No | Primary DI | Version or Model | Catalog Number | Device Description | Product Code | Product Code Name | Device Class | Brand Name |
---|---|---|---|---|---|---|---|---|
1 | 15099590704087 | B1017-435 | Neg Urine Combo 85 | LQM,LTW,LRG,JWY,LTT | Gram Negative Identification Panel,Susceptibility Test Cards, Antimicrobial,Inst Gram Negative Identification Panel,Susceptibility Test Cards, Antimicrobial,Instrument For Auto Reader & Interpretation Of Overnight Suscept. Systems,Manual Antimicrobial Susceptibility Test Systems,Panels, Test, Susceptibility, Antimicrobial | MicroScan | ||
2 | 15099590704070 | B1017-434 | Neg Urine Combo 84 | LQM,LTW,LRG,JWY,LTT | Gram Negative Identification Panel,Susceptibility Test Cards, Antimicrobial,Inst Gram Negative Identification Panel,Susceptibility Test Cards, Antimicrobial,Instrument For Auto Reader & Interpretation Of Overnight Suscept. Systems,Manual Antimicrobial Susceptibility Test Systems,Panels, Test, Susceptibility, Antimicrobial | MicroScan | ||
3 | 15099590765385 | C89645 | Neg Urine Combo 103 | JWY,LRG,LTT,LTW,LQM | Manual Antimicrobial Susceptibility Test Systems,Instrument For Auto Reader & In Manual Antimicrobial Susceptibility Test Systems,Instrument For Auto Reader & Interpretation Of Overnight Suscept. Systems,Panels, Test, Susceptibility, Antimicrobial,Susceptibility Test Cards, Antimicrobial,Gram Negative Identification Panel | 1 | MicroScan | |
4 | 15099590733919 | C48640 | Neg Urine Combo 90 | LQM,LTW,LTT,LRG,JWY | Gram Negative Identification Panel,Susceptibility Test Cards, Antimicrobial,Pane Gram Negative Identification Panel,Susceptibility Test Cards, Antimicrobial,Panels, Test, Susceptibility, Antimicrobial,Instrument For Auto Reader & Interpretation Of Overnight Suscept. Systems,Manual Antimicrobial Susceptibility Test Systems | MicroScan | ||
5 | 15099590707118 | DxA 5000 | DxA 5000 | JJE | Analyzer, Chemistry (Photometric, Discrete), For Clinical Use | 1 | DxA 5000 | |
6 | 15099590540210 | 6607098 | 6607098 | IMMUNO-TROL Low Cells | JPK | Mixture, Hematology Quality Control | 2 | IMMUNO-TROL Low Cells |
7 | 15099590250683 | 7546914 | 7546914 | COULTER LATRON Control | GKL | Counter, Cell, Automated (Particle Counter) | 2 | COULTER Latron |
8 | 15099590060206 | OSR6637 | Bicarbonate | KHS | Enzymatic, Carbon-Dioxide | 2 | AU | |
9 | 15099590222925 | 465980 | 465980 | Vigil Lipid Control Level 2 | JJY | Multi-Analyte Controls, All Kinds (Assayed) | 1 | Vigil |
10 | 15099590742751 | C69058 | C69058 | The Access SARS-CoV-2 IgG II Calibrators are intended to calibrate the Access SA The Access SARS-CoV-2 IgG II Calibrators are intended to calibrate the Access SARS-CoV-2 IgG II assay for the in vitro semi-quantitative and qualitative detection of SARS-CoV-2 IgG antibodies in human plasma (lithium heparin, dipotassium EDTA, tripotassium EDTA, and sodium citrate) for use on the Access Immunoassay Systems only.The Access SARS-CoV-2 IgG II calibrators are only for use under the Food and Drug Administration's Emergency Use Authorization. | QKO | Reagent, Coronavirus Serological | Access SARS-CoV-2 IgG II Calibrator | |
