Other products from "FIAB SPA"
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 38033695725982 F9070 F9070 Disposable ECG electrodes, round-shaped Ø 50mm, pre-gelled and equipped with sn Disposable ECG electrodes, round-shaped Ø 50mm, pre-gelled and equipped with snap connection. F9070 model has features that make it absolutely reliable during signal recording with all different ECG on the market in stress tests and holter. DRX Electrode, Electrocardiograph NA
2 18033695727456 F7244/1 F7244/1 HTC (high temperature cautery) F7244/1 model is a sterile bipolar battery opera HTC (high temperature cautery) F7244/1 model is a sterile bipolar battery operated disposable device used for the cauterization of tissues and capillary vessels. F7244/1 model is equipped with fine tip that permits the cauterization of very small vessels and is suitable to be used all the times a quick and precise cauterization is necessary. F7244/1 reaches a maximum working temperature of 1.200°C (2.200 °F). GEI Electrosurgical, Cutting & Coagulation & Accessories NA
3 18033695727449 F7234/1 F7234/1 HTC (high temperature cautery) F7234/1 model is a sterile bipolar battery operat HTC (high temperature cautery) F7234/1 model is a sterile bipolar battery operated disposable device for the cauterization of small vessels. The fine tip length 75mm permits the accurate and effective cauterization of very small vessels. Tip reaches a maximum working temperature of 1.200°C (2.200 °F). The cautery is suitable to be used all the times a quick and precise cauterization is necessary even in difficult access sites. GEI Electrosurgical, Cutting & Coagulation & Accessories 2 NA
4 18033695727180 F7234 F7234 HTC (high temperature cautery) F7234 model is a sterile bipolar battery operated HTC (high temperature cautery) F7234 model is a sterile bipolar battery operated disposable device for the cauterization of small vessels. The fine tip length 75mm permits the accurate and effective cauterization of very small vessels. Tip reaches a maximum working temperature of 1.200°C (2.200 °F). The cautery is suitable to be used all the times a quick and precise cauterization is necessary even in difficult access sites. GEI Electrosurgical, Cutting & Coagulation & Accessories 2 NA
5 18033695727159 F7255 F7255 LTC (low temperature cautery) F7255 model is a sterile bipolar battery operated LTC (low temperature cautery) F7255 model is a sterile bipolar battery operated disposable device used for the cauterization of tissues and capillary vessels. F7255 model is equipped with fine tip and reaches a maximum working temperature of 600°C (1100°F). It is mainly used for ophtalmology procedures, but is suitable to be used whenever a quick and precise cauterization is necessary, reducing possible damages to surroundings tissues. GEI Electrosurgical, Cutting & Coagulation & Accessories 2 NA
6 18033695727142 F7244 F7244 HTC (high temperature cautery) F7244 model is a sterile bipolar battery operate HTC (high temperature cautery) F7244 model is a sterile bipolar battery operated disposable device used for the cauterization of tissues and capillary vessels. F7244 model is equipped with fine tip that permits the cauterization of very small vessels and is suitable to be used all the times a quick and precise cauterization is necessary. F7244 reaches a maximum working temperature of 1.200°C (2.200 °F). GEI Electrosurgical, Cutting & Coagulation & Accessories NA
7 18033695724851 F9053/41 F9053/41 Disposable ECG monitoring electrodes have features that make them abs Disposable ECG monitoring electrodes have features that make them absolutely reliable during long monitoring ECG recording (not longer than 72 hours). F9053/41 model are round-shaped electrodes, Ø 41mm, equipped with 35 cm long wire and 4mm socket, pre-gelled and they can be easily connected to the ECG monitor, avoiding pressure on the skin. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids. DRX Electrode, Electrocardiograph NA
8 08054953345864 A113 A113 FIAB reusable praecordial suction chest electrodes for ECG, ball diameter Ø 33mm FIAB reusable praecordial suction chest electrodes for ECG, ball diameter Ø 33mm and rubber ring diameter Ø 30mm. A113 model has features that make it absolutely reliable during signal recording with all different ECG devices on the market. The metallic part is silver coated (Ag/AgCl) allowing a safe and clear signal transmission. The rings are made of rubber to improve patient’s comfort. FIAB suction chest electrodes thanks to screw and clip connections, can be tapped to all ECG devices and monitors with patient cables which have plug or snap connections. The product is latex-free and without Nickel IKD Cable, Electrode NA
9 08054953343266 F9060X/AUS F9060X/AUS Disposable ECG electrodes, oval-shaped 50x48mm dimensions,Silver/Silver Chlori Disposable ECG electrodes, oval-shaped 50x48mm dimensions,Silver/Silver Chloride(SSC) sensor and stainless steel snap. F9060 model is suitable for rest, long term, stress or Holter ECG recording, with a direct application onto the skin. The SSC sensor permits a reliable and stable recording. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids DRX Electrode, Electrocardiograph NA
