Other products from "NEWDEAL"
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 10381780052944 189220ND The wedge 20° is used to adjust the orientation of the osteotomy LXH ORTHOPEDIC MANUAL SURGICAL INSTRUMENT 1 B-BOP®
2 10381780052937 189215ND The wedge 15° is used to adjust the orientation of the osteotomy LXH ORTHOPEDIC MANUAL SURGICAL INSTRUMENT 1 B-BOP®
3 10381780052920 189210ND The wedge 10° is used to adjust the orientation of the osteotomy LXH ORTHOPEDIC MANUAL SURGICAL INSTRUMENT 1 B-BOP®
4 10381780052067 119135ND The hexagonal cannulated graduated screwdriver axis, with a 4.5mm diameter A-O a The hexagonal cannulated graduated screwdriver axis, with a 4.5mm diameter A-O attachment, is used on a quick coupling handle for hand power to implant or explant the 3.0mm fixation screws. HXX SCREWDRIVER 1 QWIX®
5 10381780052050 119104ND The hexagonal cannulated graduated screwdriver axis, with a 6.0mm diameter tri s The hexagonal cannulated graduated screwdriver axis, with a 6.0mm diameter tri shank attachment, is used on a quick coupling handle to implant and explant the 4.3mm fixation screws. HXX SCREWDRIVER 1 QWIX®
6 10381780052876 119138ND The quick coupling straight handle is used to connect the screwdriver axes with The quick coupling straight handle is used to connect the screwdriver axes with 6.0mm diameter tri shank attachments for motor or hand power to implant or explant 4.3mm screws. LXH ORTHOPEDIC MANUAL SURGICAL INSTRUMENT 1 QWIX®
7 10381780052869 189202ND The holder is used to hold the plate and ease the handling during surgery. KIL POSITIONER, SOCKET 1 B-BOP®
8 10381780125891 REPANTASET REPANTASET The complete PANTA removal set includes instruments to be used for the removal o The complete PANTA removal set includes instruments to be used for the removal of all PANTA nail system. HSB ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES PANTA
9 10381780126546 119940ND The container is used in the transport and the sterilization of the QWIX® associ The container is used in the transport and the sterilization of the QWIX® associated instruments. It includes one combined base with reference 119941ND and one lid with reference 996200ND.The transport and sterilization containers are not intended to maintain sterility. FSM TRAY, SURGICAL, INSTRUMENT 1 QWIX®
10 10381780125877 IPPONINSTP IPPONINSTP The IPP-ON set includes instruments to be used as a guide for Interphalangeal im The IPP-ON set includes instruments to be used as a guide for Interphalangeal implants. The interphalangeal implant is designed to respect anatomical flexion to achieve fixation of interphalangeal arthrodesis of the lesser toes in case of rigid or semi-rigid hammertoe deformity, revision of failed arthroplasty or arthrodesis, and shortening due to length excess of the second toe. HTY PIN, FIXATION, SMOOTH IPP-ON
11 10381780125860 PANTAINSTSET PANTAINSTSET The PANTA nail set inclides instrumentation wich are used as a guide for the imp The PANTA nail set inclides instrumentation wich are used as a guide for the implantation of PANTA Nail system.The PANTA ankle nail is a straight, cannulated intramedullary nail. HSB ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES PANTA
12 10381780064435 LGUNICPINST LGUNICPINST The Large Uni-Clip Staple is a staple so that, by widening the diamond shaped op The Large Uni-Clip Staple is a staple so that, by widening the diamond shaped opening, mechanical deformation leads to narrowing of the interaxis of the two legs. The surgeon can obtain a true compression, adjustable and controlled with many choice of size. The Large Uni-Clip Staple is indicated for fixation of bone fractures or for bone reconstruction. The set includes the staples and instruments. JDR STAPLE, FIXATION, BONE UNI-CLIP