11 | 15099590701574 | C11478 | UniCel DxH 900 Coulter Cellular Analysis System | GKZ | Counter, Differential Cell | 2 | DxH 900 Hematology System | |
12 | 15099590672539 | B36633 | B36633 | CYTO-STAT /COULTER CLONE MsIgG2a-RD1 (Analyte Specific Reagent) | MVU | Reagents, Specific, Analyte | 1 | CYTO-STAT /COULTER CLONE MsIgG2a-RD1 |
13 | 15099590672522 | B36631 | B36631 | CYTO-STAT /COULTER CLONE Mo2-FITC (Analyte Specific Reagent) | MVU | Reagents, Specific, Analyte | 1 | CYTO-STAT /COULTER CLONE Mo2-FITC |
14 | 15099590672461 | B36623 | B36623 | CYTO-STAT /COULTER CLONE MsIgG2b-FITC (Analyte Specific Reagent) | MVU | Reagents, Specific, Analyte | 1 | CYTO-STAT /COULTER CLONE MsIgG2b-FITC |
15 | 15099590672454 | B36536 | B36536 | CYTO-STAT /COULTER CLONE B4-RD1 (Analyte Specific Reagent) | MVU | Reagents, Specific, Analyte | 1 | CYTO-STAT /COULTER CLONE B4-RD1 |
16 | 15099590663827 | 8448044 | 8448044 | COULTER Isoton III Diluent 20L | GIF | Diluent, Blood Cell | 1 | COULTER Isoton III Diluent |
17 | 15099590663803 | 8448177 | 8448177 | COULTER Lyse S III diff Lytic Reagent (5L) | GGK | Products, Red-Cell Lysing Products | 1 | COULTER Lyse S III diff Lytic Reagent |
18 | 15099590663797 | 8448155 | 8448155 | COULTER Lyse S III diff Lytic Reagent (1L) | GGK | Products, Red-Cell Lysing Products | 1 | COULTER Lyse S III diff Lytic Reagent |
19 | 15099590638191 | 378600 | 378600 | COULTER PrepPlus 2 | PER | Automated Pipetting, Diluting And Specimen Processing Workstations For Flow Cyto Automated Pipetting, Diluting And Specimen Processing Workstations For Flow Cytometric Analysis | 1 | PrepPlus 2 |
20 | 15099590625856 | 8546733 | 8546733 | COULTER Isoton III Diluent (20L) | GIF | Diluent, Blood Cell | 1 | COULTER Isoton III Diluent |
21 | 15099590625771 | 8547148 | 8547148 | COULTER Isoton 4 Diluent (20L) | GIF | Diluent, Blood Cell | 1 | COULTER Isoton 4 Diluent |
22 | 15099590624903 | A31590 | A31590 | The Access Toxo IgG QC is intended for monitoring system performance of the Acce The Access Toxo IgG QC is intended for monitoring system performance of the Access Toxo IgG assay. | LGD | Enzyme Linked Immunoabsorbent Assay, Toxoplasma Gondii | 2 | Access Toxo IgG QC |
23 | 15099590624811 | 33209 | 33209 | The Access CEA QC (BSA matrix) controls are intended for monitoring the system p The Access CEA QC (BSA matrix) controls are intended for monitoring the system performance of immunoenzymatic procedures for the quantitative measurement of Carcinoembryonic Antigen (CEA) using Access CEA reagents. | DHX | System, Test, Carcinoembryonic Antigen | 2 | Access CEA QC |
24 | 15099590583996 | Power Link | B05033 | Power Link | JJE | Analyzer, Chemistry (Photometric, Discrete), For Clinical Use | 1 | Power Link |
25 | 15099590572839 | UPS (CXP) | 626553 | Cytomics FC 500 with CXP Software | GKZ | Counter, Differential Cell | 2 | Cytomics FC500 |
26 | 15099590572822 | UPS (MPL) | 626554 | Cytomics FC 500 MPL with MXP Software | GKZ | Counter, Differential Cell | 2 | Cytomics FC500 |
27 | 15099590542863 | 6602940 | 6602940 | COULTER CLONE MsIgM-FITC | GKZ | Counter, Differential Cell | 2 | CC MsIgM-RD1 |
