| No | Primary DI | Version or Model | Catalog Number | Device Description | Product Code | Product Code Name | Device Class | Brand Name |
|---|---|---|---|---|---|---|---|---|
| 1 | 04250273714333 | VL PR 72-11 | M46445860 | FRN | Pump, Infusion | 2 | Volumat™ Line | |
| 2 | 00810020440713 | 4R2352 | 4R2352 | For Collection of Platelets with Optional Plasma. For Platelet Storage in Plasma For Collection of Platelets with Optional Plasma. For Platelet Storage in Plasma or Platelet Additive Solution Plus Plasma. For Use with the AMICUS Separator. | GKT | Separator, Automated, Blood Cell, Diagnostic | 2 | Amicus Double Needle Advanced Kit with Platelet Additive Solution Connector |
| 3 | 04086000856669 | Z074135 | Z074135 | Agilia Link 4 is an accessory to Agilia Infusion System as the stacking rack sys Agilia Link 4 is an accessory to Agilia Infusion System as the stacking rack system intended to power and organize four Agilia infusion pumps at the patient bedside. The Agilia Infusion System includes the Agilia Infusion Pump, which is a programmable electronic medical system dedicated to administering a pre-determined volume of an infusion product at a programmed rate, in combination with disposables and optional accessories. | MRZ | Accessories, Pump, Infusion | 2 | AGILIA LINK 4 US |
| 4 | 04086000101967 | 1.2 | Aurora Xi Plasmapheresis System Software Version 1.2 | GKT | Separator, Automated, Blood Cell, Diagnostic | 2 | Aurora Xi Plasmapheresis System | |
| 5 | 04086000101578 | 3.0 | X6S9830, X6S9830USB | DXT is intended to be used in blood establishments to facilitate networked commu DXT is intended to be used in blood establishments to facilitate networked communication between DXT compatible Fresenius Kabi apheresis devices andBECS or other Data Management Systems. | GKT | Separator, Automated, Blood Cell, Diagnostic | 2 | DXT Data Management System |
| 6 | 04086000101523 | 6R4612 | 6R4612 | For collection of plasma by membrane filtration.For Use With the Plasmacell Xi D For collection of plasma by membrane filtration.For Use With the Plasmacell Xi Disposable Sets. | GKT | Separator, Automated, Blood Cell, Diagnostic | 2 | Aurora Xi Plasmapheresis System |
| 7 | 04086000101387 | 4R2354 | 4R2354 | For Collection of Platelets with Optional Plasma. For Platelet Storage in Plasma For Collection of Platelets with Optional Plasma. For Platelet Storage in Plasma or Platelet Additive Solution Plus Plasma. For Use with the AMICUS Separator. Sterile Fluid Path. | GKT | Separator, Automated, Blood Cell, Diagnostic | 2 | Fenwal AMICUS Double Needle Advanced Kit |
| 8 | 04086000100199 | X4R5720 | X4R5720 | For Collection of Two Leukoreduced Red Blood Cell Products by Centrifugation. Fo For Collection of Two Leukoreduced Red Blood Cell Products by Centrifugation. For Use With the ALYX System. Sterile Fluid Path. | GKT | Separator, Automated, Blood Cell, Diagnostic | ALYX 2RBC LR KIT | |
| 9 | 04052682004193 | 4C2161 | 4C2161 | Y-Type Blood Component Recipient Set with Standard Blood Filter and Luer Adapter Y-Type Blood Component Recipient Set with Standard Blood Filter and Luer Adapter. Sterile Fluid Path | BRZ | Set, Blood Transfusion | 2 | Fenwal Y-Type Blood Comp. Recipient Set with Std. Blood Filter and Luer Adapter |
| 10 | 04052682004148 | 4C2160 | 4C2160 | Blood Component Recipient Set with Standard Blood Filter with Luer Adapter. Ster Blood Component Recipient Set with Standard Blood Filter with Luer Adapter. Sterile Fluid Path | BRZ | Set, Blood Transfusion | 2 | Fenwal Blood Comp. Recipient Set with Std. Blood Filter with Luer Adapter |
| 11 | 04052682000713 | 9108554 | 9108554 | ATV-70 Vacuum Line is a tubing system to connect:1. ATR 40/120 reservoir with ov ATV-70 Vacuum Line is a tubing system to connect:1. ATR 40/120 reservoir with overfill protector 2. ATR 40/120 reservoir with vacuum regulator of external vacuum source 3. Smoke filter with hydrophobic filter | CAC | Apparatus, Autotransfusion | 2 | ATV-70 Vacuum Line |
