The Integra External Fixation System set consists of rings and footplates. These
The Integra External Fixation System set consists of rings and footplates. These devices are used for stability and structure. The external fixation device is intended for use in the treatment of bone conditions including leg lengthening, osteotomies, arthrodesis, fracture fixation, and other bone conditions amenable to treatment by use of the external fixation modality.
The Integra External Fixation System set consists of rings, footplates, anterior
The Integra External Fixation System set consists of rings, footplates, anterior cross bars, and a rockerbottom. These devices are used for stability and structure. The external fixation device is intended for use in the treatment of bone conditions including leg lengthening, osteotomies, arthrodesis, fracture fixation, and other bone conditions amenable to treatment by use of the external fixation modality.
The Integra External Fixation System set consists of struts, rods, and hex posts
The Integra External Fixation System set consists of struts, rods, and hex posts. These devices are used for support in the construct. Plates and a universal joint are also included. The external fixation device is intended for use in the treatment of bone conditions including leg lengthening, osteotomies, arthrodesis, fracture fixation, and other bone conditions amenable to treatment by use of the external fixation modality.
The Integra External Fixation System set consists of wires, half-pins, nuts, and
The Integra External Fixation System set consists of wires, half-pins, nuts, and bolts. Instruments are also included to aid in assembly. The external fixation device is intended for use in the treatment of bone conditions including leg lengthening, osteotomies, arthrodesis, fracture fixation, and other bone conditions amenable to treatment by use of the external fixation modality.
The Integra External Fixation System two-post bridge is manufactured from stainl
The Integra External Fixation System two-post bridge is manufactured from stainless steel. It is intended for the treatment of bone conditions including leg lengthening, osteotomies, arthrodesis, fracture fixation, and other bone conditions amenable to treatment by use of external fixation.
The Integra External Fixation System half ring is used for stability and structu
The Integra External Fixation System half ring is used for stability and structure. It is manufactured from aluminum. It is intended for the treatment of bone conditions including leg lengthening, osteotomies, arthrodesis, fracture fixation, and other bone conditions amenable to treatment by use of external fixation.
The Integra External Fixation System 5/8 ring is used for stability and structur
The Integra External Fixation System 5/8 ring is used for stability and structure. It is manufactured from aluminum. It is intended for the treatment of bone conditions including leg lengthening, osteotomies, arthrodesis, fracture fixation, and other bone conditions amenable to treatment by use of external fixation.
The Integra External Fixation System half ring is used for stability and structu
The Integra External Fixation System half ring is used for stability and structure. It is manufactured from aluminum. It is intended for the treatment of bone conditions including leg lengthening, osteotomies, arthrodesis, fracture fixation, and other bone conditions amenable to treatment by use of external fixation.
The Integra External Fixation System full ring is used for stability and structu
The Integra External Fixation System full ring is used for stability and structure. It is manufactured from aluminum. It is intended for the treatment of bone conditions including leg lengthening, osteotomies, arthrodesis, fracture fixation, and other bone conditions amenable to treatment by use of external fixation.
The Integra External Fixation System 5/8 ring is used for stability and structur
The Integra External Fixation System 5/8 ring is used for stability and structure. It is manufactured from aluminum. It is intended for the treatment of bone conditions including leg lengthening, osteotomies, arthrodesis, fracture fixation, and other bone conditions amenable to treatment by use of external fixation.
The Integra External Fixation System anterior half ring is used for stability an
The Integra External Fixation System anterior half ring is used for stability and structure. It is manufactured from aluminum. It is intended for the treatment of bone conditions including leg lengthening, osteotomies, arthrodesis, fracture fixation, and other bone conditions amenable to treatment by use of external fixation.
The Integra External Fixation System half ring is used for stability and structu
The Integra External Fixation System half ring is used for stability and structure. It is manufactured from aluminum. It is intended for the treatment of bone conditions including leg lengthening, osteotomies, arthrodesis, fracture fixation, and other bone conditions amenable to treatment by use of external fixation.
The Integra External Fixation System full ring is used for stability and structu
The Integra External Fixation System full ring is used for stability and structure. It is manufactured from aluminum. It is intended for the treatment of bone conditions including leg lengthening, osteotomies, arthrodesis, fracture fixation, and other bone conditions amenable to treatment by use of external fixation.