28 | 15099590542535 | 6602872 | 6602872 | COULTER CLONE MsIgG1 | GKZ | Counter, Differential Cell | 2 | CC MsIgG1 Isotypic Control |
29 | 15099590542511 | 6602884 | 6602884 | COULTER CLONE MsIgG1-RD1 | GKZ | Counter, Differential Cell | 2 | CC MsIgG1-RD1 |
30 | 15099590542399 | 6603838 | 6603838 | COULTER CLONE KC56 (T-200)-FITC (Analyte Specific Reagent) | MVU | Reagents, Specific, Analyte | 1 | COULTER CLONE KC56 (T-200)-FITC |
31 | 15099590542313 | 8547008 | 8547008 | IsoFlow Sheath Fluid | GIF | Diluent, Blood Cell | 1 | ISOFLOW SHEATH FLUID |
32 | 15099590541590 | 6602507 | 6602507 | COULTER CLONE Mo2-FITC | GKZ | Counter, Differential Cell | 2 | CC Mo2-FITC (CD14-FITC) |
33 | 15099590541378 | 6603822 | 6603822 | CYTO-STAT/COULTER CLONE 3A1-RD1 (Analyte Specific Reagent) | MVU | Reagents, Specific, Analyte | 1 | CYTO-STAT/COULTER CLONE 3A1-RD1 |
34 | 15099590541354 | 6603825 | 6603825 | COULTER CLONE 3A1-FITC (Analyte Specific Reagent) | MVU | Reagents, Specific, Analyte | 1 | COULTER CLONE 3A1-FITC |
35 | 15099590540951 | 6602381 | 6602381 | COULTER CLONE B1-FITC | GKZ | Counter, Differential Cell | 2 | CC B1-FITC (CD20-FITC) |
36 | 15099590540890 | 627808 | 627808 | FlowCARE PLG CD4 Reagent (CD45-FITC/CD4-PE) | GKZ | Counter, Differential Cell | 2 | FlowCARE PLG CD4 Reagent |
37 | 15099590540883 | 6603909 | 6603909 | CYTO-STAT/COULTER CLONE Mo2-RD1/KC56(T-200)-FITC | GKZ | Counter, Differential Cell | 2 | CS/CC Mo2-RD1/KC56(T-200)-FITC |
38 | 15099590540449 | 6607077 | 6607077 | IMMUNO-TROL Cells | JPK | Mixture, Hematology Quality Control | 2 | IMMUNO-TROL Cells |
39 | 15099590539757 | 6604500 | 6604500 | CYTO-STAT/COULTER CLONE Mo2-RD1 | GKZ | Counter, Differential Cell | 2 | CS/CC Mo2-RD1 (CD14-RD1) |
40 | 15099590539719 | 6604621 | 6604621 | CYTO-STAT/COULTER CLONE CD3(IgG1)-RD1 | GKZ | Counter, Differential Cell | 2 | CS/CC CD3(IgG1)-RD1 |
41 | 15099590539207 | 6602705 | 6602705 | COULTER CLONE NKH-1 (Analyte Specific Reagent) | MVU | Reagents, Specific, Analyte | 1 | COULTER CLONE NKH-1 |
42 | 15099590250973 | 8547196 | 8547196 | COULTER LH Series Retic Pak Reagent Kit | GGK | Products, Red-Cell Lysing Products | 1 | COULTER LH Series Retic Pak Reagent Kit |
43 | 15099590234089 | 721542 | 721542 | LH Series Cleaner (5L) | JCB | Detergent | 1 | LH Series Cleaner |
44 | 15099590250935 | 8546859 | 8546859 | IsoFlow Sheath Fluid | GIF | Diluent, Blood Cell | 1 | ISOFLOW SHEATH FLUID |
45 | 15099590250751 | 7547201 | 7547201 | COULTER TruColor Giemsa Stain | KQC | Stains, Hematology | 1 | COULTER TruColor Giemsa Stain |
46 | 15099590250720 | 7547180 | 7547180 | COULTER TruColor Wright Stain Buffer | KQC | Stains, Hematology | 1 | COULTER TruColor Wright Stain Buffer |
47 | 15099590250690 | 7546915 | 7546915 | COULTER LATRON Primer | GKL | Counter, Cell, Automated (Particle Counter) | 2 | COULTER Latron |
48 | 15099590233785 | 628028 | 628028 | COULTER Retic-X Cell Control | JPK | Mixture, Hematology Quality Control | 2 | COULTER Retic-X |
49 | 15099590233686 | 628017 | 628017 | COULTER DxH Diluent | GIF | Diluent, Blood Cell | 1 | COULTER DxH Diluent |