13 10381780064404 HALUINSTSET HALUINSTSET The Hallu-Fix set includes Hallu-Fix S Plates, Hallu-Fix C Plates, screws, and i The Hallu-Fix set includes Hallu-Fix S Plates, Hallu-Fix C Plates, screws, and instruments. The Hallu Plates are low profile titanium plates dedicated to first metatarsophalangeal arthrodesis. The system is intended to be implanted for fixation of fractures, osteotomies or arthrodesis of the first metatarsophalangeal joint. HTY,HRS PIN, FIXATION, SMOOTH,PLATE, FIXATION, BONE HALLU-FIX
14 10381780055976 195200SND 195200SND Titanium alloy sterile variable angle washer belonging to the Newdeal angular lo Titanium alloy sterile variable angle washer belonging to the Newdeal angular locking system fixation. The osteosynthesis screws are fixed to the bone through the plate holes, creating a single implant/screw unit. The system is locked by means of washers drilled into the threaded lipped sockets at the top of each hole, thus blocking each screw head. HWC Screw, fixation, bone SURFIX Alpha
15 10381780055969 195100SND 195100SND Titanium alloy sterile variable angle washer belonging to the Newdeal angular lo Titanium alloy sterile variable angle washer belonging to the Newdeal angular locking system fixation. The osteosynthesis screws are fixed to the bone through the plate holes, creating a single implant/screw unit. The system is locked by means of washers drilled into the threaded lipped sockets at the top of each hole, thus blocking each screw head. HWC Screw, fixation, bone SURFIX Alpha
16 10381780054931 119994ND The tray is part of the container with reference 119990ND, used in the transport The tray is part of the container with reference 119990ND, used in the transport and the sterilization of the LARGE UNI-CLIP® associated instruments and non sterile implants.The transport and sterilization containers are not intended to maintain sterility. FSM TRAY, SURGICAL, INSTRUMENT 1 LARGE UNI-CLIP®
17 10381780052777 213820SND 213820SND The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, mechanical deformation leads to narrowing of the interaxis of the two legs. The surgeon can obtain a true compression, adjustable and controlled with many choice of sizes (11, 12, 13 or 15mm interaxis, and lengths vary from 13 to 20mm). The UNI-CLIP STAPLE is made from Stainless Steel and it is indicated for fixation of bone fractures or for bone reconstruction. It is delivered sterile. JDR STAPLE, FIXATION, BONE UNI-CLIP
18 10381780052760 213820ND 213820ND The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, mechanical deformation leads to narrowing of the interaxis of the two legs. The surgeon can obtain a true compression, adjustable and controlled with many choice of sizes (11, 12, 13 or 15mm interaxis, and lengths vary from 13 to 20mm). The UNI-CLIP STAPLE is made from Stainless Steel and it is indicated for fixation of bone fractures or for bone reconstruction. It is delivered non sterile. JDR STAPLE, FIXATION, BONE UNI-CLIP
19 10381780052753 213512SND 213512SND The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, mechanical deformation leads to narrowing of the interaxis of the two legs. The surgeon can obtain a true compression, adjustable and controlled with many choice of sizes (11, 12, 13 or 15mm interaxis, and lengths vary from 13 to 20mm). The UNI-CLIP STAPLE is made from Stainless Steel and it is indicated for fixation of bone fractures or for bone reconstruction. It is delivered sterile. JDR STAPLE, FIXATION, BONE UNI-CLIP
20 10381780052210 189204ND The Snap-Off screwdriver tip with AO attachment is used to implant or explant screws. HXX SCREWDRIVER 1 B-BOP®
21 10381780052746 213512ND 213512ND The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, mechanical deformation leads to narrowing of the interaxis of the two legs. The surgeon can obtain a true compression, adjustable and controlled with many choice of sizes (11, 12, 13 or 15mm interaxis, and lengths vary from 13 to 20mm). The UNI-CLIP STAPLE is made from Stainless Steel and it is indicated for fixation of bone fractures or for bone reconstruction. It is delivered non sterile. JDR STAPLE, FIXATION, BONE 2 UNI-CLIP
