Other products from "VORTRAN MEDICAL TECHNOLOGY 1, INC"
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 10637320050025 PTE-5002 PTE-5002 The VAR® device is a unique single-patient-use, disposable resuscitator. It prov The VAR® device is a unique single-patient-use, disposable resuscitator. It provides hands-free ventilator support via a mask or endotracheal tube using a continuous gas flow source. The VAR® device can be operated on a compressor, oxygen or compressed air. Since it does not require the use of electricity or batteries, it is an ideal backup ventilator for the management of mass casualty incidents, natural disasters, disease outbreaks, major power outages and other extraordinary emergencies. An additional advantage of the VAR® device is that it does not interfere with MRI and CT scans. BTL Ventilator, Emergency, Powered (Resuscitator) 2 VAR (VORTRAN Automatic Resuscitator) with Extension
2 10637320024507 2450 2450 The VORTRAN® Cuff Inflator (VCI) is a hand-held measuring device intended to mea The VORTRAN® Cuff Inflator (VCI) is a hand-held measuring device intended to measure and manually regulate intra-cuff pressure of Endotracheal, Tracheostomy, and LMA tubes. BSK Cuff, Tracheal Tube, Inflatable 2 VCI (VORTRAN Cuff Inflator)
3 10637320040309 PNB-4030 PNB-4030 The PercussiveNEB® device is a single-patient use percussor, which makes it poss The PercussiveNEB® device is a single-patient use percussor, which makes it possible for individuals to receive multiple high frequency treatments while using the same device. Other percussive devices need to be cleaned between patients and also require waiting for the equipment to become available. It is easy to use with quick set-up time and patient initiates and controls the percussion levels. It can be used by patients in the hospital or in the home NHJ Device, Positive Pressure Breathing, Intermittent 2 VORTRAN PercussiveNEB
4 10637320040200 IP-4020 IP-4020 The VORTRAN®-IPPB allows for single-patient use of an airway clearance device. The VORTRAN®-IPPB allows for single-patient use of an airway clearance device. It provides high aerosol output with a large nebulizer reservoir. It is easily set-up and more cost effective than a conventional IPPB machine. It is excellent for patients with fluid retention in the lungs. NHJ Device, Positive Pressure Breathing, Intermittent 2 VORTRAN-IPPB
5 10637320039600 3960 3960 The VORTRAN® APM-Plus is a battery (2 x AA) operated, microprocessor controlled, The VORTRAN® APM-Plus is a battery (2 x AA) operated, microprocessor controlled, portable, self-contained device designed for monitoring a positive airway-pressure device such as a resuscitator or bubble CPAP. The VORTRAN® APM-Plus is housed in a plastic enclosure and includes a number of associated accessories. It connects to the positive-pressure device under monitor via pneumatic pressure tubing and receives the pressure signals using its solid-state pressure transducer. The pressure signals are used to calculate the related characteristics which are displayed on the LCD screen. The values are used to trigger alarms that alert the user of any abnormal pressure conditions. The software algorithm constantly monitors the data and if/when the pressure characteristics are outside of the user-set limits, an alarm will be activated. The alarms are both visual and audible. For ease of use, the VORTRAN® APM-Pus software provides two modes of operations: Resuscitator Mode and PAP Mode. CAP Monitor, Airway Pressure (Includes Gauge And/Or Alarm) 2 VORTRAN® APM-Plus
6 10637320039006 APM-3900 APM-3900 The APM (Airway Pressure Monitor) is a battery operated, portable, self-containe The APM (Airway Pressure Monitor) is a battery operated, portable, self-contained device that is connected to the patient via the connection kit to monitor the cycling conditions of resuscitators. It give clinicians patient ventilation parameters (PIP, PEEP, Respiration Rate, I:E ratio) and provides visual alarm display with flashing LED and loud audible alarm. It allows clinicians to have a true value of patient status during ventilation similar to a full-featured ventilator. It is easy to set up and use. Offers different connection kit options. CAP Monitor, Airway Pressure (Includes Gauge And/Or Alarm) 2 VORTRAN Airway Pressure Monitor
7 10637320062004 6200 6200 The VORTRAN GO2VENT with PEEP Valve is to be used by properly trained personnel The VORTRAN GO2VENT with PEEP Valve is to be used by properly trained personnel to deliver emergency, short-term, constant flow, pressure-cycled ventilatory support on patients weighing 10 kg and above. BTL Ventilator, Emergency, Powered (Resuscitator) 2 VORTRAN GO2VENT with PEEP Valve
