Other products from "HOLOGIC, INC."
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 15420045515031 2050-0104 2050-0104 MWP Cabinet, x-ray system 2 FAXITRON PATH
2 15420045514089 R15 R15 GDF GUIDE, NEEDLE, SURGICAL 1 PERL
3 15420045506909 Discovery C KGI Densitometer, bone 2 Discovey C
4 15420045504110 ATEC Sapphire 200 KNW INSTRUMENT, BIOPSY 2 ATEC Sapphire 200
5 15420045510333 50-250XL HIH HYSTEROSCOPE (AND ACCESSORIES) 2 MYOSURE XL HYSTEROSCOPY SET
6 15420045514294 V5 NSV5US-001 MNB Device, thermal ablation, endometrial 3 NovaSure
7 25420045510330 50-250XL HIH HYSTEROSCOPE (AND ACCESSORIES) 2 MYOSURE XL HYSTEROSCOPY SET
8 25420045514307 V5 NSV5KITUS-001 MNB Device, thermal ablation, endometrial 3 NovaSure
9 25420045505107 40-902 40-902 HIH HYSTEROSCOPE (AND ACCESSORIES) 2 MyoSure Tissue Removal Device
10 15420045514836 PATHVISION 23x29 PATHVISION23X29 MWP Cabinet, x-ray system 2 FAXITRON PATH
11 15420045514300 V5 NSV5KITUS-001 MNB Device, thermal ablation, endometrial 3 NovaSure
12 15420045512924 INTERNAL CONTROL-B, 960T, IVD PRD-06234 JJH CLINICAL SAMPLE CONCENTRATOR 1 Panther Fusion
13 15420045512917 EXTRACTION REAGENTS-B, 960T, IVD PRD-06232 JJH CLINICAL SAMPLE CONCENTRATOR 1 Panther Fusion
14 15420045510906 GBS CTRLS KIT, PANTHER FUSION, IVD PRD-04485 NJR Nucleic acid amplification assay system, group b streptococcus, direct specimen test 1 Panther Fusion
15 15420045510890 GBS KIT, 96T, IVD PRD-04484 NJR Nucleic acid amplification assay system, group b streptococcus, direct specimen test 1 Panther Fusion
16 15420045510470 INTERNAL CONTROL-X, 960T, IVD PRD-04476 NJR Nucleic acid amplification assay system, group b streptococcus, direct specimen test 1 Panther Fusion
17 15420045510463 EXTRACTION REAGENT-X, 960T, IVD PRD-04477 NJR Nucleic acid amplification assay system, group b streptococcus, direct specimen test 1 Panther Fusion
18 15420045509641 System Software InSight FD OXO Image-intensified fluoroscopic x-ray system, mobile 2 Flouroscan InSight
19 15420045509375 CLASS I CONTROL - C. ALBICANS PRD-04521 JJX Single (specified) analyte controls (assayed and unassayed) 1 aptima
20 15420045507937 20-401ML 20-401ML NWW Hysteroscope accessories Myosure Manual Tissue Removal Device
21 15420045505230 B90003 B90003 JAQ System, applicator, radionuclide, remote-controlled 2 4.0-5.0 CM CT LUMEN MARKER SET
22 15420045505193 B11245 B11245 JAQ System, applicator, radionuclide, remote-controlled 2 4-5 CM CONTURAFLEX MLB CATHETER w/TRI INTRODUCER
23 15420045505094 50-501XL 50-501XL HIH HYSTEROSCOPE (AND ACCESSORIES) MyoSure Tissue Removal Device
24 15420045505087 50-401XL 50-401XL HIH HYSTEROSCOPE (AND ACCESSORIES) 2 MyoSure Tissue Removal Device
25 15420045505070 30-401LITE 30-401LITE HIH HYSTEROSCOPE (AND ACCESSORIES) MyoSure Tissue Removal Device
26 15420045505001 919007-01 919007-01 JAQ System, applicator, radionuclide, remote-controlled Mammosite Variable 4-5 cm Applicator Tray
27 15420045504998 EVIVA_1213-20 EVIVA_1213-20 KNW INSTRUMENT, BIOPSY EVIVA_1213-20
28 15420045504950 EVIVA_0910-20 EVIVA_0910-20 KNW INSTRUMENT, BIOPSY EVIVA_0910-20
29 15420045504813 10-401 10-401 HIH HYSTEROSCOPE (AND ACCESSORIES) MyoSure Tissue Removal Device
30 15420045501140 2000 NS2000US MNB DEVICE, THERMAL ABLATION, ENDOMETRIAL NovaSure
31 15420045501133 2007 NS2007US MNB DEVICE, THERMAL ABLATION, ENDOMETRIAL NovaSure SureSound
32 15420045501126 2013 NS2013KITUS MNB DEVICE, THERMAL ABLATION, ENDOMETRIAL NovaSure SureSound
33 15420045501119 2013 NS2013US MNB DEVICE, THERMAL ABLATION, ENDOMETRIAL NovaSure
34 15420045501065 Cervista HTA System Computer MAQ KIT, DNA DETECTION, HUMAN PAPILLOMAVIRUS 3 Cervista HTA System