The Integra External Fixation System 5/8 ring is used for stability and structur
The Integra External Fixation System 5/8 ring is used for stability and structure. It is manufactured from aluminum. It is intended for the treatment of bone conditions including leg lengthening, osteotomies, arthrodesis, fracture fixation, and other bone conditions amenable to treatment by use of external fixation.
The Integra External Fixation System footplate is used for stability and structu
The Integra External Fixation System footplate is used for stability and structure. It is manufactured from aluminum. It is intended for the treatment of bone conditions including leg lengthening, osteotomies, arthrodesis, fracture fixation, and other bone conditions amenable to treatment by use of external fixation.
A rockerbottom is attached to the bottom of the external device so that the pati
A rockerbottom is attached to the bottom of the external device so that the patient may stand on it if needed. It is manufactured from aluminum and silicone rubber.
A crossbar is manufactured from stainless steel and aluminum. It may be attached
A crossbar is manufactured from stainless steel and aluminum. It may be attached to the anterior ring for additional support.
A crossbar is manufactured from stainless steel and aluminum. It may be attached
A crossbar is manufactured from stainless steel and aluminum. It may be attached to the anterior ring for additional support.
The Integra External Fixation System anterior half ring is used for stability an
The Integra External Fixation System anterior half ring is used for stability and structure. It is manufactured from aluminum. It is intended for the treatment of bone conditions including leg lengthening, osteotomies, arthrodesis, fracture fixation, and other bone conditions amenable to treatment by use of external fixation.
The Integra External Fixation System half ring is used for stability and structu
The Integra External Fixation System half ring is used for stability and structure. It is manufactured from aluminum. It is intended for the treatment of bone conditions including leg lengthening, osteotomies, arthrodesis, fracture fixation, and other bone conditions amenable to treatment by use of external fixation.
The Integra External Fixation System full ring is used for stability and structu
The Integra External Fixation System full ring is used for stability and structure. It is manufactured from aluminum. It is intended for the treatment of bone conditions including leg lengthening, osteotomies, arthrodesis, fracture fixation, and other bone conditions amenable to treatment by use of external fixation.
The Integra External Fixation System 5/8 ring is used for stability and structur
The Integra External Fixation System 5/8 ring is used for stability and structure. It is manufactured from aluminum. It is intended for the treatment of bone conditions including leg lengthening, osteotomies, arthrodesis, fracture fixation, and other bone conditions amenable to treatment by use of external fixation.
The Integra External Fixation System footplate is used for stability and structu
The Integra External Fixation System footplate is used for stability and structure. It is manufactured from aluminum. It is intended for the treatment of bone conditions including leg lengthening, osteotomies, arthrodesis, fracture fixation, and other bone conditions amenable to treatment by use of external fixation.
The Integra External Fixation System anterior half ring is used for stability an
The Integra External Fixation System anterior half ring is used for stability and structure. It is manufactured from aluminum. It is intended for the treatment of bone conditions including leg lengthening, osteotomies, arthrodesis, fracture fixation, and other bone conditions amenable to treatment by use of external fixation.
The Integra External Fixation System half ring is used for stability and structu
The Integra External Fixation System half ring is used for stability and structure. It is manufactured from aluminum. It is intended for the treatment of bone conditions including leg lengthening, osteotomies, arthrodesis, fracture fixation, and other bone conditions amenable to treatment by use of external fixation.
The Integra External Fixation System full ring is used for stability and structu
The Integra External Fixation System full ring is used for stability and structure. It is manufactured from aluminum. It is intended for the treatment of bone conditions including leg lengthening, osteotomies, arthrodesis, fracture fixation, and other bone conditions amenable to treatment by use of external fixation.
The Integra External Fixation System 5/8 ring is used for stability and structur
The Integra External Fixation System 5/8 ring is used for stability and structure. It is manufactured from aluminum. It is intended for the treatment of bone conditions including leg lengthening, osteotomies, arthrodesis, fracture fixation, and other bone conditions amenable to treatment by use of external fixation.
