Arrow(R) VPS(R) Access Kit for use with 4 Fr. Peripherally Inserted Central Veno
Arrow(R) VPS(R) Access Kit for use with 4 Fr. Peripherally Inserted Central Venous Catheter
Arrow(R) VPS(R) Access Kit for use with 5 Fr. Peripherally Inserted Central Veno
Arrow(R) VPS(R) Access Kit for use with 5 Fr. Peripherally Inserted Central Venous Catheter
Arrow-Howes(TM) Quad-Lumen Central Venous Catheterization Set with Blue FlexTip(
Arrow-Howes(TM) Quad-Lumen Central Venous Catheterization Set with Blue FlexTip(R) ARROWg+ard Blue(R) Catheter
FOZ
Catheter,intravascular,therapeutic,short-term less than 30 days
Arrowg+ard Blue(R) MAC(TM) Two-Lumen Central Venous Access Kit for use with 7.5
Arrowg+ard Blue(R) MAC(TM) Two-Lumen Central Venous Access Kit for use with 7.5 - 8 Fr. Catheters
NextStep(R) Antegrade Hemodialysis Catheterization Set Long-Term Access. Cathete
NextStep(R) Antegrade Hemodialysis Catheterization Set Long-Term Access. Catheter Length, Tip to Cuff: 42 cm
The SG 218 Aerosol Tee Adapter is intended for use in a ventilator, oxygen or BI
The SG 218 Aerosol Tee Adapter is intended for use in a ventilator, oxygen or BIPAP circuit. Dimensions: 22mm O.D. x 18mm I.D./22mm O.D. x 18mm I.D./22mm O.D Reusable.
Reducing Adapter for use in breathing/ventilator circuit. - 30mm I.D. x 22mm O.D
Reducing Adapter for use in breathing/ventilator circuit. - 30mm I.D. x 22mm O.D. Molded of polysulfone. Reusable.
Reducing Adapter for use in breathing/ventilator circuit. - 10mm O.D. x 22mm I.D
Reducing Adapter for use in breathing/ventilator circuit. - 10mm O.D. x 22mm I.D. Molded of polycarbonate. Reusable.
Reducing Adapter for use in breathing/ventilator circuit. 15mm ID x 22mm ID. M
Reducing Adapter for use in breathing/ventilator circuit. 15mm ID x 22mm ID. Molded of polystyrene butadiene. Single Patient Use.
General Adapter 10mm OD x 10mm OD. Fits components of neonatal ventilator circui
General Adapter 10mm OD x 10mm OD. Fits components of neonatal ventilator circuits/CPAP systems. Molded of polysulfone. Reusable.
Reducing Adapter for use in breathing/ventilator circuit. - 15mm O.D. x 22mm I.D
Reducing Adapter for use in breathing/ventilator circuit. - 15mm O.D. x 22mm I.D. Molded of polysulfone. Reusable.
Straight Connector - 15mm ID x 15mm ID. Fits components of pediatric ventilator
Straight Connector - 15mm ID x 15mm ID. Fits components of pediatric ventilator circuits. Molded of silicone rubber. Reusable.
Reducing Connector - 15mm ID x 10mm ID. Fits components of pediatric to neonatal
Reducing Connector - 15mm ID x 10mm ID. Fits components of pediatric to neonatal ventilator circuits. Molded of silicone rubber. Reusable.
Straight Connector - 10mm ID x 10mm ID. Fits components of neonatal ventilator c
Straight Connector - 10mm ID x 10mm ID. Fits components of neonatal ventilator circuits. Molded of silicone rubber. Reusable.
Reducing Connector - 22mm ID x 15mm ID. Fits components of adult ventilator circ
Reducing Connector - 22mm ID x 15mm ID. Fits components of adult ventilator circuits. Molded of silicone rubber. Reusable.
Reducing Adapter for use in breathing/ventilator circuit. - 22mm I.D. x 15mm I.D
Reducing Adapter for use in breathing/ventilator circuit. - 22mm I.D. x 15mm I.D/22mm O.D. Molded of polycarbonate. Reusable.
The KM 030 Disposable Connector with LCD Thermometer is intended for use in a ve
The KM 030 Disposable Connector with LCD Thermometer is intended for use in a ventilator circuit, or a heated aerosol circuit. The LCD thermometer gives approximate temperature readings only and is not a substitute for definitive temperature monitoring. Dimensions: 22mm O.D. x 22mm I.D. Single Patient Use. Molded of High Density Polyethylene.