8 10637320081005 8100 8100 The VORTRAN Medical Air Compressor is a compressor designed for continuous, high The VORTRAN Medical Air Compressor is a compressor designed for continuous, high pressure performance, easy and practical for home and hospital uses. It is capable of servicing nebulizer and humidifiers to product particle aerosol mist. BTI Compressor, Air, Portable 2 VORTRAN Medical Air Compressor
9 10637320060314 6031 6031 The VORTRAN Pressure Manometer provides pressure readings from a breathing circu The VORTRAN Pressure Manometer provides pressure readings from a breathing circuit in the range of 0 to 60 cm-H2O. The pressure readouts are approximate with an accuracy of ±2 cm-H2O for a low pressure range from 0 to 20 cm-H2O; ±3 cm-H2O for a pressure range of 20 to 40 cm-H2O; and ±5 cm-H2O for pressures above 40 cm-H2O. The manometer design requirements include: the pressure range of 0 to 60 cm-H2O, connection to a breathing circuit via a 22 mm male-female adaptor, and having a life expectancy as a single patient multiple use device. It accommodates connections through the option of a 22 mm tee or 15 mm port. The manometer includes a translucent enclosure that allows the pressure indicator needle to be seen from all sides. CAP Monitor, Airway Pressure (Includes Gauge And/Or Alarm) 2 VORTRAN MANOMETER
10 10637320060307 6030 6030 The VORTRAN Pressure Manometer provides pressure readings from a breathing circu The VORTRAN Pressure Manometer provides pressure readings from a breathing circuit in the range of 0 to 60 cm-H2O. The pressure readouts are approximate with an accuracy of ±2 cm-H2O for a low pressure range from 0 to 20 cm-H2O; ±3 cm-H2O for a pressure range of 20 to 40 cm-H2O; and ±5 cm-H2O for pressures above 40 cm-H2O. The manometer design requirements include: the pressure range of 0 to 60 cm-H2O, connection to a breathing circuit via a 22 mm male-female adaptor, and having a life expectancy as a single patient multiple use device. It accommodates connections through the option of a 22 mm tee or 15 mm port. The manometer includes a translucent enclosure that allows the pressure indicator needle to be seen from all sides. CAP Monitor, Airway Pressure (Includes Gauge And/Or Alarm) 2 VORTRAN MANOMETER
11 10637320000112 6600 6600 The GO2VENT provides constant fl ow, pressure cycled ventilatory support in eith The GO2VENT provides constant fl ow, pressure cycled ventilatory support in either pressure controlor pressure support modes on patients weighing 10kg and above. The device includes the pulmonarymodulator (an exhalation valve that opens at PIP and closes at PEEP) and a patient connector teeto supply gas fl ow, entrain additional air, and provides a redundant pop-off valve for safety. Theworking mechanism of the GO2VENT consists of a moving diaphragm which adds or subtractsspring force when it is moved from a horizontal to a vertical position, the addition or subtraction ofspring force will aff ect the PIP setting by 1~3 cm-H2O. The GO2VENT will function in any position aslong as the fi nal adjustments are made in a secured position (strapped or taped to the patient). BTL Ventilator, Emergency, Powered (Resuscitator) VORTRAN GO2VENT
12 20637320050503 PCK-5050 PCK-5050 Kit Contains: 3 each GO2VENT Model 6123; 1 each Oxygen Regulator; 1 each Traini Kit Contains: 3 each GO2VENT Model 6123; 1 each Oxygen Regulator; 1 each Training CD; 1 each Test Lung VAR Surgical Center Kit
13 20637320035005 VM-3500 VM-3500 The VAR-Monitor is mounted onto the exhalation side of the VAR and has no direct The VAR-Monitor is mounted onto the exhalation side of the VAR and has no direct patient contact during its operation. If the VAR stops cycling, the VAR-Monitor™ detects the non-cycling condition and generates both an audible sound and a visible blinking (red color LED) light alerting the clinician who is attending the patient. BTL Ventilator, Emergency, Powered (Resuscitator) 2 VAR-Monitor
