CODMAN HAKIM Valve Programmer, 100-240V, IEC NOTICE: Do not exceed the following
CODMAN HAKIM Valve Programmer, 100-240V, IEC NOTICE: Do not exceed the following transport and storage conditions. Temperature -40 DEGREES C - +60 DEGREES C Relative Humidity 10 Percent - 85 Percent Atmospheric Pressure 500hPa - 1060hPa
CODMAN HAKIM Programmable In-Line Valve with Platform and Unitized 120cm Distal
CODMAN HAKIM Programmable In-Line Valve with Platform and Unitized 120cm Distal Catheter. Programmable in steps of 10mm H2O (98 Pa): 30mm H2O to 200mm H2O (294 Pa - 1960 Pa) Includes: Ventricular Catheter 14cm, Stylet, Right Angle Adapter, Atrial Connector, Straight Connector, Priming Adapter and Information Manual.
CODMAN HAKIM Programmable Valve Micro II Valve Programmable in steps of 10mm H2O
CODMAN HAKIM Programmable Valve Micro II Valve Programmable in steps of 10mm H2O (98 Pa): 30mm H2O to 200mm H2O (294 Pa - 1960 Pa) Includes: Priming Adapter and Information Manual
CODMAN HAKIM Programmable Valve Cylindrical Valve with Proximal Connector and Un
CODMAN HAKIM Programmable Valve Cylindrical Valve with Proximal Connector and Unitized Barium Distal Catheter 120cm Programmable in steps of 10mm H2O (98Pa): 30mm H2O to 200mm H2O (294Pa-1960Pa) Includes: 14cm Ventricular Catheter, Stylet, Anchoring Clip and Information Manual
CODMAN HAKIM Programmable Valve In-Line Valve Only, .030 Inch Reinforced Platfor
CODMAN HAKIM Programmable Valve In-Line Valve Only, .030 Inch Reinforced Platform Operating Pressure: 30mm H2O to 200mm H2O programmable in steps of 10mm H2O Includes: Priming Adapter and Information Manual
CODMAN HAKIM Programmable Cylindrical Valve with Unitized 14mm Selker Reservoir.
CODMAN HAKIM Programmable Cylindrical Valve with Unitized 14mm Selker Reservoir. Programmable in steps of 10mm H2O (98 Pa): 30mm H2O to 200mm H2O (294 Pa - 1960 Pa) Includes: Information Manual.
CODMAN HAKIM Precision Fixed Pressure Valve In-Line Valve with Unitized Ventricu
CODMAN HAKIM Precision Fixed Pressure Valve In-Line Valve with Unitized Ventricular and Unitized Distal Catheter Operating Pressure: 130mm H2O Plus or Minus 10mm H2O (1274 Pa Plus or Minus 98 Pa) High Range Includes: Precision Valve, 9cm Unitized Ventricular Catheter, 120cm Unitized Peritoneal Catheter, Stylet, Right Angle Adapter, Priming Adapter and Information Manual
CODMAN HAKIM Precision Fixed Pressure Valve In-Line Valve with Unitized Ventricu
CODMAN HAKIM Precision Fixed Pressure Valve In-Line Valve with Unitized Ventricular and Unitized Distal Catheter Operating Pressure: 100mm H2O Plus or Minus 10mm H2O (980 Pa Plus or Minus 98 Pa) Medium High Range Includes: Precision Valve, 9cm Unitized Ventricular Catheter, 120cm Unitized Peritoneal Catheter, Stylet, Right Angle Adapter, Priming Adapter and Information Manual
CODMAN HAKIM Precision Fixed Pressure Valve In-Line Valve with Unitized Ventricu
CODMAN HAKIM Precision Fixed Pressure Valve In-Line Valve with Unitized Ventricular and Unitized Distal Catheter Operating Pressure: 70mm H2O Plus or Minus 10mm H2O (686 Pa Plus or Minus 98 Pa) Medium Low Range Includes: Precision Valve, 9cm Unitized Ventricular Catheter, 120cm Unitized Peritoneal Catheter, Stylet, Right Angle Adapter, Priming Adapter and Information Manual
CODMAN HAKIM Precision Fixed Pressure Valve In-Line Valve with Unitized Ventricu
CODMAN HAKIM Precision Fixed Pressure Valve In-Line Valve with Unitized Ventricular and Unitized Distal Catheter Operating Pressure: 40mm H2O Plus or Minus 10mm H2O (392 Pa Plus or Minus 98 Pa) Low Range Includes: Precision Valve, 9cm Unitized Ventricular Catheter, 120cm Unitized Peritoneal Catheter, Stylet, Right Angle Adapter, Priming Adapter and Information Manual
CODMAN HAKIM Precision Fixed Pressure Valve In-Line Valve with Unitized Ventricu
