Other products from "ITL ASIA PACIFIC SDN. BHD."
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 19555240401400 A100730 A100730 Transfer Cap Set is a single-use device intended to aid sterile transfer of flui Transfer Cap Set is a single-use device intended to aid sterile transfer of fluids between blood culture bottles and vacuum tubes. The device is for use by trained laboratory staff, in a laboratory. LIB Device, General Purpose, Microbiology, Diagnostic 1 Transfer Cap Set
2 19555240401196 A500102 A500102 ITL Essentials™ Sharps Passing Tray is intended for safe transfer of sharp instr ITL Essentials™ Sharps Passing Tray is intended for safe transfer of sharp instruments such as surgical scalpels and capped syringes during surgery. For single use only FSM Tray, Surgical, Instrument 1 ITL Essentials™ Sharps Passing Tray, Non-sterile
3 19555240400014 A100709 A100709 SampLok® Adaptor Cap Insert (an optional accessory) can be locked into place ins SampLok® Adaptor Cap Insert (an optional accessory) can be locked into place inside SampLok® Adaptor Cap to facilitate collection of blood sample into vacuum tube(s). It is a single use device. JKA Tubes, Vials, Systems, Serum Separators, Blood Collection SampLok® Adapter Cap Insert
4 09555240401540 A100762 A100762 The SampLok® Adapter Cap has a Luer thread which facilitates attachment with com The SampLok® Adapter Cap has a Luer thread which facilitates attachment with commonly available multi-sample Luer adaptor;It is intended to facilitate collection of blood sample into either culture bottles or vacuum tubes. It is a single use device. JKA Tubes, Vials, Systems, Serum Separators, Blood Collection SampLok® Adapter Cap 3
5 09555240401526 A100760 A100760 The SampLok® Adapter Cap has a Luer thread which facilitates attachment with com The SampLok® Adapter Cap has a Luer thread which facilitates attachment with commonly available multi-sample Luer adaptor;It is intended to facilitate collection of blood sample into either culture bottles or vacuum tubes. It is a single use device. JKA Tubes, Vials, Systems, Serum Separators, Blood Collection SampLok® Adapter Cap 3
6 19555240401431 A100722 A100722 SCU2 is a needleless device used to obtain samples from blood culture bottles an SCU2 is a needleless device used to obtain samples from blood culture bottles and to prevent the risk of a potential needlestick injury. LIB Device, General Purpose, Microbiology, Diagnostic Safety SubCulture Unit 2 (SCU2)
7 19555240401219 A100715 A100715 The SampLok® Adapter Cap has a Luer thread which facilitates attachment with com The SampLok® Adapter Cap has a Luer thread which facilitates attachment with commonly available multi-sample Luer adaptor; It is intended to facilitate collection of blood sample into either a culture bottle or standard vacuum blood tubes. It is a single use device. JKA Tubes, Vials, Systems, Serum Separators, Blood Collection SampLok® Adapter Cap 2
8 19555240401165 A100500 A100500 SampLok® System with No Lid, TR Blue, Assembled with PP Luer, Individual Package SampLok® System with No Lid, TR Blue, Assembled with PP Luer, Individual Packaged, Sterile; Intended to be used as a part of vacuum blood collection equipment for the collection of blood samples for various types of blood tests. JKA,FMI Tubes, Vials, Systems, Serum Separators, Blood Collection,Needle, Hypodermic, Single Lumen 2 SampLok® System with No Lid
9 19555240400960 A100111 A100111 CrocClamp™ (Non-Reopening Clamp) is a device that permanently and completely occ CrocClamp™ (Non-Reopening Clamp) is a device that permanently and completely occludes the tubing fluid path. KSD Device, Heat-Sealing CrocClamp™ (Non-Reopening Clamp)