35 15420045500969 Cervista HTA System MAQ KIT, DNA DETECTION, HUMAN PAPILLOMAVIRUS 3 Cervista HTA System
36 15420045500952 Cervista HTA System MAQ KIT, DNA DETECTION, HUMAN PAPILLOMAVIRUS 3 Cervista HTA System
37 15420045500860 NovaSure Controller MNB DEVICE, THERMAL ABLATION, ENDOMETRIAL 3 NovaSure
38 15420045500853 NovaSure Controller MNB DEVICE, THERMAL ABLATION, ENDOMETRIAL 3 NovaSure
39 15420045512474 GENIUS AI DETECTION SOFTWARE OTE Digital breast tomosynthesis 3 GENIUS AI DETECTION
40 25420045510064 FILTER, THINPREP UROCYTE 100 PACK   70472-001 KET FILTERS, CELL COLLECTION, TISSUE PROCESSING ThinPrep
41 25420045510057 THINPREP SLIDES UROCYTE, 100 pk 70471-001 KEW SLIDES, MICROSCOPE ThinPrep
42 25420045509990 THINPREP MICROSCOPE, ARCLESS, 72pk 70126-002 KEW SLIDES, MICROSCOPE ThinPrep
43 25420045509679 NON-GYN Slides 70372-001 KEW SLIDES, MICROSCOPE ThinPrep
44 25420045509662 NON-GYN Filters, 100 pack 70205-001 KET FILTERS, CELL COLLECTION, TISSUE PROCESSING ThinPrep
45 25420045508467 UroCyte Vial 70473-001  LEA PRESERVATIVE, CYTOLOGICAL 1 ThinPrep
46 25420045505039 819001 819001 JAQ System, applicator, radionuclide, remote-controlled 2 Neucletron HDR Afterloader Connectors wObturators
47 15420045514775 PRESERVCYT VIAL PRD-07129 LEA PRESERVATIVE, CYTOLOGICAL 1 ThinPrep
48 15420045514621 UroCyte Vial ASY-15509 LEA PRESERVATIVE, CYTOLOGICAL 1 ThinPrep
49 15420045514614 CytoLyt Cup PRD-07065 LEA PRESERVATIVE, CYTOLOGICAL 1 ThinPrep
50 15420045514607 CytoLyt Tube PRD-07064 LEA PRESERVATIVE, CYTOLOGICAL 1 ThinPrep
Other products with the same Product Code "JAA"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 00195451000416 12.0x30mm L6IVL120030 The IVL Catheter is a proprietary lithotripsy device delivered through the perip The IVL Catheter is a proprietary lithotripsy device delivered through the peripheral arterial system of the lower extremities to the site of an otherwise difficult to treat calcified stenosis. Energizing the lithotripsy device will generate pulsatile mechanical energy within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. The IVL Catheter is comprised of an integrated balloon with an array of lithotripsy emitters for the localized delivery of pulsatile mechanical energy. The system consists of an IVL Catheter, an IVL Connector Cable and an IVL Generator. The IVL Catheter is available in four (4) sizes: 8.0 x 30mm, 9.0 x 30mm, 10.0 x 30mm, and 12.0 x 30mm. The L6 Peripheral IVL Catheter is compatible with a 7 or 8F sheath and has a working length of 110cm.The Shockwave L6 Peripheral IVL Catheter shaft contains an inflation lumen, a guidewire lumen, and the lithotripsy emitters. The inflation lumen is used for inflation and deflation of the balloon with 50/50 saline/contrast medium. The guidewire lumen enables the use of a 0.018” guidewire to facilitate advancement of the catheter to and through the target stenosis. The system is designed as ‘Over-the-wire’ (OTW) with 110cm shaft working length, so an exchange length (300cm) guidewire is indicated. The emitters are positioned along the length of the balloon working length for delivery of pulsatile mechanical energy. The balloon is located near the distal tip of the catheter. Two radiopaque marker bands within the balloon denote the length of the balloon to aid in positioning of the balloon during treatment. The balloon is designed to provide an expandable segment of known length and diameter at a specific pressure. The proximal hub has three ports: one for inflation/deflation of the balloon, one for guidewire lumen, and one for connection to the IVL Connector Cable. Shockwave Medical L6 Intravascular Lithotripsy (IVL) Catheter SHOCKWAVE MEDICAL, INC.