50 | 15099590232931 | 177017 | 177017 | QuickComp 4 Kit | GKZ | Counter, Differential Cell | 2 | QuickCOMP 4 Kit |
No | Primary DI | Version or Model | Catalog Number | Device Description | Brand Name | Organization Name |
---|---|---|---|---|---|---|
1 | 08809319396512 | 99LS10-2 | CURO L7 Lipid Test Strip - Lipid Profile | SD BIOSENSOR, INC. | ||
2 | 08809319396161 | 99LA10G-2 | CURO L7 Analyzer | SD BIOSENSOR, INC. | ||
3 | 08809115905413 | ILM-0001A | CURO L5 TC test strip | OSANG HEALTHCARE CO., LTD. | ||
4 | 08809115905406 | ILM-0001A | CURO L5 Meter | OSANG HEALTHCARE CO., LTD. | ||
5 | 07613336121115 | 08057443190 | 08057443190 | Cholesterol | ROCHE DIAGNOSTICS GMBH | |
6 | 05060500091859 | IR060-1200 | IR060-1200 | Cholesterol Reagent 6 X 67 mL + 3 X 54 mL | Synermed® | INFRARED LABORATORY SYSTEMS LLC |
7 | 05060500090623 | IR062-L | IR062-L | Cholesterol Enzyme Reagent 6 X 500 mL | Synermed® | INFRARED LABORATORY SYSTEMS LLC |
8 | 05060500090616 | IR061-L | IR061-L | Cholesterol Chromogen Reagent 6 X 1000 mL | Synermed® | INFRARED LABORATORY SYSTEMS LLC |
9 | 05060500090609 | IR060-911 | IR060-911 | Cholesterol Reagent 6 X 50 mL + 3 X 40 mL | Synermed® | INFRARED LABORATORY SYSTEMS LLC |
10 | 05060500090593 | IR060-WK | IR060-WK | Cholesterol Reagent 3 X 25 mL + 3 X 10 mL | Synermed® | INFRARED LABORATORY SYSTEMS LLC |
11 | 05060500090586 | IR060-X | IR060-X | Cholesterol Reagent 1 X 250 mL + 1 X 100 mL | Synermed® | INFRARED LABORATORY SYSTEMS LLC |
12 | 05060500090579 | IR060-R | IR060-R | Cholesterol Reagent 3 X 250 mL + 3 X 100 mL | Synermed® | INFRARED LABORATORY SYSTEMS LLC |
13 | 05055273208474 | CH8310 | For the quantitative in vitro determination of cholesterol in serum and plasma. | CHOLESTEROL (CHOL) | RANDOX LABORATORIES LIMITED | |
14 | 05055273208443 | CH8019 | CHOLESTEROL (CHOL) | RANDOX LABORATORIES LIMITED | ||
15 | 05055273201284 | CH3810 | CH3810 | For the quantitative in vitro determination of cholesterol in serum and plasma. | CHOL | RANDOX LABORATORIES LIMITED |
16 | 04571226470831 | 14-531 | 14-531 | Alere Cholestech LDX® Lipid Profile●GLU | Alere Cholestech LDX® | ALERE SAN DIEGO, INC. |
17 | 04015630924967 | 05168538190 | 05168538190 | Cholesterol Gen.2 | ROCHE DIAGNOSTICS GMBH | |
18 | 04015630922062 | 04718917190 | 04718917190 | Cholesterol Gen.2 | ROCHE DIAGNOSTICS GMBH | |
19 | 04015630918430 | 3039773190 | 03039773190 | Cholesterol Gen.2 | ROCHE DIAGNOSTICS GMBH | |
20 | 03610230006917 | 1300023838 | Yumizen C1200 Cholesterol | HORIBA ABX SAS | ||
21 | 03610230004975 | 1220001634 | ABX PENTRA CHOLESTEROL CP | HORIBA ABX SAS | ||
22 | 00899722002344 | 99021 | 99021 | Alere Cholestech LDX® Lipid Profile●GLU | Alere Cholestech LDX® | ALERE SAN DIEGO, INC. |
23 | 00899722002337 | 99020 | 99020 | Alere Cholestech LDX® Lipid Profile | Alere Cholestech LDX® | ALERE SAN DIEGO, INC. |
24 | 00893038002654 | 10-991 | 10-991 | Alere Cholestech LDX® Lipid Profile●GLU | Alere Cholestech LDX® | ALERE SAN DIEGO, INC. |
25 | 00893038002647 | 10-990 | 10-990 | Alere Cholestech LDX® TC●HDL●GLU | Alere Cholestech LDX® | ALERE SAN DIEGO, INC. |
