Other products from "BRACCO DIAGNOSTICS INC"
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 10815112021136 390302 390302 Protocol Colon Insuff Demo FCX Insufflator, Automatic Carbon-Dioxide For Endoscope 2 Protocol Colon Insufflator Demo Unit
2 10815112020900 900910 900910 Safticuff DL Airway FGD Catheter, Retention, Barium Enema With Bag 2 SaftiCuff DK
3 10815112020856 900402 900402 Y Connector FGD Catheter, Retention, Barium Enema With Bag 2 "Y" Connector with Tubing
4 10815112020177 390402 390402 Protocol Administration Set with Small Catheter and Retention Cuff CO2 Delivery Protocol Administration Set with Small Catheter and Retention Cuff CO2 Delivery System for Colon Insufflation FCX Insufflator, Automatic Carbon-Dioxide For Endoscope 2 Protocol Administration Set with Small Catheter and Retention Cuff
5 10815112020160 390401 390401 Protocol Administration Set With Flexi-Cuff Retention Tip CO2 Delivery System fo Protocol Administration Set With Flexi-Cuff Retention Tip CO2 Delivery System for Colon Insufflation FCX Insufflator, Automatic Carbon-Dioxide For Endoscope Protocol Administration Set With Flexi-Cuff Retention Tip
6 10815112021082 901403 901403 Enteroclysis Admin Kit EZK Catheter, Retention Type 2 Enteroclysis Admin Kit
7 10815112021075 901309 901309 Junior Flexi Tip FGD Catheter, Retention, Barium Enema With Bag Junior Flexi Tip Pediatric Enema Tip
8 10815112021051 901307 901307 Nipple Colostomy Tip FGD Catheter, Retention, Barium Enema With Bag 2 FLEXI-STOME Nipple Colostomy Tip
9 10815112021006 901302 901302 XL Flexi Tip FGD Catheter, Retention, Barium Enema With Bag XL Flexi Tip: Adult Enema Tip
10 10815112020993 901301 901301 Rounded Flexi Tip FGD Catheter, Retention, Barium Enema With Bag Rounded Flexi Tip Adult Enema Tip
11 10815112020825 900303 900303 Empty Snap Cap Bag FGD Catheter, Retention, Barium Enema With Bag 2 Enema Kit: Empty Enema Bag Delivery System
12 10815112020818 900302 900302 Empty Snap Cap Bag FGD Catheter, Retention, Barium Enema With Bag 2 Enema Kit: Empty Enema Bag Delivery System
13 10815112020771 600602 600602 Basic Biopsy Tray w/o Biopsy Needle OJT Aspiration Tray 1 PercuSet Basic Biopsy Tray
14 10815112020634 900303 900303 Empty Snap Cap Bag FGD Catheter, Retention, Barium Enema With Bag Enema Kit: Empty Enema Bag Delivery System
15 10815112020566 601004 601004 EZ Gel 5L MUI Media,Coupling,Ultrasound E-Z-GEL UltraSound Gel
16 10815112020535 601001 601001 EZ Gel 8oz MUI Media,Coupling,Ultrasound 2 E-Z-GEL UltraSound Gel
17 10815112020207 450002 450002 CT Enema Kit (Empty) FGD Catheter, Retention, Barium Enema With Bag 2 CT Enema Administration Kit: Enema Delivery System
18 10815112021129 600803 600803 PercuSet Arthrogram Tray OGJ Nerve Block Tray PercuSet Arthrogram Tray
19 10815112021044 901306 901306 Cone Colostomy Tip FGD Catheter, Retention, Barium Enema With Bag 2 FLEXI-STOME Cone Colostomy Tip
20 10815112021013 901303 901303 Infant Flexi Tip FGD Catheter, Retention, Barium Enema With Bag 24 Fr Infant Flexi Tip: Pediatric Enema Tip
21 10815112020979 901202 901202 Non latex Air Retention Tip FGD Catheter, Retention, Barium Enema With Bag Miller Enema Air Tip with Retention Cuff
22 10815112020870 900404 900404 Air Bulb Insufflator FGD Catheter, Retention, Barium Enema With Bag Blue Air Bulb Insufflator
23 10815112020863 900403 900403 Remote Air Insufflator FGD Catheter, Retention, Barium Enema With Bag Remote Blue Air Bulb Insufflator Air Insufflation of Colon
24 10815112020764 600601 600601 PercuSet Local Anesthesia Tray OGJ Nerve Block Tray PercuSet Local Anesthesia Tray
25 10815112020641 901306 901306 Cone Colostomy Tip FGD Catheter, Retention, Barium Enema With Bag 2 FLEXI-STOME Cone Colostomy Tip
26 10815112020139 390305 390305 Protocol Acccessory Cart FCX Insufflator, Automatic Carbon-Dioxide For Endoscope 2 Protocol Accessory Cart
