Other products from "CARDINAL HEALTH 200, LLC"
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 50630140028920 4072 4072 Convertors Brand Bio-Shield Regular Sterilization Wrap FRG Wrap, sterilization CONVERTORS
2 50630140028913 4065 4065 Convertors Brand Bio-Shield Regular Sterilization Wrap FRG Wrap, sterilization CONVERTORS
3 50630140028906 4060 4060 Convertors Brand Bio-Shield Regular Sterilization Wrap FRG Wrap, sterilization CONVERTORS
4 50630140028890 4054 4054 Convertors Brand Bio-Shield Regular Sterilization Wrap FRG Wrap, sterilization CONVERTORS
5 50630140028883 4048 4048 Convertors Brand Bio-Shield Regular Sterilization Wrap FRG Wrap, sterilization CONVERTORS
6 50630140028876 4045 4045 Convertors Brand Bio-Shield Regular Sterilization Wrap FRG Wrap, sterilization CONVERTORS
7 50630140028869 4040 4040 Convertors Brand Bio-Shield Regular Sterilization Wrap FRG Wrap, sterilization CONVERTORS
8 50630140028845 4030 4030 Convertors Brand Bio-Shield Regular Sterilization Wrap FRG Wrap, sterilization CONVERTORS
9 50630140028838 4024 4024 Convertors Brand Bio-Shield Regular Sterilization Wrap FRG Wrap, sterilization CONVERTORS
10 50630140028821 4020 4020 Convertors Brand Bio-Shield Regular Sterilization Wrap FRG Wrap, sterilization CONVERTORS
11 50192253061497 TB9349NB TB9349NB Three Quarter Sheet BNS PUI Drape, surgical, exempt 2 CONVERTORS
12 50192253038123 8188NB 8188NC Overhead Table Cover W/Sterile Extension BNS PUI Drape, surgical, exempt 2 CONVERTORS
13 50192253025642 8476NA 8476NA U-Drape PUI Drape, surgical, exempt 2 CONVERTORS
14 50192253025628 8475N 8475N U-Drape Bulk 60X84 BNS PUI Drape, surgical, exempt 2 CONVERTORS
15 50192253025604 8474N 8474N U-Drape BNS PUI Drape, surgical, exempt 2 CONVERTORS
16 50192253021828 8750 8750 Prep Pad BNS PUI Drape, surgical, exempt CONVERTORS
17 50192253021811 2700N 2700N Infant Blanket BNS KME BEDDING, DISPOSABLE, MEDICAL CONVERTORS
18 50192253016404 599N 599N SURGICAL SLEEVE, BNS LYU ACCESSORY, SURGICAL APPAREL CONVERTORS
19 50192253002131 43335NS 43335NS Armchair Cover BNS PUI Drape, surgical, exempt CONVERTORS
20 50192253000342 48033MNS 48033MNS Pacemaker Drape BNS PUI Drape, surgical, exempt CONVERTORS
21 20885380174565 441201G 441201G Super Sponges NAB Gauze / sponge,nonresorbable for external use Dermacea
22 20885380174008 DP5004GT DP5004GT ChemoPlus Full Coverage Gown, Open Back, Extra Extra Large, Light Blue, Non-sterile FYA GOWN, SURGICAL ChemoPlus
23 20885380173995 DP5002GT DP5002GT ChemoPlus Full Coverage Gown, Open Back, Extra Large, Light Blue, Non-sterile FYA GOWN, SURGICAL ChemoPlus
24 20885380173988 DP5001GT DP5001GT ChemoPlus Full Coverage Gown, Open Back, Large, Light Blue, Non-sterile FYA GOWN, SURGICAL ChemoPlus
25 20885380173971 DP5003GT DP5003GT ChemoPlus Full Coverage Gown, Open Back, Regular/Medium, Light Blue, Non-sterile FYA GOWN, SURGICAL ChemoPlus
26 20885380172455 CT5505T CT5505T ChemoPlus Full Coverage Gown, Closed Back, XXL, Medium Blue, Non-sterile FYA GOWN, SURGICAL ChemoPlus
27 20885380172431 CT5504T CT5504T ChemoPlus Full Coverage Gown, Closed Back, XL, Medium Blue, Non-sterile FYA GOWN, SURGICAL ChemoPlus
28 20885380172417 CT5503T CT5503T ChemoPlus Full Coverage Gown, Closed Back, Large, Medium Blue, Non-sterile FYA GOWN, SURGICAL ChemoPlus
