No | Primary DI | Version or Model | Catalog Number | Device Description | Product Code | Product Code Name | Device Class | Brand Name |
---|---|---|---|---|---|---|---|---|
1 | 00814321020452 | FloPump/FloProbe Kit (Non-Sterile) | 6000N(KIT) | The IBC FloPump is a single-use, disposable centrifugal blood pump intended for The IBC FloPump is a single-use, disposable centrifugal blood pump intended for use only with the Medtronic Bio Medicus Bio-Console to pump blood through the extracorporeal bypass circuit during open heart surgery. | KFM | Pump, Blood, Cardiopulmonary Bypass, Non-Roller Type | 2 | FloPump |
2 | 00814321020445 | 6500N | 6500N | The FloPump 57mL Centrifugal Pump is a device that uses a method other than revo The FloPump 57mL Centrifugal Pump is a device that uses a method other than revolving rollers to pump the blood through an extracorporeal circuit for periods lasting less than 6 hours for the purpose of providing either:i) Full or partial cardiopulmonary bypass (i.e., circuit includes an oxygenator) during open surgical procedures on the heart or great vessels; orii) Temporary circulatory bypass for diversion offlow around a planned disruption of the circulatory pathway necessary for open surgical procedures on the aorta or vena cava. | KFM | Pump, Blood, Cardiopulmonary Bypass, Non-Roller Type | 2 | FloPump |
3 | 00814321020117 | 1/4" FloPump (Sterile) | 6300S | The IBC FloPump is a single-use, disposable centrifugal blood pump intended for The IBC FloPump is a single-use, disposable centrifugal blood pump intended for use only with the Medtronic Bio Medicus Bio-Console to pump blood through the extracorporeal bypass circuit during open heart surgery. | KFM | Pump, Blood, Cardiopulmonary Bypass, Non-Roller Type | 2 | FloPump |
4 | 00814321020438 | 6500S | 6500S | The FloPump 57mL Centrifugal Pump is a device that uses a method other than revo The FloPump 57mL Centrifugal Pump is a device that uses a method other than revolving rollers to pump the blood through an extracorporeal circuit for periods lasting less than 6 hours for the purpose of providing either: i) Full or partial cardiopulmonary bypass (i.e., circuit includes an oxygenator) during open surgical procedures on the heart or great vessels; or ii) Temporary circulatory bypass for diversion offlow around a planned disruption of the circulatory pathway necessary for open surgical procedures on the aorta or vena cava. | KFM | Pump, Blood, Cardiopulmonary Bypass, Non-Roller Type | 2 | FloPump |
5 | 00814321020148 | 6400N | 6400N | The FloPump 32mL Centrifugal Pump is a device that uses a method other than revo The FloPump 32mL Centrifugal Pump is a device that uses a method other than revolving rollers to pump the blood through an extracorporeal circuit for periods lasting less than 6 hours for the purpose of providing either:i) Full or partial cardiopulmonary bypass (i.e., circuit includes an oxygenator) during open surgical procedures on the heart or great vessels; orii) Temporary circulatory bypass for diversion offlow around a planned disruption of the circulatory pathway necessary for open surgical procedures on the aorta or vena cava. | KFM | Pump, Blood, Cardiopulmonary Bypass, Non-Roller Type | 2 | FloPump |
6 | 00814321020131 | 6400S | 6400S | The FloPump 32mL Centrifugal Pump is a device that uses a method other than revo The FloPump 32mL Centrifugal Pump is a device that uses a method other than revolving rollers to pump the blood through an extracorporeal circuit for periods lasting less than 6 hours for the purpose of providing either: i) Full or partial cardiopulmonary bypass (i.e., circuit includes an oxygenator) during open surgical procedures on the heart or great vessels; or ii) Temporary circulatory bypass for diversion offlow around a planned disruption of the circulatory pathway necessary for open surgical procedures on the aorta or vena cava. | KFM | Pump, Blood, Cardiopulmonary Bypass, Non-Roller Type | 2 | FloPump |