10 08054953344027 F9010SSC-6 F9010SSC-6 Reusable peripheral electrodes for ECG, 31.5x22mm dimensions, have features that Reusable peripheral electrodes for ECG, 31.5x22mm dimensions, have features that make them absolutely reliable during signal recording with all different ECG recorders on the market. The metallic part is silver coated (Ag/AgCl) allowing a safe and clear signal transmission. F9010SSC-6 thanks to screw and snap connections, can be tapped to all ECG recorders and monitors both with plug and snap. To be used with fasten belts.The product is Latex-free and Nickel-free. DRX Electrode, Electrocardiograph NA
11 08054953343921 F6217USA F6217USA Reusable ECG patient cables 7 leads, with 2mm protected plug. IKD Cable, Electrode 2 NA
12 08054953341071 F9057N F9057N F9057N model is a disposable oval-shaped ECG monitoring electrodes have features F9057N model is a disposable oval-shaped ECG monitoring electrodes have features that make them absolutely reliable during long monitoring ECG recording (not longer than 72 hours). F9057N is pre-gelled, 23x30mm dimensions, equipped with 50cm long wire and DIN 42802-1 1.5mm socket. The external surface is made of non woven fabric. The fabric is made of plastic polyethylene fiber (and not natural fiber) that guarantees the transpiration of the skin, but at the same time the resistance to liquids with which they may come into contact during their use.Pediatric and Neonatal model. DRX Electrode, Electrocardiograph NA
13 08054953343501 F9047RM F9047RM Disposable ECG RADIOLUCENT electrodes with liquid gel, 32x44mm dimensions, Silve Disposable ECG RADIOLUCENT electrodes with liquid gel, 32x44mm dimensions, Silver/Silver Chloride (SSC) sensor and carbon snap. F9047RM model is suitable both for rest and stress or Holter ECG recording, with a direct application onto the skin.The SSC sensor permits a reliable and stable recording. The peculiar feature of the electrode is the carbon snap that makes it radiolucent. Neither of the components contains any ferromagnetic materials, therefore the electrodes are fully compatible with MRI applications. The electrodes are MRI tested for use up to 3 T electro-magnetic field. The use of the electrodes do not affect the safety and functioning of Magnetic Resonance Imaging Systems. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids DRX Electrode, Electrocardiograph NA
14 08054953343495 F9046RM F9046RM Disposable ECG RADIOLUCENT electrodes with solid gel, 28x44mm dimensions, Silver Disposable ECG RADIOLUCENT electrodes with solid gel, 28x44mm dimensions, Silver/Silver Chloride(SSC) sensor and carbon snap. F9046RM model is suitable both for rest and stress or Holter ECG recording, with a direct application onto the skin. The SSC sensor permits a reliable and stable recording. The peculiar feature of the electrode is the carbon snap that makes it radiolucent. Neither of the components contains any ferromagnetic materials, therefore the electrodes are fully compatible with MRI applications. The electrodes are MRI tested for use up to 3 T electro-magnetic field. The use of the electrodes do not affect the safety and functioning of Magnetic Resonance Imaging Systems. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids DRX Electrode, Electrocardiograph NA
15 08054953342191 F9046 F9046 Disposable ECG electrodes with solid gel, 28x44mm dimensions,Silver/Silver Chlo Disposable ECG electrodes with solid gel, 28x44mm dimensions,Silver/Silver Chloride(SSC) sensor and stainless steel snap. F9046 model is suitable both for rest and stress or Holter ECG recording, with a direct application onto the skin. The SSC sensor permits a reliable and stable recording. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids. DRX Electrode, Electrocardiograph NA
16 08054953341248 F2017/4FL F2017/4FL Disposable oval-shaped ECG electrodes with liquid gel, Silver/Silver Chlor Disposable oval-shaped ECG electrodes with liquid gel, Silver/Silver Chloride(SSC) sensor, 52x32mm dimensions and with 4mm socket . These electrodes dimensions have features that make them absolutely reliable during signal recording in rest tests, with a direct application onto the skin. The SSC sensor permits a reliable and stable recording and off-centered configuration allows a better quality of ECG signal and reduces artifacts. They comply with ANSI/AAMI EC12:2000 permitting the signal recovery after defibrillator discharge. After opening, the pouch can be folded to ensure a better preservation of the electrodes that remain inside. The products are latex-free. DRX Electrode, Electrocardiograph NA
17 08054953341231 F2017P F2017P Disposable round-shaped ECG electrodes with liquid gel, Ø 42mm, Silver/Sil Disposable round-shaped ECG electrodes with liquid gel, Ø 42mm, Silver/Silver Chloride(SSC) sensor and metal snap. These electrodes are suitable for short and medium term monitoring, stress ECG recording and Holter, with a direct application onto the skin. The SSC sensor permits a reliable and stable recording and off-centered configuration allows a better quality of ECG signal and reduces artifacts. DRX Electrode, Electrocardiograph NA