2 00195451000409 10.0x30mm L6IVL100030 The IVL Catheter is a proprietary lithotripsy device delivered through the perip The IVL Catheter is a proprietary lithotripsy device delivered through the peripheral arterial system of the lower extremities to the site of an otherwise difficult to treat calcified stenosis. Energizing the lithotripsy device will generate pulsatile mechanical energy within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. The IVL Catheter is comprised of an integrated balloon with an array of lithotripsy emitters for the localized delivery of pulsatile mechanical energy. The system consists of an IVL Catheter, an IVL Connector Cable and an IVL Generator. The IVL Catheter is available in four (4) sizes: 8.0 x 30mm, 9.0 x 30mm, 10.0 x 30mm, and 12.0 x 30mm. The L6 Peripheral IVL Catheter is compatible with a 7 or 8F sheath and has a working length of 110cm.The Shockwave L6 Peripheral IVL Catheter shaft contains an inflation lumen, a guidewire lumen, and the lithotripsy emitters. The inflation lumen is used for inflation and deflation of the balloon with 50/50 saline/contrast medium. The guidewire lumen enables the use of a 0.018” guidewire to facilitate advancement of the catheter to and through the target stenosis. The system is designed as ‘Over-the-wire’ (OTW) with 110cm shaft working length, so an exchange length (300cm) guidewire is indicated. The emitters are positioned along the length of the balloon working length for delivery of pulsatile mechanical energy. The balloon is located near the distal tip of the catheter. Two radiopaque marker bands within the balloon denote the length of the balloon to aid in positioning of the balloon during treatment. The balloon is designed to provide an expandable segment of known length and diameter at a specific pressure. The proximal hub has three ports: one for inflation/deflation of the balloon, one for guidewire lumen, and one for connection to the IVL Connector Cable. Shockwave Medical L6 Intravascular Lithotripsy (IVL) Catheter SHOCKWAVE MEDICAL, INC.
3 00195451000393 9.0x30mm L6IVL090030 The IVL Catheter is a proprietary lithotripsy device delivered through the perip The IVL Catheter is a proprietary lithotripsy device delivered through the peripheral arterial system of the lower extremities to the site of an otherwise difficult to treat calcified stenosis. Energizing the lithotripsy device will generate pulsatile mechanical energy within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. The IVL Catheter is comprised of an integrated balloon with an array of lithotripsy emitters for the localized delivery of pulsatile mechanical energy. The system consists of an IVL Catheter, an IVL Connector Cable and an IVL Generator. The IVL Catheter is available in four (4) sizes: 8.0 x 30mm, 9.0 x 30mm, 10.0 x 30mm, and 12.0 x 30mm. The L6 Peripheral IVL Catheter is compatible with a 7 or 8F sheath and has a working length of 110cm.The Shockwave L6 Peripheral IVL Catheter shaft contains an inflation lumen, a guidewire lumen, and the lithotripsy emitters. The inflation lumen is used for inflation and deflation of the balloon with 50/50 saline/contrast medium. The guidewire lumen enables the use of a 0.018” guidewire to facilitate advancement of the catheter to and through the target stenosis. The system is designed as ‘Over-the-wire’ (OTW) with 110cm shaft working length, so an exchange length (300cm) guidewire is indicated. The emitters are positioned along the length of the balloon working length for delivery of pulsatile mechanical energy. The balloon is located near the distal tip of the catheter. Two radiopaque marker bands within the balloon denote the length of the balloon to aid in positioning of the balloon during treatment. The balloon is designed to provide an expandable segment of known length and diameter at a specific pressure. The proximal hub has three ports: one for inflation/deflation of the balloon, one for guidewire lumen, and one for connection to the IVL Connector Cable. Shockwave Medical L6 Intravascular Lithotripsy (IVL) Catheter SHOCKWAVE MEDICAL, INC.