14 10637320060017 6001 6001 The GO2VENT provides constant fl ow, pressure cycled ventilatory support in eith The GO2VENT provides constant fl ow, pressure cycled ventilatory support in either pressure control or pressure support modes on patients weighing 10kg and above. The device includes the pulmonary modulator (an exhalation valve that opens at PIP and closes at PEEP) and a patient connector tee to supply gas fl ow, entrain additional air, and provides a redundant pop-off valve for safety. The working mechanism of the GO2VENT consists of a moving diaphragm which adds or subtracts spring force when it is moved from a horizontal to a vertical position, the addition or subtraction of spring force will aff ect the PIP setting by 1~3 cm-H2O. The GO2VENT will function in any position as long as the fi nal adjustments are made in a secured position (strapped or taped to the patient). BTL Ventilator, Emergency, Powered (Resuscitator) 2 VORTRAN GO2VENT
15 10637320050117 PCM-5011 PCM-5011 The VAR® device is a unique single-patient-use, disposable resuscitator. It prov The VAR® device is a unique single-patient-use, disposable resuscitator. It provides hands-free ventilator support via a mask or endotracheal tube using a continuous gas flow source. The VAR® device can be operated on a compressor, oxygen or compressed air. Since it does not require the use of electricity or batteries, it is an ideal backup ventilator for the management of mass casualty incidents, natural disasters, disease outbreaks, major power outages and other extraordinary emergencies. An additional advantage of the VAR® device is that it does not interfere with MRI and CT scans. BTL Ventilator, Emergency, Powered (Resuscitator) 2 VAR (VORTRAN Automatic Resuscitator) with Manometer
16 10637320050100 PC-5010 PC-5010 The VAR® device is a unique single-patient-use, disposable resuscitator. It prov The VAR® device is a unique single-patient-use, disposable resuscitator. It provides hands-free ventilator support via a mask or endotracheal tube using a continuous gas flow source. The VAR® device can be operated on a compressor, oxygen or compressed air. Since it does not require the use of electricity or batteries, it is an ideal backup ventilator for the management of mass casualty incidents, natural disasters, disease outbreaks, major power outages and other extraordinary emergencies. An additional advantage of the VAR® device is that it does not interfere with MRI and CT scans. BTL Ventilator, Emergency, Powered (Resuscitator) 2 VAR (VORTRAN Automatic Resuscitator)
17 10637320050018 PTM-5001 PTM-5001 The VAR® device is a unique single-patient-use, disposable resuscitator. It prov The VAR® device is a unique single-patient-use, disposable resuscitator. It provides hands-free ventilator support via a mask or endotracheal tube using a continuous gas flow source. The VAR® device can be operated on a compressor, oxygen or compressed air. Since it does not require the use of electricity or batteries, it is an ideal backup ventilator for the management of mass casualty incidents, natural disasters, disease outbreaks, major power outages and other extraordinary emergencies. An additional advantage of the VAR® device is that it does not interfere with MRI and CT scans. BTL Ventilator, Emergency, Powered (Resuscitator) 2 VAR (VORTRAN Automatic Resuscitator) with Manometer
18 10637320050001 PT-5000 PT-5000 The VAR® device is a unique single-patient-use, disposable resuscitator. It prov The VAR® device is a unique single-patient-use, disposable resuscitator. It provides hands-free ventilator support via a mask or endotracheal tube using a continuous gas flow source. The VAR® device can be operated on a compressor, oxygen or compressed air. Since it does not require the use of electricity or batteries, it is an ideal backup ventilator for the management of mass casualty incidents, natural disasters, disease outbreaks, major power outages and other extraordinary emergencies. An additional advantage of the VAR® device is that it does not interfere with MRI and CT scans. BTL Ventilator, Emergency, Powered (Resuscitator) VAR (VORTRAN Automatic Resuscitator)
19 10637320000167 6123-16 6123-16 The GO2VENT provides constant flow, pressure cycled ventilatory support in either The GO2VENT provides constant flow, pressure cycled ventilatory support in either pressure control or pressure support modes on patients weighing 10kg and above. The device includes the pulmonary modulator (an exhalation valve that opens at PIP and closes at PEEP) and a patient connector tee to supply gas flow, entrain additional air, and provides a redundant pop-off valve for safety. The working mechanism of the GO2VENT consists of a moving diaphragm which adds or subtracts spring force when it is moved from a horizontal to a vertical position, the addition or subtraction of spring force will affect the PIP setting by 1~3 cm-H2O. The GO2VENT will function in any position as long as the final adjustments are made in a secured position (strapped or taped to the patient). BTL Ventilator, Emergency, Powered (Resuscitator) 2 VORTRAN GO2VENT