CODMAN HAKIM Precision Fixed Pressure Valve In-Line Valve with Unitized Ventricular and Unitized Distal Catheter Operating Pressure: 10mm H2O Plus or Minus 10mm H2O (98 Pa Plus or Minus 98 Pa) Very Low Range Includes: Precision Valve, 9cm Unitized Ventricular Catheter, 120cm Unitized Peritoneal Catheter, Stylet, Right Angle Adapter, Priming Adapter and Information Manual
CODMAN HAKIM Precision Fixed Pressure Valve Micro ll Valve with Unitized Ventric
CODMAN HAKIM Precision Fixed Pressure Valve Micro ll Valve with Unitized Ventricular and Unitized Distal Catheter Operating Pressure: 130mm H2O Plus or Minus 10mm H2O (1274 Pa Plus or Minus 98 Pa) High Range Includes: Precision Valve, 8.5cm Unitized Ventricular Catheter, 120cm Unitized Peritoneal Catheter, Stylet, Right Angle Adapter, Priming Adapter and Information Manual
CODMAN HAKIM Precision Fixed Pressure Valve Micro ll Valve with Unitized Ventric
CODMAN HAKIM Precision Fixed Pressure Valve Micro ll Valve with Unitized Ventricular and Unitized Distal Catheter Operating Pressure: 100mm H2O Plus or Minus 10mm H2O (980 Pa Plus or Minus 98 Pa) Medium High Range Includes: Precision Valve, 8.5cm Unitized Ventricular Catheter, 120cm Unitized Peritoneal Catheter, Stylet, Right Angle Adapter, Priming Adapter and Information Manual
CODMAN HAKIM Precision Fixed Pressure Valve Micro ll Valve with Unitized Ventric
CODMAN HAKIM Precision Fixed Pressure Valve Micro ll Valve with Unitized Ventricular and Unitized Distal Catheter Operating Pressure: 70mm H2O Plus or Minus 10mm H2O (686 Pa Plus or Minus 98 Pa) Medium Low Range Includes: Precision Valve, 8.5cm Unitized Ventricular Catheter, 120cm Unitized Peritoneal Catheter, Stylet, Right Angle Adapter, Priming Adapter and Information Manual
CODMAN HAKIM Precision Fixed Pressure Valve Micro ll Valve with Unitized Ventric
CODMAN HAKIM Precision Fixed Pressure Valve Micro ll Valve with Unitized Ventricular and Unitized Distal Catheter Operating Pressure: 40mm H2O Plus or Minus 10mm H2O (392 Pa Plus or Minus 98 Pa) Low Range Includes: Precision Valve, 8.5cm Unitized Ventricular Catheter, 120cm Unitized Peritoneal Catheter, Stylet, Right Angle Adapter, Priming Adapter and Information Manual
CODMAN HAKIM Precision Fixed Pressure Valve Micro ll Valve with Unitized Ventric
CODMAN HAKIM Precision Fixed Pressure Valve Micro ll Valve with Unitized Ventricular and Unitized Distal Catheter Operating Pressure: 10mm H2O Plus or Minus 10mm H2O (98 Pa Plus or Minus 98 Pa) Very Low Range Includes: Precision Valve, 8.5cm Unitized Ventricular Catheter, 120cm Unitized Peritoneal Catheter, Stylet, Right Angle Adapter, Priming Adapter and Information Manual
CODMAN HAKIM Programmable Cylindrical Valve with Integral Connectors and Unitize
CODMAN HAKIM Programmable Cylindrical Valve with Integral Connectors and Unitized Rickham Reservoir. Programmable in steps of 10mm H2O (98 Pa): 30mm H2O to 200mm H2O (294 Pa - 1960 Pa) Includes: 120cm Peritoneal Catheter, Ventricular Catheter 14cm, Stylet, Introducer, Priming Adapter and Information Manual
CODMAN HAKIM Programmable Valve Micro II Valve with Unitized 14mm Selker Reservo
CODMAN HAKIM Programmable Valve Micro II Valve with Unitized 14mm Selker Reservoir and Unitized Barium Distal Catheter, 120cm Programmable in steps of 10mm H2O (98 Pa): 30mm H2O to 200mm H2O (294 Pa - 1960 Pa) Includes: 14cm Ventricular Catheter, Stylet, Priming Adapter and Information Manual
CODMAN HAKIM Programmable In-Line with .030 Inch Reinforced Platform and Unitize
CODMAN HAKIM Programmable In-Line with .030 Inch Reinforced Platform and Unitized Distal Catheter 120cm. Programmable in steps of 10mm H2O (98Pa): 30mm H2O to 200mm H2O (294Pa-1960Pa) Includes: Ventricular Catheter 14cm, Stylet, Right Angle Adapter, Priming Adapter and Information Manual.