27 10815112020115 005110 005110 US005110 I V Solution Transfer Kit FPA Set, Administration, Intravascular 2 Solution Transfer Device
28 30815112020843 900401 900401 Tubing Clamp (Green) FGD Catheter, Retention, Barium Enema With Bag Tubing Clamp: Fits Standard 5/16' Tubing
29 10815112020986 901203 901203 SXL w/Att. (Silicone Cuff) FGD Catheter, Retention, Barium Enema With Bag 2 Super XL Enema System
30 10815112020894 900909 900909 XL Miller Air Tip FGD Catheter, Retention, Barium Enema With Bag Flexi Air Tip XL
31 10815112020214 600001 600001 Fast Find Grid KPR System, X-Ray, Stationary Fast Find Grid: Disposable CT Biopsy Grid
32 10815112020122 390301 390301 Protocol Colon Insufflator FCX Insufflator, Automatic Carbon-Dioxide For Endoscope 2 Protocol Colon Insufflator
33 10815112020016 000475 000475 Large Bore Tubing Administration Set EYN Tray, Irrigation, Sterile Fluid Administration Set
34 30815112020188 390513 390513 DIN Connector FCX Insufflator, Automatic Carbon-Dioxide For Endoscope 2 DIN 477 High Pressure Hose for CO2
35 10815112020832 900304 900304 Empty Exacta l Bag FGD Catheter, Retention, Barium Enema With Bag EXACTA l Screw Cap Bag: Empty Enema Bag Delivery System
36 30815112020799 710603 710603 High Pressure Hose and Yoke FCX Insufflator, Automatic Carbon-Dioxide For Endoscope 2 High Pressure Hose and Yoke
37 10815112021020 901304 901304 Miller Air Tip FGD Catheter, Retention, Barium Enema With Bag Miller Enema Air Tip: Without Retention Cuff
38 10815112020962 901201 901201 Non latex Retention Enema Tip FGD Catheter, Retention, Barium Enema With Bag Miller Enema Air Tip with Non-Latex Retention Cuff
39 10815112020955 901101 901101 Barium Enema Ring FGD Catheter, Retention, Barium Enema With Bag 2 Enema Ring: Fluid Collection Device
40 10815112020917 900911 900911 Safticuff SL Airway FGD Catheter, Retention, Barium Enema With Bag 2 Safti Cuff
41 10815112020559 601003 601003 EZ Scan Pack MUI Media,Coupling,Ultrasound 2 E-Z-SCAN Low Viscosity UltraSound Gel
42 10815112020542 601002 601002 EZ Scan 8oz Tube MUI Media,Coupling,Ultrasound 2 E-Z-SCAN Low Viscosity UltraSound Gel
43 10815112020153 390309 390309 Protocol Touch Administration Set we/20fr. Tip FCX Insufflator, Automatic Carbon-Dioxide For Endoscope Protocol Touch Administration Set with Small Catheter and Retention Cuff
44 30815112021093 901501 901501 Enteroclysis Cath 13F w/Ball EZK Catheter, Retention Type 2 Enteroclysis Catheter 13Fx155cm
45 30815112020805 710604 710604 High Pressure DISS Hose FCX Insufflator, Automatic Carbon-Dioxide For Endoscope 2 High Pressure DISS Hose For CO2
46 30815112020782 710602 710602 Two Tank Shuttle Valve System FCX Insufflator, Automatic Carbon-Dioxide For Endoscope 2 Two Tank Shuttle Valve System
47 10815112020146 390308 390308 Protocol Touch Insufflator FCX Insufflator, Automatic Carbon-Dioxide For Endoscope 2 Protocol Touch Colon Insufflator
48 10815112021143 390307 390307 Protocol Touch Insufflator Demo FCX Insufflator, Automatic Carbon-Dioxide For Endoscope 2 Protocol Touch Colon Insufflator Demo Unit
49 10815112021068 901308 901308 18 Fr Pediatric Flexi Tip FGD Catheter, Retention, Barium Enema With Bag 18 French Pediatric Flexi Tip
50 10815112021037 901305 901305 14 Fr Pediatric Flexi Tip FGD Catheter, Retention, Barium Enema With Bag 14 French Pediatric Flexi Tip
Other products with the same Product Code "KPS"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 00195278592309 Legend OMNI GANTRY 24-30 INCL. ELECTRONICS ASSY Omni G E MEDICAL SYSTEMS ISRAEL LTD.
2 00195278454218 Legend OMNI GANTRY 24-30 INCL. ELECTRONICS ASSY Omni GE MEDICAL SYSTEMS, INC.
3 00195278421586 H3912AA 5875815-10 MyoSPECT GANTRY MyoSPECT G E MEDICAL SYSTEMS ISRAEL LTD.
4 00195278421579 H3912AB 5875815-20 MyoSPECT ES GANTRY MyoSPECT ES G E MEDICAL SYSTEMS ISRAEL LTD.
5 00195278118295 H3911AB STARGATE NM GANTRY FINAL StarGuide G E MEDICAL SYSTEMS ISRAEL LTD.
