FGT System Cutting Guide, LargeInstrument utilized to resect the base of the pro
FGT System Cutting Guide, LargeInstrument utilized to resect the base of the proximalphalanx and distal portion of the metatarsal head.
FGT System Cutting Guide, SmallInstrument utilized to resect the base of the pro
FGT System Cutting Guide, SmallInstrument utilized to resect the base of the proximalphalanx and distal portion of the metatarsal head.
Integra® MemoFix® Staple SystemThe MemoFix Staple Instrument Tray contains instr
Integra® MemoFix® Staple SystemThe MemoFix Staple Instrument Tray contains instruments used to aid in the implantation of the MemoFix Staples.
Ascension® PIPThe PIP disposable pack for Linvatec/Hall includes a blade, a side
Ascension® PIPThe PIP disposable pack for Linvatec/Hall includes a blade, a side burr, a planer burr, and a guide pin.
Integra® First Choice® DRUJ SystemDRUJ Osteotomy GuideThe DRUJ (distal radioulna
Integra® First Choice® DRUJ SystemDRUJ Osteotomy GuideThe DRUJ (distal radioulnar joint) Osteotomy Guide attaches onto reamers and is used to determine a standard, medium, or long resection for partial resurfacing implants.
Integra® First Choice® DRUJ SystemMUH Osteotomy GuideThe Modular Ulnar Head Oste
Integra® First Choice® DRUJ SystemMUH Osteotomy GuideThe Modular Ulnar Head Osteotomy Guide attaches onto reamers and is used to determine a standard, medium, or long resection.
Integra® First Choice® DRUJ SystemMUH Resection GuideThe Modular Ulnar Head Rese
Integra® First Choice® DRUJ SystemMUH Resection GuideThe Modular Ulnar Head Resection Guide is placed against the distal ulna to determine a standard, medium, or long resection of the ulnar head.
Movement® Great Toe SystemThe sizer alignment guide is used with the Movement Gr
Movement® Great Toe SystemThe sizer alignment guide is used with the Movement Great Toe system.
Ascension® PIPThe PIP disposable pack for Stryker includes a blade, a side burr,
Ascension® PIPThe PIP disposable pack for Stryker includes a blade, a side burr, a planer burr, and a guide pin.
The drilling guide is used to guide the drills while preparing the holes for the
The drilling guide is used to guide the drills while preparing the holes for the staples. After having decided which interaxis between the two legs of the staple, the guide is ajusted and the holes are drilled.The joint should be in the middle between the two sleeves of the guide.
The SURFIX® cutting guide is used to define he angle of the bone cutting and to
The SURFIX® cutting guide is used to define he angle of the bone cutting and to guide the resection of a bone wedge when a closing wedge osteotomy is implemented.
This K-Wire of diameter 2.5 mm and of length 250 mm is used to guide the instrum
This K-Wire of diameter 2.5 mm and of length 250 mm is used to guide the instrumentation and the screws.
The drilling guide is used to guide the drills while preparing the holes for the
The drilling guide is used to guide the drills while preparing the holes for the fixation screws.
The short protection sleeve is used to guide the drills while preparing the hole
The short protection sleeve is used to guide the drills while preparing the holes for the fixation screws.
The medium protection sleeve is used to guide the drills while preparing the hol
The medium protection sleeve is used to guide the drills while preparing the holes for the fixation screws.
The drilling guide is used to guide the drills while preparing the holes for the
The drilling guide is used to guide the drills while preparing the holes for the fixation screws.
The long drilling guide is used to guide the drills while preparing the holes fo
The long drilling guide is used to guide the drills while preparing the holes for the fixation screws.
The short drilling guide is used to guide the drills while preparing the holes f
The short drilling guide is used to guide the drills while preparing the holes for the fixation screws.
The medium drilling guide is used to guide the drills while preparing the holes
The medium drilling guide is used to guide the drills while preparing the holes for the fixation screws.
The sterile guide pin of diameter 3.2 mm and of length 600 mm is used to guide d
The sterile guide pin of diameter 3.2 mm and of length 600 mm is used to guide drills, reamers and nail into the intramedullary canal.
The non sterile guide pin of diameter 3.2 mm and of length 600 mm is used to gui
The non sterile guide pin of diameter 3.2 mm and of length 600 mm is used to guide drills, reamers and nail into the intramedullary canal.
The non sterile guide pin of diameter 3.2 mm and of length 400 mm is used to gui
The non sterile guide pin of diameter 3.2 mm and of length 400 mm is used to guide drills, reamers and nail into the intramedullary canal.
The plantar external protecting sleeve is used to protect the surrounding soft t
The plantar external protecting sleeve is used to protect the surrounding soft tissues during drilling. This model has an inner sleeve diameter of 14 mm.