CODMAN HAKIM Programmable Micro Valve with Unitized Prechamber and Unitized Dist
CODMAN HAKIM Programmable Micro Valve with Unitized Prechamber and Unitized Distal Catheter 120cm. Programmable in steps of 10mm H2O (98Pa): 30mm H2O to 200mm H2O (294Pa-1960Pa) Includes: Ventricular Catheter 14cm, Stylet, Right Angle Adapter, Priming Adapter, Straight Connector and Information Manual.
CODMAN HAKIM Programmable Valve Micro II Valve with Prechamber Programmable in s
CODMAN HAKIM Programmable Valve Micro II Valve with Prechamber Programmable in steps of 10mm H2O (98 Pa): 30mm H2O to 200mm H2O (294 Pa - 1960 Pa) Includes: Priming Adapter and Information Manual
CODMAN HAKIM Programmable Valve Cylindrical Valve with Integral Connector(s) Pro
CODMAN HAKIM Programmable Valve Cylindrical Valve with Integral Connector(s) Programmable in steps of 10mm H2O (98 Pa): 30mm H2O to 200mm H2O (294 Pa - 1960 Pa) Includes: Programmable Valve, Introducer and Information Manual
CODMAN HAKIM Precision Fixed Pressure Valve MICRO II Valve with Unitized Single
CODMAN HAKIM Precision Fixed Pressure Valve MICRO II Valve with Unitized Single Dome Reservoir Operating Pressure: 10mm H2O Plus or Minus 10mm H2O (98 Pa Plus or Minus 98 Pa) Very Low Range Includes: Straight Connector, Priming Adapter and Information Manual
CODMAN HAKIM Precision Fixed Pressure Valve MICRO II Valve with Unitized Single
CODMAN HAKIM Precision Fixed Pressure Valve MICRO II Valve with Unitized Single Dome Reservoir Operating Pressure: 130mm H2O Plus or Minus 10mm H2O (1274 Pa Plus or Minus 98 Pa) High Range Includes: Straight Connector, Priming Adapter and Information Manual
CODMAN HAKIM Precision Fixed Pressure Valve MICRO II Valve with Unitized Single
CODMAN HAKIM Precision Fixed Pressure Valve MICRO II Valve with Unitized Single Dome Reservoir Operating Pressure: 100mm H2O Plus or Minus 10mm H2O (980 Pa Plus or Minus 98 Pa) Medium High Range Includes: Straight Connector, Priming Adapter and Information Manual
CODMAN HAKIM Precision Fixed Pressure Valve MICRO II Valve with Unitized Single
CODMAN HAKIM Precision Fixed Pressure Valve MICRO II Valve with Unitized Single Dome Reservoir Operating Pressure: 70mm H2O Plus or Minus 10mm H2O (686 Pa Plus or Minus 98 Pa) Medium Low Range Includes: Straight Connector, Priming Adapter and Information Manual
CODMAN HAKIM Precision Fixed Pressure Valve MICRO II Valve with Unitized Single
CODMAN HAKIM Precision Fixed Pressure Valve MICRO II Valve with Unitized Single Dome Reservoir Operating Pressure: 40mm H2O Plus or Minus 10mm H2O (392 Pa Plus or Minus 98 Pa) Low Range Includes: Straight Connector, Priming Adapter and Information Manual
CODMAN HAKIM Programmable Cylindrical Valve with Suture Tabs and Integral Connec
CODMAN HAKIM Programmable Cylindrical Valve with Suture Tabs and Integral Connectors Includes: Information Manual Programmable in steps of 10mm H2O (98 Pa): 30mm H2O to 200mm H2O (294 Pa - 1960 Pa) Includes: Information Manual
CODMAN HAKIM Programmable Valve with Single Dome Reservoir Programmable in steps
CODMAN HAKIM Programmable Valve with Single Dome Reservoir Programmable in steps of 10mm H2O (98 Pa): 30mm H2O to 200mm H2O (294 Pa - 1960 Pa) Includes: Programmable Valve, Connector, Priming Adapter and Information Manual
CODMAN HAKIM Precision Fixed Pressure Valve Cylindrical Valve with Proximal Conn
CODMAN HAKIM Precision Fixed Pressure Valve Cylindrical Valve with Proximal Connector and Unitized Barium Distal Catheter 120cm Operating Pressure: 130mm H2O Plus or Minus 10mm H2O (1274 Pa Plus or Minus 98 Pa) High Range Includes: 14cm Ventricular Catheter, Stylet, Anchoring Clip and Information Manual