22 10381780052739 213317SND 213317SND The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, mechanical deformation leads to narrowing of the interaxis of the two legs. The surgeon can obtain a true compression, adjustable and controlled with many choice of sizes (11, 12, 13 or 15mm interaxis, and lengths vary from 13 to 20mm). The UNI-CLIP STAPLE is made from Stainless Steel and it is indicated for fixation of bone fractures or for bone reconstruction. It is delivered sterile. JDR STAPLE, FIXATION, BONE UNI-CLIP
23 10381780052722 213317ND 213317ND The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, mechanical deformation leads to narrowing of the interaxis of the two legs. The surgeon can obtain a true compression, adjustable and controlled with many choice of sizes (11, 12, 13 or 15mm interaxis, and lengths vary from 13 to 20mm). The UNI-CLIP STAPLE is made from Stainless Steel and it is indicated for fixation of bone fractures or for bone reconstruction. It is delivered non sterile. JDR STAPLE, FIXATION, BONE UNI-CLIP
24 10381780052715 213316SND 213316SND The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, mechanical deformation leads to narrowing of the interaxis of the two legs. The surgeon can obtain a true compression, adjustable and controlled with many choice of sizes (11, 12, 13 or 15mm interaxis, and lengths vary from 13 to 20mm). The UNI-CLIP STAPLE is made from Stainless Steel and it is indicated for fixation of bone fractures or for bone reconstruction. It is delivered sterile. JDR STAPLE, FIXATION, BONE UNI-CLIP
25 10381780052708 213316ND 213316ND The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, mechanical deformation leads to narrowing of the interaxis of the two legs. The surgeon can obtain a true compression, adjustable and controlled with many choice of sizes (11, 12, 13 or 15mm interaxis, and lengths vary from 13 to 20mm). The UNI-CLIP STAPLE is made from Stainless Steel and it is indicated for fixation of bone fractures or for bone reconstruction. It is delivered non sterile. JDR STAPLE, FIXATION, BONE UNI-CLIP
26 10381780052692 213315SND 213315SND The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, mechanical deformation leads to narrowing of the interaxis of the two legs. The surgeon can obtain a true compression, adjustable and controlled with many choice of sizes (11, 12, 13 or 15mm interaxis, and lengths vary from 13 to 20mm). The UNI-CLIP STAPLE is made from Stainless Steel and it is indicated for fixation of bone fractures or for bone reconstruction. It is delivered sterile. JDR STAPLE, FIXATION, BONE UNI-CLIP
27 10381780052685 213315ND 213315ND The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, mechanical deformation leads to narrowing of the interaxis of the two legs. The surgeon can obtain a true compression, adjustable and controlled with many choice of sizes (11, 12, 13 or 15mm interaxis, and lengths vary from 13 to 20mm). The UNI-CLIP STAPLE is made from Stainless Steel and it is indicated for fixation of bone fractures or for bone reconstruction. It is delivered non sterile. JDR STAPLE, FIXATION, BONE UNI-CLIP
28 10381780052678 213314SND 213314SND The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, mechanical deformation leads to narrowing of the interaxis of the two legs. The surgeon can obtain a true compression, adjustable and controlled with many choice of sizes (11, 12, 13 or 15mm interaxis, and lengths vary from 13 to 20mm). The UNI-CLIP STAPLE is made from Stainless Steel and it is indicated for fixation of bone fractures or for bone reconstruction. It is delivered sterile. JDR STAPLE, FIXATION, BONE UNI-CLIP
29 10381780052661 213314ND 213314ND The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, mechanical deformation leads to narrowing of the interaxis of the two legs. The surgeon can obtain a true compression, adjustable and controlled with many choice of sizes (11, 12, 13 or 15mm interaxis, and lengths vary from 13 to 20mm). The UNI-CLIP STAPLE is made from Stainless Steel and it is indicated for fixation of bone fractures or for bone reconstruction. It is delivered non sterile. JDR STAPLE, FIXATION, BONE 2 UNI-CLIP