10 19555240400083 C100400 TiMO™ is intended as a sample test tube holder to assist with the management of TiMO™ is intended as a sample test tube holder to assist with the management of the sample tubes during blood collection. LXG Equipment, Laboratory, General Purpose, Labeled Or Promoted For A Specific Medical Use TiMO™ Tube Management Holder
11 19555240400069 A100422 A100422 SampLok® Hinged Lid 11-18 (Wider Bore), Clear, Bulk, Non-Sterile; Intended as a SampLok® Hinged Lid 11-18 (Wider Bore), Clear, Bulk, Non-Sterile; Intended as a needle holder for a Luer adapter needle to vacuum blood collection tube. JKA Tubes, Vials, Systems, Serum Separators, Blood Collection SampLok® With Hinged Lid
12 09555240401304 A100718 A100718 The SampLok® Adapter Cap has a Luer thread which facilitates attachment with com The SampLok® Adapter Cap has a Luer thread which facilitates attachment with commonly available multi-sample Luer adaptor; Intended to facilitate collection of blood sample into either culture bottles or vacuum tubes. It is a single use device. JKA Tubes, Vials, Systems, Serum Separators, Blood Collection SampLok® Adapter Cap 2
13 19555240400199 A100704 A100704 SampLok® Adaptor Cap Kit (SampLok® Adaptor Cap, clear, assembled with PP Luer, b SampLok® Adaptor Cap Kit (SampLok® Adaptor Cap, clear, assembled with PP Luer, bulk, non-sterile); It is intended to facilitate collection of blood samples into either a culture bottle or standard vacuum blood tubes. FMI,JKA Needle, Hypodermic, Single Lumen,Tubes, Vials, Systems, Serum Separators, Blood Collection SampLok® Adapter Cap Kit
14 19555240400175 A100400 A100400 SampLok without Lid (TitanPro), TR Blue, Bulk, Non-Sterile; It is intended as a SampLok without Lid (TitanPro), TR Blue, Bulk, Non-Sterile; It is intended as a needle holder for a Luer adapter needle to vacuum blood collection tube. JKA Tubes, Vials, Systems, Serum Separators, Blood Collection SampLok®
15 19555240400137 A100100 A100100 DonorCare Needle Guard is intended to aid in the prevention of accidental needle DonorCare Needle Guard is intended to aid in the prevention of accidental needle stick injuries upon completion of blood collection procedures. KSS Supplies, Blood-Bank 1 DonorCare® Needle Guard Small Channel
16 09555240400536 A100740 A100740 SampLok® Sampling Kit (SSK): SSK-Mk2-16mL is used to transfer samples from blood SampLok® Sampling Kit (SSK): SSK-Mk2-16mL is used to transfer samples from blood bags or other containers with sterile docking compatible tubing to vacuum containers for laboratory tests. KSS Supplies, Blood-Bank 1 SampLok® Sampling Kit 16mL
17 19555240400168 A100360 A100360 Platypus® is intended for use in the prevention of accidental needle stick injur Platypus® is intended for use in the prevention of accidental needle stick injuries upon completion of hemodialysis and apheresis procedures;Platypus® has been designed to allow the winged needle assembly to be pulled into the Platypus® and once fully engaged, the winged needle assembly is locked in, thus shielding and locking the needle and preventing needle exposure;Platypus® is supplied bulk, non-sterile. FMI Needle, Hypodermic, Single Lumen Platypus® AV Fistula Needle Guard
18 19555240401332 A200200 A200200 SEG is intended to aid extraction of a biological fluid sample from a segmented SEG is intended to aid extraction of a biological fluid sample from a segmented piece of tubing. KSS Supplies, Blood-Bank Segment Sampler (SEG)
19 19555240401141 A100398 A100398 Standard quiver, PVC loop, polypropylene, individually packaged and sterile.Devi Standard quiver, PVC loop, polypropylene, individually packaged and sterile.Device Intended Use: Holder for electrosurgical diathermy system conducting unit and/or other long instruments during surgery. For single use only. HAM Apparatus, Electrosurgical 2 ITL Essential Standard Quiver