CODMAN HAKIM Precision Fixed Pressure Valve Cylindrical Valve with Proximal Conn
CODMAN HAKIM Precision Fixed Pressure Valve Cylindrical Valve with Proximal Connector and Unitized Barium Distal Catheter 120cm Operating Pressure: 100mm H2O Plus or Minus 10mm H2O (980 Pa Plus or Minus 98 Pa) Medium High Range Includes: 14cm Ventricular Catheter, Stylet, Anchoring Clip and Information Manual
CODMAN HAKIM Precision Fixed Pressure Valve Cylindrical Valve with Proximal Conn
CODMAN HAKIM Precision Fixed Pressure Valve Cylindrical Valve with Proximal Connector and Unitized Barium Distal Catheter 120cm Operating Pressure: 70mm H2O Plus or Minus 10mm H2O (686 Pa Plus or Minus 98 Pa) Medium Low Range Includes: 14cm Ventricular Catheter, Stylet, Anchoring Clip and Information Manual
CODMAN HAKIM Precision Fixed Pressure Valve Cylindrical Valve with Proximal Conn
CODMAN HAKIM Precision Fixed Pressure Valve Cylindrical Valve with Proximal Connector and Unitized Barium Distal Catheter 120cm Operating Pressure: 40mm H2O Plus or Minus 10mm H2O (392 Pa Plus or Minus 98 Pa) Low Range Includes: 14cm Ventricular Catheter, Stylet, Anchoring Clip and Information Manual
CODMAN HAKIM Precision Fixed Pressure Valve Cylindrical Valve with Proximal Conn
CODMAN HAKIM Precision Fixed Pressure Valve Cylindrical Valve with Proximal Connector and Unitized Barium Distal Catheter 120cm Operating Pressure: 10mm H2O Plus or Minus 10mm H2O (98 Pa Plus or Minus 98 Pa) Very Low Range Includes: 14cm Ventricular Catheter, Stylet, Anchoring Clip and Information Manual
CODMAN HAKIM Programmable Valve Cylindrical Valve with Suture Tabs and Unitized
CODMAN HAKIM Programmable Valve Cylindrical Valve with Suture Tabs and Unitized Barium Distal Catheter, 120cm Programmable in steps of 10mm H2O (98 Pa): 30mm H2O to 200mm H2O (294 Pa - 1960 Pa) Includes: 14cm Ventricular, Stylet, Right Angle Adapter, Introducer, Straight Connector and Information Manual
CODMAN HAKIM Programmable Valve Right Angle Valve with .030 Inch Reinforced Plat
CODMAN HAKIM Programmable Valve Right Angle Valve with .030 Inch Reinforced Platform Programmable in steps of 10mm H2O (98 Pa): 30mm H2O to 200mm H2O (294 Pa - 1960 Pa) Includes: Priming Adapter and Information Manual
CODMAN HAKIM Precision Fixed Pressure Valve with Proximal Tubing and .060 Inch P
CODMAN HAKIM Precision Fixed Pressure Valve with Proximal Tubing and .060 Inch Platform Operating Pressure: 130mm H2O High Range Includes: HOLTER Type "B" Connector, Straight Connector, Priming Adapter and information Manual
CODMAN HAKIM Precision Fixed Pressure Valve with Proximal Tubing and .060 Inch P
CODMAN HAKIM Precision Fixed Pressure Valve with Proximal Tubing and .060 Inch Platform Operating Pressure: 100mm H2O Medium High Range Includes: HOLTER Type "B" Connector, Straight Connector, Priming Adapter and information Manual
CODMAN HAKIM Precision Fixed Pressure Valve with Proximal Tubing and .060 Inch P
CODMAN HAKIM Precision Fixed Pressure Valve with Proximal Tubing and .060 Inch Platform Operating Pressure: 40mm H2O Low Range Includes: HOLTER Type "B" Connector, Straight Connector, Priming Adapter and information Manual
CODMAN HAKIM Precision Fixed Pressure Valve with Proximal Tubing and .060 Inch P
CODMAN HAKIM Precision Fixed Pressure Valve with Proximal Tubing and .060 Inch Platform Operating Pressure: 10mm H2O Very Low Range Includes: HOLTER Type "B" Connector, Straight Connector, Priming Adapter and information Manual