| 12 | 04052682000522 | 9006284 | 9006284 | Waste bag, 10 Liter, is a replacement waste bag to be used with the AT1 Autotran Waste bag, 10 Liter, is a replacement waste bag to be used with the AT1 Autotransfusion set. | GKT | Separator, Automated, Blood Cell, Diagnostic | Waste bag 10 l | |
| 13 | 04250273733860 | VL SP40-11 | M46445475 | For use with Agilia VP MC pumps / Volumat MC Agilia pump or gravity only. | FRN | Pump, Infusion | Volumat™ Line | |
| 14 | 04250273731965 | VL PR44-12 | M46445780 | FRN | Pump, Infusion | 2 | Volumat™ Line | |
| 15 | 04250273731941 | VL PR40-11 | M46445465 | FRN | Pump, Infusion | 2 | Volumat™ Line | |
| 16 | 04250273731903 | VL ST10-X0 | M46441375 | FRN | Pump, Infusion | 2 | Volumat™ Line | |
| 17 | 04250273731880 | VL SL00-X0 | M77460051 | FRN | Pump, Infusion | 2 | Volumat™ Line | |
| 18 | 04250273731866 | VL ON72-X1 | M46444175 | FRN | Pump, Infusion | 2 | Volumat™ Line | |
| 19 | 04250273731842 | VL ST02-X0 | M46441985 | FRN | Pump, Infusion | 2 | Volumat™ Line | |
| 20 | 04250273714838 | VL SP 62-1 | M46443450 | FRN | Pump, Infusion | 2 | Volumat™ Line | |
| 21 | 04250273714517 | VL ST 10-0 | M46441360 | FRN | Pump, Infusion | Volumat™ Line | ||
| 22 | 04250273714494 | VL PA 92-1 | M46445260 | FRN | Pump, Infusion | 2 | Volumat™ Line | |
| 23 | 04250273714470 | VL SL 00-0 | M77460030 | FRN | Pump, Infusion | 2 | Volumat™ Line | |
| 24 | 04250273714456 | VL TR 00-0 | M46442860 | FRN | Pump, Infusion | 2 | Volumat™ Line | |
| 25 | 04250273714432 | VL PR 42-41 | M46445680 | FRN | Pump, Infusion | 2 | Volumat™ Line | |
| 26 | 04250273714395 | VL ON 72-1 | M46444160 | FRN | Pump, Infusion | 2 | Volumat™ Line | |
| 27 | 04250273714371 | VL PN 02-1 | M46442460 | FRN | Pump, Infusion | 2 | Volumat™ Line | |
| 28 | 04250273714357 | VL PR 42-12 | M46445690 | FRN | Pump, Infusion | 2 | Volumat™ Line | |
| 29 | 04250273714319 | VL PA 92-2 | M46445270 | FRN | Pump, Infusion | 2 | Volumat™ Line | |
| 30 | 04250273714296 | VL PR 42-21 | M46445670 | FRN | Pump, Infusion | 2 | Volumat™ Line | |
| 31 | 04250273714258 | VL PR 42-11 | M46445660 | FRN | Pump, Infusion | 2 | Volumat™ Line | |
| 32 | 04250273714234 | VL PR 22-1 | M46445460 | FRN | Pump, Infusion | 2 | Volumat™ Line | |
| 33 | 04250273714180 | VL SP 22-0 | M46443160 | FRN | Pump, Infusion | 2 | Volumat™ Line | |
| 34 | 14052682004169 | 4C2243 | 4C2243 | Plasma Transfer Sets with Two Spikes. Sterile Fluid Path | KSB | Set, Transfer (Blood/Plasma) | Fenwal Plasma Transfer Sets with Two Spikes | |
| 35 | 04250273733884 | VL SL00-XP | M77460052 | For use with the Volumat primary lines. | FRN | Pump, Infusion | 2 | Volumat™ Line |
| 36 | 00810020440300 | Version 2.1C | X6S4021USB | AURORA Software Version 2.1C for collection of plasma by membrane filtration. | GKT | Separator, Automated, Blood Cell, Diagnostic | Aurora Software Version 2.1C Upgrade | |
| 37 | 04086000856089 | Z019735 | Z019735 | The Agilia VP Infusion System is intended for adult and pediatric care for the i The Agilia VP Infusion System is intended for adult and pediatric care for the intermittent or continuous delivery of parenteral fluids, medications, blood and blood derivatives through clinically accepted parenteral routes of administration. These routes of administration include intravenous, intra-arterial, subcutaneous and intraosseous using dedicated administration sets. The Agilia VP Infusion System is also intended for neonatal care for the intermittent or continuous delivery of parenteral fluids for hydration and nutrition, blood and blood derivatives through clinically accepted parenteral routes of administration. These routes of administration include intravenous, intra-arterial, and subcutaneous using dedicated administration sets. It is intended for use by trained healthcare professionals in healthcare facilities. | FRN | Pump, Infusion | 2 | AGILIA VP MC WIFI US |