30 10381780052654 213313SND 213313SND The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, mechanical deformation leads to narrowing of the interaxis of the two legs. The surgeon can obtain a true compression, adjustable and controlled with many choice of sizes (11, 12, 13 or 15mm interaxis, and lengths vary from 13 to 20mm). The UNI-CLIP STAPLE is made from Stainless Steel and it is indicated for fixation of bone fractures or for bone reconstruction. It is delivered sterile. JDR STAPLE, FIXATION, BONE UNI-CLIP
31 10381780052647 213313ND 213313ND The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, mechanical deformation leads to narrowing of the interaxis of the two legs. The surgeon can obtain a true compression, adjustable and controlled with many choice of sizes (11, 12, 13 or 15mm interaxis, and lengths vary from 13 to 20mm). The UNI-CLIP STAPLE is made from Stainless Steel and it is indicated for fixation of bone fractures or for bone reconstruction. It is delivered non sterile. JDR STAPLE, FIXATION, BONE 2 UNI-CLIP
32 10381780052630 213217SND 213217SND The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, mechanical deformation leads to narrowing of the interaxis of the two legs. The surgeon can obtain a true compression, adjustable and controlled with many choice of sizes (11, 12, 13 or 15mm interaxis, and lengths vary from 13 to 20mm). The UNI-CLIP STAPLE is made from Stainless Steel and it is indicated for fixation of bone fractures or for bone reconstruction. It is delivered sterile. JDR STAPLE, FIXATION, BONE UNI-CLIP
33 10381780052623 213217ND 213217ND The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, mechanical deformation leads to narrowing of the interaxis of the two legs. The surgeon can obtain a true compression, adjustable and controlled with many choice of sizes (11, 12, 13 or 15mm interaxis, and lengths vary from 13 to 20mm). The UNI-CLIP STAPLE is made from Stainless Steel and it is indicated for fixation of bone fractures or for bone reconstruction. It is delivered non sterile. JDR STAPLE, FIXATION, BONE UNI-CLIP
34 10381780052616 213216SND 213216SND The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, mechanical deformation leads to narrowing of the interaxis of the two legs. The surgeon can obtain a true compression, adjustable and controlled with many choice of sizes (11, 12, 13 or 15mm interaxis, and lengths vary from 13 to 20mm). The UNI-CLIP STAPLE is made from Stainless Steel and it is indicated for fixation of bone fractures or for bone reconstruction. It is delivered sterile. JDR STAPLE, FIXATION, BONE UNI-CLIP
35 10381780052609 213216ND 213216ND The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, mechanical deformation leads to narrowing of the interaxis of the two legs. The surgeon can obtain a true compression, adjustable and controlled with many choice of sizes (11, 12, 13 or 15mm interaxis, and lengths vary from 13 to 20mm). The UNI-CLIP STAPLE is made from Stainless Steel and it is indicated for fixation of bone fractures or for bone reconstruction. It is delivered non sterile. JDR STAPLE, FIXATION, BONE UNI-CLIP
36 10381780052593 213215SND 213215SND The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, mechanical deformation leads to narrowing of the interaxis of the two legs. The surgeon can obtain a true compression, adjustable and controlled with many choice of sizes (11, 12, 13 or 15mm interaxis, and lengths vary from 13 to 20mm). The UNI-CLIP STAPLE is made from Stainless Steel and it is indicated for fixation of bone fractures or for bone reconstruction. It is delivered sterile. JDR STAPLE, FIXATION, BONE UNI-CLIP