6 00195278098603 MI PET DMI Gen2 Image System Asm, No Detectors Installed, Common Weld Gantry, Manuf PET DMI Gen2 Image System Asm, No Detectors Installed, Common Weld Gantry, Manufacturing Make Discovery GE MEDICAL SYSTEMS, INC.
7 B133NEUROQ382112070 3.80.20210429.143255 NeuroQ™ has been developed to aid in the assessment of human brain scans through NeuroQ™ has been developed to aid in the assessment of human brain scans through quantification of mean pixel values lying within standardized regions of interest, and to provide quantified comparisons with brain scans derived from FDG-PET studies of defined groups having no identified neuropsychiatric disease or symptoms, i.e., asymptomatic controls (AC). The Program provides automated analysis of brain PET scans, with output that includes quantification of relative activity in 240 different brain regions, as well as measures of the magnitude and statistical significance with which activity in each region differs from mean activity values of brain regions in the AC database. The program can be used to compare activity in brain regions of individual scans between two studies from the same patient, between symmetric regions of interest within the brain PET study, and to perform an image fusion of the patients PET and CT data. The program can also be used to for assisting in the assessment of prognosis in patients undergoing dementia evaluation with respect to the likelihood of progression of symptomatic disease, to provide analysis of amyloid uptake levels in the brain, and to evaluate and to provide a quantitative analysis of uptake levels in basal ganglia structures of the brain. The program processes the studies automatically, however, user verification of output is required and manual processing capability is provided. NeuroQ SYNTERMED INCORPORATED
8 B133NEUROQ382104290 3.80.20210429.143255 NeuroQ™ has been developed to aid in the assessment of human brain scans through NeuroQ™ has been developed to aid in the assessment of human brain scans through quantification of mean pixel values lying within standardized regions of interest, and to provide quantified comparisons with brain scans derived from FDG-PET studies of defined groups having no identified neuropsychiatric disease or symptoms, i.e., asymptomatic controls (AC). The Program provides automated analysis of brain PET scans, with output that includes quantification of relative activity in 240 different brain regions, as well as measures of the magnitude and statistical significance with which activity in each region differs from mean activity values of brain regions in the AC database. The program can be used to compare activity in brain regions of individual scans between two studies from the same patient, between symmetric regions of interest within the brain PET study, and to perform an image fusion of the patients PET and CT data. The program can also be used to for assisting in the assessment of prognosis in patients undergoing dementia evaluation with respect to the likelihood of progression of symptomatic disease, to provide analysis of amyloid uptake levels in the brain, and to evaluate and to provide a quantitative analysis of uptake levels in basal ganglia structures of the brain. The program processes the studies automatically, however, user verification of output is required and manual processing capability is provided. NeuroQ SYNTERMED INCORPORATED