CODMAN HAKIM Micro II Valve Precision Fixed Pressure Valve Operating Pressure: 1
CODMAN HAKIM Micro II Valve Precision Fixed Pressure Valve Operating Pressure: 130mm H2O Plus or Minus 10mm H2O (1274 Pa Plus or Minus 98 Pa) High Range Includes: Priming Adapter and Information Manual
CODMAN HAKIM Precision Fixed Pressure Valve Micro II Valve Operating Pressure: 1
CODMAN HAKIM Precision Fixed Pressure Valve Micro II Valve Operating Pressure: 100mm H2O Plus or Minus 10mm H2O (980 Pa Plus or Minus 98 Pa) Medium High Range Includes: Priming Adapter and Information Manual
CODMAN HAKIM Precision Fixed Pressure Valve Micro II Valve Operating Pressure: 7
CODMAN HAKIM Precision Fixed Pressure Valve Micro II Valve Operating Pressure: 70mm H2O Plus or Minus 10mm H2O (686 Pa Plus or Minus 98 Pa) Medium Low Range Includes: Priming Adapter and Information Manual
CODMAN HAKIM Precision Fixed Pressure Valve Micro II Valve Operating Pressure: 4
CODMAN HAKIM Precision Fixed Pressure Valve Micro II Valve Operating Pressure: 40mm H2O Plus or Minus 10mm H2O (392 Pa Plus or Minus 98 Pa) Low Range Includes: Priming Adapter and Information Manual
CODMAN HAKIM Micro II Valve Precision Fixed Pressure Valve Operating Pressure: 1
CODMAN HAKIM Micro II Valve Precision Fixed Pressure Valve Operating Pressure: 10mm H2O Plus or Minus 10mm H2O (98 Pa Plus or Minus 98 Pa) Very Low Range Includes: Priming Adapter and Information Manual
CODMAN HAKIM Programmable Valve Micro II Valve with Unitized Barium Distal Cathe
CODMAN HAKIM Programmable Valve Micro II Valve with Unitized Barium Distal Catheter, 120cm Programmable in steps of 10mm H2O (98 Pa): 30mm H2O to 200mm H2O (294 Pa - 1960 Pa) Includes: 14cm Ventricular Catheter, Stylet, Right Angle Adapter, Priming Adapter and Information Manual
CODMAN HAKIM Programmable Valve Micro II Valve Programmable in steps of 10mm H2O
CODMAN HAKIM Programmable Valve Micro II Valve Programmable in steps of 10mm H2O (98 Pa): 30mm H2O to 200mm H2O (294 Pa - 1960 Pa) Includes: Ventricular Catheter 14cm, Stylet, Peritoneal Catheter 120cm, Anchoring Clip, Priming Adapter and Information Manual
CODMAN HAKIM Programmable In-Line Valve Unitized 13.3cm Ventricular Catheter and
CODMAN HAKIM Programmable In-Line Valve Unitized 13.3cm Ventricular Catheter and Unitized 120cm Peritoneal Catheter Programmable in steps of 10mm H2O (98 Pa): 30mm H2O to 200mm H2O (294 Pa - 1960 Pa) Includes: Stylet, Right Angle Adapter, Introducer, 17 Ga Needle and Information Manual
The LiquoGuard 7 tube set consists of a tubing, stop cocks with luer locks, a dr
The LiquoGuard 7 tube set consists of a tubing, stop cocks with luer locks, a drainage bag with a reflux valve, adapters to ensure correct insertion into the pump, and a pressure sensor housing with two pressure transducers, a cable for connection to the pump and a sticker to attach the sensor housing to the patient's skin. The tube set is only for use with the LiquoGuard 7.
The LiquoGuard 7 tube set consists of a tubing, stop cocks with luer locks, a dr
The LiquoGuard 7 tube set consists of a tubing, stop cocks with luer locks, a drainage bag with a reflux valve, adapters to ensure correct insertion into the pump, and a pressure sensor housing with two pressure transducers, a cable for connection to the pump and a sticker to attach the sensor housing to the patient's skin. The tube set is only for use with the LiquoGuard 7.