26 | 00893038002630 | 10-989 | 10-989 | Alere Cholestech LDX® Lipid Profile | Alere Cholestech LDX® | ALERE SAN DIEGO, INC. |
27 | 00893038002623 | 10-988 | 10-988 | Alere Cholestech LDX® TC●GLU | Alere Cholestech LDX® | ALERE SAN DIEGO, INC. |
28 | 00893038002616 | 10-987 | 10-987 | Alere Cholestech LDX® TC●HDL | Alere Cholestech LDX® | ALERE SAN DIEGO, INC. |
29 | 00893038002609 | 10-986 | 10-986 | Alere Cholestech LDX® TC | Alere Cholestech LDX® | ALERE SAN DIEGO, INC. |
30 | EABA40000301 | 400-0030 | 400-0030 | The Piccolo® Lipid Panel Plus, used with the Piccolo® blood chemistry analyzer o The Piccolo® Lipid Panel Plus, used with the Piccolo® blood chemistry analyzer or the Piccolo Xpress® chemistry analyzer, is intended for the in vitro quantitative determination of total cholesterol (CHOL), high-density lipoprotein cholesterol (HDL), triglycerides (TRIG), alanine aminotransferase (ALT), aspartate aminotransferase (AST), and glucose (GLU) in capillary (fingerstick) lithium heparinized whole blood, venous lithium heparinized whole blood, lithium heparinized plasma, or serum in a clinical laboratory setting or point-of-care location. From the CHOL, HDL and TRIG determinations, low-density lipoprotein cholesterol (LDL), very low-density lipoprotein cholesterol (VLDL), non-HDL cholesterol, and a total cholesterol/high-density lipoprotein cholesterol ratio (TC/H) are calculated by the analyzer.Lipid measurements are used in the diagnosis and treatment of lipid and lipoprotein disorders, atherosclerosis, various liver and renal diseases, diabetes mellitus, and other diseases involving lipid metabolism or various endocrine disorders.The tests on this panel are waived under CLIA ’88 regulations. If a laboratory modifies the test system instructions, then the tests are considered high complexity and subject to all CLIA requirements. For CLIA waived labs, only lithium heparin whole blood (venous or capillary) may be tested. For use in moderate complexity labs, lithium heparinized whole blood, lithium heparinized plasma, or serum may be used. | Piccolo Lipid Panel Plus | ABAXIS, INC. |
31 | EABA40000251 | 400-0025 | 400-0025 | The Piccolo® Lipid Panel reagent disc, used with the Piccolo® blood chemistry an The Piccolo® Lipid Panel reagent disc, used with the Piccolo® blood chemistry analyzer or the Piccolo Xpress® Chemistry analyzer, is intended for the in vitro quantitative determination of total cholesterol (CHOL), high-density lipoprotein cholesterol (HDL), and triglycerides (TRIG) in capillary (fingerstick) lithium heparinized whole blood, venous lithium heparinized whole blood, lithium heparinized plasma, or serum in a clinical laboratory setting or point-of-care location. From these determinations low-density lipoprotein cholesterol (LDL), very low-density lipoprotein cholesterol (VLDL), non-HDL cholesterol, and a total cholesterol/high-density lipoprotein cholesterol ratio (TC/H) are calculated by the analyzer.Lipid measurements are used in the diagnosis and treatment of lipid and lipoprotein disorders, atherosclerosis, various liver and renal diseases, diabetes mellitus, and