CareEvent is a distributed alarming solution. With CareEvent the Philips Alarm d
CareEvent is a distributed alarming solution. With CareEvent the Philips Alarm distribution solution includes rules and escalation levels to deliver the right alarm to the right caregiver with the right information on a mobile device.
MSX
System, network and communication, physiological monitors
"SureSigns Central Monitoring System for connectivity to SureSigns VM patient mo
"SureSigns Central Monitoring System for connectivity to SureSigns VM patient monitors, single or dual display support Includes PC with software installed, SW CD, license key, speakers, mouse, keyboard optional :printer, switch"
MHX
MONITOR, PHYSIOLOGICAL, PATIENT(WITH ARRHYTHMIA DETECTION OR ALARMS)
Radiolucent Neonatal Cloth Monitoring Electrodes w/Preattached Lead wires (IEC v
Radiolucent Neonatal Cloth Monitoring Electrodes w/Preattached Lead wires (IEC version colors lead wires)
Radiolucent Neonatal Cloth Monitoring Electrodes w/Preattached Lead wires (IEC v
Radiolucent Neonatal Cloth Monitoring Electrodes w/Preattached Lead wires (IEC version colors lead wires)
Reusable peripheral electrodes for ECG, 31.5x22mm dimensions, have features that
Reusable peripheral electrodes for ECG, 31.5x22mm dimensions, have features that make them absolutely reliable during signal recording with all different ECG recorders on the market. The metallic part is silver coated (Ag/AgCl) allowing a safe and clear signal transmission. F9010SSC-6 thanks to screw and snap connections, can be tapped to all ECG recorders and monitors both with plug and snap. To be used with fasten belts.The product is Latex-free and Nickel-free.
Disposable ECG RADIOLUCENT electrodes with liquid gel, 32x44mm dimensions, Silve
Disposable ECG RADIOLUCENT electrodes with liquid gel, 32x44mm dimensions, Silver/Silver Chloride (SSC) sensor and carbon snap. F9047RM model is suitable both for rest and stress or Holter ECG recording, with a direct application onto the skin.The SSC sensor permits a reliable and stable recording. The peculiar feature of the electrode is the carbon snap that makes it radiolucent. Neither of the components contains any ferromagnetic materials, therefore the electrodes are fully compatible with MRI applications. The electrodes are MRI tested for use up to 3 T electro-magnetic field. The use of the electrodes do not affect the safety and functioning of Magnetic Resonance Imaging Systems. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids
Disposable ECG RADIOLUCENT electrodes with solid gel, 28x44mm dimensions, Silver
Disposable ECG RADIOLUCENT electrodes with solid gel, 28x44mm dimensions, Silver/Silver Chloride(SSC) sensor and carbon snap. F9046RM model is suitable both for rest and stress or Holter ECG recording, with a direct application onto the skin. The SSC sensor permits a reliable and stable recording. The peculiar feature of the electrode is the carbon snap that makes it radiolucent. Neither of the components contains any ferromagnetic materials, therefore the electrodes are fully compatible with MRI applications. The electrodes are MRI tested for use up to 3 T electro-magnetic field. The use of the electrodes do not affect the safety and functioning of Magnetic Resonance Imaging Systems. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids
Disposable ECG electrodes, oval-shaped 50x48mm dimensions,Silver/Silver Chlori
Disposable ECG electrodes, oval-shaped 50x48mm dimensions,Silver/Silver Chloride(SSC) sensor and stainless steel snap. F9060 model is suitable for rest, long term, stress or Holter ECG recording, with a direct application onto the skin. The SSC sensor permits a reliable and stable recording. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids
Disposable ECG electrodes with solid gel, 28x44mm dimensions,Silver/Silver Chlo
Disposable ECG electrodes with solid gel, 28x44mm dimensions,Silver/Silver Chloride(SSC) sensor and stainless steel snap. F9046 model is suitable both for rest and stress or Holter ECG recording, with a direct application onto the skin. The SSC sensor permits a reliable and stable recording. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids.
Disposable oval-shaped ECG electrodes with liquid gel, Silver/Silver Chlor
Disposable oval-shaped ECG electrodes with liquid gel, Silver/Silver Chloride(SSC) sensor, 52x32mm dimensions and with 4mm socket . These electrodes dimensions have features that make them absolutely reliable during signal recording in rest tests, with a direct application onto the skin. The SSC sensor permits a reliable and stable recording and off-centered configuration allows a better quality of ECG signal and reduces artifacts. They comply with ANSI/AAMI EC12:2000 permitting the signal recovery after defibrillator discharge. After opening, the pouch can be folded to ensure a better preservation of the electrodes that remain inside. The products are latex-free.