| 38 | 04086000856058 | Z018735 | Z018735 | The Agilia SP Infusion System is intended for adult and pediatric care for the i The Agilia SP Infusion System is intended for adult and pediatric care for the intermittent or continuous delivery of parenteral fluids, medication, blood, and blood derivatives through clinically accepted parenteral routes of administration. These routes of administration include intravenous, intra-arterial, subcutaneous, and intraosseous using dedicated administration sets. The Agilia SP Infusion System is also intended for neonatal care for the intermittent or continuous delivery of parenteral fluids for hydration and nutrition, medication, blood, and blood derivatives through clinically accepted parenteral routes of administration and critical drugs under specific conditions. These routes of administration include intravenous, intraarterial, and subcutaneous using dedicated administration sets. It is intended for use by trained healthcare professionals in healthcare facilities | FRN | Pump, Infusion | 2 | AGILIA SP MC WIFI US |
| 39 | 04086000101455 | 4R2252 | 4R2252 | For Collection of Plasma by Membrane Filtration. For Use with the AUTOPHERESIS-C For Collection of Plasma by Membrane Filtration. For Use with the AUTOPHERESIS-C Instrument. Sterile Fluid Path. | GKT | Separator, Automated, Blood Cell, Diagnostic | Fenwal PLASMACELL-C Disposable Set | |
| 40 | 04086000100960 | X6R2302 | X6R2302 | AMICUS Apheresis Kit – Double Needle with Platelet Additive Solution Connector | GKT | Separator, Automated, Blood Cell, Diagnostic | 2 | AMICUS Apheresis Kit – Double Needle with Platelet Additive Solution Connector |
| 41 | 04086000100236 | 6R4601 | 6R4601 | Automated plasmapheresis system designed to collect virtually cell-free plasma b Automated plasmapheresis system designed to collect virtually cell-free plasma by membrane filtration using single-use disposable sets. Collected plasma is to be processed as Source Plasma. | GKT | Separator, Automated, Blood Cell, Diagnostic | 2 | Aurora Plasmapheresis System |
| 42 | 04086000100175 | X6R2350 | X6R2350 | Sterile Fluid Path. | GKT | Separator, Automated, Blood Cell, Diagnostic | Plastic Storage Container | |
| 43 | 04086000100144 | X6R2326 | X6R2326 | For Mononuclear Cell (MNC) Collection. For use with the AMICUS separator. Steril For Mononuclear Cell (MNC) Collection. For use with the AMICUS separator. Sterile Fluid Path. | GKT | Separator, Automated, Blood Cell, Diagnostic | Amicus MNC Apheresis Kit - Double Needle | |
| 44 | 04052682058912 | Z073607 | Z073607 | Agilia Duo is an accessory to Agilia Infusion System as the stacking rack system Agilia Duo is an accessory to Agilia Infusion System as the stacking rack system intended to power and organize two Agilia infusion pumps at the patient bedside. The Agilia Infusion System includes the Agilia Infusion Pump, which is a programmable electronic medical system dedicated to administering a pre-determined volume of an infusion product at a programmed rate, in combination with disposables and optional accessories. | MRZ | Accessories, Pump, Infusion | 2 | AGILIA DUO US |
| 45 | 04052682004254 | 4R2422 | 4R2422 | Red Cell Freezing Pack 2000 mL | KSR | Container, Empty, For Collection & Processing Of Blood & Blood Components | 2 | Fenwal Red Cell Freezing Pack 2000 mL |
| 46 | 04052682000843 | 9104444 | 9104444 | ATF 120 Fast Start Kit is a kit, consisting of AT3, ATR 120 Autotransfusion rese ATF 120 Fast Start Kit is a kit, consisting of AT3, ATR 120 Autotransfusion reservoir and the ATS Suction Line. | CAC | Apparatus, Autotransfusion | 2 | ATF 120 Fast start kit with AT3 |