18 08054953341224 F2017 F2017 Disposable round-shaped ECG electrodes with liquid gel, Ø 50mm, Silver/Sil Disposable round-shaped ECG electrodes with liquid gel, Ø 50mm, Silver/Silver Chloride(SSC) sensor and metal snap. These electrodes are suitable for short and medium term monitoring, stress ECG recording and Holter, with a direct application onto the skin. The SSC sensor permits a reliable and stable recording and off-centered configuration allows a better quality of ECG signal and reduces artifacts. DRX Electrode, Electrocardiograph NA
19 08054953341217 F2017H F2017H Disposable round-shaped ECG electrodes with liquid gel, Ø 60mm, Silver/Sil Disposable round-shaped ECG electrodes with liquid gel, Ø 60mm, Silver/Silver Chloride(SSC) sensor and metal snap. These electrodes are suitable for short and medium term monitoring, stress ECG recording and Holter, with a direct application onto the skin. The SSC sensor permits a reliable and stable recording and off-centered configuration allows a better quality of ECG signal and reduces artifacts. DRX Electrode, Electrocardiograph NA
20 08054953341101 F9057PRRM F9057PRRM F9057PRRM model is a disposable round-shaped ECG monitoring electrodes have feat F9057PRRM model is a disposable round-shaped ECG monitoring electrodes have features that make them absolutely reliable during long monitoring ECG recording (not longer than 72 hours). F9057PRRM is pre-gelled, Ø 32mm, equipped with 50cm long wire and DIN 42802-1 1.5mm socket. The external surface is made of non woven fabric. The fabric is made of plastic polyethylene fiber (and not natural fiber) that guarantees the transpiration of the skin, but at the same time the resistance to liquids with which they may come into contact during their use. Neonatal and Premature model.F9057PRRM model is radiotranslucent, therefore it allows the user to perform radiographic procedures without removing the electrode. DRX Electrode, Electrocardiograph NA
21 08054953341095 F9057PR F9057PR F9057PR model is a disposable oval-shaped ECG monitoring electrodes have feature F9057PR model is a disposable oval-shaped ECG monitoring electrodes have features that make them absolutely reliable during long monitoring ECG recording (not longer than 72 hours). F9057PR is pre-gelled, 20x15mm dimensions, equipped with 50cm long wire and DIN 42802-1 1.5mm socket. The external surface is made of non woven fabric. The fabric is made of plastic polyethylene fiber (and not natural fiber) that guarantees the transpiration of the skin, but at the same time the resistance to liquids with which they may come into contact during their use. Neonatal and premature model. DRX Electrode, Electrocardiograph NA
22 08054953341088 F9057NRM F9057NRM F9057NRM model is a disposable oval-shaped ECG monitoring electrodes have featur F9057NRM model is a disposable oval-shaped ECG monitoring electrodes have features that make them absolutely reliable during long monitoring ECG recording (not longer than 72 hours). F9057NRM is pre-gelled, 23x30mm dimensions, equipped with 50cm long wire and DIN 42802-1 1.5mm socket. The external surface is made of non woven fabric. The fabric is made of plastic polyethylene fiber (and not natural fiber) that guarantees the transpiration of the skin, but at the same time the resistance to liquids with which they may come into contact during their use. Pediatric and Neonatal model.F9057NRM model is radiotranslucent, therefore it allows the user to perform radiographic procedures without removing the electrode. DRX Electrode, Electrocardiograph NA
23 08033695728623 F9058P/60 F9058P/60 Disposable ECG monitoring electrodes have features that make them abs Disposable ECG monitoring electrodes have features that make them absolutely reliable during long monitoring ECG recording (not longer than 72 hours). F9058P/60 model is round-shaped electrodes, Ø 32mm,pre-gelled, equipped with 60cm long wire and DIN 42802-1 1.5mm socket. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids. DRX Electrode, Electrocardiograph NA
24 08054953341064 F9057PRM F9057PRM F9057PRM model is a disposable round-shaped ECG monitoring electrodes have featu F9057PRM model is a disposable round-shaped ECG monitoring electrodes have features that make them absolutely reliable during long monitoring ECG recording (not longer than 72 hours). F9057PRM is pre-gelled, Ø 32mm, equipped with 50cm long wire and DIN 42802-1 1.5mm socket. The external surface is made of non woven fabric. The fabric is made of plastic polyethylene fiber (and not natural fiber) that guarantees the transpiration of the skin, but at the same time the resistance to liquids with which they may come into contact during their use. Adult and Pediatric model.F9057PRM model is radiotranslucent, therefore it allows the user to perform radiographic procedures without removing the electrode. DRX Electrode, Electrocardiograph NA
25 08054953341057 F9057P F9057P F9057P model is a disposable round-shaped ECG monitoring electrodes have feature F9057P model is a disposable round-shaped ECG monitoring electrodes have features that make them absolutely reliable during long monitoring ECG recording (not longer than 72 hours). F9057P is pre-gelled, Ø 32mm and equipped with 50cm long wire with DIN 42802-1 1.5mm socket. The external surface is made of non woven fabric. The fabric is made of plastic polyethylene fiber (and not natural fiber) that guarantees the transpiration of the skin, but at the same time the resistance to liquids with which they may come into contact during their use. DRX Electrode, Electrocardiograph NA