29 20885380172394 CT5502T CT5502T ChemoPlus Full Coverage Gown, Closed Back, Regular/Medium, Medium Blue, Non-sterile FYA GOWN, SURGICAL ChemoPlus
30 20885380172387 CT5500TS CT5500TS ChemoPlus Full Coverage Sleeve, Universal, Blue, Sterile LYU ACCESSORY, SURGICAL APPAREL ChemoPlus
31 20885380172370 CT5500T CT5500T ChemoPlus Full Coverage Sleeve, Universal, Blue, Non-sterile LYU ACCESSORY, SURGICAL APPAREL ChemoPlus
32 20885380169745 AT76835 AT76835 Level 3 Surgical Mask with anti-fog ahesive FXX Mask, surgical CONVERTORS
33 20885380125062 AT7505-P AT7505-P Surgical Mask FXX Mask, surgical CONVERTORS
34 20885380074209 AT744235 AT744235 Surgical Mask W/Lightweight Anti-Fog Strip FXX Mask, surgical CONVERTORS
35 20885380074193 AT744335 AT744335 Surgical Lightweight Anti-Fog Strip and Wraparound Eye Shield FXX Mask, surgical CONVERTORS
36 20885380073691 AT752007 AT752007 Surgical Mask W/Anti-Fog Film FXX Mask, surgical CONVERTORS
37 20885380072229 AT771145 AT771145A Inst-Gard Surgical Mask - Pediatric Print FXX Mask, surgical CONVERTORS
38 20885380072212 AT771141 AT771141 Inst-Gard Procedure Mask - Pediatric Print FXX Mask, surgical CONVERTORS
39 20885380072205 AT752005 AT752005 Surgical Mask W/Anti-Fog Film FXX Mask, surgical CONVERTORS
40 20885380072199 AT7511-WE AT7511-WE Procedure Mask W/Eye Shield FXX Mask, surgical CONVERTORS
41 20885380072182 AT7511 AT7511 Insta-Gard Procedure Mask, Blue FXX Mask, surgical CONVERTORS
42 20885380072151 AT74635-I AT74635-I Surgical Mask W/Anti-Fog Foam Strip and Wraparound Eye Shield FXX Mask, surgical CONVERTORS
43 20885380072144 AT74635 AT74635 Surgical Mask W/Anti Fog Foam Strip and Wraparound Eye Shield FXX Mask, surgical CONVERTORS
44 20885380072137 AT74631 AT74631 Procedure Mask W/Anti-Fog Foam Strip W/Wraparound Eye Shield FXX Mask, surgical CONVERTORS
45 20885380072120 AT74535 AT74535 Surgical Mask W/Anti-Fog Foam Strip FXX Mask, surgical CONVERTORS
46 20885380072113 AT74531 AT74531 Procedure Mask W/Anti-Fog Foam Strip FXX Mask, surgical CONVERTORS
47 20885380072090 AT51334 AT51334 Surgical Mask, Duck Bill Style, Blue FXX Mask, surgical CONVERTORS
48 20885380072076 AT73335 AT73335 Surgical Mask Dye-Free FXX Mask, surgical CONVERTORS
49 20885380072069 AT73035 AT73035 Surgical Mask Dye-Free FXX Mask, surgical CONVERTORS
50 20885380072052 AT72835 AT72835 Surgical Mask W/Anti-Fog Adhesive FXX Mask, surgical CONVERTORS
Other products with the same Product Code "FRZ"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 07613327487725 HM39SPU HM39SPU HoverMatt 39" W x 78" L N/A STRYKER SUSTAINABILITY SOLUTIONS, INC.
2 07613327487718 HM39SPU-B HM39SPU-B HoverMatt 39" W x 78" L N/A STRYKER SUSTAINABILITY SOLUTIONS, INC.
3 07613327487701 HM39SPU-LNK-B HM39SPU-LNK-B HoverMatt LINK 39" W x 78" L N/A STRYKER SUSTAINABILITY SOLUTIONS, INC.
4 07613327487695 HM50SPU HM50SPU HoverMatt 50" W x 78" L N/A STRYKER SUSTAINABILITY SOLUTIONS, INC.
5 07613327487688 HM50SPU-B HM50SPU-B HoverMatt 50" W x 78" L N/A STRYKER SUSTAINABILITY SOLUTIONS, INC.
6 07613327487671 HM50RPSPU HM50RPSPU HoverMatt 50" W x 78" L N/A STRYKER SUSTAINABILITY SOLUTIONS, INC.
7 07613327487664 HM39SPU-HLF-B HM39SPU-HLF-B HoverMatt Half-Matt 39" W x 45" L N/A STRYKER SUSTAINABILITY SOLUTIONS, INC.
8 07613327487657 HM34SPU-LNK-B HM34SPU-LNK-B HoverMatt LINK 34" W x 78" L N/A STRYKER SUSTAINABILITY SOLUTIONS, INC.