7 | 00814321020124 | 1/4" FloPump (Non-Sterile) | 6300N | The IBC FloPump is a single-use, disposable centrifugal blood pump intended for The IBC FloPump is a single-use, disposable centrifugal blood pump intended for use only with the Medtronic Bio Medicus Bio-Console to pump blood through the extracorporeal bypass circuit during open heart surgery. | KFM | Pump, Blood, Cardiopulmonary Bypass, Non-Roller Type | 2 | FloPump |
8 | 00814321020100 | 1/4" FloPump/FloProbe Kit (Sterile) | 6300S(KIT) | The IBC FloPump is a single-use, disposable centrifugal blood pump intended for The IBC FloPump is a single-use, disposable centrifugal blood pump intended for use only with the Medtronic Bio Medicus Bio-Console to pump blood through the extracorporeal bypass circuit during open heart surgery. | KFM | Pump, Blood, Cardiopulmonary Bypass, Non-Roller Type | 2 | FloPump |
9 | 00814321020094 | FloPump/FloProbe Kit (Sterile) | 6000S(KIT) | The IBC FloPump is a single-use, disposable centrifugal blood pump intended for The IBC FloPump is a single-use, disposable centrifugal blood pump intended for use only with the Medtronic Bio Medicus Bio-Console to pump blood through the extracorporeal bypass circuit during open heart surgery. | KFM | Pump, Blood, Cardiopulmonary Bypass, Non-Roller Type | 2 | FloPump |
10 | 00814321020087 | 8300XXL | The AffloVest is comprised of a vest of synthetic polymer fabric with oscillatin The AffloVest is comprised of a vest of synthetic polymer fabric with oscillating vibratory motorsorganized into zones. The vest may be run on battery or A/C power from a standard wall outlet.The AffloVest is intended for promoting airway clearance and improvement of bronchialdrainage by enhancing mobilization of bronchial secretions where external manipulation of thethorax is the physician’s choice of treatment. | BYI | Percussor, Powered-Electric | 2 | AffloVest | |
11 | 00814321020070 | 8300XL | The AffloVest is comprised of a vest of synthetic polymer fabric with oscillatin The AffloVest is comprised of a vest of synthetic polymer fabric with oscillating vibratory motorsorganized into zones. The vest may be run on battery or A/C power from a standard wall outlet.The AffloVest is intended for promoting airway clearance and improvement of bronchialdrainage by enhancing mobilization of bronchial secretions where external manipulation of thethorax is the physician’s choice of treatment. | BYI | Percussor, Powered-Electric | 2 | AffloVest | |
12 | 00814321020063 | 8300 | The AffloVest is comprised of a vest of synthetic polymer fabric with oscillatin The AffloVest is comprised of a vest of synthetic polymer fabric with oscillating vibratory motorsorganized into zones. The vest may be run on battery or A/C power from a standard wall outlet.The AffloVest is intended for promoting airway clearance and improvement of bronchialdrainage by enhancing mobilization of bronchial secretions where external manipulation of thethorax is the physician’s choice of treatment. | BYI | Percussor, Powered-Electric | 2 | AffloVest | |
13 | 00814321020056 | 8200 | The AffloVest is comprised of a vest of synthetic polymer fabric with oscillatin The AffloVest is comprised of a vest of synthetic polymer fabric with oscillating vibratory motorsorganized into zones. The vest may be run on battery or A/C power from a standard wall outlet.The AffloVest is intended for promoting airway clearance and improvement of bronchialdrainage by enhancing mobilization of bronchial secretions where external manipulation of thethorax is the physician’s choice of treatment. | BYI | Percussor, Powered-Electric | 2 | AffloVest | |
14 | 00814321020049 | 8100XXS | The AffloVest is comprised of a vest of synthetic polymer fabric with oscillatin The AffloVest is comprised of a vest of synthetic polymer fabric with oscillating vibratory motorsorganized into zones. The vest may be run on battery or A/C power from a standard wall outlet.The AffloVest is intended for promoting airway clearance and improvement of bronchialdrainage by enhancing mobilization of bronchial secretions where external manipulation of thethorax is the physician’s choice of treatment. | BYI | Percussor, Powered-Electric | 2 | AffloVest | |