4 00195451000386 8.0x30mm L6IVL080030 The IVL Catheter is a proprietary lithotripsy device delivered through the perip The IVL Catheter is a proprietary lithotripsy device delivered through the peripheral arterial system of the lower extremities to the site of an otherwise difficult to treat calcified stenosis. Energizing the lithotripsy device will generate pulsatile mechanical energy within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. The IVL Catheter is comprised of an integrated balloon with an array of lithotripsy emitters for the localized delivery of pulsatile mechanical energy. The system consists of an IVL Catheter, an IVL Connector Cable and an IVL Generator. The IVL Catheter is available in four (4) sizes: 8.0 x 30mm, 9.0 x 30mm, 10.0 x 30mm, and 12.0 x 30mm. The L6 Peripheral IVL Catheter is compatible with a 7 or 8F sheath and has a working length of 110cm.The Shockwave L6 Peripheral IVL Catheter shaft contains an inflation lumen, a guidewire lumen, and the lithotripsy emitters. The inflation lumen is used for inflation and deflation of the balloon with 50/50 saline/contrast medium. The guidewire lumen enables the use of a 0.018” guidewire to facilitate advancement of the catheter to and through the target stenosis. The system is designed as ‘Over-the-wire’ (OTW) with 110cm shaft working length, so an exchange length (300cm) guidewire is indicated. The emitters are positioned along the length of the balloon working length for delivery of pulsatile mechanical energy. The balloon is located near the distal tip of the catheter. Two radiopaque marker bands within the balloon denote the length of the balloon to aid in positioning of the balloon during treatment. The balloon is designed to provide an expandable segment of known length and diameter at a specific pressure. The proximal hub has three ports: one for inflation/deflation of the balloon, one for guidewire lumen, and one for connection to the IVL Connector Cable. Shockwave Medical L6 Intravascular Lithotripsy (IVL) Catheter SHOCKWAVE MEDICAL, INC.
5 00195451000348 4.0x40mm S4IVLK4040 The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array o The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The distal catheter and balloon are hydrophilic coated to increase lubricity. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave S4 SHOCKWAVE MEDICAL, INC.
6 00195451000331 3.5x40mm S4IVLK3540 The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array o The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The distal catheter and balloon are hydrophilic coated to increase lubricity. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave S4 SHOCKWAVE MEDICAL, INC.
7 00195451000324 3.0x40mm S4IVLK3040 The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array o The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The distal catheter and balloon are hydrophilic coated to increase lubricity. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave S4 SHOCKWAVE MEDICAL, INC.
8 00195451000317 2.5x40mm S4IVLK2540 The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array o The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The distal catheter and balloon are hydrophilic coated to increase lubricity. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave S4 SHOCKWAVE MEDICAL, INC.
9 00195451000287 8.0x60mm M5PIVL8060 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
10 00195451000270 7.0x60mm M5PIVL7060 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
11 00195451000263 6.5x60mm M5PIVL6560 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
12 00195451000256 6.0x60mm M5PIVL6060 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
13 00195451000249 5.5x60mm M5PIVL5560 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
14 00195451000232 5.0x60mm M5PIVL5060 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
15 00195451000225 4.5x60mm M5PIVL4560 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
16 00195451000218 4.0x60mm M5PIVL4060 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
17 00195451000201 3.5x60mm M5PIVL3560 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
18 00195377108135 5050196 PULSE Array, Cios Left PULSE NUVASIVE, INC.