The LiquoGuard 7 tube set consists of a tubing, stop cocks with luer locks, a dr
The LiquoGuard 7 tube set consists of a tubing, stop cocks with luer locks, a drainage bag with a reflux valve, adapters to ensure correct insertion into the pump, and a pressure sensor housing with two pressure transducers, a cable for connection to the pump and a sticker to attach the sensor housing to the patient's skin. The tube set is only for use with the LiquoGuard 7.
The LiquoGuard 7 tube set consists of a tubing, stop cocks with luer locks, a dr
The LiquoGuard 7 tube set consists of a tubing, stop cocks with luer locks, a drainage bag with a reflux valve, adapters to ensure correct insertion into the pump, and a pressure sensor housing with two pressure transducers, a cable for connection to the pump and a sticker to attach the sensor housing to the patient's skin. The tube set is only for use with the LiquoGuard 7.
The LiquoGuard 7 tube set consists of a tubing, stop cocks with luer locks, a dr
The LiquoGuard 7 tube set consists of a tubing, stop cocks with luer locks, a drainage bag with a reflux valve, adapters to ensure correct insertion into the pump, and a pressure sensor housing with two pressure transducers, a cable for connection to the pump and a sticker to attach the sensor housing to the patient's skin. The tube set is only for use with the LiquoGuard 7.
The LiquoGuard CSF system is indicated for the external drainage of cerebrospina
The LiquoGuard CSF system is indicated for the external drainage of cerebrospinal fluid (CSF). It connects to any drainage catheter (not part of the product) which is usually inserted by the doctor into the lateral or third ventricle of the brain or lumbarsubarachnoid space in selected patients to reduce intracranial pressure. The LiquoGuard CSF system controls CSF pressure using pressure sensors and a pump, thus taking the role of the conventional CSF dripping chamber and collection bag (predicate devices). The LiquoGuard CSF systemn also monitors intracranial pressure up to 75 mmHg and cerebrospinal fluid flow during CSF drainage, and provides many alarm functions not offered by the passive dripping chamber systems.
The LiquoGuard CSF system is indicated for the external drainage of cerebrospina
The LiquoGuard CSF system is indicated for the external drainage of cerebrospinal fluid (CSF). It connects to any drainage catheter (not part of the product) which is usually inserted by the doctor into the lateral or third ventricle of the brain or lumbar subarachnoid space in selected patients to reduce intracranial pressure. The LiquoGuard CSF system controls CSF pressure using pressure sensors and a pump, thus taking the role of the conventional CSF dripping chamber and collection bag (predicate devices). The LiquoGuard CSF system also monitors intracranial pressure up to 75 mmHg and cerebrospinal fluid flow during CSF drainage, and provides many alarm functions not offered by the passive dripping chamber systems.
The LiquoGuard 7 CSF Drainage System consists of a pump and a corresponding disp
The LiquoGuard 7 CSF Drainage System consists of a pump and a corresponding disposable drainage tube set, including two pressure sensors. The dynamic range of thissystem is from -75 mmHg to +100 mmHg. The drainage tube set is inserted into the pump, connected to the intrathecal drainage catheter (not part of the product) via a 3-way stopcock and the LiquoGuard 7 device via cable connector. The device continuously measures the pressure of CSF due to the fluid column inside the tube andoperates the peristaltic pump of LiquoGuard 7 whenever the current patient’s CSF pressure is higher than a preselected target pressure. Thus the LiquoGuard 7 combinesCSF drainage and intracranial pressure (ICP) monitoring like the predicate device, the LiquoGuard CSF System, with integrated alarm and documentation/data loggingfunctions, improving safety, simplifying the handling and enhancing patient’s mobility.
The LiquoGuard CSF system is indicated for the external drainage of cerebrospina
The LiquoGuard CSF system is indicated for the external drainage of cerebrospinal fluid (CSF). It connects to any drainage catheter (not part of the product) which is usually inserted by the doctor into the lateral or third ventricle of the brain or lumbar subarachnoid space in selected patients to reduce intracranial pressure. The LiquoGuard CSF system controls CSF pressure using pressure sensors and a pump, thus taking the role of the conventional CSF dripping chamber and collection bag (predicate devices). The LiquoGuard CSF system also monitors intracranial pressure up to 75 mmHg and cerebrospinal fluid flow during CSF drainage, and provides many alarm functions not offered by the passive dripping chamber systems.