15 | 00814321020032 | 8100XS | The AffloVest is comprised of a vest of synthetic polymer fabric with oscillatin The AffloVest is comprised of a vest of synthetic polymer fabric with oscillating vibratory motorsorganized into zones. The vest may be run on battery or A/C power from a standard wall outlet.The AffloVest is intended for promoting airway clearance and improvement of bronchialdrainage by enhancing mobilization of bronchial secretions where external manipulation of thethorax is the physician’s choice of treatment. | BYI | Percussor, Powered-Electric | 2 | AffloVest | |
16 | 00814321020025 | 8100 | The AffloVest is comprised of a vest of synthetic polymer fabric with oscillatin The AffloVest is comprised of a vest of synthetic polymer fabric with oscillating vibratory motorsorganized into zones. The vest may be run on battery or A/C power from a standard wall outlet.The AffloVest is intended for promoting airway clearance and improvement of bronchialdrainage by enhancing mobilization of bronchial secretions where external manipulation of thethorax is the physician’s choice of treatment. | BYI | Percussor, Powered-Electric | 2 | AffloVest | |
17 | 00814321020018 | FloPump (Sterile) | 6000S | The IBC FloPump is a single-use, disposable centrifugal blood pump intended for The IBC FloPump is a single-use, disposable centrifugal blood pump intended for use only with the Medtronic Bio Medicus Bio-Console to pump blood through the extracorporeal bypass circuit during open heart surgery. | KFM | Pump, Blood, Cardiopulmonary Bypass, Non-Roller Type | 2 | FloPump |
18 | 00814321020001 | FloPump (Non-Sterile) | 6000N | The IBC FloPump is a single-use, disposable centrifugal blood pump intended for The IBC FloPump is a single-use, disposable centrifugal blood pump intended for use only with the Medtronic Bio Medicus Bio-Console to pump blood through the extracorporeal bypass circuit during open heart surgery. | KFM | Pump, Blood, Cardiopulmonary Bypass, Non-Roller Type | 2 | FloPump |
19 | 10814321020466 | 8600 | 8600 | The AffloShield is a disposable gown intended for use with the AffloVest product line. | OEA | Non-Surgical Isolation Gown | AffloShield | |
20 | 10814321020374 | 1990N | The IBC Suction Wand is a component of Blood Recovery Suction Systems for use in The IBC Suction Wand is a component of Blood Recovery Suction Systems for use in open heart procedures, autologus blood recovery or blood suction. It is a disposable, single use component. | DTS | Sucker, Cardiotomy Return, Cardiopulmonary Bypass | IBC Suction Wand (Non Sterile) | ||
21 | 10814321020343 | APM52 | The IBC Aortic Punch is a single use, disposable, surgical punch to be used to c The IBC Aortic Punch is a single use, disposable, surgical punch to be used to create an opening(s) in the wall of the aorta to prepare a site for anastomosis. | DWS | Instruments, Surgical, Cardiovascular | IBC Aortic Punch, Medium, 5.2mm | ||
22 | 10814321020299 | APM28 | The IBC Aortic Punch is a single use, disposable, surgical punch to be used to c The IBC Aortic Punch is a single use, disposable, surgical punch to be used to create an opening(s) in the wall of the aorta to prepare a site for anastomosis. | DWS | Instruments, Surgical, Cardiovascular | IBC Aortic Punch, Medium, 2.8mm | ||
23 | 10814321020237 | APL40 | The IBC Aortic Punch is a single use, disposable, surgical punch to be used to c The IBC Aortic Punch is a single use, disposable, surgical punch to be used to create an opening(s) in the wall of the aorta to prepare a site for anastomosis. | DWS | Instruments, Surgical, Cardiovascular | IBC Aortic Punch, Long, 4.0mm | ||
24 | 00814321020209 | 5000S | The Stableline is designed to stabilize and contain one to six tubing lines of v The Stableline is designed to stabilize and contain one to six tubing lines of varying sizes which connect cardiopulmonary bypass equipment for delivery or return of fluids to and from the surgical field. The product attaches to the surgical drapes and prevents the tubing lines from slipping, while keeping them out of the way of appropriate procedures. This component is a disposable, single use item. | KRI | Accessory Equipment, Cardiopulmonary Bypass | 1 | Stableline Tubing Organizer (Sterile) | |