The Integra External Fixation System footplate is used for stability and structu
The Integra External Fixation System footplate is used for stability and structure. It is manufactured from aluminum. It is intended for the treatment of bone conditions including leg lengthening, osteotomies, arthrodesis, fracture fixation, and other bone conditions amenable to treatment by use of external fixation.
The universal joint is made from stainless steel. It is used to aid in the assem
The universal joint is made from stainless steel. It is used to aid in the assembly of the Integra External Fixation System.
The strut is an adjustable component designed to facilitate building and maintai
The strut is an adjustable component designed to facilitate building and maintaining frames, from initial surgery to follow-up care. This strut features an unlocked mode, where large adjustments may be made to the component’s vertical translation. It also features two distal ends which are designed to enable construction of frames with offset rings or different diameter rings. The tightened mode allows for fine adjustments in vertical translation; this enables surgeons to conveniently apply compression and distraction to the frame, both intra-operatively and post-operatively. The fully locked mode restricts translation and angular movement creating a rigid construct.
The strut is an adjustable component designed to facilitate building and maintai
The strut is an adjustable component designed to facilitate building and maintaining frames, from initial surgery to follow-up care. This strut features an unlocked mode, where large adjustments may be made to the component’s vertical translation. It also features one distal end which is designed to enable construction of frames with offset rings or different diameter rings. The tightened mode allows for fine adjustments in vertical translation; this enables surgeons to conveniently apply compression and distraction to the frame, both intra-operatively and post-operatively. The fully locked mode restricts translation and angular movement creating a rigid construct.
The strut is an adjustable component designed to facilitate building and maintai
The strut is an adjustable component designed to facilitate building and maintaining frames, from initial surgery to follow-up care. This strut features a tightened mode which allows for fine adjustments in vertical translation; this enables surgeons to conveniently apply compression and distraction to the frame, both intra-operatively and post-operatively. The fully locked mode restricts translation and angular movement creating a rigid construct.
The threaded rod is used to connect and support rings in the construct. The rod
The threaded rod is used to connect and support rings in the construct. The rod is made from stainless steel.
The threaded rod is used to connect and support rings in the construct. The rod
The threaded rod is used to connect and support rings in the construct. The rod is made from stainless steel.
The threaded rod is used to connect and support rings in the construct. The rod
The threaded rod is used to connect and support rings in the construct. The rod is made from stainless steel.
The threaded rod is used to connect and support rings in the construct. The rod
The threaded rod is used to connect and support rings in the construct. The rod is made from stainless steel.
The threaded rod is used to connect and support rings in the construct. The rod
The threaded rod is used to connect and support rings in the construct. The rod is made from stainless steel.
The threaded rod is used to connect and support rings in the construct. The rod
The threaded rod is used to connect and support rings in the construct. The rod is made from stainless steel.
The Integra External Fixation System plate is manufactured from stainless steel.
The Integra External Fixation System plate is manufactured from stainless steel. It is intended for the treatment of bone conditions including leg lengthening, osteotomies, arthrodesis, fracture fixation, and other bone conditions amenable to treatment by use of external fixation.
The Integra External Fixation System three-hole plate is manufactured from stain
The Integra External Fixation System three-hole plate is manufactured from stainless steel. It is intended for the treatment of bone conditions including leg lengthening, osteotomies, arthrodesis, fracture fixation, and other bone conditions amenable to treatment by use of external fixation.
The hex post is used to connect and support rings in the construct. The hex post
The hex post is used to connect and support rings in the construct. The hex post is made from stainless steel.
The hex post is used to connect and support rings in the construct. The hex post
The hex post is used to connect and support rings in the construct. The hex post is made from stainless steel.
The hex post is used to connect and support rings in the construct. The hex post
The hex post is used to connect and support rings in the construct. The hex post is made from stainless steel.
The angular half pin fixation clamp is made from stainless steel and is used to
The angular half pin fixation clamp is made from stainless steel and is used to connect half pins to the rings.
The slotted post is used to achieve greater distances off the ring of the Integr
The slotted post is used to achieve greater distances off the ring of the Integra External Fixation System. This allows not only greater distance for the wire off the ring, but for multiple degrees of freedom in wire placement that a standard fixation bolt does not permit.