KC 213-D Wye connector with (3) 22mm OD ports. Fits components of adult ventilat
KC 213-D Wye connector with (3) 22mm OD ports. Fits components of adult ventilator circuits. Single Patient Use.
KC 212-D Wye connector with one - 18mm ID/22mm OD nebulizer port x (3) 22mm OD p
KC 212-D Wye connector with one - 18mm ID/22mm OD nebulizer port x (3) 22mm OD ports. Fits components of adult ventilator circuits. Single Patient Use.
Reducing adapter for use in breathing/ventilator circuit. 22mm ID x 22mm OD. Mo
Reducing adapter for use in breathing/ventilator circuit. 22mm ID x 22mm OD. Molded of polystyrene butadiene. Single Patient Use.
General Adapter - 15mm ID/22mm OD x 15mm ID/22mm OD. Fits components of adult v
General Adapter - 15mm ID/22mm OD x 15mm ID/22mm OD. Fits components of adult ventilator circuits/CPAP systems. Molded of polystyrene butadiene. Single Patient Use.
KC 211-D Wye connector with one - 18mm ID/22mm OD nebulizer port x (3) 22mm OD p
KC 211-D Wye connector with one - 18mm ID/22mm OD nebulizer port x (3) 22mm OD ports. Fits components of adult ventilator circuits. Single Patient Use.
90 degree Elbow Connector with Barbed Port that fits 3/16" ID tubing - 15mm ID/2
90 degree Elbow Connector with Barbed Port that fits 3/16" ID tubing - 15mm ID/22mm OD x15mm OD. Molded of polycarbonate. Reusable.
90 degree Elbow Connector with Luer Lock Port - 15mm ID/22mm OD x15mm OD. Molde
90 degree Elbow Connector with Luer Lock Port - 15mm ID/22mm OD x15mm OD. Molded of polycarbonate. Reusable.
Reducing Adapter for use in breathing/ventilator circuit. - 15mm I.D./22mm O.D.
Reducing Adapter for use in breathing/ventilator circuit. - 15mm I.D./22mm O.D. x 30mm I.D. Molded of polyetherimide. Reusable.
Reducing Adapter for use in breathing/ventilator circuit. - 22mm O.D. x 30mm I.D
Reducing Adapter for use in breathing/ventilator circuit. - 22mm O.D. x 30mm I.D. Molded of polycarbonate. Reusable.
Reducing Adapter for use in breathing/ventilator circuit. - 22mm I.D. x 30mm O.D
Reducing Adapter for use in breathing/ventilator circuit. - 22mm I.D. x 30mm O.D. Molded of polycarbonate. Reusable.
Reducing Adapter for use in breathing/ventilator circuit. - 22mm I.D. x 30mm I.D
Reducing Adapter for use in breathing/ventilator circuit. - 22mm I.D. x 30mm I.D. Molded of polycarbonate. Reusable.
Reducing Adapter for use in breathing/ventilator circuit. - 22mm O.D. x 30mm O.D
Reducing Adapter for use in breathing/ventilator circuit. - 22mm O.D. x 30mm O.D. Molded of polycarbonate. Reusable.
BE 127-7.5-40 Wye Connector with (2) 22mm OD ports, (1) 15mm ID/22mm OD port, (1
BE 127-7.5-40 Wye Connector with (2) 22mm OD ports, (1) 15mm ID/22mm OD port, (1) 7.5mm ID temperature probe port, and (1) barbed pressure port. Fits components of adult ventilator circuits. Reusable.
BE 127-7.5 Wye Connector with (2) 22mm OD ports, (1) 15mm ID/22mm OD port and 7.
BE 127-7.5 Wye Connector with (2) 22mm OD ports, (1) 15mm ID/22mm OD port and 7.5mm temperature probe port. Fits components of adult ventilator circuits. Reusable.
BE 127-40 Wye Connector with (2) 22mm OD ports, (1) 15mm ID/22mm OD port and (1)
BE 127-40 Wye Connector with (2) 22mm OD ports, (1) 15mm ID/22mm OD port and (1) barbed pressure port. Fits components of adult ventilator circuits. Reusable.