Disposable round-shaped ECG electrodes with liquid gel, Ø 42mm, Silver/Sil
Disposable round-shaped ECG electrodes with liquid gel, Ø 42mm, Silver/Silver Chloride(SSC) sensor and metal snap. These electrodes are suitable for short and medium term monitoring, stress ECG recording and Holter, with a direct application onto the skin. The SSC sensor permits a reliable and stable recording and off-centered configuration allows a better quality of ECG signal and reduces artifacts.
Disposable round-shaped ECG electrodes with liquid gel, Ø 50mm, Silver/Sil
Disposable round-shaped ECG electrodes with liquid gel, Ø 50mm, Silver/Silver Chloride(SSC) sensor and metal snap. These electrodes are suitable for short and medium term monitoring, stress ECG recording and Holter, with a direct application onto the skin. The SSC sensor permits a reliable and stable recording and off-centered configuration allows a better quality of ECG signal and reduces artifacts.
Disposable round-shaped ECG electrodes with liquid gel, Ø 60mm, Silver/Sil
Disposable round-shaped ECG electrodes with liquid gel, Ø 60mm, Silver/Silver Chloride(SSC) sensor and metal snap. These electrodes are suitable for short and medium term monitoring, stress ECG recording and Holter, with a direct application onto the skin. The SSC sensor permits a reliable and stable recording and off-centered configuration allows a better quality of ECG signal and reduces artifacts.
F9057PRRM model is a disposable round-shaped ECG monitoring electrodes have feat
F9057PRRM model is a disposable round-shaped ECG monitoring electrodes have features that make them absolutely reliable during long monitoring ECG recording (not longer than 72 hours). F9057PRRM is pre-gelled, Ø 32mm, equipped with 50cm long wire and DIN 42802-1 1.5mm socket. The external surface is made of non woven fabric. The fabric is made of plastic polyethylene fiber (and not natural fiber) that guarantees the transpiration of the skin, but at the same time the resistance to liquids with which they may come into contact during their use. Neonatal and Premature model.F9057PRRM model is radiotranslucent, therefore it allows the user to perform radiographic procedures without removing the electrode.
F9057PR model is a disposable oval-shaped ECG monitoring electrodes have feature
F9057PR model is a disposable oval-shaped ECG monitoring electrodes have features that make them absolutely reliable during long monitoring ECG recording (not longer than 72 hours). F9057PR is pre-gelled, 20x15mm dimensions, equipped with 50cm long wire and DIN 42802-1 1.5mm socket. The external surface is made of non woven fabric. The fabric is made of plastic polyethylene fiber (and not natural fiber) that guarantees the transpiration of the skin, but at the same time the resistance to liquids with which they may come into contact during their use. Neonatal and premature model.
F9057NRM model is a disposable oval-shaped ECG monitoring electrodes have featur
F9057NRM model is a disposable oval-shaped ECG monitoring electrodes have features that make them absolutely reliable during long monitoring ECG recording (not longer than 72 hours). F9057NRM is pre-gelled, 23x30mm dimensions, equipped with 50cm long wire and DIN 42802-1 1.5mm socket. The external surface is made of non woven fabric. The fabric is made of plastic polyethylene fiber (and not natural fiber) that guarantees the transpiration of the skin, but at the same time the resistance to liquids with which they may come into contact during their use. Pediatric and Neonatal model.F9057NRM model is radiotranslucent, therefore it allows the user to perform radiographic procedures without removing the electrode.
F9057N model is a disposable oval-shaped ECG monitoring electrodes have features
F9057N model is a disposable oval-shaped ECG monitoring electrodes have features that make them absolutely reliable during long monitoring ECG recording (not longer than 72 hours). F9057N is pre-gelled, 23x30mm dimensions, equipped with 50cm long wire and DIN 42802-1 1.5mm socket. The external surface is made of non woven fabric. The fabric is made of plastic polyethylene fiber (and not natural fiber) that guarantees the transpiration of the skin, but at the same time the resistance to liquids with which they may come into contact during their use.Pediatric and Neonatal model.
F9057PRM model is a disposable round-shaped ECG monitoring electrodes have featu
F9057PRM model is a disposable round-shaped ECG monitoring electrodes have features that make them absolutely reliable during long monitoring ECG recording (not longer than 72 hours). F9057PRM is pre-gelled, Ø 32mm, equipped with 50cm long wire and DIN 42802-1 1.5mm socket. The external surface is made of non woven fabric. The fabric is made of plastic polyethylene fiber (and not natural fiber) that guarantees the transpiration of the skin, but at the same time the resistance to liquids with which they may come into contact during their use. Adult and Pediatric model.F9057PRM model is radiotranslucent, therefore it allows the user to perform radiographic procedures without removing the electrode.