37 10381780052586 213215ND 213215ND The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, mechanical deformation leads to narrowing of the interaxis of the two legs. The surgeon can obtain a true compression, adjustable and controlled with many choice of sizes (11, 12, 13 or 15mm interaxis, and lengths vary from 13 to 20mm). The UNI-CLIP STAPLE is made from Stainless Steel and it is indicated for fixation of bone fractures or for bone reconstruction. It is delivered non sterile. JDR STAPLE, FIXATION, BONE 2 UNI-CLIP
38 10381780052579 213214SND 213214SND The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, mechanical deformation leads to narrowing of the interaxis of the two legs. The surgeon can obtain a true compression, adjustable and controlled with many choice of sizes (11, 12, 13 or 15mm interaxis, and lengths vary from 13 to 20mm). The UNI-CLIP STAPLE is made from Stainless Steel and it is indicated for fixation of bone fractures or for bone reconstruction. It is delivered sterile. JDR STAPLE, FIXATION, BONE UNI-CLIP
39 10381780052562 213214ND 213214ND The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, mechanical deformation leads to narrowing of the interaxis of the two legs. The surgeon can obtain a true compression, adjustable and controlled with many choice of sizes (11, 12, 13 or 15mm interaxis, and lengths vary from 13 to 20mm). The UNI-CLIP STAPLE is made from Stainless Steel and it is indicated for fixation of bone fractures or for bone reconstruction. It is delivered non sterile. JDR STAPLE, FIXATION, BONE 2 UNI-CLIP
40 10381780052555 213213SND 213213SND The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, mechanical deformation leads to narrowing of the interaxis of the two legs. The surgeon can obtain a true compression, adjustable and controlled with many choice of sizes (11, 12, 13 or 15mm interaxis, and lengths vary from 13 to 20mm). The UNI-CLIP STAPLE is made from Stainless Steel and it is indicated for fixation of bone fractures or for bone reconstruction. It is delivered sterile. JDR STAPLE, FIXATION, BONE UNI-CLIP
41 10381780052548 213213ND 213213ND The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, mechanical deformation leads to narrowing of the interaxis of the two legs. The surgeon can obtain a true compression, adjustable and controlled with many choice of sizes (11, 12, 13 or 15mm interaxis, and lengths vary from 13 to 20mm). The UNI-CLIP STAPLE is made from Stainless Steel and it is indicated for fixation of bone fractures or for bone reconstruction. It is delivered non sterile. JDR STAPLE, FIXATION, BONE 2 UNI-CLIP
42 10381780052531 213117SND 213117SND The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, mechanical deformation leads to narrowing of the interaxis of the two legs. The surgeon can obtain a true compression, adjustable and controlled with many choice of sizes (11, 12, 13 or 15mm interaxis, and lengths vary from 13 to 20mm). The UNI-CLIP STAPLE is made from Stainless Steel and it is indicated for fixation of bone fractures or for bone reconstruction. It is delivered sterile. JDR STAPLE, FIXATION, BONE UNI-CLIP
43 10381780052524 213117ND 213117ND The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, mechanical deformation leads to narrowing of the interaxis of the two legs. The surgeon can obtain a true compression, adjustable and controlled with many choice of sizes (11, 12, 13 or 15mm interaxis, and lengths vary from 13 to 20mm). The UNI-CLIP STAPLE is made from Stainless Steel and it is indicated for fixation of bone fractures or for bone reconstruction. It is delivered non sterile. JDR STAPLE, FIXATION, BONE UNI-CLIP
44 10381780052517 213116SND 213116SND The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, mechanical deformation leads to narrowing of the interaxis of the two legs. The surgeon can obtain a true compression, adjustable and controlled with many choice of sizes (11, 12, 13 or 15mm interaxis, and lengths vary from 13 to 20mm). The UNI-CLIP STAPLE is made from Stainless Steel and it is indicated for fixation of bone fractures or for bone reconstruction. It is delivered sterile. JDR STAPLE, FIXATION, BONE UNI-CLIP