20 19555240401110 A100720 A100720 SCU is a needleless device used to obtain samples from blood culture bottles and SCU is a needleless device used to obtain samples from blood culture bottles and to prevent the risk of a potential needlestick injury. LIB Device, General Purpose, Microbiology, Diagnostic Safety SubCulture Unit (SCU)
21 19555240400205 A100706 A100706 SampLok® Adaptor Cap, Clear, Bulk, Non-sterile; Intended to facilitate collectio SampLok® Adaptor Cap, Clear, Bulk, Non-sterile; Intended to facilitate collection of blood sample into either a culture bottle or standard vacuum blood tubes JKA Tubes, Vials, Systems, Serum Separators, Blood Collection SampLok® Adapter Cap
22 09555240403865 A100752 A100752 SampLok® Sampling Kit (SSK): SSK-Mk3-35mL is used to transfer samples from blood SampLok® Sampling Kit (SSK): SSK-Mk3-35mL is used to transfer samples from blood bags or other containers with sterile docking compatible tubing to vacuum containers for laboratory tests. KSS Supplies, Blood-Bank 1 SampLok® Sampling Kit 35mL
23 09555240401557 A100763 A100763 SampLok® Adaptor Cap 3 (SAC 3) Insert is an optional accessory to be used with S SampLok® Adaptor Cap 3 (SAC 3) Insert is an optional accessory to be used with SAC 3 to facilitate collection of blood sample into vacuum tube(s). It is a single use device. JKA Tubes, Vials, Systems, Serum Separators, Blood Collection SampLok® Adapter Cap 3 Insert
24 09555240401533 A100761 A100761 SampLok® Adaptor Cap 3 (SAC 3) Insert is an optional accessory to be used with S SampLok® Adaptor Cap 3 (SAC 3) Insert is an optional accessory to be used with SAC 3 to facilitate collection of blood sample into vacuum tube(s). It is a single use device. JKA Tubes, Vials, Systems, Serum Separators, Blood Collection SampLok® Adapter Cap 3 Insert
25 09555240400734 A100750 A100750 SampLok® Sampling Kit (SSK): SSK-Mk3-10mL is used to transfer samples from blood SampLok® Sampling Kit (SSK): SSK-Mk3-10mL is used to transfer samples from blood bags or other containers with sterile docking compatible tubing to vacuum containers for laboratory tests. KSS Supplies, Blood-Bank 1 SampLok® Sampling Kit 10mL
26 19555240401134 A100710 A100710 SampLok® Adaptor Cap assembled with PP Luer, Sterile;Intended to facilitate coll SampLok® Adaptor Cap assembled with PP Luer, Sterile;Intended to facilitate collection of blood sample into either a culture bottle or standard vacuum blood tubes JKA,FMI Tubes, Vials, Systems, Serum Separators, Blood Collection,Needle, Hypodermic, Single Lumen 2 SampLok® Safety Adapter Cap with male luer
27 19555240401073 A100111R A100111R CrocClamp™ (Non-Reopening Clamp) is a device that permanently and completely occ CrocClamp™ (Non-Reopening Clamp) is a device that permanently and completely occludes the tubing fluid path. KSD Device, Heat-Sealing 1 CrocClamp™ (Non-Reopening Clamp) - Red
28 19555240400151 A100150 A100150 DonorCare® Needle Guard is intended to aid in the prevention of accidental needl DonorCare® Needle Guard is intended to aid in the prevention of accidental needle stick injuries upon completion of blood collection procedures. KSS Supplies, Blood-Bank 1 DonorCare® Needle Guard Large Channel
29 19555240400854 A100604 A100604 Extendable laparoscopic quiver, PVC loop, polypropylene, individually packaged a Extendable laparoscopic quiver, PVC loop, polypropylene, individually packaged and sterile.Device Intended Use: Holder for electrosurgical diathermy system conducting unit and/or other long instruments during surgery. For single use only. HAM Apparatus, Electrosurgical 2 ITL Essential Laparoscopic Quiver Extendable