26 08054953340449 F9060/5 F9060/5 Disposable ECG electrodes, oval-shaped 50x48mm dimensions,Silver/Silver Chlori Disposable ECG electrodes, oval-shaped 50x48mm dimensions,Silver/Silver Chloride(SSC) sensor and stainless steel snap. F9060/5 model is suitable for rest, long term, stress or Holter ECG recording, with a direct application onto the skin. The SSC sensor permits a reliable and stable recording. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids DRX Electrode, Electrocardiograph NA
27 08054242449976 F9024SSC2W F9024SSC2W Reusable peripheral clamp electrodes for ECG, 30x130mm clamp dimensions. F9024SS Reusable peripheral clamp electrodes for ECG, 30x130mm clamp dimensions. F9024SSC2W has features that make it absolutely reliable during signal recording with all different ECG devices on the market. The electrode metallic part is made of silver coated material, allowing a safe and clear signal transmission. FIAB peripheral electrodes, thanks to screw and clip connections, can be connected to all ECG devices and monitors with patient cable which have plug or snap connections. Two white clamp packaging.The product is latex-free and without Nickel. DRX Electrode, Electrocardiograph NA
28 08054242449921 F9053N/55 F9053N/55 Disposable ECG monitoring electrodes have features that make them abs Disposable ECG monitoring electrodes have features that make them absolutely reliable during long monitoring ECG recording (not longer than 72 hours). F9053N/55 model is oval-shaped electrodes, 30x23mm dimensions, equipped with 55cm long wire and 4mm socket, pre-gelled and it can be easily connected to the ECG monitor, avoiding pressure on the skin. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids. DRX Electrode, Electrocardiograph NA
29 08054242449914 F9053P/55 F9053P/55 Disposable ECG monitoring electrodes have features that make them abs Disposable ECG monitoring electrodes have features that make them absolutely reliable during long monitoring ECG recording (not longer than 72 hours). F9053P/55 model is round-shaped electrodes, Ø 32mm, equipped with 55cm long wire and 4mm socket, pre-gelled and it can be easily connected to the ECG monitor, avoiding pressure on the skin. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids. DRX Electrode, Electrocardiograph NA
30 08054242449808 F9070RM F9070RM F9070RM model is disposable ECG RADIOLUCENT electrode with solid gel, rou F9070RM model is disposable ECG RADIOLUCENT electrode with solid gel, round-shaped Ø 50mm, Silver/Silver Chloride (SSC) sensor and carbon snapThe SSC sensor permits a reliable and stable recording. The peculiar feature of the electrode is the carbon snap that makes it radiolucent. Neither of the components contains any ferromagnetic materials, therefore the electrodes are fully compatible with MRI applications. The electrodes are MRI tested for use up to 3 T electro-magnetic field. The use of the electrodes do not affect the safety and functioning of Magnetic Resonance Imaging Systems. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids DRX Electrode, Electrocardiograph NA
31 08054242449655 F9089P/100 F9089P/100 Disposable ECG pediatric electrodes with solid gel, 36x32mm dimension, Silver/Si Disposable ECG pediatric electrodes with solid gel, 36x32mm dimension, Silver/Silver Chloride(SSC) sensor and stainless steel snap. F9089P/100 model are suitable both for rest and stress or Holter ECG recording, with a direct application onto the skin. The SSC sensor permits a reliable and stable recording and permits the signal recovery after defibrillator discharge . The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids. DRX Electrode, Electrocardiograph NA
32 08054242449648 F9089/100 F9089/100 Disposable ECG electrodes with solid gel, 40x36mm dimension, Silver/Silver Chlor Disposable ECG electrodes with solid gel, 40x36mm dimension, Silver/Silver Chloride(SSC) sensor and stainless steel snap. F9089/100 model are suitable both for rest and stress or Holter ECG recording, with a direct application onto the skin. The SSC sensor permits a reliable and stable recording and permits the signal recovery after defibrillator discharge . The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids. DRX Electrode, Electrocardiograph NA
33 08054242449297 PG470/500/US PG470/500/US Disposable fully gelled ready to use electrodes, 35x45mm doime Disposable fully gelled ready to use electrodes, 35x45mm doimensions. PG470/500/US model is especially indicated in electrotherapy. High material flexibility permits to apply electrodes very easily on treating areas. Solid gel maintains unchanged the electrode adhesion and conductivity, during procedure. The products are Latex free GXY Electrode, Cutaneous NA
34 08054242449174 F9079P/100 F9079P/100 Disposable ECG electrodes with solid gel and SSC sensor, oval-shaped 32x36mm and Disposable ECG electrodes with solid gel and SSC sensor, oval-shaped 32x36mm and and stainless steel snap. F9079P/100 model is suitable both for rest and stress or Holter ECG recording, with a direct application onto the skin. The SSC sensor permits a reliable and stable recording. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids. DRX Electrode, Electrocardiograph NA