9 07613327487640 HM39SPU-HLF HM39SPU-HLF HoverMatt Half-Matt 39" W x 45 " L N/A STRYKER SUSTAINABILITY SOLUTIONS, INC.
10 07613327487633 HM39RPSPU HM39RPSPU HoverMatt 39" W x 78" L N/A STRYKER SUSTAINABILITY SOLUTIONS, INC.
11 07613327487626 HM34SPU HM34SPU HoverMatt 34" W x 78" L N/A STRYKER SUSTAINABILITY SOLUTIONS, INC.
12 07613327487619 HM39RPSPU-HLF HM39RPSPU-HLF HoverMatt Half-Matt 39" W x 45" L N/A STRYKER SUSTAINABILITY SOLUTIONS, INC.
13 07613327487602 HM34SPU-HLF HM34SPU-HLF HoverMatt Half-Matt 34" W x 45" L N/A STRYKER SUSTAINABILITY SOLUTIONS, INC.
14 07613327487596 HM34SPU-B HM34SPU-B HoverMatt 34" W x 78" L N/A STRYKER SUSTAINABILITY SOLUTIONS, INC.
15 07613327487589 HM34RPSPU-HLF HM34RPSPU-HLF HoverMatt Half-Matt 34" W x 45" L N/A STRYKER SUSTAINABILITY SOLUTIONS, INC.
16 07613327487572 HM34SPU-HLF-B HM34SPU-HLF-B HoverMatt Half-Matt 34" W x 45" L N/A STRYKER SUSTAINABILITY SOLUTIONS, INC.
17 07613327487565 HM34RPSPU HM34RPSPU HoverMatt 34" W x 78" L N/A STRYKER SUSTAINABILITY SOLUTIONS, INC.
18 06973852596035 HY603 Dimensions: 900*676*870, Product net weight: 45 Kg. Hi-Fortune KUNSHAN HI-FORTUNE HEALTH PRODUCTS CO.,LTD
19 04717677480788 N050SPS AIRPAL CAREMED SUPPLY INC.
20 04717677480771 N039SPS AIRPAL CAREMED SUPPLY INC.
21 04717677480764 N034SPS AIRPAL CAREMED SUPPLY INC.
22 04717677480757 N028SPSLH AIRPAL CAREMED SUPPLY INC.
23 04717677480375 028SPS AIRPAL CAREMED SUPPLY INC.
24 04717677480207 039SPS AIRPAL DISPOSABLE COVERS FOR THE TRANSFER PAD AIRPAL CAREMED SUPPLY INC.
25 04717677480191 034SPS AIRPAL DISPOSABLE COVERS FOR THE TRANSFER PAD AIRPAL CAREMED SUPPLY INC.
26 04717677480016 039DSN AIRPAL DISPOSABLE COVERS FOR THE TRANSFER PAD AIRPAL CAREMED SUPPLY INC.
27 04717677480009 034DSN AIRPAL DISPOSABLE COVERS FOR THE TRANSFER PAD AIRPAL CAREMED SUPPLY INC.
28 00855723007016 034SPS 034" Transfer Pad AIRPAL AIRPAL, INC.
29 00855723007009 039SPS 039" Transfer Pad AIRPAL AIRPAL, INC.