9 B133NEUROQ300 3.8 NeuroQ™ has been developed to aid in the assessment of human brain scans through NeuroQ™ has been developed to aid in the assessment of human brain scans through quantification of mean pixel values lying within standardized regions of interest, and to provide quantified comparisons with brain scans derived from FDG-PET studies of defined groups having no identified neuropsychiatric disease or symptoms, i.e., asymptomatic controls (AC). The Program provides automated analysis of brain PET scans, with output that includes quantification of relative activity in 240 different brain regions, as well as measures of the magnitude and statistical significance with which activity in each region differs from mean activity values of brain regions in the AC database. The program can be used to compare activity in brain regions of individual scans between two studies from the same patient, between symmetric regions of interest within the brain PET study, and to perform an image fusion of the patients PET and CT data. The program can also be used to for assisting in the assessment of prognosis in patients undergoing dementia evaluation with respect to the likelihood of progression of symptomatic disease, to provide analysis of amyloid uptake levels in the brain, and to evaluate and to provide a quantitative analysis of uptake levels in basal ganglia structures of the brain. The program processes the studies automatically, however, user verification of output is required and manual processing capability is provided. NeuroQ SYNTERMED INCORPORATED
10 B133NEUROQ1 3.75.20171019 NeuroQ™ has been developed to aid in the assessment of human brain scans through NeuroQ™ has been developed to aid in the assessment of human brain scans through quantification of mean pixel values lying within standardized regions of interest, and to provide quantified comparisons with brain scans derived from FDG-PET studies of defined groups having no identified neuropsychiatric disease or symptoms, i.e., asymptomatic controls (AC). The Program provides automated analysis of brain PET scans, with output that includes quantification of relative activity in 240 different brain regions, as well as measures of the magnitude and statistical significance with which activity in each region differs from mean activity values of brain regions in the AC database. The program can be used to compare activity in brain regions of individual scans between two studies from the same patient, between symmetric regions of interest within the brain PET study, and to perform an image fusion of the patients PET and CT data. The program can also be used to for assisting in the assessment of prognosis in patients undergoing dementia evaluation with respect to the likelihood of progression of symptomatic disease, to provide analysis of amyloid uptake levels in the brain, and to evaluate and to provide a quantitative analysis of uptake levels in basal ganglia structures of the brain. The program processes the studies automatically, however, user verification of output is required and manual processing capability is provided. NeuroQ SYNTERMED INCORPORATED
11 B133NEUROQ0 3.6.20131127 NeuroQ™ has been developed to aid in the assessment of human brain scans through NeuroQ™ has been developed to aid in the assessment of human brain scans through quantification of mean pixel values lying within standardized regions of interest, and to provide quantified comparisons with brain scans derived from FDG-PET studies of defined groups having no identified neuropsychiatric disease or symptoms, i.e., asymptomatic controls (AC). The Program provides automated analysis of brain PET scans, with output that includes quantification of relative activity in 240 different brain regions, as well as measures of the magnitude and statistical significance with which activity in each region differs from mean activity values of brain regions in the AC database. The program can be used to compare activity in brain regions of individual scans between two studies from the same patient, between symmetric regions of interest within the brain PET study, and to perform an image fusion of the patients PET and CT data. The program can also be used to for assisting in the assessment of prognosis in patients undergoing dementia evaluation with respect to the likelihood of progression of symptomatic disease, to provide analysis of amyloid uptake levels in the brain, and to evaluate and to provide a quantitative analysis of uptake levels in basal ganglia structures of the brain. The program processes the studies automatically, however, user verification of output is required and manual processing capability is provided. NeuroQ SYNTERMED INCORPORATED