35 08054242449082 F9049/100 F9049/100 Disposable ECG electrodes, oval-shaped 48x34mm dimensions with solid gel, Disposable ECG electrodes, oval-shaped 48x34mm dimensions with solid gel, Silver/Silver Chloride (SSC) sensor and stainless steel snap. F9049/100 model is suitable for rest, long term, stress or Holter ECG recording, with a direct application onto the skin. The SSC sensor permits a reliable and stable recording. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids. DRX Electrode, Electrocardiograph NA
36 08054242448429 F9053PRRM/80 F9053PRRM/80 Disposable ECG monitoring electrodes have features that make them abs Disposable ECG monitoring electrodes have features that make them absolutely reliable during long monitoring ECG recording (not longer than 72 hours). F9053PRRM/80 model are oval-shaped electrodes, 20x15mm dimensions, equipped with 80cm long wire and 4mm socket, pre-gelled and they can be easily connected to the ECG monitor, avoiding pressure on the skin. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids.F9053PRRM/80 model is radiotranslucent, therefore it allows the user to perform radiographic procedures without removing the electrode. DRX Electrode, Electrocardiograph NA
37 08054242448184 F2080P F2080P Disposable ECG electrodes with solid gel, round-shaped Ø 40mm, Silver/Silver Ch Disposable ECG electrodes with solid gel, round-shaped Ø 40mm, Silver/Silver Chloride(SSC) sensor and stainless steel snap. F2080P model is is made of non woven fabric. The fabric is made of plastic polyethylene fiber (and not natural fiber) that guarantees the transpiration of the skin, but at the same time the resistance to liquids with which they may come into contact during their use. F2080P is suitable for rest, long term, stress or Holter ECG recording, with a direct application onto DRX Electrode, Electrocardiograph NA
38 08054242447934 F2080 F2080 Disposable ECG electrodes with solid gel, round-shaped Ø 55mm, Silver/Silver Ch Disposable ECG electrodes with solid gel, round-shaped Ø 55mm, Silver/Silver Chloride(SSC) sensor and stainless steel snap. F2080 model is is made of non woven fabric. The fabric is made of plastic polyethylene fiber (and not natural fiber) that guarantees the transpiration of the skin, but at the same time the resistance to liquids with which they may come into contact during their use. F2080 is suitable for rest, long term, stress or Holter ECG recording, with a direct application onto the skin. DRX Electrode, Electrocardiograph NA
39 08054242447859 PG477W/US PG477W/US PG477W/US are disposable adhesive electrodes with solid conductive gel. High mat PG477W/US are disposable adhesive electrodes with solid conductive gel. High material flexibility permits to apply electrodes very easily on treating areas. Solid gel maintains unchanged the electrode adhesion and conductivity, during procedure. The electrodes 75x140mm dimensions are equipped with a 10 cm long cable, with 2mm socket. The electrodes are passive devices serving as interface between transcutaneous neurostimulation devices and the patient’s skin. The electrodes are non-sterile and for single patient use only. Latex free. GXY Electrode, Cutaneous NA
40 08054242447842 PG479/32W/US PG479/32W/US PG479/32W/US are round-shaped disposable adhesive electrodes with solid conducti PG479/32W/US are round-shaped disposable adhesive electrodes with solid conductive gel. High material flexibility permits to apply electrodes very easily on treating areas. Solid gel maintains unchanged the electrode adhesion and conductivity, during procedure. The electrodes Ø 32mm are equipped with a 10 cm long cable, with 2mm socket. The electrodes are passive devices serving as interface between transcutaneous neurostimulation devices and the patient’s skin. The electrodes are non-sterile and for single patient use only. Latex free. GXY Electrode, Cutaneous NA
41 08054242447835 PG479/75W/US PG479/75W/US PG479/75W/US are round-shaped disposable adhesive electrodes with solid conducti PG479/75W/US are round-shaped disposable adhesive electrodes with solid conductive gel. High material flexibility permits to apply electrodes very easily on treating areas. Solid gel maintains unchanged the electrode adhesion and conductivity, during procedure. The electrodes Ø 75mm are equipped with a 10 cm long cable, with 2mm socket. The electrodes are passive devices serving as interface between transcutaneous neurostimulation devices and the patient’s skin. The electrodes are non-sterile and for single patient use only. Latex free. GXY Electrode, Cutaneous NA
42 08054242447828 PG479/50W/US PG479/50W/US PG479/50W/US are round-shaped disposable adhesive electrodes with solid conducti PG479/50W/US are round-shaped disposable adhesive electrodes with solid conductive gel. High material flexibility permits to apply electrodes very easily on treating areas. Solid gel maintains unchanged the electrode adhesion and conductivity, during procedure. The electrodes Ø 50 mm are equipped with a 10 cm long cable, with 2mm socket. The electrodes are passive devices serving as interface between transcutaneous neurostimulation devices and the patient’s skin. The electrodes are non-sterile and for single patient use only. Latex free. GXY Electrode, Cutaneous NA