30 00854564008220 AMT220 AIR-MATT AIR SUPPLY 220V AIR-MATT AIR-MATT INCORPORATED
31 00854564008176 AMT120 AIR-MATT AIR SUPPLY AIR-MATT AIR-MATT INCORPORATED
32 00818566019288 3732 3732 PremierPro™ Air Transfer Mats are indicated for patients who are unable to trans PremierPro™ Air Transfer Mats are indicated for patients who are unable to transfer or turn by their own effort, both assisted and unassisted. Whose size and weight present possible risks to caregivers involved in the transfer of the patient. Use 2 or more caregivers during patient transfers. Do not use transfer mat until user manual is reviewed. Do not leave patient unattended on inflated transfer mat. Do not attempt to move patient on uninflated transfer mat. The maximum safe working load for all is l000lbs. AIR SUPPLY units may be compatible if they provide 3 psi pressure and 80 cfm capacity. The hose used may be a standard 1.75" diameter hose that may be secured with a snap fastener or hook & loop fastener. Always refer the air supply unit's operating instructions, observing all precautions and warnings. All safety guidelines within the air supply unit's operating instructions should be followed. May be used in situations that require transferring patients undergoing Magnetic Resonance Imaging. PremierPro Air Transfer Mats have been evaluated for use with MRI and have been determined to be safe for use. This conclusion is based on: Materials of construction for top and bottom fabrics include Nylon, PVC and Mesh. Air supply fasteners are not in the radio frequency field or the field of imaging and will not cause artifacts. Evaluation of these factors indicates PremierPro Air Transfer Mats are safe when used with patients undergoing MRI. Reusable models may be wiped down with disinfectant or laundered between patients. When laundering, a water and bleach mixture of 100:1 may be used. Wash the mat using hot water (s160° F/ 65° C) with a cold-water rinse. When drying, the dryer temperature should be s140° F/60° C. Drying time should be set at 60 mts. or less. The "Wrinkle Free" setting on the dryer should be set to "Off". The PremierPro Reusable Air Transfer Mat may also be air dried. The Air Transfer Mats may show signs of wear after repeated drying. PremierPro Air Transfer Mats SVS LLC
33 00818566019271 3731 3731 PremierPro™ Air Transfer Mats are indicated for patients who are unable to trans PremierPro™ Air Transfer Mats are indicated for patients who are unable to transfer or turn by their own effort, both assisted and unassisted. Whose size and weight present possible risks to caregivers involved in the transfer of the patient. Use 2 or more caregivers during patient transfers. Do not use transfer mat until user manual is reviewed. Do not leave patient unattended on inflated transfer mat. Do not attempt to move patient on uninflated transfer mat. The maximum safe working load for all is l000lbs. AIR SUPPLY units may be compatible if they provide 3 psi pressure and 80 cfm capacity. The hose used may be a standard 1.75" diameter hose that may be secured with a snap fastener or hook & loop fastener. Always refer the air supply unit's operating instructions, observing all precautions and warnings. All safety guidelines within the air supply unit's operating instructions should be followed. May be used in situations that require transferring patients undergoing Magnetic Resonance Imaging. PremierPro Air Transfer Mats have been evaluated for use with MRI and have been determined to be safe for use. This conclusion is based on: Materials of construction for top and bottom fabrics include Nylon, PVC and Mesh. Air supply fasteners are not in the radio frequency field or the field of imaging and will not cause artifacts. Evaluation of these factors indicates PremierPro Air Transfer Mats are safe when used with patients undergoing MRI. Reusable models may be wiped down with disinfectant or laundered between patients. When laundering, a water and bleach mixture of 100:1 may be used. Wash the mat using hot water (s160° F/ 65° C) with a cold-water rinse. When drying, the dryer temperature should be s140° F/60° C. Drying time should be set at 60 mts. or less. The "Wrinkle Free" setting on the dryer should be set to "Off". The PremierPro Reusable Air Transfer Mat may also be air dried. The Air Transfer Mats may show signs of wear after repeated drying. PremierPro Air Transfer Mats SVS LLC
