, long term, stress or Holter ECG recording, with a direct application onto the skin.
Disposable ECG electrodes with solid gel, 57x34mm dimensions, Silver/Silver Chl
Disposable ECG electrodes with solid gel, 57x34mm dimensions, Silver/Silver Chloride(SSC) sensor and stainless steel snap. F9048 model is suitable both for rest and stress or Holter ECG recording, with a direct application onto the skin. The SSC sensor permits a reliable and stable recording. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids
Disposable ECG monitoring electrodes have features that make them abs
Disposable ECG monitoring electrodes have features that make them absolutely reliable during long monitoring ECG recording (not longer than 72 hours). F9053PR model is oval-shaped electrodes, 20x15mm dimensions, equipped with 35cm long wire and 4mm socket, pre-gelled and they can be easily connected to the ECG monitor, avoiding pressure on the skin. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids.
Disposable ECG monitoring electrodes have features that make them abs
Disposable ECG monitoring electrodes have features that make them absolutely reliable during long monitoring ECG recording (not longer than 72 hours). F9058/90NRM model is oval-shaped electrodes, 30x23mm dimensions,pre-gelled, equipped with 90cm long wire and DIN 42802-1 1.5mm socket. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids.F9058/90NRM is radiotranslucent model that allows the user to perform radiographic procedures without removing the electrode.
F9069NRM model is disposable ECG RADIOLUCENT electrode with solid gel, ro
F9069NRM model is disposable ECG RADIOLUCENT electrode with solid gel, round-shaped Ø 26mm, Silver/Silver Chloride (SSC) sensor and carbon snap.The SSC sensor permits a reliable and stable recording. The peculiar feature of the electrode is the carbon snap that makes it radiolucent. Neither of the components contains any ferromagnetic materials, therefore the electrodes are fully compatible with MRI applications. The electrodes are MRI tested for use up to 3 T electro-magnetic field. The use of the electrodes do not affect the safety and functioning of Magnetic Resonance Imaging Systems. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids
Disposable ECG monitoring electrodes have features that make them abs
Disposable ECG monitoring electrodes have features that make them absolutely reliable during long monitoring ECG recording (not longer than 72 hours). F9053PRRM model are oval-shaped electrodes, 20x15mm dimensions, equipped with 35cm long wire and 4mm socket, pre-gelled and they can be easily connected to the ECG monitor, avoiding pressure on the skin. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids.F9053PRRM model is radiotranslucent, therefore it allows the user to perform radiographic procedures without removing the electrode.
Reusable praecordial suction chest electrodes for ECG, metallic part diameter Ø
Reusable praecordial suction chest electrodes for ECG, metallic part diameter Ø 30mm and ball diameter Ø 33mm. F9016SSC/RU model has features that make itabsolutely reliable during signal recording with all different ECG devices on the market. The metallic part is silver and silver chloride (Ag/AgCl) allowing a safe and clear signal transmission. FIAB suction chest electrodes, thanks to screw and clip connections, can be tapped to all ECG devices and monitors with patient cables which have plug or snap connections.
Reusable praecordial suction chest electrodes for ECG, metallic part Ø 20mm and
Reusable praecordial suction chest electrodes for ECG, metallic part Ø 20mm and ball diameter Ø 25mm. F9015SSC/RU model has features that make itabsolutely reliable during signal recording with all different ECG devices on the market. The metallic part is silver and silver chloride (Ag/AgCl) allowing a safe and clear signal transmission. FIAB suction chest electrodes, thanks to screw and clip connections, can be tapped to all ECG devices and monitors with patient cables which have plug or snap connections.
Reusable praecordial suction chest electrodes for ECG, metallic part Ø 24mm and
Reusable praecordial suction chest electrodes for ECG, metallic part Ø 24mm and ball diameter Ø 33mm. F9009SSC/RU model has features that make itabsolutely reliable during signal recording with all different ECG devices on the market. The metallic part is silver and silver chloride (Ag/AgCl) allowing a safe and clear signal transmission. FIAB suction chest electrodes, thanks to screw and clip connections, can be tapped to all ECG devices and monitors with patient cables which have plug or snap connections.
Reusable praecordial suction chest electrodes for ECG, metallic part Ø 15mm and
Reusable praecordial suction chest electrodes for ECG, metallic part Ø 15mm and ball diameter Ø 25mm. F9008SSC/RU model has features that make itabsolutely reliable during signal recording with all different ECG devices on the market. The metallic part is silver and silver chloride (Ag/AgCl) allowing a safe and clear signal transmission. FIAB suction chest electrodes, thanks to screw and clip connections, can be tapped to all ECG devices and monitors with patient cables which have plug or snap connections.
Reusable light electrodes for ECG, active surface 113 mm³ and cable len
Reusable light electrodes for ECG, active surface 113 mm³ and cable length 60 cm. F9027 model has features that make it absolutely reliable during signal recording with all different ECG on the market. Cable and metallic recording electrode are very light and can be easily positioned using conductive gel. ECG signal is extremely clear thanks to beryllium of which the electrode is made of. FIAB light electrodes can be tapped to all ECGs and monitors with Ø 4 mm snap cable
Disposable ECG monitoring electrodes have features that make them abs
Disposable ECG monitoring electrodes have features that make them absolutely reliable during long monitoring ECG recording (not longer than 72 hours). F9053PR/10 model is oval-shaped electrodes, 20x15mm dimensions, equipped with 10cm long wire and 4mm socket, pre-gelled and they can be easily connected to the ECG monitor, avoiding pressure on the skin. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids.