other diseases involving lipid metabolism or various endocrine disorders.This test is waived under CLIA ’88 regulations. If a laboratory modifies the test system instructions, then the test is considered high complexity and subject to all CLIA requirements. For CLIA waived labs, only lithium heparin whole blood (venous or capillary) may be tested. For use in moderate complexity labs, lithium heparinized whole blood, lithium heparinized plasma, or serum may be used. | Piccolo Lipid Panel | ABAXIS, INC. |
32 | 00860394001256 | CURO L5 Total Cholesterol Strips | Total Cholesterol Strips | CURO L5 Total Cholesterol Strips | KPI HEALTHCARE, INC. | |
33 | 00860394001225 | CURO L5 CURO L5 | CURO L5 Cholesterol and Glucose measuring system | CURO L5 | KPI HEALTHCARE, INC. | |
34 | 00857969006488 | SA1010 | SA1010 | Cholesterol Reagent | ACE | ALFA WASSERMANN, INC. |
35 | 00857969006440 | RX1010 | RX1010 | Cholesterol Reagent | ACE | ALFA WASSERMANN, INC. |
36 | 00852169008157 | CHL1100 | CHL1100 | In Vitro Diagnostics testing kit R1:4X60mL | ClearChem Diagnostics Inc. Cholesterol, Total | CLEARCHEM DIAGNOSTICS INC. |
37 | 00850014861346 | TD-4289 | HeartsCare C1 Total Cholesterol Test Strip (10pcs/box) | HEARTS BIO, INC. | ||
38 | 00850006113064 | Curo L5 | CURO L5 Glucose Strip | Curo L5 | KPI HEALTHCARE, INC. | |
39 | 00842768015090 | 10445143 | K1027 | Cholesterol Flex® reagent cartridge, 600 tests | Dimension Vista® Flex® reagent cartridge CHOL | SIEMENS HEALTHCARE DIAGNOSTICS INC. |
40 | 00842768005466 | 10444891 | DF27 | Cholesterol Flex® reagent cartridge, 480 tests | Dimension® Flex® reagent cartridge CHOL | SIEMENS HEALTHCARE DIAGNOSTICS INC. |
41 | 00817302024548 | ST211 | ST211 | Cholesterol (CHOL) Reagent | CAROLINA LIQUID CHEMISTRIES CORP.® CHOLESTEROL REAGENT KIT ST211 | CAROLINA LIQUID CHEMISTRIES CORPORATION |
42 | 00817302024401 | DT211 | DT211 | Cholesterol (CHOL) Reagent | CAROLINA LIQUID CHEMISTRIES CORP.® CHOLESTEROL REAGENT KIT DT211 | CAROLINA LIQUID CHEMISTRIES CORPORATION |
43 | 00817302024166 | BL211 | BL211 | Cholesterol (CHOL) | CAROLINA LIQUID CHEMISTRIES CORP.® CHOLESTEROL REAGENT KIT BL211 | CAROLINA LIQUID CHEMISTRIES CORPORATION |
44 | 00817302024067 | AU-211 | AU-211 | Cholesterol | CAROLINA LIQUID CHEMISTRIES CORP.® CHOLESTEROL REAGENT KIT AU-211 | CAROLINA LIQUID CHEMISTRIES CORPORATION |
45 | 00817302022360 | CC211 | CC211 | CHOL (Cholesterol) 2 x 300 tests | CAROLINA LIQUID CHEMISTRIES CORP.® CHOL CHOLESTEROL REAGENT CC211 | CAROLINA LIQUID CHEMISTRIES CORPORATION |
46 | 00817274021255 | CHO2-BUP | CHOLESTEROL PALS BULK (in 20 dry Liter bottles) | JAS Diagnostics | DREW SCIENTIFIC, INC. | |
47 | 00817274021248 | CHO2-1L | CHOLESTEROL LIQUID REAGENT (1x 1L) | JAS Diagnostics | DREW SCIENTIFIC, INC. | |
48 | 00817274021224 | CHO2-1LU | Cholesterol Liquid (1x 1L) UV | JAS Diagnostics | DREW SCIENTIFIC, INC. | |
49 | 00817274021217 | CHO2-125U | CHOLESTEROL LIQUID (1x 125mL) UV | JAS Diagnostics | DREW SCIENTIFIC, INC. | |
50 | 00817274021200 | DG-CHO2-1L | CHOLESTEROL LIQUID (1 x 1 Liter + 1 x 5 mL Standard) | JAS Diagnostics | DREW SCIENTIFIC, INC. |