34 00818566019264 3730 3730 PremierPro™ Air Transfer Mats are indicated for patients who are unable to trans PremierPro™ Air Transfer Mats are indicated for patients who are unable to transfer or turn by their own effort, both assisted and unassisted. Whose size and weight present possible risks to caregivers involved in the transfer of the patient. Use 2 or more caregivers during patient transfers. Do not use transfer mat until user manual is reviewed. Do not leave patient unattended on inflated transfer mat. Do not attempt to move patient on uninflated transfer mat. The maximum safe working load for all is l000lbs. AIR SUPPLY units may be compatible if they provide 3 psi pressure and 80 cfm capacity. The hose used may be a standard 1.75" diameter hose that may be secured with a snap fastener or hook & loop fastener. Always refer the air supply unit's operating instructions, observing all precautions and warnings. All safety guidelines within the air supply unit's operating instructions should be followed. May be used in situations that require transferring patients undergoing Magnetic Resonance Imaging. PremierPro Air Transfer Mats have been evaluated for use with MRI and have been determined to be safe for use. This conclusion is based on: Materials of construction for top and bottom fabrics include Nylon, PVC and Mesh. Air supply fasteners are not in the radio frequency field or the field of imaging and will not cause artifacts. Evaluation of these factors indicates PremierPro Air Transfer Mats are safe when used with patients undergoing MRI. Reusable models may be wiped down with disinfectant or laundered between patients. When laundering, a water and bleach mixture of 100:1 may be used. Wash the mat using hot water (s160° F/ 65° C) with a cold-water rinse. When drying, the dryer temperature should be s140° F/60° C. Drying time should be set at 60 minutes or less. The "Wrinkle Free" setting on the dryer should be set to "Off". The PremierPro Reusable Air Transfer Mat may also be air dried. The Air Transfer Mats may show signs of wear after repeated drying. PremierPro Air Transfer Mats SVS LLC
35 00818566019257 3723 3723 PremierPro™ Air Transfer Mats are indicated for patients who are unable to trans PremierPro™ Air Transfer Mats are indicated for patients who are unable to transfer or turn by their own effort, both assisted and unassisted. Whose size and weight present possible risks to caregivers involved in the transfer of the patient. Use 2 or more caregivers during patient transfers. Do not use transfer mat until user manual is reviewed. Do not leave patient unattended on inflated transfer mat. Do not attempt to move patient on uninflated transfer mat. The maximum safe working load for all is l000lbs. AIR SUPPLY units may be compatible if they provide 3 psi pressure and 80 cfm capacity. The hose used may be a standard 1.75" diameter hose that may be secured with a snap fastener or hook & loop fastener. Always refer the air supply unit's operating instructions, observing all precautions and warnings. All safety guidelines within the air supply unit's operating instructions should be followed. May be used in situations that require transferring patients undergoing Magnetic Resonance Imaging. PremierPro Air Transfer Mats have been evaluated for use with MRI and have been determined to be safe for use. This conclusion is based on: Materials of construction for top and bottom fabrics include Nylon, PVC and Mesh. Air supply fasteners are not in the radio frequency field or the field of imaging and will not cause artifacts. Evaluation of these factors indicates PremierPro Air Transfer Mats are safe when used with patients undergoing MRI. Reusable models may be wiped down with disinfectant or laundered between patients. When laundering, a water and bleach mixture of 100:1 may be used. Wash the mat using hot water (s160° F/ 65° C) with a cold-water rinse. When drying, the dryer temperature should be s140° F/60° C. Drying time should be set at 60 mts. or less. The "Wrinkle Free" setting on the dryer should be set to "Off". The PremierPro Reusable Air Transfer Mat may also be air dried. The Air Transfer Mats may show signs of wear after repeated drying. PremierPro Air Transfer Mats SVS LLC
36 00818566019240 3722 3722 ReusableINTENDED USE/ CONTRAINDICATIONSPrernierPro'" Air Transfer Mats are indic ReusableINTENDED USE/ CONTRAINDICATIONSPrernierPro'" Air Transfer Mats are indicated for patients• Who are unable to transfer or turn by their own effort. both assisted and unassisted• Whose size and weight present possible risks to caregivers involved in the transfer of the patientPRECAUTIONS & WARNINGS• Use two or more caregivers during patient transfers• Do not use transfer mat until user manual is reviewed.• Do not leave patient unattended on inflated transfer mat• Do not attempt to move patient on uninflated transfer mat.• The maximum safe working load for all PremierPro"' Air Transfer Mats is 1,000Ibs (450kg)AIR SUPPLYAir supply units may be compatible with PremierPro' " Air Transfer Mats if they provide 3 psi pressure and 80 cfm capacity. The hose used may be a standard 1.75" diameter hose that may be secured with a snap fastener or hook & loop fastener. Always refer the air supply unit’s operating Instructions, observing all precautions and warnings. All safety guidelines within the air supply unit' s operating Instructions should be followed.INSTRUCTIONS FOR USE1. Transfer surfaces should be close together and equal height or a slightly lower destination surface.2. Air inlet pockets are located at the foot end of pad. Locate and insert air supply hose.3. Avoid having obstructions in path of transfer including lines and hoses 4. Hold onto handles during inflation.5. Move patient in a diagonal direction. head or feet end first until patient reaches destination and is centered.6. Raise side rails, disconnect t air hose and undo safety straps.7. Use appropriate turning and rolling technique to remove transfer mat from underneath patient. PremierPro Air Transfer Mats SVS LLC