43 08054242447811 PG471/50W/US PG471/50W/US PG471/50W/US are round shaped-disposable adhesive electrodes with solid conducti PG471/50W/US are round shaped-disposable adhesive electrodes with solid conductive gel. High material flexibility permits to apply electrodes very easily on treating areas. Solid gel maintains unchanged the electrode adhesion and conductivity, during procedure. The electrodes Ø 50mm are equipped with a 10 cm long cable, with 2mm socket. The electrodes are passive devices serving as interface between transcutaneous neurostimulation devices and the patient’s skin. The electrodes are non-sterile and for single patient use only. Latex free. GXY Electrode, Cutaneous NA
44 08054242447804 PG474W/US PG474W/US PG474W/US are disposable adhesive electrodes with solid conductive gel. High mat PG474W/US are disposable adhesive electrodes with solid conductive gel. High material flexibility permits to apply electrodes very easily on treating areas. Solid gel maintains unchanged the electrode adhesion and conductivity, during procedure. The electrodes 45x98mm dimensions are equipped with a 10 cm long cable, with 2mm socket. The electrodes are passive devices serving as interface between transcutaneous neurostimulation devices and the patient’s skin. The electrodes are non-sterile and for single patient use only. Latex free. GXY Electrode, Cutaneous NA
45 08054242447798 PG471W/US PG471W/US PG471W/US are disposable adhesive electrodes with solid conductive gel. High mat PG471W/US are disposable adhesive electrodes with solid conductive gel. High material flexibility permits to apply electrodes very easily on treating areas. Solid gel maintains unchanged the electrode adhesion and conductivity, during procedure. The electrodes 46x47mm dimensions are equipped with a 10 cm long cable, with 2mm socket. The electrodes are passive devices serving as interface between transcutaneous neurostimulation devices and the patient’s skin. The electrodes are non-sterile and for single patient use only. Latex free. GXY Electrode, Cutaneous NA
46 08054242446463 F9048 F9048 Disposable ECG electrodes with solid gel, 57x34mm dimensions, Silver/Silver Chl Disposable ECG electrodes with solid gel, 57x34mm dimensions, Silver/Silver Chloride(SSC) sensor and stainless steel snap. F9048 model is suitable both for rest and stress or Holter ECG recording, with a direct application onto the skin. The SSC sensor permits a reliable and stable recording. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids DRX Electrode, Electrocardiograph NA
47 08054242446456 U7755P U7755P Disposable multifunction electrodes for defibrillation, synchronized cardioversi Disposable multifunction electrodes for defibrillation, synchronized cardioversion, transcutaneous cardiac stimulation and ECG monitoring, with direct connection to cables and defibrillators, provided with radiotransparent pads and radio-opaque cable. Designed for direct connection to cables and defibrillators, they are characterized by a low impedance and a reduced stimulation threshold, with an excellent adaptability to the patient’s skin. The protective foam insulator and the safety plug eliminate every risk of electric micro-shock. Electrodes equipped with connector for defibrillators NIHON KOHDEN. Paediatric version. LDD Dc-Defibrillator, Low-Energy, (Including Paddles) 2 NA
48 08054242445916 F9053PR F9053PR Disposable ECG monitoring electrodes have features that make them abs Disposable ECG monitoring electrodes have features that make them absolutely reliable during long monitoring ECG recording (not longer than 72 hours). F9053PR model is oval-shaped electrodes, 20x15mm dimensions, equipped with 35cm long wire and 4mm socket, pre-gelled and they can be easily connected to the ECG monitor, avoiding pressure on the skin. The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids. DRX Electrode, Electrocardiograph NA
49 08054242446449 U7752P U7752P Disposable multifunction electrodes for defibrillation, synchronized cardioversi Disposable multifunction electrodes for defibrillation, synchronized cardioversion, transcutaneous cardiac stimulation and ECG monitoring, with direct connection to cables and defibrillators, provided with radiotransparent pads and radio-opaque cable. Designed for direct connection to cables and defibrillators, they are characterized by a low impedance and a reduced stimulation threshold, with an excellent adaptability to the patient’s skin. The protective foam insulator and the safety plug eliminate every risk of electric micro-shock. Electrodes equipped with connector for defibrillators PHYSIO-CONTROL. Paediatric version. LDD Dc-Defibrillator, Low-Energy, (Including Paddles) 2 NA