45 10381780052500 213116ND 213116ND The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, mechanical deformation leads to narrowing of the interaxis of the two legs. The surgeon can obtain a true compression, adjustable and controlled with many choice of sizes (11, 12, 13 or 15mm interaxis, and lengths vary from 13 to 20mm). The UNI-CLIP STAPLE is made from Stainless Steel and it is indicated for fixation of bone fractures or for bone reconstruction. It is delivered non sterile. JDR STAPLE, FIXATION, BONE 2 UNI-CLIP
46 10381780052494 213115SND 213115SND The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, mechanical deformation leads to narrowing of the interaxis of the two legs. The surgeon can obtain a true compression, adjustable and controlled with many choice of sizes (11, 12, 13 or 15mm interaxis, and lengths vary from 13 to 20mm). The UNI-CLIP STAPLE is made from Stainless Steel and it is indicated for fixation of bone fractures or for bone reconstruction. It is delivered sterile. JDR STAPLE, FIXATION, BONE UNI-CLIP
47 10381780052487 213115ND 213115ND The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, mechanical deformation leads to narrowing of the interaxis of the two legs. The surgeon can obtain a true compression, adjustable and controlled with many choice of sizes (11, 12, 13 or 15mm interaxis, and lengths vary from 13 to 20mm). The UNI-CLIP STAPLE is made from Stainless Steel and it is indicated for fixation of bone fractures or for bone reconstruction. It is delivered non sterile. JDR STAPLE, FIXATION, BONE 2 UNI-CLIP
48 10381780052470 213114SND 213114SND The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, mechanical deformation leads to narrowing of the interaxis of the two legs. The surgeon can obtain a true compression, adjustable and controlled with many choice of sizes (11, 12, 13 or 15mm interaxis, and lengths vary from 13 to 20mm). The UNI-CLIP STAPLE is made from Stainless Steel and it is indicated for fixation of bone fractures or for bone reconstruction. It is delivered sterile. JDR STAPLE, FIXATION, BONE UNI-CLIP
49 10381780052463 213114ND 213114ND The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, mechanical deformation leads to narrowing of the interaxis of the two legs. The surgeon can obtain a true compression, adjustable and controlled with many choice of sizes (11, 12, 13 or 15mm interaxis, and lengths vary from 13 to 20mm). The UNI-CLIP STAPLE is made from Stainless Steel and it is indicated for fixation of bone fractures or for bone reconstruction. It is delivered non sterile. JDR STAPLE, FIXATION, BONE 2 UNI-CLIP
50 10381780052456 213113SND 213113SND The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, The UNI-CLIP STAPLE is designed so that, by widening the diamond shaped opening, mechanical deformation leads to narrowing of the interaxis of the two legs. The surgeon can obtain a true compression, adjustable and controlled with many choice of sizes (11, 12, 13 or 15mm interaxis, and lengths vary from 13 to 20mm). The UNI-CLIP STAPLE is made from Stainless Steel and it is indicated for fixation of bone fractures or for bone reconstruction. It is delivered sterile. JDR STAPLE, FIXATION, BONE UNI-CLIP
Other products with the same Product Code "HWT"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 00643169840676 X0716012 ROD TEMPLATE X0716012 50CM N/A MEDTRONIC SOFAMOR DANEK, INC.
2 00643169328617 3001919 TEMPLATE 3001919 ZEVO 19MM 1 LVL N/A MEDTRONIC SOFAMOR DANEK, INC.
3 00643169328600 3001917 TEMPLATE 3001917 ZEVO 17MM 1 LVL N/A MEDTRONIC SOFAMOR DANEK, INC.
4 00643169328594 3001915 TEMPLATE 3001915 ZEVO 15MM 1 LVL N/A MEDTRONIC SOFAMOR DANEK, INC.
5 00643169328587 3003959 TEMPLATE 3003959 ZEVO 59MM 3 LVL N/A MEDTRONIC SOFAMOR DANEK, INC.