25 | 10814321020312 | APM40 | The IBC Aortic Punch is a single use, disposable, surgical punch to be used to c The IBC Aortic Punch is a single use, disposable, surgical punch to be used to create an opening(s) in the wall of the aorta to prepare a site for anastomosis. | DWS | Instruments, Surgical, Cardiovascular | IBC Aortic Punch, Medium, 4.0mm | ||
26 | 10814321020244 | APL44 | The IBC Aortic Punch is a single use, disposable, surgical punch to be used to c The IBC Aortic Punch is a single use, disposable, surgical punch to be used to create an opening(s) in the wall of the aorta to prepare a site for anastomosis. | DWS | Instruments, Surgical, Cardiovascular | IBC Aortic Punch, Long, 4.4mm | ||
27 | 10814321020220 | APL36 | The IBC Aortic Punch is a single use, disposable, surgical punch to be used to c The IBC Aortic Punch is a single use, disposable, surgical punch to be used to create an opening(s) in the wall of the aorta to prepare a site for anastomosis. | DWS | Instruments, Surgical, Cardiovascular | IBC Aortic Punch, Long, 3.6mm | ||
28 | 00814321020421 | 1980S | The IBC Mini Sucker is a component of Blood Recovery Suction Systems for use in The IBC Mini Sucker is a component of Blood Recovery Suction Systems for use in open heart procedures, autologus blood recovery or blood suction. It is a disposable, single use component. | DTS | Sucker, Cardiotomy Return, Cardiopulmonary Bypass | 2 | IBC Mini Sucker (Sterile) | |
29 | 10814321020411 | 1980N | The IBC Mini Sucker is a component of Blood Recovery Suction Systems for use in The IBC Mini Sucker is a component of Blood Recovery Suction Systems for use in open heart procedures, autologus blood recovery or blood suction. It is a disposable, single use component. | DTS | Sucker, Cardiotomy Return, Cardiopulmonary Bypass | IBC Mini Sucker (Non Sterile) | ||
30 | 10814321020213 | APL28 | The IBC Aortic Punch is a single use, disposable, surgical punch to be used to c The IBC Aortic Punch is a single use, disposable, surgical punch to be used to create an opening(s) in the wall of the aorta to prepare a site for anastomosis. | DWS | Instruments, Surgical, Cardiovascular | IBC Aortic Punch, Long, 2.8mm | ||
31 | 10814321020367 | APM60 | The IBC Aortic Punch is a single use, disposable, surgical punch to be used to c The IBC Aortic Punch is a single use, disposable, surgical punch to be used to create an opening(s) in the wall of the aorta to prepare a site for anastomosis. | DWS | Instruments, Surgical, Cardiovascular | IBC Aortic Punch, Medium, 6.0mm | ||
32 | 10814321020176 | 3080N | The brand name for this component is IBC FloProbe and is part of the AcuFlo syst The brand name for this component is IBC FloProbe and is part of the AcuFlo system of products. This component is used in conjunction with the Medtronic Biomedicus Flow Pump System during open heart procedures. The IBC FloProbe is a direct product substitution for the Medtronic/Biomedicus Bioprobe, DP38. | DPT | Probe, Blood-Flow, Extravascular | FloProbe 3/8’’ x 3/8” (Non Sterile) | ||
33 | 00814321020162 | 3090S | The brand name for this component is IBC FloProbe and is part of the AcuFlo syst The brand name for this component is IBC FloProbe and is part of the AcuFlo system of products. This component is used in conjunction with the Medtronic Biomedicus Flow Pump System during open heart procedures. The IBC FloProbe is a direct product substitution for the Medtronic/Biomedicus Bioprobe, DP38P. | DPT | Probe, Blood-Flow, Extravascular | 2 | FloProbe 1/4’’ x 1/4’’ (Sterile) | |
34 | 10814321020268 | APL52 | The IBC Aortic Punch is a single use, disposable, surgical punch to be used to c The IBC Aortic Punch is a single use, disposable, surgical punch to be used to create an opening(s) in the wall of the aorta to prepare a site for anastomosis. | DWS | Instruments, Surgical, Cardiovascular | IBC Aortic Punch, Long, 5.2mm | ||
35 | 10814321020305 | APM36 | The IBC Aortic Punch is a single use, disposable, surgical punch to be used to c The IBC Aortic Punch is a single use, disposable, surgical punch to be used to create an opening(s) in the wall of the aorta to prepare a site for anastomosis. | DWS | Instruments, Surgical, Cardiovascular | IBC Aortic Punch, Medium, 3.6mm | ||