50 08054242446432 U7751P U7751P Disposable multifunction electrodes for defibrillation, synchronized cardioversi Disposable multifunction electrodes for defibrillation, synchronized cardioversion, transcutaneous cardiac stimulation and ECG monitoring, with direct connection to cables and defibrillators, provided with radiotransparent pads and radio-opaque cable. Designed for direct connection to cables and defibrillators, they are characterized by a low impedance and a reduced stimulation threshold, with an excellent adaptability to the patient’s skin. The protective foam insulator and the safety plug eliminate every risk of electric micro-shock. Electrodes equipped with connector for defibrillators ZOLL MEDICAL. Paediatric version. LDD Dc-Defibrillator, Low-Energy, (Including Paddles) 2 NA
Other products with the same Product Code "GEI"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 03700393301520 IC5330 IC5330 Single use, monopolar cautery scissors (curved blade) for laparoscopic surgery IN CUT scissors PETERS SURGICAL
2 03700393301445 IK5330 IK5330 Single use, monopolar cautery scissors (curved blade) for laparoscopic surgery IN CUT scissors PETERS SURGICAL
3 03700393301049 ECS5330 ECS5330 Single use, atraumatic Endoclinch forceps for laparoscopic surgery NA PETERS SURGICAL
4 03700393300899 MD5330 MD5330 Single use, Maryland dissector with monopolar cautery for laparoscopic surgery NA PETERS SURGICAL
5 03700393300783 H5330L H5330L Disposable hook with unipolar cautery for endoscopic surgery. NA PETERS SURGICAL
6 03700393300462 5053H 5053H Single use, blunt trocar for laparoscopic surgery NA PETERS SURGICAL
7 03700393300363 C5250 C5250 Single use, monopolar cautery scissors (curved blade) for laparoscopic surgery IN CUT scissors PETERS SURGICAL
8 03700393300325 CAB3000 CAB3000 single use, monopolar cable NA PETERS SURGICAL
9 03700393300301 11100S 11100S Single use, trocar with protected tip for laparoscopic surgery NA PETERS SURGICAL
10 03700393300288 12100H 12100H Single use, blunt trocar for laparoscopic surgery NA PETERS SURGICAL
11 03700393300264 12100 12100 Single use, sharp trocar for laparoscopic surgery NA PETERS SURGICAL
12 03700393300240 12060 12060 Single use, sharp trocar for laparoscopic surgery NA PETERS SURGICAL
13 03700393300226 5100 5100 Single use, sharp trocar for laparoscopic surgery NA PETERS SURGICAL
14 03700393300202 5068 5068 Single use, sharp trocar for laparoscopic surgery NA PETERS SURGICAL
15 03700393300189 5053 5053 Single use, sharp trocar for laparoscopic surgery NA PETERS SURGICAL
16 03700393300165 H5330 H5330 Single use, hook with monopolar cautery for laparoscopic surgery NA PETERS SURGICAL
17 03700393300141 G5330 G5330 Single use, grasping forceps with monopolar cautery for laparoscopic surgery NA PETERS SURGICAL
18 03700393300127 F5330 F5330 Single use, atraumatic forceps fenestrated with monopolar cautery for laparoscopic surgery NA PETERS SURGICAL
19 03700393300103 A5330 A5330 Single use, atraumatic forceps with monopolar cautery for laparoscopic surgery NA PETERS SURGICAL
20 03700393300080 D5330 D5330 Single use, dissector with monopolar cautery for laparoscopic surgery NA PETERS SURGICAL
21 03700393300066 T5330 T5330 Single use, monopolar cautery scissors (curved blade) for laparoscopic surgery IN CUT scissors PETERS SURGICAL
22 03700393300042 C5470 C5470 Single use, monopolar cautery scissors (curved blade) for laparoscopic surgery IN CUT scissors PETERS SURGICAL
23 03665772000091 B-1506 The monopolar hook are reusable (40 uses) endoscopic instrument. It is connected The monopolar hook are reusable (40 uses) endoscopic instrument. It is connected to the control handle and is used with the single-use Monopolar Protection sleeve (ref. M-1304). Each Arm is composed of an insulated shaft, a connection cover and an articulated instrument that provides distal mobility1. Tilting the tip with respect to the axis of the shaft2. Rotation of the tip around its own axis3. Opening-closing the tip/needle holder Arm Monopolar hook DEX SURGICAL
24 03665772000084 B-1505 The monopolar maryland are reusable (40 uses) endoscopic instrument. It is conne The monopolar maryland are reusable (40 uses) endoscopic instrument. It is connected to the control handle and is used with the single-use Monopolar Protection sleeve (ref. M-1304). Each Arm is composed of an insulated shaft, a connection cover and an articulated instrument that provides distal mobility1. Tilting the tip with respect to the axis of the shaft2. Rotation of the tip around its own axis3. Opening-closing the tip/needle holder Arm Monopolar Maryland DEX SURGICAL
25 03665772000077 B-1304 The monopolar scissors are reusable (20 uses) endoscopic instrument. It is conne The monopolar scissors are reusable (20 uses) endoscopic instrument. It is connected to the control handle and is used with the single-use Monopolar Protection sleeve (ref. M-1304). Each Arm is composed of an insulated shaft, a connection cover and an articulated instrument that provides distal mobility1. Tilting the tip with respect to the axis of the shaft2. Rotation of the tip around its own axis3. Opening-closing the tip/needle holder Arm Monopolar scissors DEX SURGICAL
26 03665772000060 B-1301 The arm needle holder is a reusable (40 uses) endoscopic instrument. It is conne The arm needle holder is a reusable (40 uses) endoscopic instrument. It is connected to the control handle and is used with the single-use Protection sleeve (ref. 2090-MDS). Each Arm is composed of a shaft, a connection cover and an articulated instrument followed by the needle holder tip that provides distal mobility.1. Tilting the tip with respect to the axis of the shaft2. Rotation of the tip around its own axis3. Opening-closing the tip/needle holder Arm Needle holder DEX SURGICAL