BE 127 Wye Connector with (2) 22mm OD ports and (1) 15mm ID/22mm OD port. Fits c
BE 127 Wye Connector with (2) 22mm OD ports and (1) 15mm ID/22mm OD port. Fits components of adult ventilator circuits. Reusable.
The BE 125-1TD Tee Adapter is intended for use in a ventilator, oxygen or BIPAP
The BE 125-1TD Tee Adapter is intended for use in a ventilator, oxygen or BIPAP circuit. Can be used to easily add a monitoring device such as a temperature probe to the breathing circuit. Dimensions: 22mm O.D. x 22mm I.D. x 15mm I.D. Single Patient Use. Molded of High Density Polyethylene.
The BE 125-1T Tee Adapter is intended for use in a ventilator, oxygen or BIPAP c
The BE 125-1T Tee Adapter is intended for use in a ventilator, oxygen or BIPAP circuit. Dimensions: 22mm O.D. x 22mm I.D. x 15mm I.D./22mm O.D Reusable.
The BE 125-1 Tee Adapter is intended for use in a ventilator, oxygen or BIPAP ci
The BE 125-1 Tee Adapter is intended for use in a ventilator, oxygen or BIPAP circuit. Dimensions: 22mm O.D. x 22mm O.D. x 15mm I.D./22mm O.D Reusable.
The BE 125 Tee Adapter is intended for use in a ventilator, oxygen or BIPAP circ
The BE 125 Tee Adapter is intended for use in a ventilator, oxygen or BIPAP circuit. Dimensions: 22mm O.D. x 15mm I.D./22mm O.D. x 15mm O.D./22mm O.D Reusable.
Specialty Adapter - 22mm ID x 22mm OD Adapter for ventilator circuits/CPAP syste
Specialty Adapter - 22mm ID x 22mm OD Adapter for ventilator circuits/CPAP systems. Molded of polystyrene butadiene. Single Patient Use.
The BE 117-W Tee Adapter is intended for use in a ventilator, oxygen or BIPAP ci
The BE 117-W Tee Adapter is intended for use in a ventilator, oxygen or BIPAP circuit. Can be used to easily add a monitoring device such as a temperature probe to the breathing circuit. Dimensions: 22mm O.D. x 22mm I.D. x 15mm I.D./22mm O.D. Single Patient Use. Molded of High Density Polyethylene.
General Adapter - 22mm ID x 22mm ID adapter for use in breathing/ventilator circ
General Adapter - 22mm ID x 22mm ID adapter for use in breathing/ventilator circuit. Molded of polystyrene butadiene, Single Patient Use.
General Adapter - 22mm ID x 22mm ID adapter for use in breathing/ventilator circ
General Adapter - 22mm ID x 22mm ID adapter for use in breathing/ventilator circuit. Molded of polycarbonate. Reusable.
Swivel Adapter 22mm ID x 15mm ID/22mm OD. Specialty adapter for ventilator circu
Swivel Adapter 22mm ID x 15mm ID/22mm OD. Specialty adapter for ventilator circuits/CPAP systems. Swivels 360 degrees. Molded of polypropylene. Single Patient Use.
Straight Connector - 22mm ID x 22mm ID. Fits components of adult ventilator circ
Straight Connector - 22mm ID x 22mm ID. Fits components of adult ventilator circuits. Molded of silicone rubber. Reusable.
Tapered Connector - 22mm ID x 27mm ID. Fits components of adult ventilator circu
Tapered Connector - 22mm ID x 27mm ID. Fits components of adult ventilator circuits. Molded of silicone rubber. Reusable.
A device with a handle used to plug the end of an anesthesia circuit/breathing c
A device with a handle used to plug the end of an anesthesia circuit/breathing circuit at two possible locations: the Y-piece or the gas sampling elbow. The temporary plugging of the anesthesia breathing circuit allows anesthetic gases to be flushed from the anesthesia machine through the WAG (waste anesthetic gas) scavenging line by way of continuous oxygen/air flow rate over a set amount of time, or by activating the flush valve and applying positive bag pressure in repeated succession. This practice reduces the amount of anesthetic gas released into the operating room and thus reduces harmful gas exposure to operating room personnel and premature anesthetic gas exposure to patients during preoxygenation or mask induction.There is no patient contact as the plug must be removed before the breathing circuit can be attached to a mask, endo/naso-tracheal tube, or any other breathing device.