19 00195377108128 5050195 PULSE Array, Cios Right PULSE NUVASIVE, INC.
20 00195377081681 LNPULSENAVINS Pulse Loaner Nav Instrument Set PULSE NUVASIVE, INC.
21 00195377081674 LNPULSELRTABLET Pulse Loaner LessRay Tablet Set PULSE NUVASIVE, INC.
22 00195377081667 LNPULSELRGE9 Pulse Loaner LessRay GE 9in Set PULSE NUVASIVE, INC.
23 00195377081636 LNPULSELRBED Pulse Loaner LessRay Bed Array Set PULSE NUVASIVE, INC.
24 00195377081629 LNPULSEIOM Pulse Loaner IOM Set PULSE NUVASIVE, INC.
25 00195377081605 LNPULSEDRILLGUIDE Pulse Loaner Drill Guide PULSE NUVASIVE, INC.
26 00195377081490 LNPULSECAMCART Pulse Loaner Camera Cart Set PULSE NUVASIVE, INC.
27 00195377081483 LNPULSECAM Pulse Loaner Camera Set PULSE NUVASIVE, INC.
28 00195377065544 1802497 PULSE Software, v4.0.0-bln.eu PULSE NUVASIVE, INC.
29 00195377065537 1802495 PULSE Software, v4.0.0-bln.us PULSE NUVASIVE, INC.
30 00195377065520 1802493 PULSE Software, v4.0.0-bl.eu PULSE NUVASIVE, INC.
31 00195377065513 1802491 PULSE Software, v4.0.0-bl.us PULSE NUVASIVE, INC.
32 00195377065506 1802489 PULSE Software, Base Image PULSE NUVASIVE, INC.
33 00195377062406 PULSELRTABLET Pulse LessRay Tablet Set PULSE NUVASIVE, INC.
34 00195377062239 PULSEIOM Pulse IOM Set PULSE NUVASIVE, INC.
35 00195377062222 BETPULSEIOM Pulse IOM Set - BETA PULSE NUVASIVE, INC.
36 00195377061379 5000504 PULSE Camera PULSE NUVASIVE, INC.
37 00195377061331 1833072 PULSE Cart Power and Data Cable, Kit PULSE NUVASIVE, INC.
38 00195377061188 BETPULSELRTABLET Pulse LessRay Tablet Set - BETA PULSE NUVASIVE, INC.
39 00195377060723 PULSELRGE9 Pulse LessRay GE 9in Set PULSE NUVASIVE, INC.
40 00195377060716 PULSELRGE12 Pulse LessRay GE 12in Set PULSE NUVASIVE, INC.
41 00195377060709 PULSELRCIOS Pulse LR Cios Set PULSE NUVASIVE, INC.
42 00195377060693 PULSEDRLLGUIDEM Pulse Drill Guide Mesh Set PULSE NUVASIVE, INC.
43 00195377060686 PULSEDRILLGUIDE Pulse Drill Guide PULSE NUVASIVE, INC.
44 00195377060679 BETPULSENAVINSM2 Pulse Nav Instrument Mesh Set 2 - BETA PULSE NUVASIVE, INC.
45 00195377060662 BETPULSENAVINSM1 Pulse Nav Instrument Mesh Set 1 - BETA PULSE NUVASIVE, INC.
46 00195377060655 BETPULSELRGE9 Pulse LessRay GE 9in Set - BETA PULSE NUVASIVE, INC.
47 00195377060648 BETPULSELRGE12 Pulse LessRay GE 12in Set - BETA PULSE NUVASIVE, INC.
48 00195377060631 BETPULSELRCIOS Pulse LR Cios Set - BETA PULSE NUVASIVE, INC.
49 00195377060624 BETPULSEDRLLGUIDEM Pulse Drill Guide Mesh Set - BETA PULSE NUVASIVE, INC.
50 00195377060617 BETPULSEDRILLGUIDE Pulse Drill Guide - BETA PULSE NUVASIVE, INC.