12 B133ECTB422112080 4.27720.29473 The Emory Cardiac Toolbox™ 4.0 is used to display gated wall motion and for quan The Emory Cardiac Toolbox™ 4.0 is used to display gated wall motion and for quantifying parameters of left-ventricular perfusion and function from gated SPECT & PET myocardial perfusion studies and for the evaluation of dynamic PET studies. These parameters are: perfusion, ejection fraction, end-diastolic volume, end-systolic volume, myocardial mass, transient ischemic dilatation (TID), analysis of coronary blood flow and coronary flow reserve, and assessment of cardiac mechanic dyssynchrony. In addition, the program offers the capability of providing the following diagnostic information: computer assisted visual scoring, prognostic information, and expert system image interpretation. The program can also be used for the 3D alignment of coronary artery models from CT coronary angiography onto the left ventricular 3D epicardial surface and for generation of the short axis, vertical, and horizontal long axis tomograms from the SPECT raw data using either filtered backprojection (FBP) or iterative reconstruction (MLEM/OSEM). The Emory Cardiac Toolbox can be used with any of the following Myocardial SPECT Protocols: Same Day and Two Day Sestamibi, Dual-Isotope (Tc-99m/Tl-201), Tetrofosmin, and Thallium, Rubidium-82, Rubidium-82 with CT-based attenuation correction, N-13-ammonia, FDG protocols, and user defined normal databases. This program was developed to run in the .NET operating system environment which can be executed on any PC, any nuclear medicine computer system, or through a web browser. In addition, the program can be used for the decision support in interpretation and automatic structured reporting of the study. The program processes the studies automatically, however, user verification of output is required and manual processing capability is provided. Emory Cardiac Toolbox SYNTERMED INCORPORATED
13 B133ECTB422102190 4.27720.29473 The Emory Cardiac Toolbox™ 4.0 is used to display gated wall motion and for quan The Emory Cardiac Toolbox™ 4.0 is used to display gated wall motion and for quantifying parameters of left-ventricular perfusion and function from gated SPECT & PET myocardial perfusion studies and for the evaluation of dynamic PET studies. These parameters are: perfusion, ejection fraction, end-diastolic volume, end-systolic volume, myocardial mass, transient ischemic dilatation (TID), analysis of coronary blood flow and coronary flow reserve, and assessment of cardiac mechanic dyssynchrony. In addition, the program offers the capability of providing the following diagnostic information: computer assisted visual scoring, prognostic information, and expert system image interpretation. The program can also be used for the 3D alignment of coronary artery models from CT coronary angiography onto the left ventricular 3D epicardial surface and for generation of the short axis, vertical, and horizontal long axis tomograms from the SPECT raw data using either filtered backprojection (FBP) or iterative reconstruction (MLEM/OSEM). The Emory Cardiac Toolbox can be used with any of the following Myocardial SPECT Protocols: Same Day and Two Day Sestamibi, Dual-Isotope (Tc-99m/Tl-201), Tetrofosmin, and Thallium, Rubidium-82, Rubidium-82 with CT-based attenuation correction, N-13-ammonia, FDG protocols, and user defined normal databases. This program was developed to run in the .NET operating system environment which can be executed on any PC, any nuclear medicine computer system, or through a web browser. In addition, the program can be used for the decision support in interpretation and automatic structured reporting of the study. The program processes the studies automatically, however, user verification of output is required and manual processing capability is provided. Emory Cardiac Toolbox SYNTERMED INCORPORATED