20 10637320000105 6123 6123 The GO2VENT provides constant flow, pressure cycled ventilatory support in eithe The GO2VENT provides constant flow, pressure cycled ventilatory support in either pressure control or pressure support modes on patients weighing 10kg and above. The device includes the pulmonary modulator (an exhalation valve that opens at PIP and closes at PEEP) and a patient connector tee to supply gas flow, entrain additional air, and provides a redundant pop-off valve for safety. The working mechanism of the GO2VENT consists of a moving diaphragm which adds or subtracts spring force when it is moved from a horizontal to a vertical position, the addition or subtraction of spring force will affect the PIP setting by 1~3 cm-H2O. The GO2VENT will function in any position as long as the final adjustments are made in a secured position (strapped or taped to the patient). BTL Ventilator, Emergency, Powered (Resuscitator) 2 VORTRAN GO2VENT
21 20637320040702 ES-4070 ES-4070 Kit Includes: 6 each VAR Model PCM-5011, 4 each VAR Monitors; 4 each Oxygen Flo Kit Includes: 6 each VAR Model PCM-5011, 4 each VAR Monitors; 4 each Oxygen Flowmeters; 1 each Multi-outlet manifold; 1 each 20' Heavy Duty Oxygen Hose; 1 each Watertight Carrying Case; 10 each HME Filters E-Surge Kit
22 10637320080404 8040 8040 The PercussiveNEB 2.0 with Top Nebulizer Port is an intrapulmonary percussive tr The PercussiveNEB 2.0 with Top Nebulizer Port is an intrapulmonary percussive treatment device that can incorporate a nebulizer which delivers aerosolized medication and is designed to oscillate during exhalation and inhalation to help remove endobronchial secretions. NHJ Device, Positive Pressure Breathing, Intermittent 2 VORTRAN PercussiveNEB 2.0 w/ Top Nebulizer Port
23 10637320080305 8030 8030 The PercussiveNEB 2.0 is an intrapulmonary percussive treatment device that inco The PercussiveNEB 2.0 is an intrapulmonary percussive treatment device that incorporates a nebulizer which delivers aerosolized medication and is designed to oscillate during exhalation and inhalation to help remove endobronchial secretions. NHJ Device, Positive Pressure Breathing, Intermittent 2 VORTRAN PercussiveNEB 2.0
24 10637320040224 IPM-4022 IPM-4022 The VORTRAN®-IPPB allows for single-patient use of an airway clearance device. I The VORTRAN®-IPPB allows for single-patient use of an airway clearance device. It provides high aerosol output with a large nebulizer reservoir. It is easily set-up and more cost effective than a conventional IPPB machine. It is excellent for patients with fluid retention in the lungs. NHJ Device, Positive Pressure Breathing, Intermittent 2 VORTRAN-IPPB with Manomter
25 10637320040217 IPW-4021 IPW-4021 The VORTRAN®-IPPB allows for single-patient use of an airway clearance device. I The VORTRAN®-IPPB allows for single-patient use of an airway clearance device. It provides high aerosol output with a large nebulizer reservoir. It is easily set-up and more cost effective than a conventional IPPB machine. It is excellent for patients with fluid retention in the lungs. NHJ Device, Positive Pressure Breathing, Intermittent 2 VORTRAN-IPPB with Water Trap
Other products with the same Product Code "BTL"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 10807141000169 100627 MOVES Clamps MOVES THORNHILL RESEARCH INC
2 10807141000152 100626 MOVES Clamps MOVES THORNHILL RESEARCH INC
3 10807141000145 111422 Assy, Power Supply Charger Unit MOVES THORNHILL RESEARCH INC
4 10807141000138 100823 Assy, Battery Pack MOVES THORNHILL RESEARCH INC
5 10807141000121 124847 Assy, MOVES SLC, Accessory Case MOVES SLC THORNHILL RESEARCH INC
6 10807141000114 124846 ASSY, MOVES SLC System in Case MOVES SLC THORNHILL RESEARCH INC
7 10807141000084 124241 Hose, 0.04" x 0.0625", Nafion w/ Label MOVES THORNHILL RESEARCH INC
8 10807141000077 111560 ASSY, MOVES System Case MOVES THORNHILL RESEARCH INC
9 10807141000060 111559 ASSY, MOVES Accessory Case MOVES THORNHILL RESEARCH INC
10 10807141000046 101211 Assy, O2 Mask Breathing Circuit MOVES THORNHILL RESEARCH INC
11 10807141000022 101210 Assy, Ventilator Breathing Circuit MOVES THORNHILL RESEARCH INC
12 10807141000015 100696 Assy, O2 Mask Cartridge MOVES THORNHILL RESEARCH INC
13 10807141000008 100695 Assy, Ventilator Cartridge MOVES THORNHILL RESEARCH INC
14 10641043553282 10-55328 Neo-Tee Tubing Kit MERCURY ENTERPRISES, INC.