37 00818566019233 3721 3721 ReusableINTENDED USE/ CONTRAINDICATIONSPrernierPro'" Air Transfer Mats are indic ReusableINTENDED USE/ CONTRAINDICATIONSPrernierPro'" Air Transfer Mats are indicated for patients• Who are unable to transfer or turn by their own effort. both assisted and unassisted• Whose size and weight present possible risks to caregivers involved in the transfer of the patientPRECAUTIONS & WARNINGS• Use two or more caregivers during patient transfers• Do not use transfer mat until user manual is reviewed.• Do not leave patient unattended on inflated transfer mat• Do not attempt to move patient on uninflated transfer mat.• The maximum safe working load for all PremierPro"' Air Transfer Mats is 1,000Ibs (450kg)AIR SUPPLYAir supply units may be compatible with PremierPro' " Air Transfer Mats if they provide 3 psi pressure and 80 cfm capacity. The hose used may be a standard 1.75" diameter hose that may be secured with a snap fastener or hook & loop fastener. Always refer the air supply unit’s operating Instructions, observing all precautions and warnings. All safety guidelines within the air supply unit' s operating Instructions should be followed.INSTRUCTIONS FOR USE1. Transfer surfaces should be close together and equal height or a slightly lower destination surface.2. Air inlet pockets are located at the foot end of pad. Locate and insert air supply hose.3. Avoid having obstructions in path of transfer including lines and hoses 4. Hold onto handles during inflation.5. Move patient in a diagonal direction. head or feet end first until patient reaches destination and is centered.6. Raise side rails, disconnect t air hose and undo safety straps.7. Use appropriate turning and rolling technique to remove transfer mat from underneath patient. PremierPro Air Transfer Mats SVS LLC
38 00818566019226 3720 3720 ReusableINTENDED USE/ CONTRAINDICATIONSPrernierPro'" Air Transfer Mats are indic ReusableINTENDED USE/ CONTRAINDICATIONSPrernierPro'" Air Transfer Mats are indicated for patients• Who are unable to transfer or turn by their own effort. both assisted and unassisted• Whose size and weight present possible risks to caregivers involved in the transfer of the patientPRECAUTIONS & WARNINGS• Use two or more caregivers during patient transfers• Do not use transfer mat until user manual is reviewed.• Do not leave patient unattended on inflated transfer mat• Do not attempt to move patient on uninflated transfer mat.• The maximum safe working load for all PremierPro"' Air Transfer Mats is 1,000Ibs (450kg)AIR SUPPLYAir supply units may be compatible with PremierPro' " Air Transfer Mats if they provide 3 psi pressure and 80 cfm capacity. The hose used may be a standard 1.75" diameter hose that may be secured with a snap fastener or hook & loop fastener. Always refer the air supply unit’s operating Instructions, observing all precautions and warnings. All safety guidelines within the air supply unit' s operating Instructions should be followed.INSTRUCTIONS FOR USE1. Transfer surfaces should be close together and equal height or a slightly lower destination surface.2. Air inlet pockets are located at the foot end of pad. Locate and insert air supply hose.3. Avoid having obstructions in path of transfer including lines and hoses 4. Hold onto handles during inflation.5. Move patient in a diagonal direction. head or feet end first until patient reaches destination and is centered.6. Raise side rails, disconnect t air hose and undo safety straps.7. Use appropriate turning and rolling technique to remove transfer mat from underneath patient. PremierPro Air Transfer Mats SVS LLC
39 00818566019219 3711 3711 INTENDED USE/ CONTRAINDICATIONSPremierPro™ Air Transfer Mats are indicated for p INTENDED USE/ CONTRAINDICATIONSPremierPro™ Air Transfer Mats are indicated for patients:Who are unable to transfer or turn by their own effort, both assisted and unassisted.Whose size and weight present possible risks to caregivers involved in the transfer of the patient.PRECAUTIONS & WARNINGSUse two or more caregivers during patient transfers.Do not use transfer mat until user manual is reviewed.Do not leave patient unattended on inflated transfer mat.Do not attempt to move patient on uninflated transfer mat.The maximum safe working load for all PremierPro™ Air Transfer Mats is l,000lbs (450kg).AIR SUPPLYAir supply units may be compatible with Premier™ Air Transfer Mats if they provide 3 psi pressure and 80 cfm capacity. The hose used may be a standard 1.75" diameter hose that may be secured with a snap fastener or hook & loop fastener. Always refer the air supply unit's operating instructions, observing all precautions and warnings. All safety guidelines within the air supply unit's operating instructions should be followed.MRI SAFETYPremierPro™ Air Transfer Mats may be used in situations that require transferring patients undergoing Magnetic Resonance Imaging (MRI). PremierPro™ Air Transfer Mats have been evaluated for use with MRI and have been determined to be safe for use. This conclusion is based on the following factors:Materials of construction for top and bottom fabrics include Nylon, PVC and Mesh.Safety strap buckles are constructed from Polypropylene.Air supply fasteners are manufactured from non-ferrous metal.Air supply fasteners are not in the radio frequency field or the field of imaging and will not cause artifacts.Evaluation of these factors indicates PremierPro™ Air Transfer Mats are safe when used with patients undergoing MRI.CLEANINGThe PremierPro™ Disposable Air Transfer Mat is not intended to be laundered and reused. Check Local, State and Federal Guidelines before disposing of this product. PremierPro Air Transfer Mat SVS LLC