| 47 | 00810020440140 | 4R2354G | 4R2354G | For Collection of Platelets with Optional Plasma. For Platelet Storage in Plasma For Collection of Platelets with Optional Plasma. For Platelet Storage in Plasma or Platelet Additive Solution Plus Plasma. For Use with the AMICUS Separator. Sterile Fluid Path. | GKT | Separator, Automated, Blood Cell, Diagnostic | AMICUS Double Needle Advanced Kit with 20 mL Platelet Sampling System Assembly | |
| 48 | 14086000101414 | 4R2088P | 4R2088P | For processing and/or storage of blood or blood components. Sterile Fluid Path. | KSR | Container, Empty, For Collection & Processing Of Blood & Blood Components | Fenwal PlasmaLink Transfer-Pack Container with Luer Adapter and No Outlet Ports | |
| 49 | 14052682004213 | 4R2004 | 4R2004 | Quadruple Transfer Pack Container 150 mL with Coupler. Sterile Fluid Path | KSR | Container, Empty, For Collection & Processing Of Blood & Blood Components | Fenwal Quadruple Transfer Pack Container 150 mL with Coupler | |
| 50 | 14052682004121 | 4R2023 | 4R2023 | Transfer Pack Container 600 mL with Coupler. Sterile Fluid Path | KSR | Container, Empty, For Collection & Processing Of Blood & Blood Components | Fenwal Transfer Pack Container 600 mL with Coupler |
| No | Primary DI | Version or Model | Catalog Number | Device Description | Brand Name | Organization Name |
|---|---|---|---|---|---|---|
| 1 | 34987350731273 | TC*MP1 | TERUMO SAMPLING SITE COUPLER | TERUMO SAMPLING SITE COUPLER | TERUMO CORPORATION | |
| 2 | 19555240401332 | A200200 | A200200 | SEG is intended to aid extraction of a biological fluid sample from a segmented SEG is intended to aid extraction of a biological fluid sample from a segmented piece of tubing. | Segment Sampler (SEG) | ITL ASIA PACIFIC SDN. BHD. |
| 3 | 19555240400151 | A100150 | A100150 | DonorCare® Needle Guard is intended to aid in the prevention of accidental needl DonorCare® Needle Guard is intended to aid in the prevention of accidental needle stick injuries upon completion of blood collection procedures. | DonorCare® Needle Guard Large Channel | ITL ASIA PACIFIC SDN. BHD. |
| 4 | 19555240400137 | A100100 | A100100 | DonorCare Needle Guard is intended to aid in the prevention of accidental needle DonorCare Needle Guard is intended to aid in the prevention of accidental needle stick injuries upon completion of blood collection procedures. | DonorCare® Needle Guard Small Channel | ITL ASIA PACIFIC SDN. BHD. |
| 5 | 14086000903209 | 4C2405 | 4C2405 | Sampling Site Coupler | Sampling Site Coupler | FRESENIUS KABI AG |
| 6 | M74430001 | 3000 | HemoTemp II | BIOSYNERGY, INC. | ||
| 7 | 10888234002314 | 0066906 | 0066906 | Anti-IgG coated Indicator Red Cells are intended for use in Capture-P and Captur Anti-IgG coated Indicator Red Cells are intended for use in Capture-P and Capture-P Ready-Screen solid phase assays for the detection of IgG antibodies to platelets. Capture-P Indicator Red Cells are a suspension of red blood cells coated with rabbit anti-human IgG. The red blood cells are suspended in a buffered preservative solution to which chloramphenicol (0.25 mg/mL) , neomycin sulfate (0.1 mg/mL) and gentamycin sulfate (0.05 mg/mL) have been added as preservatives. | Capture-P Indicator Red Cells | IMMUCOR, INC. |
| 8 | 10888234002291 | 0066908 | 0066908 | Capture LISS is a low ionic solution containing glycine and the dye Bromocresol Capture LISS is a low ionic solution containing glycine and the dye Bromocresol Purple and the preservative sodium azide (0.1%). The reagent will turn from blue purple to sky blue or turquoise in the presence of normal human serum or plasma. | Capture LISS | IMMUCOR, INC. |