14 B133ECTB422009110 4.2.7559.13747 The Emory Cardiac Toolbox™ 4.0 is used to display gated wall motion and for quan The Emory Cardiac Toolbox™ 4.0 is used to display gated wall motion and for quantifying parameters of left-ventricular perfusion and function from gated SPECT & PET myocardial perfusion studies and for the evaluation of dynamic PET studies. These parameters are: perfusion, ejection fraction, end-diastolic volume, end-systolic volume, myocardial mass, transient ischemic dilatation (TID), analysis of coronary blood flow and coronary flow reserve, and assessment of cardiac mechanic dyssynchrony. In addition, the program offers the capability of providing the following diagnostic information: computer assisted visual scoring, prognostic information, and expert system image interpretation. The program can also be used for the 3D alignment of coronary artery models from CT coronary angiography onto the left ventricular 3D epicardial surface and for generation of the short axis, vertical, and horizontal long axis tomograms from the SPECT raw data using either filtered backprojection (FBP) or iterative reconstruction (MLEM/OSEM). The Emory Cardiac Toolbox can be used with any of the following Myocardial SPECT Protocols: Same Day and Two Day Sestamibi, Dual-Isotope (Tc-99m/Tl-201), Tetrofosmin, and Thallium, Rubidium-82, Rubidium-82 with CT-based attenuation correction, N-13-ammonia, FDG protocols, and user defined normal databases. This program was developed to run in the .NET operating system environment which can be executed on any PC, any nuclear medicine computer system, or through a web browser. In addition, the program can be used for the decision support in interpretation and automatic structured reporting of the study. The program processes the studies automatically, however, user verification of output is required and manual processing capability is provided. Emory Cardiac Toolbox SYNTERMED INCORPORATED
15 B133ECTB400 4.2.7003.28586 The Emory Cardiac Toolbox™ 4.0 is used to display gated wall motion and for quan The Emory Cardiac Toolbox™ 4.0 is used to display gated wall motion and for quantifying parameters of left-ventricular perfusion and function from gated SPECT & PET myocardial perfusion studies and for the evaluation of dynamic PET studies. These parameters are: perfusion, ejection fraction, end-diastolic volume, end-systolic volume, myocardial mass, transient ischemic dilatation (TID), analysis of coronary blood flow and coronary flow reserve, and assessment of cardiac mechanic dyssynchrony. In addition, the program offers the capability of providing the following diagnostic information: computer assisted visual scoring, prognostic information, and expert system image interpretation. The program can also be used for the 3D alignment of coronary artery models from CT coronary angiography onto the left ventricular 3D epicardial surface and for generation of the short axis, vertical, and horizontal long axis tomograms from the SPECT raw data using either filtered backprojection (FBP) or iterative reconstruction (MLEM/OSEM). The Emory Cardiac Toolbox can be used with any of the following Myocardial SPECT Protocols: Same Day and Two Day Sestamibi, Dual-Isotope (Tc-99m/Tl-201), Tetrofosmin, and Thallium, Rubidium-82, Rubidium-82 with CT-based attenuation correction, N-13-ammonia, FDG protocols, and user defined normal databases. This program was developed to run in the .NET operating system environment which can be executed on any PC, any nuclear medicine computer system, or through a web browser. In addition, the program can be used for the decision support in interpretation and automatic structured reporting of the study. The program processes the studies automatically, however, user verification of output is required and manual processing capability is provided. Emory Cardiac Toolbox SYNTERMED INCORPORATED