36 | 10814321020282 | APL60 | The IBC Aortic Punch is a single use, disposable, surgical punch to be used to c The IBC Aortic Punch is a single use, disposable, surgical punch to be used to create an opening(s) in the wall of the aorta to prepare a site for anastomosis. | DWS | Instruments, Surgical, Cardiovascular | IBC Aortic Punch, Long, 6.0mm | ||
37 | 00814321020407 | 5020S | The Tubing Organizer is designed to stabilize and contain one to six tubing line The Tubing Organizer is designed to stabilize and contain one to six tubing lines of varying sizes which connect cardiopulmonary bypass equipment for delivery or return of fluids to and from the surgical field. The product attaches to the surgical drapes and prevents the tubing lines from slipping, while keeping them out of the way of appropriate procedures. This component is a disposable, single use item. | KRI | Accessory Equipment, Cardiopulmonary Bypass | 1 | IBC Tubing Organizer (Sterile) | |
38 | 00814321020384 | 1990S | The IBC Suction Wand is a component of Blood Recovery Suction Systems for use in The IBC Suction Wand is a component of Blood Recovery Suction Systems for use in open heart procedures, autologus blood recovery or blood suction. It is a disposable, single use component. | DTS | Sucker, Cardiotomy Return, Cardiopulmonary Bypass | 2 | IBC Suction Wand (Sterile) | |
39 | 10814321020275 | APL56 | The IBC Aortic Punch is a single use, disposable, surgical punch to be used to c The IBC Aortic Punch is a single use, disposable, surgical punch to be used to create an opening(s) in the wall of the aorta to prepare a site for anastomosis. | DWS | Instruments, Surgical, Cardiovascular | IBC Aortic Punch, Long, 5.6mm | ||
40 | 00814321020186 | 3080S | The brand name for this component is IBC FloProbe and is part of the AcuFlo syst The brand name for this component is IBC FloProbe and is part of the AcuFlo system of products. This component is used in conjunction with the Medtronic Biomedicus Flow Pump System during open heart procedures. The IBC FloProbe is a direct product substitution for the Medtronic/Biomedicus Bioprobe, DP38. | DPT | Probe, Blood-Flow, Extravascular | 2 | FloProbe 3/8" x 3/8” (Sterile) | |
41 | 10814321020336 | APM48 | The IBC Aortic Punch is a single use, disposable, surgical punch to be used to c The IBC Aortic Punch is a single use, disposable, surgical punch to be used to create an opening(s) in the wall of the aorta to prepare a site for anastomosis. | DWS | Instruments, Surgical, Cardiovascular | IBC Aortic Punch, Medium, 4.8mm | ||
42 | 10814321020329 | APM44 | The IBC Aortic Punch is a single use, disposable, surgical punch to be used to c The IBC Aortic Punch is a single use, disposable, surgical punch to be used to create an opening(s) in the wall of the aorta to prepare a site for anastomosis. | DWS | Instruments, Surgical, Cardiovascular | IBC Aortic Punch, Medium, 4.4mm | ||
43 | 10814321020398 | 5020N | The Tubing Organizer is designed to stabilize and contain one to six tubing line The Tubing Organizer is designed to stabilize and contain one to six tubing lines of varying sizes which connect cardiopulmonary bypass equipment for delivery or return of fluids to and from the surgical field. The product attaches to the surgical drapes and prevents the tubing lines from slipping, while keeping them out of the way of appropriate procedures. This component is a disposable, single use item. | KRI | Accessory Equipment, Cardiopulmonary Bypass | IBC Tubing Organizer (Non Sterile) | ||
44 | 10814321020350 | APM56 | The IBC Aortic Punch is a single use, disposable, surgical punch to be used to c The IBC Aortic Punch is a single use, disposable, surgical punch to be used to create an opening(s) in the wall of the aorta to prepare a site for anastomosis. | DWS | Instruments, Surgical, Cardiovascular | IBC Aortic Punch, Medium, 5.6mm | ||
45 | 10814321020251 | APL48 | The IBC Aortic Punch is a single use, disposable, surgical punch to be used to c The IBC Aortic Punch is a single use, disposable, surgical punch to be used to create an opening(s) in the wall of the aorta to prepare a site for anastomosis. | DWS | Instruments, Surgical, Cardiovascular | IBC Aortic Punch, Long, 4.8mm | ||