| 9 | 10888234002147 | 0006418 | 0006418 | Capture LISS is for use as a low ionic strength potentiator and sample addition Capture LISS is for use as a low ionic strength potentiator and sample addition indicator in Capture solid phase tests for the detection of antibodies. This product is the single 57 mL bottle version. | Capture LISS | IMMUCOR, INC. |
| 10 | 10888234001577 | 0066905 | 0066905 | Immucor’s Capture-P Positive Control Serum (Weak) and Capture-P Negative Control Immucor’s Capture-P Positive Control Serum (Weak) and Capture-P Negative Control Serum are run controls to be used in the Capture-P and Capture-P Ready-Screen Solid Phase assays. | Capture-P Positive Control Serum (Weak), Capture-P Negative Control Serum | IMMUCOR, INC. |
| 11 | 10888234001560 | 0066904 | 0066904 | Capture-P Solid Phase System is intended for use in the detection of antibodies Capture-P Solid Phase System is intended for use in the detection of antibodies to platelets. Capture-P Solid Phase System is designed to detect the unexpected antiplatelet antibodies (antibody screening test) in a patient or donor population. | Capture-P | IMMUCOR, INC. |
| 12 | 10888234001546 | 0066902 | 0066902 | Immucor’s Capture-R Positive Control Serum (Weak) and Capture-R Negative Control Immucor’s Capture-R Positive Control Serum (Weak) and Capture-R Negative Control Serum are run controls to be used in Capture-R Solid Phase Assays, including Capture-R Select, Capture-R Ready-Screen and Capture-R Ready-ID. Capture-R Positive Control Serum (Weak) contains antibodies to red blood cells and sodium azide added as a preservative. Capture-R Negative Control Serum contains no antibodies to red blood cells; sodium azide is added as a preservative. | Capture-R Positive Control Serum (Weak), Capture-R Negative Control Serum | IMMUCOR, INC. |
| 13 | 10888234001300 | 0066251 | 0066251 | Capture-P solid phase system is intended for use in the detection of antibodies Capture-P solid phase system is intended for use in the detection of antibodies to platelets. This is the five (5) microplate product. | Capture-P | IMMUCOR, INC. |
| 14 | 10888234001294 | 0066248 | 0066248 | The Capture-P Control set is composed of both negative and weak positive control The Capture-P Control set is composed of both negative and weak positive control material to control both the Capture-P and Capture-P Ready-Screen tests. | Capture-P Control set | IMMUCOR, INC. |
| 15 | 10888234001287 | 0066247 | 0066247 | Capture-P Ready-Screen solid phase system is used to detect IgG HLA and platelet Capture-P Ready-Screen solid phase system is used to detect IgG HLA and platelet specific antibodies to platelets. This is a single microplate product. | Capture-P Ready-Screen | IMMUCOR, INC. |
| 16 | 10888234001270 | 0066246 | 0066246 | Capture-P solid phase system is intended for use in the detection of antibodies Capture-P solid phase system is intended for use in the detection of antibodies to platelets. This is the single microplate product. | Capture-P | IMMUCOR, INC. |
| 17 | 10888234001256 | 0066240 | 0066240 | Capture-P Indicator Red Cells are part of both the Capture-P and Capture-P Ready Capture-P Indicator Red Cells are part of both the Capture-P and Capture-P Ready-Screen tests, and they are used to visualize the final reaction. | Capture-P Indicator Red Cells | IMMUCOR, INC. |
| 18 | 10888234001218 | 0066231 | 0066231 | Capture LISS is for use as a low ionic strength potentiator and sample addition Capture LISS is for use as a low ionic strength potentiator and sample addition indicator in Capture solid phase tests for the detection of antibodies. This product is the 57 mL bottle version with six bottles packaged. | Capture LISS | IMMUCOR, INC. |