6 00643169328570 3005908 TEMPLATE 3005908 ZEVO 108MM 5 LVL N/A MEDTRONIC SOFAMOR DANEK, INC.
7 00643169328563 3005905 TEMPLATE 3005905 ZEVO 105MM 5 LVL N/A MEDTRONIC SOFAMOR DANEK, INC.
8 00643169328556 3005900 TEMPLATE 3005900 ZEVO 100MM 5 LVL N/A MEDTRONIC SOFAMOR DANEK, INC.
9 00643169328549 3005995 TEMPLATE 3005995 ZEVO 95MM 5 LVL N/A MEDTRONIC SOFAMOR DANEK, INC.
10 00643169328532 3005990 Template 3005990 ZEVO 90mm 5 lvl N/A MEDTRONIC SOFAMOR DANEK, INC.
11 00643169328525 3005985 TEMPLATE 3005985 ZEVO 85MM 5 LVL N/A MEDTRONIC SOFAMOR DANEK, INC.
12 00643169662841 4362230 TEMPLATE 4362230 22MM/30MM TEMPLATE Medtronic Reusable Instruments MEDTRONIC SOFAMOR DANEK, INC.
13 00643169662834 4362025 TEMPLATE 4362025 20MM/25MM TEMPLATE Medtronic Reusable Instruments MEDTRONIC SOFAMOR DANEK, INC.
14 00643169662827 4361316 TEMPLATE 4361316 13MM/16MM TEMPLATE Medtronic Reusable Instruments MEDTRONIC SOFAMOR DANEK, INC.
15 00643169662810 4360045 TEMPLATE 4360045 45MM EXTENDED TEMPLATE Medtronic Reusable Instruments MEDTRONIC SOFAMOR DANEK, INC.
16 00643169662803 4360040 TEMPLATE 4360040 40MM EXTENDED TEMPLATE Medtronic Reusable Instruments MEDTRONIC SOFAMOR DANEK, INC.
17 00643169662797 4360035 TEMPLATE 4360035 35MM EXTENDED TEMPLATE Medtronic Reusable Instruments MEDTRONIC SOFAMOR DANEK, INC.
18 00643169662780 4360030 TEMPLATE 4360030 30MM EXTENDED TEMPLATE Medtronic Reusable Instruments MEDTRONIC SOFAMOR DANEK, INC.
19 00643169328518 3005981 TEMPLATE 3005981 ZEVO 81MM 5 LVL N/A MEDTRONIC SOFAMOR DANEK, INC.
20 00643169328501 3005979 TEMPLATE 3005979 ZEVO 79MM 5 LVL N/A MEDTRONIC SOFAMOR DANEK, INC.
21 00643169328495 3005977 TEMPLATE 3005977 ZEVO 77MM 5 LVL N/A MEDTRONIC SOFAMOR DANEK, INC.
22 00643169328488 3005975 TEMPLATE 3005975 ZEVO 75MM 5 LVL N/A MEDTRONIC SOFAMOR DANEK, INC.
23 00643169328471 3003955 TEMPLATE 3003955 ZEVO 55MM 3 LVL N/A MEDTRONIC SOFAMOR DANEK, INC.
24 00643169328464 3004989 TEMPLATE 3004989 ZEVO 89MM 4 LVL N/A MEDTRONIC SOFAMOR DANEK, INC.
25 00643169328457 3004987 TEMPLATE 3004987 ZEVO 87MM 4 LVL N/A MEDTRONIC SOFAMOR DANEK, INC.
26 00643169328440 3004985 TEMPLATE 3004985 ZEVO 85MM 4 LVL N/A MEDTRONIC SOFAMOR DANEK, INC.
27 00643169328433 3004983 TEMPLATE 3004983 ZEVO 83MM 4 LVL N/A MEDTRONIC SOFAMOR DANEK, INC.
28 00643169328426 3004981 TEMPLATE 3004981 ZEVO 81MM 4 LVL N/A MEDTRONIC SOFAMOR DANEK, INC.