Disposable ECG monitoring electrodes have features that make them abs
Disposable ECG monitoring electrodes have features that make them absolutely reliable during long monitoring ECG recording (not longer than 72 hours). F9058PR model is oval-shaped electrodes, 20x15mm dimensions,pre-gelled, equipped with 50cm long wire with DIN 42802-1 1.5mm socket. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids.
Disposable ECG monitoring electrodes have features that make them abs
Disposable ECG monitoring electrodes have features that make them absolutely reliable during long monitoring ECG recording (not longer than 72 hours). F9058PR model is oval-shaped electrodes, 20x15mm dimensions,pre-gelled, equipped with 50cm long wire with DIN 42802-1 1.5mm socket. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids.
Disposable ECG monitoring electrodes have features that make them abs
Disposable ECG monitoring electrodes have features that make them absolutely reliable during long monitoring ECG recording (not longer than 72 hours). F9053N model are round-shaped electrodes, Ø 32mm, equipped with 10cm long wire and 4mm socket, pre-gelled and they can be easily connected to the ECG monitor, avoiding pressure on the skin. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids.
F9047/4FL model is ECG disposable pregelled electrode with liquid gel, 28x44mm
F9047/4FL model is ECG disposable pregelled electrode with liquid gel, 28x44mm dimension and equipped with 4mm plug connection. The ECG electrode have features that make them absolutely reliable during signal recording. F9047/4FL model is used also recording in stress test and for Holter monitoring. They are compatible with different ECG devices on the market. After opening, the pouch can be folded to ensure a better preservation of the electrodes that remain inside. The products are Latex-free.
Disposable ECG monitoring electrodes have features that make them abs
Disposable ECG monitoring electrodes have features that make them absolutely reliable during long monitoring ECG recording (not longer than 72 hours). F9053/10 model are round-shaped electrodes, Ø 32mm, equipped with 10 cm long wire and 4mm socket, pre-gelled and they can be easily connected to the ECG monitor, avoiding pressure on the skin. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids.
Disposable ECG monitoring electrodes have features that make them abs
Disposable ECG monitoring electrodes have features that make them absolutely reliable during long monitoring ECG recording (not longer than 72 hours). F9058N/60 model is oval-shaped electrodes, 30x23mm dimensions, pre-gelled, equipped with 60cm long wire and DIN 42802-1 1.5mm socket. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids.
Disposable ECG monitoring electrodes have features that make them abs
Disposable ECG monitoring electrodes have features that make them absolutely reliable during long monitoring ECG recording (not longer than 72 hours). F9058P/60 model is round-shaped electrodes, Ø 32mm,pre-gelled, equipped with 60cm long wire and DIN 42802-1 1.5mm socket. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids.
Disposable ECG monitoring electrodes have features that make them abs
Disposable ECG monitoring electrodes have features that make them absolutely reliable during long monitoring ECG recording (not longer than 72 hours). F9053RM/80 model is round-shaped electrodes, Ø 32mm, equipped with 80cm long wire and 4mm socket, pre-gelled and it can be easily connected to the ECG monitor, avoiding pressure on the skin. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids.F9053RM/80 is radiotranslucent, therefore it allows the user to perform radiographic procedures without removing the electrode.
Disposable ECG electrodes with liquid gel, oval-shaped 50x48mm dimensions,Silv
Disposable ECG electrodes with liquid gel, oval-shaped 50x48mm dimensions,Silver/Silver Chloride(SSC) sensor and stainless steel snap. F9067 model is suitable both for rest and stress or Holter ECG recording, with a direct application onto the skin. . The SSC sensor permits a reliable and stable recording. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids.
F9069PRM model is disposable ECG RADIOLUCENT electrode with solid gel, ov
F9069PRM model is disposable ECG RADIOLUCENT electrode with solid gel, oval-shaped 32x36mm, Silver/Silver Chloride (SSC) sensor and carbon snap.The SSC sensor permits a reliable and stable recording. The peculiar feature of the electrode is the carbon snap that makes it radiolucent. Neither of the components contains any ferromagnetic materials, therefore the electrodes are fully compatible with MRI applications. The electrodes are MRI tested for use up to 3 T electro-magnetic field. The use of the electrodes do not affect the safety and functioning of Magnetic Resonance Imaging Systems. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids
Disposable ECG electrodes, round-shaped Ø 40,Silver/Silver Chloride(SSC) senso
Disposable ECG electrodes, round-shaped Ø 40,Silver/Silver Chloride(SSC) sensor and stainless steel snap. F9060P model is suitable for rest, long term, stress or Holter ECG recording, with a direct application onto the skin. The SSC sensor permits a reliable and stable recording. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids
ECG disposable electrodes with solid gel and SSC sensor, round-shaped Ø 40mm, pr
ECG disposable electrodes with solid gel and SSC sensor, round-shaped Ø 40mm, pre-gelled and equipped with snap connection. F9070P model has features that make it absolutely reliable during signal recording with all different ECG on the market in stress tests and holter.