30 19555240401158 A100645 A100645 SampLok® System with Hinged Lid (Wider Bore), Clear Assembled with PP Luer, Indi SampLok® System with Hinged Lid (Wider Bore), Clear Assembled with PP Luer, Individual Packaged Sterile;Intended to be used as a part of vacuum blood collection equipment for the collection of blood samples for various types of blood tests JKA,FMI Tubes, Vials, Systems, Serum Separators, Blood Collection,Needle, Hypodermic, Single Lumen 2 SampLok® System with Hinged Lid
31 19555240401080 A500101 A500101 ITL Essentials™ Needle Mat is a plastic lidded tray for collecting, counting and ITL Essentials™ Needle Mat is a plastic lidded tray for collecting, counting and temporarily storing used sharps (suture needles and blades) in the surgical suite. FSM Tray, Surgical, Instrument ITL Essentials™ Needle Mat (Sterile)
32 19555240400076 A100643 A100643 SampLok® Hinged Lid (Wide Bore), Clear, Assembled with PP Luer with Isoprene Sle SampLok® Hinged Lid (Wide Bore), Clear, Assembled with PP Luer with Isoprene Sleeve, Bulk, Non-Sterile; Intended to be used as a part of vacuum blood collection equipment for the collection of blood samples for various types of blood tests FMI,JKA Needle, Hypodermic, Single Lumen,Tubes, Vials, Systems, Serum Separators, Blood Collection SampLok® System with Hinged Lid
33 19555240400045 A100648 A100648 SampLok® Hinged Lid (Wide Bore), Clear, Assembled with PC Luer with Isoprene Sle SampLok® Hinged Lid (Wide Bore), Clear, Assembled with PC Luer with Isoprene Sleeve, Bulk, Non-Sterile; Intended to be used as a part of vacuum blood collection equipment for the collection of blood samples for various types of blood tests FMI,JKA Needle, Hypodermic, Single Lumen,Tubes, Vials, Systems, Serum Separators, Blood Collection SampLok® System with Hinged Lid
34 09555240404084 A100754 A100754 SampLok® Sampling Kit (SSK) - 20mL is used to transfers samples from blood bags SampLok® Sampling Kit (SSK) - 20mL is used to transfers samples from blood bags or other containers with sterile docking compatible tubing to vacuum containers for laboratory tests. KSS Supplies, Blood-Bank 1 SampLok® Sampling Kit 20mL
Other products with the same Product Code "FSM"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 10887587034812 306.82 30682 PLASTIC CUP W/LID FOR ELASTOMERIC INSERTS NA SYNTHES GMBH
2 10887587034805 306.799 306799 SCREW PART NUMBER INSERT FOR 401.558-401.568 NA SYNTHES GMBH
3 10887587034799 306.798 306798 SCREW PART NUMBER INSERT FOR 497.690-497.695 NA SYNTHES GMBH
4 10887587034782 306.797 306797 SCREW PART NUMBER INSERT FOR 497.668-497.678 NA SYNTHES GMBH
5 10887587034775 306.796 306796 SCREW PART NUMBER INSERT FOR 401.508-401.518 NA SYNTHES GMBH
6 10887587034768 306.795 306795 SCREW PART NUMBER INSERT FOR 401.791-401.799 NA SYNTHES GMBH
7 10887587034751 306.794 306794 SCREW PART NUMBER INSERT FOR 401.061-401.065 NA SYNTHES GMBH
8 10887587034737 306.792 306792 SCREW PART NUMBER INSERT FOR 401.041-401.052 NA SYNTHES GMBH
9 10887587034720 306.791 306791 SCREW PART NUMBER INSERT FOR 401.291-401.299 NA SYNTHES GMBH
10 10887587034713 306.789 306789 INSERT TRAY FOR SUBCONDYLAR PLATES FOR MATRIXMANDIBLE MatrixMANDIBLE SYNTHES GMBH
11 10887587034690 306.787 306787 MATRIX AUX INSERT TRAY/SMALL MANDIBLE/MIDFACE/ORTHOGNATHIC Matrix SYNTHES GMBH
12 10887587034683 306.786 306786 MATRIX AUX INSERT TRAY/MED MANDIBLE/MIDFACE/ORTHOGNATHIC Matrix SYNTHES GMBH
13 10887587034676 306.785 306785 INSERT TRAY F/2.0MM PLATES FOR MATRIXMANDIBLE SYSTEM MatrixMANDIBLE SYNTHES GMBH
14 10887587034669 306.784 306784 INSERT TRAY F/1.5MM PLATES FOR MATRIXMANDIBLE SYSTEM MatrixMANDIBLE SYNTHES GMBH
15 10887587034652 306.783 306783 INSERT TRAY F/1.25MM PLATES FOR MATRIXMANDIBLE SYSTEM MatrixMANDIBLE SYNTHES GMBH