46 | 10814321020152 | 3090N | The brand name for this component is IBC FloProbe and is part of the AcuFlo syst The brand name for this component is IBC FloProbe and is part of the AcuFlo system of products. This component is used in conjunction with the Medtronic Biomedicus Flow Pump System during open heart procedures. The IBC FloProbe is a direct product substitution for the Medtronic/Biomedicus Bioprobe, DP38P. | DPT | Probe, Blood-Flow, Extravascular | FloProbe 1/4’’ x 1/4" (Non Sterile) |
No | Primary DI | Version or Model | Catalog Number | Device Description | Brand Name | Organization Name |
---|---|---|---|---|---|---|
1 | B066342444NS1 | 342444NS | 342444NS | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, Y 1/2" X 1/2" X 1/2" W/LUER | NOVOSCI CORP. |
2 | B0663424440000 | 342444-000 | 342444-000 | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, Y 1/2" X 1/2" X 1/2" W/LUER | NOVOSCI CORP. |
3 | B066342344NS1 | 342344NS | 342344NS | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, Y 3/8" X 1/2" X 1/2" W/LUER | NOVOSCI CORP. |
4 | B0663423440000 | 342344-000 | 342344-000 | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, Y 3/8" X 1/2" X 1/2" W/LUER | NOVOSCI CORP. |
5 | B066342334NS1 | 342334NS | 342334NS | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, Y 3/8" X 3/8" X 1/2" W/LUER | NOVOSCI CORP. |
6 | B0663423340000 | 342334-000 | 342334-000 | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, Y 3/8" X 3/8" X 1/2" W/LUER | NOVOSCI CORP. |
7 | B066342333NS1 | 342333NS | 342333NS | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, Y 3/8" X 3/8" X 3/8 W/LUER | NOVOSCI CORP. |
8 | B0663423330000 | 342333-000 | 342333-000 | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, Y 3/8" X 3/8" X 3/8" W/LUER | NOVOSCI CORP. |
9 | B0663423320000 | 342332-000 | 342332-000 | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, Y 3/8" X 3/8" X 1/4" W/LUER | NOVOSCI CORP. |
10 | B0663422440000 | 342244-000 | 342244-000 | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, Y 1/4" X 1/2" X 1/2" W/LUER | NOVOSCI CORP. |
11 | B066342233NS1 | 342233NS | 342233NS | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, Y 1/4" X 3/8" X 3/8" W/LUER | NOVOSCI CORP. |
12 | B0663422330000 | 342233-000 | 342233-000 | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, Y 1/4" X 3/8" X 3/8" W/LUER | NOVOSCI CORP. |
13 | B066342223NS1 | 342223NS | 342223NS | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, Y 1/4" X 1/4" X 3/8 W/LUER | NOVOSCI CORP. |
14 | B0663422230000 | 342223-000 | 342223-000 | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, Y 1/4" X 1/4" X 3/8", W/LUER | NOVOSCI CORP. |
15 | B066342222NS1 | 342222NS | 342222NS | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, Y 1/4" X 1/4" X 1/4" W/LUER | NOVOSCI CORP. |
16 | B0663422220000 | 342222-000 | 342222-000 | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, Y 1/4" X 1/4" X 1/4" W/LUER | NOVOSCI CORP. |
17 | B066342112NS1 | 342112NS | 342112NS | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, Y 3/16" 3/16" X 1/4" W/LUER | NOVOSCI CORP. |
18 | B0663421120000 | 342112-000 | 342112-000 | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, Y 3/16" X 3/16" X 1/4" W/LUER | NOVOSCI CORP. |
19 | B066341444NS1 | 341444NS | 341444NS | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, Y 1/2" X 1/2" X 1/2" | NOVOSCI CORP. |
20 | B0663414440000 | 341444-000 | 341444-000 | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, Y 1/2" X 1/2" X 1/2" | NOVOSCI CORP. |
21 | B066341344NS1 | 341344NS | 341344NS | A plastic device designed to join two or more tubes of a cardiopulmonary bypass A plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONNECTOR, Y 3/8" x 1/2" x 1/2" W/O LUER | NOVOSCI CORP. |
22 | B0663413440000 | 341344-000 | 341344-000 | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, Y 3/8" X 1/2" X 1/2" W/O LUER | NOVOSCI CORP. |
23 | B066341334NS1 | 341334NS | 341334NS | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, Y 3/8" X 3/8" X 1/2" | NOVOSCI CORP. |
24 | B0663413340000 | 341334-000 | 341334-000 | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, Y 3/8" X 3/8" X 1/2" | NOVOSCI CORP. |