40 00818566019202 3710 3710 INTENDED USE/ CONTRAINDICATIONSPremierPro™ Air Transfer Mats are indicated for p INTENDED USE/ CONTRAINDICATIONSPremierPro™ Air Transfer Mats are indicated for patients:Who are unable to transfer or turn by their own effort, both assisted and unassisted.Whose size and weight present possible risks to caregivers involved in the transfer of the patient.PRECAUTIONS & WARNINGSUse two or more caregivers during patient transfers.Do not use transfer mat until user manual is reviewed.Do not leave patient unattended on inflated transfer mat.Do not attempt to move patient on uninflated transfer mat.The maximum safe working load for all PremierPro™ Air Transfer Mats is l,000lbs (450kg).AIR SUPPLYAir supply units may be compatible with Premier™ Air Transfer Mats if they provide 3 psi pressure and 80 cfm capacity. The hose used may be a standard 1.75" diameter hose that may be secured with a snap fastener or hook & loop fastener. Always refer the air supply unit's operating instructions, observing all precautions and warnings. All safety guidelines within the air supply unit's operating instructions should be followed.MRI SAFETYPremierPro™ Air Transfer Mats may be used in situations that require transferring patients undergoing Magnetic Resonance Imaging (MRI). PremierPro™ Air Transfer Mats have been evaluated for use with MRI and have been determined to be safe for use. This conclusion is based on the following factors:Materials of construction for top and bottom fabrics include Nylon, PVC and Mesh.Safety strap buckles are constructed from Polypropylene.Air supply fasteners are manufactured from non-ferrous metal.Air supply fasteners are not in the radio frequency field or the field of imaging and will not cause artifacts.Evaluation of these factors indicates PremierPro™ Air Transfer Mats are safe when used with patients undergoing MRI.CLEANINGThe PremierPro™ Disposable Air Transfer Mat is not intended to be laundered and reused. Check Local, State and Federal Guidelines before disposing of this product. PremierPro Air Transfer Mat SVS LLC
41 00818566019196 3703 3703 AIR SUPPLYAir supply units may be compatible with PremierPro™ Air Transfer Ma AIR SUPPLYAir supply units may be compatible with PremierPro™ Air Transfer Mats if they provide 3 psi pressure and 80 cfm capacity. The hose used may be a standard 1.75" diameter hose that may be secured with a snap fastener or hook & loop fastener. Always refer the air supply unit's operating instructions, observing all precautions and warnings. All safety guidelines within the air supply unit's operating instructions should be followed.MRI SAFETYPremierPro™ Air Transfer Mats may be used in situations that require transferring patients undergoing Magnetic Resonance Imaging (MRI). PremierPro™ Air Transfer Mats have been evaluated for use with MRI and have been determined to be safe for use. This conclusion is based on the following factors:Materials of construction for top and bottom fabrics include Nylon, PVC and Mesh.Safety strap buckles are constructed from Polypropylene.Air supply fasteners are manufactured from non-ferrous metal.Air supply fasteners are not in the radio frequency field or the field of imaging and will not cause artifacts.Evaluation of these factors indicates PremierPro™ Air Transfer Mats are safe when used with patients undergoing MRI.CLEANINGDisposable ModelsThe PremierPro™ Disposable Air Transfer Mat is not intended to be laundered and reused. Check Local, State and Federal Guidelines before disposing of this product. PremierPro Air Transfer Mats SVS LLC
42 00818566019189 3702 AIR SUPPLYAir supply units may be compatible with PremierPro™ Air Transfer Ma AIR SUPPLYAir supply units may be compatible with PremierPro™ Air Transfer Mats if they provide 3 psi pressure and 80 cfm capacity. The hose used may be a standard 1.75" diameter hose that may be secured with a snap fastener or hook & loop fastener. Always refer the air supply unit's operating instructions, observing all precautions and warnings. All safety guidelines within the air supply unit's operating instructions should be followed.MRI SAFETYPremierPro™ Air Transfer Mats may be used in situations that require transferring patients undergoing Magnetic Resonance Imaging (MRI). PremierPro™ Air Transfer Mats have been evaluated for use with MRI and have been determined to be safe for use. This conclusion is based on the following factors:Materials of construction for top and bottom fabrics include Nylon, PVC and Mesh.Safety strap buckles are constructed from Polypropylene.Air supply fasteners are manufactured from non-ferrous metal.Air supply fasteners are not in the radio frequency field or the field of imaging and will not cause artifacts.Evaluation of these factors indicates PremierPro™ Air Transfer Mats are safe when used with patients undergoing MRI.CLEANINGDisposable ModelsThe PremierPro™ Disposable Air Transfer Mat is not intended to be laundered and reused. Check Local, State and Federal Guidelines before disposing of this product. PremierPro Air Trasnsfer SVS LLC