| 19 | 10888234000587 | 0006420 | 0006420 | Capture LISS is for use as a low ionic strength potentiator and sample addition Capture LISS is for use as a low ionic strength potentiator and sample addition indicator in Capture solid phase tests for the detection of antibodies. This product is the 11.5 mL vial version with ten vials packaged. | Capture LISS | IMMUCOR, INC. |
| 20 | 10888234000570 | 0006419 | 0006419 | Capture LISS is for use as a low ionic strength potentiator and sample addition Capture LISS is for use as a low ionic strength potentiator and sample addition indicator in Capture solid phase tests for the detection of antibodies. This product is the 11.5 mL vial version with one vial packaged. | Capture LISS | IMMUCOR, INC. |
| 21 | 10888234000488 | 0005035 | 0005035 | Platelet Wash and Storage Solution (PWSS) is used to wash, suspend and store pla Platelet Wash and Storage Solution (PWSS) is used to wash, suspend and store platelets. The solution is provided in a 1 liter bag. | Platelet Wash and Storage Solution | IMMUCOR, INC. |
| 22 | 10852282007157 | STV6 | 7206-50 | A blood bag temperature monitor for use by health care providers to determine if A blood bag temperature monitor for use by health care providers to determine if blood or blood products have reached or exceeded the indication temperature. | Safe-T-Vue 6 | TEMPTIME CORPORATION |
| 23 | 10852282007140 | STV10 | 7201-50 | A blood bag temperature monitor for use by health care providers to determine if A blood bag temperature monitor for use by health care providers to determine if blood or blood products have reached or exceeded the indication temperature. | Safe-T-Vue 10 | TEMPTIME CORPORATION |
| 24 | 10758750006113 | MTS9680 | MTS9680 | MTS™ Incubator | MTS | MICRO TYPING SYSTEMS, INC |
| 25 | 10758750006106 | MTS9650 | MTS9650 | MTS™ Worktable (plastic rack to hold cards and samples) | MTS | MICRO TYPING SYSTEMS, INC |
| 26 | 10758750006090 | MTS9640 | MTS9640 | ID-TIPMASTER | MTS | MICRO TYPING SYSTEMS, INC |
| 27 | 10758750006069 | MTS9612 | MTS9612 | MTS DISPENSER 1.0ML | MTS | MICRO TYPING SYSTEMS, INC |
| 28 | 10758750006052 | MTS9610 | MTS9610 | MTS DISPENSER 0.5ML | MTS | MICRO TYPING SYSTEMS, INC |
| 29 | 09555240404084 | A100754 | A100754 | SampLok® Sampling Kit (SSK) - 20mL is used to transfers samples from blood bags SampLok® Sampling Kit (SSK) - 20mL is used to transfers samples from blood bags or other containers with sterile docking compatible tubing to vacuum containers for laboratory tests. | SampLok® Sampling Kit 20mL | ITL ASIA PACIFIC SDN. BHD. |
| 30 | 09555240403865 | A100752 | A100752 | SampLok® Sampling Kit (SSK): SSK-Mk3-35mL is used to transfer samples from blood SampLok® Sampling Kit (SSK): SSK-Mk3-35mL is used to transfer samples from blood bags or other containers with sterile docking compatible tubing to vacuum containers for laboratory tests. | SampLok® Sampling Kit 35mL | ITL ASIA PACIFIC SDN. BHD. |
| 31 | 09555240400734 | A100750 | A100750 | SampLok® Sampling Kit (SSK): SSK-Mk3-10mL is used to transfer samples from blood SampLok® Sampling Kit (SSK): SSK-Mk3-10mL is used to transfer samples from blood bags or other containers with sterile docking compatible tubing to vacuum containers for laboratory tests. | SampLok® Sampling Kit 10mL | ITL ASIA PACIFIC SDN. BHD. |
| 32 | 09555240400536 | A100740 | A100740 | SampLok® Sampling Kit (SSK): SSK-Mk2-16mL is used to transfer samples from blood SampLok® Sampling Kit (SSK): SSK-Mk2-16mL is used to transfer samples from blood bags or other containers with sterile docking compatible tubing to vacuum containers for laboratory tests. | SampLok® Sampling Kit 16mL | ITL ASIA PACIFIC SDN. BHD. |