29 00643169328419 3004979 TEMPLATE 3004979 ZEVO 79MM 4 LVL N/A MEDTRONIC SOFAMOR DANEK, INC.
30 00643169328402 3004977 TEMPLATE 3004977 ZEVO 77MM 4 LVL N/A MEDTRONIC SOFAMOR DANEK, INC.
31 00643169328396 3004975 TEMPLATE 3004975 ZEVO 75MM 4 LVL N/A MEDTRONIC SOFAMOR DANEK, INC.
32 00643169328389 3004973 TEMPLATE 3004973 ZEVO 73MM 4 LVL N/A MEDTRONIC SOFAMOR DANEK, INC.
33 00643169328372 3004971 TEMPLATE 3004971 ZEVO 71MM 4 LVL N/A MEDTRONIC SOFAMOR DANEK, INC.
34 00643169328365 3004969 TEMPLATE 3004969 ZEVO 69MM 4 LVL N/A MEDTRONIC SOFAMOR DANEK, INC.
35 00643169328358 3004967 TEMPLATE 3004967 ZEVO 67MM 4 LVL N/A MEDTRONIC SOFAMOR DANEK, INC.
36 00643169328341 3004965 TEMPLATE 3004965 ZEVO 65MM 4 LVL N/A MEDTRONIC SOFAMOR DANEK, INC.
37 00643169328334 3003971 TEMPLATE 3003971 ZEVO 71MM 3 LVL N/A MEDTRONIC SOFAMOR DANEK, INC.
38 00643169328327 3003969 TEMPLATE 3003969 ZEVO 69MM 3 LVL N/A MEDTRONIC SOFAMOR DANEK, INC.
39 00643169328310 3003967 TEMPLATE 3003967 ZEVO 67MM 3 LVL N/A MEDTRONIC SOFAMOR DANEK, INC.
40 00643169591431 EX0115004 BAR EX0115004 T N/A MEDTRONIC SOFAMOR DANEK, INC.
41 00643169589902 7372575 TEMPLATE 7372575 75MM PLATE TEMPLATE N/A MEDTRONIC SOFAMOR DANEK, INC.
42 00643169589896 7372572 TEMPLATE 7372572 72.5MM PLATE TEMPLATE N/A MEDTRONIC SOFAMOR DANEK, INC.
43 00643169589841 7372560 TEMPLATE 7372560 60MM PLATE TEMPLATE N/A MEDTRONIC SOFAMOR DANEK, INC.
44 00643169589834 7372555 TEMPLATE 7372555 55MM PLATE TEMPLATE N/A MEDTRONIC SOFAMOR DANEK, INC.
45 00643169589827 7372545 TEMPLATE 7372545 45MM PLATE TEMPLATE ATLANTIS ESSENTIALS™ Anterior Cervical Plate System MEDTRONIC SOFAMOR DANEK, INC.
46 00643169589810 7372542 TEMPLATE 7372542 42.5MM PLATE TEMPLATE ATLANTIS ESSENTIALS™ Anterior Cervical Plate System MEDTRONIC SOFAMOR DANEK, INC.
47 00643169589803 7372540 TEMPLATE 7372540 40MM PLATE TEMPLATE ATLANTIS ESSENTIALS™ Anterior Cervical Plate System MEDTRONIC SOFAMOR DANEK, INC.
48 00643169589797 7372537 TEMPLATE 7372537 37.5MM PLATE TEMPLATE N/A MEDTRONIC SOFAMOR DANEK, INC.
49 00643169589780 7372535 TEMPLATE 7372535 35MM PLATE TEMPLATE ATLANTIS ESSENTIALS™ Anterior Cervical Plate System MEDTRONIC SOFAMOR DANEK, INC.
50 00643169589773 7372527 TEMPLATE 7372527 27.5MM PLATE TEMPLATE N/A MEDTRONIC SOFAMOR DANEK, INC.