25 | B066341333NS1 | 341333NS | 341333NS | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, Y 3/8" X 3/8" X 3/8" | NOVOSCI CORP. |
26 | B0663413330000 | 341333-000 | 341333-000 | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, Y 3/8" X 3/8" X 3/8" | NOVOSCI CORP. |
27 | B066341332NS1 | 341332NS | 341332NS | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, Y 3/8" X 3/8" X 1/4" W/O LUER NON-STERILE | NOVOSCI CORP. |
28 | B0663413320000 | 341332-000 | 341332-000 | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, Y 3/8" X 3/8" X 1/4" W/O LUER | NOVOSCI CORP. |
29 | B066341244NS1 | 341244NS | 341244NS | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, Y 1/4" X 1/2" X 1/2" W/O LUER | NOVOSCI CORP. |
30 | B0663412440000 | 341244-000 | 341244-000 | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, Y 1/4" X 1/2" X 1/2" W/O LUER | NOVOSCI CORP. |
31 | B066341233NS1 | 341233NS | 341233NS | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, Y 1/4" X 3/8" X 3/8" W/O LUER | NOVOSCI CORP. |
32 | B0663412330000 | 341233-000 | 341233-000 | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, Y 1/4" X 3/8" X 3/8" W/O LUER | NOVOSCI CORP. |
33 | B066341232NS1 | 341232NS | 341232NS | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, Y 1/4" X 3/8" X 1/4" W/O LUER | NOVOSCI CORP. |
34 | B0663412320000 | 341232-000 | 341232-000 | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, Y 1/4" X 3/8" X 1/4" W/O LUER | NOVOSCI CORP. |
35 | B066341223NS1 | 341223NS | 341223NS | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, Y 1/4" X 1/4" X 3/8" | NOVOSCI CORP. |
36 | B0663412230000 | 341223-000 | 341223-000 | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | Connector, Y 1/4" x 1/4" x 3/8" | NOVOSCI CORP. |
37 | B066341222NS1 | 341222NS | 341222NS | A plastic device designed to join two or more tubes of a cardiopulmonary bypass A plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONNECTOR, Y 1/4" X 1/4" X 1/4" | NOVOSCI CORP. |
38 | B0663412220000 | 341222-000 | 341222-000 | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, Y 1/4" X 1/4" X 1/4" | NOVOSCI CORP. |
39 | B066341112NS1 | 341112NS | 341112NS | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, Y 3/16" X 3/16" X 1/4" W/O LUER | NOVOSCI CORP. |
40 | B0663411120000 | 341112-000 | 341112-000 | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, Y 3/16" X 3/16" X 1/4" W/O LUER | NOVOSCI CORP. |
41 | B066341111NS1 | 341111NS | 341111NS | A plastic device designed to join two or more tubes of a cardiopulmonary bypass A plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONNECTOR, Y 3/16" x 3/16" x 3/16" W/O LUER | NOVOSCI CORP. |
42 | B0663411110000 | 341111-000 | 341111-000 | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, Y 3/16" X 3/16" X 3/16" W/O LUER | NOVOSCI CORP. |
43 | B066332044NS1 | 332044NS | 332044NS | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, 1/2" X 1/2" W/LUER | NOVOSCI CORP. |
44 | B0663320440000 | 332044-000 | 332044-000 | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, 1/2" X 1/2" W/LUER | NOVOSCI CORP. |
45 | B066332034NS1 | 332034NS | 332034NS | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, 3/8" X 1/2" W/O PART LINE W/LUER | NOVOSCI CORP. |
46 | B0663320340000 | 332034-000 | 332034-000 | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, 3/8" X 1/2" W/LUER | NOVOSCI CORP. |
47 | B066332033NS1 | 332033NS | 332033NS | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, 3/8" X 3/8" W/O PART LINE W/LUER | NOVOSCI CORP. |
48 | B0663320330000 | 332033-000 | 332033-000 | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, 3/8" X 3/8" W/LUER | NOVOSCI CORP. |
49 | B066332023NS1 | 332023NS | 332023NS | A plastic device designed to join two or more tubes of a cardiopulmonary bypass A plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONNECTOR, 1/4" X 3/8" W/O PART LINE W/LUER | NOVOSCI CORP. |
50 | B0663320230000 | 332023-000 | 332023-000 | A sterile plastic device designed to join two or more tubes of a cardiopulmonary A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device. | CONN, 1/4" X 3/8" W/LUER | NOVOSCI CORP. |