| 33 | 08033928530276 | MacoPress Smart Smarter and DMS WIFI Module - with breaker module | MAC2.BI.WIFI | The MacoPress Smarter (MPS) and DMS consist of two parts: the MacoPress Smarter The MacoPress Smarter (MPS) and DMS consist of two parts: the MacoPress Smarter device and the DMS Management software. The MacoPress Smart is intended as an automated blood component separator used for blood component separation and preparation. With the use of the DMS software, the separation procedures can be programmed to collect data of manufacturer components that can then be recorded, stored and analyzed. | MacoPress Smarter | DELCON SRL |
| 34 | 08033928530269 | MacoPress Smart Smarter and DMS WIFI Module no breaker | MAC2.BR.WIFI | The MacoPress Smarter (MPS) and DMS consist of two parts: the MacoPress Smarter The MacoPress Smarter (MPS) and DMS consist of two parts: the MacoPress Smarter device and the DMS Management software. The MacoPress Smart is intended as an automated blood component separator used for blood component separation and preparation. With the use of the DMS software, the separation procedures can be programmed to collect data of manufacturer components that can then be recorded, stored and analyzed. | MacoPress Smarter | DELCON SRL |
| 35 | 08033928530252 | MacoPress Smart Smarter and DMS Ethernet Module - with breaker module | MAC2.BI.LAN | The MacoPress Smarter (MPS) and DMS consist of two parts: the MacoPress Smarter The MacoPress Smarter (MPS) and DMS consist of two parts: the MacoPress Smarter device and the DMS Management software. The MacoPress Smart is intended as an automated blood component separator used for blood component separation and preparation. With the use of the DMS software, the separation procedures can be programmed to collect data of manufacturer components that can then be recorded, stored and analyzed. | MacoPress Smarter | DELCON SRL |
| 36 | 08033928530245 | MacoPress Smart Smarter and DMS Ethernet Module - no breaker | MAC2.BR.LAN | The MacoPress Smarter (MPS) and DMS consist of two parts: the MacoPress Smarter The MacoPress Smarter (MPS) and DMS consist of two parts: the MacoPress Smarter device and the DMS Management software. The MacoPress Smart is intended as an automated blood component separator used for blood component separation and preparation. With the use of the DMS software, the separation procedures can be programmed to collect data of manufacturer components that can then be recorded, stored and analyzed. | MacoPress Smarter | DELCON SRL |
| 37 | 04086000903226 | 4R4414 | 4R4414 | Fenwal Plasma Extractor | Fenwal Plasma Extractor | FRESENIUS KABI AG |
| 38 | 04086000860581 | 9025571 | 9025571 | The CompoMat G5 / CompoMaster Net G5 System is intended as an automated blood co The CompoMat G5 / CompoMaster Net G5 System is intended as an automated blood component separator used for blood component separation and preparation. | CompoMaster Net G5 | FRESENIUS KABI AG |
| 39 | 04086000860475 | 9025561 | 9025561 | The CompoMat G5 / CompoMaster Net G5 System is intended as an automated blood co The CompoMat G5 / CompoMaster Net G5 System is intended as an automated blood component separator used for blood component separation and preparation.The CompoMat G5 can carry out almost all preparation methods and handle almost all blood bag systems, such as conventional double, triple and quadruple blood bag systems. | CompoMat G5 | FRESENIUS KABI AG |
| 40 | 03567051503210 | 9MPSBI485 | 9MPSBI485 | The MacoPress Smart (MPS) and DMS consist of two parts: the MacoPress Smart devi The MacoPress Smart (MPS) and DMS consist of two parts: the MacoPress Smart device and the DMS Management software. The MacoPress Smart is intended as an automated blood component separator used for blood component separation and preparation. With the use of the DMS software, the separation procedures can be programmed to collect data of manufacturer components that can then be recorded, stored and analyzed. | 9MPSBI485:MacoPress Smart and DMS RS485 Module-with breaker for main press | MACO PRODUCTIONS |