43 00818566019172 3701 3701 INTENDED USE/ CONTRAINDICATIONSPrernierPro'" Air Transfer Mats are indicated for INTENDED USE/ CONTRAINDICATIONSPrernierPro'" Air Transfer Mats are indicated for patients• Who are unable to transfer or turn by their own effort. both assisted and unassisted• Whose size and weight present possible risks to caregivers involved in the transfer of the patientPRECAUTIONS & WARNINGS• Use two or more caregivers during patient transfers• Do not use transfer mat until user manual is reviewed.• Do not leave patient unattended on inflated transfer mat• Do not attempt to move patient on uninflated transfer mat.• The maximum safe working load for all PremierPro"' Air Transfer Mats is 1,000Ibs (450kg)AIR SUPPLYAir supply units may be compatible with PremierPro' " Air Transfer Mats if they provide 3 psi pressure and 80 cfm capacity. The hose used may be a standard 1.75" diameter hose that may be secured with a snap fastener or hook & loop fastener. Always refer the air supply unit’s operating Instructions, observing all precautions and warnings. All safety guidelines within the air supply unit' s operating Instructions should be followed.INSTRUCTIONS FOR USE1. Transfer surfaces should be close together and equal height or a slightly lower destination surface.2. Air inlet pockets are located at the foot end of pad. Locate and insert air supply hose.3. Avoid having obstructions in path of transfer including lines and hoses 4. Hold onto handles during inflation.5. Move patient in a diagonal direction. head or feet end first until patient reaches destination and is centered.6. Raise side rails, disconnect t air hose and undo safety straps.7. Use appropriate turning and rolling technique to remove transfer mat from underneath patient. PremierPro Air Transfer Mats SVS LLC
44 00818566019165 3700 3700 INTENDED USE/ CONTRAINDICATIONSPremierPro™ Air Transfer Mats are indicated for p INTENDED USE/ CONTRAINDICATIONSPremierPro™ Air Transfer Mats are indicated for patients:Who are unable to transfer or turn by their own effort, both assisted and unassisted.Whose size and weight present possible risks to caregivers involved in the transfer of the patient.PRECAUTIONS & WARNINGSUse two or more caregivers during patient transfers.Do not use transfer mat until user manual is reviewed.Do not leave patient unattended on inflated transfer mat.Do not attempt to move patient on uninflated transfer mat.The maximum safe working load for all PremierPro™ Air Transfer Mats is l,000lbs (450kg).AIR SUPPLYAir supply units may be compatible with Premier™ Air Transfer Mats if they provide 3 psi pressure and 80 cfm capacity. The hose used may be a standard 1.75" diameter hose that may be secured with a snap fastener or hook & loop fastener. Always refer the air supply unit's operating instructions, observing all precautions and warnings. All safety guidelines within the air supply unit's operating instructions should be followed.MRI SAFETYPremierPro™ Air Transfer Mats may be used in situations that require transferring patients undergoing Magnetic Resonance Imaging (MRI). PremierPro™ Air Transfer Mats have been evaluated for use with MRI and have been determined to be safe for use. This conclusion is based on the following factors:Materials of construction for top and bottom fabrics include Nylon, PVC and Mesh.Safety strap buckles are constructed from Polypropylene.Air supply fasteners are manufactured from non-ferrous metal.Air supply fasteners are not in the radio frequency field or the field of imaging and will not cause artifacts.Evaluation of these factors indicates PremierPro™ Air Transfer Mats are safe when used with patients undergoing MRI.CLEANINGThe PremierPro™ Disposable Air Transfer Mat is not intended to be laundered and reused. Check Local, State and Federal Guidelines before disposing of this product. PremierPro Air Transfer Mats SVS LLC
45 00816299011715 HMHC-39 HMHC-39 HoverMatt SPU Plus HoverCover HoverMatt SPU Plus HoverCover HOVERTECH INTERNATIONAL
46 00816299011692 HMHC-34 HMHC-34 34" HoverMatt Plus HoverCover Kit HoverMatt SPU Plus HoverCover HOVERTECH INTERNATIONAL
47 00816299011265 SW400AIR SW400AIR 1100W SizeWise Air Supply SizeWise Air Supply HOVERTECH INTERNATIONAL
48 00816299011258 HTAIR2356 HTAIR2356 230V, 50/60Hz HTAIR HoverTech Air Supply HoverTech Air Supply HOVERTECH INTERNATIONAL
49 00816299011241 HTAIR2300 HTAIR2300 230V, 50Hz HTAIR HoverTech Air Supply HoverTech Air Supply HOVERTECH INTERNATIONAL
50 00816299011234 HTAIR1200 HTAIR1200 120V, 60Hz HTAIR HoverTech Air Supply HoverTech Air Supply HOVERTECH INTERNATIONAL