16 10887587034645 306.782 306782 INSERT TRAY F/1.0MM PLATES FOR MATRIXMANDIBLE SYSTEM MatrixMANDIBLE SYNTHES GMBH
17 10887587034638 306.781 306781 INSERT F/1.0MM MALLEABLE PLATE FOR MATRIXMANDIBLE SYSTEM MatrixMANDIBLE SYNTHES GMBH
18 10887587034614 306.778 306778 MATRIX AUX MODULE/MEDIUM MANDIBLE/MIDFACE/ORTHOGNATHIC Matrix SYNTHES GMBH
19 10887587034607 306.777 306777 GRAPHIC CASE MEDIUM FOR MATRIXMANDIBLE SYSTEM MatrixMANDIBLE SYNTHES GMBH
20 10887587034577 306.772 306772 GENERIC SCREW INSERT TRAY FOR MATRIXMANDIBLE SYSTEM MatrixMANDIBLE SYNTHES GMBH
21 10887587034560 306.770 306770 2.0MM SCREW INSERT TRAY FOR MATRIXMANDIBLE SYSTEM MatrixMANDIBLE SYNTHES GMBH
22 10887587034461 306.760 306760 IMF SCREW MODULE FULL SIZE MATRIXMANDIBLE SYSTEM MatrixMANDIBLE SYNTHES GMBH
23 10887587034447 306.757 306757 IMF SCREW MODULE/COMPACT MATRIXMANDIBLE SYSTEM MatrixMANDIBLE SYNTHES GMBH
24 10887587034430 306.755 306755 LAG SCREW MODULE MATRIXMANDIBLE SYSTEM MatrixMANDIBLE SYNTHES GMBH
25 10887587034423 306.752 306752 IMF SCREW MODULE/MINI MATRIXMANDIBLE SYSTEM MatrixMANDIBLE SYNTHES GMBH
26 10887587034416 306.749 306749 LARGE PLATE MODULE FOR MATRIXMANDIBLE SYSTEM MatrixMANDIBLE SYNTHES GMBH
27 10887587034409 306.748 306748 LARGE PLATE MODULE LID FOR MATRIXMANDIBLE SYSTEM MatrixMANDIBLE SYNTHES GMBH
28 10887587034393 306.747 306747 2.0MM/2.5MM DBL ANGLE PL INSRT TRAY FOR MATRIXMANDIBLE SYSTE MatrixMANDIBLE SYNTHES GMBH
29 10887587034386 306.746 306746 2.8MM PLATE INSERT TRAY FOR MATRIXMANDIBLE SYSTEM MatrixMANDIBLE SYNTHES GMBH
30 10887587034379 306.745 306745 RECON SCREW CADDY INSERT TRAY FOR MATRIXMANDIBLE SYSTEM MatrixMANDIBLE SYNTHES GMBH
31 10887587034355 306.743 306743 SCREW MODULE LID FOR MATRIXMANDIBLE SYSTEM MatrixMANDIBLE SYNTHES GMBH
32 10887587034348 306.742 306742 SCREW MODULE FOR MATRIXMANDIBLE SYSTEM MatrixMANDIBLE SYNTHES GMBH
33 10887587034331 306.741 306741 SMALL PLATE MODULE LID FOR MATRIXMANDIBLE SYSTEM MatrixMANDIBLE SYNTHES GMBH
34 10887587034324 306.740 306740 SMALL PLATE MODULE FOR MATRIXMANDIBLE SYSTEM MatrixMANDIBLE SYNTHES GMBH
35 10887587034317 306.739 306739 LID F/INSTR TRAY/LARGE MATRIXMANDIBLE GRAPHIC CASE MatrixMANDIBLE SYNTHES GMBH
36 10887587034287 306.733 306733 TROCAR INSTRUMENT MODULE MATRIXMANDIBLE MatrixMANDIBLE SYNTHES GMBH
37 10887587034270 306.732 306732 INSTRUMENT TRAY MATRIXMANDIBLE MatrixMANDIBLE SYNTHES GMBH
38 10887587034263 306.731 306731 INSTRUMENT TRAY MATRIXMANDIBLE MatrixMANDIBLE SYNTHES GMBH
39 10887587034256 306.728 306728 HOLDER F/CALIBRATED DRILL BITS MATRIXMANDIBLE SYSTEM MatrixMANDIBLE SYNTHES GMBH
40 10887587034249 306.727 306727 LID F/INSTR TRAY/MEDIUM MATRIXMANDIBLE GRAPHIC CASE MatrixMANDIBLE SYNTHES GMBH
41 10887587034232 306.726 306726 FINGER MAT F/USE W/306.702 FOR MATRIXMANDIBLE SYSTEM MatrixMANDIBLE SYNTHES GMBH
42 10887587034218 306.721 306721 LID FOR MANDIBLE EXTERNAL FIXATOR II SET GRAPHIC CASE NA SYNTHES GMBH
43 10887587034201 306.720 306720 BASE FOR MANDIBLE EXTERNAL FIXATOR II SET GRAPHIC CASE NA SYNTHES GMBH
44 10887587034171 306.714 306714 INSERT TRAY F/BENDING PLIERS FOR MATRIXMANDIBLE SYSTEM MatrixMANDIBLE SYNTHES GMBH
45 10887587034164 306.713 306713 INSERT TRAY F/BENDING INSTR FOR MATRIXMANDIBLE SYSTEM MatrixMANDIBLE SYNTHES GMBH
46 10887587034157 306.712 306712 INSERT TRAY F/TROCAR INSTR FOR MATRIXMANDIBLE SYSTEM MatrixMANDIBLE SYNTHES GMBH
47 10887587034140 306.711 306711 LID FOR MANDIBLE EXTERNAL FIXATOR SET GRAPHIC CASE NA SYNTHES GMBH
48 10887587034133 306.710 306710 BASE FOR MANDIBLE EXTERNAL FIXATOR SET GRAPHIC CASE NA SYNTHES GMBH
49 10887587034102 306.707 306707 INSTR TRAY F/GRAPHIC CASE/MED MATRIXMANDIBLE TROCAR/DRIVERS MatrixMANDIBLE SYNTHES GMBH
50 10887587034065 306.703 306703 GRAPHIC CASE LID FOR MATRIXMANDIBLE SYSTEM MatrixMANDIBLE SYNTHES GMBH