| 41 | 03567051503203 | 9MPSBR485 | 9MPSBR485 | The MacoPress Smart (MPS) and DMS consist of two parts: the MacoPress Smart devi The MacoPress Smart (MPS) and DMS consist of two parts: the MacoPress Smart device and the DMS Management software. The MacoPress Smart is intended as an automated blood component separator used for blood component separation and preparation. With the use of the DMS software, the separation procedures can be programmed to collect data of manufacturer components that can then be recorded, stored and analyzed. | 9MPSBR485: MacoPress Smart and DMS RS485 Module-no breaker | MACO PRODUCTIONS |
| 42 | 03567051503197 | 9MPSBRWIFI | 9MPSBRWIFI | The MacoPress Smart (MPS) and DMS consist of two parts: the MacoPress Smart dev The MacoPress Smart (MPS) and DMS consist of two parts: the MacoPress Smart device and the DMS Management software. The MacoPress Smart is intended as an automated blood component separator used for blood component separation and preparation. With the use of the DMS software, the separation procedures can be programmed to collect data of manufacturer components that can then be recorded, stored and analyzed. | 9MPSBRWIFI-MacoPress Smart and DMS WiFi Module-no breaker | MACO PRODUCTIONS |
| 43 | 03567051503180 | 9MPSBRLAN | 9MPSBRLAN | The MacoPress Smart (MPS) and DMS consist of two parts: the MacoPress Smart devi The MacoPress Smart (MPS) and DMS consist of two parts: the MacoPress Smart device and the DMS Management software. The MacoPress Smart is intended as an automated blood component separator used for blood component separation and preparation. With the use of the DMS software, the separation procedures can be programmed to collect data of manufacturer components that can then be recorded, stored and analyzed. | 9MPSBRLAN:MacoPress Smart and DMS Ethernet Module-no breaker | MACO PRODUCTIONS |
| 44 | 03567051503173 | 9MPSBIWIFI | 9MPSBIWIFI | The MacoPress Smart (MPS) and DMS consist of two parts: the MacoPress Smart devi The MacoPress Smart (MPS) and DMS consist of two parts: the MacoPress Smart device and the DMS Management software. The MacoPress Smart is intended as an automated blood component separator used for blood component separation and preparation. With the use of the DMS software, the separation procedures can be programmed to collect data of manufacturer components that can then be recorded, stored and analyzed. | 9MPSBIWIFI:MacoPress Smart and DMS WiFi Module-with breaker for main press | MACO PRODUCTIONS |
| 45 | 03567051503166 | 9MPSBILAN | 9MPSBILAN | The MacoPress Smart (MPS) and DMS consist of two parts: the MacoPress Smart devi The MacoPress Smart (MPS) and DMS consist of two parts: the MacoPress Smart device and the DMS Management software. The MacoPress Smart is intended as an automated blood component separator used for blood component separation and preparation. With the use of the DMS software, the separation procedures can be programmed to collect data of manufacturer components that can then be recorded, stored and analyzed. | 9MPSBILAN:MacoPress Smart and DMS Ethernet Module-w/breaker for main press | MACO PRODUCTIONS |
| 46 | 00880304681514 | 800-1007A | 800-1007A | GPS® III PLATELET CONCENTRATION SYSTEM | BIOMET BIOLOGICS, LLC | |
| 47 | 00880304681507 | 800-1004A | 800-1004A | GPS® III Platelet Concentration System | BIOMET BIOLOGICS, LLC | |
| 48 | 00880304681491 | 800-1003A | 800-1003A | GPS® III Platelet Concentration System | BIOMET BIOLOGICS, LLC | |
| 49 | 00880304681446 | 800-0517 | 800-0517 | Plasmax® Plus Plasma Concentration Kit | BIOMET BIOLOGICS, LLC | |
| 50 | 00880304641068 | 800-1006A | 800-1006A | GPS® III PLATELET CONCENTRATION SYSTEM | BIOMET BIOLOGICS, LLC |