15 10641043515068 10-51506 Resusa-Tee T-Piece Resuscitator MERCURY ENTERPRISES, INC.
16 10641043515051 10-51505 Resusa-Tee T-Piece Resuscitator MERCURY ENTERPRISES, INC.
17 10641043515044 10-51504 Resusa-Tee T-Piece Resuscitator MERCURY ENTERPRISES, INC.
18 10641043515037 10-51503 Resusa-Tee T-Piece Resuscitator MERCURY ENTERPRISES, INC.
19 10641043515020 10-51502 Resusa-Tee T-Piece Resuscitator MERCURY ENTERPRISES, INC.
20 10641043515013 10-51501 Resusa-Tee T-Piece Resuscitator MERCURY ENTERPRISES, INC.
21 10641043515006 10-51500 Resusa-Tee T-Piece Resuscitator MERCURY ENTERPRISES, INC.
22 10641043509166 10-50916 Neo-Tee T-Piece Resuscitator Circuit MERCURY ENTERPRISES, INC.
23 10641043509159 10-50915 Neo-Tee T-Piece Resuscitator Circuit MERCURY ENTERPRISES, INC.
24 10641043509142 10-50914 Neo-Tee T-Piece Resuscitator Circuit MERCURY ENTERPRISES, INC.
25 10641043509050 10-50905 Neo-Tee T-Piece Resuscitator Circuit MERCURY ENTERPRISES, INC.
26 10641043509043 10-50904 Neo-Tee T-Piece Resuscitator Circuit MERCURY ENTERPRISES, INC.
27 10641043509036 10-50903 Neo-Tee T-Piece Resuscitator Circuit MERCURY ENTERPRISES, INC.
28 10641043509029 10-50902 Neo-Tee T-Piece Resuscitator Circuit MERCURY ENTERPRISES, INC.
29 10641043509012 10-50901 Neo-Tee T-Piece Resuscitator Circuit MERCURY ENTERPRISES, INC.
30 10641043509005 10-50900 Neo-Tee T-Piece Resuscitator Circuit MERCURY ENTERPRISES, INC.
31 10641043508435 10-50843 Neo-Tee T-Piece Resuscitator MERCURY ENTERPRISES, INC.
32 10641043508428 10-50842 Neo-Tee T-Piece Resuscitator MERCURY ENTERPRISES, INC.
33 10641043508411 10-50841 Neo-Tee T-Piece Resuscitator MERCURY ENTERPRISES, INC.
34 10641043508404 10-50840 Neo-Tee T-Piece Resuscitator MERCURY ENTERPRISES, INC.
35 10641043508398 10-50839 Neo-Tee T-Piece Resuscitator MERCURY ENTERPRISES, INC.
36 10641043508381 10-50838 Neo-Tee T-Piece Resuscitator MERCURY ENTERPRISES, INC.
37 10641043508374 10-50837 Neo-Tee T-Piece Resuscitator MERCURY ENTERPRISES, INC.
38 10641043508367 10-50836 Neo-Tee T-Piece Resuscitator MERCURY ENTERPRISES, INC.
39 10641043508350 10-50835 Neo-Tee T-Piece Resuscitator MERCURY ENTERPRISES, INC.
40 10641043508343 10-50834 Neo-Tee T-Piece Resuscitator MERCURY ENTERPRISES, INC.
41 10641043508336 10-50833 Neo-Tee T-Piece Resuscitator MERCURY ENTERPRISES, INC.
42 10641043508329 10-50832 Neo-Tee T-Piece Resuscitator MERCURY ENTERPRISES, INC.
43 10641043508312 10-50831 Neo-Tee T-Piece Resuscitator MERCURY ENTERPRISES, INC.
44 10641043508305 10-50830 Neo-Tee T-Piece Resuscitator MERCURY ENTERPRISES, INC.
45 10641043508299 10-50829 Neo-Tee T-Piece Resuscitator MERCURY ENTERPRISES, INC.
46 10641043508282 10-50828 Neo-Tee T-Piece Resuscitator MERCURY ENTERPRISES, INC.
47 10641043508275 10-50827 Neo-Tee T-Piece Resuscitator MERCURY ENTERPRISES, INC.
48 10641043508268 10-50826 Neo-Tee T-Piece Resuscitator MERCURY ENTERPRISES, INC.
49 10641043508251 10-50825 Neo-Tee T-Piece Resuscitator MERCURY ENTERPRISES, INC.
50 10641043508244 10-50824 Neo-Tee T-Piece Resuscitator MERCURY ENTERPRISES, INC.