27 03665772000053 P46732 The Sleeve applicator tool purpose is to help the installation of Protection sle The Sleeve applicator tool purpose is to help the installation of Protection sleeve 2090-MDS onto the tip of Arm Needle holder B-1301 Sleeve applicator tool DEX SURGICAL
28 03665772000046 M-1304 Monopolar protection sleeve is designed to be installed onto Monopolar Arms B-13 Monopolar protection sleeve is designed to be installed onto Monopolar Arms B-1304, B-1505 and B-1506 and to remain there for the duration of the surgical procedure. It is provided non-sterile and is single use; it must be sterilize before the use. Its purpose is to protect the gear mechanism from its environment and guarantee the electrical insulation. It prevents the distal part of the arms (except for the tip) from coming into contact with the patient's tissues, thereby preventing the risk of lesions and burning subsequent to such contact. Monopolar protection sleeve DEX SURGICAL
29 03665772000039 2090-MDS Protection sleeve 2090-MDS is designed to be placed on the Needle holder arm and Protection sleeve 2090-MDS is designed to be placed on the Needle holder arm and to remain there for the duration of the surgical procedure. Its purpose is to protect the gear mechanism from its environment. It also helps prevent the gears from coming into contact with the patient's tissues, thereby preventing the risk of lesion formation subsequent to such mechanical contact. It is provided non-sterile and is single use; it must be sterilize before the use. Protection sleeve DEX SURGICAL
30 03665772000022 P-1302 The DEX Device control handle for left handed is comprised of an ergonomic hand The DEX Device control handle for left handed is comprised of an ergonomic hand piece that can turn on its own axis thanks to the comfort joint. This axis can also allow the user to perform a complete manual prono-supination movement without moving his shoulder.The control handle has command buttons that activate the different degrees of freedom or the Arm. The three axes are motorized: Open/Close, Tilt (Left/Right), Rotation+/Rotation-. Control Handle Left DEX SURGICAL
31 03665772000015 P-1301 The DEX Device control handle is comprised of an ergonomic hand piece that can t The DEX Device control handle is comprised of an ergonomic hand piece that can turn on its own axis thanks to the comfort joint. This axis can also allow the user to perform a complete manual prono-supination movement without moving his shoulder.The control handle has command buttons that activate the different degrees of freedom or the Arm. The three axes are motorized: Open/Close, Tilt (Left/Right), Rotation+/Rotation-. Control handle DEX SURGICAL
32 03665772000008 E-1301 The console or control unit contains the DEX Device operating system. The front The console or control unit contains the DEX Device operating system. The front surface contains indicator lights, buttons, an emergency stop button and a connection port Control Unit DEX SURGICAL
33 03596010648112 72202149S 72202149S SVCE REPL DYONICS RF GENERATOR DYONICS RF SMITH & NEPHEW, INC.
34 03596010625144 72202147 72202147 DYONICS RF CONTRACT 30 DEG DYONICS RF SMITH & NEPHEW, INC.
35 03596010625137 72202138 72202138 DYONICS RF-S DYNAMO 90 DEG DYONICS RF, DYNAMO SMITH & NEPHEW, INC.
36 03596010625120 72202140 72202140 DYONICS RF-S CROSS 50 DEG DYONICS RF, CROSS SMITH & NEPHEW, INC.
37 03596010625113 72202142 72202142 DYONICS RF BROADNOSE 90 DEG DYONICS RF, BROADNOSE SMITH & NEPHEW, INC.
38 03596010625106 72202148 72202148 DYONICS RF ROUND 60 DEG DYONICS RF, ROUND SMITH & NEPHEW, INC.
39 03596010625090 72202146 72202146 DYONICS RF SLICE 20 DEG DYONICS RF, SLICE SMITH & NEPHEW, INC.
40 03596010625083 72202143 72202143 DYONICS RF CURVE 45 DEG DYONICS RF, CURVE SMITH & NEPHEW, INC.
41 03596010625076 72202145 72202145 DYONICS RF HOOK 30 DEG DYONICS RF, HOOK SMITH & NEPHEW, INC.
42 03596010625069 72202144 72202144 DYONICS RF HEDGEHOG DYONICS RF, HEDGEHOG SMITH & NEPHEW, INC.
43 03596010625052 72202141 72202141 DYONICS RF ABLATION 90 DEG DYONICS RF, ABLATION SMITH & NEPHEW, INC.
44 03596010625045 72202139 72202139 DYONICS RF-S WHIRLWIND 90 DEG DYONICS RF, WHIRLWIND SMITH & NEPHEW, INC.
45 03596010625038 72202151 72202151 FOOT PEDAL DYONICS RF GENERATOR DYONICS RF SMITH & NEPHEW, INC.
46 03596010624949 72202149 72202149 DYONICS RF GENERATOR DYONICS RF, DYNAMO SMITH & NEPHEW, INC.
47 03596010615510 7205962 7205962 5.5 MM DYONICS BONECUTTER ELECTROBLADE, ORANG 5.5 MM DYONICS BONECUTTER ELECTROBLADE, ORANGE. RESECTOR COMPATIBLE WITH THE VULCAN GENERATOR REQUIRES THE VULCAN GENERATOR ADAPTER AND ERBE GENERATOR NA SMITH & NEPHEW, INC.
48 03596010615503 7210380 7210380 ELECTROBLADE GENERATOR ADAPTER REQUIRED TO OP ELECTROBLADE GENERATOR ADAPTER REQUIRED TO OPERATE 7205962, PACKAGED NON-STERILE, REUSABLE NA SMITH & NEPHEW, INC.
49 03596010613561 7210812F 7210812F VULCAN GENERATOR ONLY REFURBISHED CE MARK VULCAN SMITH & NEPHEW, INC.
50 03596010612793 72201356 72201356 PCMCIA CARD SOFTWARE VERSION 3.71 VULC VULCAN SMITH & NEPHEW, INC.