16 B133ECTB40 4.0.5121.18001 The Emory Cardiac Toolbox™ 4.0 is used to display gated wall motion and for quan The Emory Cardiac Toolbox™ 4.0 is used to display gated wall motion and for quantifying parameters of left-ventricular perfusion and function from gated SPECT & PET myocardial perfusion studies and for the evaluation of dynamic PET studies. These parameters are: perfusion, ejection fraction, end-diastolic volume, end-systolic volume, myocardial mass, transient ischemic dilatation (TID), analysis of coronary blood flow and coronary flow reserve, and assessment of cardiac mechanic dyssynchrony. In addition, the program offers the capability of providing the following diagnostic information: computer assisted visual scoring, prognostic information, and expert system image interpretation. The program can also be used for the 3D alignment of coronary artery models from CT coronary angiography onto the left ventricular 3D epicardial surface and for generation of the short axis, vertical, and horizontal long axis tomograms from the SPECT raw data using either filtered backprojection (FBP) or iterative reconstruction (MLEM/OSEM). The Emory Cardiac Toolbox can be used with any of the following Myocardial SPECT Protocols: Same Day and Two Day Sestamibi, Dual-Isotope (Tc-99m/Tl-201), Tetrofosmin, and Thallium, Rubidium-82, Rubidium-82 with CT-based attenuation correction, N-13-ammonia, FDG protocols, and user defined normal databases. This program was developed to run in the .NET operating system environment which can be executed on any PC, any nuclear medicine computer system, or through a web browser. In addition, the program can be used for the decision support in interpretation and automatic structured reporting of the study. The program processes the studies automatically, however, user verification of output is required and manual processing capability is provided. Emory Cardiac Toolbox SYNTERMED INCORPORATED
17 30815112020584 1.00 001771 Cardiac PET Processing Software HeartSee Cardiac PET Processing Software BRACCO DIAGNOSTICS INC
18 10841962118726 10841962118726 RT-B889KYCF2A Encompass™ Fibreplast® Variable Perf Open View Anterior Only Encompass™ SRS Fibreplast® Anterior Mask QFIX
19 10841962111406 RT-B889KYCF RT-B889KYCF Encompass Head Only Open View Thermoplastic System Encompass™ SRS Fibreplast™ System QFIX
20 10841962111390 RT-B889KYCF2 RT-B889KYCF2 Encompass Fibreplast Variable Perf Open View Mask System Encompass™ SRS Fibreplast™ System QFIX
21 10841962111277 RT-5100-05 RT-5100-05 Lithotomy AirShuttle™ Lithotomy AirShuttle™ QFIX
22 10841962111260 RT-5100-04 RT-5100-04 BoS™ AirShuttle™ BoS™ AirShuttle™ QFIX
23 10841962111253 RT-5100-02 RT-5100-02 Portrait™ AirShuttle™ Portrait™ AirShuttle™ QFIX
24 10841962111246 RT-5100-01 RT-5100-01 Slate AirShuttle™ Slate AirShuttle™ QFIX
25 10841962111239 RT-5100 RT-5100 AirDrive Trolley™ AirDrive Trolley™ QFIX
26 10841962111123 RT-4558CB03 RT-4558CB03 ZiFix Traverse™ Abdominal/Thoracic Motion Control System ZiFix Traverse™ QFIX
27 10841962110980 RT-4800-B2 RT-4800-B2 InfinityLock™ SBRT Compression Bridge, Large InfinityLock™ QFIX
28 10841962110973 RT-4800-B1 RT-4800-B1 InfinityLock™ SBRT Compression Bridge, Small InfinityLock™ QFIX
29 10841962110966 RT-4800-01 RT-4800-01 Alta™ Multipurpose Device Alta™ QFIX
30 10841962110928 10841962110928 RT-B889KYCF2A Encompass™ Fibreplast® Variable Perf Open View Anterior Only Encompass™ SRS Fibreplast™ Anterior Mask QFIX
31 10841962110775 RT-4600-03-MRI RT-4600-03-MRI SRS MR Adapter for Portrait™ and S-Type Devices SRS MR Adapter QFIX
32 10841962110768 RT-4600-03 RT-4600-03 SRS Adapter for Portrait™ and S-Type Devices SRS Adapter QFIX
33 10841962110713 RT-5100-06 RT-5100-06 Symphony™ Brachytherapy Transfer Device with Cutout Symphony™ QFIX
34 10841962110706 RT-5100-05 RT-5100-05 Symphony™ Brachytherapy Transfer Device Symphony™ QFIX
35 10841962110508 RT-4558CB02 RT-4558CB02 ZiFix™ Abdominal/Thoracic Motion Control System ZiFix™ QFIX
36 10841962110447 RT-5100-04 RT-5100-04 Symphony™ Bos™ Transfer Device Symphony™ BoS™ QFIX
37 10841962109564 RT-5100-03 RT-5100-03 Symphony Brachytherapy Transfer Device Symphony™ QFIX
38 10841962109557 RT-5100-02 RT-5100-02 Symphony Portrait Head/Neck Transfer Device Symphony™ Portrait™ QFIX
39 10841962109540 RT-5100-01 RT-5100-01 Symphony Standard Transfer Device Symphony™ QFIX
40 10841962109533 RT-5100 RT-5100 Symphony™ Patient Trolley Symphony™ QFIX
41 10841962109526 RT-B889KYCF RT-B889KYCF Encompass Head Only Open View Thermoplastic System Encompass™ SRS Fibreplast™ System QFIX
42 10841962109519 RT-B889KYCF2 RT-B889KYCF2 Encompass Fibreplast Variable Perf Open View Mask System Encompass™ SRS Fibreplast™ System QFIX
43 10841962109502 RT-4600KV-01 RT-4600KV-01 kVue Encompass SRS Insert with E0 headrest & hand grip array Encompass™ QFIX
44 10841962109496 RT-4600-01-MRI RT-4600-01-MRI Encompass SRS MRI Standalone Device with E0 headrest & hand grip array Encompass™ QFIX
45 10841962109489 RT-4600-01 RT-4600-01 Encompass SRS Stand Alone Device with E0 headrest & hand grip array Encompass™ QFIX
46 10840682142875 690 VCT Boost Upgrade Discovery PET CT GE MEDICAL SYSTEMS, INC.
47 08500314551332 133 0133 The Radialis PET Camera (or Radialis PET Imager) is a high spatial resolution, s The Radialis PET Camera (or Radialis PET Imager) is a high spatial resolution, small field-of-view PET imaging camera specifically developed for close-range, organ-targeted (i.e., limited field) imaging. The Radialis PET Camera is a partial-ring planar PET camera, equipped with lutetium-containing gamma-ray detectors, which collect gamma rays emitted by injected positron-emitting radiopharmaceuticals, and generates images corresponding to the relative concentrations of these radiopharmaceuticals in the body. The Radialis PET Camera is designed to collect gamma rays emitted by the injected radiopharmaceutical in a patient’s body part with high efficiency. RADIALIS PET CAMERA RADIALIS INC
48 08437018413041 MAMMI DR FP-0203 MAMMI is a Positron Emission Tomography (PET) system for medical imaging applica MAMMI is a Positron Emission Tomography (PET) system for medical imaging applications and for measuring the distribution of positron-emitting radiodrugs administered to patients to detect breast cancer. The system MAMMI presents two modalities:- Breast PET Mammography System with a single ring detector and a prone examination bed.- Breast PET Mammography System with a double ring detector and a prone examination bed (this record). MAMMI GENERAL EQUIPMENT FOR MEDICAL IMAGING SA
49 08437018413034 MAMMI SR FP-0202 MAMMI is a Positron Emission Tomography (PET) system for medical imaging applica MAMMI is a Positron Emission Tomography (PET) system for medical imaging applications and for measuring the distribution of positron-emitting radiodrugs administered to patients to detect breast cancer. The system MAMMI presents two modalities:- Breast PET Mammography System with a single ring (SR) detector and a prone examination bed (this record).- Breast PET Mammography System with a double ring (DR) detector and a prone examination bed. MAMMI GENERAL EQUIPMENT FOR MEDICAL IMAGING SA
50 07290108670158 D-SPECT 004 8010013-01 Single Photon Emission Computed Tomography system D-SPECT Refurbished SPECTRUM DYNAMICS MEDICAL, INC